MIB Viewer

ACD-SFP-MIB

101 objects
The SFPs database for this Accedian Networks device.
Imported Objects
ACCEDIAN-SMIacdMibs
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.22420.2.4IdentityacdSfpThe SFPs database for this Accedian Networks device.
1.3.6.1.4.1.22420.2.4.1TableacdSfpInfoTablenot-accessiblecurrentTable of all SFP info
1.3.6.1.4.1.22420.2.4.1.1RowacdSfpInfoEntrynot-accessiblecurrentThis is a part of the content of the SFP's 0xA0 EEPROM
1.3.6.1.4.1.22420.2.4.1.1.1ColumnacdSfpInfoIDnot-accessiblecurrentUnique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
1.3.6.1.4.1.22420.2.4.1.1.2ColumnacdSfpInfoConnIdxread-onlycurrentThis object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
1.3.6.1.4.1.22420.2.4.1.1.3ColumnacdSfpInfoConnTyperead-onlycurrentThe connector value indicates the external optical or electrical cable connector provided as the media interface.
1.3.6.1.4.1.22420.2.4.1.1.4ColumnacdSfpInfoVendorread-onlycurrentThe vendor name is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h). The vendor name shall be …
1.3.6.1.4.1.22420.2.4.1.1.5ColumnacdSfpInfoVendorOuiread-onlycurrentThe vendor organizationally unique identifier field (vendor OUI) is a 3-byte field that contains the IEEE Company Identifier for the vendor. A value of all zer…
1.3.6.1.4.1.22420.2.4.1.1.6ColumnacdSfpInfoVendorPnread-onlycurrentThe vendor part number (vendor PN) is a 16-byte field that contains ASCII characters, leftaligned and padded on the right with ASCII spaces (20h), defining the…
1.3.6.1.4.1.22420.2.4.1.1.7ColumnacdSfpInfoVendorRevread-onlycurrentThe vendor revision number (vendor rev) is a 4-byte field that contains ASCII characters, leftaligned and padded on the right with ASCII spaces (20h), defining…
1.3.6.1.4.1.22420.2.4.1.1.8ColumnacdSfpInfoWavelengthread-onlycurrentNominal transmitter output wavelength at room temperature. 16 bit value with byte 60 as high order byte and byte 61 as low order byte. The laser wavelength is …
1.3.6.1.4.1.22420.2.4.1.1.9ColumnacdSfpInfoSerialNumread-onlycurrentThe vendor serial number (vendor SN) is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defi…
1.3.6.1.4.1.22420.2.4.1.1.10ColumnacdSfpInfoYearread-onlycurrentThis is the year of manufacturing.
1.3.6.1.4.1.22420.2.4.1.1.11ColumnacdSfpInfoMonthread-onlycurrentThis is the month of manufacturing.
1.3.6.1.4.1.22420.2.4.1.1.12ColumnacdSfpInfoDayread-onlycurrentThis is the day of manufacturing.
1.3.6.1.4.1.22420.2.4.1.1.13ColumnacdSfpInfoLotread-onlycurrentThis is the Lot number of manufacturing.
1.3.6.1.4.1.22420.2.4.1.1.14ColumnacdSfpInfoRev8472read-onlycurrentThis is to indicate to which revision this SFP is compatible.
1.3.6.1.4.1.22420.2.4.1.1.15ColumnacdSfpInfoPresentread-onlycurrentThis is to indicate if the SFP is present or not.
1.3.6.1.4.1.22420.2.4.1.1.16ColumnacdSfpInfoDiagread-onlycurrentThis is to indicate if the SFP supports Digital Diagnostics.
1.3.6.1.4.1.22420.2.4.1.1.17ColumnacdSfpInfoInternalread-onlycurrentThis is to indicate if the SFP supports internal calibration. If externally calibrated, the measurements are raw A/D values and must be converted to real world…
1.3.6.1.4.1.22420.2.4.1.1.18ColumnacdSfpInfoAlmread-onlycurrentThis is to indicate if the SFP supports Alarm and warning thresholds for the Digital Diagnostics.
1.3.6.1.4.1.22420.2.4.1.1.19ColumnacdSfpInfoIdTyperead-onlycurrentThe identifier value specifies the physical device described by the two-wire interface information. This value shall be included in the two-wire interface data…
1.3.6.1.4.1.22420.2.4.1.1.20ColumnacdSfpInfoExtIdTyperead-onlycurrentThe extended identifier value provides additional information about the transceiver. The field should be set to 04h for all SFP modules indicating two-wire int…
1.3.6.1.4.1.22420.2.4.1.1.21ColumnacdSfpInfoTransCoderead-onlycurrentThe following bit significant indicators define the electronic or optical interfaces that are supported by the transceiver. At least one bit shall be set in th…
1.3.6.1.4.1.22420.2.4.2TableacdSfpDiagTablenot-accessiblecurrentTable of all SFP Digital Diagnostics
1.3.6.1.4.1.22420.2.4.2.1RowacdSfpDiagEntrynot-accessiblecurrentThis is a part the content of the SFP's 0xA0 EEPROM
1.3.6.1.4.1.22420.2.4.2.1.1ColumnacdSfpDiagIDnot-accessiblecurrentUnique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
1.3.6.1.4.1.22420.2.4.2.1.2ColumnacdSfpDiagConnIdxread-onlycurrentThis object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
1.3.6.1.4.1.22420.2.4.2.1.3ColumnacdSfpDiagTempread-onlycurrentInternally measured transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
1.3.6.1.4.1.22420.2.4.2.1.4ColumnacdSfpDiagVccread-onlycurrentInternally measured transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LS…
1.3.6.1.4.1.22420.2.4.2.1.5ColumnacdSfpDiagLbcread-onlycurrentMeasured TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
1.3.6.1.4.1.22420.2.4.2.1.6ColumnacdSfpDiagTxPwrread-onlycurrentMeasured TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 mic…
1.3.6.1.4.1.22420.2.4.2.1.7ColumnacdSfpDiagRxPwrread-onlycurrentMeasured Rx input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 micr…
1.3.6.1.4.1.22420.2.4.2.1.8ColumnacdSfpDiagTxPwrdBmread-onlycurrentMeasured TX output power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.2.1.9ColumnacdSfpDiagRxPwrdBmread-onlycurrentMeasured Rx input power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3TableacdSfpThreshTablenot-accessiblecurrentTable of all SFP Alarm and Warning Thresholds
1.3.6.1.4.1.22420.2.4.3.1RowacdSfpThreshEntrynot-accessiblecurrentThis is a part the content of the SFP's 0xA0 EEPROM
1.3.6.1.4.1.22420.2.4.3.1.1ColumnacdSfpThreshIDnot-accessiblecurrentUnique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
1.3.6.1.4.1.22420.2.4.3.1.2ColumnacdSfpThreshConnIdxread-onlycurrentThis object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
1.3.6.1.4.1.22420.2.4.3.1.3ColumnacdSfpThreshTempHighAlmread-onlycurrentHigh Alarm transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
1.3.6.1.4.1.22420.2.4.3.1.4ColumnacdSfpThreshTempLowAlmread-onlycurrentLow Alarm transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
1.3.6.1.4.1.22420.2.4.3.1.5ColumnacdSfpThreshTempHighWarnread-onlycurrentHigh Warning transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
1.3.6.1.4.1.22420.2.4.3.1.6ColumnacdSfpThreshTempLowWarnread-onlycurrentLow Warning transceiver temperature. Represented as a 16 bit signed twos complement value in degrees Celsius, yielding a total range of -128C to +128C.
1.3.6.1.4.1.22420.2.4.3.1.7ColumnacdSfpThreshVccHighAlmread-onlycurrentHigh Alarm transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal t…
1.3.6.1.4.1.22420.2.4.3.1.8ColumnacdSfpThreshVccLowAlmread-onlycurrentLow Alarm transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal to…
1.3.6.1.4.1.22420.2.4.3.1.9ColumnacdSfpThreshVccHighWarnread-onlycurrentHigh Warning transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal…
1.3.6.1.4.1.22420.2.4.3.1.10ColumnacdSfpThreshVccLowWarnread-onlycurrentLow Warning transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 to 65535) with LSB equal …
1.3.6.1.4.1.22420.2.4.3.1.11ColumnacdSfpThreshLbcHighAlmread-onlycurrentHigh Alarm TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
1.3.6.1.4.1.22420.2.4.3.1.12ColumnacdSfpThreshLbcLowAlmread-onlycurrentLow Alarm TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
1.3.6.1.4.1.22420.2.4.3.1.13ColumnacdSfpThreshLbcHighWarnread-onlycurrentHigh Warning TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
1.3.6.1.4.1.22420.2.4.3.1.14ColumnacdSfpThreshLbcLowWarnread-onlycurrentLow Warning TX bias current in micro-Amps yielding a total range of 0 to 131 mA.
1.3.6.1.4.1.22420.2.4.3.1.15ColumnacdSfpThreshTxPwrHighAlmread-onlycurrentHigh Alarm TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 m…
1.3.6.1.4.1.22420.2.4.3.1.16ColumnacdSfpThreshTxPwrLowAlmread-onlycurrentLow Alarm TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 mi…
1.3.6.1.4.1.22420.2.4.3.1.17ColumnacdSfpThreshTxPwrHighWarnread-onlycurrentHigh Warning TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1…
1.3.6.1.4.1.22420.2.4.3.1.18ColumnacdSfpThreshTxPwrLowWarnread-onlycurrentLow Warning TX output power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 …
1.3.6.1.4.1.22420.2.4.3.1.19ColumnacdSfpThreshRxPwrHighAlmread-onlycurrentHigh Alarm RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 mi…
1.3.6.1.4.1.22420.2.4.3.1.20ColumnacdSfpThreshRxPwrLowAlmread-onlycurrentLow Alarm RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 mic…
1.3.6.1.4.1.22420.2.4.3.1.21ColumnacdSfpThreshRxPwrHighWarnread-onlycurrentHigh Warning RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 …
1.3.6.1.4.1.22420.2.4.3.1.22ColumnacdSfpThreshRxPwrLowWarnread-onlycurrentLow Warning RX input power in mW. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 to 65535) with LSB equal to 0.1 m…
1.3.6.1.4.1.22420.2.4.3.1.23ColumnacdSfpThreshTxPwrHighAlmdBmread-onlycurrentHigh Alarm TX output power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3.1.24ColumnacdSfpThreshTxPwrLowAlmdBmread-onlycurrentLow Alarm TX output power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3.1.25ColumnacdSfpThreshTxPwrHighWarndBmread-onlycurrentHigh Warning TX output power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3.1.26ColumnacdSfpThreshTxPwrLowWarndBmread-onlycurrentLow Warning TX output power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3.1.27ColumnacdSfpThreshRxPwrHighAlmdBmread-onlycurrentHigh Alarm Rx input power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3.1.28ColumnacdSfpThreshRxPwrLowAlmdBmread-onlycurrentLow Alarm Rx input power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3.1.29ColumnacdSfpThreshRxPwrHighWarndBmread-onlycurrentHigh Warning Rx input power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.3.1.30ColumnacdSfpThreshRxPwrLowWarndBmread-onlycurrentLow Warning Rx input power in dBm (~ -40 to +8.2 dBm).
1.3.6.1.4.1.22420.2.4.4TableacdSfpThreshStatusTablenot-accessiblecurrentTable of all SFP Digital Diagnostics Thresholds statuses
1.3.6.1.4.1.22420.2.4.4.1RowacdSfpThreshStatusEntrynot-accessiblecurrentThis is a part the content of the SFP's 0xA2 EEPROM
1.3.6.1.4.1.22420.2.4.4.1.1ColumnacdSfpThreshStatusIDnot-accessiblecurrentUnique value for each SFP. Its value ranges from 1 to MAXINT (4 bytes).
1.3.6.1.4.1.22420.2.4.4.1.2ColumnacdSfpThreshStatusConnIdxread-onlycurrentThis object identifies the connector index on the box. The index is assigned form left to rigth starting with 1.
1.3.6.1.4.1.22420.2.4.4.1.3ColumnacdSfpThreshStatusTempHighAlmread-onlycurrentThis is to indicate if the temperature reaches or overpasses the High alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.4ColumnacdSfpThreshStatusTempLowAlmread-onlycurrentThis is to indicate if the temperature reaches or underpasses the Low alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.5ColumnacdSfpThreshStatusTempHighWarnread-onlycurrentThis is to indicate if the temperature reaches or overpasses the High warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.6ColumnacdSfpThreshStatusTempLowWarnread-onlycurrentThis is to indicate if the temperature reaches or underpasses the Low warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.7ColumnacdSfpThreshStatusVccHighAlmread-onlycurrentThis is to indicate if the supply voltage reaches or overpasses the High alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.8ColumnacdSfpThreshStatusVccLowAlmread-onlycurrentThis is to indicate if the supply voltage reaches or underpasses the Low alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.9ColumnacdSfpThreshStatusVccHighWarnread-onlycurrentThis is to indicate if the supply voltage reaches or overpasses the High warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.10ColumnacdSfpThreshStatusVccLowWarnread-onlycurrentThis is to indicate if the supply voltage reaches or underpasses the Low warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.11ColumnacdSfpThreshStatusLbcHighAlmread-onlycurrentThis is to indicate if the Laser Bias Current reaches or overpasses the High alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.12ColumnacdSfpThreshStatusLbcLowAlmread-onlycurrentThis is to indicate if the Laser Bias Current reaches or underpasses the Low alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.13ColumnacdSfpThreshStatusLbcHighWarnread-onlycurrentThis is to indicate if the Laser Bias Current reaches or overpasses the High warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.14ColumnacdSfpThreshStatusLbcLowWarnread-onlycurrentThis is to indicate if the Laser Bias Current reaches or underpasses the Low warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.15ColumnacdSfpThreshStatusTxPwrHighAlmread-onlycurrentThis is to indicate if the Transmit Power reaches or overpasses the High alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.16ColumnacdSfpThreshStatusTxPwrLowAlmread-onlycurrentThis is to indicate if the Transmit Power reaches or underpasses the Low alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.17ColumnacdSfpThreshStatusTxPwrHighWarnread-onlycurrentThis is to indicate if the Transmit Power reaches or overpasses the High warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.18ColumnacdSfpThreshStatusTxPwrLowWarnread-onlycurrentThis is to indicate if the Transmit Power reaches or underpasses the Low warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.19ColumnacdSfpThreshStatusRxPwrHighAlmread-onlycurrentThis is to indicate if the Receive Power reaches or overpasses the High alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.20ColumnacdSfpThreshStatusRxPwrLowAlmread-onlycurrentThis is to indicate if the Receive Power reaches or underpasses the Low alarm threshold.
1.3.6.1.4.1.22420.2.4.4.1.21ColumnacdSfpThreshStatusRxPwrHighWarnread-onlycurrentThis is to indicate if the Receive Power reaches or overpasses the High warning threshold.
1.3.6.1.4.1.22420.2.4.4.1.22ColumnacdSfpThreshStatusRxPwrLowWarnread-onlycurrentThis is to indicate if the Receive Power reaches or underpasses the Low warning threshold.
1.3.6.1.4.1.22420.2.4.5NodeacdSfpNotifications
1.3.6.1.4.1.22420.2.4.6NodeacdSfpMIBObjects
1.3.6.1.4.1.22420.2.4.7NodeacdSfpConformance
1.3.6.1.4.1.22420.2.4.7.1NodeacdSfpCompliances
1.3.6.1.4.1.22420.2.4.7.1.1ComplianceacdSfpCompliancecurrentThe compliance statement for support of the ACD-SFP-MIB module.
1.3.6.1.4.1.22420.2.4.7.2NodeacdSfpGroups
1.3.6.1.4.1.22420.2.4.7.2.1GroupacdSfpInfoGroupcurrentObjects for the SFP information Group.
1.3.6.1.4.1.22420.2.4.7.2.2GroupacdSfpDiagGroupcurrentObjects for the SFP diagnostics Group.
1.3.6.1.4.1.22420.2.4.7.2.3GroupacdSfpThreshGroupcurrentObjects for the SFP thresholds Group.
1.3.6.1.4.1.22420.2.4.7.2.4GroupacdSfpThreshStatusGroupcurrentObjects for the SFP threshold status Group.