ASYNCOS-MAIL-MIB
64 objects
MIB for Cisco IronPort Mail Gateway/Email Security Appliances
Imported Objects
| IRONPORT-SMI | asyncOSMail |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.15497.1.1.1 | IdentityasyncOSMailObjects | MIB for Cisco IronPort Mail Gateway/Email Security Appliances | ||
| 1.3.6.1.4.1.15497.1.1.1.1 | ScalarperCentMemoryUtilization | read-only | current | This object provides a general idea of how much memory is being consumed by the appliance software. |
| 1.3.6.1.4.1.15497.1.1.1.2 | ScalarperCentCPUUtilization | read-only | current | This object provides a general idea of how busy the CPU is according to the appliance software, within the last 5 seconds of utilization. This measurement may … |
| 1.3.6.1.4.1.15497.1.1.1.3 | ScalarperCentDiskIOUtilization | read-only | current | This object provides a general idea of how much disk I/O has been generated within the last 5-15 seconds. |
| 1.3.6.1.4.1.15497.1.1.1.4 | ScalarperCentQueueUtilization | read-only | current | Percent of total queue capacity used. |
| 1.3.6.1.4.1.15497.1.1.1.5 | ScalarqueueAvailabilityStatus | read-only | current | Queue space status: enough space, queue near full or queue full. |
| 1.3.6.1.4.1.15497.1.1.1.6 | ScalarresourceConservationReason | read-only | current | Reason system is in Resource Conservation Mode. |
| 1.3.6.1.4.1.15497.1.1.1.7 | ScalarmemoryAvailabilityStatus | read-only | current | Mail Transfer process's memory availability status. |
| 1.3.6.1.4.1.15497.1.1.1.8 | TablepowerSupplyTable | not-accessible | current | A table of one or power supply entries. |
| 1.3.6.1.4.1.15497.1.1.1.8.1 | RowpowerSupplyEntry | not-accessible | current | Entry containing the status of a power supply and the corresponding power supply configuration redundancy state. |
| 1.3.6.1.4.1.15497.1.1.1.8.1.1 | ColumnpowerSupplyIndex | read-only | current | Unique index for a power supply source. This index is for SNMP purposes only; it has no intrinsic value. |
| 1.3.6.1.4.1.15497.1.1.1.8.1.2 | ColumnpowerSupplyStatus | read-only | current | Represents the status of a power supply. powerSupplyNotInstalled - The power supply is not detected by the chassis as being physically present. powerSupplyHeal… |
| 1.3.6.1.4.1.15497.1.1.1.8.1.3 | ColumnpowerSupplyRedundancy | read-only | current | Represents the status of a collection of one or more power supplies. powerSupplyRedundancyOK - All power supplies are in a powerSupplyHealthy state. powerSuppl… |
| 1.3.6.1.4.1.15497.1.1.1.8.1.4 | ColumnpowerSupplyName | read-only | current | A textual name for a power supply. |
| 1.3.6.1.4.1.15497.1.1.1.9 | TabletemperatureTable | not-accessible | current | A table of chassis temperature sensor states. |
| 1.3.6.1.4.1.15497.1.1.1.9.1 | RowtemperatureEntry | not-accessible | current | An entry in the temperature sensor table representing the status of the corresponding sensor in or on the appliance. |
| 1.3.6.1.4.1.15497.1.1.1.9.1.1 | ColumntemperatureIndex | not-accessible | current | Unique index for the temperature sensor being instrumented. This index is for SNMP purposes only; it has no intrinsic value. |
| 1.3.6.1.4.1.15497.1.1.1.9.1.2 | ColumndegreesCelsius | read-only | current | Temperature reading for the sensor being instrumented in Centrigrade units. This is correct according to the relative accuracy of the sensor being instrumented. |
| 1.3.6.1.4.1.15497.1.1.1.9.1.3 | ColumntemperatureName | read-only | current | Textual description for sensor being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the i… |
| 1.3.6.1.4.1.15497.1.1.1.10 | TablefanTable | not-accessible | current | A table of chassis fan entries. |
| 1.3.6.1.4.1.15497.1.1.1.10.1 | RowfanEntry | not-accessible | current | An entry in the chassis fan table with the speed of a fan in the chassis, as well as the name of the corresponding fan. |
| 1.3.6.1.4.1.15497.1.1.1.10.1.1 | ColumnfanIndex | not-accessible | current | Unique index of the chassis fan being instrumented. This index is for SNMP purposes only; it has no intrinsic value. |
| 1.3.6.1.4.1.15497.1.1.1.10.1.2 | ColumnfanRPMs | read-only | current | Speed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow require… |
| 1.3.6.1.4.1.15497.1.1.1.10.1.3 | ColumnfanName | read-only | current | A textual name of the chassis fan being instrumented. |
| 1.3.6.1.4.1.15497.1.1.1.11 | ScalarworkQueueMessages | read-only | current | Number of messages in the work queue. |
| 1.3.6.1.4.1.15497.1.1.1.12 | TablekeyExpirationTable | not-accessible | current | A table of Feature Key expiration entries. |
| 1.3.6.1.4.1.15497.1.1.1.12.1 | RowkeyExpirationEntry | not-accessible | current | Entry containing a Feature Key, its expiration status, and whether or not the Feature Key is perpetual. |
| 1.3.6.1.4.1.15497.1.1.1.12.1.1 | ColumnkeyExpirationIndex | read-only | current | Unique index for a Feature Key applicable to the appliance. This index is for SNMP purposes only; it has no intrinsic value. |
| 1.3.6.1.4.1.15497.1.1.1.12.1.2 | ColumnkeyDescription | read-only | current | Textual description for a Feature Key applicable to the appliance. |
| 1.3.6.1.4.1.15497.1.1.1.12.1.3 | ColumnkeyIsPerpetual | read-only | current | Boolean value represented by True if Feature Key is perpetual, or False if the Feature Key is normal or expired. |
| 1.3.6.1.4.1.15497.1.1.1.12.1.4 | ColumnkeySecondsUntilExpire | read-only | current | Seconds until the valid Feature Key expires. Only applies to non-perpetual Feature Keys, and is 0 when the Feature Key has expired. |
| 1.3.6.1.4.1.15497.1.1.1.13 | TableupdateTable | not-accessible | current | A table of one or more update entries. |
| 1.3.6.1.4.1.15497.1.1.1.13.1 | RowupdateEntry | not-accessible | current | Entry containing a name and number of successful and failed updates for a service, including but not limited to: spam or virus definitions and timezone updates. |
| 1.3.6.1.4.1.15497.1.1.1.13.1.1 | ColumnupdateIndex | read-only | current | Unique index for an update service. This index is for SNMP purposes only; it has no intrinsic value. |
| 1.3.6.1.4.1.15497.1.1.1.13.1.2 | ColumnupdateServiceName | read-only | current | A textual name for an update entry. |
| 1.3.6.1.4.1.15497.1.1.1.13.1.3 | Columnupdates | read-only | current | The number of successful attempts that have occurred when updating a service. |
| 1.3.6.1.4.1.15497.1.1.1.13.1.4 | ColumnupdateFailures | read-only | current | The number of failed attempts that have occurred when updating a service. |
| 1.3.6.1.4.1.15497.1.1.1.14 | ScalaroldestMessageAge | read-only | current | The number of seconds the oldest message has been in queue |
| 1.3.6.1.4.1.15497.1.1.1.15 | ScalaroutstandingDNSRequests | read-only | current | Number of DNS requests that have been sent but for which no reply has been received. |
| 1.3.6.1.4.1.15497.1.1.1.16 | ScalarpendingDNSRequests | read-only | current | Number of DNS requests waiting to be sent. |
| 1.3.6.1.4.1.15497.1.1.1.17 | ScalarraidEvents | read-only | current | The total number of RAID events that have occurred since the last appliance power on event. |
| 1.3.6.1.4.1.15497.1.1.1.18 | TableraidTable | not-accessible | current | Unique index for a drive being instrumented in the appliance. This index is for SNMP purposes only; it has no intrinsic value. |
| 1.3.6.1.4.1.15497.1.1.1.18.1 | RowraidEntry | not-accessible | current | An entry in the RAID table representing the status of a drive attached to a RAID controller in the appliance. |
| 1.3.6.1.4.1.15497.1.1.1.18.1.1 | ColumnraidIndex | read-only | current | Unique index for a drive attached to a RAID controller in the appliance. This index is for SNMP purposes only; it has no intrinsic value. |
| 1.3.6.1.4.1.15497.1.1.1.18.1.2 | ColumnraidStatus | read-only | current | Represents the status of a a drive attached to a RAID controller in the appliance. driveHealthy - The corresponding drive is connected to the RAID controller a… |
| 1.3.6.1.4.1.15497.1.1.1.18.1.3 | ColumnraidID | read-only | current | A textual name for a drive attached to a RAID controller in the appliance. |
| 1.3.6.1.4.1.15497.1.1.1.18.1.4 | ColumnraidLastError | read-only | current | The textual description of the last error message reported by the RAID controller or corresponding driver if one has occurred. This is 'No Error' if the corres… |
| 1.3.6.1.4.1.15497.1.1.1.19 | ScalaropenFilesOrSockets | read-only | current | This object notes how many files or sockets are open on the appliance. In normal operating conditions, the measurement is taken at least once every 5-15 second… |
| 1.3.6.1.4.1.15497.1.1.1.20 | ScalarmailTransferThreads | read-only | current | Number of threads that perform some task related to transferring mail. |
| 1.3.6.1.4.1.15497.1.1.1.21 | ScalarconnectionURL | accessible-for-notify | current | The URL which will be used to test HTTP URL connectivity. |
| 1.3.6.1.4.1.15497.1.1.1.22 | ScalarhsmErrorReason | read-only | current | A textual reason describing the last HSM authentication error. |
| 1.3.6.1.4.1.15497.1.1.2 | NodeasyncOSMailNotifications | |||
| 1.3.6.1.4.1.15497.1.1.2.1 | NotificationresourceConservationMode | current | Memory or queue utilization caused system to enter resource conservation mode. | |
| 1.3.6.1.4.1.15497.1.1.2.2 | NotificationpowerSupplyStatusChange | current | A powerSupplyStatusChange notification is sent when power supply with powerSupplyName changes states, as per one of the states available in powerSupplyStatus. … | |
| 1.3.6.1.4.1.15497.1.1.2.3 | NotificationhighTemperature | current | A highTemperature notification is sent when the temperature of an instrumented sensor in the chassis has exceeded vendor defined specifications. This notificat… | |
| 1.3.6.1.4.1.15497.1.1.2.4 | NotificationfanFailure | current | A fanFailure notification is sent when the speed of the fan is not operating per the vendor defined specifications, as discussed in fanRPMs. This notification … | |
| 1.3.6.1.4.1.15497.1.1.2.5 | NotificationkeyExpiration | current | A keyExpiration notification is sent when the corresponding Feature Key is pending expiration or has expired. This notification contains the opaque type for th… | |
| 1.3.6.1.4.1.15497.1.1.2.6 | NotificationupdateFailure | current | An updateFailure notification is sent when a service fails to update properly. This notification contains the opaque type for the updateServiceName of the upda… | |
| 1.3.6.1.4.1.15497.1.1.2.7 | NotificationraidStatusChange | current | A raidStatusChange notification is sent when drive with raidID changes states, as per one of the states available in raidStatus. This notification contains the… | |
| 1.3.6.1.4.1.15497.1.1.2.8 | NotificationconnectivityFailure | current | A connectivityFailure notification is sent when the URL denoted by configured connectionURL is unreachable, or the request returned an HTTP code was not betwee… | |
| 1.3.6.1.4.1.15497.1.1.2.9 | NotificationmemoryUtilizationExceeded | current | A memoryUtilizationExceeded notification is sent when the value in perCentMemoryUtilization has exceeded the configured memory usage threshold. The percentage … | |
| 1.3.6.1.4.1.15497.1.1.2.10 | NotificationcpuUtilizationExceeded | current | A cpuUtilizationExceeded notification is sent when the value in perCentCPUUtilization has exceeded the configured CPU usage threshold. The percentage that exce… | |
| 1.3.6.1.4.1.15497.1.1.2.11 | NotificationhsmInitializationFailure | current | A hsmInitializationFailure notification is sent when the Hardware Security Module card cannot be initialized. The initialization error in hsmErrorReason is ret… | |
| 1.3.6.1.4.1.15497.1.1.2.12 | NotificationhsmResetLoginFailure | current | A hsmResetLoginFailure notification is sent when the Hardware Security Module card is reset due to multiple Crypto Officer login failures. The reset login erro… |