MIB Viewer

ARRIS-C3-FPD-MIB

54 objects
This MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3
Imported Objects
ARRIS-MIBcmtsC3
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.4115.1.4.3.3IdentitycmtsC3FPDMIBThis MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3
1.3.6.1.4.1.4115.1.4.3.3.1NodedcxFPDObjects
1.3.6.1.4.1.4115.1.4.3.3.1.1TabledcxFPDMsgTablenot-accessiblecurrentTable of Front Panel LCD Messages.
1.3.6.1.4.1.4115.1.4.3.3.1.1.1RowdcxFPDMsgEntrynot-accessiblecurrent.
1.3.6.1.4.1.4115.1.4.3.3.1.1.1.1ColumndcxFPDMsgIndexnot-accessiblecurrentIndex used to order the FPD Messages.
1.3.6.1.4.1.4115.1.4.3.3.1.1.1.2ColumndcxFPDMsgStringread-writecurrentSpecifies a string that can be displayed on the front panel.
1.3.6.1.4.1.4115.1.4.3.3.1.2NodedcxFPDControlGroup
1.3.6.1.4.1.4115.1.4.3.3.1.2.1ScalardcxFPDAttachedStatusread-onlycurrentDisplays if the front panel display is attached to the Cmts or not.
1.3.6.1.4.1.4115.1.4.3.3.1.2.2ScalardcxFPDPowerStatus1read-onlycurrentSpecifies if the primary power supply is working. This is the rightmost power supply. The following values are possible: on(1) and off(2)
1.3.6.1.4.1.4115.1.4.3.3.1.2.3ScalardcxFPDPowerStatus2read-onlycurrentSpecifies if the secondary power supply is working. This is the leftmost power supply(nearest the fan tray). The following values are possible: on(1) and off(2)
1.3.6.1.4.1.4115.1.4.3.3.1.2.4ScalardcxFPDTemp1Statusread-onlycurrentSpecifies the temperature reading for the sensor on the CPU card closest to the CPU.
1.3.6.1.4.1.4115.1.4.3.3.1.2.5ScalardcxFPDTemp2Statusread-onlycurrentSpecifies the temperature reading for the sensor on the CPU card, on the right hand side.
1.3.6.1.4.1.4115.1.4.3.3.1.2.6ScalardcxFPDTemp3Statusread-onlycurrentSpecifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX4 and RX5.
1.3.6.1.4.1.4115.1.4.3.3.1.2.7ScalardcxFPDTemp4Statusread-onlycurrentSpecifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX2 and RX3.
1.3.6.1.4.1.4115.1.4.3.3.1.2.8ScalardcxFPDFan1Statusread-onlycurrentSpecifies the fan status for the fan nearest the front of the box. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when t…
1.3.6.1.4.1.4115.1.4.3.3.1.2.9ScalardcxFPDFan2Statusread-onlycurrentSpecifies the fan status for the fan 2nd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is …
1.3.6.1.4.1.4115.1.4.3.3.1.2.10ScalardcxFPDFan3Statusread-onlycurrentSpecifies the fan status for the fan 3rd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is …
1.3.6.1.4.1.4115.1.4.3.3.1.2.11ScalardcxFPDFan4Statusread-onlycurrentSpecifies the fan status for the fan 4th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is …
1.3.6.1.4.1.4115.1.4.3.3.1.2.12ScalardcxFPDFan5Statusread-onlycurrentSpecifies the fan status for the fan 5th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is …
1.3.6.1.4.1.4115.1.4.3.3.1.2.13ScalardcxFPDFan6Statusread-onlycurrentSpecifies the fan status for the fan nearest the back of the box The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the…
1.3.6.1.4.1.4115.1.4.3.3.1.2.14ScalardcxFPDFanUpperLimitread-writecurrentSpecifies the upper fan limit(Upper threshold of expected current draw)
1.3.6.1.4.1.4115.1.4.3.3.1.2.15ScalardcxFPDFanLowerLimitread-writecurrentSpecifies the lower fan limit(Lower threshold of expected current draw)
1.3.6.1.4.1.4115.1.4.3.3.1.2.16ScalardcxFPDLCDContrastread-writecurrentSpecifies the contrast level for the LCD
1.3.6.1.4.1.4115.1.4.3.3.1.2.17ScalardcxFPDLedSetStatusread-writecurrentUsed to turn on or off a Led on the front panel
1.3.6.1.4.1.4115.1.4.3.3.1.2.18ScalardcxFPDHwRevisionread-onlycurrentSpecifies the front panel h/w revision
1.3.6.1.4.1.4115.1.4.3.3.1.2.19ScalardcxFPDSwRevisionread-onlycurrentSpecifies the front panel s/w revision
1.3.6.1.4.1.4115.1.4.3.3.1.3NodedcxFPDTrapGroup
1.3.6.1.4.1.4115.1.4.3.3.1.3.1NotificationdcxFPDAttachedcurrentFront Panel Display has been attached.
1.3.6.1.4.1.4115.1.4.3.3.1.3.2NotificationdcxFPDDetachedcurrentFront Panel Display has been detached.
1.3.6.1.4.1.4115.1.4.3.3.1.3.3NotificationdcxFPDFan1FailcurrentFan nearest the front of the box failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.4NotificationdcxFPDFan1FailClrcurrentFan nearest the front of the box is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.5NotificationdcxFPDFan2FailcurrentFan 2nd from the front failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.6NotificationdcxFPDFan2FailClrcurrentFan 2nd from the front is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.7NotificationdcxFPDFan3FailcurrentFan 3rd from the front failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.8NotificationdcxFPDFan3FailClrcurrentFan 3rd from the front is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.9NotificationdcxFPDFan4FailcurrentFan 4th from the front failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.10NotificationdcxFPDFan4FailClrcurrentFan 4th from the front is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.11NotificationdcxFPDFan5FailcurrentFan 5th from the front failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.12NotificationdcxFPDFan5FailClrcurrentFan 5th from the front is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.13NotificationdcxFPDFan6FailcurrentFan nearest the back of the box failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.14NotificationdcxFPDFan6FailClrcurrentFan nearest the back of the box is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.15NotificationdcxFPDPwr1FailcurrentRightmost power supply failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.16NotificationdcxFPDPwr1FailClrcurrentRightmost power supply is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.17NotificationdcxFPDPwr2FailcurrentLeftmost power supply failed
1.3.6.1.4.1.4115.1.4.3.3.1.3.18NotificationdcxFPDPwr2FailClrcurrentLeftmost power supply is working
1.3.6.1.4.1.4115.1.4.3.3.1.3.19NotificationdcxFPDTempOkaycurrentSystem temperature is OK
1.3.6.1.4.1.4115.1.4.3.3.1.3.20NotificationdcxFPDTempBadcurrentSystem temperature is too hot!
1.3.6.1.4.1.4115.1.4.3.3.1.3.21NotificationdcxFPDTempCriticalcurrentSystem temperature is critical!!!, CMTS will shut itself down!!!!
1.3.6.1.4.1.4115.1.4.3.3.1.4NodedcxFPDConformance
1.3.6.1.4.1.4115.1.4.3.3.1.4.1NodedcxFPDCompliances
1.3.6.1.4.1.4115.1.4.3.3.1.4.1.1CompliancedcxFPDCompliancecurrentThe compliance statement for devices that implement Arris C3 compliant FPD features
1.3.6.1.4.1.4115.1.4.3.3.1.4.2NodedcxFPDGroups
1.3.6.1.4.1.4115.1.4.3.3.1.4.2.1GroupdcxFPDMsgGroupcurrentArris C3 FPD message group
1.3.6.1.4.1.4115.1.4.3.3.1.4.2.2GroupdcxFPDControlConfGroupcurrentArris C3 FPD Control group