MIB Viewer

ADTRAN-TA5000-THERMAL-MGMT-MIB

17 objects
Total Access 5000 Thermal Management MIB
OIDNameAccessStatusDescription
1.3.6.1.4.1.664.5.67.1.39.1NodeadTA5kThermalMgmtmg
1.3.6.1.4.1.664.5.67.1.39.1.1NodeadTA5kThermal
1.3.6.1.4.1.664.5.67.1.39.1.1.1TableadTA5kThermalSlotTablenot-accessiblecurrentTable of slot indexed OIDs to support this MIB.
1.3.6.1.4.1.664.5.67.1.39.1.1.1.1RowadTA5kThermalSlotEntrynot-accessiblecurrentAn entry in the Thermal Slot Table. This table is indexed by adGenSlotInfoIndex.
1.3.6.1.4.1.664.5.67.1.39.1.1.1.1.1ColumnadTA5kThermalSlotNumSensorsread-onlycurrentThe number of sensors that are accessible on this slot.
1.3.6.1.4.1.664.5.67.1.39.1.1.2TableadTA5kThermalManagementTablenot-accessiblecurrentTable of OIDs indexed by slot and temp sensor id.
1.3.6.1.4.1.664.5.67.1.39.1.1.2.1RowadTA5kThermalManagementEntrynot-accessiblecurrentAn entry in the Thermal Management Table. This table is indexed by adGenSlotInfoIndex and adTA5kThermalManagementSensorId.
1.3.6.1.4.1.664.5.67.1.39.1.1.2.1.1ColumnadTA5kThermalManagementSensorIdnot-accessiblecurrentID of the sensor.
1.3.6.1.4.1.664.5.67.1.39.1.1.2.1.2ColumnadTA5kThermalManagementSensorNameread-onlycurrentThe Human-readable name for this temperature sensor.
1.3.6.1.4.1.664.5.67.1.39.1.1.2.1.3ColumnadTA5kThermalManagementSensorCurrTempread-onlycurrentThe current temperature reported by this temperature sensor, in tenths of a degree celsius.
1.3.6.1.4.1.664.5.67.1.39.2NodeadTA5kThermalEventsFix
1.3.6.1.4.1.664.5.67.1.39.2.0NodeadTa5kThermalEvents
1.3.6.1.4.1.664.5.67.1.39.2.0.1NotificationadTA5kSlotCriticalTempActivecurrentThis trap indicates that the critical temperature threshold for the card has been reached. Indicates whether or not equipment is in danger of shutting down, sh…
1.3.6.1.4.1.664.5.67.1.39.2.0.2NotificationadTA5kSlotCriticalTempClearcurrentThis trap indicates that the critical temperature condition previously declared for this card has now cleared.
1.3.6.1.4.1.664.5.67.1.39.2.0.3NotificationadTa5kRemoteDeviceCriticalTempActivecurrentThis trap indicates that the critical temperature threshold for the remote device has been reached. Indicates whether or not equipment is in danger of shutting…
1.3.6.1.4.1.664.5.67.1.39.2.0.4NotificationadTa5kRemoteDeviceCriticalTempClearcurrentThis trap indicates that the critical temperature condition previously declared for this device has now cleared.
1.3.6.1.4.1.664.6.10000.67.1.39.1IdentityadTa5kThermalMgmtModuleIdentityTotal Access 5000 Thermal Management MIB