microsens/MICROSENS-CWDM8-MIB
113 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises Gauge IpAddress OBJECT-TYPE TimeTicks |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3181 | Nodemicrosens | |||
| 1.3.6.1.4.1.3181.6 | Nodecwdm | |||
| 1.3.6.1.4.1.3181.6.4 | NodeeightChannelCwdm | |||
| 1.3.6.1.4.1.3181.6.4.0 | NodeminorAlarmRelayTrap | Trap indicating a change in the minor alarm relay status. | ||
| 1.3.6.1.4.1.3181.6.4.1 | TabledeviceTable | not-accessible | mandatory | This table describes the device-status of the CWDM-system. |
| 1.3.6.1.4.1.3181.6.4.1 | NodemajorAlarmRelayTrap | Trap indicating a change in the major alarm relay status. | ||
| 1.3.6.1.4.1.3181.6.4.1.1 | RowdeviceTableEntry | not-accessible | mandatory | An entry in the port table. |
| 1.3.6.1.4.1.3181.6.4.1.1.1 | ColumndeviceId | read-only | mandatory | This entry describes the device id. |
| 1.3.6.1.4.1.3181.6.4.1.1.2 | ColumndeviceArtNo | read-only | mandatory | This entry describes the article number of the device. |
| 1.3.6.1.4.1.3181.6.4.1.1.3 | ColumndeviceSerNo | read-only | mandatory | This entry describes the serial number of the device. |
| 1.3.6.1.4.1.3181.6.4.1.1.4 | ColumndeviceDesc | read-only | mandatory | This entry provides a detailed description of the device. |
| 1.3.6.1.4.1.3181.6.4.1.1.5 | ColumndeviceTemperature | read-only | mandatory | This entry describes the temperature of the device in degree centigrade. |
| 1.3.6.1.4.1.3181.6.4.1.1.6 | ColumndeviceTempAlarmThreshold | read-only | mandatory | This entry describes the current temperature-alarm threshold value of the device in degree centigrade. |
| 1.3.6.1.4.1.3181.6.4.1.1.7 | ColumndeviceTempAlarm | read-only | mandatory | This entry describes if a temperature-alarm condition has occurred or not. |
| 1.3.6.1.4.1.3181.6.4.1.1.8 | ColumndeviceTempShutdown | read-only | mandatory | This entry describes if a temperature-shutdown condition has occurred or not. |
| 1.3.6.1.4.1.3181.6.4.1.1.9 | ColumndeviceTrPowerFailureAlarm | read-only | mandatory | This entry describes if a transceiver-board power-supply-alarm condition has occurred or not. |
| 1.3.6.1.4.1.3181.6.4.1.1.10 | ColumndeviceMinorAlarm | read-only | mandatory | This entry describes if a minor-alarm condition has occurred or not. |
| 1.3.6.1.4.1.3181.6.4.1.1.11 | ColumndeviceMajorAlarm | read-only | mandatory | This entry describes if a major-alarm condition has occurred or not. |
| 1.3.6.1.4.1.3181.6.4.2 | NodedevicePowerSupplyTrap | Trap indicating a change in the power-supply redundancy status. | ||
| 1.3.6.1.4.1.3181.6.4.2 | TableportTable | not-accessible | mandatory | This table describes the port-status of the CWDM-system. |
| 1.3.6.1.4.1.3181.6.4.2.1 | RowportTableEntry | not-accessible | mandatory | An entry in the port table. |
| 1.3.6.1.4.1.3181.6.4.2.1.1 | ColumnportId | read-only | mandatory | This entry describes the port id. |
| 1.3.6.1.4.1.3181.6.4.2.1.2 | ColumnportChannelEnabled | read-only | mandatory | This entry describes the channel's status. A value of 1 indicates that the channel is enabled, a value of 0 indicates that the channel is not enabled. |
| 1.3.6.1.4.1.3181.6.4.2.1.3 | ColumnportLinkThroughLocalLine | read-only | mandatory | This entry describes the local-line link-through-status of the port. |
| 1.3.6.1.4.1.3181.6.4.2.1.4 | ColumnportLinkThroughLineLocal | read-only | mandatory | This entry describes the line-local link-through-status of the port. |
| 1.3.6.1.4.1.3181.6.4.2.1.5 | ColumnportLocalModuleInstalled | read-only | mandatory | This entry describes if a local transceiver module is installed or not. |
| 1.3.6.1.4.1.3181.6.4.2.1.6 | ColumnportLineModuleInstalled | read-only | mandatory | This entry describes if a line transceiver module is installed or not. |
| 1.3.6.1.4.1.3181.6.4.2.1.7 | ColumnportLocalLink | read-only | mandatory | This entry describes the port's local link status. |
| 1.3.6.1.4.1.3181.6.4.2.1.8 | ColumnportLineLink | read-only | mandatory | This entry describes the port's line link status. |
| 1.3.6.1.4.1.3181.6.4.2.1.9 | ColumnportLocalTxFault | read-only | mandatory | This entry describes the port's local-tx-fault status. |
| 1.3.6.1.4.1.3181.6.4.2.1.10 | ColumnportLineTxFault | read-only | mandatory | This entry describes the port's line-tx-fault status. |
| 1.3.6.1.4.1.3181.6.4.2.1.11 | ColumnportLocalPowerFault | read-only | mandatory | This entry describes the port's local-power-fault status. |
| 1.3.6.1.4.1.3181.6.4.2.1.12 | ColumnportLinePowerFault | read-only | mandatory | This entry describes the port's line-power-fault status. |
| 1.3.6.1.4.1.3181.6.4.2.1.13 | ColumnportRateSelect | read-only | mandatory | This entry describes the port's local data rate. A value of 1 describes full data rate, a value of 0 describes reduced data rate. |
| 1.3.6.1.4.1.3181.6.4.3 | NodedeviceTemperatureAlarmTrap | Trap indicating a device temperature alarm event has occurred. | ||
| 1.3.6.1.4.1.3181.6.4.3 | TablelocalModuleTable | not-accessible | mandatory | This table describes the local module status of the CWDM-system. |
| 1.3.6.1.4.1.3181.6.4.3.1 | RowlocalModuleTableEntry | not-accessible | mandatory | An entry in the local module table. |
| 1.3.6.1.4.1.3181.6.4.3.1.1 | ColumnlocalModuleId | read-only | mandatory | This entry describes the local module id. |
| 1.3.6.1.4.1.3181.6.4.3.1.2 | ColumnlocalModuleConnector | read-only | mandatory | This entry describes the connector-type of the port. |
| 1.3.6.1.4.1.3181.6.4.3.1.3 | ColumnlocalModuleTrCodeSonet | read-only | mandatory | This entry describes the SONET compliance of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.3.1.4 | ColumnlocalModuleTrCodeGigabit | read-only | mandatory | This entry describes the Gigabit Ethernet compliance of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.3.1.5 | ColumnlocalModuleTrCodeFbLinkLength | read-only | mandatory | This entry describes the fibre channel link length of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.3.1.6 | ColumnlocalModuleTrCodeFbTrTech | read-only | mandatory | This entry describes the fibre channel transmitter technology of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.3.1.7 | ColumnlocalModuleTrCodeFbTrMedia | read-only | mandatory | This entry describes the fibre channel transmission media of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.3.1.8 | ColumnlocalModuleTrCodeFbSpeed | read-only | mandatory | This entry describes the fibre channel speed of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.3.1.9 | ColumnlocalModuleBrNominal | read-only | mandatory | This entry describes the nominal bit rate, specified in units of 100 Megabits per second. |
| 1.3.6.1.4.1.3181.6.4.3.1.10 | ColumnlocalModuleLength9km | read-only | mandatory | This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the … |
| 1.3.6.1.4.1.3181.6.4.3.1.11 | ColumnlocalModuleLength9m | read-only | mandatory | This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the … |
| 1.3.6.1.4.1.3181.6.4.3.1.12 | ColumnlocalModuleLength50 | read-only | mandatory | This entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 me… |
| 1.3.6.1.4.1.3181.6.4.3.1.13 | ColumnlocalModuleLength62 | read-only | mandatory | This entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 … |
| 1.3.6.1.4.1.3181.6.4.3.1.14 | ColumnlocalModuleLengthCopper | read-only | mandatory | This entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transcei… |
| 1.3.6.1.4.1.3181.6.4.3.1.15 | ColumnlocalModuleVendorSN | read-only | mandatory | This entry describes the vendor's serial number of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.3.1.16 | ColumnlocalModuleDateCode | read-only | mandatory | This entry describes the vendor's date code in the [yymmdd]-format. |
| 1.3.6.1.4.1.3181.6.4.3.1.17 | ColumnlocalModuleLaserCurrent | read-only | optional | This entry describes the transmitter laser's bias current in milli ampere. |
| 1.3.6.1.4.1.3181.6.4.3.1.18 | ColumnlocalModuleTransmittedPower | read-only | optional | This entry describes the transmitter optical output power in micro watt. |
| 1.3.6.1.4.1.3181.6.4.3.1.19 | ColumnlocalModuleReceivedPower | read-only | optional | This entry describes the transmitter optical received power in micro watt. |
| 1.3.6.1.4.1.3181.6.4.3.1.20 | ColumnlocalModuleLaserTemperature | read-only | optional | This entry describes the laser temperature in degree centigrade. |
| 1.3.6.1.4.1.3181.6.4.3.1.21 | ColumnlocalModuleVoltage | read-only | optional | This entry describes the transceiver supply voltage in mV. |
| 1.3.6.1.4.1.3181.6.4.4 | NodedeviceTemperatureShutdownTrap | Trap indicating a device temperature shutdown event has occurred. | ||
| 1.3.6.1.4.1.3181.6.4.4 | TablelineModuleTable | not-accessible | mandatory | This table describes the line module status of the CWDM-system. |
| 1.3.6.1.4.1.3181.6.4.4.1 | RowlineModuleTableEntry | not-accessible | mandatory | An entry in the line module table. |
| 1.3.6.1.4.1.3181.6.4.4.1.1 | ColumnlineModuleId | read-only | mandatory | This entry describes the line module id. |
| 1.3.6.1.4.1.3181.6.4.4.1.2 | ColumnlineModuleConnector | read-only | mandatory | This entry describes the connector-type of the port. |
| 1.3.6.1.4.1.3181.6.4.4.1.3 | ColumnlineModuleTrCodeSonet | read-only | mandatory | This entry describes the SONET compliance of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.4.1.4 | ColumnlineModuleTrCodeGigabit | read-only | mandatory | This entry describes the Gigabit Ethernet compliance of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.4.1.5 | ColumnlineModuleTrCodeFbLinkLength | read-only | mandatory | This entry describes the fibre channel link length of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.4.1.6 | ColumnlineModuleTrCodeFbTrTech | read-only | mandatory | This entry describes the fibre channel transmitter technology of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.4.1.7 | ColumnlineModuleTrCodeFbTrMedia | read-only | mandatory | This entry describes the fibre channel transmission media of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.4.1.8 | ColumnlineModuleTrCodeFbSpeed | read-only | mandatory | This entry describes the fibre channel speed of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.4.1.9 | ColumnlineModuleBrNominal | read-only | mandatory | This entry describes the nominal bit rate, specified in units of 100 Megabits per second. |
| 1.3.6.1.4.1.3181.6.4.4.1.10 | ColumnlineModuleLength9km | read-only | mandatory | This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the … |
| 1.3.6.1.4.1.3181.6.4.4.1.11 | ColumnlineModuleLength9m | read-only | mandatory | This entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the … |
| 1.3.6.1.4.1.3181.6.4.4.1.12 | ColumnlineModuleLength50 | read-only | mandatory | This entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 me… |
| 1.3.6.1.4.1.3181.6.4.4.1.13 | ColumnlineModuleLength62 | read-only | mandatory | This entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 … |
| 1.3.6.1.4.1.3181.6.4.4.1.14 | ColumnlineModuleLengthCopper | read-only | mandatory | This entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transcei… |
| 1.3.6.1.4.1.3181.6.4.4.1.15 | ColumnlineModuleVendorSN | read-only | mandatory | This entry describes the vendor's serial number of the transceiver. |
| 1.3.6.1.4.1.3181.6.4.4.1.16 | ColumnlineModuleDateCode | read-only | mandatory | This entry describes the vendor's date code in the [yymmdd]-format. |
| 1.3.6.1.4.1.3181.6.4.4.1.17 | ColumnlineModuleLaserCurrent | read-only | mandatory | This entry describes the transmitter laser's bias current in milli ampere. |
| 1.3.6.1.4.1.3181.6.4.4.1.18 | ColumnlineModuleTransmittedPower | read-only | mandatory | This entry describes the transmitter optical output power in micro watt. |
| 1.3.6.1.4.1.3181.6.4.4.1.19 | ColumnlineModuleReceivedPower | read-only | mandatory | This entry describes the transmitter optical received power in micro watt. |
| 1.3.6.1.4.1.3181.6.4.4.1.20 | ColumnlineModuleLaserTemperature | read-only | mandatory | This entry describes the laser temperature in degree centigrade. |
| 1.3.6.1.4.1.3181.6.4.4.1.21 | ColumnlineModuleVoltage | read-only | mandatory | This entry describes the transceiver supply voltage in mV. |
| 1.3.6.1.4.1.3181.6.4.5 | NodefanAlarmTrap | Trap indicating a fan alarm in a power supply module. | ||
| 1.3.6.1.4.1.3181.6.4.5 | TablepowerTable | not-accessible | mandatory | This table describes the power-supply-status of the CWDM-system. |
| 1.3.6.1.4.1.3181.6.4.5.1 | RowpowerTableEntry | not-accessible | mandatory | An entry in the power-supply table. |
| 1.3.6.1.4.1.3181.6.4.5.1.1 | ColumnpowerId | read-only | mandatory | This entry describes the power-supply module id. |
| 1.3.6.1.4.1.3181.6.4.5.1.2 | ColumnpowerArtNo | read-only | mandatory | This entry describes the article number of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.5.1.3 | ColumnpowerSerNo | read-only | mandatory | This entry describes the serial number of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.5.1.4 | ColumnpowerDesc | read-only | mandatory | This entry provides a detailed description of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.5.1.5 | ColumnpowerTemperature | read-only | mandatory | This entry describes the temperature of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.5.1.6 | ColumnpowerStatus | read-only | mandatory | This entry describes the operational status of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.5.1.7 | ColumnpowerSuppliedPower | read-only | mandatory | This entry describes the power output of the power-supply module in watt. |
| 1.3.6.1.4.1.3181.6.4.5.1.8 | ColumnpowerLoad | read-only | mandatory | This entry describes the load level of the power-supply module in percent. |
| 1.3.6.1.4.1.3181.6.4.5.1.9 | ColumnpowerFanStatus | read-only | mandatory | This entry describes the fan status of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.6 | TablelineIfTable | not-accessible | mandatory | This table describes the line-interface status of the CWDM-system. |
| 1.3.6.1.4.1.3181.6.4.6 | NodeportLocalLinkChangeTrap | Trap indicating that a port's local link status has changed. The port is identified by the portId variable. | ||
| 1.3.6.1.4.1.3181.6.4.6.1 | RowlineIfTableEntry | not-accessible | mandatory | An entry in the line-interface table. |
| 1.3.6.1.4.1.3181.6.4.6.1.1 | ColumnlineIfId | read-only | mandatory | This entry describes the power-supply module id. |
| 1.3.6.1.4.1.3181.6.4.6.1.2 | ColumnlineIfArtNo | read-only | mandatory | This entry describes the article number of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.6.1.3 | ColumnlineIfSerNo | read-only | mandatory | This entry describes the serial number of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.6.1.4 | ColumnlineIfWestLinkStatus | read-only | optional | This entry describes the west-link status of the interface module. |
| 1.3.6.1.4.1.3181.6.4.6.1.5 | ColumnlineIfEastLinkStatus | read-only | optional | This entry describes the east-link status of the interface module. |
| 1.3.6.1.4.1.3181.6.4.6.1.6 | ColumnlineIfWestChannelStatus | read-only | optional | This entry describes the west-channel status of the interface module. |
| 1.3.6.1.4.1.3181.6.4.6.1.7 | ColumnlineIfEastChannelStatus | read-only | optional | This entry describes the east-channel status of the interface module. |
| 1.3.6.1.4.1.3181.6.4.6.1.8 | ColumnlineIfWestLinkRcvPower | read-only | optional | This entry describes the west-link receive power of the interface module in micro watts. |
| 1.3.6.1.4.1.3181.6.4.6.1.9 | ColumnlineIfEastLinkRcvPower | read-only | optional | This entry describes the east-link receive power of the interface module in micro watts. |
| 1.3.6.1.4.1.3181.6.4.7 | TablepassiveTable | not-accessible | mandatory | This table describes the passive optical module status of the CWDM-system. |
| 1.3.6.1.4.1.3181.6.4.7 | NodeportLineLinkChangeTrap | Trap indicating that a port's line link status has changed. The port is identified by the portId variable. | ||
| 1.3.6.1.4.1.3181.6.4.7.1 | RowpassiveTableEntry | not-accessible | mandatory | An entry in the passive table. |
| 1.3.6.1.4.1.3181.6.4.7.1.1 | ColumnpassiveId | read-only | mandatory | This entry describes the passive optical module id. |
| 1.3.6.1.4.1.3181.6.4.7.1.2 | ColumnpassiveArtNo | read-only | mandatory | This entry describes the article number of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.7.1.3 | ColumnpassiveSerNo | read-only | mandatory | This entry describes the serial number of the power-supply module. |
| 1.3.6.1.4.1.3181.6.4.100 | ScalarchannelCount | read-only | mandatory | This entry describes the number of channels in the CWDM-system. |