AFFIRMED-TEMS-NOTIFICATION-MIB
58 objects
Management Information for notification/alarming the NB NMS / OSS Systems.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.37963.6.3.1 | IdentityaffirmedTemsNotifications | Management Information for notification/alarming the NB NMS / OSS Systems. | ||
| 1.3.6.1.4.1.37963.6.3.1.1 | NodenotificationConfig | |||
| 1.3.6.1.4.1.37963.6.3.1.1.1 | ScalarsuppressAlarms | read-write | current | This is used to request the EMS Server to stop sending alarms to All the Managers. |
| 1.3.6.1.4.1.37963.6.3.1.2 | NodenotificationObjects | |||
| 1.3.6.1.4.1.37963.6.3.1.2.1 | ScalartemsServerTimeStamp | accessible-for-notify | current | This object specifies Time at which the Alarm is triggered by the Mgmt Server |
| 1.3.6.1.4.1.37963.6.3.1.2.2 | ScalaralarmSeverity | accessible-for-notify | current | This object indicates the severity of alarm. Clear severity will be used to clear the previously raised alarm |
| 1.3.6.1.4.1.37963.6.3.1.2.3 | ScalaralarmDiagnosticData | accessible-for-notify | current | This is used as a place holder to include detailed alarm message |
| 1.3.6.1.4.1.37963.6.3.1.2.4 | ScalarnetworkElementIPAddress | accessible-for-notify | current | This is used to indicate the IP-Address of the Network Element serving as the root cause of the problem. However, if the trap is generated by the Mgmt Server i… |
| 1.3.6.1.4.1.37963.6.3.1.2.5 | ScalarnetworkElementSoftwareVersion | accessible-for-notify | current | Indicates the current software version of the Network Element being Managed |
| 1.3.6.1.4.1.37963.6.3.1.2.6 | ScalarcliUserName | accessible-for-notify | current | Indicates the User Name used to open the CLI Session with the Network Element |
| 1.3.6.1.4.1.37963.6.3.1.2.7 | ScalarnotificationAddress | accessible-for-notify | current | Indicates the E-Mail Address used for Notification |
| 1.3.6.1.4.1.37963.6.3.1.2.8 | ScalarsourceComponent | accessible-for-notify | current | Indicates the Component within the Router / Switch responsible for the problem. It is represented in Shelf-Slot-Port format |
| 1.3.6.1.4.1.37963.6.3.1.2.9 | ScalaralarmCategory | accessible-for-notify | current | Category Assigned for the Alarm. Used as a place holder to differentiate different types of Traps that can be raised from the same component of the equipment |
| 1.3.6.1.4.1.37963.6.3.1.2.10 | ScalaremsNodeIPAddress | accessible-for-notify | current | This is used to indicate the IP-Address of the EMS node for EMS cluster state change notifications. |
| 1.3.6.1.4.1.37963.6.3.1.2.11 | ScalaremsClusterChangeNotificationData | accessible-for-notify | current | Includes information about the current state of the EMS cluster. This is included with the EMS cluster state change notifications. |
| 1.3.6.1.4.1.37963.6.3.1.2.12 | ScalarvCenterOldStatus | accessible-for-notify | current | This is used by vcenter to indicate the old status in the notification.Sample Values: Gray/Yellow |
| 1.3.6.1.4.1.37963.6.3.1.2.13 | ScalarvCenterNewStatus | accessible-for-notify | current | This is used by vcenter to indicate the new status in the notification.Sample Values: Gray/Yellow |
| 1.3.6.1.4.1.37963.6.3.1.2.14 | ScalarvCenterTargetObjectType | accessible-for-notify | current | This is the alarm target object type |
| 1.3.6.1.4.1.37963.6.3.1.2.15 | ScalaralarmRemedy | accessible-for-notify | current | It is used to indicate the potential impact of the alarm and corrective action to remedy. |
| 1.3.6.1.4.1.37963.6.3.1.2.16 | ScalaralarmAdditionalInfo | accessible-for-notify | current | It contain semi-colon separated name/value pairs additional information. |
| 1.3.6.1.4.1.37963.6.3.1.2.17 | ScalaralarmTrapOID | accessible-for-notify | current | It is used to indicate Trap OID information. |
| 1.3.6.1.4.1.37963.6.3.1.2.18 | ScalarelementHostName | accessible-for-notify | current | Includes information about the host name of the element. |
| 1.3.6.1.4.1.37963.6.3.1.3 | NodetemsNorthBoundNotifications | |||
| 1.3.6.1.4.1.37963.6.3.1.3.1 | NotificationnetworkElementNotReachable | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever a managed network element turns unreachable (ICMP). | |
| 1.3.6.1.4.1.37963.6.3.1.3.2 | NotificationnetworkElementNotManageable | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever a managed network element is reachable via ICMP but not reachable via the … | |
| 1.3.6.1.4.1.37963.6.3.1.3.3 | NotificationnetworkElementManageable | current | Management Server will send this notification to its NB Clients (NMS / OSS) to clear the not manageable events raised previously. | |
| 1.3.6.1.4.1.37963.6.3.1.3.4 | NotificationunSupportedNetworkElementVersion | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever it encounters / discovers a Network element running an Unsupported softwar… | |
| 1.3.6.1.4.1.37963.6.3.1.3.5 | NotificationcliLoginFailed | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever it could not login to the CLI (or TL1) session of the Network Element usin… | |
| 1.3.6.1.4.1.37963.6.3.1.3.6 | NotificationalarmEmailNotificationFailure | current | Management Server will send this notification to its NB Clients (NMS / OSS) upon its Failure to send the E-Mail Notification to NB Clients registered for E-Mai… | |
| 1.3.6.1.4.1.37963.6.3.1.3.7 | NotificationdataCollectionFailure | current | Indicates a Failure during Data Collection. NB managers can either ignore it (or) log-it. | |
| 1.3.6.1.4.1.37963.6.3.1.3.8 | NotificationtemsServerPerfMetricCriticalTCA | current | Management Server will send this notification to its NB Clients (NMS / OSS) to report a Critical Threshold Crossing Alert, whenever the Critical Threshold limi… | |
| 1.3.6.1.4.1.37963.6.3.1.3.9 | NotificationtemsServerPerfMetricMajorTCA | current | Management Server will send this notification to its NB Clients (NMS / OSS) to report a Major Threshold Crossing Alert, whenever the Major Threshold limit is c… | |
| 1.3.6.1.4.1.37963.6.3.1.3.10 | NotificationtemsServerPerfMetricMinorTCA | current | Management Server will send this notification to its NB Clients (NMS / OSS) to report a Minor Threshold Crossing Alert, whenever the Minor Threshold limit is c… | |
| 1.3.6.1.4.1.37963.6.3.1.3.11 | NotificationtemsServerPerfMetricClearTCA | current | Management Server will send this notification to its NB Clients (NMS / OSS) to Clear the previously raised Critical / Major / Minor TCA for this Performance Me… | |
| 1.3.6.1.4.1.37963.6.3.1.3.12 | NotificationalarmFromNetworkElement | current | Management Server will send this notification to its NB Clients (NMS / OSS) to report an Alarm Raised due to the occurrence of a trap from the Network Element.… | |
| 1.3.6.1.4.1.37963.6.3.1.3.13 | NotificationhotStandbyTakesOver | deprecated | Indicates a Switchover of the Management server from primary to Standby Server. Note: This alarm will be triggered only when the Management Server is deployed … | |
| 1.3.6.1.4.1.37963.6.3.1.3.14 | NotificationprimaryServerisRestored | deprecated | Indicates that the Primary Management Server has been restored back in Service. Note: This alarm will be triggered only when the Management Server is deployed … | |
| 1.3.6.1.4.1.37963.6.3.1.3.15 | NotificationalarmfromElementManagementSystem | current | Management Server will send this notification to its NB Clients (NMS / OSS) to report an Alarm Raised due to the occurence of a trap from the Network Managemen… | |
| 1.3.6.1.4.1.37963.6.3.1.3.16 | NotificationgeoRedundancyGroupMismatch | current | Management server will send this notification to its NB clients (NMS / OSS) when it detects mismatch information from EMS, active and standby network element T… | |
| 1.3.6.1.4.1.37963.6.3.1.3.17 | NotificationvnfScaleKpiMonitorAlarm | current | Dynamic VM capacity management KPI monitoring alarms. Source is cluster[vclusterId]/<KPIName> where KPIName can be DCMSession, WSMSession, ASMConn, ASMThruput.… | |
| 1.3.6.1.4.1.37963.6.3.1.3.18 | NotificationvnfScaleOutAlarm | current | Generated when VM scale out operation fails Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL. The networkElementIpAddress attribute is po… | |
| 1.3.6.1.4.1.37963.6.3.1.3.19 | NotificationvnfScaleInAlarm | current | Generated when VM scale in operation fails Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL. The networkElementIpAddress attribute is pop… | |
| 1.3.6.1.4.1.37963.6.3.1.3.20 | NotificationemsClusterStatusChangeNotification | current | Management Server will send this notification to its NB Clients (NMS / OSS) upon its detection of cluster status change | |
| 1.3.6.1.4.1.37963.6.3.1.3.21 | NotificationalarmFromVCenter | current | Management Server will send this notification to its NB Clients (NMS / OSS) to report an Alarm Raised due to the occurence of a trap from VCenter Server | |
| 1.3.6.1.4.1.37963.6.3.1.3.22 | NotificationcliLoginSuccess | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever it could be login to the CLI (or TL1) session of the Network Element using… | |
| 1.3.6.1.4.1.37963.6.3.1.3.23 | NotificationcliTemplateConfigFailed | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever cli template configuration failed. | |
| 1.3.6.1.4.1.37963.6.3.1.3.24 | NotificationcliTemplateConfigSuccess | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever cli template configuration succeeds. | |
| 1.3.6.1.4.1.37963.6.3.1.3.25 | NotificationalarmtriggeredCliTemplateConfigFailed | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever alarm triggered cli template configuration failed. | |
| 1.3.6.1.4.1.37963.6.3.1.3.26 | NotificationalarmtriggeredCliTemplateConfigSuccess | current | Management Server will send this notification to its NB Clients (NMS / OSS) whenever alarm triggered cli template configuration succeeds. | |
| 1.3.6.1.4.1.37963.6.3.1.3.27 | NotificationalarmSnmpNotificationFailure | current | Management Server will send this notification to its NB Clients (NMS / OSS) upon its Failure to forward the trap to NB Clients registered for Trap Forwarding. | |
| 1.3.6.1.4.1.37963.6.3.1.3.28 | NotificationmasterSlaveStandbyNodeDown | current | Management Server will send this notification to its NB Clients (NMS / OSS) to reports that in cluster topology standby node moved to down state. | |
| 1.3.6.1.4.1.37963.6.3.1.3.29 | NotificationmasterSlaveStandbyNodeUp | current | Management Server will send this notification to its NB Clients (NMS / OSS) to reports that in cluster topology standby node moved to up state. | |
| 1.3.6.1.4.1.37963.6.3.1.3.31 | NotificationNBHeartBeat | current | Management Server will send this notification to its INFORM supported NB Clients to verify the NB client alive status. | |
| 1.3.6.1.4.1.37963.6.3.1.3.32 | NotificationnetworkElementAutoUnmanage | current | Device has been automatically unmanaged due to authentication failure. | |
| 1.3.6.1.4.1.37963.6.3.1.3.33 | NotificationnetworkElementManage | current | Device has been managed successfully. | |
| 1.3.6.1.4.1.37963.6.3.1.3.34 | NotificationCUPSConfigurationMismatch | current | CUPS Configuration mismatch found. | |
| 1.3.6.1.4.1.37963.6.3.1.3.35 | NotificationCUPSConfigurationMatch | current | CUPS Configuration mismatch cleared. | |
| 1.3.6.1.4.1.37963.6.3.1.3.36 | NotificationCUPSGroupCreationFailed | current | CUPS Group Creation Failed. Manually remove the config from CPlane. |