MIB Viewer

ALU-POWER-ETHERNET-MIB

51 objects
The MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powered Ethernet (DTE Power via MDI) standard. The following terms are used throughout this MIB module. For complete formal definitions, the IEEE 802.3 standards should be consulted wherever possible: Group - A recommended, but optional, entity defined by the IEEE 802.3 management standard, in order to support a modular numbering scheme. The classical example allows an implementor to represent field-replaceable units as groups of ports, with the port numbering matching the modular hardware implementation. Port - This entity identifies the port within the group for which this entry contains information. The numbering scheme for ports is implementation specific.
Imported Objects
ALCATEL-IND1-BASEsoftentIND1InLinePower
IF-MIBInterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMI-- MODULE-IDENTITY Counter32 Gauge32 Integer32 mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCTruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.6486.800.1.2.1.27.999IdentitypowerEthernetMIBThe MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powered Ethernet (DTE Power via MDI) …
1.3.6.1.4.1.6486.800.1.2.1.27.999.0NodepethNotifications
1.3.6.1.4.1.6486.800.1.2.1.27.999.0.1NotificationpethPsePortOnOffNotificationcurrentThis Notification indicates if Pse Port is delivering or not power to the PD. This Notification SHOULD be sent on every status change except in the searching m…
1.3.6.1.4.1.6486.800.1.2.1.27.999.0.2NotificationpethPsePortPowerMaintenanceStatusNotificationcurrentThis Notification indicates a Port Change Status and it SHOULD be sent on every status change.
1.3.6.1.4.1.6486.800.1.2.1.27.999.0.4NotificationpethMainPowerUsageOnNotificationcurrentThis Notification indicate PSE Threshold usage indication is on, the usage power is above the threshold.
1.3.6.1.4.1.6486.800.1.2.1.27.999.0.5NotificationpethMainPowerUsageOffNotificationcurrentThis Notification indicate PSE Threshold usage indication off, the usage power is below the threshold.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1NodepethObjects
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1TablepethPsePortTablenot-accessiblecurrentA table of objects that display and control the power characteristics power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemente…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1RowpethPsePortEntrynot-accessiblecurrentA set of objects that display and control the power characteristics of a power Ethernet PSE port.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.1ColumnpethPsePortGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and …
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.2ColumnpethPsePortIndexnot-accessiblecurrentThis variable uniquely identifies the power Ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entry is connected.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.3ColumnpethPsePortAdminEnableread-writecurrentEnables power supply on this port. Setting this object at a value enable(1) enables power and detection mechanism for this port. Setting this object at a value…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.4ColumnpethPsePortPowerPairsControlAbilityread-onlycurrentDescribes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate that the device has the capabi…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.5ColumnpethPsePortPowerPairsread-writecurrentDescribes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the sign…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.6ColumnpethPsePortPowerDetectionControlread-writecurrentControls the power detection mechanism of the port. Setting the value auto(1) enables the power detection mechanism of the port. Setting the value test(2) puts…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.7ColumnpethPsePortDetectionStatusread-onlycurrentDescribes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state IDLE A value of searchi…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.8ColumnpethPsePortPowerPriorityread-writecurrentThis object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used b…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.10ColumnpethPsePortPowerMaintenanceStatusread-onlycurrentThe value ok(1) indicates the Power Maintenance Signature is present and the overcurrent condition has not been detected. The value overCurrent (2) indicates a…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.11ColumnpethPsePortMPSAbsentCounterread-onlycurrentCounts the number of times that the pethPsePortPowerMaintenanceStatus attribute changes from any value to the value mPSAbsent(3).
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.12ColumnpethPsePortOverCurrentCounterread-onlycurrentCounts the number of times that the aPSEPowerCurrentStatus attribute changes from any value to the value overCurrent(2).
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.13ColumnpethPsePortTyperead-writecurrentA manager will set the value of this variable to a value that indicates the type of the device that is connected to theport. This value can be the result of th…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.1.1.14ColumnpethPsePortPowerClassificationsread-onlycurrentClassification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN acce…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2TablepethPdPortTablenot-accessiblecurrentA table of objects that display and control the power characteristics power Ethernet ports on a Powered Device(PD) device. This group will be implemented in ma…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2.1RowpethPdPortEntrynot-accessiblecurrentA set of objects that display and control the power characteristics of a Powered Device port.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2.1.1ColumnpethPdPortIndexnot-accessiblecurrentAn index value that uniquely identifies an interface to a PD device. The interface identified by a particular value of this index is the same interface as iden…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.2.1.2ColumnpethPdPortAdminEnableread-writecurrentThis value identifies the operational state of the PD functions. An interface which can provide the PD functions will be enabled to do so when this attribute h…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3NodepethMainPseObjects
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1TablepethMainPseTablenot-accessiblecurrentA table of objects that display and control the Main power on a PSE device. Example - an Ethernet switch midspan device can control an Ethnternet port and the …
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1RowpethMainPseEntrynot-accessiblecurrentA set of objects that display and control the Main power of a PSE.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.1ColumnpethMainPseGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group to which power Ethernet PSE is connected.Group means (box in the stack, module in a rack) and the value 1 MUST be u…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.2ColumnpethMainPsePowerread-onlycurrentThe nominal power of the PSE expressed in Watts.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.3ColumnpethMainPseOperStatusread-onlycurrentThe operational status of the main PSE.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.4ColumnpethMainPseConsumptionPowerread-onlycurrentMeasured usage power expressed in Watts.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.3.1.1.7ColumnpethMainPseUsageThresholdread-writecurrentThe usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4NodepethNotificationControl
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4.1TablepethNotificationControlTablenot-accessiblecurrentA table of objects that display and control the Notification on a PSE device.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4.1.1RowpethNotificationControlEntrynot-accessiblecurrentA set of objects that control the Notification events.
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4.1.1.1ColumnpethNotificationControlGroupIndexnot-accessiblecurrentThis variable uniquely identifies the group. Group means box in the stack, module in a rack and it is RECOMENDED that the value 1 be used for non-modular devic…
1.3.6.1.4.1.6486.800.1.2.1.27.999.1.4.1.1.2ColumnpethNotificationControlEnableread-writecurrentEnable Notification from Agent
1.3.6.1.4.1.6486.800.1.2.1.27.999.2NodepethConformance
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.1NodepethCompliances
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.1.1CompliancepethCompliancecurrentDescribes the requirements for conformance to the Power Ethernet MIB.
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.1.2CompliancepethPseCompliancecurrentDescribes the requirements for conformance to the PSE and MID- Span.
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.1.3CompliancepethPdCompliancecurrentDescribes the requirements for conformance to the PD.
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.1.4GrouppethPsePortNotificationGroupcurrentPse Notification indications
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.1.5GrouppethMainPowerNotificationGroupcurrentPse Notification indications
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.2NodepethGroups
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.2.1GrouppethPsePortGroupcurrentThe pethPsePortGroup is mandatory for systems which implement PSE ports.
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.2.2GrouppethPdPortGroupcurrentThe pethPdPortGroup is mandatory for systems which implement PD Ports.
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.2.3GrouppethMainPseGroupcurrentMain PSE Objects.
1.3.6.1.4.1.6486.800.1.2.1.27.999.2.2.4GrouppethNotificationControlGroupcurrentNotification Control Objects.