MIB Viewer

adtran/ADTRAN-GENVDSL2-LINE-MIB

654 objects
This MIB defines the objects for the VDSL2 MIB.
Imported Objects
ADTRAN-GENPORT-MIBadGenPortTrapIdentifier
ADTRAN-GENSLOT-MIBadGenSlotInfoIndex
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum
ADTRAN-SHARED-VDSL2-MIB MISSING-- adProducts -- adtran adGenVdsl2 adGenVdsl2ID
IF-MIBifIndex
SNMPv2-CONFOBJECT-GROUP
SNMPv2-MIBsysName
SNMPv2-SMICounter32 enterprises Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString RowStatus TEXTUAL-CONVENTION TimeStamp
OIDNameAccessStatusDescription
1.3.6.1.4.1.664Nodeadtran
1.3.6.1.4.1.664.1NodeadProducts
1.3.6.1.4.1.664.1.891NodeadTA5k24pVDSL2Combo
1.3.6.1.4.1.664.1.892NodeadTA5k32pVDSL2
1.3.6.1.4.1.664.1.893NodeadTA5k32pVDSL2Spltr
1.3.6.1.4.1.664.5.65.1.1NodeadGenVdsl2Prov
1.3.6.1.4.1.664.5.65.1.1.1TableadGenVdsl2LineConfProfileTablenot-accessiblecurrentThis table contains information on the VDSL2 line configuration. One entry in this table reflects a profile defined by a manager which can be used to configure…
1.3.6.1.4.1.664.5.65.1.1.1.1RowadGenVdsl2LineConfProfileEntrynot-accessiblecurrentEach entry consists of a list of parameters that represents the configuration of an VDSL2 modem. `Static' profiles - profiles are automaticly created or destro…
1.3.6.1.4.1.664.5.65.1.1.1.1.1ColumnadGenVdsl2LineConfProfileNamenot-accessiblecurrentThis object is used by the line configuration table in order to identify a row of this table. This value cannot be user-specified and is not dynamic. There is …
1.3.6.1.4.1.664.5.65.1.1.1.1.2ColumnadGenVdsl2ConfDsRateModeread-createcurrentDefines what form of downstream rate adaptation is configured on this modem.
1.3.6.1.4.1.664.5.65.1.1.1.1.3ColumnadGenVdsl2ConfDsTargetSnrMgnread-createcurrentConfigured Target Signal/Noise Margin. This is the noise margin the modem must achieve with the target BER (10-7) or better to successfully complete initializa…
1.3.6.1.4.1.664.5.65.1.1.1.1.4ColumnadGenVdsl2ConfDsMaxSnrMgnread-createcurrentConfigured Maximum acceptable Signal/Noise Margin. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize its operat…
1.3.6.1.4.1.664.5.65.1.1.1.1.5ColumnadGenVdsl2ConfDsMinSnrMgnread-createcurrentConfigured Minimum acceptable Signal/Noise Margin. If the noise margin falls below this level, the modem should attempt to increase its power output. If that i…
1.3.6.1.4.1.664.5.65.1.1.1.1.6ColumnadGenVdsl2ConfUsTargetSnrMgnread-createcurrentConfigured Target Signal/Noise Margin. This is the noise margin the modem must achieve with the target BER (10-7) or better to successfully complete initializa…
1.3.6.1.4.1.664.5.65.1.1.1.1.7ColumnadGenVdsl2ConfUsMaxSnrMgnread-createcurrentConfigured Maximum acceptable Signal/Noise Margin. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize its operat…
1.3.6.1.4.1.664.5.65.1.1.1.1.8ColumnadGenVdsl2ConfUsMinSnrMgnread-createcurrentConfigured Minimum acceptable Signal/Noise Margin. If the noise margin falls below this level, the modem should attempt to increase its power output. If that i…
1.3.6.1.4.1.664.5.65.1.1.1.1.9ColumnadGenVdsl2LineConfProfileRowStatusread-onlycurrentThis object is used to create a new row or modify or delete an existing row in this table. A profile activated by setting this object to `active'. When `active…
1.3.6.1.4.1.664.5.65.1.1.1.1.10ColumnadGenVdsl2ConfServiceModeread-createcurrentThe configuration parameter sets the modem service mode.
1.3.6.1.4.1.664.5.65.1.1.1.1.11ColumnadGenVdsl2ConfMultiModeDmtTseread-createcurrentMultimode DMT Transmission System Enabling (XTSE). A list of the different modulation types enabled in this profile for multimode. It is coded in a bit-map rep…
1.3.6.1.4.1.664.5.65.1.1.1.1.12ColumnadGenVdsl2ConfBandProfilesread-createcurrentBit-map of ITU-T G.993.2 implementation profiles supported by an VTU-x and can be provisioned on the VDSL2 line. Bit Assignments: Bit 00: Profile 8A Bit 01: Pr…
1.3.6.1.4.1.664.5.65.1.1.1.1.13ColumnadGenVdsl2ConfSpecificPsdSelectread-createcurrentThe VDSL2 specific PSD selections to be used in the upstream and downstream directions. The validity of these selections is dependent of the VDSL2 band profile…
1.3.6.1.4.1.664.5.65.1.1.1.1.14ColumnadGenVdsl2ConfUsPsdMaskU0Selectread-createcurrentEnable or disable of the use of the VDSL2 U0 band in the upstream direction. U0 is a relatively small frequency band of operation used by ADSL2+/ADSL2/ADSL mod…
1.3.6.1.4.1.664.5.65.1.1.1.1.15ColumnadGenVdsl2ConfUsTrellisread-createcurrentEnable or disable Upstream Trellis Encoding.
1.3.6.1.4.1.664.5.65.1.1.1.1.16ColumnadGenVdsl2ConfDsTrellisread-createcurrentEnable or disable Downstream Trellis Encoding.
1.3.6.1.4.1.664.5.65.1.1.1.1.17ColumnadGenVdsl2ConfUsPboSettingread-createcurrentDefines the Upstream Power Backoff mode setting.
1.3.6.1.4.1.664.5.65.1.1.1.1.18ColumnadGenVdsl2ConfDsPboSettingread-createcurrentDefines the Downstream Power Backoff mode setting.
1.3.6.1.4.1.664.5.65.1.1.1.1.19ColumnadGenVdsl2ConfUsVnoiseSettingread-createcurrentDefines upstream virtual noise setting.
1.3.6.1.4.1.664.5.65.1.1.1.1.20ColumnadGenVdsl2ConfDsVnoiseSettingread-createcurrentDefines downstream virtual noise setting.
1.3.6.1.4.1.664.5.65.1.1.1.1.21ColumnadGenVdsl2ConfUsBitSwapread-createcurrentDefines upstream Bit Swap to be enabled or not.
1.3.6.1.4.1.664.5.65.1.1.1.1.22ColumnadGenVdsl2ConfDsBitSwapread-createcurrentDefines downstream Bit Swap to be enabled or not.
1.3.6.1.4.1.664.5.65.1.1.1.1.23ColumnadGenVdsl2ConfHamBandNotchesread-createcurrentA bit-map of transmit power spectral density mask code, used to avoid interference with HAM (Handheld Amateur Radio) radio bands by introducing power control (…
1.3.6.1.4.1.664.5.65.1.1.1.1.24ColumnadGenVdsl2ConfUsNomAggTxPwrread-createcurrentThe maximum nominal aggregate transmit power in the upstream direction during initialization and Showtime. It ranges from 0 to 255 units of 0.1 dBm (physical v…
1.3.6.1.4.1.664.5.65.1.1.1.1.25ColumnadGenVdsl2ConfDsNomAggTxPwrread-createcurrentThe maximum nominal aggregate transmit power in the downstream direction during initialization and Showtime. It ranges from 0 to 255 units of 0.1 dBm (physical…
1.3.6.1.4.1.664.5.65.1.1.1.1.26ColumnadGenVdsl2ConfUsMaxNomTxPsdread-createcurrentThis parameter represents the maximum nominal transmit PSD in the upstream direction during initialization and showtime (in dBm/Hz). It ranges from -60 to -30 …
1.3.6.1.4.1.664.5.65.1.1.1.1.27ColumnadGenVdsl2ConfDsMaxNomTxPsdread-createcurrentThis parameter represents the maximum nominal transmit PSD in the downstream direction during initialization and showtime (in dBm/Hz). It ranges from -60 to -3…
1.3.6.1.4.1.664.5.65.1.1.1.1.28ColumnadGenVdsl2ConfUsMaxAggRxPwrread-createcurrentThe maximum upstream aggregate receive power over the relevant set of sub-carriers. The xTU-C should verify that the upstream power cutback is such that this m…
1.3.6.1.4.1.664.5.65.1.1.1.1.29ColumnadGenVdsl2ConfFramingModeread-createcurrentThis is the PMS-TC layer Framing mode setting.
1.3.6.1.4.1.664.5.65.1.1.1.1.30ColumnadGenVdsl2ConfUsLp0MaxPayloadRateread-createcurrentLatency Path 0 upstream maximum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.31ColumnadGenVdsl2ConfUsLp0MinPayloadRateread-createcurrentLatency Path 0 upstream minimum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.32ColumnadGenVdsl2ConfUsLp0MaxDelayread-createcurrentLatency Path 0 upstream maximum Interleave Delay. This parameter is the maximum one-way interleaving delay in milli-seconds introduced by the PMS-TC between th…
1.3.6.1.4.1.664.5.65.1.1.1.1.33ColumnadGenVdsl2ConfUsLp0MinProtectionread-createcurrentLatency Path 0 upstream Minimum Impulse Noise Protection. This parameter specifies the minimum impulse noise protection for the latency path in 0.5 fractions o…
1.3.6.1.4.1.664.5.65.1.1.1.1.34ColumnadGenVdsl2ConfUsLp0RaRatioread-createcurrentThis parameter (expressed in %) specifies the ratio that should be taken into account for the latency path when performing rate adaptation in the direction of …
1.3.6.1.4.1.664.5.65.1.1.1.1.35ColumnadGenVdsl2ConfUsLp0InitPolicyread-createcurrentSelects the US latency path 0 channel framing parameter policy during initialization. The options are to maximize net data rate (ndr) or impulse noise protecti…
1.3.6.1.4.1.664.5.65.1.1.1.1.36ColumnadGenVdsl2ConfDsLp0MaxPayloadRateread-createcurrentLatency Path 0 downstream maximum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.37ColumnadGenVdsl2ConfDsLp0MinPayloadRateread-createcurrentLatency Path 0 downstream minimum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.38ColumnadGenVdsl2ConfDsLp0MaxDelayread-createcurrentLatency Path 0 downstream maximum Interleave Delay. This parameter is the maximum one-way interleaving delay in milli-seconds introduced by the PMS-TC between …
1.3.6.1.4.1.664.5.65.1.1.1.1.39ColumnadGenVdsl2ConfDsLp0MinProtectionread-createcurrentLatency Path 0 downstream Minimum Impulse Noise Protection. This parameter specifies the minimum impulse noise protection for the latency path in 0.5 fractions…
1.3.6.1.4.1.664.5.65.1.1.1.1.40ColumnadGenVdsl2ConfDsLp0RaRatioread-createcurrentThis parameter (expressed in %) specifies the ratio that should be taken into account for the latency path when performing rate adaptation in the direction of …
1.3.6.1.4.1.664.5.65.1.1.1.1.41ColumnadGenVdsl2ConfDsLp0InitPolicyread-createcurrentSelects the DS latency path 0 channel framing parameter policy during initialization. The options are to maximize net data rate (ndr) or impulse noise protecti…
1.3.6.1.4.1.664.5.65.1.1.1.1.42ColumnadGenVdsl2ConfUsLp1MaxPayloadRateread-createcurrentLatency Path 1 upstream maximum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.43ColumnadGenVdsl2ConfUsLp1MinPayloadRateread-createcurrentLatency Path 1 upstream minimum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.44ColumnadGenVdsl2ConfUsLp1MaxDelayread-createcurrentLatency Path 1 upstream maximum Interleave Delay. This parameter is the maximum one-way interleaving delay in milli-seconds introduced by the PMS-TC between th…
1.3.6.1.4.1.664.5.65.1.1.1.1.45ColumnadGenVdsl2ConfUsLp1MinProtectionread-createcurrentLatency Path 1 upstream Minimum Impulse Noise Protection. This parameter specifies the minimum impulse noise protection for the latency path in 0.5 fractions o…
1.3.6.1.4.1.664.5.65.1.1.1.1.46ColumnadGenVdsl2ConfUsLp1RaRatioread-createcurrentThis parameter (expressed in %) specifies the ratio that should be taken into account for the latency path when performing rate adaptation in the direction of …
1.3.6.1.4.1.664.5.65.1.1.1.1.47ColumnadGenVdsl2ConfUsLp1InitPolicyread-createcurrentSelects the US latency path 1 channel framing parameter policy during initialization. The options are to maximize net data rate (ndr) or impulse noise protecti…
1.3.6.1.4.1.664.5.65.1.1.1.1.48ColumnadGenVdsl2ConfDsLp1MaxPayloadRateread-createcurrentLatency Path 1 downstream maximum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.49ColumnadGenVdsl2ConfDsLp1MinPayloadRateread-createcurrentLatency Path 1 downstream minimum payload data rate.
1.3.6.1.4.1.664.5.65.1.1.1.1.50ColumnadGenVdsl2ConfDsLp1MaxDelayread-createcurrentLatency Path 1 downstream maximum Interleave Delay. This parameter is the maximum one-way interleaving delay in milli-seconds introduced by the PMS-TC between …
1.3.6.1.4.1.664.5.65.1.1.1.1.51ColumnadGenVdsl2ConfDsLp1MinProtectionread-createcurrentLatency Path 1 downstream Minimum Impulse Noise Protection. This parameter specifies the minimum impulse noise protection for the latency path in 0.5 fractions…
1.3.6.1.4.1.664.5.65.1.1.1.1.52ColumnadGenVdsl2ConfDsLp1RaRatioread-createcurrentThis parameter (expressed in %) specifies the ratio that should be taken into account for the latency path when performing rate adaptation in the direction of …
1.3.6.1.4.1.664.5.65.1.1.1.1.53ColumnadGenVdsl2ConfDsLp1InitPolicyread-createcurrentSelects the DS latency path 1 channel framing parameter policy during initialization. The options are to maximize net data rate (ndr) or impulse noise protecti…
1.3.6.1.4.1.664.5.65.1.1.1.1.54ColumnadGenVdsl2ConfUsLp0Typeread-createcurrentSelects the US latency path 0 channel type options.
1.3.6.1.4.1.664.5.65.1.1.1.1.55ColumnadGenVdsl2ConfDsLp0Typeread-createcurrentSelects the DS latency path 0 channel type options.
1.3.6.1.4.1.664.5.65.1.1.1.1.56ColumnadGenVdsl2ConfUsLp1Typeread-createcurrentSelects the US latency path 1 channel type options.
1.3.6.1.4.1.664.5.65.1.1.1.1.57ColumnadGenVdsl2ConfDsLp1Typeread-createcurrentSelects the DS latency path 1 channel type options.
1.3.6.1.4.1.664.5.65.1.1.1.1.58ColumnadGenVdsl2ConfUsRateModeread-createcurrentDefines what form of upstream rate adaptation is configured on this modem.
1.3.6.1.4.1.664.5.65.1.1.1.1.59ColumnadGenVdsl2ConfUsCustomPboElecLenKLread-createcurrentUpstream power back-off electrical length (KL0).
1.3.6.1.4.1.664.5.65.1.1.1.1.60ColumnadGenVdsl2ConfUsCustomPboForceLenread-createcurrentUpstream power back-off force electrical length.
1.3.6.1.4.1.664.5.65.1.1.1.1.61ColumnadGenVdsl2ConfUsCustomPboBoostModeread-createcurrentUpstream power back-off boost mode.
1.3.6.1.4.1.664.5.65.1.1.1.1.62ColumnadGenVdsl2ConfDsCustomPboElecLenread-createcurrentDownstream G997.1 Exchange side electrical length. only multiples of .5 are valid
1.3.6.1.4.1.664.5.65.1.1.1.1.63ColumnadGenVdsl2ConfDsCustomPboCableAread-createcurrentDownstream G997.1 Exchange side cable parameter A.
1.3.6.1.4.1.664.5.65.1.1.1.1.64ColumnadGenVdsl2ConfDsCustomPboCableBread-createcurrentDownstream G997.1 Exchange side cable parameter B.
1.3.6.1.4.1.664.5.65.1.1.1.1.65ColumnadGenVdsl2ConfDsCustomPboCableCread-createcurrentDownstream G997.1 Exchange side cable parameter C.
1.3.6.1.4.1.664.5.65.1.1.1.1.66ColumnadGenVdsl2ConfDsCustomPboMinSignalread-createcurrentDownstream G997.1 Minimum Usable Signal. only multiples of .5 are valid
1.3.6.1.4.1.664.5.65.1.1.1.1.67ColumnadGenVdsl2ConfDsCustomPboMinFreqread-createcurrentDownstream G997.1 Minimum Power Backoff Frequency
1.3.6.1.4.1.664.5.65.1.1.1.1.68ColumnadGenVdsl2ConfDsCustomPboMaxFreqread-createcurrentDownstream G997.1 Maximum Power Backoff Frequency
1.3.6.1.4.1.664.5.65.1.1.1.1.69ColumnadGenVdsl2ConfAnfpCalValueread-createcurrentANFP loss calibration value
1.3.6.1.4.1.664.5.65.1.1.1.1.70ColumnadGenVdsl2ConfDsDownshiftSnrMgnread-createcurrentThreshold SNR margin to trigger a downstream downshift.
1.3.6.1.4.1.664.5.65.1.1.1.1.71ColumnadGenVdsl2ConfDsUpshiftSnrMgnread-createcurrentThreshold SNR margin to trigger a downstream upshift.
1.3.6.1.4.1.664.5.65.1.1.1.1.72ColumnadGenVdsl2ConfDsMinUpshiftTimeread-createcurrentMinimum configured time that must elapse between downstream upshifts. A value of 2 indicates a downshift cannot occur unless 2 seconds have elapsed since the p…
1.3.6.1.4.1.664.5.65.1.1.1.1.73ColumnadGenVdsl2ConfDsMinDownshiftTimeread-createcurrentMinimum configured time that must elapse between downstream downshifts. A value of 2 indicates a downshift cannot occur unless 2 seconds have elapsed since the…
1.3.6.1.4.1.664.5.65.1.1.1.1.74ColumnadGenVdsl2ConfUsDownshiftSnrMgnread-createcurrentThreshold SNR margin to trigger a upstream downshift.
1.3.6.1.4.1.664.5.65.1.1.1.1.75ColumnadGenVdsl2ConfUsUpshiftSnrMgnread-createcurrentThreshold SNR margin to trigger a upstream upshift.
1.3.6.1.4.1.664.5.65.1.1.1.1.76ColumnadGenVdsl2ConfUsMinUpshiftTimeread-createcurrentMinimum configured time that must elapse between upstream upshifts. A value of 2 indicates a downshift cannot occur unless 2 seconds have elapsed since the pre…
1.3.6.1.4.1.664.5.65.1.1.1.1.77ColumnadGenVdsl2ConfUsMinDownshiftTimeread-createcurrentMinimum configured time that must elapse between upstream downshifts. A value of 2 indicates a downshift cannot occur unless 2 seconds have elapsed since the p…
1.3.6.1.4.1.664.5.65.1.1.1.1.78ColumnadGenVdsl2ConfUsLp0RtxSettingread-createcurrentRetransmission setting
1.3.6.1.4.1.664.5.65.1.1.1.1.79ColumnadGenVdsl2ConfUsLp0CustomRtxMaxNdrread-createcurrentRetransmission maximum allowed net data rate. Valid values are in 8000 bps increments.
1.3.6.1.4.1.664.5.65.1.1.1.1.80ColumnadGenVdsl2ConfUsLp0CustomRtxMinDelayread-createcurrentRetransmission minimum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.81ColumnadGenVdsl2ConfUsLp0CustomRtxMaxDelayread-createcurrentRetransmission maximum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.82ColumnadGenVdsl2ConfUsLp0CustomRtxInpMinShineread-createcurrentRetransmission minimum impulse noise protection against SHINE when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.83ColumnadGenVdsl2ConfUsLp0CustomRtxInpMinReinread-createcurrentRetransmission minimum impulse noise protection against REIN when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.84ColumnadGenVdsl2ConfUsLp0CustomRtxIatReinread-createcurrentRetransmission inter-arrival time for REIN
1.3.6.1.4.1.664.5.65.1.1.1.1.85ColumnadGenVdsl2ConfUsLp0CustomRtxLeftrThreshread-createcurrentRetransmission parameter that specifies the fraction of the NDR used as the threshold to declare leftr defects. A minimum value of ETR/2 is required. A special…
1.3.6.1.4.1.664.5.65.1.1.1.1.86ColumnadGenVdsl2ConfDsLp0RtxSettingread-createcurrentRetransmission setting
1.3.6.1.4.1.664.5.65.1.1.1.1.87ColumnadGenVdsl2ConfDsLp0CustomRtxMaxNdrread-createcurrentRetransmission maximum allowed net data rate. Valid values are in 8000 bps increments.
1.3.6.1.4.1.664.5.65.1.1.1.1.88ColumnadGenVdsl2ConfDsLp0CustomRtxMinDelayread-createcurrentRetransmission minimum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.89ColumnadGenVdsl2ConfDsLp0CustomRtxMaxDelayread-createcurrentRetransmission maximum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.90ColumnadGenVdsl2ConfDsLp0CustomRtxInpMinShineread-createcurrentRetransmission minimum impulse noise protection against SHINE when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.91ColumnadGenVdsl2ConfDsLp0CustomRtxInpMinReinread-createcurrentRetransmission minimum impulse noise protection against REIN when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.92ColumnadGenVdsl2ConfDsLp0CustomRtxIatReinread-createcurrentRetransmission inter-arrival time for REIN
1.3.6.1.4.1.664.5.65.1.1.1.1.93ColumnadGenVdsl2ConfDsLp0CustomRtxLeftrThreshread-createcurrentRetransmission parameter that specifies the fraction of the NDR used as the threshold to declare leftr defects. A minimum value of ETR/2 is required. A special…
1.3.6.1.4.1.664.5.65.1.1.1.1.94ColumnadGenVdsl2ConfUsLp1RtxSettingread-createcurrentRetransmission setting
1.3.6.1.4.1.664.5.65.1.1.1.1.95ColumnadGenVdsl2ConfUsLp1CustomRtxMaxNdrread-createcurrentRetransmission maximum allowed net data rate. Valid values are in 8000 bps increments.
1.3.6.1.4.1.664.5.65.1.1.1.1.96ColumnadGenVdsl2ConfUsLp1CustomRtxMinDelayread-createcurrentRetransmission minimum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.97ColumnadGenVdsl2ConfUsLp1CustomRtxMaxDelayread-createcurrentRetransmission maximum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.98ColumnadGenVdsl2ConfUsLp1CustomRtxInpMinShineread-createcurrentRetransmission minimum impulse noise protection against SHINE when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.99ColumnadGenVdsl2ConfUsLp1CustomRtxInpMinReinread-createcurrentRetransmission minimum impulse noise protection against REIN when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.100ColumnadGenVdsl2ConfUsLp1CustomRtxIatReinread-createcurrentRetransmission inter-arrival time for REIN
1.3.6.1.4.1.664.5.65.1.1.1.1.101ColumnadGenVdsl2ConfUsLp1CustomRtxLeftrThreshread-createcurrentRetransmission parameter that specifies the fraction of the NDR used as the threshold to declare leftr defects. A minimum value of ETR/2 is required. A special…
1.3.6.1.4.1.664.5.65.1.1.1.1.102ColumnadGenVdsl2ConfDsLp1RtxSettingread-createcurrentRetransmission setting
1.3.6.1.4.1.664.5.65.1.1.1.1.103ColumnadGenVdsl2ConfDsLp1CustomRtxMaxNdrread-createcurrentRetransmission maximum allowed net data rate. Valid values are in 8000 bps increments.
1.3.6.1.4.1.664.5.65.1.1.1.1.104ColumnadGenVdsl2ConfDsLp1CustomRtxMinDelayread-createcurrentRetransmission minimum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.105ColumnadGenVdsl2ConfDsLp1CustomRtxMaxDelayread-createcurrentRetransmission maximum allowed delay
1.3.6.1.4.1.664.5.65.1.1.1.1.106ColumnadGenVdsl2ConfDsLp1CustomRtxInpMinShineread-createcurrentRetransmission minimum impulse noise protection against SHINE when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.107ColumnadGenVdsl2ConfDsLp1CustomRtxInpMinReinread-createcurrentRetransmission minimum impulse noise protection against REIN when subcarrier spacing is 4.3125Khz
1.3.6.1.4.1.664.5.65.1.1.1.1.108ColumnadGenVdsl2ConfDsLp1CustomRtxIatReinread-createcurrentRetransmission inter-arrival time for REIN
1.3.6.1.4.1.664.5.65.1.1.1.1.109ColumnadGenVdsl2ConfDsLp1CustomRtxLeftrThreshread-createcurrentRetransmission parameter that specifies the fraction of the NDR used as the threshold to declare leftr defects. A minimum value of ETR/2 is required. A special…
1.3.6.1.4.1.664.5.65.1.1.1.1.110ColumnadGenVdsl2ConfAmRadioFreqMask1read-createcurrentAM radio station 1 center frequency in kHz. Carrier frequencies around this center frequency will be masked off. The value 0 will disable the masking of the ca…
1.3.6.1.4.1.664.5.65.1.1.1.1.111ColumnadGenVdsl2ConfAmRadioFreqMask2read-createcurrentAM radio station 2 center frequency in kHz. Carrier frequencies around this center frequency will be masked off. The value 0 will disable the masking of the ca…
1.3.6.1.4.1.664.5.65.1.1.1.1.112ColumnadGenVdsl2ConfAmRadioFreqMask3read-createcurrentAM radio station 3 center frequency in kHz. Carrier frequencies around this center frequency will be masked off. The value 0 will disable the masking of the ca…
1.3.6.1.4.1.664.5.65.1.1.1.1.113ColumnadGenVdsl2ConfAmRadioFreqMask4read-createcurrentAM radio station 4 center frequency in kHz. Carrier frequencies around this center frequency will be masked off. The value 0 will disable the masking of the ca…
1.3.6.1.4.1.664.5.65.1.1.1.1.114ColumnadGenVdsl2ConfAmRadioFreqMask5read-createcurrentAM radio station 5 center frequency in kHz. Carrier frequencies around this center frequency will be masked off. The value 0 will disable the masking of the ca…
1.3.6.1.4.1.664.5.65.1.1.1.1.115ColumnadGenVdsl2ConfAmRadioFreqMask6read-createcurrentAM radio station 6 center frequency in kHz. Carrier frequencies around this center frequency will be masked off. The value 0 will disable the masking of the ca…
1.3.6.1.4.1.664.5.65.1.1.1.1.116ColumnadGenVdsl2ConfMemorySplitRatioread-createcurrentThis parameter defines the ratio of how the interleaver memory is allocated between the downstream and upstream directions. For example a ratio of 2:1 will ass…
1.3.6.1.4.1.664.5.65.1.1.1.1.117ColumnadGenVdsl2ConfRateAdaptConfigModeread-createcurrentThis parameter determines how the upshift and downshift margins and times are configured when the rate mode is set to adaptAtRuntime.
1.3.6.1.4.1.664.5.65.1.1.2TableadGenVdsl2LineAlarmConfProfileTablenot-accessiblecurrentThis table contains information on the VDSL2 line configuration. One entry in this table reflects a profile defined by a manager which can be used to configure…
1.3.6.1.4.1.664.5.65.1.1.2.1RowadGenVdsl2LineAlarmConfProfileEntrynot-accessiblecurrentEach entry consists of a list of parameters that represents the configuration of an VDSL2 modem. `Static' profiles - profiles are automaticly created or destro…
1.3.6.1.4.1.664.5.65.1.1.2.1.1ColumnadGenVdsl2LineAlarmConfProfileNamenot-accessiblecurrentThis object is used by the line configuration table in order to identify a row of this table. This value cannot be user-specified and is not dynamic. There is …
1.3.6.1.4.1.664.5.65.1.1.2.1.2ColumnadGenVdsl2VtucThreshSnrMgnread-createcurrentThe SNR margin on the VDSL2 interface below which the SNMP agent sends an adGenVdsl2USPerfSNRThresTrap. One trap will be sent per interval per interface. A val…
1.3.6.1.4.1.664.5.65.1.1.2.1.3ColumnadGenVdsl2VtucThresh15MinLofsread-createcurrentThe number of Loss of Frame Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP age…
1.3.6.1.4.1.664.5.65.1.1.2.1.4ColumnadGenVdsl2VtucThresh15MinLossread-createcurrentThe number of Loss of Signal Seconds encountered by VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent…
1.3.6.1.4.1.664.5.65.1.1.2.1.5ColumnadGenVdsl2VtucThresh15MinLolsread-createcurrentThe number of Loss of Link Seconds encountered by VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent t…
1.3.6.1.4.1.664.5.65.1.1.2.1.6ColumnadGenVdsl2VtucThresh15MinLprsread-createcurrentThe number of Loss of Power Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP age…
1.3.6.1.4.1.664.5.65.1.1.2.1.7ColumnadGenVdsl2VtucThresh15MinEsread-createcurrentThe number of Errored Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent to …
1.3.6.1.4.1.664.5.65.1.1.2.1.8ColumnadGenVdsl2VtucThresh15MinSesread-createcurrentThe number of Errored Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent to …
1.3.6.1.4.1.664.5.65.1.1.2.1.9ColumnadGenVdsl2VtucThresh15MinUasread-createcurrentThe number of Errored Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent to …
1.3.6.1.4.1.664.5.65.1.1.2.1.10ColumnadGenVdsl2VturThreshSnrMgnread-createcurrentThe SNR Margin on the VDSL2 interface below which the SNMP agent sends an adGenVdsl2DSPerfSNRThresTrap. One trap will be sent per interval per interface. A val…
1.3.6.1.4.1.664.5.65.1.1.2.1.11ColumnadGenVdsl2VturThresh15MinLofsread-createcurrentThe number of Loss of Frame Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP age…
1.3.6.1.4.1.664.5.65.1.1.2.1.12ColumnadGenVdsl2VturThresh15MinLossread-createcurrentThe number of Loss of Signal Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP ag…
1.3.6.1.4.1.664.5.65.1.1.2.1.13ColumnadGenVdsl2VturThresh15MinLprsread-createcurrentThe number of Loss of Power Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP age…
1.3.6.1.4.1.664.5.65.1.1.2.1.14ColumnadGenVdsl2VturThresh15MinEsread-createcurrentThe number of Errored Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent to …
1.3.6.1.4.1.664.5.65.1.1.2.1.15ColumnadGenVdsl2VturThresh15MinSesread-createcurrentThe number of Errored Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent to …
1.3.6.1.4.1.664.5.65.1.1.2.1.16ColumnadGenVdsl2VturThresh15MinUasread-createcurrentThe number of Errored Seconds encountered by an VDSL2 interface within any given 15 minutes performance data collection period, which causes the SNMP agent to …
1.3.6.1.4.1.664.5.65.1.1.2.1.17ColumnadGenVdsl2LineAlarmConfProfileRowStatusread-createcurrentThis object is used to create a new row or modify or delete an existing row in this table. A profile activated by setting this object to `active'. When `active…
1.3.6.1.4.1.664.5.65.1.1.2.1.18ColumnadGenVdsl2ThreshUsLp0RateUpread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate >= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.2.1.19ColumnadGenVdsl2ThreshUsLp0RateDownread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate <= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.2.1.20ColumnadGenVdsl2ThreshDsLp0RateUpread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate >= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.2.1.21ColumnadGenVdsl2ThreshDsLp0RateDownread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate <= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.2.1.22ColumnadGenVdsl2ThreshUsLp1RateUpread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate >= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.2.1.23ColumnadGenVdsl2ThreshUsLp1RateDownread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate <= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.2.1.24ColumnadGenVdsl2ThreshDsLp1RateUpread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate >= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.2.1.25ColumnadGenVdsl2ThreshDsLp1RateDownread-createcurrentConfigured change in rate on the latency path causing an adGenVdsl2VtucRateChangeTrap. A trap is produced when: ChanCurrTxRate <= ChanPrevTxRate plus the value…
1.3.6.1.4.1.664.5.65.1.1.3TableadGenVdsl2RestoreDefaultTablenot-accessiblecurrentThis table contains items to restore line and/or alarm provisioning to their default values.
1.3.6.1.4.1.664.5.65.1.1.3.1RowadGenVdsl2RestoreDefaultEntrynot-accessiblecurrentFor later
1.3.6.1.4.1.664.5.65.1.1.3.1.1ColumnadGenVdsl2ConfRestoreDefaultsread-writecurrentThis object is used to restore the set of provisioning indicated. A read will always return a value of 1.
1.3.6.1.4.1.664.5.65.1.1.4TableadGenVdsl2BandConfProfileTablenot-accessiblecurrentThis table contains information on the VDSL2 Band configuration. One entry in this table reflects band profile defined by a manager which can be used to config…
1.3.6.1.4.1.664.5.65.1.1.4.1RowadGenVdsl2BandConfProfileEntrynot-accessiblecurrentEach entry consists of a list of parameters that represents the configuration of an VDSL2 modem band parameters. These entries extend that of the adGenVdsl2Lin…
1.3.6.1.4.1.664.5.65.1.1.4.1.1ColumnadGenVdsl2BandNumberread-onlycurrentVDSL2 band number. Band values are 1 - 5 corresponding to upstream bands U0..U4 and downstream bands D1..D5.
1.3.6.1.4.1.664.5.65.1.1.4.1.2ColumnadGenVdsl2BandConfUsCustomPboCableAread-createcurrentUpstream power back-off band cable A parameter. This parameter defines the UPBO reference PSD used to compute the upstream power backoff for each upstream band…
1.3.6.1.4.1.664.5.65.1.1.4.1.3ColumnadGenVdsl2BandConfUsCustomPboCableBread-createcurrentUpstream power back-off band cable B parameter. This parameter defines the UPBO reference PSD used to compute the upstream power backoff for each upstream band…
1.3.6.1.4.1.664.5.65.1.1.5TableadGenVdsl2AlarmSlotProvTablenot-accessiblecurrentThis table sets alarm severity for all VDSL2 interfaces.
1.3.6.1.4.1.664.5.65.1.1.5.1RowadGenVdsl2AlarmSlotProvEntrynot-accessiblecurrent
1.3.6.1.4.1.664.5.65.1.1.5.1.1ColumnadGenVdsl2AlmSlotLinkdownSeverityread-writecurrentSets the Linkdown alarm severity (affects all VDSL2 Ports)
1.3.6.1.4.1.664.5.65.1.2NodeadGenVdsl2Status
1.3.6.1.4.1.664.5.65.1.2.1TableadGenVdsl2LineTablenot-accessiblecurrentThis table includes common attributes describing both ends of the line. It is required for all VDSL2 physical interfaces. VDSL2 physical interfaces are those i…
1.3.6.1.4.1.664.5.65.1.2.1.1RowadGenVdsl2LineEntrynot-accessiblecurrentAn entry in adGenVdsl2LineTable.
1.3.6.1.4.1.664.5.65.1.2.1.1.1ColumnadGenVdsl2LineCodingread-onlycurrentSpecifies the VDSL2 coding type used on this line.
1.3.6.1.4.1.664.5.65.1.2.1.1.3ColumnadGenVdsl2LinePortServiceStateread-writecurrentVDSL2 port service state.
1.3.6.1.4.1.664.5.65.1.2.1.1.6ColumnadGenVdsl2LineStatusread-onlycurrentIndicates current state of the dsl line.
1.3.6.1.4.1.664.5.65.1.2.1.1.7ColumnadGenVdsl2LineUpTimeread-onlycurrentIndicates the amount of time the line has been in showtime.
1.3.6.1.4.1.664.5.65.1.2.1.1.8ColumnadGenVdsl2LineCurrTransSysModeread-onlycurrentA report of the current operating xDSL line transmission mode. offline (0) multiMode (1) t1413 (2), g9921a (3), g9921b (4), g9921c (5), g9921h (6), g9921i (7),…
1.3.6.1.4.1.664.5.65.1.2.1.1.9ColumnadGenVdsl2LineCurrBandProfileread-onlycurrentThe current VDSL2 band profile in use.
1.3.6.1.4.1.664.5.65.1.2.1.1.10ColumnadGenVdsl2LineCurrEstimatedLengthread-onlycurrent
1.3.6.1.4.1.664.5.65.1.2.1.1.11ColumnadGenVdsl2LineCurrTpsTcFramingModeread-onlycurrentParameter that indicates the application-specific Transport Protocol Specific Transmission Convergence (TPS-TC) type.
1.3.6.1.4.1.664.5.65.1.2.2TableadGenVdsl2VtucPhysTablenot-accessiblecurrentThis table provides one row for each Vtuc. Each row contains the Physical Layer Parameters table for that Vtuc. VDSL2 physical interfaces are those ifEntries w…
1.3.6.1.4.1.664.5.65.1.2.2.1RowadGenVdsl2VtucPhysEntrynot-accessiblecurrentAn entry in the adGenVdsl2VtucPhysTable.
1.3.6.1.4.1.664.5.65.1.2.2.1.1ColumnadGenVdsl2VtucInvSerialNumberread-onlycurrentThe vendor specific string that identifies the vendor equipment.
1.3.6.1.4.1.664.5.65.1.2.2.1.2ColumnadGenVdsl2VtucInvVendorIDread-onlycurrentThe vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters.
1.3.6.1.4.1.664.5.65.1.2.2.1.3ColumnadGenVdsl2VtucInvVersionNumberread-onlycurrentThe vendor specific version number sent by this ATU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[…
1.3.6.1.4.1.664.5.65.1.2.2.1.4ColumnadGenVdsl2CurrUSSnrMgnread-onlycurrentNoise Margin as seen by this ATU with respect to its received signal in tenth dB.
1.3.6.1.4.1.664.5.65.1.2.2.1.5ColumnadGenVdsl2CurrUSAtnread-onlycurrentMeasured difference in the total power transmitted by the peer ATU and the total power received by this ATU.
1.3.6.1.4.1.664.5.65.1.2.2.1.6ColumnadGenVdsl2VtucCurrStatusread-onlycurrentIndicates current state of the Vtuc line. This is a bit-map of possible conditions. The various bit positions are: Bit 00 : There no defects on the line Bit 01…
1.3.6.1.4.1.664.5.65.1.2.2.1.7ColumnadGenVdsl2VtucCurrOutputPwrread-onlycurrentMeasured total output power transmitted by this ATU. This is the measurement that was reported during the last activation sequence.
1.3.6.1.4.1.664.5.65.1.2.2.1.8ColumnadGenVdsl2VtucCurrAttainableRateread-onlycurrentIndicates the maximum currently attainable data rate by the ATU. This value will be equal or greater than the current line rate.
1.3.6.1.4.1.664.5.65.1.2.2.1.9ColumnadGenVdsl2VtucCurrTxRateread-onlycurrentThe payload rate of the last successful train.
1.3.6.1.4.1.664.5.65.1.2.2.1.10ColumnadGenVdsl2VtucPrevTxRateread-onlycurrentThe payload rate of the previous successful train.
1.3.6.1.4.1.664.5.65.1.2.2.1.11ColumnadGenVdsl2VtucActTxPsdread-onlycurrentActual Power Spectrum Density (PSD) transmitted. The average transmit PSD over the sub-carriers. It ranges from -900 to 0 units of 0.1 dB (Physical values are …
1.3.6.1.4.1.664.5.65.1.2.2.1.12ColumnadGenVdsl2VtucCurrTpsTcStatusread-onlycurrentAttributes with this syntax are status parameters that reflect the failure status for Transmission Convergence (TC) layer of a given data layer interface (data…
1.3.6.1.4.1.664.5.65.1.2.2.1.13ColumnadGenVdsl2VtucCurrTxLineRateread-onlycurrentThe line rate, including all payload and overhead rates.
1.3.6.1.4.1.664.5.65.1.2.2.1.14ColumnadGenVdsl2VtucPrevTxLineRateread-onlycurrentThe line rate, including all payload and overhead rates, of the previous successful train.
1.3.6.1.4.1.664.5.65.1.2.2.1.15ColumnadGenVdsl2VtucCircuitProviderCoderead-onlycurrentReturns local circuit provider code
1.3.6.1.4.1.664.5.65.1.2.2.1.16ColumnadGenVdsl2VtucCurrTxRateMaxread-onlycurrentReturns max payload rate since last successful train.
1.3.6.1.4.1.664.5.65.1.2.2.1.17ColumnadGenVdsl2VtucCurrTxRateMinread-onlycurrentReturns min payload rate since last successful train.
1.3.6.1.4.1.664.5.65.1.2.2.1.18ColumnadGenVdsl2VtucLastSraDownshiftread-onlycurrentReturns system uptime of last SRA downshift since last successful train.
1.3.6.1.4.1.664.5.65.1.2.2.1.19ColumnadGenVdsl2VtucLastSraUpshiftread-onlycurrentReturns system uptime of last SRA upshift since last successful train.
1.3.6.1.4.1.664.5.65.1.2.2.1.20ColumnadGenVdsl2VtucRtxUsedread-onlycurrentSpecifies whether retransmission is active in the transmit direction.
1.3.6.1.4.1.664.5.65.1.2.2.1.21ColumnadGenVdsl2VtucRtxEtrread-onlycurrentExpected throughput rate calculated from combined effect of impulse noise protection against worst-case REIN and worst-case SHINE and overhead from correction …
1.3.6.1.4.1.664.5.65.1.2.3TableadGenVdsl2VturPhysTablenot-accessiblecurrentThis table provides one row for each Vtur. Each row contains the Physical Layer Parameters table for that Vtur. VDSL2 physical interfaces are those ifEntries w…
1.3.6.1.4.1.664.5.65.1.2.3.1RowadGenVdsl2VturPhysEntrynot-accessiblecurrentAn entry in the adGenVdsl2VturPhysTable.
1.3.6.1.4.1.664.5.65.1.2.3.1.1ColumnadGenVdsl2VturInvSerialNumberread-onlycurrentThe vendor specific string that identifies the vendor equipment.
1.3.6.1.4.1.664.5.65.1.2.3.1.2ColumnadGenVdsl2VturInvVendorIDread-onlycurrentThe vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters.
1.3.6.1.4.1.664.5.65.1.2.3.1.3ColumnadGenVdsl2VturInvVersionNumberread-onlycurrentThe vendor specific version number sent by this ATU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[…
1.3.6.1.4.1.664.5.65.1.2.3.1.4ColumnadGenVdsl2CurrDSSnrMgnread-onlycurrentNoise Margin as seen by this ATU with respect to its received signal in tenth dB.
1.3.6.1.4.1.664.5.65.1.2.3.1.5ColumnadGenVdsl2CurrDSAtnread-onlycurrentMeasured difference in the total power transmitted by the peer ATU and the total power received by this ATU.
1.3.6.1.4.1.664.5.65.1.2.3.1.6ColumnadGenVdsl2VturCurrStatusread-onlycurrentIndicates current state of the Vtur line. This is a bit-map of possible conditions. Due to the isolation of the Vtur when line problems occur, many state condi…
1.3.6.1.4.1.664.5.65.1.2.3.1.7ColumnadGenVdsl2VturCurrOutputPwrread-onlycurrentMeasured total output power transmitted by this ATU. This is the measurement that was reported during the last activation sequence.
1.3.6.1.4.1.664.5.65.1.2.3.1.8ColumnadGenVdsl2VturCurrAttainableRateread-onlycurrentIndicates the maximum currently attainable data rate by the ATU. This value will be equal or greater than the current line rate.
1.3.6.1.4.1.664.5.65.1.2.3.1.9ColumnadGenVdsl2VturCurrTxRateread-onlycurrentThe payload rate of the last successful train.
1.3.6.1.4.1.664.5.65.1.2.3.1.10ColumnadGenVdsl2VturPrevTxRateread-onlycurrentThe payload rate of the previous successful train.
1.3.6.1.4.1.664.5.65.1.2.3.1.11ColumnadGenVdsl2VturActTxPsdread-onlycurrentActual Power Spectrum Density (PSD) transmitted. The average transmit PSD over the sub-carriers. It ranges from -900 to 0 units of 0.1 dB (Physical values are …
1.3.6.1.4.1.664.5.65.1.2.3.1.12ColumnadGenVdsl2VturCurrTxLineRateread-onlycurrentThe line rate, including all payload and overhead rates.
1.3.6.1.4.1.664.5.65.1.2.3.1.13ColumnadGenVdsl2VturPrevTxLineRateread-onlycurrentThe line rate, including all payload and overhead rates, of the previous successful train.
1.3.6.1.4.1.664.5.65.1.2.3.1.14ColumnadGenVdsl2VturCircuitProviderCoderead-onlycurrentReturns remote circuit provider code
1.3.6.1.4.1.664.5.65.1.2.3.1.15ColumnadGenVdsl2VturCircuitCapabilitiesread-onlycurrentReturns remote circuit capabilities in bit masks with following order: 0 - Disabled, 1 - Enabled Byte Order of octet string: Byte 0. Byte 1. Byte 2. Byte 3. By…
1.3.6.1.4.1.664.5.65.1.2.3.1.16ColumnadGenVdsl2VturCurrTxRateMaxread-onlycurrentReturns max payload rate since last successful train.
1.3.6.1.4.1.664.5.65.1.2.3.1.17ColumnadGenVdsl2VturCurrTxRateMinread-onlycurrentReturns min payload rate since last successful train.
1.3.6.1.4.1.664.5.65.1.2.3.1.18ColumnadGenVdsl2VturLastSraDownshiftread-onlycurrentReturns system uptime of last SRA downshift since last successful train.
1.3.6.1.4.1.664.5.65.1.2.3.1.19ColumnadGenVdsl2VturLastSraUpshiftread-onlycurrentReturns system uptime of last SRA upshift since last successful train.
1.3.6.1.4.1.664.5.65.1.2.3.1.20ColumnadGenVdsl2VturRtxUsedread-onlycurrentSpecifies whether retransmission is active in the transmit direction.
1.3.6.1.4.1.664.5.65.1.2.3.1.21ColumnadGenVdsl2VturRtxEtrread-onlycurrentExpected throughput rate calculated from combined effect of impulse noise protection against worst-case REIN and worst-case SHINE and overhead from correction …
1.3.6.1.4.1.664.5.65.1.2.4TableadGenVdsl2VtucChanTablenot-accessiblecurrentThis table provides one row for each Vtuc channel. VDSL2 channel interfaces are those ifEntries where ifType is equal to channel.
1.3.6.1.4.1.664.5.65.1.2.4.1RowadGenVdsl2VtucChanEntrynot-accessiblecurrentAn entry in the adGenVdsl2VtucChanTable.
1.3.6.1.4.1.664.5.65.1.2.4.1.1ColumnadGenVdsl2VtucChannelNumberread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.2.4.1.2ColumnadGenVdsl2VtucChanInterleaveDelayread-onlycurrentInterleave Delay for this channel. Interleave delay applies only to the interleave channel and defines the mapping (relative spacing) between subsequent input …
1.3.6.1.4.1.664.5.65.1.2.4.1.3ColumnadGenVdsl2VtucChanCurrTxRateread-onlycurrentActual transmit rate on this channel.
1.3.6.1.4.1.664.5.65.1.2.4.1.4ColumnadGenVdsl2VtucChanPrevTxRateread-onlycurrentThe rate at the time of the last adGenVdsl2VtucRateChangeTrap event. It is also set at initialization to prevent a trap being sent. Rate changes less than adGe…
1.3.6.1.4.1.664.5.65.1.2.4.1.5ColumnadGenVdsl2VtucChanCrcBlockLengthread-onlycurrentIndicates the length of the channel data-block on which the CRC operates. Refer to Line Code Specific MIBs, [11] and [12] for more information.
1.3.6.1.4.1.664.5.65.1.2.4.1.6ColumnadGenVdsl2VtucChanINPread-onlycurrentCurrent impulse noise protection on this channel, measured in increments of 0.1 DMT symbols.
1.3.6.1.4.1.664.5.65.1.2.4.1.7ColumnadGenVdsl2VtucChanINPReinread-onlycurrentCurrent impulse noise protection against REIN on this channel, measured in increments of 0.1 DMT symbols.
1.3.6.1.4.1.664.5.65.1.2.5TableadGenVdsl2VturChanTablenot-accessiblecurrentThis table provides one row for each Vtur channel. VDSL2 channel interfaces are those ifEntries where ifType is equal to channel.
1.3.6.1.4.1.664.5.65.1.2.5.1RowadGenVdsl2VturChanEntrynot-accessiblecurrentAn entry in the adGenVdsl2VturChanTable.
1.3.6.1.4.1.664.5.65.1.2.5.1.1ColumnadGenVdsl2VturChannelNumberread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.2.5.1.2ColumnadGenVdsl2VturChanInterleaveDelayread-onlycurrentInterleave Delay for this channel. Interleave delay applies only to the interleave channel and defines the mapping (relative spacing) between subsequent input …
1.3.6.1.4.1.664.5.65.1.2.5.1.3ColumnadGenVdsl2VturChanCurrTxRateread-onlycurrentActual transmit rate on this channel.
1.3.6.1.4.1.664.5.65.1.2.5.1.4ColumnadGenVdsl2VturChanPrevTxRateread-onlycurrentThe rate at the time of the last adGenVdsl2VturRateChangeTrap event. It is also set at initialization to prevent a trap being sent. Rate changes less than adGe…
1.3.6.1.4.1.664.5.65.1.2.5.1.5ColumnadGenVdsl2VturChanCrcBlockLengthread-onlycurrentIndicates the length of the channel data-block on which the CRC operates. Refer to Line Code Specific MIBs, [11] and [12] for more information.
1.3.6.1.4.1.664.5.65.1.2.5.1.6ColumnadGenVdsl2VturChanINPread-onlycurrentCurrent impulse noise protection on this channel, measured in increments of 0.1 DMT symbols.
1.3.6.1.4.1.664.5.65.1.2.5.1.7ColumnadGenVdsl2VturChanINPReinread-onlycurrentCurrent impulse noise protection against REIN on this channel, measured in increments of 0.1 DMT symbols.
1.3.6.1.4.1.664.5.65.1.2.6TableadGenVdsl2BandStatusTablenot-accessiblecurrentThis table contains per band status information for VDSL2 configuration. One entry in this table reflects band profile defined by a manager which can be used t…
1.3.6.1.4.1.664.5.65.1.2.6.1RowadGenVdsl2BandStatusEntrynot-accessiblecurrentEach entry consists of a list of band status items.
1.3.6.1.4.1.664.5.65.1.2.6.1.1ColumnadGenVdsl2BandStatusNumberread-onlycurrentVDSL2 band number. Band values are 1 - 5 corresponding to upstream bands U0..U4 and downstream bands D1..D5.
1.3.6.1.4.1.664.5.65.1.2.6.1.2ColumnadGenVdsl2BandStatusUsStartCarrierread-onlycurrentThe starting carrier of the VDSL2 upstream band at 4.3125KHz spacing
1.3.6.1.4.1.664.5.65.1.2.6.1.3ColumnadGenVdsl2BandStatusUsStopCarrierread-onlycurrentThe ending carrier of the VDSL2 upstream band at 4.3125KHz spacing
1.3.6.1.4.1.664.5.65.1.2.6.1.4ColumnadGenVdsl2BandStatusUsMarginread-onlycurrentUpstream Signal-to-Noise Ratio Margin per Band. This parameter is defined by usable band. The upstream signal to noise ratio margin per band is the maximum inc…
1.3.6.1.4.1.664.5.65.1.2.6.1.5ColumnadGenVdsl2BandStatusUsLatnread-onlycurrentUpstream Line Attenuation per Band. This parameter is defined per usable bands. It is the measured difference in the total power transmitted in this band and t…
1.3.6.1.4.1.664.5.65.1.2.6.1.6ColumnadGenVdsl2BandStatusUsSatnread-onlycurrentUpstream Signal Attenuation per Band. This parameter is defined per usable bands. It is the measured difference in the total power transmitted in this band and…
1.3.6.1.4.1.664.5.65.1.2.6.1.7ColumnadGenVdsl2BandStatusDsStartCarrierread-onlycurrentThe starting carrier of the VDSL2 downstream band at 4.3125KHz spacing
1.3.6.1.4.1.664.5.65.1.2.6.1.8ColumnadGenVdsl2BandStatusDsStopCarrierread-onlycurrentThe ending carrier of the VDSL2 downstream band at 4.3125KHz spacing
1.3.6.1.4.1.664.5.65.1.2.6.1.9ColumnadGenVdsl2BandStatusDsMarginread-onlycurrentDownstream Signal-to-Noise Ratio Margin per Band. This parameter is defined by usable band. The downstream signal to noise ratio margin per band is the maximum…
1.3.6.1.4.1.664.5.65.1.2.6.1.10ColumnadGenVdsl2BandStatusDsLatnread-onlycurrentDownstream Line Attenuation per Band. This parameter is defined per usable bands. It is the measured difference in the total power transmitted in this band and…
1.3.6.1.4.1.664.5.65.1.2.6.1.11ColumnadGenVdsl2BandStatusDsSatnread-onlycurrentDownstream Signal Attenuation per Band. This parameter is defined per usable bands. It is the measured difference in the total power transmitted in this band a…
1.3.6.1.4.1.664.5.65.1.2.7TableadGenVdsl2ScStatusTablenot-accessiblecurrentThis table contains per band status information for VDSL2 configuration. One entry in this table reflects band profile defined by a manager which can be used t…
1.3.6.1.4.1.664.5.65.1.2.7.1RowadGenVdsl2ScStatusEntrynot-accessiblecurrentEach entry consists of a list of band status items.
1.3.6.1.4.1.664.5.65.1.2.7.1.1ColumnadGenVdsl2ScStatusNumberread-onlycurrentDMT subcarrier number. There are 4096 possible DMT sub-carriers spaced by 4.3125 KHz in the upstream and downstream directions. These carriers are typically br…
1.3.6.1.4.1.664.5.65.1.2.7.1.2ColumnadGenVdsl2ScStatusUsBitsread-onlycurrentBits allocated per subcarrier in the upstream direction. Value ranges from 0 to 15. A zero value indicates that no bits are allocated the upstream subcarrier.
1.3.6.1.4.1.664.5.65.1.2.7.1.3ColumnadGenVdsl2ScStatusUsGainread-onlycurrentUpstream gains allocation per subcarrier. It is an array of integer values in the range of 0 to 4095 for each subcarrier. The gain value is represented as a mu…
1.3.6.1.4.1.664.5.65.1.2.7.1.4ColumnadGenVdsl2ScStatusUsSnrread-onlycurrentUpstream signal to noise (SNR) per sub-carrier number. The SNR ranges from 0 to +95.0 dB with 0.1 dB steps. A special value of 955 indicates that no measuremen…
1.3.6.1.4.1.664.5.65.1.2.7.1.5ColumnadGenVdsl2ScStatusDsBitsread-onlycurrentBits allocated per subcarrier in the downstream direction. Value ranges from 0 to 15. A zero value indicates that no bits are allocated the downstream subcarri…
1.3.6.1.4.1.664.5.65.1.2.7.1.6ColumnadGenVdsl2ScStatusDsGainread-onlycurrentDownstream gains allocation per subcarrier. It is an array of integer values in the range of 0 to 4095 for each subcarrier. The gain value is represented as a …
1.3.6.1.4.1.664.5.65.1.2.7.1.7ColumnadGenVdsl2ScStatusDsSnrread-onlycurrentDownstream signal to noise (SNR) per sub-carrier number. The SNR ranges from 0 to +95.0 dB with 0.1 dB steps. A special value of 955 indicates that no measurem…
1.3.6.1.4.1.664.5.65.1.2.7.1.8ColumnadGenVdsl2ScStatusUsQlnread-onlycurrentUpstream quiet line noise (QLN) per sub-carrier number. The QLN ranges from -150.5 to -23.0 dBm/Hz with 0.1 dB steps. A special value of -1505 indicates that n…
1.3.6.1.4.1.664.5.65.1.2.7.1.9ColumnadGenVdsl2ScStatusDsQlnread-onlycurrentUpstream quiet line noise (QLN) per sub-carrier number. The QLN ranges from -150.5 to -23.0 dBm/Hz with 0.1 dB steps. A special value of -1505 indicates that n…
1.3.6.1.4.1.664.5.65.1.2.7.1.10ColumnadGenVdsl2ScStatusUsHlogread-onlycurrentUpstream channel transfer function (HLOG) per sub-carrier number. The HLOG ranges from -96.3 to +6.0 dB with 0.1 dB steps. A special value of -963 indicates th…
1.3.6.1.4.1.664.5.65.1.2.7.1.11ColumnadGenVdsl2ScStatusDsHlogread-onlycurrentDownstream channel transfer function (HLOG) per sub-carrier number. The HLOG ranges from -96.3 to +6.0 dB with 0.1 dB steps. A special value of -963 indicates …
1.3.6.1.4.1.664.5.65.1.2.8TableadGenVdsl2ReserveInstanceBulkVDSLTlvTablenot-accessiblecurrentTable contains instances that are created when there is a request to reserve a Bulk VDSL instance
1.3.6.1.4.1.664.5.65.1.2.8.1RowadGenVdsl2ReserveInstanceBulkVDSLTlvEntrynot-accessiblecurrentIndex is the slot number.
1.3.6.1.4.1.664.5.65.1.2.8.1.1ColumnadGenVdsl2ReserveInstanceBulkVDSLSlotInstanceread-onlycurrentUsed to index the Tlv table; each time this is called by slot it creates an instance for that viewer
1.3.6.1.4.1.664.5.65.1.2.9TableadGenVdsl2BulkVDSLTlvTablenot-accessiblecurrentTable contains filters that can be applied on the requested instances
1.3.6.1.4.1.664.5.65.1.2.9.1RowadGenVdsl2BulkVDSLTlvEntrynot-accessiblecurrentIndexes are the slot and instance number
1.3.6.1.4.1.664.5.65.1.2.9.1.1ColumnadGenVdsl2BulkVDSLTlvInstancenot-accessiblecurrentUsed to index the table by TLV Instance number.
1.3.6.1.4.1.664.5.65.1.2.9.1.2ColumnadGenVdsl2BulkVDSLTlvTyperead-writecurrentUsed to set the type of VDSL info to return in the VDSL TLV instance: 1 - Bit Allocation Table (BAT), 2 - Signal Noise Ratio (SNR), 3 - Quiet Line Noise (QLN),…
1.3.6.1.4.1.664.5.65.1.2.9.1.3ColumnadGenVdsl2BulkVDSLTlvPortread-writecurrentUsed to set the VDSL port to get the info for VDSL TLV instance
1.3.6.1.4.1.664.5.65.1.2.9.1.4ColumnadGenVdsl2BulkVDLSTlvCreateread-writecurrentSet this OID to 1 to update the instance with Bulk VDSL info depending on type set. A get on this OID always returns a 1.
1.3.6.1.4.1.664.5.65.1.3NodeadGenVdsl2PM
1.3.6.1.4.1.664.5.65.1.3.1TableadGenVdsl2VtucPerfDataTablenot-accessiblecurrentThis table provides one row for each Vtuc. VDSL2 physical interfaces are those ifEntries where ifType is equal to vdsl(97).
1.3.6.1.4.1.664.5.65.1.3.1.1RowadGenVdsl2VtucPerfDataEntrynot-accessiblecurrentAn entry in adGenVdsl2VtucPerfDataTable.
1.3.6.1.4.1.664.5.65.1.3.1.1.1ColumnadGenVdsl2VtucPerfLofsread-onlycurrentCount of the number of Loss of Framing failures since agent reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.2ColumnadGenVdsl2VtucPerfLossread-onlycurrentCount of the number of Loss of Signal failures since agent reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.3ColumnadGenVdsl2VtucPerfLolsread-onlycurrentCount of the number of Loss of Link failures since agent reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.4ColumnadGenVdsl2VtucPerfLprsread-onlycurrentCount of the number of Loss of Power failures since agent reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.5ColumnadGenVdsl2VtucPerfEsread-onlycurrentCount of Errored Seconds since the unit was last reset. An Errored Second is a one-second interval containing one or more CRC anomalies, or one or more LOS or …
1.3.6.1.4.1.664.5.65.1.3.1.1.6ColumnadGenVdsl2VtucPerfInitsread-onlycurrentCount of the line initialization attempts since agent reset. Includes both successful and failed attempts.
1.3.6.1.4.1.664.5.65.1.3.1.1.7ColumnadGenVdsl2VtucPerfSesread-onlycurrentCount of Severely Errored Seconds since the unit was last reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.8ColumnadGenVdsl2VtucPerfUasread-onlycurrentCount of Unavailable Seconds since the unit was last reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.9ColumnadGenVdsl2VtucPerfFecsread-onlycurrentCount of the number of FEC Seconds since agent reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.10ColumnadGenVdsl2VtucPerfCrcread-onlycurrentCount of the number of CRC anomolies since agent reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.11ColumnadGenVdsl2VtucPerfFecread-onlycurrentCount of the number of FEC anomolies since agent reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.12ColumnadGenVdsl2VtucPerfValidIntervalsread-onlycurrentThe number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu…
1.3.6.1.4.1.664.5.65.1.3.1.1.13ColumnadGenVdsl2VtucPerfInvalidIntervalsread-onlycurrentThe number of intervals in the range from 0 to the value of adGenVdsl2VtucPerfValidIntervals for which no data is available. This object will typically be zero…
1.3.6.1.4.1.664.5.65.1.3.1.1.14ColumnadGenVdsl2VtucPerfCurr15MinTimeElapsedread-onlycurrentTotal elapsed seconds in this interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.15ColumnadGenVdsl2VtucPerfCurr15MinLofsread-onlycurrentCount of seconds in the current 15 minute interval when there was Loss of Framing.
1.3.6.1.4.1.664.5.65.1.3.1.1.16ColumnadGenVdsl2VtucPerfCurr15MinLossread-onlycurrentCount of seconds in the current 15 minute interval when there was Loss of Signal.
1.3.6.1.4.1.664.5.65.1.3.1.1.17ColumnadGenVdsl2VtucPerfCurr15MinLolsread-onlycurrentCount of seconds in the current 15 minute interval when there was Loss of Link.
1.3.6.1.4.1.664.5.65.1.3.1.1.18ColumnadGenVdsl2VtucPerfCurr15MinLprsread-onlycurrentCount of seconds in the current 15 minute interval when there was Loss of Power.
1.3.6.1.4.1.664.5.65.1.3.1.1.19ColumnadGenVdsl2VtucPerfCurr15MinEsread-onlycurrentCount of Errored Seconds during this interval. An Errored Second is a one-second interval containing one or more CRC anomalies, or one or more LOS or LOF defec…
1.3.6.1.4.1.664.5.65.1.3.1.1.20ColumnadGenVdsl2VtucPerfCurr15MinInitsread-onlycurrentCount of the line initialization attempts in the current 15 minute interval. Includes both successful and failed attempts.
1.3.6.1.4.1.664.5.65.1.3.1.1.21ColumnadGenVdsl2VtucPerfCurr15MinSesread-onlycurrentCount of Severely Errored Seconds in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.22ColumnadGenVdsl2VtucPerfCurr15MinUasread-onlycurrentCount of Unavailable Seconds in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.23ColumnadGenVdsl2VtucPerfCurr15MinFecsread-onlycurrentCount of FEC Seconds in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.24ColumnadGenVdsl2VtucPerfCurr15MinCrcread-onlycurrentCount of CRC anomolies in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.25ColumnadGenVdsl2VtucPerfCurr15MinFecread-onlycurrentCount of FEC anomolies in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.26ColumnadGenVdsl2VtucPerfCurr1DayTimeElapsedread-onlycurrentNumber of seconds that have elapsed since the beginning of the current 1-day interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.27ColumnadGenVdsl2VtucPerfCurr1DayLofsread-onlycurrentCount of the number of seconds when there was Loss of Framing during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.28ColumnadGenVdsl2VtucPerfCurr1DayLossread-onlycurrentCount of the number of seconds when there was Loss of Signal during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.29ColumnadGenVdsl2VtucPerfCurr1DayLolsread-onlycurrentCount of the number of seconds when there was Loss of Link during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.30ColumnadGenVdsl2VtucPerfCurr1DayLprsread-onlycurrentCount of the number of seconds when there was Loss of Power during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.31ColumnadGenVdsl2VtucPerfCurr1DayEsread-onlycurrentCount of Errored Seconds (ES) since the beginning of the current 1-day interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.32ColumnadGenVdsl2VtucPerfCurr1DayInitsread-onlycurrentCount of the line initialization attempts in the day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed. Includes both successful and failed attempts.
1.3.6.1.4.1.664.5.65.1.3.1.1.33ColumnadGenVdsl2VtucPerfCurr1DaySesread-onlycurrentCount of Severely Errored Seconds during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.34ColumnadGenVdsl2VtucPerfCurr1DayUasread-onlycurrentCount of Unavailable Seconds during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.35ColumnadGenVdsl2VtucPerfCurr1DayFecsread-onlycurrentCount of FEC Seconds during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.36ColumnadGenVdsl2VtucPerfCurr1DayCrcread-onlycurrentCount of CRC anomolies during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.37ColumnadGenVdsl2VtucPerfCurr1DayFecread-onlycurrentCount of FEC anomolies during the current day as measured by adGenVdsl2VtucPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.1.1.38ColumnadGenVdsl2VtucPerfTcTxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.39ColumnadGenVdsl2VtucPerfTcTxDataUnitsread-onlycurrentCount of data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.40ColumnadGenVdsl2VtucPerfTcTxDataOctetsread-onlycurrentCount of octets in data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.41ColumnadGenVdsl2VtucPerfTcTxIdleUnitsread-onlycurrentCount of idle/pause transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.42ColumnadGenVdsl2VtucPerfTcRxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.43ColumnadGenVdsl2VtucPerfTcRxDataUnitsread-onlycurrentCount of data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.44ColumnadGenVdsl2VtucPerfTcRxDataOctetsread-onlycurrentCount of octets in data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.45ColumnadGenVdsl2VtucPerfTcRxIdleUnitsread-onlycurrentCount of idle/pause received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.46ColumnadGenVdsl2VtucPerfTcRxErroredUnitsread-onlycurrentCount of errored received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.1.1.47ColumnadGenVdsl2VtucPerfSraDownshiftsread-onlycurrentFree-rolling count of SRA payload rate downshifts since last successful train.
1.3.6.1.4.1.664.5.65.1.3.1.1.48ColumnadGenVdsl2VtucPerfSraUpshiftsread-onlycurrentFree-rolling count of SRA payload rate upshifts since last successful train.
1.3.6.1.4.1.664.5.65.1.3.1.1.49ColumnadGenVdsl2VtucPerfCurr15MinSraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the current 15-min interval
1.3.6.1.4.1.664.5.65.1.3.1.1.50ColumnadGenVdsl2VtucPerfCurr15MinSraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the current 15-min interval
1.3.6.1.4.1.664.5.65.1.3.1.1.51ColumnadGenVdsl2VtucPerfCurr15MinSraRateMaxread-onlycurrentMax payload rate in the current 15-min interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.1.1.52ColumnadGenVdsl2VtucPerfCurr15MinSraRateMinread-onlycurrentMin payload rate in the current 15-min interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.1.1.53ColumnadGenVdsl2VtucPerfCurr1DaySraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the current 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.1.1.54ColumnadGenVdsl2VtucPerfCurr1DaySraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the current 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.1.1.55ColumnadGenVdsl2VtucPerfCurr1DaySraRateMaxread-onlycurrentMax payload rate in the current 24-hr interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.1.1.56ColumnadGenVdsl2VtucPerfCurr1DaySraRateMinread-onlycurrentMin payload rate in the current 24-hr interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.1.1.57ColumnadGenVdsl2VtucPerfRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed since reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.58ColumnadGenVdsl2VtucPerfRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds since reset.
1.3.6.1.4.1.664.5.65.1.3.1.1.59ColumnadGenVdsl2VtucPerfCurr15MinRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed in the current 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.60ColumnadGenVdsl2VtucPerfCurr15MinRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the current 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.61ColumnadGenVdsl2VtucPerfCurr1DayRtxMinEftrread-onlycurrentRetransmission parameter showing the minimum of the error-free throughput rate observed in the current 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.1.1.62ColumnadGenVdsl2VtucPerfCurr1DayRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the current 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.2TableadGenVdsl2VturPerfDataTablenot-accessiblecurrentThis table provides one row for each Vtur. VDSL2 physical interfaces are those ifEntries where ifType is equal to vdsl(97).
1.3.6.1.4.1.664.5.65.1.3.2.1RowadGenVdsl2VturPerfDataEntrynot-accessiblecurrentAn entry in adGenVdsl2VturPerfDataTable.
1.3.6.1.4.1.664.5.65.1.3.2.1.1ColumnadGenVdsl2VturPerfLofsread-onlycurrentCount of the number of Loss of Framing failures since agent reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.2ColumnadGenVdsl2VturPerfLossread-onlycurrentCount of the number of Loss of Signal failures since agent reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.3ColumnadGenVdsl2VturPerfLprsread-onlycurrentCount of the number of Loss of Power failures since agent reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.4ColumnadGenVdsl2VturPerfEsread-onlycurrentCount of Errored Seconds since the unit was last reset. An Errored Second is a one-second interval containing one or more CRC anomalies, or one or more LOS or …
1.3.6.1.4.1.664.5.65.1.3.2.1.5ColumnadGenVdsl2VturPerfSesread-onlycurrentCount of Severely Errored Seconds since the unit was last reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.6ColumnadGenVdsl2VturPerfUasread-onlycurrentCount of Unavailable Seconds since the unit was last reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.7ColumnadGenVdsl2VturPerfFecsread-onlycurrentCount of the number of FEC Seconds since agent reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.8ColumnadGenVdsl2VturPerfCrcread-onlycurrentCount of the number of CRC anomolies since agent reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.9ColumnadGenVdsl2VturPerfFecread-onlycurrentCount of the number of FEC anomolies since agent reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.10ColumnadGenVdsl2VturPerfValidIntervalsread-onlycurrentThe number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu…
1.3.6.1.4.1.664.5.65.1.3.2.1.11ColumnadGenVdsl2VturPerfInvalidIntervalsread-onlycurrentThe number of intervals in the range from 0 to the value of adGenVdsl2VturPerfValidIntervals for which no data is available. This object will typically be zero…
1.3.6.1.4.1.664.5.65.1.3.2.1.12ColumnadGenVdsl2VturPerfCurr15MinTimeElapsedread-onlycurrentTotal elapsed seconds in this interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.13ColumnadGenVdsl2VturPerfCurr15MinLofsread-onlycurrentCount of seconds in the current 15 minute interval when there was Loss of Framing.
1.3.6.1.4.1.664.5.65.1.3.2.1.14ColumnadGenVdsl2VturPerfCurr15MinLossread-onlycurrentCount of seconds in the current 15 minute interval when there was Loss of Signal.
1.3.6.1.4.1.664.5.65.1.3.2.1.15ColumnadGenVdsl2VturPerfCurr15MinLprsread-onlycurrentCount of seconds in the current 15 minute interval when there was Loss of Power.
1.3.6.1.4.1.664.5.65.1.3.2.1.16ColumnadGenVdsl2VturPerfCurr15MinEsread-onlycurrentCount of Errored Seconds in the current 15 minute interval. An Errored Second is a one-second interval containing one or more CRC anomalies, or one or more LOS…
1.3.6.1.4.1.664.5.65.1.3.2.1.17ColumnadGenVdsl2VturPerfCurr15MinSesread-onlycurrentCount of Severely Errored Seconds in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.18ColumnadGenVdsl2VturPerfCurr15MinUasread-onlycurrentCount of Unavailable Seconds in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.19ColumnadGenVdsl2VturPerfCurr15MinFecsread-onlycurrentCount of FEC Seconds in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.20ColumnadGenVdsl2VturPerfCurr15MinCrcread-onlycurrentCount of CRC anomolies in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.21ColumnadGenVdsl2VturPerfCurr15MinFecread-onlycurrentCount of FEC anomolies in the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.22ColumnadGenVdsl2VturPerfCurr1DayTimeElapsedread-onlycurrentNumber of seconds that have elapsed since the beginning of the current 1-day interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.23ColumnadGenVdsl2VturPerfCurr1DayLofsread-onlycurrentCount of the number of seconds when there was Loss of Framing during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.24ColumnadGenVdsl2VturPerfCurr1DayLossread-onlycurrentCount of the number of seconds when there was Loss of Signal during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.25ColumnadGenVdsl2VturPerfCurr1DayLprsread-onlycurrentCount of the number of seconds when there was Loss of Power during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.26ColumnadGenVdsl2VturPerfCurr1DayEsread-onlycurrentCount of the number of seconds when there was Errored Seconds during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.27ColumnadGenVdsl2VturPerfCurr1DaySesread-onlycurrentCount of Severely Errored Seconds during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.28ColumnadGenVdsl2VturPerfCurr1DayUasread-onlycurrentCount of Unavailable Seconds during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.29ColumnadGenVdsl2VturPerfCurr1DayFecsread-onlycurrentCount of FEC Seconds during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.30ColumnadGenVdsl2VturPerfCurr1DayCrcread-onlycurrentCount of CRC anomolies during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.31ColumnadGenVdsl2VturPerfCurr1DayFecread-onlycurrentCount of FEC anomolies during the current day as measured by adGenVdsl2VturPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.2.1.32ColumnadGenVdsl2VturPerfTcTxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.33ColumnadGenVdsl2VturPerfTcTxDataUnitsread-onlycurrentCount of data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.34ColumnadGenVdsl2VturPerfTcTxDataOctetsread-onlycurrentCount of octets in data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.35ColumnadGenVdsl2VturPerfTcTxIdleUnitsread-onlycurrentCount of idle/pause transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.36ColumnadGenVdsl2VturPerfTcRxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.37ColumnadGenVdsl2VturPerfTcRxDataUnitsread-onlycurrentCount of data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.38ColumnadGenVdsl2VturPerfTcRxDataOctetsread-onlycurrentCount of octets in data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.39ColumnadGenVdsl2VturPerfTcRxIdleUnitsread-onlycurrentCount of idle/pause received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.40ColumnadGenVdsl2VturPerfTcRxErroredUnitsread-onlycurrentCount of errored received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.2.1.41ColumnadGenVdsl2VturPerfSraDownshiftsread-onlycurrentFree-rolling count of SRA payload rate downshifts since last successful train.
1.3.6.1.4.1.664.5.65.1.3.2.1.42ColumnadGenVdsl2VturPerfSraUpshiftsread-onlycurrentFree-rolling count of SRA payload rate upshifts since last successful train.
1.3.6.1.4.1.664.5.65.1.3.2.1.43ColumnadGenVdsl2VturPerfCurr15MinSraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the current 15-min interval
1.3.6.1.4.1.664.5.65.1.3.2.1.44ColumnadGenVdsl2VturPerfCurr15MinSraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the current 15-min interval
1.3.6.1.4.1.664.5.65.1.3.2.1.45ColumnadGenVdsl2VturPerfCurr15MinSraRateMaxread-onlycurrentMax payload rate in the current 15-min interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.2.1.46ColumnadGenVdsl2VturPerfCurr15MinSraRateMinread-onlycurrentMin payload rate in the current 15-min interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.2.1.47ColumnadGenVdsl2VturPerfCurr1DaySraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the current 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.2.1.48ColumnadGenVdsl2VturPerfCurr1DaySraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the current 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.2.1.49ColumnadGenVdsl2VturPerfCurr1DaySraRateMaxread-onlycurrentMax payload rate in the current 24-hr interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.2.1.50ColumnadGenVdsl2VturPerfCurr1DaySraRateMinread-onlycurrentMin payload rate in the current 24-hr interval since last successful train. Min and max rate should only be different in the case of an SRA event.
1.3.6.1.4.1.664.5.65.1.3.2.1.51ColumnadGenVdsl2VturPerfRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed since reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.52ColumnadGenVdsl2VturPerfRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds since reset.
1.3.6.1.4.1.664.5.65.1.3.2.1.53ColumnadGenVdsl2VturPerfCurr15MinRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed in the current 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.54ColumnadGenVdsl2VturPerfCurr15MinRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the current 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.55ColumnadGenVdsl2VturPerfCurr1DayRtxMinEftrread-onlycurrentRetransmission parameter showing the minimum of the error-free throughput rate observed in the current 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.2.1.56ColumnadGenVdsl2VturPerfCurr1DayRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the current 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.3TableadGenVdsl2VtucIntervalTablenot-accessiblecurrentThis table provides one row for each Vtuc performance data collection interval. VDSL2 physical interfaces are those ifEntries where ifType is equal to vdsl(97).
1.3.6.1.4.1.664.5.65.1.3.3.1RowadGenVdsl2VtucIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2VtucIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.3.1.1ColumnadGenVdsl2VtucIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
1.3.6.1.4.1.664.5.65.1.3.3.1.2ColumnadGenVdsl2VtucIntervalLofsread-onlycurrentCount of seconds in the interval when there was Loss of Framing.
1.3.6.1.4.1.664.5.65.1.3.3.1.3ColumnadGenVdsl2VtucIntervalLossread-onlycurrentCount of seconds in the interval when there was Loss of Signal.
1.3.6.1.4.1.664.5.65.1.3.3.1.4ColumnadGenVdsl2VtucIntervalLolsread-onlycurrentCount of seconds in the interval when there was Loss of Link.
1.3.6.1.4.1.664.5.65.1.3.3.1.5ColumnadGenVdsl2VtucIntervalLprsread-onlycurrentCount of seconds in the interval when there was Loss of Power.
1.3.6.1.4.1.664.5.65.1.3.3.1.6ColumnadGenVdsl2VtucIntervalESread-onlycurrentCount of Errored Seconds in the interval.
1.3.6.1.4.1.664.5.65.1.3.3.1.7ColumnadGenVdsl2VtucIntervalInitsread-onlycurrentCount of the line initialization attempts during the interval. Includes both successful and failed attempts.
1.3.6.1.4.1.664.5.65.1.3.3.1.8ColumnadGenVdsl2VtucIntervalValidDataread-onlycurrentThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.664.5.65.1.3.3.1.9ColumnadGenVdsl2VtucIntervalSESread-onlycurrentCount of Severely Errored Seconds in the interval.
1.3.6.1.4.1.664.5.65.1.3.3.1.10ColumnadGenVdsl2VtucIntervalUASread-onlycurrentCount of Unavailable Seconds in the interval.
1.3.6.1.4.1.664.5.65.1.3.3.1.11ColumnadGenVdsl2VtucIntervalFECsread-onlycurrentCount of seconds in the interval during which at least one forward error correction event took place.
1.3.6.1.4.1.664.5.65.1.3.3.1.12ColumnadGenVdsl2VtucIntervalFECread-onlycurrentCount of forward error correction events that took place in the interval.
1.3.6.1.4.1.664.5.65.1.3.3.1.13ColumnadGenVdsl2VtucIntervalCRCread-onlycurrentCount of CRC anomolies that took place in the interval.
1.3.6.1.4.1.664.5.65.1.3.3.1.14ColumnadGenVdsl2VtucIntervalSraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the specified 15-min interval
1.3.6.1.4.1.664.5.65.1.3.3.1.15ColumnadGenVdsl2VtucIntervalSraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the specified 15-min interval
1.3.6.1.4.1.664.5.65.1.3.3.1.16ColumnadGenVdsl2VtucIntervalSraRateMaxread-onlycurrentMax payload rate in the specified 15-min interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.3.1.17ColumnadGenVdsl2VtucIntervalSraRateMinread-onlycurrentMin payload rate in the specified 15-min interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.3.1.18ColumnadGenVdsl2VtucIntervalRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed in the specified 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.3.1.19ColumnadGenVdsl2VtucIntervalRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the specified 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.4TableadGenVdsl2VturIntervalTablenot-accessiblecurrentThis table provides one row for each Vtur performance data collection 1 Day interval. VDSL2 physical interfaces are those ifEntries where ifType is equal to vd…
1.3.6.1.4.1.664.5.65.1.3.4.1RowadGenVdsl2VturIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2VturIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.4.1.1ColumnadGenVdsl2VturIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
1.3.6.1.4.1.664.5.65.1.3.4.1.2ColumnadGenVdsl2VturIntervalLofsread-onlycurrentCount of seconds in the interval when there was Loss of Framing.
1.3.6.1.4.1.664.5.65.1.3.4.1.3ColumnadGenVdsl2VturIntervalLossread-onlycurrentCount of seconds in the interval when there was Loss of Signal.
1.3.6.1.4.1.664.5.65.1.3.4.1.4ColumnadGenVdsl2VturIntervalLprsread-onlycurrentCount of seconds in the interval when there was Loss of Power.
1.3.6.1.4.1.664.5.65.1.3.4.1.5ColumnadGenVdsl2VturIntervalESread-onlycurrentCount of Errored Seconds in the interval.
1.3.6.1.4.1.664.5.65.1.3.4.1.6ColumnadGenVdsl2VturIntervalValidDataread-onlycurrentThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.664.5.65.1.3.4.1.7ColumnadGenVdsl2VturIntervalSESread-onlycurrentCount of Severely Errored Seconds in the interval.
1.3.6.1.4.1.664.5.65.1.3.4.1.8ColumnadGenVdsl2VturIntervalUASread-onlycurrentCount of Unavailable Seconds in the interval.
1.3.6.1.4.1.664.5.65.1.3.4.1.9ColumnadGenVdsl2VturIntervalFECsread-onlycurrentCount of seconds in the interval during which at least one forward error correction event took place.
1.3.6.1.4.1.664.5.65.1.3.4.1.10ColumnadGenVdsl2VturIntervalFECread-onlycurrentCount of forward error correction events that took place in the interval.
1.3.6.1.4.1.664.5.65.1.3.4.1.11ColumnadGenVdsl2VturIntervalCRCread-onlycurrentCount of CRC anomolies that took place in the interval.
1.3.6.1.4.1.664.5.65.1.3.4.1.12ColumnadGenVdsl2VturIntervalSraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the specified 15-min interval
1.3.6.1.4.1.664.5.65.1.3.4.1.13ColumnadGenVdsl2VturIntervalSraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the specified 15-min interval
1.3.6.1.4.1.664.5.65.1.3.4.1.14ColumnadGenVdsl2VturIntervalSraRateMaxread-onlycurrentMax payload rate in the specified 15-min interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.4.1.15ColumnadGenVdsl2VturIntervalSraRateMinread-onlycurrentMin payload rate in the specified 15-min interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.4.1.16ColumnadGenVdsl2VturIntervalRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed in the specified 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.4.1.17ColumnadGenVdsl2VturIntervalRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the specified 15-min interval.
1.3.6.1.4.1.664.5.65.1.3.5TableadGenVdsl2VtucChanPerfDataTablenot-accessiblecurrentThis table provides one row for each Vtuc channel. VDSL2 channel interfaces can range from 1 -4
1.3.6.1.4.1.664.5.65.1.3.5.1RowadGenVdsl2VtucChanPerfDataEntrynot-accessiblecurrentAn entry in adGenVdsl2VtucChanPerfDataTable.
1.3.6.1.4.1.664.5.65.1.3.5.1.1ColumnadGenVdsl2VtucChanNumberread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.3.5.1.2ColumnadGenVdsl2VtucChanReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel since agent reset.
1.3.6.1.4.1.664.5.65.1.3.5.1.3ColumnadGenVdsl2VtucChanTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel since agent reset.
1.3.6.1.4.1.664.5.65.1.3.5.1.4ColumnadGenVdsl2VtucChanCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected since agent reset. These blocks are passed on as good data.
1.3.6.1.4.1.664.5.65.1.3.5.1.5ColumnadGenVdsl2VtucChanUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors since agent reset.
1.3.6.1.4.1.664.5.65.1.3.5.1.6ColumnadGenVdsl2VtucChanPerfValidIntervalsread-onlycurrentThe number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu…
1.3.6.1.4.1.664.5.65.1.3.5.1.7ColumnadGenVdsl2VtucChanPerfInvalidIntervalsread-onlycurrentThe number of intervals in the range from 0 to the value of adGenVdsl2VtucChanPerfValidIntervals for which no data is available. This object will typically be …
1.3.6.1.4.1.664.5.65.1.3.5.1.8ColumnadGenVdsl2VtucChanPerfCurr15MinTimeElapsedread-onlycurrentTotal elapsed seconds in this interval.
1.3.6.1.4.1.664.5.65.1.3.5.1.9ColumnadGenVdsl2VtucChanPerfCurr15MinReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.5.1.10ColumnadGenVdsl2VtucChanPerfCurr15MinTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.5.1.11ColumnadGenVdsl2VtucChanPerfCurr15MinCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.5.1.12ColumnadGenVdsl2VtucChanPerfCurr15MinUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.5.1.13ColumnadGenVdsl2VtucChanPerfCurr1DayTimeElapsedread-onlycurrentNumber of seconds that have elapsed since the beginning of the current 1-day interval.
1.3.6.1.4.1.664.5.65.1.3.5.1.14ColumnadGenVdsl2VtucChanPerfCurr1DayReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel during the current day as measured by adGenVdsl2VtucChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.5.1.15ColumnadGenVdsl2VtucChanPerfCurr1DayTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel during the current day as measured by adGenVdsl2VtucChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.5.1.16ColumnadGenVdsl2VtucChanPerfCurr1DayCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel during the current day as measured by adGenVdsl2VtucChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.5.1.17ColumnadGenVdsl2VtucChanPerfCurr1DayUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel during the current day as measured by adGenVdsl2VtucChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.5.1.18ColumnadGenVdsl2VtucChanPerfTcTxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.19ColumnadGenVdsl2VtucChanPerfTcTxDataUnitsread-onlycurrentCount of data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.20ColumnadGenVdsl2VtucChanPerfTcTxDataOctetsread-onlycurrentCount of octets in data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.21ColumnadGenVdsl2VtucChanPerfTcTxIdleUnitsread-onlycurrentCount of idle/pause transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.22ColumnadGenVdsl2VtucChanPerfTcRxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.23ColumnadGenVdsl2VtucChanPerfTcRxDataUnitsread-onlycurrentCount of data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.24ColumnadGenVdsl2VtucChanPerfTcRxDataOctetsread-onlycurrentCount of octets in data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.25ColumnadGenVdsl2VtucChanPerfTcRxIdleUnitsread-onlycurrentCount of idle/pause received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.26ColumnadGenVdsl2VtucChanPerfTcRxErroredUnitsread-onlycurrentCount of errored received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.5.1.27ColumnadGenVdsl2VtucChanPerfRtxUncorrectedDturead-onlycurrentCount of DTUs since reset that have been detected in error and that have not been corrected by one or more retransmissions within the maximum delay constraint.
1.3.6.1.4.1.664.5.65.1.3.5.1.28ColumnadGenVdsl2VtucChanPerfRtxCorrectedDturead-onlycurrentCount of DTUs since reset that have been detected in error and that have been successfully corrected by a retransmission within the maximum delay constraint.
1.3.6.1.4.1.664.5.65.1.3.5.1.29ColumnadGenVdsl2VtucChanPerfRtxRetransmittedDturead-onlycurrentCount of DTUs since reset that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.5.1.30ColumnadGenVdsl2VtucChanPerfCurr15MinRtxUncorrectedDturead-onlycurrentCount of DTUs in the current 15-min interval that have been detected in error and that have not been corrected by one or more retransmissions within the maximu…
1.3.6.1.4.1.664.5.65.1.3.5.1.31ColumnadGenVdsl2VtucChanPerfCurr15MinRtxCorrectedDturead-onlycurrentCount of DTUs in the current 15-min interval that have been detected in error and that have been successfully corrected by a retransmission within the maximum …
1.3.6.1.4.1.664.5.65.1.3.5.1.32ColumnadGenVdsl2VtucChanPerfCurr15MinRtxRetransmittedDturead-onlycurrentCount of DTUs in the current 15-min interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.5.1.33ColumnadGenVdsl2VtucChanPerfCurr1DayRtxUncorrectedDturead-onlycurrentCount of DTUs in the current 24-hr interval that have been detected in error and that have not been corrected by one or more retransmissions within the maximum…
1.3.6.1.4.1.664.5.65.1.3.5.1.34ColumnadGenVdsl2VtucChanPerfCurr1DayRtxCorrectedDturead-onlycurrentCount of DTUs in the current 24-hr interval that have been detected in error and that have been successfully corrected by a retransmission within the maximum d…
1.3.6.1.4.1.664.5.65.1.3.5.1.35ColumnadGenVdsl2VtucChanPerfCurr1DayRtxRetransmittedDturead-onlycurrentCount of DTUs in the current 24-hr interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.6TableadGenVdsl2VturChanPerfDataTablenot-accessiblecurrentThis table provides one row for each Vtur channel. VDSL2 channel interfaces are those ifEntries where ifType is equal to Interleave(124) or Fast(125).
1.3.6.1.4.1.664.5.65.1.3.6.1RowadGenVdsl2VturChanPerfDataEntrynot-accessiblecurrentAn entry in adGenVdsl2VturChanPerfDataTable.
1.3.6.1.4.1.664.5.65.1.3.6.1.1ColumnadGenVdsl2VturChanNumberread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.3.6.1.2ColumnadGenVdsl2VturChanReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel since agent reset.
1.3.6.1.4.1.664.5.65.1.3.6.1.3ColumnadGenVdsl2VturChanTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel since agent reset.
1.3.6.1.4.1.664.5.65.1.3.6.1.4ColumnadGenVdsl2VturChanCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected since agent reset. These blocks are passed on as good data.
1.3.6.1.4.1.664.5.65.1.3.6.1.5ColumnadGenVdsl2VturChanUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors since agent reset.
1.3.6.1.4.1.664.5.65.1.3.6.1.6ColumnadGenVdsl2VturChanPerfValidIntervalsread-onlycurrentThe number of previous 15-minute intervals in the interval table for which data was collected. Given that <n> is the maximum # of intervals supported. The valu…
1.3.6.1.4.1.664.5.65.1.3.6.1.7ColumnadGenVdsl2VturChanPerfInvalidIntervalsread-onlycurrentThe number of intervals in the range from 0 to the value of adGenVdsl2VturChanPerfValidIntervals for which no data is available. This object will typically be …
1.3.6.1.4.1.664.5.65.1.3.6.1.8ColumnadGenVdsl2VturChanPerfCurr15MinTimeElapsedread-onlycurrentTotal elapsed seconds in this interval. A full interval is 900 seconds.
1.3.6.1.4.1.664.5.65.1.3.6.1.9ColumnadGenVdsl2VturChanPerfCurr15MinReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.6.1.10ColumnadGenVdsl2VturChanPerfCurr15MinTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.6.1.11ColumnadGenVdsl2VturChanPerfCurr15MinCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.6.1.12ColumnadGenVdsl2VturChanPerfCurr15MinUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel within the current 15 minute interval.
1.3.6.1.4.1.664.5.65.1.3.6.1.13ColumnadGenVdsl2VturChanPerfCurr1DayTimeElapsedread-onlycurrentNumber of seconds that have elapsed since the beginning of the current 1-day interval.
1.3.6.1.4.1.664.5.65.1.3.6.1.14ColumnadGenVdsl2VturChanPerfCurr1DayReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel during the current day as measured by adGenVdsl2VturChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.6.1.15ColumnadGenVdsl2VturChanPerfCurr1DayTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel during the current day as measured by adGenVdsl2VturChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.6.1.16ColumnadGenVdsl2VturChanPerfCurr1DayCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel during the current day as measured by adGenVdsl2VturChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.6.1.17ColumnadGenVdsl2VturChanPerfCurr1DayUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel during the current day as measured by adGenVdsl2VturChanPerfCurr1DayTimeElapsed.
1.3.6.1.4.1.664.5.65.1.3.6.1.18ColumnadGenVdsl2VturChanPerfTcTxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.19ColumnadGenVdsl2VturChanPerfTcTxDataUnitsread-onlycurrentCount of data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.20ColumnadGenVdsl2VturChanPerfTcTxDataOctetsread-onlycurrentCount of octets in data carrying transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.21ColumnadGenVdsl2VturChanPerfTcTxIdleUnitsread-onlycurrentCount of idle/pause transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.22ColumnadGenVdsl2VturChanPerfTcRxUnitsread-onlycurrentCount of total transmitted transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.23ColumnadGenVdsl2VturChanPerfTcRxDataUnitsread-onlycurrentCount of data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.24ColumnadGenVdsl2VturChanPerfTcRxDataOctetsread-onlycurrentCount of octets in data carrying received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.25ColumnadGenVdsl2VturChanPerfTcRxIdleUnitsread-onlycurrentCount of idle/pause received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.26ColumnadGenVdsl2VturChanPerfTcRxErroredUnitsread-onlycurrentCount of errored received transmission convergence layer (TC) cells (ATM framing mode) or packets (other framing modes).
1.3.6.1.4.1.664.5.65.1.3.6.1.27ColumnadGenVdsl2VturChanPerfRtxUncorrectedDturead-onlycurrentCount of DTUs since reset that have been detected in error and that have not been corrected by one or more retransmissions within the maximum delay constraint.
1.3.6.1.4.1.664.5.65.1.3.6.1.28ColumnadGenVdsl2VturChanPerfRtxCorrectedDturead-onlycurrentCount of DTUs since reset that have been detected in error and that have been successfully corrected by a retransmission within the maximum delay constraint.
1.3.6.1.4.1.664.5.65.1.3.6.1.29ColumnadGenVdsl2VturChanPerfRtxRetransmittedDturead-onlycurrentCount of DTUs since reset that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.6.1.30ColumnadGenVdsl2VturChanPerfCurr15MinRtxUncorrectedDturead-onlycurrentCount of DTUs in the current 15-min interval that have been detected in error and that have not been corrected by one or more retransmissions within the maximu…
1.3.6.1.4.1.664.5.65.1.3.6.1.31ColumnadGenVdsl2VturChanPerfCurr15MinRtxCorrectedDturead-onlycurrentCount of DTUs in the current 15-min interval that have been detected in error and that have been successfully corrected by a retransmission within the maximum …
1.3.6.1.4.1.664.5.65.1.3.6.1.32ColumnadGenVdsl2VturChanPerfCurr15MinRtxRetransmittedDturead-onlycurrentCount of DTUs in the current 15-min interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.6.1.33ColumnadGenVdsl2VturChanPerfCurr1DayRtxUncorrectedDturead-onlycurrentCount of DTUs in the current 24-hr interval that have been detected in error and that have not been corrected by one or more retransmissions within the maximum…
1.3.6.1.4.1.664.5.65.1.3.6.1.34ColumnadGenVdsl2VturChanPerfCurr1DayRtxCorrectedDturead-onlycurrentCount of DTUs in the current 24-hr interval that have been detected in error and that have been successfully corrected by a retransmission within the maximum d…
1.3.6.1.4.1.664.5.65.1.3.6.1.35ColumnadGenVdsl2VturChanPerfCurr1DayRtxRetransmittedDturead-onlycurrentCount of DTUs in the current 24-hr interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.7TableadGenVdsl2VtucChanIntervalTablenot-accessiblecurrentThis table provides one row for each Vtuc channel's performance data collection interval. VDSL2 channel interfaces are those ifEntries where ifType is equal to…
1.3.6.1.4.1.664.5.65.1.3.7.1RowadGenVdsl2VtucChanIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2VtucIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.7.1.1ColumnadGenVdsl2VtucChanNumread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.3.7.1.2ColumnadGenVdsl2VtucChanIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
1.3.6.1.4.1.664.5.65.1.3.7.1.3ColumnadGenVdsl2VtucChanIntervalReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.7.1.4ColumnadGenVdsl2VtucChanIntervalTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.7.1.5ColumnadGenVdsl2VtucChanIntervalCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.7.1.6ColumnadGenVdsl2VtucChanIntervalUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.7.1.7ColumnadGenVdsl2VtucChanIntervalValidDataread-onlycurrentThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.664.5.65.1.3.7.1.8ColumnadGenVdsl2VtucChanIntervalRtxUncorrectedDturead-onlycurrentCount of DTUs in the specified 15-min interval that have been detected in error and that have not been corrected by one or more retransmissions within the maxi…
1.3.6.1.4.1.664.5.65.1.3.7.1.9ColumnadGenVdsl2VtucChanIntervalRtxCorrectedDturead-onlycurrentCount of DTUs in the specified 15-min interval that have been detected in error and that have been successfully corrected by a retransmission within the maximu…
1.3.6.1.4.1.664.5.65.1.3.7.1.10ColumnadGenVdsl2VtucChanIntervalRtxRetransmittedDturead-onlycurrentCount of DTUs in the specified 15-min interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.8TableadGenVdsl2VturChanIntervalTablenot-accessiblecurrentThis table provides one row for each Vtur channel's performance data collection interval. VDSL2 channel interfaces are those ifEntries where ifType is equal to…
1.3.6.1.4.1.664.5.65.1.3.8.1RowadGenVdsl2VturChanIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2VturIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.8.1.1ColumnadGenVdsl2VturChanNumread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.3.8.1.2ColumnadGenVdsl2VturChanIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
1.3.6.1.4.1.664.5.65.1.3.8.1.3ColumnadGenVdsl2VturChanIntervalReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.8.1.4ColumnadGenVdsl2VturChanIntervalTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.8.1.5ColumnadGenVdsl2VturChanIntervalCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.8.1.6ColumnadGenVdsl2VturChanIntervalUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.8.1.7ColumnadGenVdsl2VturChanIntervalValidDataread-onlycurrentThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.664.5.65.1.3.8.1.8ColumnadGenVdsl2VturChanIntervalRtxUncorrectedDturead-onlycurrentCount of DTUs in the specified 15-min interval that have been detected in error and that have not been corrected by one or more retransmissions within the maxi…
1.3.6.1.4.1.664.5.65.1.3.8.1.9ColumnadGenVdsl2VturChanIntervalRtxCorrectedDturead-onlycurrentCount of DTUs in the specified 15-min interval that have been detected in error and that have been successfully corrected by a retransmission within the maximu…
1.3.6.1.4.1.664.5.65.1.3.8.1.10ColumnadGenVdsl2VturChanIntervalRtxRetransmittedDturead-onlycurrentCount of DTUs in the specified 15-min interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.9TableadGenVdsl2Vtuc1DayIntervalTablenot-accessiblecurrentThis table provides one row for each Vtuc performance data collection 1 day interval. VDSL2 physical interfaces are those ifEntries where ifType is equal to vd…
1.3.6.1.4.1.664.5.65.1.3.9.1RowadGenVdsl2Vtuc1DayIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2Vtuc1DayIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.9.1.1ColumnadGenVdsl2Vtuc1DayIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous 1 day interval; interval 7 is 7 Days ago. Intervals 1..7 are optional.
1.3.6.1.4.1.664.5.65.1.3.9.1.2ColumnadGenVdsl2Vtuc1DayIntervalLofsread-onlycurrentCount of seconds in the interval when there was Loss of Framing.
1.3.6.1.4.1.664.5.65.1.3.9.1.3ColumnadGenVdsl2Vtuc1DayIntervalLossread-onlycurrentCount of seconds in the 1 Day interval when there was Loss of Signal.
1.3.6.1.4.1.664.5.65.1.3.9.1.4ColumnadGenVdsl2Vtuc1DayIntervalLolsread-onlycurrentCount of seconds in the 1 Day interval when there was Loss of Link.
1.3.6.1.4.1.664.5.65.1.3.9.1.5ColumnadGenVdsl2Vtuc1DayIntervalLprsread-onlycurrentCount of seconds in the 1 Day interval when there was Loss of Power.
1.3.6.1.4.1.664.5.65.1.3.9.1.6ColumnadGenVdsl2Vtuc1DayIntervalESread-onlycurrentCount of Errored Seconds in the interval.
1.3.6.1.4.1.664.5.65.1.3.9.1.7ColumnadGenVdsl2Vtuc1DayIntervalInitsread-onlycurrentCount of the line initialization attempts during the 1 Day interval. Includes both successful and failed attempts.
1.3.6.1.4.1.664.5.65.1.3.9.1.8ColumnadGenVdsl2Vtuc1DayIntervalValidDataread-onlycurrentThis variable indicates if the data for this 1 Day interval is valid.
1.3.6.1.4.1.664.5.65.1.3.9.1.9ColumnadGenVdsl2Vtuc1DayIntervalSESread-onlycurrentCount of Severely Errored Seconds in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.9.1.10ColumnadGenVdsl2Vtuc1DayIntervalUASread-onlycurrentCount of Unavailable Seconds in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.9.1.11ColumnadGenVdsl2Vtuc1DayIntervalFECsread-onlycurrentCount of seconds in the interval during which at least one forward error correction event took place.
1.3.6.1.4.1.664.5.65.1.3.9.1.12ColumnadGenVdsl2Vtuc1DayIntervalFECread-onlycurrentCount of forward error correction events that took place in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.9.1.13ColumnadGenVdsl2Vtuc1DayIntervalCRCread-onlycurrentCount of CRC anomolies that took place in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.9.1.14ColumnadGenVdsl2Vtuc1DayIntervalSraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the specified 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.9.1.15ColumnadGenVdsl2Vtuc1DayIntervalSraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the specified 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.9.1.16ColumnadGenVdsl2Vtuc1DayIntervalSraRateMaxread-onlycurrentMax payload rate in the specified 24-hr interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.9.1.17ColumnadGenVdsl2Vtuc1DayIntervalSraRateMinread-onlycurrentMin payload rate in the specified 24-hr interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.9.1.18ColumnadGenVdsl2Vtuc1DayIntervalRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed in the specified 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.9.1.19ColumnadGenVdsl2Vtuc1DayIntervalRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the specified 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.10TableadGenVdsl2Vtur1DayIntervalTablenot-accessiblecurrentThis table provides one row for each Vtur performance data collection 1 Day interval. VDSL2 physical interfaces are those ifEntries where ifType is equal to vd…
1.3.6.1.4.1.664.5.65.1.3.10.1RowadGenVdsl2Vtur1DayIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2Vtur1DayIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.10.1.1ColumnadGenVdsl2Vtur1DayIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous 1 day interval; interval 7 is 7 Days ago. Intervals 1..7 are optional.
1.3.6.1.4.1.664.5.65.1.3.10.1.2ColumnadGenVdsl2Vtur1DayIntervalLofsread-onlycurrentCount of seconds in the 1 Day interval when there was Loss of Framing.
1.3.6.1.4.1.664.5.65.1.3.10.1.3ColumnadGenVdsl2Vtur1DayIntervalLossread-onlycurrentCount of seconds in the 1 Day interval when there was Loss of Signal.
1.3.6.1.4.1.664.5.65.1.3.10.1.4ColumnadGenVdsl2Vtur1DayIntervalLprsread-onlycurrentCount of seconds in the 1 Day interval when there was Loss of Power.
1.3.6.1.4.1.664.5.65.1.3.10.1.5ColumnadGenVdsl2Vtur1DayIntervalESread-onlycurrentCount of Errored Seconds in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.10.1.6ColumnadGenVdsl2Vtur1DayIntervalValidDataread-onlycurrentThis variable indicates if the data for this 1 Day interval is valid.
1.3.6.1.4.1.664.5.65.1.3.10.1.7ColumnadGenVdsl2Vtur1DayIntervalSESread-onlycurrentCount of Severely Errored Seconds in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.10.1.8ColumnadGenVdsl2Vtur1DayIntervalUASread-onlycurrentCount of Unavailable Seconds in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.10.1.9ColumnadGenVdsl2Vtur1DayIntervalFECsread-onlycurrentCount of seconds in the 1 Day interval during which at least one forward error correction event took place.
1.3.6.1.4.1.664.5.65.1.3.10.1.10ColumnadGenVdsl2Vtur1DayIntervalFECread-onlycurrentCount of forward error correction events that took place in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.10.1.11ColumnadGenVdsl2Vtur1DayIntervalCRCread-onlycurrentCount of CRC anomolies that took place in the 1 Day interval.
1.3.6.1.4.1.664.5.65.1.3.10.1.12ColumnadGenVdsl2Vtur1DayIntervalSraDownshiftsread-onlycurrentCount of SRA payload rate downshifts since last successful train in the specified 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.10.1.13ColumnadGenVdsl2Vtur1DayIntervalSraUpshiftsread-onlycurrentCount of SRA payload rate upshifts since last successful train in the specified 24-hr interval
1.3.6.1.4.1.664.5.65.1.3.10.1.14ColumnadGenVdsl2Vtur1DayIntervalSraRateMaxread-onlycurrentMax payload rate in the specified 24-hr interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.10.1.15ColumnadGenVdsl2Vtur1DayIntervalSraRateMinread-onlycurrentMin payload rate in the specified 24-hr interval since last successful train.
1.3.6.1.4.1.664.5.65.1.3.10.1.16ColumnadGenVdsl2Vtur1DayIntervalRtxMinEftrread-onlycurrentRetransmission parameter defined as the minimum of the error-free throughput rate observed in the specified 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.10.1.17ColumnadGenVdsl2Vtur1DayIntervalRtxLeftrsread-onlycurrentCount of low error-free throughput rate defect seconds in the specified 24-hr interval.
1.3.6.1.4.1.664.5.65.1.3.11TableadGenVdsl2VtucChan1DayIntervalTablenot-accessiblecurrentThis table provides one row for each Vtuc channel's performance data daily collection intervals. VDSL2 channel interfaces are those ifEntries where ifType is e…
1.3.6.1.4.1.664.5.65.1.3.11.1RowadGenVdsl2VtucChan1DayIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2Vtuc1DayIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.11.1.1ColumnadGenVdsl2Vtuc1DayChanNumread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.3.11.1.2ColumnadGenVdsl2VtucChan1DayIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous interval; interval 7 is 1 week ago. Intervals 2..7 are optional.
1.3.6.1.4.1.664.5.65.1.3.11.1.3ColumnadGenVdsl2VtucChan1DayIntervalReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.11.1.4ColumnadGenVdsl2VtucChan1DayIntervalTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.11.1.5ColumnadGenVdsl2VtucChan1DayIntervalCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.11.1.6ColumnadGenVdsl2VtucChan1DayIntervalUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.11.1.7ColumnadGenVdsl2VtucChan1DayIntervalValidDataread-onlycurrentThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.664.5.65.1.3.11.1.8ColumnadGenVdsl2VtucChan1DayIntervalRtxUncorrectedDturead-onlycurrentCount of DTUs in the specified 24-hr interval that have been detected in error and that have not been corrected by one or more retransmissions within the maxim…
1.3.6.1.4.1.664.5.65.1.3.11.1.9ColumnadGenVdsl2VtucChan1DayIntervalRtxCorrectedDturead-onlycurrentCount of DTUs in the specified 24-hr interval that have been detected in error and that have been successfully corrected by a retransmission within the maximum…
1.3.6.1.4.1.664.5.65.1.3.11.1.10ColumnadGenVdsl2VtucChan1DayIntervalRtxRetransmittedDturead-onlycurrentCount of DTUs in the specified 24-hr interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.3.12TableadGenVdsl2VturChan1DayIntervalTablenot-accessiblecurrentThis table provides one row for each Vtur channel's performance data daily collection interval. VDSL2 channel interfaces are those ifEntries where ifType is eq…
1.3.6.1.4.1.664.5.65.1.3.12.1RowadGenVdsl2VturChan1DayIntervalEntrynot-accessiblecurrentAn entry in the adGenVdsl2Vtur1DayIntervalTable.
1.3.6.1.4.1.664.5.65.1.3.12.1.1ColumnadGenVdsl2Vtur1DayChanNumread-onlycurrentVDSL2 logical channel. Channel values are 1 - 4.
1.3.6.1.4.1.664.5.65.1.3.12.1.2ColumnadGenVdsl2VturChan1DayIntervalNumberread-onlycurrentPerformance Data Interval number 1 is the the most recent previous interval; interval 7 is 1 week ago. Intervals 2..7 are optional.
1.3.6.1.4.1.664.5.65.1.3.12.1.3ColumnadGenVdsl2VturChan1DayIntervalReceivedBlksread-onlycurrentCount of all encoded blocks received on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.12.1.4ColumnadGenVdsl2VturChan1DayIntervalTransmittedBlksread-onlycurrentCount of all encoded blocks transmitted on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.12.1.5ColumnadGenVdsl2VturChan1DayIntervalCorrectedBlksread-onlycurrentCount of all blocks received with errors that were corrected on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.12.1.6ColumnadGenVdsl2VturChan1DayIntervalUncorrectBlksread-onlycurrentCount of all blocks received with uncorrectable errors on this channel during this interval.
1.3.6.1.4.1.664.5.65.1.3.12.1.7ColumnadGenVdsl2VturChan1DayIntervalValidDataread-onlycurrentThis variable indicates if the data for this interval is valid.
1.3.6.1.4.1.664.5.65.1.3.12.1.8ColumnadGenVdsl2VturChan1DayIntervalRtxUncorrectedDturead-onlycurrentCount of DTUs in the specified 24-hr interval that have been detected in error and that have not been corrected by one or more retransmissions within the maxim…
1.3.6.1.4.1.664.5.65.1.3.12.1.9ColumnadGenVdsl2VturChan1DayIntervalRtxCorrectedDturead-onlycurrentCount of DTUs in the specified 24-hr interval that have been detected in error and that have been successfully corrected by a retransmission within the maximum…
1.3.6.1.4.1.664.5.65.1.3.12.1.10ColumnadGenVdsl2VturChan1DayIntervalRtxRetransmittedDturead-onlycurrentCount of DTUs in the specified 24-hr interval that have been retransmitted.
1.3.6.1.4.1.664.5.65.1.4NodeadGenVdsl2Traps
1.3.6.1.4.1.664.5.65.1.4.1NodeadGenVdsl2VtucTrapPrefix
1.3.6.1.4.1.664.5.65.1.4.1.0NodeadGenVdsl2VtucTraps
1.3.6.1.4.1.664.5.65.1.4.1.0.1NotificationadGenVdsl2VtucSnrMgnThreshTrapcurrentSNR Margin threshold reached.
1.3.6.1.4.1.664.5.65.1.4.1.0.2NotificationadGenVdsl2VtucLofsThreshTrapcurrentLoss of Framing 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.1.0.3NotificationadGenVdsl2VtucLossThreshTrapcurrentLoss of Signal 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.1.0.4NotificationadGenVdsl2VtucLolsThreshTrapcurrentLols of Signal 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.1.0.5NotificationadGenVdsl2VtucLprsThreshTrapcurrentLoss of Power 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.1.0.6NotificationadGenVdsl2VtucESThreshTrapcurrentErrored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.1.0.7NotificationadGenVdsl2VtucSESThreshTrapcurrentSeverely Errored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.1.0.8NotificationadGenVdsl2VtucUASThreshTrapcurrentUnavailable Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.2NodeadGenVdsl2VturTrapPrefix
1.3.6.1.4.1.664.5.65.1.4.2.0NodeadGenVdsl2VturTraps
1.3.6.1.4.1.664.5.65.1.4.2.0.1NotificationadGenVdsl2VturSnrMgnThreshTrapcurrentSNR threshold reached.
1.3.6.1.4.1.664.5.65.1.4.2.0.2NotificationadGenVdsl2VturLofsThreshTrapcurrentLoss of Framing 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.2.0.3NotificationadGenVdsl2VturLossThreshTrapcurrentLoss of Signal 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.2.0.4NotificationadGenVdsl2VturLprsThreshTrapcurrentLoss of Power 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.2.0.5NotificationadGenVdsl2VturESThreshTrapcurrentErrored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.2.0.6NotificationadGenVdsl2VturSESThreshTrapcurrentSeverely Errored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.2.0.7NotificationadGenVdsl2VturUASThreshTrapcurrentUnavailable Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3NodeadGenVdsl2VtucTrapPrefixRemote
1.3.6.1.4.1.664.5.65.1.4.3.0NodeadGenVdsl2VtucRemoteTraps
1.3.6.1.4.1.664.5.65.1.4.3.0.1NotificationadGenVdsl2VtucSnrMgnRemoteThreshTrapcurrentSNR Margin threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3.0.2NotificationadGenVdsl2VtucLofsRemoteThreshTrapcurrentLoss of Framing 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3.0.3NotificationadGenVdsl2VtucLossRemoteThreshTrapcurrentLoss of Signal 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3.0.4NotificationadGenVdsl2VtucLolsRemoteThreshTrapcurrentLols of Signal 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3.0.5NotificationadGenVdsl2VtucLprsRemoteThreshTrapcurrentLoss of Power 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3.0.6NotificationadGenVdsl2VtucESRemoteThreshTrapcurrentErrored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3.0.7NotificationadGenVdsl2VtucSESRemoteThreshTrapcurrentSeverely Errored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.3.0.8NotificationadGenVdsl2VtucUASRemoteThreshTrapcurrentUnavailable Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.4NodeadGenVdsl2VturTrapPrefixRemote
1.3.6.1.4.1.664.5.65.1.4.4.0NodeadGenVdsl2VturRemoteTraps
1.3.6.1.4.1.664.5.65.1.4.4.0.1NotificationadGenVdsl2VturSnrMgnRemoteThreshTrapcurrentSNR threshold reached.
1.3.6.1.4.1.664.5.65.1.4.4.0.2NotificationadGenVdsl2VturLofsRemoteThreshTrapcurrentLoss of Framing 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.4.0.3NotificationadGenVdsl2VturLossRemoteThreshTrapcurrentLoss of Signal 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.4.0.4NotificationadGenVdsl2VturLprsRemoteThreshTrapcurrentLoss of Power 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.4.0.5NotificationadGenVdsl2VturESRemoteThreshTrapcurrentErrored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.4.0.6NotificationadGenVdsl2VturSESRemoteThreshTrapcurrentSeverely Errored Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.4.4.0.7NotificationadGenVdsl2VturUASRemoteThreshTrapcurrentUnavailable Second 15-minute interval threshold reached.
1.3.6.1.4.1.664.5.65.1.5NodeadGenVdsl2ExtConfig
1.3.6.1.4.1.664.5.65.1.5.1TableadGenVdsl2ConfProfileExtTablenot-accessiblecurrentThis table contains VDSL management profile configuration information not defined in the adGenVdsl2LineConfProfileTable from the VDSL-LINE-MIB.
1.3.6.1.4.1.664.5.65.1.5.1.1RowadGenVdsl2ConfProfileExtEntrynot-accessiblecurrentAn entry extends the adslLineConfProfileEntry defined in VDSL-LINE-MIB. Each entry corresponds to an VDSL line profile.
1.3.6.1.4.1.664.5.65.1.5.1.1.1ColumnadGenVdsl2LineManagementProfileNameAppliedread-writecurrentManagement profile name applied to the VDSL Port profile.
1.3.6.1.4.1.664.5.65.1.5.1.1.2ColumnadGenVdsl2LineManagementProfileIndexAppliedread-writecurrentManagement profile name applied to the VDSL Port profile.
1.3.6.1.4.1.664.5.65.1.5.1.1.3ColumnadGenVdsl2LineCircuitIDread-writecurrentCircuit ID assigned to VDSL Port.
1.3.6.1.4.1.664.5.65.1.5.1.1.4ColumnadGenVdsl2LineResetCountersread-writecurrentSelection of counter types to reset/clear for the indexed interface. The counter types are performance monitoring intervals (PM history) which typically consis…
1.3.6.1.4.1.664.5.65.1.5.1.1.5ColumnadGenVdsl2LineRetrainRequestread-writecurrentRequest the selected line to perform a full retrain/init or a fast retrain/init. A read will always return full(1).
1.3.6.1.4.1.664.5.65.1.6NodeadGenVdsl2Test
1.3.6.1.4.1.664.5.65.1.7NodeadGenVdsl2MibConformance
1.3.6.1.4.1.664.5.65.1.7.1NodeadGenVdsl2MibGroups
1.3.6.1.4.1.664.5.65.1.7.1.1GroupadGenVdsl2ProvGroupcurrentThese objects provide support for Vdsl2 configuration.
1.3.6.1.4.1.664.5.65.1.7.1.2GroupadGenVdsl2StatusGroupcurrentThese objects provide support for the reporting of status of Vdsl2 physical interfaces, channel, band, and subcarrier.
1.3.6.1.4.1.664.5.65.1.7.1.3GroupadGenVdsl2PMGroupcurrentThese objects provide support for the reporting of the Vdsl2 interface PM data.
1.3.6.1.4.1.664.5.65.1.7.1.4GroupadGenVdsl2TrapsGroupcurrentThese objects provide support for the reporting of the traps from the Vdsl2 interfaces.
1.3.6.1.4.1.664.5.65.1.7.1.5GroupadGenVdsl2ExtConfigGroupcurrentThese objects provide support for Vdsl2 extended profile configuration.
1.3.6.1.4.1.664.6.10000.65.1.1IdentityadGenVdsl2MIBThis MIB defines the objects for the VDSL2 MIB.