ADTRAN-TA5K-GR909-MIB
40 objects
Generic GR909 MIB
Imported Objects
| ADTRAN-GENTA5K-MIB | adGenGr909 adGenGr909ID |
| IF-MIB | ifIndex |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.664.5.67.1.19.1 | TableadGenGr909Table | not-accessible | current | Table of GR909 Table info. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1 | RowadGenGr909Entry | not-accessible | current | |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.1 | ColumnadGenGr909HPTResult | read-only | current | This item indicates the result for the HPT test. Pass(1) = The HPT test Passed. Fail(2) = The HPT test failed. N/A(3) = The HPT test result is not ready. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.2 | ColumnadGenGr909FEMFResult | read-only | current | This item indicates the result for the FEMF test. Pass(1) = The FEMF test Passed. Fail(2) = The FEMF test failed. N/A(3) = The FEMF test result is not ready. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.3 | ColumnadGenGr909RFaultResult | read-only | current | This item indicates the result for the RFault test. Pass(1) = The RFault test Passed. Fail(2) = The RFault test failed. N/A(3) = The RFault test result is not … |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.4 | ColumnadGenGr909RingerResult | read-only | current | This item indicates the result for the Ringer test. Pass(1) = The Ringer test Passed. Fail(2) = The Ringer test failed. N/A(3) = The Ringer test result is not … |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.5 | ColumnadGenGr909ROHResult | read-only | current | This item indicates the result for the ROH test. Pass(1) = The ROH test Passed. Fail(2) = The ROH test failed. N/A(3) = The ROH test result is not ready. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.6 | ColumnadGenGr909FVAcTipToGndMeas | read-only | current | The value for the Foreign Voltage AC Tip to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.7 | ColumnadGenGr909FVAcRingToGndMeas | read-only | current | The value for the Foreign Voltage AC Ring to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.8 | ColumnadGenGr909FVDcTipToGndMeas | read-only | current | The value for the Foreign Voltage DC Tip to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.9 | ColumnadGenGr909FVDcRingToGndMeas | read-only | current | The value for the Foreign Voltage DC Ring to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.10 | ColumnadGenGr909FVAcTipToGndResult | read-only | current | The result for the Foreign Voltage AC Tip to Ground test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.11 | ColumnadGenGr909FVAcRingToGndResult | read-only | current | The result for the Foreign Voltage AC Ring to Ground test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.12 | ColumnadGenGr909FVDcTipToGndResult | read-only | current | The result for the Foreign Voltage DC Tip to Ground test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.13 | ColumnadGenGr909FVDcRingToGndResult | read-only | current | The result for the Foreign Voltage DC Ring to Ground test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.14 | ColumnadGenGr909LoopImpTipToRingMeas | read-only | current | The value for the Loop Impedance Tip to Ring measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.15 | ColumnadGenGr909LoopImpTipToGndMeas | read-only | current | The value for the Loop Impedance Tip to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.16 | ColumnadGenGr909LoopImpRingToGndMeas | read-only | current | The value for the Loop Impedance Ring to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.17 | ColumnadGenGr909LoopImpTipToRingResult | read-only | current | The result for the Loop Impedance Tip to Ring test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.18 | ColumnadGenGr909LoopImpTipToGndResult | read-only | current | The result for the Loop Impedance Tip to Ground test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.19 | ColumnadGenGr909LoopImpRingToGndResult | read-only | current | The result for the Loop Impedance Ring to Ground test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.20 | ColumnadGenGr909RingerMeas | read-only | current | The value for the Ringer measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.21 | ColumnadGenGr909LastTestComplete | read-only | current | The last test time the GR909 test was completed. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.22 | ColumnadGenGr909LastTestAttempt | read-only | current | The last test time the GR909 test was completed. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.23 | ColumnadGenGr909LastTestResult | read-only | current | This item indicates the result for the last test. N/A(1) = The last test result is not valid. Complete(2) = The last test is Complete. Fault(3) = The last test… |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.24 | ColumnadGenGr909FailureCode | read-only | current | The Failure Code for the last GR909 test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.25 | ColumnadGenGr909BeginTest | read-write | current | Begin running the GR909 test. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.26 | ColumnadGenGr909LoopCapTipToRingMeas | read-only | current | The value for the Loop Capacitance Tip to Ring measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.27 | ColumnadGenGr909LoopCapTipToGndMeas | read-only | current | The value for the Loop Capacitance Tip to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.28 | ColumnadGenGr909LoopCapRingToGndMeas | read-only | current | The value for the Loop Capacitance Ring to Ground measurement. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.29 | ColumnadGenGr909IdleNoiseMeasure | read-only | current | Noise on the line. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.30 | ColumnadGenGr909IdleNoiseResult | read-only | current | The result of the noise measurement test on the line. pass(1) = Idle Channel Noise Measurement passed. fail(2) = Idle Channel Noise Measurement exceeded thresh… |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.31 | ColumnadGenGr909NumLoadCoils | read-only | current | Number of load coils on the line. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.32 | ColumnadGenGr909LoadCoilsDistance | read-only | current | Returns a vector of 32-bit unsigned integers (split into octets) containing the measured distance to each detected load coil in feet. If no load coil is detect… |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.33 | ColumnadGenGr909LoadCoilsResult | read-only | current | This item indicates the result for the load coils test. Valid(1) = The load coil test results are valid. Invalid(2) = The load coil test results are invalid. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.34 | ColumnadGenGr909TestFlag | read-write | current | Use to enable/disable the GR909 line tests. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.35 | ColumnadGenGr909TestCapFlag | read-write | current | Use to enable/disable the capacitance test on the line. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.36 | ColumnadGenGr909TestNoiseFlag | read-write | current | Use to enable/disable the noise test on the line. |
| 1.3.6.1.4.1.664.5.67.1.19.1.1.37 | ColumnadGenGr909TestLoadCoilFlag | read-write | current | Use to enable/disable the load coil tests on the line. |
| 1.3.6.1.4.1.664.6.10000.67.1.19.1 | IdentityadGenGr909MIB | Generic GR909 MIB |