MIB Viewer

A3COM-HUAWEI-POWER-ETH-EXT-MIB

129 objects
Description.
OIDNameAccessStatusDescription
1.3.6.1.4.1.43.45.1.10.2.14Identityh3cPowerEthernetExtDescription.
1.3.6.1.4.1.43.45.1.10.2.14.1Tableh3cPsePortTablenot-accessiblecurrentThe indexing scheme is taken form that used by the IETF Power MIB. The same indexing scheme is used to give continuity in behaviour between that standard and t…
1.3.6.1.4.1.43.45.1.10.2.14.1.1Rowh3cPsePortEntrynot-accessiblecurrentThe pethPsePortGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. G…
1.3.6.1.4.1.43.45.1.10.2.14.1.1.2Columnh3cPsePortFaultDescriptionread-writecurrentThe object supports the fault category of the IETF Power MIB [1] pethPsePortDetectionStatus object. A textual description containing more information about the…
1.3.6.1.4.1.43.45.1.10.2.14.1.1.3Columnh3cPsePortPeakPowerread-writecurrentThe object specifies the peak power which has been consumed by the port. It is defined as the highest measured value of power in milliWatts that has been consu…
1.3.6.1.4.1.43.45.1.10.2.14.1.1.4Columnh3cPsePortAveragePowerread-writecurrentThe object specifies the average power which has been consumed by the port. This object is a read/write integer value with units of milliWatts. Writing a value…
1.3.6.1.4.1.43.45.1.10.2.14.1.1.5Columnh3cPsePortCurrentPowerread-onlycurrentThe object specifies the power currently being consumed by the port. It is a read only integer value with units of milliWatts.
1.3.6.1.4.1.43.45.1.10.2.14.1.1.6Columnh3cPsePortPowerLimitread-writecurrentThe object specifies the power limit set for this port. The PSE will not supply more than this level of power to the specified port. It is a read/write integer…
1.3.6.1.4.1.43.45.1.10.2.14.1.1.7Columnh3cPsePortProfileIndexread-writecurrentIndicates the power profile which is currently associated with this port. This object references the corresponding h3cPseProfileIndex object in the power profi…
1.3.6.1.4.1.43.45.1.10.2.14.2Tableh3cMainPseTablenot-accessiblecurrentDescription.
1.3.6.1.4.1.43.45.1.10.2.14.2.1Rowh3cMainPseEntrynot-accessiblecurrentThe pethMainPseGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. G…
1.3.6.1.4.1.43.45.1.10.2.14.2.1.1Columnh3cMainPsePowerLimitread-writecurrentThe object specifies the power limit set for the unit as a whole. The PoE unit will already have a nominal power defined by the IETF Power MIB [1] pethMainPseP…
1.3.6.1.4.1.43.45.1.10.2.14.2.1.2Columnh3cMainPseAveragePowerread-writecurrentThe object specifies the average power which has been consumed by the port. It is a read/write integer value with units of Watts (note - Watts is chosen instea…
1.3.6.1.4.1.43.45.1.10.2.14.2.1.3Columnh3cMainPsePeakPowerread-writecurrentThe object specifies the peak power which has been consumed for PoE. It is defined as the highest measured value of power in milliWatts that has been consumed …
1.3.6.1.4.1.43.45.1.10.2.14.2.1.4Columnh3cMainGuaranteedPowerRemainingread-onlycurrentThe object specifies the amount of power remaining in the guaranteed power pool. Each time a port is placed into guaranteed mode it reserves a set amount of po…
1.3.6.1.4.1.43.45.1.10.2.14.2.1.5Columnh3cMainPsePriorityModeread-writecurrentDescribes or controls the priority mode on slot which must be enabled firstly. When a new board is inserted, and the power is over-load, a value of disconnecti…
1.3.6.1.4.1.43.45.1.10.2.14.2.1.6Columnh3cMainPseLegacyread-writecurrentDescribes or controls the legacy mode on slot which must be enabled firstly. Legacy mode: standard or nonstandard PD detection mode.
1.3.6.1.4.1.43.45.1.10.2.14.2.1.7Columnh3cMainPsePowerPriorityread-writecurrentDescribes or controls the priority of the PSE. The priority will be used by the PSE policy to prevent from power overloading. If the priority of PSE is set to …
1.3.6.1.4.1.43.45.1.10.2.14.3Scalarh3cPseAutoDetectActiveread-writecurrentThe object specifies whether the device auto-detection feature is active. If this object is set to Active, and a known powered device is detected, then the por…
1.3.6.1.4.1.43.45.1.10.2.14.4Nodeh3cPseComformance
1.3.6.1.4.1.43.45.1.10.2.14.4.1Nodeh3cPseCompliances
1.3.6.1.4.1.43.45.1.10.2.14.4.1.1Complianceh3cPseCompliancecurrentDescription.
1.3.6.1.4.1.43.45.1.10.2.14.4.2Nodeh3cPseGroup
1.3.6.1.4.1.43.45.1.10.2.14.4.2.1Grouph3cPsePortGroupcurrentA collection of objects should be supported at the same time.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.2Grouph3cMainPseGroupcurrentA collection of objects should be supported at the same time.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.3Grouph3cPseScalarGroupcurrentA collection of scalar objects supported.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.4Grouph3cPsePDNotificationGroupcurrentPD Change Notification.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.5Grouph3cPseProfilesGroupcurrentA collection of objects should be supported at the same time.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.6Grouph3cPOEPowerThresholdLimitGroupcurrentPower threshold limits group.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.7Grouph3cPOEPowerSupInfoGroupcurrentThe basic Power information group.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.8Grouph3cPOEPowerDCOutStateGroupcurrentThe DC out power state group.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.9Grouph3cPOEPowerDCOutInfoGroupcurrentThe power AC input switch information group
1.3.6.1.4.1.43.45.1.10.2.14.4.2.10Grouph3cPOEPowerACSwitchStateModuleGroupcurrentPD Change Notification.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.11Grouph3cPOEPowerInCurStateGroupcurrentPD Change Notification.
1.3.6.1.4.1.43.45.1.10.2.14.4.2.12Grouph3cPOEPowerAlarmStateGroupcurrentPD Change Notification.
1.3.6.1.4.1.43.45.1.10.2.14.5Scalarh3cPsePowerMaxValueread-writecurrentThe object specifies the max poe power for lanswitch. The value should between the power currently and the max power.
1.3.6.1.4.1.43.45.1.10.2.14.6Nodeh3cpseportNotification
1.3.6.1.4.1.43.45.1.10.2.14.6.1Notificationh3cpsePDChangeNotificationcurrentThis notification indicates if PD has been inserted or pulled out.
1.3.6.1.4.1.43.45.1.10.2.14.6.2Notificationh3cPOEDisconnectNotificationcurrentThis notification indicates the POE power module does not disconnect.
1.3.6.1.4.1.43.45.1.10.2.14.6.3Notificationh3cPOEInputErrorNotificationcurrentThis notification indicates the POE power module input error.
1.3.6.1.4.1.43.45.1.10.2.14.6.4Notificationh3cPOEOutputErrorNotificationcurrentThis notification indicates the POE power module output error.
1.3.6.1.4.1.43.45.1.10.2.14.6.5Notificationh3cPOEOverVoltageNotificationcurrentThis notification indicates the POE power module overruns the voltage limit.
1.3.6.1.4.1.43.45.1.10.2.14.6.6Notificationh3cPOEOverTempNotificationcurrentThis notification indicates the POE power module overruns the temperature limit.
1.3.6.1.4.1.43.45.1.10.2.14.6.7Notificationh3cPOEFanErrorNotificationcurrentThis notification indicates the POE power module fan error.
1.3.6.1.4.1.43.45.1.10.2.14.6.8Notificationh3cPOEModuleShutdownNotificationcurrentThis notification indicates the POE power module is closed.
1.3.6.1.4.1.43.45.1.10.2.14.6.9Notificationh3cPOECurRestrictedNotificationcurrentThis notification indicates the POE power module current is restricted.
1.3.6.1.4.1.43.45.1.10.2.14.6.10Notificationh3cPOEACSwitchNotificationcurrentThis notification indicates the AC input switch alarm of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.11Notificationh3cPOEACInCurANotificationcurrentThis notification indicates the AC input current A alarm state of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.12Notificationh3cPOEACInCurBNotificationcurrentThis notification indicates the AC input current B alarm state of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.13Notificationh3cPOEACInCurCNotificationcurrentThis notification indicates the AC input current C alarm state of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.14Notificationh3cPOEACSwitchVolABNotificationcurrentThis notification indicates the AC input voltage AB alarm state of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.15Notificationh3cPOEACSwitchVolBCNotificationcurrentThis notification indicates the AC input voltage BC alarm state of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.16Notificationh3cPOEACSwitchVolCANotificationcurrentThis notification indicates the AC input voltage CA alarm state of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.17Notificationh3cPOEDCOutVolNotificationcurrentThis notification indicates the DC output alarm of this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.6.18Notificationh3cPOEShutdownNotificationcurrentThis notification indicates the whole POE power has been shutdown.
1.3.6.1.4.1.43.45.1.10.2.14.7Tableh3cPseProfilesTablenot-accessiblecurrentA table of objects representing a set of power profiles. Power profiles can be applied to PoE ports, which have the effect of automatically setting the priorit…
1.3.6.1.4.1.43.45.1.10.2.14.7.1Rowh3cPseProfilesEntrynot-accessiblecurrentA set of objects that display and control the Main power of a PSE.
1.3.6.1.4.1.43.45.1.10.2.14.7.1.1Columnh3cPseProfileIndexnot-accessiblecurrentThe index of the profile. This uniquely allow the profile to be identified.
1.3.6.1.4.1.43.45.1.10.2.14.7.1.2Columnh3cPseProfileNameread-createcurrentAssigns the profile a name with which the settings can be assiciated with. For example, 'NBX Phone'.
1.3.6.1.4.1.43.45.1.10.2.14.7.1.3Columnh3cPseProfilePowerModeread-createcurrentThe power mode associated with this power profile. There are two possible power modes as follows: powerDisabled, powerEnabled. When a power profile is applied …
1.3.6.1.4.1.43.45.1.10.2.14.7.1.4Columnh3cPseProfilePowerLimitread-createcurrentThe power limit to be applied to the ports h3cPsePortPowerLimit object when the profile is applied to the PSE port. Expressed in milliWatts.
1.3.6.1.4.1.43.45.1.10.2.14.7.1.5Columnh3cPseProfilePriorityread-createcurrentThis object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used b…
1.3.6.1.4.1.43.45.1.10.2.14.7.1.6Columnh3cPseProfilePairsread-createcurrentDescribes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the sign…
1.3.6.1.4.1.43.45.1.10.2.14.7.1.7Columnh3cPseProfileApplyNumread-onlycurrentThe number of this profile which has been applied. If h3cPseProfileApplyNum is not zero, user can't change the current line.
1.3.6.1.4.1.43.45.1.10.2.14.7.1.8Columnh3cPseProfileRowStatusread-createcurrentThe status of this classifier. If h3cPseProfileApplyNum is not zero, user can't delete the current line.
1.3.6.1.4.1.43.45.1.10.2.14.8Nodeh3cPOEPowerObjects
1.3.6.1.4.1.43.45.1.10.2.14.8.1Nodeh3cPOEThresholdLimitObjs
1.3.6.1.4.1.43.45.1.10.2.14.8.1.1Scalarh3cPOEThresholdACMimimumread-writecurrentInput threshold AC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit …
1.3.6.1.4.1.43.45.1.10.2.14.8.1.2Scalarh3cPOEThresholdACMaximumread-writecurrentInput threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit …
1.3.6.1.4.1.43.45.1.10.2.14.8.1.3Scalarh3cPOEThresholdDCMinimumread-writecurrentInput threshold DC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit …
1.3.6.1.4.1.43.45.1.10.2.14.8.1.4Scalarh3cPOEThresholdDCMaximumread-writecurrentInput threshold DC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit …
1.3.6.1.4.1.43.45.1.10.2.14.8.2Nodeh3cPOESupModuleInfoObjs
1.3.6.1.4.1.43.45.1.10.2.14.8.2.1Scalarh3cPOEPowerTyperead-onlycurrentThe type of the power.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.2Scalarh3cPOEPowerModuleNumread-onlycurrentThe number of the power modules.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.3Scalarh3cPOESupervisionModuleNameread-onlycurrentThe object specifies the Supervision Module name on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.4Scalarh3cPOESMMajorVersionread-onlycurrentThe object specifies the high byte of the monitor module version.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.5Scalarh3cPOESMMinorVersionread-onlycurrentThe object specifies the low byte of the monitor module version.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.6Scalarh3cPOESMFactorNameread-onlycurrentThe object specifies the name of the manufactor.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.7Tableh3cPOEModuleInfoTablenot-accessiblecurrentThe table of the module information on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.7.1Rowh3cPOEModuleInfoEntrynot-accessiblecurrentThe entry of the module information on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.7.1.1Columnh3cPOEModuleIndexaccessible-for-notifycurrentThe index of the current module on this POE power. It is also the index of h3cPOEModuleInfoTable. The range of this node is from 1 to h3cPOEPowerModuleNum.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.7.1.2Columnh3cPOEModuleIDread-onlycurrentThe ID of the current module on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.7.1.3Columnh3cPOEModuleInfoPowerread-onlycurrentThe power of the current module on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.2.7.1.4Columnh3cPOEModuleHardVerInforead-onlycurrentThe hardware version information of the current module on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.3Nodeh3cPOEDCOutStateObjects
1.3.6.1.4.1.43.45.1.10.2.14.8.3.1Scalarh3cPOEDCOutStateModuleNumread-onlycurrentThe module number on this POE power. It is the maximum of the h3cPOEDCOutStateIndex.
1.3.6.1.4.1.43.45.1.10.2.14.8.3.2Tableh3cPOEDCOutStateTablenot-accessiblecurrentThe table of DC output power state on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.3.2.1Rowh3cPOEDCOutStateEntrynot-accessiblecurrentThe entry of the DC output power state on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.3.2.1.1Columnh3cPOEDCOutStateIndexaccessible-for-notifycurrentThe index of the DC output power state on this POE power. The range of this node is from 1 to h3cPOEDCOutStateModuleNum.
1.3.6.1.4.1.43.45.1.10.2.14.8.3.2.1.2Columnh3cPOEDCOutDCVolAlarmread-onlycurrentThe DC output alarm of the DC output power state on this POE power. The value of this node will be the following values: normal (1), underLimit (2), aboveLimit…
1.3.6.1.4.1.43.45.1.10.2.14.8.4Nodeh3cPOEDCOutInfoObjects
1.3.6.1.4.1.43.45.1.10.2.14.8.4.1Scalarh3cPOEDCOutCurNumread-onlycurrentThe number of DC output current on this POE power. It is the maximum of h3cPOEDCOutInfoIndex.
1.3.6.1.4.1.43.45.1.10.2.14.8.4.2Tableh3cPOEDCOutInfoTablenot-accessiblecurrentThe table of the DC output information on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.4.2.1Rowh3cPOEDCOutInfoEntrynot-accessiblecurrentThe entry of the DC output information on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.4.2.1.1Columnh3cPOEDCOutInfoIndexaccessible-for-notifycurrentThe index of the DC output information on this POE POWER. The range of this node is from 1 to h3cPOEDCOutCurNum.
1.3.6.1.4.1.43.45.1.10.2.14.8.4.2.1.2Columnh3cPOEDCOutVolread-onlycurrentThe DC output voltage of the current DC output on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.4.2.1.3Columnh3cPOEDCOutInfoLoadCurread-onlycurrentThe total load current of the current DC output on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.5Nodeh3cPOEACSwitchStateModuleObjs
1.3.6.1.4.1.43.45.1.10.2.14.8.5.1Scalarh3cPOEACSwitchStateModuleNumread-onlycurrentThe number of the AC swtich state module on this POE power. It is the maximum of h3cPOEACSwitchStateIndex.
1.3.6.1.4.1.43.45.1.10.2.14.8.5.2Tableh3cPOEACSwitchStateTablenot-accessiblecurrentThe table of the AC switch state on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.5.2.1Rowh3cPOEACSwitchStateEntrynot-accessiblecurrentThe entry of the AC switch state on this POE power.
1.3.6.1.4.1.43.45.1.10.2.14.8.5.2.1.1Columnh3cPOEACSwitchStateIndexaccessible-for-notifycurrentThe index of the AC switch state on this POE power. The range of this node is from 1 to h3cPOEACSwitchStateModuleNum.
1.3.6.1.4.1.43.45.1.10.2.14.8.5.2.1.2Columnh3cPOEACSwitchStateread-onlycurrentThe AC switch state on this POE power. The value of this node will be one of the following values: on (1), off (2), highVoltInput (3), lowVoltInput (4)
1.3.6.1.4.1.43.45.1.10.2.14.8.6Nodeh3cPOEInCurStateObjects
1.3.6.1.4.1.43.45.1.10.2.14.8.6.1Scalarh3cPOEInCurStateModuleNumread-onlycurrentThe DC input current state of the module on this POE power. It is the maximum of the h3cPOESwitchStateVolExIndex.
1.3.6.1.4.1.43.45.1.10.2.14.8.6.2Scalarh3cPOEInCurAStateread-onlycurrentThe current A state in the DC input on this POE power. normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7…
1.3.6.1.4.1.43.45.1.10.2.14.8.6.3Scalarh3cPOEInCurBStateread-onlycurrentThe current B state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), …
1.3.6.1.4.1.43.45.1.10.2.14.8.6.4Scalarh3cPOEInCurCStateread-onlycurrentThe current C state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), …
1.3.6.1.4.1.43.45.1.10.2.14.8.6.5Tableh3cPOESwitchStateVolExTablenot-accessiblecurrentAll alarm status of the VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fus…
1.3.6.1.4.1.43.45.1.10.2.14.8.6.5.1Rowh3cPOESwitchStateVolExEntrynot-accessiblecurrentThe h3cPOESwitchStateVolExIndex will match the number of the VOL status.
1.3.6.1.4.1.43.45.1.10.2.14.8.6.5.1.1Columnh3cPOESwitchStateVolExIndexaccessible-for-notifycurrentThe object species the index of the VOL status. The range of this node is from 1 to h3cPOEInCurStateModuleNum.
1.3.6.1.4.1.43.45.1.10.2.14.8.6.5.1.2Columnh3cPOESwitchStateInVolABread-onlycurrentThe object specifies the VOL AB alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3…
1.3.6.1.4.1.43.45.1.10.2.14.8.6.5.1.3Columnh3cPOESwitchStateInVolBCread-onlycurrentThe object specifies the VOL BC alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3…
1.3.6.1.4.1.43.45.1.10.2.14.8.6.5.1.4Columnh3cPOESwitchStateInVolCAread-onlycurrentThe object specifies the VOL CA alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3…
1.3.6.1.4.1.43.45.1.10.2.14.8.7Nodeh3cPOEAlarmStateObjects
1.3.6.1.4.1.43.45.1.10.2.14.8.7.1Scalarh3cPOEAlarmStateModuleNumread-onlycurrentThe object specifies the number of the power modules in alarm state.
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2Tableh3cPOEAlarmStateInfoTablenot-accessiblecurrentAll alarm states in the POE power modules.
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1Rowh3cPOEAlarmStateInfoEntrynot-accessiblecurrentThe h3cPOEAlarmModuleInfoIndex will match the number of the power module.
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.1Columnh3cPOEAlarmModuleInfoIndexaccessible-for-notifycurrentThe index specifies the index of the H3cPOEAlarmStateInfoEntry table. The range of this node is from 1 to h3cPOEAlarmStateModuleNum.
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.2Columnh3cPOEModuleDisconnectread-onlycurrentThe node specifies the alarm state: The module does not link. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.3Columnh3cPOEModuleInputErrorread-onlycurrentThe node specifies the alarm state: Input error. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.4Columnh3cPOEModuleOutputErrorread-onlycurrentThe node specifies the alarm state: Output error. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.5Columnh3cPOEModuleOverVoltageread-onlycurrentThe node specifies the alarm state: The voltage is too high. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.6Columnh3cPOEModuleOverTempread-onlycurrentThe node specifies the alarm state: The temperature is too high. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.7Columnh3cPOEModuleFanErrorread-onlycurrentThe node specifies the alarm state: The fan error. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.8Columnh3cPOEModuleShutdownread-onlycurrentThe node specifies the alarm state: The module is shutdown. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.8.7.2.1.9Columnh3cPOEModuleCurRestrictedread-onlycurrentThe node specifies the alarm state: The module limit the current. The value of this node is one of the following values: normal (1), alarm (2).
1.3.6.1.4.1.43.45.1.10.2.14.9Scalarh3cPsePolicyModeread-writecurrentThe PSE policy only applies to the situation that when a new board (PSE) is inserted, and the power is overload. A value of priority(2) means that the power wi…
1.3.6.1.4.1.43.45.1.10.2.14.10Scalarh3cPDPolicyModeread-writecurrentThe PD policy only applies to the situation that when a new PD is inserted, and the power of PSE is overload. A value of priority(2) means that the power will …