MIB Viewer

ACS8000-MIB

496 objects
This module defines the MIB extensions to ACS80xx products.
Imported Objects
IF-MIBInterfaceIndex InterfaceIndexOrZero
RFC-1215TRAP-TYPE
RFC1155-SMICounter Gauge IpAddress NetworkAddress TimeTicks
RFC1213-MIBPhysAddress
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.10418.26IdentityacsThis module defines the MIB extensions to ACS80xx products.
1.3.6.1.4.1.10418.26.1NodeacsProducts
1.3.6.1.4.1.10418.26.1.1Nodeacs8048
1.3.6.1.4.1.10418.26.1.2Nodeacs8032
1.3.6.1.4.1.10418.26.1.3Nodeacs8016
1.3.6.1.4.1.10418.26.1.4Nodeacs8008
1.3.6.1.4.1.10418.26.1.5Nodeacs808
1.3.6.1.4.1.10418.26.1.6Nodeacs804
1.3.6.1.4.1.10418.26.1.7Nodeacs802
1.3.6.1.4.1.10418.26.2NodeacsManagement
1.3.6.1.4.1.10418.26.2.1NodeacsAppliance
1.3.6.1.4.1.10418.26.2.1.1ScalaracsHostNameread-onlycurrentThe appliance name
1.3.6.1.4.1.10418.26.2.1.2ScalaracsProductModelread-onlycurrentThe appliance product model
1.3.6.1.4.1.10418.26.2.1.3ScalaracsPartNumberread-onlycurrentThe part number of this appliance as shown on the label attached or imprinted on the appliance.
1.3.6.1.4.1.10418.26.2.1.4ScalaracsSerialNumberread-onlycurrentThe serial number of this appliance as shown on the label attached or imprinted on the appliance.
1.3.6.1.4.1.10418.26.2.1.5ScalaracsEIDNumberread-onlycurrentThe electronic ID number (EID) of this appliance as shown on the label attached or imprinted on the appliance.
1.3.6.1.4.1.10418.26.2.1.6ScalaracsBootcodeVersionread-onlycurrentThe version of the bootcode of this appliance.
1.3.6.1.4.1.10418.26.2.1.7ScalaracsFirmwareVersionread-onlycurrentThe version of the firmware of this appliance.
1.3.6.1.4.1.10418.26.2.1.8IdentityacsPowerSupplycurrentIt gives information about Power Supply of this appliance
1.3.6.1.4.1.10418.26.2.1.8.1ScalaracsPowerSupplyNumberread-onlycurrentNumber of the power supplies of this appliance
1.3.6.1.4.1.10418.26.2.1.8.2ScalaracsPowerSupplyStatePw1read-onlycurrentState of the first power supply
1.3.6.1.4.1.10418.26.2.1.8.3ScalaracsPowerSupplyStatePw2read-onlycurrentState of the second power supply
1.3.6.1.4.1.10418.26.2.1.9ScalaracsRebootread-writecurrentA set value of reboot(2) will reboot the appliance. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the appliance immediately…
1.3.6.1.4.1.10418.26.2.1.10TableacsScheduledTasksTablenot-accessiblecurrentThis table contains the list of the scheduled tasks.
1.3.6.1.4.1.10418.26.2.1.10.1RowacsScheduledTasksTableEntrynot-accessiblecurrenteach entry has the information about the scheduled task
1.3.6.1.4.1.10418.26.2.1.10.1.1ColumnacsScheduledTasksTableIndexread-onlycurrentA unique index representing an entry in this table.
1.3.6.1.4.1.10418.26.2.1.10.1.2ColumnacsScheduledTasksTableTyperead-onlycurrentThe type of the scheduled task.
1.3.6.1.4.1.10418.26.2.1.10.1.3ColumnacsScheduledTasksTableNameread-onlycurrentName of the scheduled task.
1.3.6.1.4.1.10418.26.2.1.10.1.4ColumnacsScheduledTasksTableStatusread-writecurrentWhen set to enabled, the task will be run according to the schedule defined by acsScheduledTasksTableFrequency.
1.3.6.1.4.1.10418.26.2.1.10.1.5ColumnacsScheduledTasksTableFrequencyread-writecurrentThis object defines how often the task will be run. When set to hourly(1), the task will be run every hour. When set to daily(2), the task will be run every da…
1.3.6.1.4.1.10418.26.2.1.10.1.6ColumnacsScheduledTasksTableDayread-writecurrentOnly used if acsScheduledTasksTableFrequency is set to weekly(3). The task will be run every week on this day, at the time specified by acsScheduledTasksTableT…
1.3.6.1.4.1.10418.26.2.1.10.1.7ColumnacsScheduledTasksTableDateread-writecurrentOnly used if acsScheduledTasksTableFrequency is set to monthly(4). The task will be run every month on this day, at the time specified by acsScheduledTasksTabl…
1.3.6.1.4.1.10418.26.2.1.10.1.8ColumnacsScheduledTasksTableTimeread-writecurrentThe time of day the task will run. Format must be HH:MM.
1.3.6.1.4.1.10418.26.2.1.10.1.9ColumnacsScheduledTasksTableLastStartedread-onlycurrentThe timestamp of the last time the task started running.
1.3.6.1.4.1.10418.26.2.1.10.1.10ColumnacsScheduledTasksTableLastResultread-onlycurrentThe result of the last time the task was run.
1.3.6.1.4.1.10418.26.2.1.10.1.11ColumnacsScheduledTasksTableScriptread-writecurrentThe script command used by the task. Only used if acsScheduledTasksTableType is set to custom(1).
1.3.6.1.4.1.10418.26.2.1.10.1.12ColumnacsScheduledTasksTableIpAddressread-writecurrentThe IP address used by the cell-modem-ip task. Not used by all tasks.
1.3.6.1.4.1.10418.26.2.2NodeacsSessions
1.3.6.1.4.1.10418.26.2.2.1ScalaracsActiveSessionsNumberOfSessionread-onlycurrentNumber of active sessions.
1.3.6.1.4.1.10418.26.2.2.2TableacsActiveSessionsTablenot-accessiblecurrentThis table contains the list of active sessions.
1.3.6.1.4.1.10418.26.2.2.2.1RowacsActiveSessionsTableEntrynot-accessiblecurrenteach entry has the information about the active session
1.3.6.1.4.1.10418.26.2.2.2.1.1ColumnacsActiveSessionsTableIndexread-onlycurrentA unique index representing an entry in this table.
1.3.6.1.4.1.10418.26.2.2.2.1.2ColumnacsActiveSessionsTableUserread-onlycurrentThe name of the user that opens this session.
1.3.6.1.4.1.10418.26.2.2.2.1.3ColumnacsActiveSessionsTableGroupread-onlycurrentThe name of the group that the user belongs to.
1.3.6.1.4.1.10418.26.2.2.2.1.4ColumnacsActiveSessionsTableTyperead-onlycurrentThe session type.
1.3.6.1.4.1.10418.26.2.2.2.1.5ColumnacsActiveSessionsTableConnectionread-onlycurrentConnection type.
1.3.6.1.4.1.10418.26.2.2.2.1.6ColumnacsActiveSessionsTableSessionTimeread-onlycurrentTime of the session
1.3.6.1.4.1.10418.26.2.2.2.1.7ColumnacsActiveSessionsTableFromread-onlycurrentThe source IP address of the session.
1.3.6.1.4.1.10418.26.2.2.2.1.8ColumnacsActiveSessionsTableKillread-writecurrentA set value of killSession(2) will kill the session. noAction(1) = always returned in a GET. Does nothing if SET. killSession(2)= when SET the appliance immedi…
1.3.6.1.4.1.10418.26.2.3NodeacsSerialPort
1.3.6.1.4.1.10418.26.2.3.1ScalaracsSerialPortNumberOfPortsread-onlycurrentNumber of Serial Ports (physical serial port plus Aux Port.
1.3.6.1.4.1.10418.26.2.3.2TableacsSerialPortTablenot-accessiblecurrentThis table contains information about serial ports.
1.3.6.1.4.1.10418.26.2.3.2.1RowacsSerialPortTableEntrynot-accessiblecurrenteach entry has the information about specific serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.1ColumnacsSerialPortTableNumberread-onlycurrentA unique index representing an entry in this table. It is the number of the serial port. For AUX port, the number will be the number of physical serial ports p…
1.3.6.1.4.1.10418.26.2.3.2.1.2ColumnacsSerialPortTableDeviceNameread-onlycurrentThe associated device name for the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.3ColumnacsSerialPortTableStatusread-onlycurrentThe status of the serial port: disabled(1) = it was configured as disable. idle(2) = there is not any session opened in this port. inUse(3) = there is session(…
1.3.6.1.4.1.10418.26.2.3.2.1.4ColumnacsSerialPortTableNameread-onlycurrentName associated with this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.5ColumnacsSerialPortTableProfileread-onlycurrentConfigured profile for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.6ColumnacsSerialPortTablePinOutread-onlycurrentRJ45 Pin-out configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.7ColumnacsSerialPortTableComSpeedread-onlycurrentSpeed configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.8ColumnacsSerialPortTableComParityread-onlycurrentParity configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.9ColumnacsSerialPortTableComDataSizeread-onlycurrentData Size configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.10ColumnacsSerialPortTableComStopBitsread-onlycurrentNumber of Stop Bits configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.11ColumnacsSerialPortTableComFlowControlread-onlycurrentFlow Control configured for this serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.12ColumnacsSerialPortTableSignalStateDTRread-onlycurrentState of the DTR RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.13ColumnacsSerialPortTableSignalStateDCDread-onlycurrentState of the DCD RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.14ColumnacsSerialPortTableSignalStateRTSread-onlycurrentState of the RTS RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.15ColumnacsSerialPortTableSignalStateCTSread-onlycurrentState of the CTS RS-232C signal.
1.3.6.1.4.1.10418.26.2.3.2.1.16ColumnacsSerialPortTableTxBytesread-onlycurrentThe number of transmited bytes by the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.17ColumnacsSerialPortTableRxBytesread-onlycurrentThe number of received bytes by the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.18ColumnacsSerialPortTableFrameErrorread-onlycurrentThe number of frame error detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.19ColumnacsSerialPortTableParityErrorread-onlycurrentThe number of parity error detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.20ColumnacsSerialPortTableBreakread-onlycurrentThe number of break detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.21ColumnacsSerialPortTableOverrunread-onlycurrentThe number of overrun error detected in the serial port.
1.3.6.1.4.1.10418.26.2.3.2.1.22ColumnacsSerialPortTableResetCountersread-writecurrentResets counters for all statistics for this serial port. Resets the countes for TxBytes, RxBytes, frame errors, parity errors, breaks, and overrun errors.
1.3.6.1.4.1.10418.26.2.3.2.1.23ColumnacsSerialPortTableXcvrStatusread-onlycurrentActivity status of the RS232 transceiver.
1.3.6.1.4.1.10418.26.2.5NodeacsPowerMgmt
1.3.6.1.4.1.10418.26.2.5.1ScalaracsPowerMgmtNumSerialPortsread-onlycurrentThe number of Serial Ports that has PDU connected on the appliance.
1.3.6.1.4.1.10418.26.2.5.2TableacsPowerMgmtSerialTablenot-accessiblecurrentInformation about each serial port thas has PDU connect.
1.3.6.1.4.1.10418.26.2.5.2.1RowacsPowerMgmtSerialTableEntrynot-accessiblecurrentInformation about each serial port thas has PDU connect.
1.3.6.1.4.1.10418.26.2.5.2.1.1ColumnacsPowerMgmtSerialTableIndexread-onlycurrentThe index of the register.
1.3.6.1.4.1.10418.26.2.5.2.1.2ColumnacsPowerMgmtSerialTablePortNumberread-onlycurrentThe number of the serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.2.1.3ColumnacsPowerMgmtSerialTableDeviceNameread-onlycurrentThe device name of this serial port.
1.3.6.1.4.1.10418.26.2.5.2.1.4ColumnacsPowerMgmtSerialTableNumberPDUsread-onlycurrentTotal number of units connected in this serial port.
1.3.6.1.4.1.10418.26.2.5.2.1.5ColumnacsPowerMgmtSerialTableNumberUPSread-onlycurrentTotal number of UPS devices connected to this serial port.
1.3.6.1.4.1.10418.26.2.5.3TableacsPowerMgmtPDUTablenot-accessiblecurrentThis table contains the list of detected PDUs.
1.3.6.1.4.1.10418.26.2.5.3.1RowacsPowerMgmtPDUTableEntrynot-accessiblecurrenteach entry has the information about the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.1ColumnacsPowerMgmtPDUTablePortNumberread-onlycurrentNumber of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.3.1.2ColumnacsPowerMgmtPDUTablePduIndexread-onlycurrentA PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.3.1.3ColumnacsPowerMgmtPDUTablePduIdread-onlycurrentPDU identification.
1.3.6.1.4.1.10418.26.2.5.3.1.4ColumnacsPowerMgmtPDUTablePortNameread-onlycurrentName of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.3.1.5ColumnacsPowerMgmtPDUTableModelread-onlycurrentModel of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.6ColumnacsPowerMgmtPDUTableVendorread-onlycurrentVendor of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.7ColumnacsPowerMgmtPDUTableFirmwareVersionread-onlycurrentVersion of the PDU firmware.
1.3.6.1.4.1.10418.26.2.5.3.1.8ColumnacsPowerMgmtPDUTableNumberOfOutletsread-onlycurrentNumber of outlets of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.9ColumnacsPowerMgmtPDUTableCurrentNOSread-onlyobsoleteNumber of current sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.10ColumnacsPowerMgmtPDUTableCurrent1Valueread-onlyobsoleteCurrent of the sensor 1 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : valu…
1.3.6.1.4.1.10418.26.2.5.3.1.11ColumnacsPowerMgmtPDUTableCurrent1Maxread-writeobsoleteMaximum current of the sensor 1 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is…
1.3.6.1.4.1.10418.26.2.5.3.1.12ColumnacsPowerMgmtPDUTableCurrent2Valueread-onlyobsoleteCurrent of the sensor 2 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : valu…
1.3.6.1.4.1.10418.26.2.5.3.1.13ColumnacsPowerMgmtPDUTableCurrent2Maxread-writeobsoleteMaximum current of the sensor 2 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is…
1.3.6.1.4.1.10418.26.2.5.3.1.14ColumnacsPowerMgmtPDUTableCurrent3Valueread-onlyobsoleteCurrent of the sensor 3 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : valu…
1.3.6.1.4.1.10418.26.2.5.3.1.15ColumnacsPowerMgmtPDUTableCurrent3Maxread-writeobsoleteMaximum current of the sensor 3 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is…
1.3.6.1.4.1.10418.26.2.5.3.1.16ColumnacsPowerMgmtPDUTableTemperatureNOSread-onlyobsoleteNumber of temperature sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.17ColumnacsPowerMgmtPDUTableTemperature1Valueread-onlyobsoleteTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (E…
1.3.6.1.4.1.10418.26.2.5.3.1.18ColumnacsPowerMgmtPDUTableTemperature1Maxread-writeobsoleteMaximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this…
1.3.6.1.4.1.10418.26.2.5.3.1.19ColumnacsPowerMgmtPDUTableTemperature2Valueread-onlyobsoleteTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (E…
1.3.6.1.4.1.10418.26.2.5.3.1.20ColumnacsPowerMgmtPDUTableTemperature2Maxread-writeobsoleteMaximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this…
1.3.6.1.4.1.10418.26.2.5.3.1.21ColumnacsPowerMgmtPDUTableTemperature3Valueread-onlyobsoleteTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (E…
1.3.6.1.4.1.10418.26.2.5.3.1.22ColumnacsPowerMgmtPDUTableTemperature3Maxread-writeobsoleteMaximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this…
1.3.6.1.4.1.10418.26.2.5.3.1.23ColumnacsPowerMgmtPDUTableHumidityNOSread-onlyobsoleteNumber of humidity sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.24ColumnacsPowerMgmtPDUTableHumidity1Valueread-onlyobsoleteHumidity of this PM unit . If the humidity measurement is not installed this value will be 0.
1.3.6.1.4.1.10418.26.2.5.3.1.25ColumnacsPowerMgmtPDUTableHumidity1Maxread-writeobsoleteMaximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0…
1.3.6.1.4.1.10418.26.2.5.3.1.26ColumnacsPowerMgmtPDUTableHumidity2Valueread-onlyobsoleteHumidity of this PM unit . If the humidity measurement is not installed this value will be 0.
1.3.6.1.4.1.10418.26.2.5.3.1.27ColumnacsPowerMgmtPDUTableHumidity2Maxread-writeobsoleteMaximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0…
1.3.6.1.4.1.10418.26.2.5.3.1.28ColumnacsPowerMgmtPDUTableHumidity3Valueread-onlyobsoleteHumidity of this PM unit . If the humidity measurement is not installed this value will be 0.
1.3.6.1.4.1.10418.26.2.5.3.1.29ColumnacsPowerMgmtPDUTableHumidity3Maxread-writeobsoleteMaximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0…
1.3.6.1.4.1.10418.26.2.5.3.1.30ColumnacsPowerMgmtPDUTableVoltageNOSread-onlyobsoleteNumber of voltage sensors in the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.31ColumnacsPowerMgmtPDUTableVoltage1Valueread-onlyobsoleteVoltage of this sensor in this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.32ColumnacsPowerMgmtPDUTableVoltage1Maxread-writeobsoleteMaximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.33ColumnacsPowerMgmtPDUTableVoltage2Valueread-onlyobsoleteVoltage of this sensor in this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.34ColumnacsPowerMgmtPDUTableVoltage2Maxread-writeobsoleteMaximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.35ColumnacsPowerMgmtPDUTableVoltage3Valueread-onlyobsoleteVoltage of this sensor in this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.36ColumnacsPowerMgmtPDUTableVoltage3Maxread-writeobsoleteMaximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.37ColumnacsPowerMgmtPDUTableNumberOfPhasesread-onlycurrentNumber of phases of this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.38ColumnacsPowerMgmtPDUTableNumberOfBanksread-onlycurrentNumber of banks of this PDU unit.
1.3.6.1.4.1.10418.26.2.5.3.1.39ColumnacsPowerMgmtPDUTableCurrentValueread-onlycurrentActual value of current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.40ColumnacsPowerMgmtPDUTableCurrentMaxread-onlycurrentMax detected value of current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.41ColumnacsPowerMgmtPDUTableCurrentMinread-onlycurrentMin detected value of current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.42ColumnacsPowerMgmtPDUTableCurrentAvgread-onlycurrentAverage value for current sensor in this PDU.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.43ColumnacsPowerMgmtPDUTableCurrentResetread-writecurrentReset max, min and avg values of current.
1.3.6.1.4.1.10418.26.2.5.3.1.44ColumnacsPowerMgmtPDUTableVoltageTyperead-onlycurrentType of voltage values.
1.3.6.1.4.1.10418.26.2.5.3.1.45ColumnacsPowerMgmtPDUTableVoltageValueread-onlycurrentActual value of voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.46ColumnacsPowerMgmtPDUTableVoltageMaxread-onlycurrentMax detected value of voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.47ColumnacsPowerMgmtPDUTableVoltageMinread-onlycurrentMin detected value of voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.48ColumnacsPowerMgmtPDUTableVoltageAvgread-onlycurrentAverage value for voltage sensor in this PDU unit.( V )
1.3.6.1.4.1.10418.26.2.5.3.1.49ColumnacsPowerMgmtPDUTableVoltageResetread-writecurrentReset max, min and avg values of voltage.
1.3.6.1.4.1.10418.26.2.5.3.1.50ColumnacsPowerMgmtPDUTablePowerTyperead-onlycurrentType of power consumption values.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.51ColumnacsPowerMgmtPDUTablePowerValueread-onlycurrentActual value of power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.52ColumnacsPowerMgmtPDUTablePowerMaxread-onlycurrentMax detected value of power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.53ColumnacsPowerMgmtPDUTablePowerMinread-onlycurrentMin detected value of power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.54ColumnacsPowerMgmtPDUTablePowerAvgread-onlycurrentAverage value for power consumption in this PDU unit.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.3.1.55ColumnacsPowerMgmtPDUTablePowerResetread-writecurrentReset max, min and avg values of power consumption.
1.3.6.1.4.1.10418.26.2.5.3.1.56ColumnacsPowerMgmtPDUTablePowerFactorTyperead-onlycurrentType of power factor values.
1.3.6.1.4.1.10418.26.2.5.3.1.57ColumnacsPowerMgmtPDUTablePowerFactorValueread-onlycurrentActual value of power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.58ColumnacsPowerMgmtPDUTablePowerFactorMaxread-onlycurrentMax detected value of power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.59ColumnacsPowerMgmtPDUTablePowerFactorMinread-onlycurrentMin detected value of power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.60ColumnacsPowerMgmtPDUTablePowerFactorAvgread-onlycurrentAverage value for power factor in this PDU unit.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.3.1.61ColumnacsPowerMgmtPDUTablePowerFactorResetread-writecurrentReset max, min and avg values of power factor.
1.3.6.1.4.1.10418.26.2.5.3.1.62ColumnacsPowerMgmtPDUTableAlarmread-onlycurrentShow the PDU alarm status.
1.3.6.1.4.1.10418.26.2.5.3.1.63ColumnacsPowerMgmtPDUTableEnvSensorsread-onlycurrentNumber of environmental sensor in this PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.64ColumnacsPowerMgmtPDUTableAgentSerialNumberread-onlycurrentSerial number of the agent.
1.3.6.1.4.1.10418.26.2.5.3.1.65ColumnacsPowerMgmtPDUTablePduModelNumberread-onlycurrentModel number of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.66ColumnacsPowerMgmtPDUTablePduSerialNumberread-onlycurrentSerial number of the PDU.
1.3.6.1.4.1.10418.26.2.5.3.1.67ColumnacsPowerMgmtPDUTablePduPartNumberread-onlycurrentPart number of the PDU.
1.3.6.1.4.1.10418.26.2.5.4ScalaracsPowerMgmtTotalNumberOfOutletsread-onlycurrentNumber of outlets managed by the appliance.
1.3.6.1.4.1.10418.26.2.5.5TableacsPowerMgmtOutletsTablenot-accessiblecurrentThis table contains the information about outlets.
1.3.6.1.4.1.10418.26.2.5.5.1RowacsPowerMgmtOutletsTableEntrynot-accessiblecurrenteach entry has the information about the outlet.
1.3.6.1.4.1.10418.26.2.5.5.1.1ColumnacsPowerMgmtOutletsTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.5.1.2ColumnacsPowerMgmtOutletsTablePduNumberread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.5.1.3ColumnacsPowerMgmtOutletsTableNumberread-onlycurrentNumber of the outlet in the PDU.
1.3.6.1.4.1.10418.26.2.5.5.1.4ColumnacsPowerMgmtOutletsTableNameread-onlycurrentName of the outlet.
1.3.6.1.4.1.10418.26.2.5.5.1.5ColumnacsPowerMgmtOutletsTableStatusread-onlycurrentStatus of the outlet.
1.3.6.1.4.1.10418.26.2.5.5.1.6ColumnacsPowerMgmtOutletsTablePowerControlread-writecurrentA set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is…
1.3.6.1.4.1.10418.26.2.5.5.1.7ColumnacsPowerMgmtOutletsTablePortNameread-onlycurrentSerial Port Name where the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.5.1.8ColumnacsPowerMgmtOutletsTablePduIdread-onlycurrentPDU identification.
1.3.6.1.4.1.10418.26.2.5.6ScalaracsPowerMgmtNumberOfOutletGroupread-onlycurrentNumber of configured group of outlets.
1.3.6.1.4.1.10418.26.2.5.7TableacsPowerMgmtGroupTablenot-accessiblecurrentThis table contains the information about group of outlets.
1.3.6.1.4.1.10418.26.2.5.7.1RowacsPowerMgmtGroupTableEntrynot-accessiblecurrenteach entry has the information about group of outlets.
1.3.6.1.4.1.10418.26.2.5.7.1.1ColumnacsPowerMgmtGroupTableIndexread-onlycurrentIndex of the group.
1.3.6.1.4.1.10418.26.2.5.7.1.2ColumnacsPowerMgmtGroupTableNameread-onlycurrentName of the group of outlets.
1.3.6.1.4.1.10418.26.2.5.7.1.3ColumnacsPowerMgmtGroupTableStatusread-onlycurrentStatus of the group of outlet.
1.3.6.1.4.1.10418.26.2.5.7.1.4ColumnacsPowerMgmtGroupTablePowerControlread-writecurrentA set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is…
1.3.6.1.4.1.10418.26.2.5.8TableacsPowerMgmtPhasesTablenot-accessiblecurrentThis table contains data monitoring of each detected phase.
1.3.6.1.4.1.10418.26.2.5.8.1RowacsPowerMgmtPhasesTableEntrynot-accessiblecurrenteach entry has the data monitoring about phases.
1.3.6.1.4.1.10418.26.2.5.8.1.1ColumnacsPowerMgmtPhasesTablePortNumberread-onlycurrentNumber of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.8.1.2ColumnacsPowerMgmtPhasesTablePduIndexread-onlycurrentA PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.8.1.3ColumnacsPowerMgmtPhasesTablePhaseIndexread-onlycurrentphase index in the PDU.
1.3.6.1.4.1.10418.26.2.5.8.1.4ColumnacsPowerMgmtPhasesTablePhaseNameread-onlycurrentphase name in the PDU.
1.3.6.1.4.1.10418.26.2.5.8.1.5ColumnacsPowerMgmtPhasesTablePduIdread-onlycurrentPDU identification.
1.3.6.1.4.1.10418.26.2.5.8.1.6ColumnacsPowerMgmtPhasesTablePortNameread-onlycurrentName of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.8.1.7ColumnacsPowerMgmtPhasesTableCurrentValueread-onlycurrentActual value of current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.8ColumnacsPowerMgmtPhasesTableCurrentMaxread-onlycurrentMax detected value of current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.9ColumnacsPowerMgmtPhasesTableCurrentMinread-onlycurrentMin detected value of current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.10ColumnacsPowerMgmtPhasesTableCurrentAvgread-onlycurrentAverage value for current sensor in this phase.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.11ColumnacsPowerMgmtPhasesTableCurrentResetread-writecurrentReset max, min and avg values of current.
1.3.6.1.4.1.10418.26.2.5.8.1.12ColumnacsPowerMgmtPhasesTableVoltageTyperead-onlycurrentType of voltage values.
1.3.6.1.4.1.10418.26.2.5.8.1.13ColumnacsPowerMgmtPhasesTableVoltageValueread-onlycurrentActual value of voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.14ColumnacsPowerMgmtPhasesTableVoltageMaxread-onlycurrentMax detected value of voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.15ColumnacsPowerMgmtPhasesTableVoltageMinread-onlycurrentMin detected value of voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.16ColumnacsPowerMgmtPhasesTableVoltageAvgread-onlycurrentAverage value for voltage sensor in this phase.( V )
1.3.6.1.4.1.10418.26.2.5.8.1.17ColumnacsPowerMgmtPhasesTableVoltageResetread-writecurrentReset max, min and avg values of voltage.
1.3.6.1.4.1.10418.26.2.5.8.1.18ColumnacsPowerMgmtPhasesTablePowerTyperead-onlycurrentType of power consumption values.
1.3.6.1.4.1.10418.26.2.5.8.1.19ColumnacsPowerMgmtPhasesTablePowerValueread-onlycurrentActual value of power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.20ColumnacsPowerMgmtPhasesTablePowerMaxread-onlycurrentMax detected value of power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.21ColumnacsPowerMgmtPhasesTablePowerMinread-onlycurrentMin detected value of power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.22ColumnacsPowerMgmtPhasesTablePowerAvgread-onlycurrentAverage value for power consumption in this phase.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.8.1.23ColumnacsPowerMgmtPhasesTablePowerResetread-writecurrentReset max, min and avg values of power consumption.
1.3.6.1.4.1.10418.26.2.5.8.1.24ColumnacsPowerMgmtPhasesTablePowerFactorTyperead-onlycurrentType of power factor values.
1.3.6.1.4.1.10418.26.2.5.8.1.25ColumnacsPowerMgmtPhasesTablePowerFactorValueread-onlycurrentActual value of power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.26ColumnacsPowerMgmtPhasesTablePowerFactorMaxread-onlycurrentMax detected value of power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.27ColumnacsPowerMgmtPhasesTablePowerFactorMinread-onlycurrentMin detected value of power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.28ColumnacsPowerMgmtPhasesTablePowerFactorAvgread-onlycurrentAverage value for power factor in this phase.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.8.1.29ColumnacsPowerMgmtPhasesTablePowerFactorResetread-writecurrentReset max, min and avg values of power factor.
1.3.6.1.4.1.10418.26.2.5.8.1.30ColumnacsPowerMgmtPhasesTableAlarmread-onlycurrentShow the phase alarm status.
1.3.6.1.4.1.10418.26.2.5.9TableacsPowerMgmtBanksTablenot-accessiblecurrentThis table contains data monitoring of each detected bank.
1.3.6.1.4.1.10418.26.2.5.9.1RowacsPowerMgmtBanksTableEntrynot-accessiblecurrenteach entry has the data monitoring about bank.
1.3.6.1.4.1.10418.26.2.5.9.1.1ColumnacsPowerMgmtBanksTablePortNumberread-onlycurrentNumber of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.9.1.2ColumnacsPowerMgmtBanksTablePduIndexread-onlycurrentA PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.9.1.3ColumnacsPowerMgmtBanksTableBankIndexread-onlycurrentBank index in the PDU.
1.3.6.1.4.1.10418.26.2.5.9.1.4ColumnacsPowerMgmtBanksTableBankNameread-onlycurrentBank name in the PDU.
1.3.6.1.4.1.10418.26.2.5.9.1.5ColumnacsPowerMgmtBanksTablePduIdread-onlycurrentPDU identification.
1.3.6.1.4.1.10418.26.2.5.9.1.6ColumnacsPowerMgmtBanksTablePortNameread-onlycurrentName of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.9.1.7ColumnacsPowerMgmtBanksTableCurrentValueread-onlycurrentActual value of current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.8ColumnacsPowerMgmtBanksTableCurrentMaxread-onlycurrentMax detected value of current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.9ColumnacsPowerMgmtBanksTableCurrentMinread-onlycurrentMin detected value of current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.10ColumnacsPowerMgmtBanksTableCurrentAvgread-onlycurrentAverage value for current sensor in this bank.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.11ColumnacsPowerMgmtBanksTableCurrentResetread-writecurrentReset max, min and avg values of current.
1.3.6.1.4.1.10418.26.2.5.9.1.12ColumnacsPowerMgmtBanksTableVoltageTyperead-onlycurrentType of voltage values.
1.3.6.1.4.1.10418.26.2.5.9.1.13ColumnacsPowerMgmtBanksTableVoltageValueread-onlycurrentActual value of voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.14ColumnacsPowerMgmtBanksTableVoltageMaxread-onlycurrentMax detected value of voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.15ColumnacsPowerMgmtBanksTableVoltageMinread-onlycurrentMin detected value of voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.16ColumnacsPowerMgmtBanksTableVoltageAvgread-onlycurrentAverage value for voltage sensor in this bank.( V )
1.3.6.1.4.1.10418.26.2.5.9.1.17ColumnacsPowerMgmtBanksTableVoltageResetread-writecurrentReset max, min and avg values of voltage.
1.3.6.1.4.1.10418.26.2.5.9.1.18ColumnacsPowerMgmtBanksTablePowerTyperead-onlycurrentType of power consumption values.
1.3.6.1.4.1.10418.26.2.5.9.1.19ColumnacsPowerMgmtBanksTablePowerValueread-onlycurrentActual value of power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.20ColumnacsPowerMgmtBanksTablePowerMaxread-onlycurrentMax detected value of power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.21ColumnacsPowerMgmtBanksTablePowerMinread-onlycurrentMin detected value of power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.22ColumnacsPowerMgmtBanksTablePowerAvgread-onlycurrentAverage value for power consumption in this bank.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.9.1.23ColumnacsPowerMgmtBanksTablePowerResetread-writecurrentReset max, min and avg values of power consumption.
1.3.6.1.4.1.10418.26.2.5.9.1.24ColumnacsPowerMgmtBanksTablePowerFactorTyperead-onlycurrentType of power factor values.
1.3.6.1.4.1.10418.26.2.5.9.1.25ColumnacsPowerMgmtBanksTablePowerFactorValueread-onlycurrentActual value of power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.26ColumnacsPowerMgmtBanksTablePowerFactorMaxread-onlycurrentMax detected value of power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.27ColumnacsPowerMgmtBanksTablePowerFactorMinread-onlycurrentMin detected value of power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.28ColumnacsPowerMgmtBanksTablePowerFactorAvgread-onlycurrentAverage value for power factor in this bank.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.9.1.29ColumnacsPowerMgmtBanksTablePowerFactorResetread-writecurrentReset max, min and avg values of power factor.
1.3.6.1.4.1.10418.26.2.5.9.1.30ColumnacsPowerMgmtBanksTableAlarmread-onlycurrentShow the bank alarm status.
1.3.6.1.4.1.10418.26.2.5.10TableacsPowerMgmtEnvMonTablenot-accessiblecurrentThis table contains data monitoring of each detected environmental sensor.
1.3.6.1.4.1.10418.26.2.5.10.1RowacsPowerMgmtEnvMonTableEntrynot-accessiblecurrenteach entry has the data monitoring about environmental sensors.
1.3.6.1.4.1.10418.26.2.5.10.1.1ColumnacsPowerMgmtEnvMonTablePortNumberread-onlycurrentNumber of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.10.1.2ColumnacsPowerMgmtEnvMonTablePduIndexread-onlycurrentA PDU position in the chain.
1.3.6.1.4.1.10418.26.2.5.10.1.3ColumnacsPowerMgmtEnvMonTableIndexread-onlycurrentenvmon sensor index.
1.3.6.1.4.1.10418.26.2.5.10.1.4ColumnacsPowerMgmtEnvMonTableNameread-onlycurrentenvmon sensor name.
1.3.6.1.4.1.10418.26.2.5.10.1.5ColumnacsPowerMgmtEnvMonTablePduIdread-onlycurrentPDU identification.
1.3.6.1.4.1.10418.26.2.5.10.1.6ColumnacsPowerMgmtEnvMonTablePortNameread-onlycurrentName of serial port when the PDU is connected.
1.3.6.1.4.1.10418.26.2.5.10.1.7ColumnacsPowerMgmtEnvMonTableTyperead-onlycurrentThe type of environmental monitor.
1.3.6.1.4.1.10418.26.2.5.10.1.8ColumnacsPowerMgmtEnvMonTableStatusread-onlycurrentStatus of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor, Door-Contact, Leak, A2D. For Door-Contact, normal(1) = closed, triggered(2) =…
1.3.6.1.4.1.10418.26.2.5.10.1.9ColumnacsPowerMgmtEnvMonTableValueread-onlycurrentDetected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu.
1.3.6.1.4.1.10418.26.2.5.10.1.10ColumnacsPowerMgmtEnvMonTableMaxValueread-onlycurrentMax detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu. Voltage VDC x 100. Current x 100.
1.3.6.1.4.1.10418.26.2.5.11TableacsPowerMgmtOutElecMonTablenot-accessiblecurrentThis table contains the information about data monitoring of outlets.
1.3.6.1.4.1.10418.26.2.5.11.1RowacsPowerMgmtOutElecMonTableEntrynot-accessiblecurrenteach entry has the information about the outlet.
1.3.6.1.4.1.10418.26.2.5.11.1.1ColumnacsPowerMgmtOutElecMonTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.11.1.2ColumnacsPowerMgmtOutElecMonTablePduNumberread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.11.1.3ColumnacsPowerMgmtOutElecMonTableNumberread-onlycurrentNumber of the outlet in the PDU.
1.3.6.1.4.1.10418.26.2.5.11.1.4ColumnacsPowerMgmtOutElecMonTableCurrentValueread-onlycurrentActual value of outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.5ColumnacsPowerMgmtOutElecMonTableCurrentMaxread-onlycurrentMax detected value of outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.6ColumnacsPowerMgmtOutElecMonTableCurrentMinread-onlycurrentMin detected value of outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.7ColumnacsPowerMgmtOutElecMonTableCurrentAvgread-onlycurrentAverage value for outlet current sensor.( A x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.8ColumnacsPowerMgmtOutElecMonTableCurrentResetread-writecurrentReset max, min and avertage values of outlet current.
1.3.6.1.4.1.10418.26.2.5.11.1.9ColumnacsPowerMgmtOutElecMonTablePowerValueread-onlycurrentActual value of outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.10ColumnacsPowerMgmtOutElecMonTablePowerMaxread-onlycurrentMax detected value of outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.11ColumnacsPowerMgmtOutElecMonTablePowerMinread-onlycurrentMin detected value of outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.12ColumnacsPowerMgmtOutElecMonTablePowerAvgread-onlycurrentAverage value for outlet power comsumption sensor.( W x 10 )
1.3.6.1.4.1.10418.26.2.5.11.1.13ColumnacsPowerMgmtOutElecMonTablePowerResetread-writecurrentReset max, min and avertage values of outlet power comsumption.
1.3.6.1.4.1.10418.26.2.5.11.1.14ColumnacsPowerMgmtOutElecMonTableVoltageValueread-onlycurrentActual value of outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.15ColumnacsPowerMgmtOutElecMonTableVoltageMaxread-onlycurrentMax detected value of outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.16ColumnacsPowerMgmtOutElecMonTableVoltageMinread-onlycurrentMin detected value of outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.17ColumnacsPowerMgmtOutElecMonTableVoltageAvgread-onlycurrentAverage value for outlet voltage sensor.( V )
1.3.6.1.4.1.10418.26.2.5.11.1.18ColumnacsPowerMgmtOutElecMonTableVoltageResetread-writecurrentReset max, min and avertage values of outlet voltage.
1.3.6.1.4.1.10418.26.2.5.11.1.19ColumnacsPowerMgmtOutElecMonTablePowerFactorValueread-onlycurrentActual value of outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.20ColumnacsPowerMgmtOutElecMonTablePowerFactorMaxread-onlycurrentMax detected value of outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.21ColumnacsPowerMgmtOutElecMonTablePowerFactorMinread-onlycurrentMin detected value of outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.22ColumnacsPowerMgmtOutElecMonTablePowerFactorAvgread-onlycurrentAverage value for outlet power-factor sensor.( PF x 100 )
1.3.6.1.4.1.10418.26.2.5.11.1.23ColumnacsPowerMgmtOutElecMonTablePowerFactorResetread-writecurrentReset max, min and avertage values of outlet power-factor.
1.3.6.1.4.1.10418.26.2.5.11.1.24ColumnacsPowerMgmtOutElecMonTableAlarmread-onlycurrentShow the outlet alarm status.
1.3.6.1.4.1.10418.26.2.5.12TableacsPowerMgmtUPSTablenot-accessiblecurrentThis table contains the list of detected UPSs.
1.3.6.1.4.1.10418.26.2.5.12.1RowacsPowerMgmtUPSTableEntrynot-accessiblecurrentEach entry has the information about the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1.1ColumnacsPowerMgmtUPSTablePortNumberread-onlycurrentNumber of serial port when the UPS is connected.
1.3.6.1.4.1.10418.26.2.5.12.1.2ColumnacsPowerMgmtUPSTableUpsIndexread-onlycurrentA UPS position in the chain.
1.3.6.1.4.1.10418.26.2.5.12.1.3ColumnacsPowerMgmtUPSTableUpsIdread-onlycurrentUPS identification.
1.3.6.1.4.1.10418.26.2.5.12.1.4ColumnacsPowerMgmtUPSTablePortNameread-onlycurrentName of serial port or IP address if network device
1.3.6.1.4.1.10418.26.2.5.12.1.5ColumnacsPowerMgmtUPSTableModelread-onlycurrentModel of the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1.6ColumnacsPowerMgmtUPSTableVendorread-onlycurrentVendor of the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1.7ColumnacsPowerMgmtUPSTableFirmwareVersionread-onlycurrentVersion of the UPS firmware.
1.3.6.1.4.1.10418.26.2.5.12.1.8ColumnacsPowerMgmtUPSTableAgentFirmwareVersionread-onlycurrentFirmware version of the agent card.
1.3.6.1.4.1.10418.26.2.5.12.1.9ColumnacsPowerMgmtUPSTableSystemStatusread-onlycurrentSystem Status of the UPS.
1.3.6.1.4.1.10418.26.2.5.12.1.10ColumnacsPowerMgmtUPSTableInputBlackOutCountread-onlycurrentThe number of occurrences, since the last reset, where the input was not qualified to provide power to the system.
1.3.6.1.4.1.10418.26.2.5.12.1.11ColumnacsPowerMgmtUPSTableInputBrownOutCountread-onlycurrentThe number of occurrences, since the last reset, where the system input voltage has fallen below a pre-determined threshold for a specified amount of time.
1.3.6.1.4.1.10418.26.2.5.12.1.12ColumnacsPowerMgmtUPSTableInletAirTemperatureread-onlycurrentTemperature of the inlet air.
1.3.6.1.4.1.10418.26.2.5.12.1.13ColumnacsPowerMgmtUPSTableNumberOutletGroupsread-onlycurrentThe number of Outlet Groups on this UPS
1.3.6.1.4.1.10418.26.2.5.12.1.14ColumnacsPowerMgmtUPSTableUPSSerialNumberread-onlycurrentSystem serial number.
1.3.6.1.4.1.10418.26.2.5.12.1.15ColumnacsPowerMgmtUPSTableUPSManufactureDateread-onlycurrentManufacturing date of the system.
1.3.6.1.4.1.10418.26.2.5.12.1.16ColumnacsPowerMgmtUPSTableAutoRestartDelayread-writecurrentIf power is lost, the control will delay this amount of time after power is restored before restarting the unit.
1.3.6.1.4.1.10418.26.2.5.12.1.17ColumnacsPowerMgmtUPSTableAutoRestartControlread-writecurrentWhen set to enabled, the UPS will automatically restart the load when utility power is restored after a battery discharge.
1.3.6.1.4.1.10418.26.2.5.12.1.18ColumnacsPowerMgmtUPSTableAudibleAlarmControlread-writecurrentAudible alarm control.
1.3.6.1.4.1.10418.26.2.5.12.1.19ColumnacsPowerMgmtUPSTableSilenceAlarmread-writecurrentSilence audible alarm.
1.3.6.1.4.1.10418.26.2.5.12.1.20ColumnacsPowerMgmtUPSTableInverterStateread-onlycurrentInverter on/off state.
1.3.6.1.4.1.10418.26.2.5.12.1.21ColumnacsPowerMgmtUPSTableDCConverterStatusread-onlycurrentThe operating state of the dc converter.
1.3.6.1.4.1.10418.26.2.5.12.1.22ColumnacsPowerMgmtUPSTableShutdownReasonread-onlycurrentThe reason for the most recent shutdown.
1.3.6.1.4.1.10418.26.2.5.12.1.23ColumnacsPowerMgmtUPSTableUPSTopologyread-onlycurrentUPS Topology.
1.3.6.1.4.1.10418.26.2.5.12.1.24ColumnacsPowerMgmtUPSTableBypassInverterInputConfigread-onlycurrentInput source configuration for the bypass and inverter.
1.3.6.1.4.1.10418.26.2.5.13TableacsPowerMgmtUPSInputTablenot-accessiblecurrentThis table contains the information about UPS inputs.
1.3.6.1.4.1.10418.26.2.5.13.1RowacsPowerMgmtUPSInputTableEntrynot-accessiblecurrenteach entry has the information about the UPS inputs.
1.3.6.1.4.1.10418.26.2.5.13.1.1ColumnacsPowerMgmtUPSInputTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.13.1.2ColumnacsPowerMgmtUPSInputTableUpsIndexread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.13.1.3ColumnacsPowerMgmtUPSInputTableFrequencyread-onlycurrentInput Frequency.
1.3.6.1.4.1.10418.26.2.5.13.1.4ColumnacsPowerMgmtUPSInputTableRMSVoltageL1Nread-onlycurrentRMS Voltage L1-N.
1.3.6.1.4.1.10418.26.2.5.13.1.5ColumnacsPowerMgmtUPSInputTableRMSVoltageL1L2read-onlycurrentRMS Voltage L1L2.
1.3.6.1.4.1.10418.26.2.5.13.1.6ColumnacsPowerMgmtUPSInputTableRMSVoltageL2Nread-onlycurrentRMS Voltage L2N.
1.3.6.1.4.1.10418.26.2.5.13.1.7ColumnacsPowerMgmtUPSInputTableRMSCurrentL1read-onlycurrentRMS Current for L1.
1.3.6.1.4.1.10418.26.2.5.13.1.8ColumnacsPowerMgmtUPSInputTableRMSCurrentL2read-onlycurrentRMS Current for L2.
1.3.6.1.4.1.10418.26.2.5.13.1.9ColumnacsPowerMgmtUPSInputTableMaxVoltageL1Nread-onlycurrentInput Max Voltage measurement for Line L1-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.10ColumnacsPowerMgmtUPSInputTableMinVoltageL1Nread-onlycurrentInput Min Voltage measurement for Line L1-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.11ColumnacsPowerMgmtUPSInputTableMaxVoltageL2Nread-onlycurrentInput Max Voltage measurement for Line L2-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.12ColumnacsPowerMgmtUPSInputTableMinVoltageL2Nread-onlycurrentInput Min Voltage measurement for Line L1-N since the last reset.
1.3.6.1.4.1.10418.26.2.5.13.1.13ColumnacsPowerMgmtUPSInputTableNominalVoltageread-onlycurrentInput nominal voltage.
1.3.6.1.4.1.10418.26.2.5.13.1.14ColumnacsPowerMgmtUPSInputTableNominalFrequencyread-onlycurrentInput nominal frequency.
1.3.6.1.4.1.10418.26.2.5.13.1.15ColumnacsPowerMgmtUPSInputTableNominalCurrentread-onlycurrentInput nominal current.
1.3.6.1.4.1.10418.26.2.5.13.1.16ColumnacsPowerMgmtUPSInputTableEnergyread-onlycurrentInput Energy.
1.3.6.1.4.1.10418.26.2.5.13.1.17ColumnacsPowerMgmtUPSInputTablePowerFactorL1Nread-onlycurrentInput Power Factor for Line 1.
1.3.6.1.4.1.10418.26.2.5.13.1.18ColumnacsPowerMgmtUPSInputTablePowerFactorL2Nread-onlycurrentInput Power Factor for Line 2.
1.3.6.1.4.1.10418.26.2.5.14TableacsPowerMgmtUPSBypassTablenot-accessiblecurrentThis table contains the information about UPS bypass.
1.3.6.1.4.1.10418.26.2.5.14.1RowacsPowerMgmtUPSBypassTableEntrynot-accessiblecurrenteach entry has the information about the UPS bypass.
1.3.6.1.4.1.10418.26.2.5.14.1.1ColumnacsPowerMgmtUPSBypassTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.14.1.2ColumnacsPowerMgmtUPSBypassTableUpsIndexread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.14.1.3ColumnacsPowerMgmtUPSBypassTableRMSVoltageL1Nread-onlycurrentRMS Voltage L1N.
1.3.6.1.4.1.10418.26.2.5.14.1.4ColumnacsPowerMgmtUPSBypassTableRMSVoltageL1L2read-onlycurrentRMS Voltage L1L2.
1.3.6.1.4.1.10418.26.2.5.14.1.5ColumnacsPowerMgmtUPSBypassTableRMSVoltageL2Nread-onlycurrentRMS Voltage L2N.
1.3.6.1.4.1.10418.26.2.5.14.1.6ColumnacsPowerMgmtUPSBypassTableRMSCurrentread-onlycurrentRMS Current.
1.3.6.1.4.1.10418.26.2.5.14.1.7ColumnacsPowerMgmtUPSBypassTableRMSCurrentL2read-onlycurrentRMS Current.
1.3.6.1.4.1.10418.26.2.5.14.1.8ColumnacsPowerMgmtUPSBypassTableInputFrequencyread-onlycurrentBypass Input Frequency.
1.3.6.1.4.1.10418.26.2.5.14.1.9ColumnacsPowerMgmtUPSBypassTableNominalVoltageread-onlycurrentBypass Nominal Voltage.
1.3.6.1.4.1.10418.26.2.5.15TableacsPowerMgmtUPSBatteryTablenot-accessiblecurrentThis table contains the information about UPS battery.
1.3.6.1.4.1.10418.26.2.5.15.1RowacsPowerMgmtUPSBatteryTableEntrynot-accessiblecurrenteach entry has the information about the UPS bypass.
1.3.6.1.4.1.10418.26.2.5.15.1.1ColumnacsPowerMgmtUPSBatteryTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.15.1.2ColumnacsPowerMgmtUPSBatteryTableUpsIndexread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.15.1.3ColumnacsPowerMgmtUPSBatteryTableDCBusVoltageread-onlycurrentDC Bus Voltage
1.3.6.1.4.1.10418.26.2.5.15.1.4ColumnacsPowerMgmtUPSBatteryTableTimeRemainingread-onlycurrentThe calculated available time on battery.
1.3.6.1.4.1.10418.26.2.5.15.1.5ColumnacsPowerMgmtUPSBatteryTablePercentageChargeread-onlycurrentBattery Percentage Charge.
1.3.6.1.4.1.10418.26.2.5.15.1.6ColumnacsPowerMgmtUPSBatteryTableChargeStatusread-onlycurrentBattery Charge Status.
1.3.6.1.4.1.10418.26.2.5.15.1.7ColumnacsPowerMgmtUPSBatteryTableLowBatteryWarningTimeread-writecurrentWhen battery time remaining falls to, or below, this value (minutes) the low battery alarm is activated.
1.3.6.1.4.1.10418.26.2.5.15.1.8ColumnacsPowerMgmtUPSBatteryTableTestResultread-onlycurrentThe outcome of the previous battery test.
1.3.6.1.4.1.10418.26.2.5.15.1.9ColumnacsPowerMgmtUPSBatteryTableDCBusNominalVoltageread-onlycurrentBattery DC Bus Nominal Voltage.
1.3.6.1.4.1.10418.26.2.5.15.1.10ColumnacsPowerMgmtUPSBatteryTableNominalBatteryCapacityread-onlycurrentNominal Battery Capacity.
1.3.6.1.4.1.10418.26.2.5.15.1.11ColumnacsPowerMgmtUPSBatteryTableBatteryFloatVoltageread-onlycurrentBattery Float Voltage.
1.3.6.1.4.1.10418.26.2.5.15.1.12ColumnacsPowerMgmtUPSBatteryTableBatteryCabinetTyperead-onlycurrentBattery Cabinet Type.
1.3.6.1.4.1.10418.26.2.5.15.1.13ColumnacsPowerMgmtUPSBatteryTableBatteryNumberOfEBCread-onlycurrentNumber of Extended Battery Cabinets installed.
1.3.6.1.4.1.10418.26.2.5.15.1.14ColumnacsPowerMgmtUPSBatteryTableBatteryRatingread-onlycurrentBattery Rating.
1.3.6.1.4.1.10418.26.2.5.15.1.15ColumnacsPowerMgmtUPSBatteryTableBatteryDischargeTimeread-onlycurrentTime on battery operation for this discharge
1.3.6.1.4.1.10418.26.2.5.15.1.16ColumnacsPowerMgmtUPSBatteryTableBatteryChargeCompensatingread-onlycurrentBattery charge algorithm changed due to battery temperature.
1.3.6.1.4.1.10418.26.2.5.15.1.17ColumnacsPowerMgmtUPSBatteryTableBatteryChargerStateread-onlycurrentBattery charger state.
1.3.6.1.4.1.10418.26.2.5.15.1.18ColumnacsPowerMgmtUPSBatteryTableStartBatteryTestread-writecurrentCommand to initate a manual battery test.
1.3.6.1.4.1.10418.26.2.5.15.1.19ColumnacsPowerMgmtUPSBatteryTableBatteryStatusread-onlycurrentBattery Status.
1.3.6.1.4.1.10418.26.2.5.15.1.20ColumnacsPowerMgmtUPSBatteryTableBatteryTotalDischargeTimeread-onlycurrentCumulative battery discharge time.
1.3.6.1.4.1.10418.26.2.5.15.1.21ColumnacsPowerMgmtUPSBatteryTableBatteryDischargeCountread-onlycurrentTotal number of battery discharges.
1.3.6.1.4.1.10418.26.2.5.15.1.22ColumnacsPowerMgmtUPSBatteryTableBatteryCurrentread-onlycurrentCurrent at the battery input terminals. In charging mode, the current will be a positive value. In discharging mode, the current will be a negative value.
1.3.6.1.4.1.10418.26.2.5.16TableacsPowerMgmtUPSOutputTablenot-accessiblecurrentThis table contains the information about UPS output.
1.3.6.1.4.1.10418.26.2.5.16.1RowacsPowerMgmtUPSOutputTableEntrynot-accessiblecurrentEach entry has the information about the UPS output.
1.3.6.1.4.1.10418.26.2.5.16.1.1ColumnacsPowerMgmtUPSOutputTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.16.1.2ColumnacsPowerMgmtUPSOutputTableUpsIndexread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.16.1.3ColumnacsPowerMgmtUPSOutputTableApparentPowerread-onlycurrentDC Bus Voltage
1.3.6.1.4.1.10418.26.2.5.16.1.4ColumnacsPowerMgmtUPSOutputTableFrequencyread-onlycurrentOutput frequency.
1.3.6.1.4.1.10418.26.2.5.16.1.5ColumnacsPowerMgmtUPSOutputTablePercentPowerread-onlycurrentThe system output power as a percentage of the rated capacity.
1.3.6.1.4.1.10418.26.2.5.16.1.6ColumnacsPowerMgmtUPSOutputTablePercentPowerL1read-onlycurrentThe system output power on line L1 as a percentage of the rated capacity.
1.3.6.1.4.1.10418.26.2.5.16.1.7ColumnacsPowerMgmtUPSOutputTablePercentPowerL2read-onlycurrentThe system output power on line L2 as a percentage of the rated capacity.
1.3.6.1.4.1.10418.26.2.5.16.1.8ColumnacsPowerMgmtUPSOutputTablePowerread-onlycurrentThe sum total power of all system output phases.
1.3.6.1.4.1.10418.26.2.5.16.1.9ColumnacsPowerMgmtUPSOutputTableRMSCurrentL1read-onlycurrentSystem output RMS current for line L1.
1.3.6.1.4.1.10418.26.2.5.16.1.10ColumnacsPowerMgmtUPSOutputTableRMSCurrentL2read-onlycurrentSystem output RMS current for line L2.
1.3.6.1.4.1.10418.26.2.5.16.1.11ColumnacsPowerMgmtUPSOutputTableRMSVoltageL1Nread-onlycurrentThe system output RMS voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.12ColumnacsPowerMgmtUPSOutputTableRMSVoltageL2Nread-onlycurrentThe system output RMS voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.13ColumnacsPowerMgmtUPSOutputTableRMSVoltageL1L2read-onlycurrentThe system output RMS voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.14ColumnacsPowerMgmtUPSOutputOffDelayread-writecurrentTurns the UPS output off after the number of seconds specified. When a value is written to this object the output will be turned off after the specified time h…
1.3.6.1.4.1.10418.26.2.5.16.1.15ColumnacsPowerMgmtUPSOutputOnDelayread-writecurrentTurns the UPS output on after the number of seconds specified. When a value is written to this object the output will be turned on after the specified time has…
1.3.6.1.4.1.10418.26.2.5.16.1.16ColumnacsPowerMgmtUPSOutputCycleDelayread-writecurrentTurns the UPS off and then back on after the number of seconds specified. When a value is written to this object the output will turned off immediately and the…
1.3.6.1.4.1.10418.26.2.5.16.1.17ColumnacsPowerMgmtUPSOutputTableMaxVoltageL1read-onlycurrentThe maximum system output voltage measurement for line 1 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.18ColumnacsPowerMgmtUPSOutputTableMinVoltageL1read-onlycurrentThe minimum system output voltage measurement for line 1 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.19ColumnacsPowerMgmtUPSOutputTableMaxVoltageL2read-onlycurrentThe maximum system output voltage measurement for line 21 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.20ColumnacsPowerMgmtUPSOutputTableMinVoltageL2read-onlycurrentThe minimum system output voltage measurement for line 2 since the last reset.
1.3.6.1.4.1.10418.26.2.5.16.1.21ColumnacsPowerMgmtUPSOutputTableNominalVoltageread-onlycurrentThe nominal (or rated) system output voltage.
1.3.6.1.4.1.10418.26.2.5.16.1.22ColumnacsPowerMgmtUPSOutputTablePowerNominalFrequencyread-onlycurrentThe nominal (or rated) system output frequency.
1.3.6.1.4.1.10418.26.2.5.16.1.23ColumnacsPowerMgmtUPSOutputTablePowerApparentPowerRatingread-onlycurrentOutput apparent power rating.
1.3.6.1.4.1.10418.26.2.5.16.1.24ColumnacsPowerMgmtUPSOutputTablePowerNominalPowerFactorread-onlycurrentThe nominal (or rated) system power factor.
1.3.6.1.4.1.10418.26.2.5.16.1.25ColumnacsPowerMgmtUPSOutputTablePowerPowerFactorCorrectionread-onlycurrentThe state of the power factor correction circuitry of the system.
1.3.6.1.4.1.10418.26.2.5.16.1.26ColumnacsPowerMgmtUPSOutputTablePowerL1read-onlycurrentThe system output power on line 1.
1.3.6.1.4.1.10418.26.2.5.16.1.27ColumnacsPowerMgmtUPSOutputTablePowerL2read-onlycurrentThe system output power on line 2.
1.3.6.1.4.1.10418.26.2.5.16.1.28ColumnacsPowerMgmtUPSOutputTableApparentPowerL1read-onlycurrentThe system output apparent power on line 1.
1.3.6.1.4.1.10418.26.2.5.16.1.29ColumnacsPowerMgmtUPSOutputTableApparentPowerL2read-onlycurrentThe system output apparent power on line 2.
1.3.6.1.4.1.10418.26.2.5.16.1.30ColumnacsPowerMgmtUPSOutputTablePowerFactorL1read-onlycurrentThe system output power factor on line 1.
1.3.6.1.4.1.10418.26.2.5.16.1.31ColumnacsPowerMgmtUPSOutputTablePowerFactorL2read-onlycurrentThe system output power factor on line 2.
1.3.6.1.4.1.10418.26.2.5.17TableacsPowerMgmtUPSEcoModeTablenot-accessiblecurrentThis table contains the information about UPS ECO Mode.
1.3.6.1.4.1.10418.26.2.5.17.1RowacsPowerMgmtUPSEcoModeTableEntrynot-accessiblecurrenteach entry has the information about the UPS ECO Mode.
1.3.6.1.4.1.10418.26.2.5.17.1.1ColumnacsPowerMgmtUPSEcoModeTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.17.1.2ColumnacsPowerMgmtUPSEcoModeTableUpsIndexread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.17.1.3ColumnacsPowerMgmtUPSEcoModeTableStatusread-onlycurrentCurrent ECO Mode Status.
1.3.6.1.4.1.10418.26.2.5.17.1.4ColumnacsPowerMgmtUPSEcoModeTableStateControlread-writecurrentEnable or disable ECO mode.
1.3.6.1.4.1.10418.26.2.5.18TableacsPowerMgmtUPSOutletGroupTablenot-accessiblecurrentThis table contains the UPS Outlet Group Information.
1.3.6.1.4.1.10418.26.2.5.18.1RowacsPowerMgmtUPSOutletGroupTableEntrynot-accessiblecurrentEach entry has the UPS outlet group information.
1.3.6.1.4.1.10418.26.2.5.18.1.1ColumnacsPowerMgmtUPSOutletGroupTablePortNumberread-onlycurrentSerial Port number.
1.3.6.1.4.1.10418.26.2.5.18.1.2ColumnacsPowerMgmtUPSOutletGroupTableUpsIndexread-onlycurrentIndex.
1.3.6.1.4.1.10418.26.2.5.18.1.3ColumnacsPowerMgmtUPSOutletGroupTableNumberread-onlycurrentNumber of the outletgroup in the UPS.
1.3.6.1.4.1.10418.26.2.5.18.1.4ColumnacsPowerMgmtUPSOutletGroupTableLabelread-onlycurrentUser-defined label for the outlet group.
1.3.6.1.4.1.10418.26.2.5.18.1.5ColumnacsPowerMgmtUPSOutletGroupTableStateread-onlycurrentUser-defined label for the outlet group.
1.3.6.1.4.1.10418.26.2.5.18.1.6ColumnacsPowerMgmtUPSOutletGroupTablePowerControlread-writecurrentA set value of power(2-6) will send command to the UPS. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command…
1.3.6.1.4.1.10418.26.2.6NodeacsTrapObject
1.3.6.1.4.1.10418.26.2.7NodeacsSensors
1.3.6.1.4.1.10418.26.2.7.1ScalaracsSensorsInternalCurrentCPUTemperatureread-onlycurrentThe current CPU temperature in degrees Celsius.
1.3.6.1.4.1.10418.26.2.7.2ScalaracsSensorsInternalMaxCPUTemperatureread-writecurrentThe CPU temperature in degrees Celsius that, if exceeded, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.3ScalaracsSensorsInternalMaxCPUTemperatureThresholdread-writecurrentThe CPU temperature threshold in degrees Celsius below the maximum CPU temperature. When the temperature exceeds the Maximum Temperature plus Threshold, an eve…
1.3.6.1.4.1.10418.26.2.7.4ScalaracsSensorsInternalMinCPUTemperatureread-writecurrentThe CPU temperature in degrees Celsius that, if the CPU temperature falls below, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.5ScalaracsSensorsInternalMinCPUTemperatureThresholdread-writecurrentThe CPU temperature threshold in degrees Celsius above the minimum CPU temperature.
1.3.6.1.4.1.10418.26.2.7.6ScalaracsSensorsInternalCurrentBoardTemperatureread-onlycurrentThe current board temperature in degrees Celsius.
1.3.6.1.4.1.10418.26.2.7.7ScalaracsSensorsInternalMaxBoardTemperatureread-writecurrentThe board temperature in degrees Celsius that, if exceeded, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.8ScalaracsSensorsInternalMaxBoardTemperatureThresholdread-writecurrentThe board temperature threshold in degrees Celsius below the maximum board temperature. When the temperature exceeds the Maximum Temperature plus Threshold, an…
1.3.6.1.4.1.10418.26.2.7.9ScalaracsSensorsInternalMinBoardTemperatureread-writecurrentThe board temperature in degrees Celsius that, if the board temperature falls below, will generate an event notification.
1.3.6.1.4.1.10418.26.2.7.10ScalaracsSensorsInternalMinBoardTemperatureThresholdread-writecurrentThe board temperature threshold in degrees Celsius above the minimum board temperature.
1.3.6.1.4.1.10418.26.2.7.11ScalaracsSensorsVoltagePSInternalread-onlycurrentThe PS Internal Supply voltage [0.95v ~ 1.05v] x 100.
1.3.6.1.4.1.10418.26.2.7.12ScalaracsSensorsVoltagePLInternalread-onlycurrentThe PL Internal Supply voltage [0.95v ~ 1.05v] x 100.
1.3.6.1.4.1.10418.26.2.7.13ScalaracsSensorsVoltagePSAuxiliaryread-onlycurrentThe PS Auxiliary Supply voltage [1.71v ~ 1.89v] x 100.
1.3.6.1.4.1.10418.26.2.7.14ScalaracsSensorsVoltagePLAuxiliaryread-onlycurrentThe PL Auxiliary Supply voltage [1.71v ~ 1.89v] x 100.
1.3.6.1.4.1.10418.26.2.7.15ScalaracsSensorsVoltagePSDDR3read-onlycurrentThe PS DDR3 Supply voltage [1.31v ~ 1.39v] x 100.
1.3.6.1.4.1.10418.26.2.7.16ScalaracsSensorsVoltagePLBlockRamread-onlycurrentThe PL Block RAM Supply voltage [0.95v ~ 1.05v] x 100.
1.3.6.1.4.1.10418.26.2.7.17ScalaracsSensorsVoltagePowerSupply1read-onlycurrentThe Power Supply 1 voltage [11.06v ~ 12.98v] x 100.
1.3.6.1.4.1.10418.26.2.7.18ScalaracsSensorsVoltagePowerSupply2read-onlycurrentThe Power Supply 2 voltage [11.06v ~ 12.98v] x 100.
1.3.6.1.4.1.10418.26.2.7.19ScalaracsSensors1WireUpdateControlread-writecurrentA set value of update(2) will refresh the 1-wire sensor list.
1.3.6.1.4.1.10418.26.2.7.20TableacsSensors1WireTablenot-accessiblecurrentThis table contains the list of detected external 1-wire sensors.
1.3.6.1.4.1.10418.26.2.7.20.1RowacsSensors1WireTableEntrynot-accessiblecurrentEach entry has the information about the external 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.1ColumnacsSensors1WireTableIndexread-onlycurrentIndex of detected 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.2ColumnacsSensors1WireTableNameread-writecurrentName of the 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.3ColumnacsSensors1WireTableLocationread-writecurrentLocation of the 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.4ColumnacsSensors1WireTableAddressread-onlycurrentAddress of the 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.5ColumnacsSensors1WireTableTyperead-onlycurrentType of 1-wire sensor.
1.3.6.1.4.1.10418.26.2.7.20.1.6ColumnacsSensors1WireTableUnitread-onlycurrentThe unit of the 1-wire sensor. notApplicable(0) = used for contact or leak sensor celsius(1) = used for temperature sensor fahrenheit(2) = used for temperature…
1.3.6.1.4.1.10418.26.2.7.20.1.7ColumnacsSensors1WireTableValueread-onlycurrentCurrent sensor reading.
1.3.6.1.4.1.10418.26.2.7.20.1.8ColumnacsSensors1WireTableValueMaxread-onlycurrentMaximum sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.9ColumnacsSensors1WireTableValueMinread-onlycurrentMinimum sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.10ColumnacsSensors1WireTableValueAvgread-onlycurrentAverage sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.11ColumnacsSensors1WireTableValueLowWarningread-onlycurrentIf the sensor value falls below this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.12ColumnacsSensors1WireTableValueLowCriticalread-writecurrentIf the sensor value falls below this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.13ColumnacsSensors1WireTableValueHighWarningread-writecurrentIf the sensor value rises above this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.14ColumnacsSensors1WireTableValueHighCriticalread-writecurrentIf the sensor value rises above this value, an event notification will be generated. Unit is specified in acsSensors1WireTableUnit.
1.3.6.1.4.1.10418.26.2.7.20.1.15ColumnacsSensors1WireTableResetread-writecurrentA set value of update(2) will reset the 1-wire sensor min/max/avg values.
1.3.6.1.4.1.10418.26.2.7.20.1.16ColumnacsSensors1WireTableAnalogAlarmread-writecurrentStatus of the 1-wire analog sensor alarm. Used for temperature, humidity, and differential pressure sensors only. For all other sensor types the value notAppli…
1.3.6.1.4.1.10418.26.2.7.20.1.17ColumnacsSensors1WireTableContactAlarm1read-writecurrentStatus of the 1-wire contact sensor alarm. Used for door and dry contact sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.18ColumnacsSensors1WireTableContactAlarm2read-writecurrentStatus of the 1-wire contact sensor alarm. Used for door and dry contact sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.19ColumnacsSensors1WireTableContactAlarm3read-writecurrentStatus of the 1-wire contact sensor alarm. Used for door and dry contact sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.20ColumnacsSensors1WireTableLeakFilterTimeread-writecurrentLeak filter time in seconds.
1.3.6.1.4.1.10418.26.2.7.20.1.21ColumnacsSensors1WireTableLeakAlarmread-writecurrentStatus of the leak alarm for the leak sensor. Used for leak sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.20.1.22ColumnacsSensors1WireTableLeakCableFailAlarmread-writecurrentStatus of the cable fail alarm for the leak sensor. Used for leak sensors only. For all other sensor types the value notApplicable(0) will be returned.
1.3.6.1.4.1.10418.26.2.7.21TableacsSensorsDigitalInTablenot-accessiblecurrentThis table contains the list of Digital In sensors.
1.3.6.1.4.1.10418.26.2.7.21.1RowacsSensorsDigitalInTableEntrynot-accessiblecurrentEach entry has the information about the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.1ColumnacsSensorsDigitalInTablePositionread-onlycurrentPosition of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.2ColumnacsSensorsDigitalInTableNameread-writecurrentName of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.3ColumnacsSensorsDigitalInTableLocationread-writecurrentLocation of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.4ColumnacsSensorsDigitalInTableTyperead-writecurrentConfigurable type of Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.5ColumnacsSensorsDigitalInTableValueread-onlycurrentValue of the Digital In sensor.
1.3.6.1.4.1.10418.26.2.7.21.1.6ColumnacsSensorsDigitalInTableAlarmread-writecurrentStatus of the Digital In sensor alarm.
1.3.6.1.4.1.10418.26.2.8NodeacsModems
1.3.6.1.4.1.10418.26.2.8.1ScalaracsModemsNumberOfModemsread-onlycurrentNumber of modems, including auxiliary port built-in modems, pluggable USB modems, and serial port modems.
1.3.6.1.4.1.10418.26.2.8.2TableacsModemsTablenot-accessiblecurrentThis table contains information about the ACS modems, including auxiliary port built-in modem, pluggable USB modems, and serial port modems.
1.3.6.1.4.1.10418.26.2.8.2.1RowacsModemsTableEntrynot-accessiblecurrentEach entry has the information about a specific modem.
1.3.6.1.4.1.10418.26.2.8.2.1.1ColumnacsModemsTableNumberread-onlycurrentA unique index representing an entry in this table.
1.3.6.1.4.1.10418.26.2.8.2.1.2ColumnacsModemsTableDeviceNameread-onlycurrentThe associated device name for the modem.
1.3.6.1.4.1.10418.26.2.8.2.1.3ColumnacsModemsTableStatusread-writecurrentEnables or disbles the modem.
1.3.6.1.4.1.10418.26.2.8.2.1.4ColumnacsModemsTableProfileread-writecurrentThe modem profile. For an integrated cell modem, only dial-out(3) is valid.
1.3.6.1.4.1.10418.26.2.8.2.1.5ColumnacsModemsTablePhoneNumberread-writecurrentThe dial-out phone number. Only supported if acsModemsTableProfile is set to dial-out(3). Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.6ColumnacsModemsTableComSpeedread-writecurrentThe modem speed. Speeds above 230400 not supported by serial port modems.
1.3.6.1.4.1.10418.26.2.8.2.1.7ColumnacsModemsTableInitChatread-writecurrentModem initialization string.
1.3.6.1.4.1.10418.26.2.8.2.1.8ColumnacsModemsTablePppAddressConfigread-writecurrentSupported only if acsModemsTableProfile is set to dial-out(2). If none(1) or remote(3) is set, then the IP address fields will be cleared. When at least one IP…
1.3.6.1.4.1.10418.26.2.8.2.1.9ColumnacsModemsTableLocalIpv4Addressread-writecurrentConfigures the local IPv4 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.10ColumnacsModemsTableRemoteIpv4Addressread-writecurrentConfigures the remote IPv4 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.11ColumnacsModemsTableLocalIPv6Addressread-writecurrentConfigures the local IPv6 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.12ColumnacsModemsTableRemoteIPv6Addressread-writecurrentConfigures the remote IPv6 address for the PPP connection.
1.3.6.1.4.1.10418.26.2.8.2.1.13ColumnacsModemsTablePppAuthenticationread-writecurrentConfigure the PPP authentication protocol. If this is set to remoteChap(5) or remotePap(6), then you must also set acsModemsTablePppRemoteUsername and acsModem…
1.3.6.1.4.1.10418.26.2.8.2.1.14ColumnacsModemsTablePppRemoteUsernameread-writecurrentOnly used if acsModemsTablePppAuthentication is set to remoteChap(5) or remotePap(6).
1.3.6.1.4.1.10418.26.2.8.2.1.15ColumnacsModemsTablePppRemotePassphraseread-writecurrentOnly used if acsModemsTablePppAuthentication is set to remoteChap(5) or remotePap(6).
1.3.6.1.4.1.10418.26.2.8.2.1.16ColumnacsModemsTableChapIntervalread-writecurrentCHAP Interval in seconds. Default is 0. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.17ColumnacsModemsTableChapMaxChallengeread-writecurrentCHAP Max Challenge value in seconds. Default is 10 seconds. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.18ColumnacsModemsTableChapRestartread-writecurrentCHAP Restart value in seconds. Default is 3 seconds. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.19ColumnacsModemsTablePppIdleTimeoutread-writecurrentPPP idle timeout value in seconds. Default is 0. Not used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.20ColumnacsModemsTableModelread-onlycurrentModem vendor model name. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.21ColumnacsModemsTableCellProviderread-onlycurrentCellular modem service provider. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.22ColumnacsModemsTableCellRegistrationread-onlycurrentCellular modem network registration. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.23ColumnacsModemsTableCCIDread-onlycurrentSIM integrated circuit card identifier. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.24ColumnacsModemsTableIMSIread-onlycurrentInternational mobile subscriber identity. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.25ColumnacsModemsTableIMEIread-onlycurrentInternational mobile equipment identity. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.26ColumnacsModemsTableCellStatusread-onlycurrentShows the status of the cellular modem. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.27ColumnacsModemsTableAPNread-writecurrentAccess point name. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.28ColumnacsModemsTableMtuSizeread-onlycurrentThe maxiumum transmission unit size for use by the integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.29ColumnacsModemsTableReplaceDefaultRouteread-writecurrentIf this is set to enabled(2), then the integrated cellular modem becomes the default gateway. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.30ColumnacsModemsTablePersistModeread-writecurrentIf this is set to 'yes' then the integrated cellular modem connection persists. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.31ColumnacsModemsTableSignalQualityCheckread-writecurrentCheck the signal quality of the integrated cellular modem. This turns on the modem transceiver to get the signal. The signal quality can be read in acsModemsTa…
1.3.6.1.4.1.10418.26.2.8.2.1.32ColumnacsModemsTableSignalQualityDisplayread-writecurrentDisplays the last read signal quality of the integrated cellular modem. To refresh this value write signalCheck(2) to acsModemsTableSignalQualityCheck.
1.3.6.1.4.1.10418.26.2.8.2.1.33ColumnacsModemsTableSIMStatusread-onlycurrentStatus of the modem SIM card. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.34ColumnacsModemsTableSIMPINEntryread-writecurrentModem SIM card PIN/Password entry. Writable only if acsModemsTableSIMStatus returns waitingForPIN(2). Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.35ColumnacsModemsTableSIMUnlockCodeEntryread-writecurrentModem SIM card Unlock Code entry. Writable only if acsModemsTableSIMStatus returns waitingForUnlockCode(3). Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.36ColumnacsModemsTableCellTestLastStartedread-onlycurrentThe timestamp of the last time the Cell Modem IP Test started running. Only used for integrated cellular modem.
1.3.6.1.4.1.10418.26.2.8.2.1.37ColumnacsModemsTableCellTestLastResultread-onlycurrentThe result of the last time the Cell Modem IP Test was run. Only used for integrated cellular modem.