MIB Viewer

ASYNCOS-MAIL-MIB

64 objects
MIB for Cisco IronPort Mail Gateway/Email Security Appliances
Imported Objects
IRONPORT-SMIasyncOSMail
SNMPv2-SMICounter32 Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.15497.1.1.1IdentityasyncOSMailObjectsMIB for Cisco IronPort Mail Gateway/Email Security Appliances
1.3.6.1.4.1.15497.1.1.1.1ScalarperCentMemoryUtilizationread-onlycurrentThis object provides a general idea of how much memory is being consumed by the appliance software.
1.3.6.1.4.1.15497.1.1.1.2ScalarperCentCPUUtilizationread-onlycurrentThis object provides a general idea of how busy the CPU is according to the appliance software, within the last 5 seconds of utilization. This measurement may …
1.3.6.1.4.1.15497.1.1.1.3ScalarperCentDiskIOUtilizationread-onlycurrentThis object provides a general idea of how much disk I/O has been generated within the last 5-15 seconds.
1.3.6.1.4.1.15497.1.1.1.4ScalarperCentQueueUtilizationread-onlycurrentPercent of total queue capacity used.
1.3.6.1.4.1.15497.1.1.1.5ScalarqueueAvailabilityStatusread-onlycurrentQueue space status: enough space, queue near full or queue full.
1.3.6.1.4.1.15497.1.1.1.6ScalarresourceConservationReasonread-onlycurrentReason system is in Resource Conservation Mode.
1.3.6.1.4.1.15497.1.1.1.7ScalarmemoryAvailabilityStatusread-onlycurrentMail Transfer process's memory availability status.
1.3.6.1.4.1.15497.1.1.1.8TablepowerSupplyTablenot-accessiblecurrentA table of one or power supply entries.
1.3.6.1.4.1.15497.1.1.1.8.1RowpowerSupplyEntrynot-accessiblecurrentEntry containing the status of a power supply and the corresponding power supply configuration redundancy state.
1.3.6.1.4.1.15497.1.1.1.8.1.1ColumnpowerSupplyIndexread-onlycurrentUnique index for a power supply source. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.8.1.2ColumnpowerSupplyStatusread-onlycurrentRepresents the status of a power supply. powerSupplyNotInstalled - The power supply is not detected by the chassis as being physically present. powerSupplyHeal…
1.3.6.1.4.1.15497.1.1.1.8.1.3ColumnpowerSupplyRedundancyread-onlycurrentRepresents the status of a collection of one or more power supplies. powerSupplyRedundancyOK - All power supplies are in a powerSupplyHealthy state. powerSuppl…
1.3.6.1.4.1.15497.1.1.1.8.1.4ColumnpowerSupplyNameread-onlycurrentA textual name for a power supply.
1.3.6.1.4.1.15497.1.1.1.9TabletemperatureTablenot-accessiblecurrentA table of chassis temperature sensor states.
1.3.6.1.4.1.15497.1.1.1.9.1RowtemperatureEntrynot-accessiblecurrentAn entry in the temperature sensor table representing the status of the corresponding sensor in or on the appliance.
1.3.6.1.4.1.15497.1.1.1.9.1.1ColumntemperatureIndexnot-accessiblecurrentUnique index for the temperature sensor being instrumented. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.9.1.2ColumndegreesCelsiusread-onlycurrentTemperature reading for the sensor being instrumented in Centrigrade units. This is correct according to the relative accuracy of the sensor being instrumented.
1.3.6.1.4.1.15497.1.1.1.9.1.3ColumntemperatureNameread-onlycurrentTextual description for sensor being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the i…
1.3.6.1.4.1.15497.1.1.1.10TablefanTablenot-accessiblecurrentA table of chassis fan entries.
1.3.6.1.4.1.15497.1.1.1.10.1RowfanEntrynot-accessiblecurrentAn entry in the chassis fan table with the speed of a fan in the chassis, as well as the name of the corresponding fan.
1.3.6.1.4.1.15497.1.1.1.10.1.1ColumnfanIndexnot-accessiblecurrentUnique index of the chassis fan being instrumented. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.10.1.2ColumnfanRPMsread-onlycurrentSpeed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow require…
1.3.6.1.4.1.15497.1.1.1.10.1.3ColumnfanNameread-onlycurrentA textual name of the chassis fan being instrumented.
1.3.6.1.4.1.15497.1.1.1.11ScalarworkQueueMessagesread-onlycurrentNumber of messages in the work queue.
1.3.6.1.4.1.15497.1.1.1.12TablekeyExpirationTablenot-accessiblecurrentA table of Feature Key expiration entries.
1.3.6.1.4.1.15497.1.1.1.12.1RowkeyExpirationEntrynot-accessiblecurrentEntry containing a Feature Key, its expiration status, and whether or not the Feature Key is perpetual.
1.3.6.1.4.1.15497.1.1.1.12.1.1ColumnkeyExpirationIndexread-onlycurrentUnique index for a Feature Key applicable to the appliance. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.12.1.2ColumnkeyDescriptionread-onlycurrentTextual description for a Feature Key applicable to the appliance.
1.3.6.1.4.1.15497.1.1.1.12.1.3ColumnkeyIsPerpetualread-onlycurrentBoolean value represented by True if Feature Key is perpetual, or False if the Feature Key is normal or expired.
1.3.6.1.4.1.15497.1.1.1.12.1.4ColumnkeySecondsUntilExpireread-onlycurrentSeconds until the valid Feature Key expires. Only applies to non-perpetual Feature Keys, and is 0 when the Feature Key has expired.
1.3.6.1.4.1.15497.1.1.1.13TableupdateTablenot-accessiblecurrentA table of one or more update entries.
1.3.6.1.4.1.15497.1.1.1.13.1RowupdateEntrynot-accessiblecurrentEntry containing a name and number of successful and failed updates for a service, including but not limited to: spam or virus definitions and timezone updates.
1.3.6.1.4.1.15497.1.1.1.13.1.1ColumnupdateIndexread-onlycurrentUnique index for an update service. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.13.1.2ColumnupdateServiceNameread-onlycurrentA textual name for an update entry.
1.3.6.1.4.1.15497.1.1.1.13.1.3Columnupdatesread-onlycurrentThe number of successful attempts that have occurred when updating a service.
1.3.6.1.4.1.15497.1.1.1.13.1.4ColumnupdateFailuresread-onlycurrentThe number of failed attempts that have occurred when updating a service.
1.3.6.1.4.1.15497.1.1.1.14ScalaroldestMessageAgeread-onlycurrentThe number of seconds the oldest message has been in queue
1.3.6.1.4.1.15497.1.1.1.15ScalaroutstandingDNSRequestsread-onlycurrentNumber of DNS requests that have been sent but for which no reply has been received.
1.3.6.1.4.1.15497.1.1.1.16ScalarpendingDNSRequestsread-onlycurrentNumber of DNS requests waiting to be sent.
1.3.6.1.4.1.15497.1.1.1.17ScalarraidEventsread-onlycurrentThe total number of RAID events that have occurred since the last appliance power on event.
1.3.6.1.4.1.15497.1.1.1.18TableraidTablenot-accessiblecurrentUnique index for a drive being instrumented in the appliance. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.18.1RowraidEntrynot-accessiblecurrentAn entry in the RAID table representing the status of a drive attached to a RAID controller in the appliance.
1.3.6.1.4.1.15497.1.1.1.18.1.1ColumnraidIndexread-onlycurrentUnique index for a drive attached to a RAID controller in the appliance. This index is for SNMP purposes only; it has no intrinsic value.
1.3.6.1.4.1.15497.1.1.1.18.1.2ColumnraidStatusread-onlycurrentRepresents the status of a a drive attached to a RAID controller in the appliance. driveHealthy - The corresponding drive is connected to the RAID controller a…
1.3.6.1.4.1.15497.1.1.1.18.1.3ColumnraidIDread-onlycurrentA textual name for a drive attached to a RAID controller in the appliance.
1.3.6.1.4.1.15497.1.1.1.18.1.4ColumnraidLastErrorread-onlycurrentThe textual description of the last error message reported by the RAID controller or corresponding driver if one has occurred. This is 'No Error' if the corres…
1.3.6.1.4.1.15497.1.1.1.19ScalaropenFilesOrSocketsread-onlycurrentThis object notes how many files or sockets are open on the appliance. In normal operating conditions, the measurement is taken at least once every 5-15 second…
1.3.6.1.4.1.15497.1.1.1.20ScalarmailTransferThreadsread-onlycurrentNumber of threads that perform some task related to transferring mail.
1.3.6.1.4.1.15497.1.1.1.21ScalarconnectionURLaccessible-for-notifycurrentThe URL which will be used to test HTTP URL connectivity.
1.3.6.1.4.1.15497.1.1.1.22ScalarhsmErrorReasonread-onlycurrentA textual reason describing the last HSM authentication error.
1.3.6.1.4.1.15497.1.1.2NodeasyncOSMailNotifications
1.3.6.1.4.1.15497.1.1.2.1NotificationresourceConservationModecurrentMemory or queue utilization caused system to enter resource conservation mode.
1.3.6.1.4.1.15497.1.1.2.2NotificationpowerSupplyStatusChangecurrentA powerSupplyStatusChange notification is sent when power supply with powerSupplyName changes states, as per one of the states available in powerSupplyStatus. …
1.3.6.1.4.1.15497.1.1.2.3NotificationhighTemperaturecurrentA highTemperature notification is sent when the temperature of an instrumented sensor in the chassis has exceeded vendor defined specifications. This notificat…
1.3.6.1.4.1.15497.1.1.2.4NotificationfanFailurecurrentA fanFailure notification is sent when the speed of the fan is not operating per the vendor defined specifications, as discussed in fanRPMs. This notification …
1.3.6.1.4.1.15497.1.1.2.5NotificationkeyExpirationcurrentA keyExpiration notification is sent when the corresponding Feature Key is pending expiration or has expired. This notification contains the opaque type for th…
1.3.6.1.4.1.15497.1.1.2.6NotificationupdateFailurecurrentAn updateFailure notification is sent when a service fails to update properly. This notification contains the opaque type for the updateServiceName of the upda…
1.3.6.1.4.1.15497.1.1.2.7NotificationraidStatusChangecurrentA raidStatusChange notification is sent when drive with raidID changes states, as per one of the states available in raidStatus. This notification contains the…
1.3.6.1.4.1.15497.1.1.2.8NotificationconnectivityFailurecurrentA connectivityFailure notification is sent when the URL denoted by configured connectionURL is unreachable, or the request returned an HTTP code was not betwee…
1.3.6.1.4.1.15497.1.1.2.9NotificationmemoryUtilizationExceededcurrentA memoryUtilizationExceeded notification is sent when the value in perCentMemoryUtilization has exceeded the configured memory usage threshold. The percentage …
1.3.6.1.4.1.15497.1.1.2.10NotificationcpuUtilizationExceededcurrentA cpuUtilizationExceeded notification is sent when the value in perCentCPUUtilization has exceeded the configured CPU usage threshold. The percentage that exce…
1.3.6.1.4.1.15497.1.1.2.11NotificationhsmInitializationFailurecurrentA hsmInitializationFailure notification is sent when the Hardware Security Module card cannot be initialized. The initialization error in hsmErrorReason is ret…
1.3.6.1.4.1.15497.1.1.2.12NotificationhsmResetLoginFailurecurrentA hsmResetLoginFailure notification is sent when the Hardware Security Module card is reset due to multiple Crypto Officer login failures. The reset login erro…