MIB Viewer

ADTRAN-GENESCU-MIB

33 objects
This MIB defines the objects for the genescu MIB.
OIDNameAccessStatusDescription
1.3.6.1.4.1.664.5.17IdentityadGenESCUmgThis MIB defines the objects for the genescu MIB.
1.3.6.1.4.1.664.5.17.1NodeadGenESCUConfig
1.3.6.1.4.1.664.5.17.2NodeadGenESCUProv
1.3.6.1.4.1.664.5.17.2.1TableadGenESCUProvTablenot-accessiblecurrentThe SCU Prov table.
1.3.6.1.4.1.664.5.17.2.1.1RowadGenESCUProvEntrynot-accessiblecurrentAn entry in the SCU Provisioning table.
1.3.6.1.4.1.664.5.17.2.1.1.1ColumnadGenESCUadminPortRateread-writecurrentA Set changes the admin port baud rate to the set value. A Get retrieves the current baud rate.
1.3.6.1.4.1.664.5.17.2.1.1.2ColumnadGenESCUautoLogoffread-writecurrentEnables or disables the Terminal Auto-Logoff.
1.3.6.1.4.1.664.5.17.2.1.1.3ColumnadGenESCUautoLogoffTimerread-writecurrentSelects the Terminal Auto-Logoff time.
1.3.6.1.4.1.664.5.17.2.1.1.4ColumnadGenESCUmoduleAutoProvread-writecurrentEnables or disables Access Module Auto-Provisioning.
1.3.6.1.4.1.664.5.17.2.1.1.5ColumnadGenESCUmuxAutoProvread-writecurrentEnables or disables Mux Auto-Provisioning.
1.3.6.1.4.1.664.5.17.2.1.1.6ColumnadGenESCUrestoreFactoryDefaultsread-writecurrentA Set restores ALL provisioning to the factory defaults. A get is meaningless and always returns a 1.
1.3.6.1.4.1.664.5.17.2.1.1.7ColumnadGenESCUadminPortModeread-writecurrentA Set changes the admin port mode for menus or TL1 access. A Get retrieves the current mode.
1.3.6.1.4.1.664.5.17.2.1.1.8ColumnadGenESCUcraftPortRateread-writecurrentA Set changes the craft port baud rate to the set value. A Get retrieves the current baud rate.
1.3.6.1.4.1.664.5.17.2.1.1.9ColumnadGenESCUadminSecurityEnableread-writecurrentRequire authentication.
1.3.6.1.4.1.664.5.17.3NodeadGenESCUStatus
1.3.6.1.4.1.664.5.17.3.1TableadGenESCUStatusTablenot-accessiblecurrentThe SCU Status table.
1.3.6.1.4.1.664.5.17.3.1.1RowadGenESCUStatusEntrynot-accessiblecurrentAn entry in the SCU Status table.
1.3.6.1.4.1.664.5.17.3.1.1.1ColumnadGenESCUacoStatusread-onlycurrentIndicates whether or not the alarm cut-off is on.
1.3.6.1.4.1.664.5.17.3.1.1.2ColumnadGenESCUacoinStatusread-onlycurrentIndicates whether or not the alarm cut-off input is active.
1.3.6.1.4.1.664.5.17.3.1.1.3ColumnadGenESCUrmtinStatusread-onlycurrentIndicates whether or not the remote alarm input is active.
1.3.6.1.4.1.664.5.17.3.1.1.4ColumnadGenESCUextin1Statusread-onlycurrentIndicates whether or not the external alarm input #1 is active.
1.3.6.1.4.1.664.5.17.3.1.1.5ColumnadGenESCUextin2Statusread-onlycurrentIndicates whether or not the external alarm input #2 is active.
1.3.6.1.4.1.664.5.17.3.1.1.6ColumnadGenESCUminus48PowerAStatusread-onlycurrentIndicates whether or not the minus 48V power supply A is active.
1.3.6.1.4.1.664.5.17.3.1.1.7ColumnadGenESCUminus48PowerBStatusread-onlycurrentIndicates whether or not the minus 48V power supply B is active.
1.3.6.1.4.1.664.5.17.3.1.1.8ColumnadGenESCUopenFuseStatusread-onlycurrentIndicates whether one or more card fuses on this chassis is open.
1.3.6.1.4.1.664.5.17.3.1.1.9ColumnadGenESCUCLLIread-onlycurrentThe Common Language Location Identifier of this chassis, assigned at the craft port.
1.3.6.1.4.1.664.5.17.3.1.1.10ColumnadGenESCUTIRKSIDread-onlycurrentThe Trunk Information Record Keeping System unit number assigned to this shelf, assigned at the craft port.
1.3.6.1.4.1.664.5.17.4NodeadGenESCUTest
1.3.6.1.4.1.664.5.17.4.1TableadGenESCUTestTablenot-accessiblecurrentThe SCU Test table.
1.3.6.1.4.1.664.5.17.4.1.1RowadGenESCUTestEntrynot-accessiblecurrentAn entry in the SCU Test table.
1.3.6.1.4.1.664.5.17.4.1.1.1ColumnadGenESCUResetread-writecurrentA Set restarts the SCU and performs unit self-test. A get always returns a 1.
1.3.6.1.4.1.664.5.17.4.1.1.2ColumnadGenESCUselfTestResultsread-onlycurrentContains the results of the self test performed on startup. This can be from a commanded reset, or card insertion. The text will read 'PASSED', or 'FAILED - xx…
1.3.6.1.4.1.664.5.17.4.1.1.3ColumnadGenESCUChassisLampTestread-writecurrentA set causes the SCU to initiate a lamp test concurrently on every card in the chassis, for a pre-determined duration. A get always returns a 1.