ADTRAN-AOS-POWER
30 objects
The MIB module for general configuration of power monitoring options for devices with battery backup.
Imported Objects
| ADTRAN-AOS | adGenAOSConformance adGenAOSPower |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.664.5.53.7.0 | NodeadGenAOSPowerTraps | |||
| 1.3.6.1.4.1.664.5.53.7.0.1 | NotificationadGenAOSPowerRollover | current | This trap indicates the unit has had a change in power source, either from AC to DC or back again. The SecSinceEpoch represents the time (seconds since epoch) … | |
| 1.3.6.1.4.1.664.5.53.7.0.2 | NotificationadGenAOSEpsConnectionChange | current | This trap indicates the unit has had a change in the EPS connection state. | |
| 1.3.6.1.4.1.664.5.53.7.0.3 | NotificationadGenAOSEpsDeliveryChange | current | This trap indicates the unit has had a change in the EPS delivery state. | |
| 1.3.6.1.4.1.664.5.53.7.0.4 | NotificationadGenAOSRpsConnectionChange | current | This trap indicates the unit has had a change in the RPS connection state. | |
| 1.3.6.1.4.1.664.5.53.7.0.5 | NotificationadGenAOSRpsDeliveryChange | current | This trap indicates the unit has had a change in the RPS delivery state. | |
| 1.3.6.1.4.1.664.5.53.7.1 | IdentityadGenAOSPowerMonitor | The MIB module for general configuration of power monitoring options for devices with battery backup. | ||
| 1.3.6.1.4.1.664.5.53.7.1.1 | NodeadGenAOSPowerRollOverCtl | |||
| 1.3.6.1.4.1.664.5.53.7.1.1.1 | ScalaradGenAOSPowerRolloverOnAC | read-only | current | Integer value specifying whether or not unit is on AC power. |
| 1.3.6.1.4.1.664.5.53.7.1.1.2 | ScalaradGenAOSPwrRollOvrEvntSecSinceEpoch | accessible-for-notify | current | The time (seconds since epoch) that a power rollover trap was generated. |
| 1.3.6.1.4.1.664.5.53.7.1.2 | NodeadGenAOSPowerEpsRps | |||
| 1.3.6.1.4.1.664.5.53.7.1.2.1 | TableadGenAOSPowerEpsRpsTable | not-accessible | current | EPS/RPS Power Table. |
| 1.3.6.1.4.1.664.5.53.7.1.2.1.1 | RowadGenAOSPowerEpsRpsEntry | not-accessible | current | EPS/RPS entry for a particular VCID. |
| 1.3.6.1.4.1.664.5.53.7.1.2.1.1.1 | ColumnadGenAOSPowerEpsRpsInstanceId | read-only | current | Uniquely identifies a row in the adGenAOSEpsRpsTable. |
| 1.3.6.1.4.1.664.5.53.7.1.2.1.1.2 | ColumnadGenAOSPowerEpsConnectionState | read-only | current | Text value specifying if an EPS is connected or not. |
| 1.3.6.1.4.1.664.5.53.7.1.2.1.1.3 | ColumnadGenAOSPowerEpsDeliveryState | read-only | current | Text value specifying the delivery state of the EPS power. |
| 1.3.6.1.4.1.664.5.53.7.1.2.1.1.4 | ColumnadGenAOSPowerRpsConnectionState | read-only | current | Text value specifying if an RPS is connected or not. |
| 1.3.6.1.4.1.664.5.53.7.1.2.1.1.5 | ColumnadGenAOSPowerRpsDeliveryState | read-only | current | Text value specifying the delivery state of the RPS power. |
| 1.3.6.1.4.1.664.5.53.99.11 | NodeadGenAOSPowerConformance | |||
| 1.3.6.1.4.1.664.5.53.99.11.1 | NodeadGenAOSPowerGroups | |||
| 1.3.6.1.4.1.664.5.53.99.11.1.1 | GroupadGenAOSPowerNotificationGroup | current | Trap which may be used to enhance power event driven management of the Unit. | |
| 1.3.6.1.4.1.664.5.53.99.11.1.2 | GroupadGenAOSPowerRollOverCtlGroup | current | The Unit SNMP Config Group. | |
| 1.3.6.1.4.1.664.5.53.99.11.1.3 | GroupadGenAOSEpsNotificationGroup | current | Trap used to indicate state changes of EPS. | |
| 1.3.6.1.4.1.664.5.53.99.11.1.4 | GroupadGenAOSRpsNotificationGroup | current | Trap used to indicate state changes of RPS. | |
| 1.3.6.1.4.1.664.5.53.99.11.1.5 | GroupadGenAOSEpsRpsConfigurationGroup | current | The Unit SNMP Config Group. | |
| 1.3.6.1.4.1.664.5.53.99.11.2 | NodeadGenAOSPowerCompliances | |||
| 1.3.6.1.4.1.664.5.53.99.11.2.1 | ComplianceadGenAOSPowerFullCompliance | current | The compliance statement for SNMP entities which implement version 2 of the adGenAOSPower MIB. When this MIB is fully implemented, then such an implementation … |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AdEpsPowerDeliveryStateTC | INTEGER { delivering(1), notDelivering(2), failed(3), unknown(4) } | current | Indicates Failure State of a power supply |
| AdPowerConnectionStateTC | INTEGER { connected(1), notConnected(2), notApplicable(3), unknown(4) } | current | Indicates Failure State of a power supply |
| AdRpsPowerDeliveryStateTC | INTEGER { failed(1), busy(2), delivering(3), available(4), unknown(5) } | current | Indicates Failure State of a power supply |