AFFIRMED-TEMS-NOTIFICATION-MIB

58 objects
Management Information for notification/alarming the NB NMS / OSS Systems.
OIDNameAccessStatusDescription
1.3.6.1.4.1.37963.6.3.1IdentityaffirmedTemsNotificationsManagement Information for notification/alarming the NB NMS / OSS Systems.
1.3.6.1.4.1.37963.6.3.1.1NodenotificationConfig
1.3.6.1.4.1.37963.6.3.1.1.1ScalarsuppressAlarmsread-writecurrentThis is used to request the EMS Server to stop sending alarms to All the Managers.
1.3.6.1.4.1.37963.6.3.1.2NodenotificationObjects
1.3.6.1.4.1.37963.6.3.1.2.1ScalartemsServerTimeStampaccessible-for-notifycurrentThis object specifies Time at which the Alarm is triggered by the Mgmt Server
1.3.6.1.4.1.37963.6.3.1.2.2ScalaralarmSeverityaccessible-for-notifycurrentThis object indicates the severity of alarm. Clear severity will be used to clear the previously raised alarm
1.3.6.1.4.1.37963.6.3.1.2.3ScalaralarmDiagnosticDataaccessible-for-notifycurrentThis is used as a place holder to include detailed alarm message
1.3.6.1.4.1.37963.6.3.1.2.4ScalarnetworkElementIPAddressaccessible-for-notifycurrentThis is used to indicate the IP-Address of the Network Element serving as the root cause of the problem. However, if the trap is generated by the Mgmt Server i…
1.3.6.1.4.1.37963.6.3.1.2.5ScalarnetworkElementSoftwareVersionaccessible-for-notifycurrentIndicates the current software version of the Network Element being Managed
1.3.6.1.4.1.37963.6.3.1.2.6ScalarcliUserNameaccessible-for-notifycurrentIndicates the User Name used to open the CLI Session with the Network Element
1.3.6.1.4.1.37963.6.3.1.2.7ScalarnotificationAddressaccessible-for-notifycurrentIndicates the E-Mail Address used for Notification
1.3.6.1.4.1.37963.6.3.1.2.8ScalarsourceComponentaccessible-for-notifycurrentIndicates the Component within the Router / Switch responsible for the problem. It is represented in Shelf-Slot-Port format
1.3.6.1.4.1.37963.6.3.1.2.9ScalaralarmCategoryaccessible-for-notifycurrentCategory Assigned for the Alarm. Used as a place holder to differentiate different types of Traps that can be raised from the same component of the equipment
1.3.6.1.4.1.37963.6.3.1.2.10ScalaremsNodeIPAddressaccessible-for-notifycurrentThis is used to indicate the IP-Address of the EMS node for EMS cluster state change notifications.
1.3.6.1.4.1.37963.6.3.1.2.11ScalaremsClusterChangeNotificationDataaccessible-for-notifycurrentIncludes information about the current state of the EMS cluster. This is included with the EMS cluster state change notifications.
1.3.6.1.4.1.37963.6.3.1.2.12ScalarvCenterOldStatusaccessible-for-notifycurrentThis is used by vcenter to indicate the old status in the notification.Sample Values: Gray/Yellow
1.3.6.1.4.1.37963.6.3.1.2.13ScalarvCenterNewStatusaccessible-for-notifycurrentThis is used by vcenter to indicate the new status in the notification.Sample Values: Gray/Yellow
1.3.6.1.4.1.37963.6.3.1.2.14ScalarvCenterTargetObjectTypeaccessible-for-notifycurrentThis is the alarm target object type
1.3.6.1.4.1.37963.6.3.1.2.15ScalaralarmRemedyaccessible-for-notifycurrentIt is used to indicate the potential impact of the alarm and corrective action to remedy.
1.3.6.1.4.1.37963.6.3.1.2.16ScalaralarmAdditionalInfoaccessible-for-notifycurrentIt contain semi-colon separated name/value pairs additional information.
1.3.6.1.4.1.37963.6.3.1.2.17ScalaralarmTrapOIDaccessible-for-notifycurrentIt is used to indicate Trap OID information.
1.3.6.1.4.1.37963.6.3.1.2.18ScalarelementHostNameaccessible-for-notifycurrentIncludes information about the host name of the element.
1.3.6.1.4.1.37963.6.3.1.3NodetemsNorthBoundNotifications
1.3.6.1.4.1.37963.6.3.1.3.1NotificationnetworkElementNotReachablecurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever a managed network element turns unreachable (ICMP).
1.3.6.1.4.1.37963.6.3.1.3.2NotificationnetworkElementNotManageablecurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever a managed network element is reachable via ICMP but not reachable via the …
1.3.6.1.4.1.37963.6.3.1.3.3NotificationnetworkElementManageablecurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to clear the not manageable events raised previously.
1.3.6.1.4.1.37963.6.3.1.3.4NotificationunSupportedNetworkElementVersioncurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever it encounters / discovers a Network element running an Unsupported softwar…
1.3.6.1.4.1.37963.6.3.1.3.5NotificationcliLoginFailedcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever it could not login to the CLI (or TL1) session of the Network Element usin…
1.3.6.1.4.1.37963.6.3.1.3.6NotificationalarmEmailNotificationFailurecurrentManagement Server will send this notification to its NB Clients (NMS / OSS) upon its Failure to send the E-Mail Notification to NB Clients registered for E-Mai…
1.3.6.1.4.1.37963.6.3.1.3.7NotificationdataCollectionFailurecurrentIndicates a Failure during Data Collection. NB managers can either ignore it (or) log-it.
1.3.6.1.4.1.37963.6.3.1.3.8NotificationtemsServerPerfMetricCriticalTCAcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to report a Critical Threshold Crossing Alert, whenever the Critical Threshold limi…
1.3.6.1.4.1.37963.6.3.1.3.9NotificationtemsServerPerfMetricMajorTCAcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to report a Major Threshold Crossing Alert, whenever the Major Threshold limit is c…
1.3.6.1.4.1.37963.6.3.1.3.10NotificationtemsServerPerfMetricMinorTCAcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to report a Minor Threshold Crossing Alert, whenever the Minor Threshold limit is c…
1.3.6.1.4.1.37963.6.3.1.3.11NotificationtemsServerPerfMetricClearTCAcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to Clear the previously raised Critical / Major / Minor TCA for this Performance Me…
1.3.6.1.4.1.37963.6.3.1.3.12NotificationalarmFromNetworkElementcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to report an Alarm Raised due to the occurrence of a trap from the Network Element.…
1.3.6.1.4.1.37963.6.3.1.3.13NotificationhotStandbyTakesOverdeprecatedIndicates a Switchover of the Management server from primary to Standby Server. Note: This alarm will be triggered only when the Management Server is deployed …
1.3.6.1.4.1.37963.6.3.1.3.14NotificationprimaryServerisRestoreddeprecatedIndicates that the Primary Management Server has been restored back in Service. Note: This alarm will be triggered only when the Management Server is deployed …
1.3.6.1.4.1.37963.6.3.1.3.15NotificationalarmfromElementManagementSystemcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to report an Alarm Raised due to the occurence of a trap from the Network Managemen…
1.3.6.1.4.1.37963.6.3.1.3.16NotificationgeoRedundancyGroupMismatchcurrentManagement server will send this notification to its NB clients (NMS / OSS) when it detects mismatch information from EMS, active and standby network element T…
1.3.6.1.4.1.37963.6.3.1.3.17NotificationvnfScaleKpiMonitorAlarmcurrentDynamic VM capacity management KPI monitoring alarms. Source is cluster[vclusterId]/<KPIName> where KPIName can be DCMSession, WSMSession, ASMConn, ASMThruput.…
1.3.6.1.4.1.37963.6.3.1.3.18NotificationvnfScaleOutAlarmcurrentGenerated when VM scale out operation fails Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL. The networkElementIpAddress attribute is po…
1.3.6.1.4.1.37963.6.3.1.3.19NotificationvnfScaleInAlarmcurrentGenerated when VM scale in operation fails Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL. The networkElementIpAddress attribute is pop…
1.3.6.1.4.1.37963.6.3.1.3.20NotificationemsClusterStatusChangeNotificationcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) upon its detection of cluster status change
1.3.6.1.4.1.37963.6.3.1.3.21NotificationalarmFromVCentercurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to report an Alarm Raised due to the occurence of a trap from VCenter Server
1.3.6.1.4.1.37963.6.3.1.3.22NotificationcliLoginSuccesscurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever it could be login to the CLI (or TL1) session of the Network Element using…
1.3.6.1.4.1.37963.6.3.1.3.23NotificationcliTemplateConfigFailedcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever cli template configuration failed.
1.3.6.1.4.1.37963.6.3.1.3.24NotificationcliTemplateConfigSuccesscurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever cli template configuration succeeds.
1.3.6.1.4.1.37963.6.3.1.3.25NotificationalarmtriggeredCliTemplateConfigFailedcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever alarm triggered cli template configuration failed.
1.3.6.1.4.1.37963.6.3.1.3.26NotificationalarmtriggeredCliTemplateConfigSuccesscurrentManagement Server will send this notification to its NB Clients (NMS / OSS) whenever alarm triggered cli template configuration succeeds.
1.3.6.1.4.1.37963.6.3.1.3.27NotificationalarmSnmpNotificationFailurecurrentManagement Server will send this notification to its NB Clients (NMS / OSS) upon its Failure to forward the trap to NB Clients registered for Trap Forwarding.
1.3.6.1.4.1.37963.6.3.1.3.28NotificationmasterSlaveStandbyNodeDowncurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to reports that in cluster topology standby node moved to down state.
1.3.6.1.4.1.37963.6.3.1.3.29NotificationmasterSlaveStandbyNodeUpcurrentManagement Server will send this notification to its NB Clients (NMS / OSS) to reports that in cluster topology standby node moved to up state.
1.3.6.1.4.1.37963.6.3.1.3.31NotificationNBHeartBeatcurrentManagement Server will send this notification to its INFORM supported NB Clients to verify the NB client alive status.
1.3.6.1.4.1.37963.6.3.1.3.32NotificationnetworkElementAutoUnmanagecurrentDevice has been automatically unmanaged due to authentication failure.
1.3.6.1.4.1.37963.6.3.1.3.33NotificationnetworkElementManagecurrentDevice has been managed successfully.
1.3.6.1.4.1.37963.6.3.1.3.34NotificationCUPSConfigurationMismatchcurrentCUPS Configuration mismatch found.
1.3.6.1.4.1.37963.6.3.1.3.35NotificationCUPSConfigurationMatchcurrentCUPS Configuration mismatch cleared.
1.3.6.1.4.1.37963.6.3.1.3.36NotificationCUPSGroupCreationFailedcurrentCUPS Group Creation Failed. Manually remove the config from CPlane.