vRtrMplsGenSrTeResignalTimer

OBJECT-TYPE
1.3.6.1.4.1.6527.3.1.2.6.7.1.50
Access
read-create
Status
current
Sub-identifiers
0
The value of vRtrMplsGenSrTeResignalTimer specifies the value for the SR-TE LSPs resignal timer, that is the time, in minutes, the software will wait before attempting to resignal the SR-TE LSPs. When the resignal timer expires, if the new recorded hop list (RRO) for an SR-TE LSP has a better metric than the current recorded hop list, an attempt will be made to resignal that LSP using the make-before-break mechanism. If the attempt to resignal an SR-TE LSP fails, the LSP will continue to use the existing path and a resignal will be attempted the next time the timer expires. A value of 0 for the resignal timer indicates that timer-based SR-TE LSP resignalling has been disabled.
Unsigned32 (0 | 30..10080)