MIB Viewer

AT-PTP-MIB

196 objects
This MIB file contains definitions of managed objects for the IEEE 1588v2 Precision Time Protocol (PTP) module.
Imported Objects
AT-SMI-MIBmodules
IF-MIBInterfaceIndexOrZero
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Counter64 Gauge32 Integer32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TCAutonomousType DisplayString TEXTUAL-CONVENTION TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.207.8.4.4.4.504IdentityatPtpMIBThis MIB file contains definitions of managed objects for the IEEE 1588v2 Precision Time Protocol (PTP) module.
1.3.6.1.4.1.207.8.4.4.4.504.0NodeptpMIBNotifs
1.3.6.1.4.1.207.8.4.4.4.504.1NodeptpMIBObjects
1.3.6.1.4.1.207.8.4.4.4.504.1.1NodeptpMIBSystemInfo
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1TableptpSystemTablenot-accessiblecurrentTable of count information about the PTP system for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1RowptpSystemEntrynot-accessiblecurrentAn entry in the table, containing count information about a single domain. New row entries are added when the PTP clock for this domain is configured, while th…
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1.1ColumnptpDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices. The Clock Domain is a logical group of clocks and devices that synchroni…
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1.2ColumnptpInstanceIndexnot-accessiblecurrentThis object specifies the instance of the Clock for this domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1.3ColumnptpDomainClockPortsTotalread-onlycurrentThis object specifies the total number of clock ports configured within a domain in the system.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2TableptpSystemDomainTablenot-accessiblecurrent
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2.1RowptpSystemDomainEntrynot-accessiblecurrentAn entry in the table, containing information about a single clock mode for the PTP system. A row entry gets added when PTP clocks are configured on the node.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2.1.1ColumnptpSystemDomainClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2.1.2ColumnptpSystemDomainTotalsread-onlycurrentThis object specifies the total number of PTP domains for this particular clock type configured in this node.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.3ScalarptpSystemProfileread-onlycurrentThis object specifies the PTP Profile implemented on the system.
1.3.6.1.4.1.207.8.4.4.4.504.1.2NodeptpMIBClockInfo
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1TableptpClockCurrentDSTablenot-accessiblecurrentTable of information about the PTP clock Current Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1RowptpClockCurrentDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock Current Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.1ColumnptpClockCurrentDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.2ColumnptpClockCurrentDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.3ColumnptpClockCurrentDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.4ColumnptpClockCurrentDSStepsRemovedread-onlycurrentThe current clock dataset StepsRemoved value. This object specifies the distance measured by the number of Boundary clocks between the local clock and the Fore…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.5ColumnptpClockCurrentDSOffsetFromMasterread-onlycurrentThis object specifies the current clock dataset ClockOffset value. The value of the computation of the offset in time between a slave and a master clock.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.6ColumnptpClockCurrentDSMeanPathDelayread-onlycurrentThis object specifies the current clock dataset MeanPathDelay value. The mean path delay between a pair of ports as measured by the delay request-response mech…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2TableptpClockParentDSTablenot-accessiblecurrentTable of information about the PTP clock Parent Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1RowptpClockParentDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock Parent Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.1ColumnptpClockParentDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.2ColumnptpClockParentDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.3ColumnptpClockParentDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.4ColumnptpClockParentDSParentPortIdentityread-onlycurrentThis object specifies the value of portIdentity of the port on the master that issues the Sync messages used in synchronizing this clock.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.5ColumnptpClockParentDSParentStatsread-onlycurrentThis object specifies the Parent Dataset ParentStats value. This value indicates whether the values of ParentDSOffset and ParentDSClockPhChRate have been measu…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.6ColumnptpClockParentDSOffsetread-onlycurrentThis object specifies the Parent Dataset ParentOffsetScaledLogVariance value. This value is the variance of the parent clock's phase as measured by the local c…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.7ColumnptpClockParentDSClockPhChRateread-onlycurrentThis object specifies the clock's parent dataset ParentClockPhaseChangeRate value. This value is an estimate of the parent clock's phase change rate as measure…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.8ColumnptpClockParentDSGMClockIdentityread-onlycurrentThis object specifies the parent dataset Grandmaster clock identity.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.9ColumnptpClockParentDSGMClockPriority1read-onlycurrentThis object specifies the parent dataset Grandmaster clock priority1.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.10ColumnptpClockParentDSGMClockPriority2read-onlycurrentThis object specifies the parent dataset grandmaster clock priority2.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.11ColumnptpClockParentDSGMClockQualityClassread-onlycurrentThis object specifies the parent dataset grandmaster clock quality class.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.12ColumnptpClockParentDSGMClockQualityAccuracyread-onlycurrentThis object specifies the parent dataset grandmaster clock quality accuracy.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.13ColumnptpClockParentDSGMClockQualityOffsetread-onlycurrentThis object specifies the parent dataset grandmaster clock quality offset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3TableptpClockDefaultDSTablenot-accessiblecurrentTable of information about the PTP clock Default Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1RowptpClockDefaultDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock Default Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.1ColumnptpClockDefaultDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.2ColumnptpClockDefaultDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.3ColumnptpClockDefaultDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.4ColumnptpClockDefaultDSTwoStepFlagread-onlycurrentThis object specifies whether the Two Step process is used.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.5ColumnptpClockDefaultDSClockIdentityread-onlycurrentThis object specifies the default Datasets clock identity.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.6ColumnptpClockDefaultDSPriority1read-onlycurrentThis object specifies the default Datasets clock Priority1.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.7ColumnptpClockDefaultDSPriority2read-onlycurrentThis object specifies the default Datasets clock Priority2.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.8ColumnptpClockDefaultDSSlaveOnlyread-onlycurrentWhether the SlaveOnly flag is set.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.9ColumnptpClockDefaultDSQualityClassread-onlycurrentThis object specifies the default dataset Quality Class.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.10ColumnptpClockDefaultDSQualityAccuracyread-onlycurrentThis object specifies the default dataset Quality Accuracy.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.11ColumnptpClockDefaultDSQualityOffsetread-onlycurrentThis object specifies the default dataset Quality offset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4TableptpClockRunningTablenot-accessiblecurrentTable of information about the PTP clock Running Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1RowptpClockRunningEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock running Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.1ColumnptpClockRunningDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a Logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.2ColumnptpClockRunningClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.3ColumnptpClockRunningInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.4ColumnptpClockRunningStateread-onlycurrentThis object specifies the Clock state returned by a PTP engine which was described earlier. Freerun state. Applies to a slave device that is not locked to a ma…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.5ColumnptpClockRunningPacketsSentread-onlycurrentThis object specifies the total number of all unicast and multicast packets that have been sent out for this clock in this domain for this type. These counters…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.6ColumnptpClockRunningPacketsReceivedread-onlycurrentThis object specifies the total number of all unicast and multicast packets that have been received for this clock in this domain for this type. These counters…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5TableptpClockTimePropertiesDSTablenot-accessiblecurrentTable of information about the PTP clock time properties datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1RowptpClockTimePropertiesDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock timeproperties Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.1ColumnptpClockTimePropertiesDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.2ColumnptpClockTimePropertiesDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.3ColumnptpClockTimePropertiesDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.4ColumnptpClockTimePropertiesDSCurrentUTCOffsetValidread-onlycurrentThis object specifies the timeproperties dataset value of whether the current UTC offset is valid.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.5ColumnptpClockTimePropertiesDSCurrentUTCOffsetread-onlycurrentThis object specifies the timeproperties dataset value of the current UTC offset. In PTP systems whose epoch is the PTP epoch, the value of timePropertiesDS.cu…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.6ColumnptpClockTimePropertiesDSLeap59read-onlycurrentThis object specifies the Leap59 value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.7ColumnptpClockTimePropertiesDSLeap61read-onlycurrentThis object specifies the Leap61 value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.8ColumnptpClockTimePropertiesDSTimeTraceableread-onlycurrentThis object specifies the Time Traceable value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.9ColumnptpClockTimePropertiesDSFreqTraceableread-onlycurrentThis object specifies the Frequency Traceable value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.10ColumnptpClockTimePropertiesDSPTPTimescaleread-onlycurrentThis object specifies the PTP Timescale value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.11ColumnptpClockTimePropertiesDSSourceread-onlycurrentThis object specifies the Timesource value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6TableptpClockTransDefaultDSTablenot-accessiblecurrentTable of information about the PTP Transparent clock Default Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1RowptpClockTransDefaultDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP Transparent clock Default Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.1ColumnptpClockTransDefaultDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.2ColumnptpClockTransDefaultDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.3ColumnptpClockTransDefaultDSClockIdentityread-onlycurrentThis object specifies the value of the clockIdentity attribute of the local clock.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.4ColumnptpClockTransDefaultDSNumOfPortsread-onlycurrentThis object specifies the number of PTP ports of the device. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.5ColumnptpClockTransDefaultDSDelayread-onlycurrentThis object, if the transparent clock is an end-to-end transparent clock, has the value of E2E; if the transparent clock is a peer-to-peer transparent clock, t…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.6ColumnptpClockTransDefaultDSPrimaryDomainread-onlycurrentThis object specifies the value of the primary syntonization domain. The initialization value shall be 0.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7TableptpClockPortTablenot-accessiblecurrentTable of information about the clock ports for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1RowptpClockPortEntrynot-accessiblecurrentAn entry in the table, containing information about a single clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.1ColumnptpClockPortDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.2ColumnptpClockPortClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.3ColumnptpClockPortClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.4ColumnptpClockPortTablePortNumberIndexnot-accessiblecurrentThis object specifies the PTP Portnumber for this port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.5ColumnptpClockPortNameread-onlycurrentThis object specifies the PTP clock port name configured on the node.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.6ColumnptpClockPortRoleread-onlycurrentThis object describes the current role (slave/master) of the port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.7ColumnptpClockPortSyncTwoStepread-onlycurrentThis object specifies that two-step clock operation between the PTP master and slave device is enabled.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.8ColumnptpClockPortCurrentPeerAddressTyperead-onlycurrentThis object specifies the current peer's network address type used for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.9ColumnptpClockPortCurrentPeerAddressread-onlycurrentThis object specifies the current peer's network address used for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.10ColumnptpClockPortNumOfAssociatedPortsread-onlycurrentThis object specifies - For a master port - the number of PTP slave sessions (peers) associated with this PTP port. For a slave port - the number of masters av…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8TableptpClockPortDSTablenot-accessiblecurrentTable of information about the clock ports dataset for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1RowptpClockPortDSEntrynot-accessiblecurrentAn entry in the table, containing port dataset information for a single clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.1ColumnptpClockPortDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.2ColumnptpClockPortDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.3ColumnptpClockPortDSClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.4ColumnptpClockPortDSPortNumberIndexnot-accessiblecurrentThis object specifies the PTP portnumber associated with this PTP port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.5ColumnptpClockPortDSNameread-onlycurrentThis object specifies the PTP clock port dataset name.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.6ColumnptpClockPortDSPortIdentityread-onlycurrentThis object specifies the PTP clock port Identity.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.7ColumnptpClockPortDSlogAnnouncementIntervalread-onlycurrentThis object specifies the Announce message transmission interval associated with this clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.8ColumnptpClockPortDSAnnounceRctTimeoutread-onlycurrentThis object specifies the Announce receipt timeout associated with this clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.9ColumnptpClockPortDSlogSyncIntervalread-onlycurrentThis object specifies the Sync message transmission interval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.10ColumnptpClockPortDSMinDelayReqIntervalread-onlycurrentThis object specifies the Delay_Req message transmission interval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.11ColumnptpClockPortDSPeerDelayReqIntervalread-onlycurrentThis object specifies the Pdelay_Req message transmission interval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.12ColumnptpClockPortDSDelayMechread-onlycurrentThis object specifies the delay mechanism used. If the clock is an end-to-end clock, the value of the is e2e, else if the clock is a peer to-peer clock, the va…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.13ColumnptpClockPortDSPeerMeanPathDelayread-onlycurrentThis object specifies the peer meanPathDelay.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.14ColumnptpClockPortDSGrantDurationread-onlycurrentThis object specifies the grant duration allocated by the master.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.15ColumnptpClockPortDSPTPVersionread-onlycurrentThis object specifies the PTP version being used.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9TableptpClockPortRunningTablenot-accessiblecurrentTable of information about the clock ports running datasets for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1RowptpClockPortRunningEntrynot-accessiblecurrentAn entry in the table, containing running dataset information about a single clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.1ColumnptpClockPortRunningDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.2ColumnptpClockPortRunningClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.3ColumnptpClockPortRunningClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.4ColumnptpClockPortRunningPortNumberIndexnot-accessiblecurrentThis object specifies the PTP portnumber associated with this clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.5ColumnptpClockPortRunningNameread-onlycurrentThis object specifies the PTP clock port name.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.6ColumnptpClockPortRunningStateread-onlycurrentThis object specifies the port state returned by PTP engine. initializing - In this state a port initializes its data sets, hardware, and communication facilit…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.7ColumnptpClockPortRunningRoleread-onlycurrentThis object specifies the Clock Role.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.8ColumnptpClockPortRunningInterfaceIndexread-onlycurrentThis object specifies the interface on the node being used by the PTP Clock for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.9ColumnptpClockPortRunningTransportread-onlycurrentThis object specifies the transport protocol being used for PTP communication (the mapping used).
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.10ColumnptpClockPortRunningEncapsulationTyperead-onlycurrentThis object specifies the type of encapsulation if the interface is adding extra layers (e.g., VLAN, Pseudowire encapsulation...) for the PTP messages.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.11ColumnptpClockPortRunningTxModeread-onlycurrentThis object specifies the clock transmission mode as unicast: Using unicast communication channel. multicast: Using Multicast communication channel. multicast-…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.12ColumnptpClockPortRunningRxModeread-onlycurrentThis object specifies the clock receive mode as unicast: Using unicast communication channel. multicast: Using Multicast communication channel. multicast-mix: …
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.13ColumnptpClockPortRunningPacketsReceivedread-onlycurrentThis object specifies the packets received on the clock port (cumulative). These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.14ColumnptpClockPortRunningPacketsSentread-onlycurrentThis object specifies the packets sent on the clock port (cumulative). These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10TableptpClockPortTransDSTablenot-accessiblecurrentTable of information about the Transparent clock ports running dataset for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1RowptpClockPortTransDSEntrynot-accessiblecurrentAn entry in the table, containing clock port Transparent dataset information about a single clock port
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.1ColumnptpClockPortTransDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a Logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.2ColumnptpClockPortTransDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.3ColumnptpClockPortTransDSPortNumberIndexnot-accessiblecurrentThis object specifies the PTP port number associated with this port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.4ColumnptpClockPortTransDSPortIdentityread-onlycurrentThis object specifies the value of the PortIdentity attribute of the local port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.5ColumnptpClockPortTransDSlogMinPdelayReqIntread-onlycurrentThis object specifies the value of the logarithm to the base 2 of the minPdelayReqInterval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.6ColumnptpClockPortTransDSFaultyFlagread-onlycurrentThis object specifies the value TRUE if the port is faulty and FALSE if the port is operating normally.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.7ColumnptpClockPortTransDSPeerMeanPathDelayread-onlycurrentThis object specifies, if the delayMechanism used is P2P, the value of the estimate of the current one-way propagation delay, i.e., <meanPathDelay> on the link…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11TableptpClockPortAssociateTablenot-accessiblecurrentTable of information about a given port's associated ports. For a master port: multiple slave ports that have established sessions with the current master port…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1RowptpClockPortAssociateEntrynot-accessiblecurrentAn entry in the table, containing information about a single associated port for the given clockport.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.1ColumnptpClockPortCurrentDomainIndexnot-accessiblecurrentThis object specifies the given port's domain number.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.2ColumnptpClockPortCurrentClockTypeIndexnot-accessiblecurrentThis object specifies the given port's clock type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.3ColumnptpClockPortCurrentClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.4ColumnptpClockPortCurrentPortNumberIndexnot-accessiblecurrentThis object specifies the PTP Port Number for the given port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.5ColumnptpClockPortAssociatePortIndexnot-accessiblecurrentThis object specifies the associated port's serial number in the current port's context.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.6ColumnptpClockPortAssociateAddressTyperead-onlycurrentThis object specifies the peer port's network address type used for PTP communication. The OCTET STRING representation of the OID of ptpWellKnownTransportTypes…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.7ColumnptpClockPortAssociateAddressread-onlycurrentThis object specifies the peer port's network address used for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.8ColumnptpClockPortAssociatePacketsSentread-onlycurrentThe number of packets sent to this peer port from the current port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.9ColumnptpClockPortAssociatePacketsReceivedread-onlycurrentThe number of packets received from this peer port by the current port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.10ColumnptpClockPortAssociateInErrorsread-onlycurrentThis object specifies the input errors associated with the peer port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.11ColumnptpClockPortAssociateOutErrorsread-onlycurrentThis object specifies the output errors associated with the peer port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12NodeptpWellKnownTransportTypes
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.1IdentityptpTransportTypeIPversion4currentIP version 4
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.2IdentityptpTransportTypeIPversion6currentIP version 6
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.3IdentityptpTransportTypeEthernetcurrentEthernet
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.4IdentityptpTransportTypeDeviceNETcurrentDevice NET
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.5IdentityptpTransportTypeControlNETcurrentControl NET
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.6IdentityptpTransportTypeIEC61158currentIEC61158
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13NodeptpWellKnownEncapsulationTypes
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.1IdentityptpEncapsulationTypeEthernetcurrentEthernet Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.2IdentityptpEncapsulationTypeVLANcurrentVLAN Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.3IdentityptpEncapsulationTypeUDPIPLSPcurrentUDP/IP over MPLS Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.4IdentityptpEncapsulationTypePWUDPIPLSPcurrentUDP/IP Pseudowire over MPLS Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.5IdentityptpEncapsulationTypePWEthernetLSPcurrentEthernet Pseudowire over MPLS Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.2NodeptpMIBConformance
1.3.6.1.4.1.207.8.4.4.4.504.2.1NodeptpMIBCompliances
1.3.6.1.4.1.207.8.4.4.4.504.2.1.1ComplianceptpMIBCompliancesSystemInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide system level information of clock devices. Such devices can only be m…
1.3.6.1.4.1.207.8.4.4.4.504.2.1.2ComplianceptpMIBCompliancesClockInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide clock related information. Such devices can only be monitored using t…
1.3.6.1.4.1.207.8.4.4.4.504.2.1.3ComplianceptpMIBCompliancesClockPortInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide clock port related information. Such devices can only be monitored us…
1.3.6.1.4.1.207.8.4.4.4.504.2.1.4ComplianceptpMIBCompliancesTransparentClockInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide Transparent clock related information. Such devices can only be monit…
1.3.6.1.4.1.207.8.4.4.4.504.2.2NodeptpMIBGroups
1.3.6.1.4.1.207.8.4.4.4.504.2.2.1GroupptpMIBSystemInfoGroupcurrentGroup which aggregates objects describing system-wide information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.2GroupptpMIBClockCurrentDSGroupcurrentGroup which aggregates objects describing PTP Current Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.3GroupptpMIBClockParentDSGroupcurrentGroup which aggregates objects describing PTP Parent Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.4GroupptpMIBClockDefaultDSGroupcurrentGroup which aggregates objects describing PTP Default Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.5GroupptpMIBClockRunningGroupcurrentGroup which aggregates objects describing PTP running state information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.6GroupptpMIBClockTimepropertiesGroupcurrentGroup which aggregates objects describing PTP Time Properties information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.7GroupptpMIBClockTranparentDSGroupcurrentGroup which aggregates objects describing PTP Transparent Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.8GroupptpMIBClockPortGroupcurrentGroup which aggregates objects describing information for a given PTP Port.
1.3.6.1.4.1.207.8.4.4.4.504.2.2.9GroupptpMIBClockPortDSGroupcurrentGroup which aggregates objects describing PTP Port Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.10GroupptpMIBClockPortRunningGroupcurrentGroup which aggregates objects describing PTP running interface information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.11GroupptpMIBClockPortTransDSGroupcurrentGroup which aggregates objects describing PTP TransparentDS information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.12GroupptpMIBClockPortAssociateGroupcurrentGroup which aggregates objects describing information on peer PTP ports for a given PTP clock-port.
Type Definitions
NameSyntaxStatusDescription
PtpClockDomainTypeUnsigned32 (0..255)currentThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain. The following values define the valid domains. Value De…
PtpClockIdentityOCTET STRING (SIZE (8))currentThe clock Identity is an 8-octet array and will be presented in the form of a character array. Network byte order is assumed. The value of the PtpClockIdentity should be taken from the IEEE EUI-64 individual assigned nu…
PtpClockInstanceTypeUnsigned32 (0..255)currentThe instance of the Clock of a given clock type in a given domain.
PtpClockIntervalBase2Integer32 (-128..127)currentThe interval included in message types Announce, Sync, Delay_Req, and Pdelay_Req as indicated in section 7.7.2.1 of [IEEE 1588-2008]. The mean time interval between successive messages shall be represented as the logari…
PtpClockMechanismTypeINTEGER { e2e(1), p2p(2), disabled(254) }currentThe clock type based on whether end-to-end or peer-to-peer mechanisms are used. The mechanism used to calculate the Mean Path Delay as indicated in Table 9 of [IEEE 1588-2008]. Delay mechanism Value(hex) Specification E…
PtpClockPortNumberUnsigned32 (0..65535)currentAn index identifying a specific Precision Time Protocol (PTP) port on a PTP node.
PtpClockPortStateINTEGER { initializing(1), faulty(2), disabled(3), listening(4), preMaster(5), master(6), passive(7), uncalibrated(8), slave(9) }currentThis is the value of the current state of the protocol engine associated with this port. Port state Value Description initializing 1 In this state a port initializes its data sets, hardware, and communication facilities…
PtpClockPortTransportTypeAddressOCTET STRING (SIZE (1..255))currentThe Clock port transport protocol address used for this communication between the clock nodes. This is a string corresponding to the address type as specified by the transport type used. The transport types can be defin…
PtpClockProfileTypeINTEGER { default(1), telecom(2), vendorspecific(3) }currentClock Profile used. A profile is the set of allowed Precision Time Protocol (PTP) features applicable to a device.
PtpClockQualityAccuracyTypeINTEGER { nanoSecond25(32), nanoSecond100(33), nanoSecond250(34), microSec1(35), microSec2dot5(36), microSec10(37), microSec25(38), microSec100(39), microSec250(40), milliSec1(41), milliSec2dot5(42), milliSec10(43), milliSec25(44), milliSec100(45), milliSec250(46), second1(47), second10(48), secondGreater10(49), unknown(254) }currentThe ClockQuality as specified in sections 5.3.7, 7.6.2.5 and Table 6 of [IEEE 1588-2008]. The following values are not represented in the enumerated values. 0x01-0x1F Reserved 0x32-0x7F Reserved It is important to note …
PtpClockQualityClassTypeINTEGER { clockclass6(6), clockclass7(7), clockclass13(13), clockclass14(14), clockclass52(52), clockclass58(58) }currentThe ClockQuality as specified in section 5.3.7 ClockQuality, 7.6.2.4 clockClass and Table 5 clockClass specifications of [IEEE 1588-2008]. Value Description 0 Reserved to enable compatibility with future versions. 1-5 R…
PtpClockRoleTypeINTEGER { master(1), slave(2) }currentThe Clock Role. The protocol generates a Master Slave relationship among the clocks in the system. Clock Role Value Description Master clock 1 A clock that is the source of time to which all other clocks on that path sy…
PtpClockStateTypeINTEGER { freerun(1), holdover(2), acquiring(3), frequencyLocked(4), phaseAligned(5) }currentThe clock state returned by a PTP engine. Clock State Value Description Freerun state 1 Applies to a slave device that is not locked to a master. This is the initial state a slave starts out with when it is not getting …
PtpClockTimeIntervalOCTET STRING (SIZE (1..255))currentThis textual convention corresponds to the TimeInterval structure indicated in section 5.3.2 of [IEEE 1588-2008]. It will be presented in the form of a character array. Network byte order is assumed. The TimeInterval ty…
PtpClockTimeSourceTypeINTEGER { atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handSet(96), other(144), internalOscillator(160) }currentThe ClockQuality as specified in Sections 5.3.7, 7.6.2.6 and Table 7 of [IEEE 1588-2008]. The following values are not represented in the enumerated values. 0xF0-0xFE For use by alternate PTP profiles 0xFF Reserved It i…
PtpClockTxModeTypeINTEGER { unicast(1), multicast(2), multicastmix(3) }currentTransmission mode. Unicast: Using unicast communication channel. Multicast: Using Multicast communication channel. multicast-mix: Using multicast-unicast communication channel
PtpClockTypeINTEGER { ordinaryClock(1), boundaryClock(2), transparentClock(3), boundaryNode(4) }currentThe clock types as defined in the MIB module description.