MIB Viewer

tmnxWlanGwQosRadiusGtpMismatch

NOTIFICATION-TYPE
1.3.6.1.4.1.6527.3.1.3.81.0.14
Status
current
Sub-identifiers
0
The tmnxWlanGwQosRadiusGtpMismatch notification is sent when the Negotiated QoS profile RADIUS attribute contains a release indicator either for GGSN or PGW that does not correspond to the interface type actually used in GTP. e.g. the release indicator is for GGSN and the interface type used in GTP is S2a/S2b while it should be Gn. [CAUSE] Inconsistency between the release indicator in the RADIUS attribute and the GTP interface type. [EFFECT] The QoS values in the tmnxWlanGwPgwTable or the tmnxWlanGwGgsnTable of the conceptual row corresponding to the row in the tmnxWlanGwMgwAddrTable that matches the WLAN are used instead. [RECOVERY] The RADIUS Server configuration should be corrected.