MIB Viewer

tmnxDot1agCfmMepOWDTTargetMepId

OBJECT-TYPE
1.3.6.1.4.1.6527.3.1.2.52.7.1.1.48
Access
read-create
Status
current
Sub-identifiers
0
The value of tmnxDot1agCfmMepOWDTTargetMepId specifies the Maintenance association End Point Identifier (MepId) of another MEP in the same Maintenance Association that the One-Way-Delay Test frames will be sent to. If the tmnxDot1agCfmMepOWDTTargetMepId is set then a local lookup for the target MEP destination MAC address will be performed when the test is started. Note that a valid target destination MAC address must be found for proper execution of the one-way-delay-test if the tmnxDot1agCfmMepOWDTTargetMepId is being used as the input for the test. The tmnxDot1agCfmMepOWDTTargetMepId cannot be set if the tmnxDot1agCfmMepOWDTMacAddress is set to a non-zero value. Setting this object will trigger the test frame to be sent. Once the test is complete, the object will revert to the default value, indicating that another test is possible.
Dot1agCfmMepIdOrZero