MIB Viewer

A3COM-HUAWEI-ENTITY-EXT-MIB

111 objects
The private MIB file includes the general extent information of the device.
OIDNameAccessStatusDescription
1.3.6.1.4.1.43.45.1.10.2.6Identityh3cEntityExtendThe private MIB file includes the general extent information of the device.
1.3.6.1.4.1.43.45.1.10.2.6.1Nodeh3cEntityExtObjects
1.3.6.1.4.1.43.45.1.10.2.6.1.1Nodeh3cEntityExtState
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1Tableh3cEntityExtStateTablenot-accessiblecurrentThis table contains one row per physical entity, There is always at least one row for an 'overall' physical entity. The information in each row may be not incl…
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1Rowh3cEntityExtStateEntrynot-accessiblecurrentThe information about a particular physical entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.1Columnh3cEntityExtPhysicalIndexaccessible-for-notifycurrentThe index of h3cEntityExtStateTable. This index is identical to entPhysicalIndex in ENTITY-MIB
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.2Columnh3cEntityExtAdminStatusread-writecurrentThe administrative state for this object.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.3Columnh3cEntityExtOperStatusread-onlycurrentThe operate state for this object.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.4Columnh3cEntityExtStandbyStatusread-onlycurrentThis object is used for monitoring standby status. Not all entities support this object.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.5Columnh3cEntityExtAlarmLightread-onlycurrentThe alarm status for this entity. It does not include the severity of alarms raised on child components. In this condition, there will be a alarm light on the …
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.6Columnh3cEntityExtCpuUsageread-onlycurrentThe CPU usage for this entity. Generally, the CPU usage will calculate the overall CPU usage on the entity, and it is not sensible with the number of CPU on th…
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.7Columnh3cEntityExtCpuUsageThresholdread-writecurrentThe threshold for the CPU usage. When the CPU usage exceeds the threshold, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.8Columnh3cEntityExtMemUsageread-onlycurrentThe memory usage for the entity. This object indicates what percent of memory are used.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.9Columnh3cEntityExtMemUsageThresholdread-writecurrentThe threshold for the Memory usage, When the memory usage exceeds the threshold, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.10Columnh3cEntityExtMemSizeread-onlycurrentThe size of memory for the entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.11Columnh3cEntityExtUpTimeread-onlycurrentThe uptime for the entity. The meaning of uptime is when the entity is up, and the value of the object will add 1 seconds while the entity is running.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.12Columnh3cEntityExtTemperatureread-onlycurrentThe temperature for the entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.13Columnh3cEntityExtTemperatureThresholdread-writecurrentThe threshold for the temperature. When the temperature exceeds the threshold, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.14Columnh3cEntityExtVoltageread-onlycurrentThe voltage for the entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.15Columnh3cEntityExtVoltageLowThresholdread-writecurrentThe low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.16Columnh3cEntityExtVoltageHighThresholdread-writecurrentThe high-threshold for the voltage. When voltage greater than high-threshold, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.17Columnh3cEntityExtCriticalTemperatureThresholdread-writecurrentThe threshold for the critical Temperature. When temperature exceeds the critical temperature, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.18Columnh3cEntityExtMacAddressread-onlycurrentMAC Address of the entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.19Columnh3cEntityExtErrorStatusread-onlycurrentIndicate the error state of this entity object. Now it only supports Port, general power supply, RPS power supply and board/Subcard. It may have one of these v…
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.20Columnh3cEntityExtCpuMaxUsageread-onlycurrentThe maximal CPU usage for the entity in the period of time.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.21Columnh3cEntityExtLowerTemperatureThresholdread-writecurrentThe threshold for the lower Temperature. When temperature runs under the threshold, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.22Columnh3cEntityExtShutdownTemperatureThresholdread-writecurrentThe threshold for the shutdown Temperature. When temperature exceeds the threshold, a notification will be sent and the entity will be shutdown.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.23Columnh3cEntityExtPhyMemSizeread-onlycurrentThe memory size of entity. This is the physical attribute of entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.24Columnh3cEntityExtPhyCpuFrequencyread-onlycurrentThe CPU frequency of entity. Unit of measure is MHZ.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.25Columnh3cEntityExtFirstUsedDateread-onlycurrentThe first used date of the entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.26Columnh3cEntityExtCpuAvgUsageread-onlycurrentThe average CPU usage for the entity in a period of time.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.27Columnh3cEntityExtMemAvgUsageread-onlycurrentThe average memory usage for the entity in a period of time.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.28Columnh3cEntityExtMemTyperead-onlycurrentThe memory type of entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.29Columnh3cEntityExtCriticalLowerTemperatureThresholdread-writecurrentThe threshold for the critical Temperature. When temperature exceeds the critical lower temperature, a notification will be sent.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.30Columnh3cEntityExtShutdownLowerTemperatureThresholdread-writecurrentThe threshold for the shutdown Temperature. When temperature exceeds the lower threshold, a notification will be sent and the entity will be shutdown.
1.3.6.1.4.1.43.45.1.10.2.6.1.1.1.1.31Columnh3cEntityExtCpuUsageRecoverThresholdread-writecurrentThe recover threshold for the CPU usage. When the CPU usage falls down to the threshold, a notification is sent. The h3cEntityExtCpuUsageRecoverThreshold must …
1.3.6.1.4.1.43.45.1.10.2.6.1.2Nodeh3cEntityExtManu
1.3.6.1.4.1.43.45.1.10.2.6.1.2.1Tableh3cEntityExtManuTablenot-accessiblecurrentThe table about device manufacture information.
1.3.6.1.4.1.43.45.1.10.2.6.1.2.1.1Rowh3cEntityExtManuEntrynot-accessiblecurrentThe device manufacture information about a particular physical entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.2.1.1.1Columnh3cEntityExtManuPhysicalIndexaccessible-for-notifycurrentThe index of h3cEntityExtManuTable. This index is identical to entPhysicalIndex in ENTITY-MIB.
1.3.6.1.4.1.43.45.1.10.2.6.1.2.1.1.2Columnh3cEntityExtManuSerialNumread-onlycurrentManufacture serial number. The manufacture serial number of the entity such as chassis, module, and so on. It is got from the device when manufacturing. For lo…
1.3.6.1.4.1.43.45.1.10.2.6.1.2.1.1.3Columnh3cEntityExtManuBuildInforead-onlycurrentDevice version information. The device version information of the entity such as chassis, module, and so on. It consists of software version information and ha…
1.3.6.1.4.1.43.45.1.10.2.6.1.2.1.1.4Columnh3cEntityExtManuBOMread-onlycurrentDevice BOM code. The device BOM code of the entity such as chassis, module, and so on. It is the component code of ERP system, which can be disassembled from d…
1.3.6.1.4.1.43.45.1.10.2.6.1.2.1.1.5Columnh3cEntityExtMacAddressCountread-onlycurrentMAC address count. The count of MAC addresses of the entity, such as chassis, module, or port, and so on.
1.3.6.1.4.1.43.45.1.10.2.6.1.3Nodeh3cEntityExtPower
1.3.6.1.4.1.43.45.1.10.2.6.1.3.1Tableh3cEntityExtPowerTablenot-accessiblecurrentThis table describes the power information of all the physical entity on the device, such as the fans, the subcards, the boards, etc.
1.3.6.1.4.1.43.45.1.10.2.6.1.3.1.1Rowh3cEntityExtPowerEntrynot-accessiblecurrentThe entity power information about a particular physical entity.
1.3.6.1.4.1.43.45.1.10.2.6.1.3.1.1.1Columnh3cEntityExtPowerPhysicalIndexaccessible-for-notifycurrentThe index of h3cEntityExtPowerTable. This index is identical to entPhysicalIndex in ENTITY-MIB.
1.3.6.1.4.1.43.45.1.10.2.6.1.3.1.1.2Columnh3cEntityExtNominalPowerread-onlycurrentThe nominal power of the entity expressed in milliWatts.
1.3.6.1.4.1.43.45.1.10.2.6.1.3.1.1.3Columnh3cEntityExtCurrentPowerread-onlycurrentThe measured usage power of the entity expressed in milliWatts.
1.3.6.1.4.1.43.45.1.10.2.6.1.3.1.1.4Columnh3cEntityExtAveragePowerread-writecurrentThe average power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to t…
1.3.6.1.4.1.43.45.1.10.2.6.1.3.1.1.5Columnh3cEntityExtPeakPowerread-writecurrentThe peak power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this…
1.3.6.1.4.1.43.45.1.10.2.6.1.4Nodeh3cProcessObjects
1.3.6.1.4.1.43.45.1.10.2.6.1.4.1Tableh3cProcessTablenot-accessiblecurrentThe Table describes the information about a particular process, namely a task.
1.3.6.1.4.1.43.45.1.10.2.6.1.4.1.1Rowh3cProcessEntrynot-accessiblecurrentThe information about a particular process, namely a task.
1.3.6.1.4.1.43.45.1.10.2.6.1.4.1.1.1Columnh3cProcessIDread-onlycurrentThis object indicates the identifier of process, namely task ID in system.
1.3.6.1.4.1.43.45.1.10.2.6.1.4.1.1.2Columnh3cProcessNameread-onlycurrentThis object indicates the process name.
1.3.6.1.4.1.43.45.1.10.2.6.1.4.1.1.3Columnh3cProcessUtil5Minread-onlycurrentThis object provides a general idea of how busy a process caused the processor to be over a 5 minute period. The ratio is calculated by the overall CPU usage c…
1.3.6.1.4.1.43.45.1.10.2.6.2Nodeh3cEntityExtTraps
1.3.6.1.4.1.43.45.1.10.2.6.2.0Nodeh3cEntityExtTrapsPrefix
1.3.6.1.4.1.43.45.1.10.2.6.2.0.1Notificationh3cEntityExtTemperatureThresholdNotificationcurrentThe h3cEntityExtTemperatureThresholdNotification indicates the temperature exceeded the threshold. In this condition, user should check the status and the envi…
1.3.6.1.4.1.43.45.1.10.2.6.2.0.2Notificationh3cEntityExtVoltageLowThresholdNotificationcurrentThe h3cEntityExtVoltageLowThresholdNotification indicates the voltage is lower than the threshold. If the voltage is lower too much than the entity needs, the …
1.3.6.1.4.1.43.45.1.10.2.6.2.0.3Notificationh3cEntityExtVoltageHighThresholdNotificationcurrentThe h3cEntityExtVoltageHighThresholdNotification indicates the voltage is higher than the threshold. If the voltage is higher too much than the entity needs, T…
1.3.6.1.4.1.43.45.1.10.2.6.2.0.4Notificationh3cEntityExtCpuUsageThresholdNotficationcurrentThe h3cEntityExtCpuUsageThresholdNotfication indicates the entity is overloaded.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.5Notificationh3cEntityExtMemUsageThresholdNotificationcurrentThe h3cEntityExtMemUsageThresholdNotification indicates the entity is overloaded.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.6Notificationh3cEntityExtOperEnabledcurrentThe trap indicates the entity is operable at present.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.7Notificationh3cEntityExtOperDisabledcurrentThe trap indicates the entity is not operable at present.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.8Notificationh3cEntityExtCriticalTemperatureThresholdNotificationcurrentThe h3cEntityExtCriticalTemperatureThresholdNotification indicates the temperature exceeds the critical temperature. In this condition, user should check the s…
1.3.6.1.4.1.43.45.1.10.2.6.2.0.9Notificationh3cEntityExtSFPAlarmOncurrentThe trap is generated when the SFP module fails or runs abnormally for some particular reason.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.10Notificationh3cEntityExtSFPAlarmOffcurrentThe trap is generated when the SFP module restores to normal status.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.11Notificationh3cEntityExtSFPPhonycurrentThis module is NOT sold by authorized manufacturer. The normal function of the device or assume the maintenance responsibility thereof will NOT be guaranteed. …
1.3.6.1.4.1.43.45.1.10.2.6.2.0.12Notificationh3cEntityInsertcurrentThe trap is generated when a removeable entity inserting to device.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.13Notificationh3cEntityRemovecurrentThe trap is generated when a removeable entity removing from device.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.14Notificationh3cEntityExtForcedPowerOffcurrentThe trap indicates the entity is forced to power off.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.15Notificationh3cEntityExtForcedPowerOncurrentThe trap indicates the entity is forced to power on.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.16Notificationh3cEntityExtFaultAlarmOncurrentThe trap indicates a fault occures on the specified entity.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.17Notificationh3cEntityExtFaultAlarmOffcurrentThe trap indicates a fault disappears on the specified entity.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.18Notificationh3cEntityExtResourceLackcurrentThe trap indicates that a kind of resource is not enough on the specified entity.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.19Notificationh3cEntityExtResourceEnoughcurrentThe trap indicates that the entity recovers from the status of no enough resource.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.20Notificationh3cEntityExtTemperatureLowercurrentThe trap indicates the temperature of a specified entity is under the lower threshold. In this condition, user should check the status and the environment of t…
1.3.6.1.4.1.43.45.1.10.2.6.2.0.21Notificationh3cEntityExtTemperatureTooUpcurrentThe trap indicates the temperature of a specified entity exceeded the shutdown threshold. In this condition, user should check the status and the environment o…
1.3.6.1.4.1.43.45.1.10.2.6.2.0.22Notificationh3cEntityExtTemperatureNormalcurrentThe trap indicates the temperature of a specified entity recover from abnormal status.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.23Notificationh3cEntityExternalAlarmOccurcurrentThe trap is generated when the monitored device connected to the specified entity fails.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.24Notificationh3cEntityExternalAlarmRecovercurrentThe trap is generated when the failed device connected to the specified entity returns to normal.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.25Notificationh3cEntityExtCpuUsageThresholdRecovercurrentThe trap indicates the CPU usage descends the threshold.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.26Notificationh3cEntityExtMemUsageThresholdRecovercurrentThe trap indicates the memory usage descends the threshold.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.27Notificationh3cEntityExtMemAllocatedFailedcurrentThe trap indicates the memory allocated failed.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.28Notificationh3cEntityExtECCParityAlarmcurrentThe trap indicates the ECC(Error Correction Code) parity error alarm.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.29Notificationh3cEntityExtCritLowerTempThresholdNotificationcurrentThe h3cEntityExtCritLowerTempThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity …
1.3.6.1.4.1.43.45.1.10.2.6.2.0.30Notificationh3cEntityExtTemperatureTooLowcurrentThe h3cEntityExtTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity…
1.3.6.1.4.1.43.45.1.10.2.6.2.0.31Notificationh3cEntityExtFanDirectionNotPreferredcurrentThis trap indicates the specified fan's direction does not accord with preferred. The two parameters indicate the entity index and physical name of fan.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.32Notificationh3cEntityExtFanDirectionNotAccordcurrentThis trap indicates the direction of fans does not accord with each other. The two parameters indicate the parent entity of the fans.
1.3.6.1.4.1.43.45.1.10.2.6.2.0.33Notificationh3cEntityExtSFPInvalidcurrentThe transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transcei…
1.3.6.1.4.1.43.45.1.10.2.6.2.0.34Notificationh3cEntityExtSFPInvalidNowcurrentThis transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transce…
1.3.6.1.4.1.43.45.1.10.2.6.2.1Nodeh3cEntityExtTrapsInfor
1.3.6.1.4.1.43.45.1.10.2.6.2.1.1Scalarh3cEntityExtTrapDescriptionaccessible-for-notifycurrentThe information of trap.
1.3.6.1.4.1.43.45.1.10.2.6.2.1.2Scalarh3cEntityExtECCParityAlarmStatusaccessible-for-notifycurrentECC parity error.
1.3.6.1.4.1.43.45.1.10.2.6.2.1.3Scalarh3cEntityExtSFPInvalidInDaysaccessible-for-notifycurrentThe days when the transceiver module is still valid, but after those days, it will be invaldated.
1.3.6.1.4.1.43.45.1.10.2.6.2.1.4Scalarh3cEntityExtFirstTrapTimeaccessible-for-notifycurrentRepresents the first trap time.
1.3.6.1.4.1.43.45.1.10.2.6.3Nodeh3cEntityExtConformance
1.3.6.1.4.1.43.45.1.10.2.6.3.1Nodeh3cEntityExtCompliances
1.3.6.1.4.1.43.45.1.10.2.6.3.1.1Complianceh3cEntityExtComplianceread-onlycurrentThe compliance statement for systems supporting this MIB.
1.3.6.1.4.1.43.45.1.10.2.6.3.2Nodeh3cEntityExtGroups
1.3.6.1.4.1.43.45.1.10.2.6.3.2.1Grouph3cEntityExtGroupcurrentEntity Extend group.
1.3.6.1.4.1.43.45.1.10.2.6.3.2.2Grouph3cEntityExtNotificationGroupcurrentEntity Extend Notification group.
1.3.6.1.4.1.43.45.1.10.2.6.3.2.3Grouph3cEntityExtManuGroupcurrentStandard Device Manufacture Information group.
1.3.6.1.4.1.43.45.1.10.2.6.3.2.4Grouph3cEntityExtPowerGroupcurrentStandard Entity Power Information group.
Type Definitions
NameSyntaxStatusDescription
H3cAdminStateINTEGER { notSupported(1), locked(2), shuttingDown(3), unlocked(4) }currentThe administrative state for this object, and it is possible to set the state when needed. A value of locked means the resource is administratively prohibited from use. A value of shuttingDown means that usage is admini…
H3cAlarmStatusBITS { notSupported (0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning (6), indeterminate (7) }currentRepresents the possible values of alarm status. When no bits of this attribute are set, then none of the status conditions described below are present. When the value of under repair is set, the resource is currently be…
H3cOperStateINTEGER { notSupported (1), disabled(2), enabled(3), dangerous(4) }currentRepresents the possible values of operational states. A value of disabled means the resource is totally inoperable. A value of enabled means the resource is partially or fully operable.
H3cStandbyStatusINTEGER { notSupported (1), hotStandby(2), coldStandby(3), providingService(4) }currentRepresents the possible values of standby status. A value of hotStandby means the resource is not providing service, but is will be immediately able to take over the role of the resource to be backed-up, without the nee…