MIB Viewer

APNL-MODULAR-PDU-MIB

89 objects
This MIB module defines the modular PDU version of AP Nederland.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.29640IdentityapNederlandThis MIB module defines the modular PDU version of AP Nederland.
1.3.6.1.4.1.29640.1NodeapnlDirectory
1.3.6.1.4.1.29640.2NodeapnlMib
1.3.6.1.4.1.29640.3NodeapnlTmp
1.3.6.1.4.1.29640.4NodeapnlModules
1.3.6.1.4.1.29640.4.1Nodecm
1.3.6.1.4.1.29640.4.2NodecmTraps
1.3.6.1.4.1.29640.4.3Nodepdu
1.3.6.1.4.1.29640.4.3.1ScalarpduTyperead-onlycurrentType of the Pdu. PduModular (0) Modulaire OEC2 PDU communication through SNMPV3, MOD-BUS or AP-BUS in emulation mode. PduGateway1 (1) Gateway to connect OEC1 p…
1.3.6.1.4.1.29640.4.3.2ScalarpduProductIdentifierread-onlycurrentUnique serial number to identify a pdu, the number is between 1 and 65535.
1.3.6.1.4.1.29640.4.3.3ScalarpduSerialNumberread-onlycurrentPDU onboard Serial Number.
1.3.6.1.4.1.29640.4.3.4ScalarpduStatusread-onlycurrentStatus of the Pdu. pduBusy (0) Indicates that an admin command is in progress. pduReady (1) The execution of an admin command was successfull. pduAlarm (2) Thi…
1.3.6.1.4.1.29640.4.3.5ScalarpduPowerread-onlycurrentThe total measured pdu power in Kilo Watt's*Hour.
1.3.6.1.4.1.29640.4.3.6ScalarpduPowerL1read-onlycurrentThe total measured pdu power in Kilo Watt's*Hour for phase 1.
1.3.6.1.4.1.29640.4.3.7ScalarpduPowerL2read-onlycurrentThe total measured pdu power in Kilo Watt's*Hour for phase 2.
1.3.6.1.4.1.29640.4.3.8ScalarpduPowerL3read-onlycurrentThe total measured pdu power in Kilo Watt's*Hour for phase 3.
1.3.6.1.4.1.29640.4.3.9ScalarpduKvarread-onlycurrentThe total Reactive Power of the pdu. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.
1.3.6.1.4.1.29640.4.3.10ScalarpduKvarL1read-onlycurrentThe total Reactive Power of the pdu for phase 1. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.
1.3.6.1.4.1.29640.4.3.11ScalarpduKvarL2read-onlycurrentThe total Reactive Power of the pdu for phase 2. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.
1.3.6.1.4.1.29640.4.3.12ScalarpduKvarL3read-onlycurrentThe total Reactive Power of the pdu for phase 3. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.
1.3.6.1.4.1.29640.4.3.13ScalarpdulAcurrentread-onlycurrentThe total measured ac current for the pdu (in 1/10th Amperes) .
1.3.6.1.4.1.29640.4.3.14ScalarpduAcurrentL1read-onlycurrentThe total measured ac current for phase 1 (in 1/10th Amperes).
1.3.6.1.4.1.29640.4.3.15ScalarpduAcurrentL2read-onlycurrentThe total measured ac current for phase 2 (in 1/10th Amperes).
1.3.6.1.4.1.29640.4.3.16ScalarpduAcurrentL3read-onlycurrentThe total measured ac current for phase 3 (in 1/10th Amperes).
1.3.6.1.4.1.29640.4.3.17ScalarpduCurIpAddressread-onlycurrentThe current PDU IPv4 Address by which TCP/IP access is available.
1.3.6.1.4.1.29640.4.3.18ScalarpduCurSubNetMaskread-onlycurrentThe current PDU IPv4 Subnet Mask used by the Ipstack (e.g: 255.255.255.0).
1.3.6.1.4.1.29640.4.3.19ScalarpduCurDefGwAddressread-onlycurrentThe current PDU IPv4 default gateway address used by the Ipstack (e.g: 192.168.1.1).
1.3.6.1.4.1.29640.4.3.20ScalarpduNumberOfNodesread-onlycurrentNumber of items in the node table.
1.3.6.1.4.1.29640.4.3.21ScalarpduNumberOfSensorsread-onlycurrentNumber of items in the sensor table.
1.3.6.1.4.1.29640.4.3.22ScalarpduSoftwareVersionread-onlycurrentPDU software version number.
1.3.6.1.4.1.29640.4.3.23ScalarpduFirmwareVersionread-onlycurrentPDU firmware version number.
1.3.6.1.4.1.29640.4.3.24ScalarpduBusProtocolread-onlycurrentSelected protocol used on the external bus of the pdu. AP-BUS (0) Protocol used by OEC1 products or by OEC2 products in emulation mode. MOD-BUS (1) Protocol us…
1.3.6.1.4.1.29640.4.3.25ScalarpduAdminCommandread-writecurrentPDU admin management Commands: noOp (0) No operation. rebootPdu (1) Reboot the PDU (to execute new settings). rediscover (2) Not supported. updateSofware (3) N…
1.3.6.1.4.1.29640.4.3.26ScalarpduStartupIpAddressread-writecurrentNot supported.
1.3.6.1.4.1.29640.4.3.27ScalarpduStartupSubNetMaskread-writecurrentNot supported.
1.3.6.1.4.1.29640.4.3.28ScalarpduStartupDefGwAddressread-writecurrentNot supported.
1.3.6.1.4.1.29640.4.3.29ScalarpduRealTimeClockread-writecurrentPDU Real-Time Clock. Maybe set by the manager.
1.3.6.1.4.1.29640.4.3.30ScalarpduEnableFeaturesread-writecurrentArray of bits each one an specific feature within the pdu: globalWebEnabled (0) This bit enables the PDU webpages. globalUsbEnabled (1) This bit enables the US…
1.3.6.1.4.1.29640.4.3.31ScalarpduBusAddressread-writecurrentAddress used to access this PDU via the external bus. When MOD-BUS protocol is used the address is valid between 1-247. When AP-BUS protocol is used the addres…
1.3.6.1.4.1.29640.4.3.32ScalarpduNameread-writecurrentName of the PDU.
1.3.6.1.4.1.29640.4.3.33TablenodeTablenot-accessiblecurrentA table of the modules on the PDU. Each entry represents an module unit.
1.3.6.1.4.1.29640.4.3.33.1RownodeEntrynot-accessiblecurrentAn port entry in the port table.
1.3.6.1.4.1.29640.4.3.33.1.1ColumnnodeIndexnot-accessiblecurrentThe node table Index.
1.3.6.1.4.1.29640.4.3.33.1.2ColumnnodeTyperead-onlycurrentType of the node. TypeUnknown (0) Unknown node. TypePresModChar (1) PM LCD Character Module. TypePresModMono (2) PM Mono Graphics Module. TypePresModGraph (3) …
1.3.6.1.4.1.29640.4.3.33.1.3ColumnnodeOutletread-onlycurrentThe number associated with the physical outlet of the node. The special value of 0 indicates that this entry is not associated with a physical port.
1.3.6.1.4.1.29640.4.3.33.1.4ColumnnodeAlarmStatusread-onlycurrentArray of bits each one indicates an alarm activated in the alarm selector value. TrapCurrHi (0) The current is to high against the high current threshold. Trap…
1.3.6.1.4.1.29640.4.3.33.1.5ColumnnodePowerread-onlycurrentThe measured node power in Kilo Watt's*Hour.
1.3.6.1.4.1.29640.4.3.33.1.6ColumnnodeAcurrentread-onlycurrentThe measured ac current at the node (in 1/10th Amperes).
1.3.6.1.4.1.29640.4.3.33.1.7ColumnnodePeakCurrentread-onlycurrentThe measured max current since last reset of the node (in 1/10th Amperes).
1.3.6.1.4.1.29640.4.3.33.1.8ColumnnodeVoltageread-onlycurrentThe measured voltage on the node.
1.3.6.1.4.1.29640.4.3.33.1.9ColumnnodeMinVoltageread-onlycurrentThe measured minimum voltage at the node since last reset.
1.3.6.1.4.1.29640.4.3.33.1.10ColumnnodeKvarread-onlycurrentThe Reactive Power. It is the power that magnetic equipment (transformer, motor and relay) needs to produce the magnetizing flux.
1.3.6.1.4.1.29640.4.3.33.1.11ColumnnodeFrequencyread-onlycurrentThe frequency of alternating current in Hertz. e.g 50 in Europe or 60 in USA.
1.3.6.1.4.1.29640.4.3.33.1.12ColumnnodePowerFactorread-onlycurrentThe effective power facton (Cosinus Phi) in percents of the node.
1.3.6.1.4.1.29640.4.3.33.1.13ColumnnodeSwitchOperStatusread-onlycurrentThe actual operational Status of the node. Unknown (0) not known status. Off (1) switch is off. On (2) switch is on.
1.3.6.1.4.1.29640.4.3.33.1.14ColumnnodeSwitchAdminStatusread-writecurrentThe desired admin Status of the switch. Unknown (0) not known. Off (1) switch is off. On (2) switch is on.
1.3.6.1.4.1.29640.4.3.33.1.15ColumnnodeCurrHiThreshread-writecurrentThe current high threshold (in 1/10th Amperes).
1.3.6.1.4.1.29640.4.3.33.1.16ColumnnodeCurrLoThreshread-writecurrentThe current low threshold (in 1/10th Amperes).
1.3.6.1.4.1.29640.4.3.33.1.17ColumnnodeVoltHiThreshread-writecurrentThe voltage high threshold.
1.3.6.1.4.1.29640.4.3.33.1.18ColumnnodeVoltLoThreshread-writecurrentThe voltage low threshold.
1.3.6.1.4.1.29640.4.3.33.1.19ColumnnodeAlarmSelectorread-writecurrentArray of bits each one controls one alarm. TrapCurrHi (0) Enable/disable the high current alarm. TrapCurrLo (1) Enable/disable the low current alarm. TrapVoltH…
1.3.6.1.4.1.29640.4.3.33.1.20ColumnnodeNameread-writecurrentThe node name. My be set by manager.
1.3.6.1.4.1.29640.4.3.33.1.21ColumnnodePhaseread-writecurrentThe measured phase of the node. Maybe assigned when not configured in production. PhaseUnknown (0). PhaseL1 (1). PhaseL2 (2). PhaseL3 (3).
1.3.6.1.4.1.29640.4.3.34TablesensorTablenot-accessiblecurrentA table of the Sensors on the PDU. Each entry represents an an Sensor unit.
1.3.6.1.4.1.29640.4.3.34.1RowsensorEntrynot-accessiblecurrentAn Sensor Entry in the Sensor table
1.3.6.1.4.1.29640.4.3.34.1.1ColumnsensorIndexnot-accessiblecurrentThe Sensor table Index.
1.3.6.1.4.1.29640.4.3.34.1.2ColumnsensorTyperead-onlycurrentSensor Typ: Measured values are used according to sensor type. Other (0) unknown sensor type. Temperature (1) . Humidity (2). Smoke (3). CO1 (4). Vibration (5)…
1.3.6.1.4.1.29640.4.3.34.1.3ColumnsensorAlarmStatusread-onlycurrentArray of bits each one indicates an alarm activated in the alarm selector value.
1.3.6.1.4.1.29640.4.3.34.1.4ColumnsensorValueread-onlycurrentThe measured value of the sensor, units are depending on sensor type.
1.3.6.1.4.1.29640.4.3.34.1.5ColumnsensorSwitchOperStatusread-onlycurrentThe actual operational Status of the switch.
1.3.6.1.4.1.29640.4.3.34.1.6ColumnsensorSwitchAdminStatusread-writecurrentThe desired admin Status of the switch.
1.3.6.1.4.1.29640.4.3.34.1.7ColumnsensorHiThreshread-writecurrentHigh threshold.
1.3.6.1.4.1.29640.4.3.34.1.8ColumnsensorLoThreshread-writecurrentLow threshold.
1.3.6.1.4.1.29640.4.3.34.1.9ColumnsensorAlarmSelectorread-writecurrentArray of bits each one controls one alarm. E.g trap, beeper etc.
1.3.6.1.4.1.29640.4.3.34.1.10ColumnsensorNameread-writecurrentThe sensor name. May be set by the manager.
1.3.6.1.4.1.29640.4.4NodepduTraps
1.3.6.1.4.1.29640.4.4.1ScalartrapTypeaccessible-for-notifycurrentAn enumation value to indicate an Alarm trap: pduPduAlarm.
1.3.6.1.4.1.29640.4.4.2ScalarpduTableTypeaccessible-for-notifycurrentThe table type.
1.3.6.1.4.1.29640.4.4.3ScalartrapTableIndexaccessible-for-notifycurrentThe index of the table entry for which the trap is issued.
1.3.6.1.4.1.29640.4.4.4ScalartrapThreshHoldTypeaccessible-for-notifycurrentThe threshold type for which the trap is made.
1.3.6.1.4.1.29640.4.4.5ScalartrapThreshHoldaccessible-for-notifycurrentThe threshold reference value.
1.3.6.1.4.1.29640.4.4.6NotificationpduVoltageAlarmcurrentVoltage alarm.
1.3.6.1.4.1.29640.4.4.7NotificationpduCurrentAlarmcurrentCurrent alaram.
1.3.6.1.4.1.29640.4.4.8NotificationpduPowerAlarmcurrentPower alarm.
1.3.6.1.4.1.29640.4.4.9NotificationsensorAlarmcurrentSensor Alarm: Temperature, Humidity or another type. The sensorType indicates the type of alarm. The sensorValue indicate the measured value.
1.3.6.1.4.1.29640.4.4.10NotificationpduSwitchAlarmcurrentNot supported.
1.3.6.1.4.1.29640.5NodeapnlTest
1.3.6.1.4.1.29640.6NodeapnlDemo
1.3.6.1.4.1.29640.7NodeapnlMIBConformance