This MIB defines the object identifiers (OIDs) for use during factory calibration tests involving TA5000 FXS products.
OIDNameAccessStatusDescription
1.3.6.1.4.1.664.5.67.1.35.1TableadTa5kFxsFacLimitedThlTablenot-accessiblecurrentThe Limited THL test is used during the factory calibration of the TA5000 CPOTS Module (1187160F1). It sends three tones port port towards the CPOTS module, wh…
1.3.6.1.4.1.664.5.67.1.35.1.1RowadTa5kFxsFacLimitedThlEntrynot-accessiblecurrent...
1.3.6.1.4.1.664.5.67.1.35.1.1.1ColumnadTa5kFxsFacLimitedThlStartread-writecurrentUsed to start the test.
1.3.6.1.4.1.664.5.67.1.35.1.1.2ColumnadTa5kFxsFacLimitedThlStatusread-onlycurrentUse to monitor test progress: 1 = na Returned when test has never been run. 2 = complete Returned once test has completed successfully. 3 = fault Returned if t…
1.3.6.1.4.1.664.5.67.1.35.1.1.3ColumnadTa5kFxsFacLimitedThlResultsread-onlycurrentReturns a vector of 32-bit unsigned integers (split into octets containing the measured ERL for each port of the card under test in mdB units. The first uint32…
1.3.6.1.4.1.664.6.10000.67.1.35.1IdentityadTa5kFxsFacIdentityThis MIB defines the object identifiers (OIDs) for use during factory calibration tests involving TA5000 FXS products.