ALTIGA-HARDWARE-STATS-MIB
71 objects
The Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in this document: CPU: Central Processing Unit MB: Megabyte MIB: Management Information Base PS: Power Supply RPM: Revolutions Per Minute SEP: Scalable Encryption Processor WAN: Wide Area Network
Imported Objects
| ALTIGA-GLOBAL-REG | alHardwareMibModule |
| ALTIGA-MIB | alHardwareGroup alStatsHardware |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 MODULE-IDENTITY OBJECT-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3076.1.1.27.2 | IdentityaltigaHardwareStatsMibModule | The Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in th… | ||
| 1.3.6.1.4.1.3076.1.1.27.2.1 | NodealtigaHardwareStatsMibConformance | |||
| 1.3.6.1.4.1.3076.1.1.27.2.1.1 | NodealtigaHardwareStatsMibCompliances | |||
| 1.3.6.1.4.1.3076.1.1.27.2.1.1.1 | CompliancealtigaHardwareStatsMibCompliance | current | The compliance statement for agents which implement the Altiga Hardware Statistics MIB. | |
| 1.3.6.1.4.1.3076.2.1.1.1.22.2 | GroupaltigaHardwareStatsGroup | current | The objects for Hardware statistics. | |
| 1.3.6.1.4.1.3076.2.1.2.22.1 | NodealStatsHardwareGlobal | |||
| 1.3.6.1.4.1.3076.2.1.2.22.1.1 | ScalaralHardwareCpuVoltage | read-only | current | The current CPU voltage in centivolts. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.2 | ScalaralHardwareCpuVoltageAlarm | read-only | current | The alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.3 | ScalaralHardwareCpuVoltageCount | read-only | current | The number of alarm events for CPU voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.4 | ScalaralHardwareCpuVoltageTime | read-only | current | The sysUptime at the time of the last change of alarm status for CPU voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.5 | ScalaralHardwarePs1Voltage3v | read-only | current | The current 3V voltage of Power Supply 1 in centivolts. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.6 | ScalaralHardwarePs1Voltage3vAlarm | read-only | current | The alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.7 | ScalaralHardwarePs1Voltage3vCount | read-only | current | The number of alarm events for PS1 3v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.8 | ScalaralHardwarePs1Voltage3vTime | read-only | current | The sysUptime at the time of the last change of alarm status for PS1 3v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.9 | ScalaralHardwarePs1Voltage5v | read-only | current | The current 5V voltage of Power Supply 1 in centivolts. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.10 | ScalaralHardwarePs1Voltage5vAlarm | read-only | current | The alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.11 | ScalaralHardwarePs1Voltage5vCount | read-only | current | The number of alarm events for PS1 5v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.12 | ScalaralHardwarePs1Voltage5vTime | read-only | current | The sysUptime at the time of the last change of alarm status for PS1 5v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.13 | ScalaralHardwarePs2Voltage3v | read-only | current | The current 3V voltage of Power Supply 2 in centivolts. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.14 | ScalaralHardwarePs2Voltage3vAlarm | read-only | current | The alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.15 | ScalaralHardwarePs2Voltage3vCount | read-only | current | The number of alarm events for PS2 3v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.16 | ScalaralHardwarePs2Voltage3vTime | read-only | current | The sysUptime at the time of the last change of alarm status for PS2 3v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.17 | ScalaralHardwarePs2Voltage5v | read-only | current | The current 5V voltage of Power Supply 2 in centivolts. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.18 | ScalaralHardwarePs2Voltage5vAlarm | read-only | current | The alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.19 | ScalaralHardwarePs2Voltage5vCount | read-only | current | The number of alarm events for PS2 5v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.20 | ScalaralHardwarePs2Voltage5vTime | read-only | current | The sysUptime at the time of the last change of alarm status for PS2 5v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.21 | ScalaralHardwareBoardVoltage3v | read-only | current | The current 3V voltage of the mainboard in centivolts. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.22 | ScalaralHardwareBoardVoltage3vAlarm | read-only | current | The alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.23 | ScalaralHardwareBoardVoltage3vCount | read-only | current | The number of alarm events for the mainboard 3v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.24 | ScalaralHardwareBoardVoltage3vTime | read-only | current | The sysUptime at the time of the last change of alarm status for the mainboard 3v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.25 | ScalaralHardwareBoardVoltage5v | read-only | current | The current 5V voltage of the mainboard in centivolts. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.26 | ScalaralHardwareBoardVoltage5vAlarm | read-only | current | The alarm status for the mainboard 5v voltage. This alarm will fired when the 5v mainboard voltage is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.27 | ScalaralHardwareBoardVoltage5vCount | read-only | current | The number of alarm events for the mainboard 5v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.28 | ScalaralHardwareBoardVoltage5vTime | read-only | current | The sysUptime at the time of the last change of alarm status for the mainboard 5v voltage. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.29 | ScalaralHardwareCpuTemp | read-only | current | The current CPU temperature in degrees C. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.30 | ScalaralHardwareCpuTempAlarm | read-only | current | The alarm status for the CPU temperature. This alarm will fired when the CPU temperature is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.31 | ScalaralHardwareCpuTempCount | read-only | current | The number of alarm events for the CPU temperature. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.32 | ScalaralHardwareCpuTempTime | read-only | current | The sysUptime at the time of the last change of alarm status for the CPU temperature. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.33 | ScalaralHardwareCageTemp | read-only | current | The current cage temperature in degrees C. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.34 | ScalaralHardwareCageTempAlarm | read-only | current | The alarm status for the cage temperature. This alarm will fired when the cage temperature is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.35 | ScalaralHardwareCageTempCount | read-only | current | The number of alarm events for the cage temperature. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.36 | ScalaralHardwareCageTempTime | read-only | current | The sysUptime at the time of the last change of alarm status for the cage temperature. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.37 | ScalaralHardwareFan1Rpm | read-only | current | The current speed of fan 1 in RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.38 | ScalaralHardwareFan1RpmAlarm | read-only | current | The alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.39 | ScalaralHardwareFan1RpmCount | read-only | current | The number of alarm events for fan 1 RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.40 | ScalaralHardwareFan1RpmTime | read-only | current | The sysUptime at the time of the last change of alarm status for fan 1 RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.41 | ScalaralHardwareFan2Rpm | read-only | current | The current speed of fan 2 in RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.42 | ScalaralHardwareFan2RpmAlarm | read-only | current | The alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.43 | ScalaralHardwareFan2RpmCount | read-only | current | The number of alarm events for fan 2 RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.44 | ScalaralHardwareFan2RpmTime | read-only | current | The sysUptime at the time of the last change of alarm status for fan 2 RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.45 | ScalaralHardwareFan3Rpm | read-only | current | The current speed of fan 3 in RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.46 | ScalaralHardwareFan3RpmAlarm | read-only | current | The alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM is detected out of configured range. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.47 | ScalaralHardwareFan3RpmCount | read-only | current | The number of alarm events for fan 3 RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.48 | ScalaralHardwareFan3RpmTime | read-only | current | The sysUptime at the time of the last change of alarm status for fan 3 RPM. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.49 | ScalaralHardwarePs1Type | read-only | current | The type of power supply for Power Supply slot 1. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.50 | ScalaralHardwarePs2Type | read-only | current | The type of power supply for Power Supply slot 2. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.51 | ScalaralHardwareSlot1Card | read-only | current | The type of card in slot 1. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.52 | ScalaralHardwareSlot2Card | read-only | current | The type of card in slot 2. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.53 | ScalaralHardwareSlot3Card | read-only | current | The type of card in slot 3. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.54 | ScalaralHardwareSlot4Card | read-only | current | The type of card in slot 4. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.55 | ScalaralHardwareSlot1Operational | read-only | current | The operational status of card in slot 1. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.56 | ScalaralHardwareSlot2Operational | read-only | current | The operational status of card in slot 2. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.57 | ScalaralHardwareSlot3Operational | read-only | current | The operational status of card in slot 3. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.58 | ScalaralHardwareSlot4Operational | read-only | current | The operational status of card in slot 4. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.59 | ScalaralHardwareRamSize | read-only | current | The amount of memory, in MB on the concentrator. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.60 | ScalaralHardwareChassis | read-only | current | The type of VPN Concentrator this is. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.61 | ScalaralHardwareCpuVoltageNominal | read-only | current | The nominal CPU voltage in centivolts for the concentrator. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.62 | ScalaralHardwareClientEthPrivSwitch | read-only | current | Whether or not the 3002 Hardware Client has an Ethernet Switch for the private interface. |
| 1.3.6.1.4.1.3076.2.1.2.22.1.63 | ScalaralHardwareSerialNumber | read-only | current | Unit serial number. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| ConcentratorCard | INTEGER { none(1), sep(2), dualT1Wan(3), sepE(4) } | current | Concentrator Card Type. |
| ConcentratorType | INTEGER { cxx(1), c5(2), c1(3) } | current | Concentrator Type indicates the chassis type. |