MIB Viewer

ARRIS-C3-SM-MIB

81 objects
This MIB manages the System Manager software on the Arris CMTS C3
Imported Objects
ARRIS-MIBcmtsC3
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.4115.1.4.3.4IdentitycmtsC3SMMIBThis MIB manages the System Manager software on the Arris CMTS C3
1.3.6.1.4.1.4115.1.4.3.4.1NodedcxSMObjects
1.3.6.1.4.1.4115.1.4.3.4.1.1NodedcxSMBootGroup
1.3.6.1.4.1.4115.1.4.3.4.1.1.1ScalardcxSMBootDeviceread-writecurrentSpecify device CMTS will by default boot from
1.3.6.1.4.1.4115.1.4.3.4.1.1.2ScalardcxSMBootHostnameread-writecurrentIp address of tftp, nfs, ftp server, ignored when booting from flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.1.3ScalardcxSMBootUsernameread-writecurrentUser name for tftp, ftp, nfs server, ignored when booting from flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.1.4ScalardcxSMBootPasswordread-writecurrentUser password for tftp, ftp, nfs server, ignored when booting from flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.1.5ScalardcxSMBootPathread-writecurrentBoot path for image file on tftp, ftp, nfs server, ignored when booting from flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.1.6ScalardcxSMEnetMgmtInterfaceread-writecurrentSpecify Cmts management interface
1.3.6.1.4.1.4115.1.4.3.4.1.1.7ScalardcxSMRebootActionread-writecurrentForce a reboot of the CMTS
1.3.6.1.4.1.4115.1.4.3.4.1.2NodedcxSMConfigFileBootGroup
1.3.6.1.4.1.4115.1.4.3.4.1.2.1ScalardcxSMConfigFileBootDeviceread-writecurrentSpecify device from which CMTS will read it's configuration
1.3.6.1.4.1.4115.1.4.3.4.1.2.2ScalardcxSMConfigFileBootHostnameread-writecurrentIp address of tftp, nfs, ftp server, ignored when using flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.2.3ScalardcxSMConfigFileBootUsernameread-writecurrentUser name for tftp, ftp server, ignored when using flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.2.4ScalardcxSMConfigFileBootPasswordread-writecurrentUser password for tftp, ftp server, ignored when using flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.2.5ScalardcxSMConfigFileBootPathread-writecurrentBoot path for image file on tftp, ftp server, ignored when using flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.3NodedcxSMDownloadGroup
1.3.6.1.4.1.4115.1.4.3.4.1.3.1ScalardcxSMDownloadDeviceread-writecurrentSpecify device CMTS will by download from
1.3.6.1.4.1.4115.1.4.3.4.1.3.2ScalardcxSMDownloadHostnameread-writecurrentdownload ip address
1.3.6.1.4.1.4115.1.4.3.4.1.3.3ScalardcxSMDownloadUsernameread-writecurrentdownload user name
1.3.6.1.4.1.4115.1.4.3.4.1.3.4ScalardcxSMDownloadPasswordread-writecurrentdownload user password
1.3.6.1.4.1.4115.1.4.3.4.1.3.5ScalardcxSMDownloadPathread-writecurrentBoot path for image file on tftp, ftp
1.3.6.1.4.1.4115.1.4.3.4.1.3.6ScalardcxSMDownloadControlread-writecurrentBegin downloading by setting to start(1) abort a current download with abort(2) downloaded image will not become active until it made current in the softwareLi…
1.3.6.1.4.1.4115.1.4.3.4.1.3.7ScalardcxSMDownloadStatusread-onlycurrentnone(1) indicates no images has been downloaded since the CMTS rebooted, inprogress indicates there is an active download occuring, finished(3) indicates the d…
1.3.6.1.4.1.4115.1.4.3.4.1.4NodedcxSMTrapGroup
1.3.6.1.4.1.4115.1.4.3.4.1.4.1NotificationdcxSMDiskInsertedcurrentdisk inserted. Severity is WARNING
1.3.6.1.4.1.4115.1.4.3.4.1.4.2NotificationdcxSMDiskRemovedcurrentdisk removed. Severity is ERROR.
1.3.6.1.4.1.4115.1.4.3.4.1.4.3NotificationdcxSMDiskFailedcurrentdisk failed. Severity is ERROR.
1.3.6.1.4.1.4115.1.4.3.4.1.4.4NotificationdcxSMConfigChecksumChangedcurrentConfig file checksum is different compared to the config file used to initialize the cmts. Severity is WARNING.
1.3.6.1.4.1.4115.1.4.3.4.1.4.5NotificationdcxSMImageChecksumChangedcurrentConfig image checksum is different compared to the image used to boot the cmts. Severity is WARNING.
1.3.6.1.4.1.4115.1.4.3.4.1.4.6NotificationdcxSMImageDownloadFailedcurrentAn error occured while downloading the image file. Severity is ERROR.
1.3.6.1.4.1.4115.1.4.3.4.1.4.7NotificationdcxSMImageBootFailedcurrentAn error occured while booting. Severity is ERROR.
1.3.6.1.4.1.4115.1.4.3.4.1.5NodedcxSMConfigFileGroup
1.3.6.1.4.1.4115.1.4.3.4.1.5.1TabledcxSMConfigFileTablenot-accessiblecurrentTable of config files installed on CMTS flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.5.1.1RowdcxSMConfigFileEntrynot-accessiblecurrent.
1.3.6.1.4.1.4115.1.4.3.4.1.5.1.1.1ColumndcxSMConfigFileIndexnot-accessiblecurrentindex
1.3.6.1.4.1.4115.1.4.3.4.1.5.1.1.2ColumndcxSMConfigFileDateread-onlycurrentDate Config file last modified
1.3.6.1.4.1.4115.1.4.3.4.1.5.1.1.3ColumndcxSMConfigFileDescread-writecurrentDescription of config file
1.3.6.1.4.1.4115.1.4.3.4.1.5.1.1.4ColumndcxSMConfigFileChecksumread-onlycurrentchecksum
1.3.6.1.4.1.4115.1.4.3.4.1.5.1.1.5ColumndcxSMConfigFileSizeread-onlycurrentfile size
1.3.6.1.4.1.4115.1.4.3.4.1.5.1.1.6ColumndcxSMConfigFileStatusread-writecurrentStatus of config file may be currrent, alt or inactive current -> alt allowed config files swapped alt -> current allowed config files swapped inactive -> curr…
1.3.6.1.4.1.4115.1.4.3.4.1.6NodedcxSMSoftwareListGroup
1.3.6.1.4.1.4115.1.4.3.4.1.6.1TabledcxSMSoftwareListTablenot-accessiblecurrentTable of images installed on CMTS flash disk
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1RowdcxSMSoftwareListEntrynot-accessiblecurrent.
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1.1ColumndcxSMSoftwareIndexnot-accessiblecurrentimage index
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1.2ColumndcxSMSoftwareVersionread-onlycurrentimage version
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1.3ColumndcxSMSoftwareDateread-onlycurrentDate image created
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1.4ColumndcxSMSoftwareDescread-writecurrentDescription of image
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1.5ColumndcxSMSoftwareChecksumread-onlycurrentchecksum
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1.6ColumndcxSMSoftwareSizeread-onlycurrentfile size
1.3.6.1.4.1.4115.1.4.3.4.1.6.1.1.7ColumndcxSMSoftwareStatusread-writecurrentStatus of software may be currrent, alt or inactive current -> alt allowed software swapped alt -> current allowed software swapped inactive -> current allowed…
1.3.6.1.4.1.4115.1.4.3.4.1.7NodedcxSMMiscUserManagementGroup
1.3.6.1.4.1.4115.1.4.3.4.1.7.1TabledcxSMMiscUserTablenot-accessiblecurrentTable of CLI accounts
1.3.6.1.4.1.4115.1.4.3.4.1.7.1.1RowdcxSMMiscUserListEntrynot-accessiblecurrent.
1.3.6.1.4.1.4115.1.4.3.4.1.7.1.1.1ColumndcxSMMiscUserIndexnot-accessiblecurrentuser index
1.3.6.1.4.1.4115.1.4.3.4.1.7.1.1.2ColumndcxSMMiscUserLoginNameread-writecurrentLogin user name
1.3.6.1.4.1.4115.1.4.3.4.1.7.1.1.3ColumndcxSMMiscUserLoginPwdread-writecurrentLogin user password
1.3.6.1.4.1.4115.1.4.3.4.1.7.1.1.4ColumndcxSMMiscUserEnablePwdread-writecurrentLogin user name password to enter priviledged mode
1.3.6.1.4.1.4115.1.4.3.4.1.7.1.1.5ColumndcxSMMiscUserEnableSecretePwdread-writecurrentLogin user enable secret password to enter priviledged mode
1.3.6.1.4.1.4115.1.4.3.4.1.7.1.1.6ColumndcxSMMiscUserWorkModeread-writecurrentLogin user config mode
1.3.6.1.4.1.4115.1.4.3.4.1.8NodedcxIpdrGroup
1.3.6.1.4.1.4115.1.4.3.4.1.8.1ScalardcxIpdrEnableread-writecurrentEnable or disable Ipdr
1.3.6.1.4.1.4115.1.4.3.4.1.8.2ScalardcxIpdrFileNameread-writecurrentIpdr file name on the ftp server. Can not be changed while the collection system is retrieving or deleting the exisiting file or if the CMTS is building the cu…
1.3.6.1.4.1.4115.1.4.3.4.1.8.3ScalardcxIpdrUserLoginNameread-writecurrentFtp server login name for accessing Ipdr file. If set to 'anonymous', any non-zero length password will be accepted.
1.3.6.1.4.1.4115.1.4.3.4.1.8.4ScalardcxIpdrUserLoginPwdread-writecurrentFtp server login password for accessing Ipdr file. If dcxIpdrUserLoginName is 'anonymous', any non-zero length password will be accepted.
1.3.6.1.4.1.4115.1.4.3.4.2NodedcxDxmObjects
1.3.6.1.4.1.4115.1.4.3.4.2.1NodedcxDxmStatusGroup
1.3.6.1.4.1.4115.1.4.3.4.2.1.1ScalardcxDxmStatusIpAddressread-writecurrentSpecifies the IP address of the DoxMonitor managing this DoxController
1.3.6.1.4.1.4115.1.4.3.4.2.1.2ScalardcxDxmStatusPortread-writecurrentSpecifies the TCP/UDP Port us to connect to the appropriate DoxMonitor
1.3.6.1.4.1.4115.1.4.3.4.2.1.3ScalardcxDxmStatusEnableread-writecurrentSpecifies whether the DoxController should register with the specified DoxMonitor
1.3.6.1.4.1.4115.1.4.3.4.2.1.4ScalardcxDxmStatusCmtsIdread-onlycurrentSpecifies whether the DoxController should register with the specified DoxMonitor
1.3.6.1.4.1.4115.1.4.3.4.2.1.5ScalardcxDxmStatusRoleread-onlycurrentdescribes the DoxController's role in the DoxMonitor redundancy cluster, it is a Primary or Standby CMTS
1.3.6.1.4.1.4115.1.4.3.4.2.1.6ScalardcxDxmStatusStateread-onlycurrentSpecifies the current state of the DoxController
1.3.6.1.4.1.4115.1.4.3.4.2.1.7ScalardcxDxmStatusLastConfigRetrievalread-onlycurrentSpecifies when the startup-configuration was last retrieved from this DoxController
1.3.6.1.4.1.4115.1.4.3.4.2.1.8ScalardcxDxmStatusLastConfigChangeread-onlycurrentSpecifies when the startup-configuration was last changed on this DoxController
1.3.6.1.4.1.4115.1.4.3.4.2.1.9ScalardcxDxmStatusConfigRetrievalCountread-onlycurrentThe total number of times the DoxController has responded to a Config Retrieval Request
1.3.6.1.4.1.4115.1.4.3.4.2.1.10ScalardcxDxmStatusHeartbeatCountread-onlycurrentThe total number of times the DoxController has responded to a Heartbeat Request
1.3.6.1.4.1.4115.1.4.3.4.2.1.11ScalardcxDxmStatusNotifAddCmCountread-onlycurrentThe total number of times the DoxController has generated an AddCableModem Notification
1.3.6.1.4.1.4115.1.4.3.4.2.1.12ScalardcxDxmStatusNotifDelCmCountread-onlycurrentThe total number of times the DoxController has generated an DeleteCableModem Notification
1.3.6.1.4.1.4115.1.4.3.4.2.1.13ScalardcxDxmStatusNotifAddCpeCountread-onlycurrentThe total number of times the DoxController has generated an AddCpe Notification
1.3.6.1.4.1.4115.1.4.3.4.2.1.14ScalardcxDxmStatusNotifDelCpeCountread-onlycurrentThe total number of times the DoxController has generated a DeleteCpe Notification