MIB Viewer

prvtEfmOamEventConfigErrorSymbolPeriodWindow

OBJECT-TYPE
1.3.6.1.4.1.738.1.5.133.1.21.1.1
Access
read-write
Status
current
Sub-identifiers
0
If prvtEfmOamEventConfigErrorSymbolPeriodThreshold symbol errors occur within a window of prvtEfmOamEventConfigErrorSymbolPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating that the threshold has been crossed in this window.
Unsigned32 (1..60)