MIB Viewer

ACD-DESC-MIB

47 objects
The Accedian Networks device Description MIB.
Imported Objects
ACCEDIAN-SMIacdProducts
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-MIBsysName
SNMPv2-SMIGauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.22420.1.1IdentityacdDescThe Accedian Networks device Description MIB.
1.3.6.1.4.1.22420.1.1.0NodeacdDescNotifications
1.3.6.1.4.1.22420.1.1.0.1NotificationacdPowerLostcurrentThe SNMP trap that is generated by a unit when it detect a power lost. It's the equivalent of the 802.3ah dying gasp.
1.3.6.1.4.1.22420.1.1.1ScalaracdDescCommercialNameread-onlycurrentThis string is to describe the type of device.
1.3.6.1.4.1.22420.1.1.2ScalaracdDescMacBaseAddrread-onlycurrentThis is the Base of the EtherNID MAC addresses.
1.3.6.1.4.1.22420.1.1.3ScalaracdDescIdentifierread-onlycurrentIdentifies the EtherNID on your network.
1.3.6.1.4.1.22420.1.1.4ScalaracdDescFirmwareVersionread-onlycurrentIndicates the version of the firmware currently loaded.
1.3.6.1.4.1.22420.1.1.5ScalaracdDescHardwareVersionread-onlycurrentIndicates the assembly ID of the hardware.
1.3.6.1.4.1.22420.1.1.6ScalaracdDescSerialNumberread-onlycurrentIndicates the serial number.
1.3.6.1.4.1.22420.1.1.7ScalaracdDescHardwareOptionsread-onlycurrentIndicates the Hardware options.
1.3.6.1.4.1.22420.1.1.10TableacdDescConnectorTablenot-accessiblecurrentTable of all connectors info
1.3.6.1.4.1.22420.1.1.10.1RowacdDescConnectorEntrynot-accessiblecurrentThis is the product connector definition.
1.3.6.1.4.1.22420.1.1.10.1.1ColumnacdDescConnectorIDnot-accessiblecurrentUnique value for each connector. Starting to one from left to right.
1.3.6.1.4.1.22420.1.1.10.1.2ColumnacdDescConnectorNameread-onlycurrentIdentifies the connector on the silkscreen.
1.3.6.1.4.1.22420.1.1.10.1.3ColumnacdDescConnectorTyperead-onlycurrentDescribe the connector type, for instance an RJ-45 or an SFP.
1.3.6.1.4.1.22420.1.1.10.1.4ColumnacdDescConnectorPoESupportread-onlycurrentThis is to indicate if the port support PoE or not.
1.3.6.1.4.1.22420.1.1.11TableacdDescPwrTablenot-accessiblecurrentTable of all Power Supplies
1.3.6.1.4.1.22420.1.1.11.1RowacdDescPwrEntrynot-accessiblecurrentThis is the product available power supplies information.
1.3.6.1.4.1.22420.1.1.11.1.1ColumnacdDescPwrIDnot-accessiblecurrentUnique value for each power supply.
1.3.6.1.4.1.22420.1.1.11.1.2ColumnacdDescPwrNameread-onlycurrentIdentifies the power supply.
1.3.6.1.4.1.22420.1.1.11.1.3ColumnacdDescPwrTyperead-onlycurrentDescribe the Power Supply type.
1.3.6.1.4.1.22420.1.1.11.1.4ColumnacdDescPwrPresentread-onlycurrentThis is to indicate if the power supply is present or not.
1.3.6.1.4.1.22420.1.1.12TableacdDescTsTablenot-accessiblecurrentTable of all Teperature Sensors.
1.3.6.1.4.1.22420.1.1.12.1RowacdDescTsEntrynot-accessiblecurrentThis is the product available Temperature sensor information.
1.3.6.1.4.1.22420.1.1.12.1.1ColumnacdDescTsIDnot-accessiblecurrentUnique value for each Temperature Sensor.
1.3.6.1.4.1.22420.1.1.12.1.2ColumnacdDescTsCurrentTempread-onlycurrentCurrent temperature in Celsius around the temperature sensor. On LT and LT-S units this value is truncated and does not include the decimals.
1.3.6.1.4.1.22420.1.1.12.1.3ColumnacdDescTsFirstThresread-onlycurrentTemperature value in Celsius to declare this threshold crossed. On LT and LT-S units this value is truncated and does not include the decimals.
1.3.6.1.4.1.22420.1.1.12.1.4ColumnacdDescTsFisrtThresPassread-onlycurrentThis is to indicate if the temperature cross the first threshold.
1.3.6.1.4.1.22420.1.1.12.1.5ColumnacdDescTsSecondThresread-onlycurrentTemperature value in Celsius to declare this second threshold crossed. On LT and LT-S units this value is truncated and does not include the decimals.
1.3.6.1.4.1.22420.1.1.12.1.6ColumnacdDescTsSecondThresPassread-onlycurrentThis is to indicate if the temperature cross the second threshold.
1.3.6.1.4.1.22420.1.1.12.1.7ColumnacdDescTsLabelread-onlycurrentLabel of the temperature sensor.
1.3.6.1.4.1.22420.1.1.15NodeacdDescMIBObjects
1.3.6.1.4.1.22420.1.1.15.1NodeacdDescConformance
1.3.6.1.4.1.22420.1.1.15.1.1NodeacdDescCompliances
1.3.6.1.4.1.22420.1.1.15.1.1.1ComplianceacdDescCompliancecurrentThe compliance statement for support of the ACD-DESC-MIB module.
1.3.6.1.4.1.22420.1.1.15.1.2NodeacdDescGroups
1.3.6.1.4.1.22420.1.1.15.1.2.1GroupacdDescGenGroupcurrent.
1.3.6.1.4.1.22420.1.1.15.1.2.2GroupacdDescConnectorGroupcurrent.
1.3.6.1.4.1.22420.1.1.15.1.2.3GroupacdDescPwrGroupcurrent.
1.3.6.1.4.1.22420.1.1.15.1.2.4GroupacdDescTsGroupcurrent.
1.3.6.1.4.1.22420.1.1.15.1.2.5GroupacdDescNotificationsGroupcurrentObjects for the Notifications group.
1.3.6.1.4.1.22420.1.1.20ScalaracdDescCpuUsageCurrentread-onlycurrentIndicates the current percentage of CPU usage.
1.3.6.1.4.1.22420.1.1.21ScalaracdDescCpuUsageAverage15read-onlycurrentIndicates the average percentage of CPU usage over the last 15 seconds. This object range from (0..100).
1.3.6.1.4.1.22420.1.1.22ScalaracdDescCpuUsageAverage30read-onlycurrentIndicates the average percentage of CPU usage over the last 30 seconds. This object range from (0..100).
1.3.6.1.4.1.22420.1.1.23ScalaracdDescCpuUsageAverage60read-onlycurrentIndicates the average percentage of CPU usage over the last 60 seconds. This object range from (0..100).
1.3.6.1.4.1.22420.1.1.24ScalaracdDescCpuUsageAverage900read-onlycurrentIndicates the average percentage of CPU usage over the last 900 seconds. This object range from (0..100).
1.3.6.1.4.1.22420.1.1.25ScalaracdDescUptimeread-onlycurrentNumber of seconds elapsed since boot.