POWER-ETHERNET-MIB
44 objects
The MIB module for managing Power Source Equipment (PSE) working according to the IEEE 802.af Powered Ethernet (DTE Power via MDI) standard. The following terms are used throughout this MIB module. For complete formal definitions, the IEEE 802.3 standards should be consulted wherever possible: Group - A recommended, but optional, entity defined by the IEEE 802.3 management standard, in order to support a modular numbering scheme. The classical example allows an implementor to represent field-replaceable units as groups of ports, with the port numbering matching the modular hardware implementation. Port - This entity identifies the port within the group for which this entry contains information. The numbering scheme for ports is implementation specific. Copyright (c) The Internet Society (2003). This version of this MIB module is part of RFC 3621; See the RFC itself for full legal notices.
Imported Objects
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.105 | IdentitypowerEthernetMIB | The MIB module for managing Power Source Equipment (PSE) working according to the IEEE 802.af Powered Ethernet (DTE Power via MDI) standard. The following term… | ||
| 1.3.6.1.2.1.105.0 | NodepethNotifications | |||
| 1.3.6.1.2.1.105.0.1 | NotificationpethPsePortOnOffNotification | current | This Notification indicates if Pse Port is delivering or not power to the PD. This Notification SHOULD be sent on every status change except in the searching m… | |
| 1.3.6.1.2.1.105.0.2 | NotificationpethMainPowerUsageOnNotification | current | This Notification indicate PSE Threshold usage indication is on, the usage power is above the threshold. At least 500 msec must elapse between notifications be… | |
| 1.3.6.1.2.1.105.0.3 | NotificationpethMainPowerUsageOffNotification | current | This Notification indicates PSE Threshold usage indication off, the usage power is below the threshold. At least 500 msec must elapse between notifications bei… | |
| 1.3.6.1.2.1.105.1 | NodepethObjects | |||
| 1.3.6.1.2.1.105.1.1 | TablepethPsePortTable | not-accessible | current | A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be impleme… |
| 1.3.6.1.2.1.105.1.1.1 | RowpethPsePortEntry | not-accessible | current | A set of objects that display and control the power characteristics of a power Ethernet PSE port. |
| 1.3.6.1.2.1.105.1.1.1.1 | ColumnpethPsePortGroupIndex | not-accessible | current | This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and … |
| 1.3.6.1.2.1.105.1.1.1.2 | ColumnpethPsePortIndex | not-accessible | current | This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected. |
| 1.3.6.1.2.1.105.1.1.1.3 | ColumnpethPsePortAdminEnable | read-write | current | true (1) An interface which can provide the PSE functions. false(2) The interface will act as it would if it had no PSE function. |
| 1.3.6.1.2.1.105.1.1.1.4 | ColumnpethPsePortPowerPairsControlAbility | read-only | current | Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate that the device has the capabi… |
| 1.3.6.1.2.1.105.1.1.1.5 | ColumnpethPsePortPowerPairs | read-write | current | Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the sign… |
| 1.3.6.1.2.1.105.1.1.1.6 | ColumnpethPsePortDetectionStatus | read-only | current | Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of de… |
| 1.3.6.1.2.1.105.1.1.1.7 | ColumnpethPsePortPowerPriority | read-write | current | This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used b… |
| 1.3.6.1.2.1.105.1.1.1.8 | ColumnpethPsePortMPSAbsentCounter | read-only | current | This counter is incremented when the PSE state diagram transitions directly from the state POWER_ON to the state IDLE due to tmpdo_timer_done being asserted. |
| 1.3.6.1.2.1.105.1.1.1.9 | ColumnpethPsePortType | read-write | current | A manager will set the value of this variable to indicate the type of powered device that is connected to the port. The default value supplied by the agent if … |
| 1.3.6.1.2.1.105.1.1.1.10 | ColumnpethPsePortPowerClassifications | read-only | current | Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN acce… |
| 1.3.6.1.2.1.105.1.1.1.11 | ColumnpethPsePortInvalidSignatureCounter | read-only | current | This counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID. |
| 1.3.6.1.2.1.105.1.1.1.12 | ColumnpethPsePortPowerDeniedCounter | read-only | current | This counter is incremented when the PSE state diagram enters the state POWER_DENIED. |
| 1.3.6.1.2.1.105.1.1.1.13 | ColumnpethPsePortOverLoadCounter | read-only | current | This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_OVER. |
| 1.3.6.1.2.1.105.1.1.1.14 | ColumnpethPsePortShortCounter | read-only | current | This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_SHORT. |
| 1.3.6.1.2.1.105.1.3 | NodepethMainPseObjects | |||
| 1.3.6.1.2.1.105.1.3.1 | TablepethMainPseTable | not-accessible | current | A table of objects that display and control attributes of the main power source in a PSE device. Ethernet switches are one example of boxes that would support … |
| 1.3.6.1.2.1.105.1.3.1.1 | RowpethMainPseEntry | not-accessible | current | A set of objects that display and control the Main power of a PSE. |
| 1.3.6.1.2.1.105.1.3.1.1.1 | ColumnpethMainPseGroupIndex | not-accessible | current | This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be … |
| 1.3.6.1.2.1.105.1.3.1.1.2 | ColumnpethMainPsePower | read-only | current | The nominal power of the PSE expressed in Watts. |
| 1.3.6.1.2.1.105.1.3.1.1.3 | ColumnpethMainPseOperStatus | read-only | current | The operational status of the main PSE. |
| 1.3.6.1.2.1.105.1.3.1.1.4 | ColumnpethMainPseConsumptionPower | read-only | current | Measured usage power expressed in Watts. |
| 1.3.6.1.2.1.105.1.3.1.1.5 | ColumnpethMainPseUsageThreshold | read-write | current | The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded. |
| 1.3.6.1.2.1.105.1.4 | NodepethNotificationControl | |||
| 1.3.6.1.2.1.105.1.4.1 | TablepethNotificationControlTable | not-accessible | current | A table of objects that display and control the Notification on a PSE device. Values of all read-write objects in this table are persistent at restart/reboot. |
| 1.3.6.1.2.1.105.1.4.1.1 | RowpethNotificationControlEntry | not-accessible | current | A set of objects that control the Notification events. |
| 1.3.6.1.2.1.105.1.4.1.1.1 | ColumnpethNotificationControlGroupIndex | not-accessible | current | This variable uniquely identifies the group. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, … |
| 1.3.6.1.2.1.105.1.4.1.1.2 | ColumnpethNotificationControlEnable | read-write | current | This object controls, on a per-group basis, whether or not notifications from the agent are enabled. The value true(1) means that notifications are enabled; th… |
| 1.3.6.1.2.1.105.2 | NodepethConformance | |||
| 1.3.6.1.2.1.105.2.1 | NodepethCompliances | |||
| 1.3.6.1.2.1.105.2.1.1 | CompliancepethCompliance | current | Describes the requirements for conformance to the Power Ethernet MIB. | |
| 1.3.6.1.2.1.105.2.2 | NodepethGroups | |||
| 1.3.6.1.2.1.105.2.2.1 | GrouppethPsePortGroup | current | PSE Port objects. | |
| 1.3.6.1.2.1.105.2.2.2 | GrouppethMainPseGroup | current | Main PSE Objects. | |
| 1.3.6.1.2.1.105.2.2.3 | GrouppethNotificationControlGroup | current | Notification Control Objects. | |
| 1.3.6.1.2.1.105.2.2.4 | GrouppethPsePortNotificationGroup | current | Pse Port Notifications. | |
| 1.3.6.1.2.1.105.2.2.5 | GrouppethMainPowerNotificationGroup | current | Main PSE Notifications. |