A3COM-SWITCHING-SYSTEMS-POLL-MIB
29 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.43 | Nodea3Com | |||
| 1.3.6.1.4.1.43.29 | NodeswitchingSystemsMibs | |||
| 1.3.6.1.4.1.43.29.4 | Nodea3ComSwitchingSystemsMib | |||
| 1.3.6.1.4.1.43.29.4.22 | Nodea3ComPoll | |||
| 1.3.6.1.4.1.43.29.4.22.1 | Tablea3ComPollTable | not-accessible | mandatory | This table is used to provide remote device monitoring facilities. The implementation allows a list of network devices to be set up and polled regularly (or on… |
| 1.3.6.1.4.1.43.29.4.22.1.1 | Rowa3ComPollEntry | not-accessible | mandatory | A table used to define device monitoring. A row in this table is created by setting any read-write member, indexed by the next available index (a3ComPollNextFr… |
| 1.3.6.1.4.1.43.29.4.22.1.1.1 | Columna3ComPollIndex | read-only | mandatory | Unique identifier of a row in the Poll Table. The actual number of rows that can be created on any particular device depends on the memory and processing resou… |
| 1.3.6.1.4.1.43.29.4.22.1.1.2 | Columna3ComPollAddress | read-write | mandatory | This DisplayString is the network address of the device to monitor. Typically this is an IP, dotted IP format, IP's hostname, IPX or AppleTalk. The following f… |
| 1.3.6.1.4.1.43.29.4.22.1.1.3 | Columna3ComPollAddressType | read-write | mandatory | This defines the method used to interpret the a3ComPollAddress, which implies on the protocol to be used. Writing an address to the a3ComPollAddress object cau… |
| 1.3.6.1.4.1.43.29.4.22.1.1.4 | Columna3ComPollCount | read-write | mandatory | This integer is the number of ping packets to be sent out until completion of a polling command. If count is set to continuous(0), the remote device will be ke… |
| 1.3.6.1.4.1.43.29.4.22.1.1.5 | Columna3ComPollAttempts | read-write | mandatory | The number of unsuccessful or successful requests necessary before deciding that the device is definitely not responding or responding. In order to use traps, … |
| 1.3.6.1.4.1.43.29.4.22.1.1.6 | Columna3ComPollRate | read-write | mandatory | This defines how often, in seconds, a poll packet is sent to the device being polled. If burst mode(0) is chosen, then number of packets selected will be sent … |
| 1.3.6.1.4.1.43.29.4.22.1.1.7 | Columna3ComPollResponseTimeOut | read-write | mandatory | Maximum wait time, in msecs, for a response packet before deciding that no response arrived. This object differs from a3ComPollRate as the device have the send… |
| 1.3.6.1.4.1.43.29.4.22.1.1.8 | Columna3ComPollPacketSize | read-write | mandatory | Size, in bytes, of ping packet to be sent out. If set to 0, the default size for ping packet under the protocol chosen will be used. If value given is to too l… |
| 1.3.6.1.4.1.43.29.4.22.1.1.9 | Columna3ComPollSourceAddress | read-write | mandatory | This DisplayString is the network address of the local interface to receive ping query. Typically this is an IP, IPX or AppleTalk. The following formats can be… |
| 1.3.6.1.4.1.43.29.4.22.1.1.10 | Columna3ComPollMinRoundTripTime | read-only | mandatory | The minimum amount of time taken, in msecs, for the round trip of a ping packet. |
| 1.3.6.1.4.1.43.29.4.22.1.1.11 | Columna3ComPollAvgRoundTripTime | read-only | mandatory | The average amount of time taken, in msecs, for the round trip of a ping packet. |
| 1.3.6.1.4.1.43.29.4.22.1.1.12 | Columna3ComPollMaxRoundTripTime | read-only | mandatory | The maximum amount of time taken, in msecs, for the round trip of a ping packet. |
| 1.3.6.1.4.1.43.29.4.22.1.1.13 | Columna3ComPollFramesSent | read-only | mandatory | The number of ping packets sent to remote device so far. |
| 1.3.6.1.4.1.43.29.4.22.1.1.14 | Columna3ComPollFramesReceived | read-only | mandatory | The number of ping packets responded by remote device so far. If a3ComPollResponseTimeOut is a non-zero value, and the poll response arrives after the specifie… |
| 1.3.6.1.4.1.43.29.4.22.1.1.15 | Columna3ComPollInformation | read-only | mandatory | Depending on the protocol being used, this object contains extra information obtained through the device poll. For IP, the value is the number of packets that … |
| 1.3.6.1.4.1.43.29.4.22.1.1.16 | Columna3ComPollOwner | read-write | mandatory | The RMON OwnerString conventions are used here to help control the multi-manager situations. |
| 1.3.6.1.4.1.43.29.4.22.1.1.17 | Columna3ComPollReport | read-only | mandatory | This integer contains the current status of the poll entry. When the state changes from busy to any other, the entry is no longer active. In situations where t… |
| 1.3.6.1.4.1.43.29.4.22.1.1.18 | Columna3ComPollAction | read-write | mandatory | This object is the trigger for initiating, stopping, resetting and destroying a poll entry. In order to read the current status of an entry, a3ComPollReport is… |
| 1.3.6.1.4.1.43.29.4.22.2 | Scalara3ComPollNextFreeIndex | read-only | mandatory | The index for the next available remote polling entry in the table. |
| 1.3.6.1.4.1.43.29.4.22.3 | Scalara3ComPollTableInformation | read-only | mandatory | This object provides a summary on the entire poll table. Internal thresholds, such as the maximum number of entries, as well the number of entries that can be … |
| 1.3.6.1.4.1.43.29.4.22.4 | Scalara3ComPollTableActionAll | read-write | mandatory | This object works exactly as a3ComPollAction, except that it affects every entry in the table, in one snmp transaction. If a3ComPollTableActionAll is called wi… |
| 1.3.6.1.4.1.43.29.4.61 | Nodea3ComPollResponseReceived | This trap is generated when the PollTable in the managed agent receives replies to a poll after a sequence of unsuccessful polls. The number of packets in such… | ||
| 1.3.6.1.4.1.43.29.4.62 | Nodea3ComPollResponseNotReceived | This trap is generated when the PollTable in the managed agent receives no replies to a poll after a sequence of successful polls. The number of packets in suc… |