MIB Viewer

ARRIS-NET-PERF-MONITOR-MIB

44 objects
This MIB module supplies the basic proprietary management objects for ARRIS modems.
OIDNameAccessStatusDescription
1.3.6.1.4.1.4115.1.3.13IdentityarrisNetPerfMonitorMibThis MIB module supplies the basic proprietary management objects for ARRIS modems.
1.3.6.1.4.1.4115.1.3.13.1NodearrisNpmSetup
1.3.6.1.4.1.4115.1.3.13.1.1ScalararrisNpmSetupBgTrafficRateEnableread-writecurrentThe setting of this MIB enables the CM to enforce background traffic rate checking before attempting to run any NPM tests. Disabling the background traffic tes…
1.3.6.1.4.1.4115.1.3.13.1.2ScalararrisNpmSetupBgTrafficMaxDownstreamRateread-writecurrentThis MIB controls the maximum background downstream traffic rate that the CM can be passing and still run the NPM tests. The traffic rate is determined by moni…
1.3.6.1.4.1.4115.1.3.13.1.3ScalararrisNpmSetupBgTrafficMaxUpstreamRateread-writecurrentThis MIB controls the maximum background upstream traffic rate that the CM can be passing and still run the NPM tests. The traffic rate is determined by monito…
1.3.6.1.4.1.4115.1.3.13.1.4ScalararrisNpmSetupGroupReferenceread-writecurrentThis MIB object is provided to allow the SNMP NMS record the name of any logical grouping that the CM maybe associated with at the offset of the tests. The val…
1.3.6.1.4.1.4115.1.3.13.2NodearrisNpmWebDlTest
1.3.6.1.4.1.4115.1.3.13.2.1ScalararrisNpmSetupWebPageDlTestRunTimeread-writecurrentThis MIB indicates to the modem to run the Web Page Download test. The supplied time is used as a countdown timer, indicating the number of seconds to wait bef…
1.3.6.1.4.1.4115.1.3.13.2.2ScalararrisNpmSetupWebPageDlTestTimeoutread-writecurrentThis MIB indicates how long the Webpage Download test should wait for an attempt to download a URL before marking the attempt as a failure.
1.3.6.1.4.1.4115.1.3.13.2.3TablearrisNpmSetupWebPageDlTestTablenot-accessiblecurrentThis table contains the URLs to be used by the Web Page Download Test. When the test runs, the cable modem attempts to download the main page associated with e…
1.3.6.1.4.1.4115.1.3.13.2.3.1RowarrisNpmSetupWebPageDlTestEntrynot-accessiblecurrentAn entry describing the URLs used in the Web Page Download Test.
1.3.6.1.4.1.4115.1.3.13.2.3.1.1ColumnarrisNpmSetupWebPageDlTestConfigIndexnot-accessiblecurrentThis index is used as a simple value to act as the index into the arrisNpmSetupWebPageDlTestTable, as opposed to using the full URL name as the index.
1.3.6.1.4.1.4115.1.3.13.2.3.1.2ColumnarrisNpmSetupWebPageDlTestConfigUrlread-writecurrentThis object is used as the index into the Web Page Download test URL configuration table, and is the actual
1.3.6.1.4.1.4115.1.3.13.2.3.1.3ColumnarrisNpmSetupWebPageDlTestConfigRowStatusread-createcurrentThe RowStats for contolling entries in the this table.
1.3.6.1.4.1.4115.1.3.13.2.4TablearrisNpmResultWebPageDlTestTablenot-accessiblecurrentThis table contains the results from the running of the Web Page Download Test. Each entry setup in the arrisNpmSetupWebPageDlTestTable has a corresponding ent…
1.3.6.1.4.1.4115.1.3.13.2.4.1RowarrisNpmResultWebPageDlTestEntrynot-accessiblecurrentAn entry describing the URLs used in the Web Page Download Test. Please note that the index used is related to the other arrisNpmSetupWebPageDlTestTable index.
1.3.6.1.4.1.4115.1.3.13.2.4.1.1ColumnarrisNpmResultWebPageDlTestResultread-onlycurrentThis object contains a JSON formatted string containing the results associated with running the webpage download test using the URL in the corresponding arrisN…
1.3.6.1.4.1.4115.1.3.13.3NodearrisNpmDnsTest
1.3.6.1.4.1.4115.1.3.13.3.1ScalararrisNpmSetupDnsTestEnableread-writecurrentIf this MIB is set to 'enable' then the CM must run the DNS Latency test before running the Web Page Download test. The default is to not run the DNS Latency t…
1.3.6.1.4.1.4115.1.3.13.3.2ScalararrisNpmSetupDnsTestRunTimeread-writecurrentThis MIB indicates to the modem to run the DNS Latency test. The supplied time is used as a countdown timer, indicating the number of seconds to wait before ru…
1.3.6.1.4.1.4115.1.3.13.3.3ScalararrisNpmSetupDnsTestRunTimeTimeoutread-writecurrentThis MIB indicates how long the Webpage Download test should wait for an attempt to download a URL before marking the attempt as a failure.
1.3.6.1.4.1.4115.1.3.13.3.4ScalararrisNpmSetupDnsPrimaryServerIpTyperead-writecurrentThis MIB is used to setup the IP address details of the Primary DNS server to use if the DHCP supplied values are not to be used
1.3.6.1.4.1.4115.1.3.13.3.5ScalararrisNpmSetupDnsPrimaryServerIpAddressread-writecurrentThis MIB is used to setup the IP address details of the Primary DNS server to use if the DHCP supplied values are not to be used. By default this value is set …
1.3.6.1.4.1.4115.1.3.13.3.6ScalararrisNpmSetupDnsSecondaryServerIpTyperead-writecurrentThis MIB is used to setup the IP address details of the Secondary DNS server to use if the DHCP supplied values are not to be used
1.3.6.1.4.1.4115.1.3.13.3.7ScalararrisNpmSetupDnsSecondaryServerIpAddressread-writecurrentThis MIB is used to setup the IP address details of the Secondary DNS server to use if the DHCP supplied values are not to be used. By default this value is se…
1.3.6.1.4.1.4115.1.3.13.3.8TablearrisNpmResultDnsTestTablenot-accessiblecurrentThis table contains the results from the running of the DNS Latency Test. Each entry setup in the arrisNpmSetupWebPageDlTestTable has a corresponding entry in …
1.3.6.1.4.1.4115.1.3.13.3.8.1RowarrisNpmResultDnsTestEntrynot-accessiblecurrentAn entry describing the URLs used in the Web Page Download Test. Please note that the index used is related to the other arrisNpmSetupWebPageDlTestTable index.
1.3.6.1.4.1.4115.1.3.13.3.8.1.1ColumnarrisNpmResultDnsTestResultIndexnot-accessiblecurrentThis index is used as a simple value to act as the index into the arrisNpmResultDnsTestTable.
1.3.6.1.4.1.4115.1.3.13.3.8.1.2ColumnarrisNpmResultDnsTestResultread-onlycurrentThis object contains a JSON formatted string containing the results associated with running the webpage download test using the URL in the corresponding arrisN…
1.3.6.1.4.1.4115.1.3.13.4NodearrisNpmNetLatencyTest
1.3.6.1.4.1.4115.1.3.13.4.1ScalararrisNpmSetupNetLatencyTestRunUnderLoadEnableread-writecurrentIf this MIB object is set to 'enable' then the CM must run the Network Latency test repeatedly during the Web Page Download test. The purpose of this test cond…
1.3.6.1.4.1.4115.1.3.13.4.2ScalararrisNpmSetupNetLatencyTestRunTimeread-writecurrentThis MIB indicates to the modem to run the Network Latency test. The supplied time is used as a countdown timer, indicating the number of seconds to wait befor…
1.3.6.1.4.1.4115.1.3.13.4.3ScalararrisNpmSetupNetLatencyTestPingCountread-writecurrentThis MIB indicates to the modem how many UDP Ping requests to issue to each of the conigured test node servers. The interval between each ping is goverened by …
1.3.6.1.4.1.4115.1.3.13.4.4ScalararrisNpmSetupNetLatencyTestPingIntervalread-writecurrentThis MIB indicates to the modem what interval to use between successive UDP Pings to each configured test server.
1.3.6.1.4.1.4115.1.3.13.4.5ScalararrisNpmSetupNetLatencyTestPingTimeoutread-writecurrentThis MIB indicates to the modem how long to wait for a UDP Ping response before declaring that the UDP Ping request failed. The units are in seconds.
1.3.6.1.4.1.4115.1.3.13.4.6TablearrisNpmSetupNetLatencyServerTablenot-accessiblecurrentThis table contains the results from the running of the DNS Latency Test. Each entry setup in the arrisNpmSetupWebPageDlTestTable has a corresponding entry in …
1.3.6.1.4.1.4115.1.3.13.4.6.1RowarrisNpmSetupNetLatencyServerEntrynot-accessiblecurrentAn entry describing the URLs used in the Network Latency Test. This table must be configured with at least one entry in order for the Network Latency test to r…
1.3.6.1.4.1.4115.1.3.13.4.6.1.1ColumnarrisNpmSetupNetLatencyConfigIndexnot-accessiblecurrentAbritrary index used to coordinates entries in this table.
1.3.6.1.4.1.4115.1.3.13.4.6.1.2ColumnarrisNpmSetupNetLatencyConfigServerread-writecurrentThis MIB object can store either theIPv4 n.n.n.n address or a FQDN of the Primary Network Latency test server that the CM must transmit UDP ping packets to.
1.3.6.1.4.1.4115.1.3.13.4.6.1.3ColumnarrisNpmSetupNetLatencyConfigServerPortread-writecurrentThis MIB object defines the UDP destination port that the CM must transmit its UDP Ping packet to. Each Server can have its own UDP port number.
1.3.6.1.4.1.4115.1.3.13.4.6.1.4ColumnarrisNpmSetupNetLatencyConfigServerRowStatusread-createcurrentThe RowStats for controling entries in the this table.
1.3.6.1.4.1.4115.1.3.13.4.7TablearrisNpmResultNetLatencyTestTablenot-accessiblecurrentThis table contains the results from the running of the Network Latency Test. Each entry in the arrisNpmSetupNetLatencyServerTable has a corresponding entry in…
1.3.6.1.4.1.4115.1.3.13.4.7.1RowarrisNpmResultNetLatencyTestEntrynot-accessiblecurrentAn entry describing the results of the Netowrk Latency test on the configured test servers.
1.3.6.1.4.1.4115.1.3.13.4.7.1.1ColumnarrisNpmResultNetLatencyTestResultread-onlycurrentThis object contains a JSON formatted string containing the results associated with running the network latency test using the configured server addresses. The…