MIB Viewer

A3COM-SWITCHING-SYSTEMS-POLL-MIB

29 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.43Nodea3Com
1.3.6.1.4.1.43.29NodeswitchingSystemsMibs
1.3.6.1.4.1.43.29.4Nodea3ComSwitchingSystemsMib
1.3.6.1.4.1.43.29.4.22Nodea3ComPoll
1.3.6.1.4.1.43.29.4.22.1Tablea3ComPollTablenot-accessiblemandatoryThis table is used to provide remote device monitoring facilities. The implementation allows a list of network devices to be set up and polled regularly (or on…
1.3.6.1.4.1.43.29.4.22.1.1Rowa3ComPollEntrynot-accessiblemandatoryA table used to define device monitoring. A row in this table is created by setting any read-write member, indexed by the next available index (a3ComPollNextFr…
1.3.6.1.4.1.43.29.4.22.1.1.1Columna3ComPollIndexread-onlymandatoryUnique identifier of a row in the Poll Table. The actual number of rows that can be created on any particular device depends on the memory and processing resou…
1.3.6.1.4.1.43.29.4.22.1.1.2Columna3ComPollAddressread-writemandatoryThis DisplayString is the network address of the device to monitor. Typically this is an IP, dotted IP format, IP's hostname, IPX or AppleTalk. The following f…
1.3.6.1.4.1.43.29.4.22.1.1.3Columna3ComPollAddressTyperead-writemandatoryThis defines the method used to interpret the a3ComPollAddress, which implies on the protocol to be used. Writing an address to the a3ComPollAddress object cau…
1.3.6.1.4.1.43.29.4.22.1.1.4Columna3ComPollCountread-writemandatoryThis integer is the number of ping packets to be sent out until completion of a polling command. If count is set to continuous(0), the remote device will be ke…
1.3.6.1.4.1.43.29.4.22.1.1.5Columna3ComPollAttemptsread-writemandatoryThe number of unsuccessful or successful requests necessary before deciding that the device is definitely not responding or responding. In order to use traps, …
1.3.6.1.4.1.43.29.4.22.1.1.6Columna3ComPollRateread-writemandatoryThis defines how often, in seconds, a poll packet is sent to the device being polled. If burst mode(0) is chosen, then number of packets selected will be sent …
1.3.6.1.4.1.43.29.4.22.1.1.7Columna3ComPollResponseTimeOutread-writemandatoryMaximum wait time, in msecs, for a response packet before deciding that no response arrived. This object differs from a3ComPollRate as the device have the send…
1.3.6.1.4.1.43.29.4.22.1.1.8Columna3ComPollPacketSizeread-writemandatorySize, in bytes, of ping packet to be sent out. If set to 0, the default size for ping packet under the protocol chosen will be used. If value given is to too l…
1.3.6.1.4.1.43.29.4.22.1.1.9Columna3ComPollSourceAddressread-writemandatoryThis DisplayString is the network address of the local interface to receive ping query. Typically this is an IP, IPX or AppleTalk. The following formats can be…
1.3.6.1.4.1.43.29.4.22.1.1.10Columna3ComPollMinRoundTripTimeread-onlymandatoryThe minimum amount of time taken, in msecs, for the round trip of a ping packet.
1.3.6.1.4.1.43.29.4.22.1.1.11Columna3ComPollAvgRoundTripTimeread-onlymandatoryThe average amount of time taken, in msecs, for the round trip of a ping packet.
1.3.6.1.4.1.43.29.4.22.1.1.12Columna3ComPollMaxRoundTripTimeread-onlymandatoryThe maximum amount of time taken, in msecs, for the round trip of a ping packet.
1.3.6.1.4.1.43.29.4.22.1.1.13Columna3ComPollFramesSentread-onlymandatoryThe number of ping packets sent to remote device so far.
1.3.6.1.4.1.43.29.4.22.1.1.14Columna3ComPollFramesReceivedread-onlymandatoryThe number of ping packets responded by remote device so far. If a3ComPollResponseTimeOut is a non-zero value, and the poll response arrives after the specifie…
1.3.6.1.4.1.43.29.4.22.1.1.15Columna3ComPollInformationread-onlymandatoryDepending on the protocol being used, this object contains extra information obtained through the device poll. For IP, the value is the number of packets that …
1.3.6.1.4.1.43.29.4.22.1.1.16Columna3ComPollOwnerread-writemandatoryThe RMON OwnerString conventions are used here to help control the multi-manager situations.
1.3.6.1.4.1.43.29.4.22.1.1.17Columna3ComPollReportread-onlymandatoryThis integer contains the current status of the poll entry. When the state changes from busy to any other, the entry is no longer active. In situations where t…
1.3.6.1.4.1.43.29.4.22.1.1.18Columna3ComPollActionread-writemandatoryThis object is the trigger for initiating, stopping, resetting and destroying a poll entry. In order to read the current status of an entry, a3ComPollReport is…
1.3.6.1.4.1.43.29.4.22.2Scalara3ComPollNextFreeIndexread-onlymandatoryThe index for the next available remote polling entry in the table.
1.3.6.1.4.1.43.29.4.22.3Scalara3ComPollTableInformationread-onlymandatoryThis object provides a summary on the entire poll table. Internal thresholds, such as the maximum number of entries, as well the number of entries that can be …
1.3.6.1.4.1.43.29.4.22.4Scalara3ComPollTableActionAllread-writemandatoryThis object works exactly as a3ComPollAction, except that it affects every entry in the table, in one snmp transaction. If a3ComPollTableActionAll is called wi…
1.3.6.1.4.1.43.29.4.61Nodea3ComPollResponseReceivedThis trap is generated when the PollTable in the managed agent receives replies to a poll after a sequence of unsuccessful polls. The number of packets in such…
1.3.6.1.4.1.43.29.4.62Nodea3ComPollResponseNotReceivedThis trap is generated when the PollTable in the managed agent receives no replies to a poll after a sequence of successful polls. The number of packets in suc…