MIB Viewer

AC-ANALOG-MIB

108 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5003.9.10.8IdentityacAnalog
1.3.6.1.4.1.5003.9.10.8.1NodeacAnalogConfiguration
1.3.6.1.4.1.5003.9.10.8.1.1NodeacAnalogConfig
1.3.6.1.4.1.5003.9.10.8.1.1.1NodeacAnalogMisc
1.3.6.1.4.1.5003.9.10.8.1.1.1.1ScalaracAnalogMiscCurrentDisconnectDurationread-writecurrentDefines the current-disconnect duration (in msec). This value is used in generation and detection. Access: Offline. AC INI-Param: CurrentDisconnectDuration
1.3.6.1.4.1.5003.9.10.8.1.1.1.2ScalaracAnalogMiscFlashHookPeriodread-writecurrentDefines the flashhook period (in msec) for both analog and IP sides. For the analog side it defines: - The maximal hook-flash detection period (for FXS gateway…
1.3.6.1.4.1.5003.9.10.8.1.1.1.3ScalaracAnalogMiscGroundKeyDetectionread-writecurrentEnables/disables the analog ground key detection. 0 = Disable 1= Enable. Access: Offline. AC INI-Param: GroundKeyDetection
1.3.6.1.4.1.5003.9.10.8.1.1.2NodeacAuxiliaryFiles
1.3.6.1.4.1.5003.9.10.8.1.1.2.1ScalaracAuxiliaryFilesFxsCoefficientsread-onlycurrentDefines the FXS loop coefficient filename. Max. 47 characters. AC INI-Param: FXSCOEFFILENAME
1.3.6.1.4.1.5003.9.10.8.1.1.2.2ScalaracAuxiliaryFilesFxoCoefficientsread-onlycurrentDefines the FXO loop coefficient filename. Max. 47 characters. AC INI-Param: FXOCOEFFILENAME
1.3.6.1.4.1.5003.9.10.8.1.2NodeacAnalogFxoConfig
1.3.6.1.4.1.5003.9.10.8.1.2.1NodeacAnalogFxo
1.3.6.1.4.1.5003.9.10.8.1.2.1.1ScalaracAnalogFxoFarEndDisconnectTyperead-writecurrentThis parameter sets the source for the acEV_FAR_END_DISCONNECTED event (or for the relevant control protocol event). It is a bit field parameter, hence (for ex…
1.3.6.1.4.1.5003.9.10.8.1.2.1.2ScalaracAnalogFxoCountryCoefficientsread-writecurrentAllows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: CountryCoefficients
1.3.6.1.4.1.5003.9.10.8.1.2.1.3ScalaracAnalogFxoDCRemoverread-writecurrentDetermines whether to enable the analog DC remover in the DAA. One of the following values: 0 = DC remover is disabled 1 = DC remover is enabled. Access: Offli…
1.3.6.1.4.1.5003.9.10.8.1.2.1.4ScalaracAnalogFxoDefaultLinePolarityStateread-writecurrentSets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts. Access: Offline. AC INI-Param: SetDef…
1.3.6.1.4.1.5003.9.10.8.1.2.1.5ScalaracAnalogFxoTxGainControlread-writecurrentSets gain\attenuation of the FXO Tx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXOTxGainControl
1.3.6.1.4.1.5003.9.10.8.1.2.1.6ScalaracAnalogFxoRxGainControlread-writecurrentSets gain\attenuation of the FXO Rx path between -15db and 12db. default no gain. Access: Offline. AC INI-Param: FXORxGainControl
1.3.6.1.4.1.5003.9.10.8.1.2.1.21TableacAnalogFxoFarEndDisconnectToneTablenot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1RowacAnalogFxoFarEndDisconnectToneEntrynot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.1ColumnacAnalogFxoFarEndDisconnectToneRowStatusread-writecurrentFar End Disconnect table row-status. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.2ColumnacAnalogFxoFarEndDisconnectToneActionread-writecurrentFar End Disconnect table action. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.3ColumnacAnalogFxoFarEndDisconnectToneActionResultread-onlycurrentFar End Disconnect table result. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.4ColumnacAnalogFxoFarEndDisconnectToneIndexread-onlycurrentIndex for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.5ColumnacAnalogFxoFarEndDisconnectToneTyperead-writecurrentDefines which CPT types are detected as far-end disconnect. The CPT type is based on the acTCallProgressToneType enum. This is valid when FarEndDisconnectType …
1.3.6.1.4.1.5003.9.10.8.1.3NodeacAnalogFxsConfig
1.3.6.1.4.1.5003.9.10.8.1.3.1NodeacAnalogFxs
1.3.6.1.4.1.5003.9.10.8.1.3.1.1ScalaracAnalogFxsPolarityReversalTyperead-writecurrentSets the type of the polarity reversal signal used for the network far-end answer and disconnect indications. Smooth reversal prevents negative effects as non-…
1.3.6.1.4.1.5003.9.10.8.1.3.1.2ScalaracAnalogFxsMeteringTyperead-writecurrentSets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-P…
1.3.6.1.4.1.5003.9.10.8.1.3.1.3ScalaracAnalogFxsLifeLineTyperead-writecurrentDefines the Lifeline phone type. The Lifeline phone is available (for FXS only) on port 4 in MP-104 and MP-108, on port 2 in MP-102, on ports 1-4 in the MP-118…
1.3.6.1.4.1.5003.9.10.8.1.3.1.4ScalaracAnalogFxsMinFlashHookTimeread-writecurrentSets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is g…
1.3.6.1.4.1.5003.9.10.8.1.3.1.5ScalaracAnalogFxsCallerIDTimingModeread-writecurrentDefines the Analog CallerID Timing Mode. 0 = CallerID transferred between first and second rings 1 = CallerID transferred on valid Off ring. Access: Offline. A…
1.3.6.1.4.1.5003.9.10.8.1.3.1.6ScalaracAnalogFxsBellcoreCallerIDTypeOneSubStandardread-writecurrentSelects the sub-standard of the Bellcore Caller ID type. 0 = Between_Rings 1 = Not_Ring_Related 2 = Before_Ring_RP_AS. Access: Offline. AC INI-Param: BellcoreC…
1.3.6.1.4.1.5003.9.10.8.1.3.1.7ScalaracAnalogFxsETSICallerIDTypeOneSubStandardread-writecurrentSelects the number denoting the ETSI CallerID Type 1 sub-standard. Either: 0 = ETSI_Between_Rings 1 = ETSI_Before_Ring_DT_AS 2 = ETSI_Before_Ring_RP_AS 3 = ETS…
1.3.6.1.4.1.5003.9.10.8.1.3.1.8ScalaracAnalogFxsETSIVMWITypeOneStandardread-writecurrentSelects the number denoting the ETSI VMWI Type 1 Standard. Choose: 0 = ETSI_VMWI_Between_Rings 1 = ETSI_VMWI_Before_Ring_DT_AS 2 = ETSI_VMWI_Before_Ring_RP_AS …
1.3.6.1.4.1.5003.9.10.8.1.3.1.9ScalaracAnalogFxsBellcoreVMWITypeOneStandardread-writecurrentUse this parameter to select the Bellcore VMWI standard. 0 - Between_Rings 1 - Not_Ring_Related. Access: Offline. AC INI-Param: BellcoreVMWITypeOneStandard
1.3.6.1.4.1.5003.9.10.8.1.3.1.10ScalaracAnalogFxsDisableAutoCalibrationread-writecurrentDetermines whether to enable the analog Autocalibration in the DAA. One of the following values: 0 = Auto calibration is enabled 1 = Auto calibration is disabl…
1.3.6.1.4.1.5003.9.10.8.1.3.1.11ScalaracAnalogFxsExternalLifeLinePortsread-writecurrentSet the amount of FXS ports which will be connected to an external life line and will be disabled (max value is half of the FXS ports). Access: Offline. AC INI…
1.3.6.1.4.1.5003.9.10.8.1.3.1.12ScalaracAnalogFxsCountryCoefficientsread-writecurrentAllows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: FXSCountryCoefficients
1.3.6.1.4.1.5003.9.10.8.1.3.1.13ScalaracAnalogFxsTTXVoltageLevelread-writecurrentSets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts -1 = notAvailable. Access: Offline. AC…
1.3.6.1.4.1.5003.9.10.8.1.4NodeacAnalogEMConfig
1.3.6.1.4.1.5003.9.10.8.1.4.1NodeacAnalogEM
1.3.6.1.4.1.5003.9.10.8.1.4.1.1ScalaracAnalogEMVoiceTyperead-writecurrentE&M Voice Configuration Type 2 or 4 wire. Access: Offline. AC INI-Param: EnMVoiceType
1.3.6.1.4.1.5003.9.10.8.1.4.1.2ScalaracAnalogEMInterfaceTyperead-writecurrentE&M Signaling Type - Trunking or Signaling. Access: Offline. AC INI-Param: EnMSystemType
1.3.6.1.4.1.5003.9.10.8.1.4.1.3ScalaracAnalogEMSignalingTyperead-writecurrentSet E&M standatd signaling types are described in TIA/EIA-464C. Access: Offline. AC INI-Param: EnMSignalingType
1.3.6.1.4.1.5003.9.10.8.1.4.1.4ScalaracAnalogEMPortRXGainread-writecurrentRx Gain. Access: Offline. AC INI-Param: EnMPortRXGain
1.3.6.1.4.1.5003.9.10.8.1.4.1.5ScalaracAnalogEMPortTXGainread-writecurrentTx Gain. Access: Offline. AC INI-Param: EnMPortTXGain
1.3.6.1.4.1.5003.9.10.8.1.4.1.6ScalaracAnalogEMCountryCoefficientsread-writecurrentE&M Country Coefficients. Access: Offline. AC INI-Param: EnMCountryCoefficients
1.3.6.1.4.1.5003.9.10.8.1.4.1.7ScalaracAnalogEMHookDebounceTimingread-writecurrentSets the on E&M hook detection debounce timing. Access: Offline. AC INI-Param: EnMhookDebounceTiming
1.3.6.1.4.1.5003.9.10.8.1.4.1.8ScalaracAnalogEMOffHookGlareEnableread-writecurrentProtect the EnM port from Rx and Tx hook collision. Access: Offline. AC INI-Param: EnMOffHookGlareEnable
1.3.6.1.4.1.5003.9.10.8.2NodeacAnalogStatus
1.3.6.1.4.1.5003.9.10.8.2.1NodeacAnalogStatusMisc
1.3.6.1.4.1.5003.9.10.8.2.1.1ScalaracAnalogStatusMiscFxsOrFxoread-onlycurrentBoard is Fxs,Fxo, FXS_FXO or E&M. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.1.2ScalaracAnalogStatusMiscBoardTemperatureread-onlycurrentTemperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.1.3ScalaracAnalogStatusMiscAnalogChannelsCountread-onlycurrentNumber of the Analog channels in the board. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20NodeacAnalogFxsFxo
1.3.6.1.4.1.5003.9.10.8.2.20.1TableacAnalogFxsFxoTablenot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.2.20.1.1RowacAnalogFxsFxoEntrynot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.1ColumnacAnalogFxsFxoIndexnot-accessiblecurrentIndex for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.2ColumnacAnalogFxsFxoTyperead-onlycurrentLine is Fxs, Fxo or E&M. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.3ColumnacAnalogFxsFxoChipRevNumread-onlycurrentFxs/Fxo's Chip revision number. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.20.1.1.4ColumnacAnalogFxsFxoHookStateread-onlycurrentThe hook state of the analog line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21NodeacAnalogLegs
1.3.6.1.4.1.5003.9.10.8.2.21.1TableacAnalogLegsTablenot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.2.21.1.1RowacAnalogLegsEntrynot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.1ColumnacAnalogLegsLegIndexnot-accessiblecurrentDecribes The Digital EndPoint In A Call. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.2ColumnacAnalogLegsCallIndexread-onlycurrentDecribes The Call which The Rtp EndPoint Participant In It. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.3ColumnacAnalogLegsAnalogTyperead-onlycurrentDescribs whether the board is FXS or FXO. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.4ColumnacAnalogLegsEchoCancellerread-onlycurrentEnables or Disables the Echo Canceller. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.5ColumnacAnalogLegsHighPassFilterread-onlycurrentEnables or Disables theHigh Pass Filter. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.6ColumnacAnalogLegsDTMFDetectionread-onlycurrentEnables or Disables the DTMF Detection. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.7ColumnacAnalogLegsVoiceVolumeread-onlycurrentDescribs the volume of the voice in dB. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.8ColumnacAnalogLegsInputGainread-onlycurrentDescribes the Input Gain on the leg in dB. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.2.21.1.1.9ColumnacAnalogLegsLegNameread-onlycurrentDescribes the Leg Name as in the Control Protocol. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3NodeacAnalogAction
1.3.6.1.4.1.5003.9.10.8.3.1NodeacAnalogFxoAction
1.3.6.1.4.1.5003.9.10.8.3.1.1TableacAnalogFxoLineTestTablenot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.3.1.1.1RowacAnalogFxoLineTestEntrynot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.1ColumnacAnalogFxoLineTestIndexnot-accessiblecurrentIndex for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.2ColumnacAnalogFxoLineTestActivateread-writecurrentActivate line testing in an FXO analog line according to a given line-index. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.3ColumnacAnalogFxoLineTestHookStateread-onlycurrentThe hook state of the analog line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.4ColumnacAnalogFxoLineTestPolarityStatusread-onlycurrentThe line's polarity state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.5ColumnacAnalogFxoLineTestLineConnectionStatusread-onlycurrentThe connection's status of the line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.6ColumnacAnalogFxoLineTestLineCurrentread-onlycurrentThe line's current [ma]. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.7ColumnacAnalogFxoLineTestLineVoltageread-onlycurrentThe line's voltage [V]. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.8ColumnacAnalogFxoLineTestRingStateread-onlycurrentThe Ring's State. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.9ColumnacAnalogFxoLineTestLinePolarityread-onlycurrentThe line's polarity state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.10ColumnacAnalogFxoLineTestMwiStateread-onlycurrentMwi's state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.1.1.1.11ColumnacAnalogFxoLineTestLastCurrentDisconnectDurationread-onlycurrentLast current disconnect duration in msec. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2NodeacAnalogFxsAction
1.3.6.1.4.1.5003.9.10.8.3.2.1TableacAnalogFxsLineTestTablenot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.3.2.1.1RowacAnalogFxsLineTestEntrynot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.1ColumnacAnalogFxsLineTestIndexnot-accessiblecurrentIndex for table use. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.2ColumnacAnalogFxsLineTestActivateread-writecurrentActivate line testing in a FXS analog line according to a given line-index. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.3ColumnacAnalogFxsLineTestHookStateread-onlycurrentThe hook state of the analog line. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.4ColumnacAnalogFxsLineTestRingStateread-onlycurrentLine's ring state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.5ColumnacAnalogFxsLineTestPolarityStatusread-onlycurrentLine's reversal-polarity. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.6ColumnacAnalogFxsLineTestMessageWaitingIndicationread-onlycurrentLine's messgae waiting indication state. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.7ColumnacAnalogFxsLineTestLineCurrentReadingread-onlyobsoleteThe Line current reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports…
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.8ColumnacAnalogFxsLineTestLineVoltageReadingread-onlyobsoleteThe Line voltage reading in 10mV units. In case of MP124 the Line voltage reading in 1V units. This test is supported only in line no. 0. Not supported on MP50…
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.9ColumnacAnalogFxsLineTestAnalogVoltageReadingread-onlyobsoleteThe current analog voltage reading in 10mV units. his test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in …
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.10ColumnacAnalogFxsLineTestRingVoltageReadingread-onlyobsoleteThe current ring voltage reading in 10mV units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in a…
1.3.6.1.4.1.5003.9.10.8.3.2.1.1.11ColumnacAnalogFxsLineTestLongLineCurrentReadingread-onlyobsoleteThe current long line reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all …
1.3.6.1.4.1.5003.9.10.8.3.3NodeacAnalogCommonAction
1.3.6.1.4.1.5003.9.10.8.3.3.1TableacAnalogCommonChannelTablenot-accessiblecurrentTable for common channels operations.
1.3.6.1.4.1.5003.9.10.8.3.3.1.1RowacAnalogCommonChannelEntrynot-accessiblecurrent
1.3.6.1.4.1.5003.9.10.8.3.3.1.1.1ColumnacAnalogCommonChannelIndexnot-accessiblecurrentIndex for table use, the current channel. AC INI-Param: N/A
1.3.6.1.4.1.5003.9.10.8.3.3.1.1.2ColumnacAnalogCommonChannelActionread-writecurrentAn action to make on the current channel, The Reset action is for Analog channels only. AC INI-Param: N/A