ALTIGA-HARDWARE-STATS-MIB

71 objects
The Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in this document: CPU: Central Processing Unit MB: Megabyte MIB: Management Information Base PS: Power Supply RPM: Revolutions Per Minute SEP: Scalable Encryption Processor WAN: Wide Area Network
OIDNameAccessStatusDescription
1.3.6.1.4.1.3076.1.1.27.2IdentityaltigaHardwareStatsMibModuleThe Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in th…
1.3.6.1.4.1.3076.1.1.27.2.1NodealtigaHardwareStatsMibConformance
1.3.6.1.4.1.3076.1.1.27.2.1.1NodealtigaHardwareStatsMibCompliances
1.3.6.1.4.1.3076.1.1.27.2.1.1.1CompliancealtigaHardwareStatsMibCompliancecurrentThe compliance statement for agents which implement the Altiga Hardware Statistics MIB.
1.3.6.1.4.1.3076.2.1.1.1.22.2GroupaltigaHardwareStatsGroupcurrentThe objects for Hardware statistics.
1.3.6.1.4.1.3076.2.1.2.22.1NodealStatsHardwareGlobal
1.3.6.1.4.1.3076.2.1.2.22.1.1ScalaralHardwareCpuVoltageread-onlycurrentThe current CPU voltage in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.2ScalaralHardwareCpuVoltageAlarmread-onlycurrentThe alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.3ScalaralHardwareCpuVoltageCountread-onlycurrentThe number of alarm events for CPU voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.4ScalaralHardwareCpuVoltageTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for CPU voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.5ScalaralHardwarePs1Voltage3vread-onlycurrentThe current 3V voltage of Power Supply 1 in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.6ScalaralHardwarePs1Voltage3vAlarmread-onlycurrentThe alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.7ScalaralHardwarePs1Voltage3vCountread-onlycurrentThe number of alarm events for PS1 3v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.8ScalaralHardwarePs1Voltage3vTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for PS1 3v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.9ScalaralHardwarePs1Voltage5vread-onlycurrentThe current 5V voltage of Power Supply 1 in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.10ScalaralHardwarePs1Voltage5vAlarmread-onlycurrentThe alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.11ScalaralHardwarePs1Voltage5vCountread-onlycurrentThe number of alarm events for PS1 5v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.12ScalaralHardwarePs1Voltage5vTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for PS1 5v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.13ScalaralHardwarePs2Voltage3vread-onlycurrentThe current 3V voltage of Power Supply 2 in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.14ScalaralHardwarePs2Voltage3vAlarmread-onlycurrentThe alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.15ScalaralHardwarePs2Voltage3vCountread-onlycurrentThe number of alarm events for PS2 3v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.16ScalaralHardwarePs2Voltage3vTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for PS2 3v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.17ScalaralHardwarePs2Voltage5vread-onlycurrentThe current 5V voltage of Power Supply 2 in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.18ScalaralHardwarePs2Voltage5vAlarmread-onlycurrentThe alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.19ScalaralHardwarePs2Voltage5vCountread-onlycurrentThe number of alarm events for PS2 5v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.20ScalaralHardwarePs2Voltage5vTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for PS2 5v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.21ScalaralHardwareBoardVoltage3vread-onlycurrentThe current 3V voltage of the mainboard in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.22ScalaralHardwareBoardVoltage3vAlarmread-onlycurrentThe alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.23ScalaralHardwareBoardVoltage3vCountread-onlycurrentThe number of alarm events for the mainboard 3v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.24ScalaralHardwareBoardVoltage3vTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for the mainboard 3v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.25ScalaralHardwareBoardVoltage5vread-onlycurrentThe current 5V voltage of the mainboard in centivolts.
1.3.6.1.4.1.3076.2.1.2.22.1.26ScalaralHardwareBoardVoltage5vAlarmread-onlycurrentThe alarm status for the mainboard 5v voltage. This alarm will fired when the 5v mainboard voltage is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.27ScalaralHardwareBoardVoltage5vCountread-onlycurrentThe number of alarm events for the mainboard 5v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.28ScalaralHardwareBoardVoltage5vTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for the mainboard 5v voltage.
1.3.6.1.4.1.3076.2.1.2.22.1.29ScalaralHardwareCpuTempread-onlycurrentThe current CPU temperature in degrees C.
1.3.6.1.4.1.3076.2.1.2.22.1.30ScalaralHardwareCpuTempAlarmread-onlycurrentThe alarm status for the CPU temperature. This alarm will fired when the CPU temperature is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.31ScalaralHardwareCpuTempCountread-onlycurrentThe number of alarm events for the CPU temperature.
1.3.6.1.4.1.3076.2.1.2.22.1.32ScalaralHardwareCpuTempTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for the CPU temperature.
1.3.6.1.4.1.3076.2.1.2.22.1.33ScalaralHardwareCageTempread-onlycurrentThe current cage temperature in degrees C.
1.3.6.1.4.1.3076.2.1.2.22.1.34ScalaralHardwareCageTempAlarmread-onlycurrentThe alarm status for the cage temperature. This alarm will fired when the cage temperature is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.35ScalaralHardwareCageTempCountread-onlycurrentThe number of alarm events for the cage temperature.
1.3.6.1.4.1.3076.2.1.2.22.1.36ScalaralHardwareCageTempTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for the cage temperature.
1.3.6.1.4.1.3076.2.1.2.22.1.37ScalaralHardwareFan1Rpmread-onlycurrentThe current speed of fan 1 in RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.38ScalaralHardwareFan1RpmAlarmread-onlycurrentThe alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.39ScalaralHardwareFan1RpmCountread-onlycurrentThe number of alarm events for fan 1 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.40ScalaralHardwareFan1RpmTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for fan 1 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.41ScalaralHardwareFan2Rpmread-onlycurrentThe current speed of fan 2 in RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.42ScalaralHardwareFan2RpmAlarmread-onlycurrentThe alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.43ScalaralHardwareFan2RpmCountread-onlycurrentThe number of alarm events for fan 2 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.44ScalaralHardwareFan2RpmTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for fan 2 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.45ScalaralHardwareFan3Rpmread-onlycurrentThe current speed of fan 3 in RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.46ScalaralHardwareFan3RpmAlarmread-onlycurrentThe alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM is detected out of configured range.
1.3.6.1.4.1.3076.2.1.2.22.1.47ScalaralHardwareFan3RpmCountread-onlycurrentThe number of alarm events for fan 3 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.48ScalaralHardwareFan3RpmTimeread-onlycurrentThe sysUptime at the time of the last change of alarm status for fan 3 RPM.
1.3.6.1.4.1.3076.2.1.2.22.1.49ScalaralHardwarePs1Typeread-onlycurrentThe type of power supply for Power Supply slot 1.
1.3.6.1.4.1.3076.2.1.2.22.1.50ScalaralHardwarePs2Typeread-onlycurrentThe type of power supply for Power Supply slot 2.
1.3.6.1.4.1.3076.2.1.2.22.1.51ScalaralHardwareSlot1Cardread-onlycurrentThe type of card in slot 1.
1.3.6.1.4.1.3076.2.1.2.22.1.52ScalaralHardwareSlot2Cardread-onlycurrentThe type of card in slot 2.
1.3.6.1.4.1.3076.2.1.2.22.1.53ScalaralHardwareSlot3Cardread-onlycurrentThe type of card in slot 3.
1.3.6.1.4.1.3076.2.1.2.22.1.54ScalaralHardwareSlot4Cardread-onlycurrentThe type of card in slot 4.
1.3.6.1.4.1.3076.2.1.2.22.1.55ScalaralHardwareSlot1Operationalread-onlycurrentThe operational status of card in slot 1.
1.3.6.1.4.1.3076.2.1.2.22.1.56ScalaralHardwareSlot2Operationalread-onlycurrentThe operational status of card in slot 2.
1.3.6.1.4.1.3076.2.1.2.22.1.57ScalaralHardwareSlot3Operationalread-onlycurrentThe operational status of card in slot 3.
1.3.6.1.4.1.3076.2.1.2.22.1.58ScalaralHardwareSlot4Operationalread-onlycurrentThe operational status of card in slot 4.
1.3.6.1.4.1.3076.2.1.2.22.1.59ScalaralHardwareRamSizeread-onlycurrentThe amount of memory, in MB on the concentrator.
1.3.6.1.4.1.3076.2.1.2.22.1.60ScalaralHardwareChassisread-onlycurrentThe type of VPN Concentrator this is.
1.3.6.1.4.1.3076.2.1.2.22.1.61ScalaralHardwareCpuVoltageNominalread-onlycurrentThe nominal CPU voltage in centivolts for the concentrator.
1.3.6.1.4.1.3076.2.1.2.22.1.62ScalaralHardwareClientEthPrivSwitchread-onlycurrentWhether or not the 3002 Hardware Client has an Ethernet Switch for the private interface.
1.3.6.1.4.1.3076.2.1.2.22.1.63ScalaralHardwareSerialNumberread-onlycurrentUnit serial number.
Type Definitions
NameSyntaxStatusDescription
ConcentratorCardINTEGER { none(1), sep(2), dualT1Wan(3), sepE(4) }currentConcentrator Card Type.
ConcentratorTypeINTEGER { cxx(1), c5(2), c1(3) }currentConcentrator Type indicates the chassis type.