microsens/MICROSENS-CWDM8-MIB

113 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.3181Nodemicrosens
1.3.6.1.4.1.3181.6Nodecwdm
1.3.6.1.4.1.3181.6.4NodeeightChannelCwdm
1.3.6.1.4.1.3181.6.4.0NodeminorAlarmRelayTrapTrap indicating a change in the minor alarm relay status.
1.3.6.1.4.1.3181.6.4.1TabledeviceTablenot-accessiblemandatoryThis table describes the device-status of the CWDM-system.
1.3.6.1.4.1.3181.6.4.1NodemajorAlarmRelayTrapTrap indicating a change in the major alarm relay status.
1.3.6.1.4.1.3181.6.4.1.1RowdeviceTableEntrynot-accessiblemandatoryAn entry in the port table.
1.3.6.1.4.1.3181.6.4.1.1.1ColumndeviceIdread-onlymandatoryThis entry describes the device id.
1.3.6.1.4.1.3181.6.4.1.1.2ColumndeviceArtNoread-onlymandatoryThis entry describes the article number of the device.
1.3.6.1.4.1.3181.6.4.1.1.3ColumndeviceSerNoread-onlymandatoryThis entry describes the serial number of the device.
1.3.6.1.4.1.3181.6.4.1.1.4ColumndeviceDescread-onlymandatoryThis entry provides a detailed description of the device.
1.3.6.1.4.1.3181.6.4.1.1.5ColumndeviceTemperatureread-onlymandatoryThis entry describes the temperature of the device in degree centigrade.
1.3.6.1.4.1.3181.6.4.1.1.6ColumndeviceTempAlarmThresholdread-onlymandatoryThis entry describes the current temperature-alarm threshold value of the device in degree centigrade.
1.3.6.1.4.1.3181.6.4.1.1.7ColumndeviceTempAlarmread-onlymandatoryThis entry describes if a temperature-alarm condition has occurred or not.
1.3.6.1.4.1.3181.6.4.1.1.8ColumndeviceTempShutdownread-onlymandatoryThis entry describes if a temperature-shutdown condition has occurred or not.
1.3.6.1.4.1.3181.6.4.1.1.9ColumndeviceTrPowerFailureAlarmread-onlymandatoryThis entry describes if a transceiver-board power-supply-alarm condition has occurred or not.
1.3.6.1.4.1.3181.6.4.1.1.10ColumndeviceMinorAlarmread-onlymandatoryThis entry describes if a minor-alarm condition has occurred or not.
1.3.6.1.4.1.3181.6.4.1.1.11ColumndeviceMajorAlarmread-onlymandatoryThis entry describes if a major-alarm condition has occurred or not.
1.3.6.1.4.1.3181.6.4.2NodedevicePowerSupplyTrapTrap indicating a change in the power-supply redundancy status.
1.3.6.1.4.1.3181.6.4.2TableportTablenot-accessiblemandatoryThis table describes the port-status of the CWDM-system.
1.3.6.1.4.1.3181.6.4.2.1RowportTableEntrynot-accessiblemandatoryAn entry in the port table.
1.3.6.1.4.1.3181.6.4.2.1.1ColumnportIdread-onlymandatoryThis entry describes the port id.
1.3.6.1.4.1.3181.6.4.2.1.2ColumnportChannelEnabledread-onlymandatoryThis entry describes the channel's status. A value of 1 indicates that the channel is enabled, a value of 0 indicates that the channel is not enabled.
1.3.6.1.4.1.3181.6.4.2.1.3ColumnportLinkThroughLocalLineread-onlymandatoryThis entry describes the local-line link-through-status of the port.
1.3.6.1.4.1.3181.6.4.2.1.4ColumnportLinkThroughLineLocalread-onlymandatoryThis entry describes the line-local link-through-status of the port.
1.3.6.1.4.1.3181.6.4.2.1.5ColumnportLocalModuleInstalledread-onlymandatoryThis entry describes if a local transceiver module is installed or not.
1.3.6.1.4.1.3181.6.4.2.1.6ColumnportLineModuleInstalledread-onlymandatoryThis entry describes if a line transceiver module is installed or not.
1.3.6.1.4.1.3181.6.4.2.1.7ColumnportLocalLinkread-onlymandatoryThis entry describes the port's local link status.
1.3.6.1.4.1.3181.6.4.2.1.8ColumnportLineLinkread-onlymandatoryThis entry describes the port's line link status.
1.3.6.1.4.1.3181.6.4.2.1.9ColumnportLocalTxFaultread-onlymandatoryThis entry describes the port's local-tx-fault status.
1.3.6.1.4.1.3181.6.4.2.1.10ColumnportLineTxFaultread-onlymandatoryThis entry describes the port's line-tx-fault status.
1.3.6.1.4.1.3181.6.4.2.1.11ColumnportLocalPowerFaultread-onlymandatoryThis entry describes the port's local-power-fault status.
1.3.6.1.4.1.3181.6.4.2.1.12ColumnportLinePowerFaultread-onlymandatoryThis entry describes the port's line-power-fault status.
1.3.6.1.4.1.3181.6.4.2.1.13ColumnportRateSelectread-onlymandatoryThis entry describes the port's local data rate. A value of 1 describes full data rate, a value of 0 describes reduced data rate.
1.3.6.1.4.1.3181.6.4.3NodedeviceTemperatureAlarmTrapTrap indicating a device temperature alarm event has occurred.
1.3.6.1.4.1.3181.6.4.3TablelocalModuleTablenot-accessiblemandatoryThis table describes the local module status of the CWDM-system.
1.3.6.1.4.1.3181.6.4.3.1RowlocalModuleTableEntrynot-accessiblemandatoryAn entry in the local module table.
1.3.6.1.4.1.3181.6.4.3.1.1ColumnlocalModuleIdread-onlymandatoryThis entry describes the local module id.
1.3.6.1.4.1.3181.6.4.3.1.2ColumnlocalModuleConnectorread-onlymandatoryThis entry describes the connector-type of the port.
1.3.6.1.4.1.3181.6.4.3.1.3ColumnlocalModuleTrCodeSonetread-onlymandatoryThis entry describes the SONET compliance of the transceiver.
1.3.6.1.4.1.3181.6.4.3.1.4ColumnlocalModuleTrCodeGigabitread-onlymandatoryThis entry describes the Gigabit Ethernet compliance of the transceiver.
1.3.6.1.4.1.3181.6.4.3.1.5ColumnlocalModuleTrCodeFbLinkLengthread-onlymandatoryThis entry describes the fibre channel link length of the transceiver.
1.3.6.1.4.1.3181.6.4.3.1.6ColumnlocalModuleTrCodeFbTrTechread-onlymandatoryThis entry describes the fibre channel transmitter technology of the transceiver.
1.3.6.1.4.1.3181.6.4.3.1.7ColumnlocalModuleTrCodeFbTrMediaread-onlymandatoryThis entry describes the fibre channel transmission media of the transceiver.
1.3.6.1.4.1.3181.6.4.3.1.8ColumnlocalModuleTrCodeFbSpeedread-onlymandatoryThis entry describes the fibre channel speed of the transceiver.
1.3.6.1.4.1.3181.6.4.3.1.9ColumnlocalModuleBrNominalread-onlymandatoryThis entry describes the nominal bit rate, specified in units of 100 Megabits per second.
1.3.6.1.4.1.3181.6.4.3.1.10ColumnlocalModuleLength9kmread-onlymandatoryThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the …
1.3.6.1.4.1.3181.6.4.3.1.11ColumnlocalModuleLength9mread-onlymandatoryThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the …
1.3.6.1.4.1.3181.6.4.3.1.12ColumnlocalModuleLength50read-onlymandatoryThis entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 me…
1.3.6.1.4.1.3181.6.4.3.1.13ColumnlocalModuleLength62read-onlymandatoryThis entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 …
1.3.6.1.4.1.3181.6.4.3.1.14ColumnlocalModuleLengthCopperread-onlymandatoryThis entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transcei…
1.3.6.1.4.1.3181.6.4.3.1.15ColumnlocalModuleVendorSNread-onlymandatoryThis entry describes the vendor's serial number of the transceiver.
1.3.6.1.4.1.3181.6.4.3.1.16ColumnlocalModuleDateCoderead-onlymandatoryThis entry describes the vendor's date code in the [yymmdd]-format.
1.3.6.1.4.1.3181.6.4.3.1.17ColumnlocalModuleLaserCurrentread-onlyoptionalThis entry describes the transmitter laser's bias current in milli ampere.
1.3.6.1.4.1.3181.6.4.3.1.18ColumnlocalModuleTransmittedPowerread-onlyoptionalThis entry describes the transmitter optical output power in micro watt.
1.3.6.1.4.1.3181.6.4.3.1.19ColumnlocalModuleReceivedPowerread-onlyoptionalThis entry describes the transmitter optical received power in micro watt.
1.3.6.1.4.1.3181.6.4.3.1.20ColumnlocalModuleLaserTemperatureread-onlyoptionalThis entry describes the laser temperature in degree centigrade.
1.3.6.1.4.1.3181.6.4.3.1.21ColumnlocalModuleVoltageread-onlyoptionalThis entry describes the transceiver supply voltage in mV.
1.3.6.1.4.1.3181.6.4.4NodedeviceTemperatureShutdownTrapTrap indicating a device temperature shutdown event has occurred.
1.3.6.1.4.1.3181.6.4.4TablelineModuleTablenot-accessiblemandatoryThis table describes the line module status of the CWDM-system.
1.3.6.1.4.1.3181.6.4.4.1RowlineModuleTableEntrynot-accessiblemandatoryAn entry in the line module table.
1.3.6.1.4.1.3181.6.4.4.1.1ColumnlineModuleIdread-onlymandatoryThis entry describes the line module id.
1.3.6.1.4.1.3181.6.4.4.1.2ColumnlineModuleConnectorread-onlymandatoryThis entry describes the connector-type of the port.
1.3.6.1.4.1.3181.6.4.4.1.3ColumnlineModuleTrCodeSonetread-onlymandatoryThis entry describes the SONET compliance of the transceiver.
1.3.6.1.4.1.3181.6.4.4.1.4ColumnlineModuleTrCodeGigabitread-onlymandatoryThis entry describes the Gigabit Ethernet compliance of the transceiver.
1.3.6.1.4.1.3181.6.4.4.1.5ColumnlineModuleTrCodeFbLinkLengthread-onlymandatoryThis entry describes the fibre channel link length of the transceiver.
1.3.6.1.4.1.3181.6.4.4.1.6ColumnlineModuleTrCodeFbTrTechread-onlymandatoryThis entry describes the fibre channel transmitter technology of the transceiver.
1.3.6.1.4.1.3181.6.4.4.1.7ColumnlineModuleTrCodeFbTrMediaread-onlymandatoryThis entry describes the fibre channel transmission media of the transceiver.
1.3.6.1.4.1.3181.6.4.4.1.8ColumnlineModuleTrCodeFbSpeedread-onlymandatoryThis entry describes the fibre channel speed of the transceiver.
1.3.6.1.4.1.3181.6.4.4.1.9ColumnlineModuleBrNominalread-onlymandatoryThis entry describes the nominal bit rate, specified in units of 100 Megabits per second.
1.3.6.1.4.1.3181.6.4.4.1.10ColumnlineModuleLength9kmread-onlymandatoryThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the …
1.3.6.1.4.1.3181.6.4.4.1.11ColumnlineModuleLength9mread-onlymandatoryThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the …
1.3.6.1.4.1.3181.6.4.4.1.12ColumnlineModuleLength50read-onlymandatoryThis entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 me…
1.3.6.1.4.1.3181.6.4.4.1.13ColumnlineModuleLength62read-onlymandatoryThis entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 …
1.3.6.1.4.1.3181.6.4.4.1.14ColumnlineModuleLengthCopperread-onlymandatoryThis entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transcei…
1.3.6.1.4.1.3181.6.4.4.1.15ColumnlineModuleVendorSNread-onlymandatoryThis entry describes the vendor's serial number of the transceiver.
1.3.6.1.4.1.3181.6.4.4.1.16ColumnlineModuleDateCoderead-onlymandatoryThis entry describes the vendor's date code in the [yymmdd]-format.
1.3.6.1.4.1.3181.6.4.4.1.17ColumnlineModuleLaserCurrentread-onlymandatoryThis entry describes the transmitter laser's bias current in milli ampere.
1.3.6.1.4.1.3181.6.4.4.1.18ColumnlineModuleTransmittedPowerread-onlymandatoryThis entry describes the transmitter optical output power in micro watt.
1.3.6.1.4.1.3181.6.4.4.1.19ColumnlineModuleReceivedPowerread-onlymandatoryThis entry describes the transmitter optical received power in micro watt.
1.3.6.1.4.1.3181.6.4.4.1.20ColumnlineModuleLaserTemperatureread-onlymandatoryThis entry describes the laser temperature in degree centigrade.
1.3.6.1.4.1.3181.6.4.4.1.21ColumnlineModuleVoltageread-onlymandatoryThis entry describes the transceiver supply voltage in mV.
1.3.6.1.4.1.3181.6.4.5NodefanAlarmTrapTrap indicating a fan alarm in a power supply module.
1.3.6.1.4.1.3181.6.4.5TablepowerTablenot-accessiblemandatoryThis table describes the power-supply-status of the CWDM-system.
1.3.6.1.4.1.3181.6.4.5.1RowpowerTableEntrynot-accessiblemandatoryAn entry in the power-supply table.
1.3.6.1.4.1.3181.6.4.5.1.1ColumnpowerIdread-onlymandatoryThis entry describes the power-supply module id.
1.3.6.1.4.1.3181.6.4.5.1.2ColumnpowerArtNoread-onlymandatoryThis entry describes the article number of the power-supply module.
1.3.6.1.4.1.3181.6.4.5.1.3ColumnpowerSerNoread-onlymandatoryThis entry describes the serial number of the power-supply module.
1.3.6.1.4.1.3181.6.4.5.1.4ColumnpowerDescread-onlymandatoryThis entry provides a detailed description of the power-supply module.
1.3.6.1.4.1.3181.6.4.5.1.5ColumnpowerTemperatureread-onlymandatoryThis entry describes the temperature of the power-supply module.
1.3.6.1.4.1.3181.6.4.5.1.6ColumnpowerStatusread-onlymandatoryThis entry describes the operational status of the power-supply module.
1.3.6.1.4.1.3181.6.4.5.1.7ColumnpowerSuppliedPowerread-onlymandatoryThis entry describes the power output of the power-supply module in watt.
1.3.6.1.4.1.3181.6.4.5.1.8ColumnpowerLoadread-onlymandatoryThis entry describes the load level of the power-supply module in percent.
1.3.6.1.4.1.3181.6.4.5.1.9ColumnpowerFanStatusread-onlymandatoryThis entry describes the fan status of the power-supply module.
1.3.6.1.4.1.3181.6.4.6TablelineIfTablenot-accessiblemandatoryThis table describes the line-interface status of the CWDM-system.
1.3.6.1.4.1.3181.6.4.6NodeportLocalLinkChangeTrapTrap indicating that a port's local link status has changed. The port is identified by the portId variable.
1.3.6.1.4.1.3181.6.4.6.1RowlineIfTableEntrynot-accessiblemandatoryAn entry in the line-interface table.
1.3.6.1.4.1.3181.6.4.6.1.1ColumnlineIfIdread-onlymandatoryThis entry describes the power-supply module id.
1.3.6.1.4.1.3181.6.4.6.1.2ColumnlineIfArtNoread-onlymandatoryThis entry describes the article number of the power-supply module.
1.3.6.1.4.1.3181.6.4.6.1.3ColumnlineIfSerNoread-onlymandatoryThis entry describes the serial number of the power-supply module.
1.3.6.1.4.1.3181.6.4.6.1.4ColumnlineIfWestLinkStatusread-onlyoptionalThis entry describes the west-link status of the interface module.
1.3.6.1.4.1.3181.6.4.6.1.5ColumnlineIfEastLinkStatusread-onlyoptionalThis entry describes the east-link status of the interface module.
1.3.6.1.4.1.3181.6.4.6.1.6ColumnlineIfWestChannelStatusread-onlyoptionalThis entry describes the west-channel status of the interface module.
1.3.6.1.4.1.3181.6.4.6.1.7ColumnlineIfEastChannelStatusread-onlyoptionalThis entry describes the east-channel status of the interface module.
1.3.6.1.4.1.3181.6.4.6.1.8ColumnlineIfWestLinkRcvPowerread-onlyoptionalThis entry describes the west-link receive power of the interface module in micro watts.
1.3.6.1.4.1.3181.6.4.6.1.9ColumnlineIfEastLinkRcvPowerread-onlyoptionalThis entry describes the east-link receive power of the interface module in micro watts.
1.3.6.1.4.1.3181.6.4.7TablepassiveTablenot-accessiblemandatoryThis table describes the passive optical module status of the CWDM-system.
1.3.6.1.4.1.3181.6.4.7NodeportLineLinkChangeTrapTrap indicating that a port's line link status has changed. The port is identified by the portId variable.
1.3.6.1.4.1.3181.6.4.7.1RowpassiveTableEntrynot-accessiblemandatoryAn entry in the passive table.
1.3.6.1.4.1.3181.6.4.7.1.1ColumnpassiveIdread-onlymandatoryThis entry describes the passive optical module id.
1.3.6.1.4.1.3181.6.4.7.1.2ColumnpassiveArtNoread-onlymandatoryThis entry describes the article number of the power-supply module.
1.3.6.1.4.1.3181.6.4.7.1.3ColumnpassiveSerNoread-onlymandatoryThis entry describes the serial number of the power-supply module.
1.3.6.1.4.1.3181.6.4.100ScalarchannelCountread-onlymandatoryThis entry describes the number of channels in the CWDM-system.