ACD-DESC-MIB
47 objects
The Accedian Networks device Description MIB.
Imported Objects
| ACCEDIAN-SMI | acdProducts |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-MIB | sysName |
| SNMPv2-SMI | Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString MacAddress TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.22420.1.1 | IdentityacdDesc | The Accedian Networks device Description MIB. | ||
| 1.3.6.1.4.1.22420.1.1.0 | NodeacdDescNotifications | |||
| 1.3.6.1.4.1.22420.1.1.0.1 | NotificationacdPowerLost | current | The SNMP trap that is generated by a unit when it detect a power lost. It's the equivalent of the 802.3ah dying gasp. | |
| 1.3.6.1.4.1.22420.1.1.1 | ScalaracdDescCommercialName | read-only | current | This string is to describe the type of device. |
| 1.3.6.1.4.1.22420.1.1.2 | ScalaracdDescMacBaseAddr | read-only | current | This is the Base of the EtherNID MAC addresses. |
| 1.3.6.1.4.1.22420.1.1.3 | ScalaracdDescIdentifier | read-only | current | Identifies the EtherNID on your network. |
| 1.3.6.1.4.1.22420.1.1.4 | ScalaracdDescFirmwareVersion | read-only | current | Indicates the version of the firmware currently loaded. |
| 1.3.6.1.4.1.22420.1.1.5 | ScalaracdDescHardwareVersion | read-only | current | Indicates the assembly ID of the hardware. |
| 1.3.6.1.4.1.22420.1.1.6 | ScalaracdDescSerialNumber | read-only | current | Indicates the serial number. |
| 1.3.6.1.4.1.22420.1.1.7 | ScalaracdDescHardwareOptions | read-only | current | Indicates the Hardware options. |
| 1.3.6.1.4.1.22420.1.1.10 | TableacdDescConnectorTable | not-accessible | current | Table of all connectors info |
| 1.3.6.1.4.1.22420.1.1.10.1 | RowacdDescConnectorEntry | not-accessible | current | This is the product connector definition. |
| 1.3.6.1.4.1.22420.1.1.10.1.1 | ColumnacdDescConnectorID | not-accessible | current | Unique value for each connector. Starting to one from left to right. |
| 1.3.6.1.4.1.22420.1.1.10.1.2 | ColumnacdDescConnectorName | read-only | current | Identifies the connector on the silkscreen. |
| 1.3.6.1.4.1.22420.1.1.10.1.3 | ColumnacdDescConnectorType | read-only | current | Describe the connector type, for instance an RJ-45 or an SFP. |
| 1.3.6.1.4.1.22420.1.1.10.1.4 | ColumnacdDescConnectorPoESupport | read-only | current | This is to indicate if the port support PoE or not. |
| 1.3.6.1.4.1.22420.1.1.11 | TableacdDescPwrTable | not-accessible | current | Table of all Power Supplies |
| 1.3.6.1.4.1.22420.1.1.11.1 | RowacdDescPwrEntry | not-accessible | current | This is the product available power supplies information. |
| 1.3.6.1.4.1.22420.1.1.11.1.1 | ColumnacdDescPwrID | not-accessible | current | Unique value for each power supply. |
| 1.3.6.1.4.1.22420.1.1.11.1.2 | ColumnacdDescPwrName | read-only | current | Identifies the power supply. |
| 1.3.6.1.4.1.22420.1.1.11.1.3 | ColumnacdDescPwrType | read-only | current | Describe the Power Supply type. |
| 1.3.6.1.4.1.22420.1.1.11.1.4 | ColumnacdDescPwrPresent | read-only | current | This is to indicate if the power supply is present or not. |
| 1.3.6.1.4.1.22420.1.1.12 | TableacdDescTsTable | not-accessible | current | Table of all Teperature Sensors. |
| 1.3.6.1.4.1.22420.1.1.12.1 | RowacdDescTsEntry | not-accessible | current | This is the product available Temperature sensor information. |
| 1.3.6.1.4.1.22420.1.1.12.1.1 | ColumnacdDescTsID | not-accessible | current | Unique value for each Temperature Sensor. |
| 1.3.6.1.4.1.22420.1.1.12.1.2 | ColumnacdDescTsCurrentTemp | read-only | current | Current temperature in Celsius around the temperature sensor. On LT and LT-S units this value is truncated and does not include the decimals. |
| 1.3.6.1.4.1.22420.1.1.12.1.3 | ColumnacdDescTsFirstThres | read-only | current | Temperature value in Celsius to declare this threshold crossed. On LT and LT-S units this value is truncated and does not include the decimals. |
| 1.3.6.1.4.1.22420.1.1.12.1.4 | ColumnacdDescTsFisrtThresPass | read-only | current | This is to indicate if the temperature cross the first threshold. |
| 1.3.6.1.4.1.22420.1.1.12.1.5 | ColumnacdDescTsSecondThres | read-only | current | Temperature value in Celsius to declare this second threshold crossed. On LT and LT-S units this value is truncated and does not include the decimals. |
| 1.3.6.1.4.1.22420.1.1.12.1.6 | ColumnacdDescTsSecondThresPass | read-only | current | This is to indicate if the temperature cross the second threshold. |
| 1.3.6.1.4.1.22420.1.1.12.1.7 | ColumnacdDescTsLabel | read-only | current | Label of the temperature sensor. |
| 1.3.6.1.4.1.22420.1.1.15 | NodeacdDescMIBObjects | |||
| 1.3.6.1.4.1.22420.1.1.15.1 | NodeacdDescConformance | |||
| 1.3.6.1.4.1.22420.1.1.15.1.1 | NodeacdDescCompliances | |||
| 1.3.6.1.4.1.22420.1.1.15.1.1.1 | ComplianceacdDescCompliance | current | The compliance statement for support of the ACD-DESC-MIB module. | |
| 1.3.6.1.4.1.22420.1.1.15.1.2 | NodeacdDescGroups | |||
| 1.3.6.1.4.1.22420.1.1.15.1.2.1 | GroupacdDescGenGroup | current | . | |
| 1.3.6.1.4.1.22420.1.1.15.1.2.2 | GroupacdDescConnectorGroup | current | . | |
| 1.3.6.1.4.1.22420.1.1.15.1.2.3 | GroupacdDescPwrGroup | current | . | |
| 1.3.6.1.4.1.22420.1.1.15.1.2.4 | GroupacdDescTsGroup | current | . | |
| 1.3.6.1.4.1.22420.1.1.15.1.2.5 | GroupacdDescNotificationsGroup | current | Objects for the Notifications group. | |
| 1.3.6.1.4.1.22420.1.1.20 | ScalaracdDescCpuUsageCurrent | read-only | current | Indicates the current percentage of CPU usage. |
| 1.3.6.1.4.1.22420.1.1.21 | ScalaracdDescCpuUsageAverage15 | read-only | current | Indicates the average percentage of CPU usage over the last 15 seconds. This object range from (0..100). |
| 1.3.6.1.4.1.22420.1.1.22 | ScalaracdDescCpuUsageAverage30 | read-only | current | Indicates the average percentage of CPU usage over the last 30 seconds. This object range from (0..100). |
| 1.3.6.1.4.1.22420.1.1.23 | ScalaracdDescCpuUsageAverage60 | read-only | current | Indicates the average percentage of CPU usage over the last 60 seconds. This object range from (0..100). |
| 1.3.6.1.4.1.22420.1.1.24 | ScalaracdDescCpuUsageAverage900 | read-only | current | Indicates the average percentage of CPU usage over the last 900 seconds. This object range from (0..100). |
| 1.3.6.1.4.1.22420.1.1.25 | ScalaracdDescUptime | read-only | current | Number of seconds elapsed since boot. |