ADTRAN-TA5K-GENSLOT-MIB
22 objects
Total Access 5000 GenSlot MIB
Imported Objects
| ADTRAN-GENCHASSIS-MIB | adGenericShelves |
| ADTRAN-GENSLOT-MIB | adGenSlotInfoIndex |
| ADTRAN-GENTA5K-MIB | adGenTa5kSlot adGenTa5kSlotID |
| ADTRAN-TC | AdPresence AdProductIdentifier |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString PhysAddress TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.664.5.67.1.8.1 | TableadGenTa5kSlotTable | not-accessible | current | ... |
| 1.3.6.1.4.1.664.5.67.1.8.1.1 | RowadGenTa5kSlotEntry | not-accessible | current | ... |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.1 | ColumnadGenTa5kSlotRestoreFactoryDefaults | read-write | current | Set used to restore all parameters on the target to factory defaults. The values that can be set may vary for different factory options. The values to set and … |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.2 | ColumnadGenTa5kSlotReboot | read-write | current | Setting this item to 1 will initiate a reboot on the target module. Always returns 1 on get. |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.3 | ColumnadGenTa5kSlotMaxMacs | read-only | current | This returns the number of MAC addresses supported by the target. |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.4 | ColumnadGenTa5kSlotFlashStatus | read-only | current | This item indicates whether or not the non-volatile storage device is currently busy. busy(1) = The storage device is currently in a write operation or a write… |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.5 | ColumnadGenTa5kSlotSystemSwVersion | read-only | current | The TA5000 Module Application System Software Version Number. |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.6 | ColumnadGenTa5kSlotBootSwVersion | read-only | current | The TA5000 Module Boot Software Version Number. |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.7 | ColumnadGenTa5kSlotBootSystemSwVersion | read-only | current | The TA5000 Module Boot System Software Version Number. |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.8 | ColumnadGenTa5kSlotDateOfManufacture | read-only | current | The TA5000 Module's date of manufacture. |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.9 | ColumnadGenTa5kSlotSwVerInstallTime | read-only | current | The install time of the current software image |
| 1.3.6.1.4.1.664.5.67.1.8.1.1.10 | ColumnadGenTa5kSlotIOModuleID | read-only | current | Input-Output Module Part Number and Description |
| 1.3.6.1.4.1.664.5.67.1.8.2 | TableadGenTa5kSlotMacAddressTable | not-accessible | current | This table provides one row for each MAC address entry per slot in a TA5000 system. |
| 1.3.6.1.4.1.664.5.67.1.8.2.1 | RowadGenTa5kSlotMacAddressEntry | not-accessible | current | An entry in the adGenTa5kSlotMacAddressTable. |
| 1.3.6.1.4.1.664.5.67.1.8.2.1.1 | ColumnadGenTa5kSlotMacAddressIndex | not-accessible | current | TA5000 general module MAC Address index. |
| 1.3.6.1.4.1.664.5.67.1.8.2.1.2 | ColumnadGenTa5kSlotMacAddress | read-only | current | Used to get all of the MAC addresses in the selected card. This only applies to modules that require a MAC address. |
| 1.3.6.1.4.1.664.5.67.1.8.3 | TableadGenTa5kSlotDeviceTable | not-accessible | current | This table provides one row for each device entry per slot in a TA5000 system. |
| 1.3.6.1.4.1.664.5.67.1.8.3.1 | RowadGenTa5kSlotDeviceEntry | not-accessible | current | An entry in the adGenTa5kSlotDeviceTable. |
| 1.3.6.1.4.1.664.5.67.1.8.3.1.1 | ColumnadGenTa5kSlotDeviceIndex | not-accessible | current | TA5000 module Device index. |
| 1.3.6.1.4.1.664.5.67.1.8.3.1.2 | ColumnadGenTa5kSlotDeviceDesc | read-only | current | This item returns a string representing the device an FPGA, datapump, etc. |
| 1.3.6.1.4.1.664.5.67.1.8.3.1.3 | ColumnadGenTa5kSlotDeviceRevision | read-only | current | This item returns a string representing the revision or version of a device embedded in the target module such as an FPGA, datapump, etc. |
| 1.3.6.1.4.1.664.6.10000.67.1.8.1 | IdentityadGenTa5kSlotModuleIdentity | Total Access 5000 GenSlot MIB |