MIB Viewer

jnxSoamDmCfgNumMeasBinsPerFrameDelayRangeInterval

OBJECT-TYPE
1.3.6.1.4.1.2636.3.78.1.3.1.1.34
Access
read-create
Status
current
Sub-identifiers
0
This object specifies the number of measurement bins per Measurement Interval for Frame Delay Range measurements. At least 2 bins are to be supported; at least 10 bins are recommended to be supported. This object can only be written at row creation time and cannot be modified once it has been created.
Unsigned32 (2..100)