MIB Viewer

AT-PTP-MIB

196 objects
This MIB file contains definitions of managed objects for the IEEE 1588v2 Precision Time Protocol (PTP) module.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.207.8.4.4.4.504IdentityatPtpMIBThis MIB file contains definitions of managed objects for the IEEE 1588v2 Precision Time Protocol (PTP) module.
1.3.6.1.4.1.207.8.4.4.4.504.0NodeptpMIBNotifs
1.3.6.1.4.1.207.8.4.4.4.504.1NodeptpMIBObjects
1.3.6.1.4.1.207.8.4.4.4.504.1.1NodeptpMIBSystemInfo
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1TableptpSystemTablenot-accessiblecurrentTable of count information about the PTP system for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1RowptpSystemEntrynot-accessiblecurrentAn entry in the table, containing count information about a single domain. New row entries are added when the PTP clock for this domain is configured, while th…
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1.1ColumnptpDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices. The Clock Domain is a logical group of clocks and devices that synchroni…
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1.2ColumnptpInstanceIndexnot-accessiblecurrentThis object specifies the instance of the Clock for this domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.1.1.3ColumnptpDomainClockPortsTotalread-onlycurrentThis object specifies the total number of clock ports configured within a domain in the system.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2TableptpSystemDomainTablenot-accessiblecurrent
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2.1RowptpSystemDomainEntrynot-accessiblecurrentAn entry in the table, containing information about a single clock mode for the PTP system. A row entry gets added when PTP clocks are configured on the node.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2.1.1ColumnptpSystemDomainClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.2.1.2ColumnptpSystemDomainTotalsread-onlycurrentThis object specifies the total number of PTP domains for this particular clock type configured in this node.
1.3.6.1.4.1.207.8.4.4.4.504.1.1.3ScalarptpSystemProfileread-onlycurrentThis object specifies the PTP Profile implemented on the system.
1.3.6.1.4.1.207.8.4.4.4.504.1.2NodeptpMIBClockInfo
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1TableptpClockCurrentDSTablenot-accessiblecurrentTable of information about the PTP clock Current Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1RowptpClockCurrentDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock Current Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.1ColumnptpClockCurrentDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.2ColumnptpClockCurrentDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.3ColumnptpClockCurrentDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.4ColumnptpClockCurrentDSStepsRemovedread-onlycurrentThe current clock dataset StepsRemoved value. This object specifies the distance measured by the number of Boundary clocks between the local clock and the Fore…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.5ColumnptpClockCurrentDSOffsetFromMasterread-onlycurrentThis object specifies the current clock dataset ClockOffset value. The value of the computation of the offset in time between a slave and a master clock.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.1.1.6ColumnptpClockCurrentDSMeanPathDelayread-onlycurrentThis object specifies the current clock dataset MeanPathDelay value. The mean path delay between a pair of ports as measured by the delay request-response mech…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2TableptpClockParentDSTablenot-accessiblecurrentTable of information about the PTP clock Parent Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1RowptpClockParentDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock Parent Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.1ColumnptpClockParentDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.2ColumnptpClockParentDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.3ColumnptpClockParentDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.4ColumnptpClockParentDSParentPortIdentityread-onlycurrentThis object specifies the value of portIdentity of the port on the master that issues the Sync messages used in synchronizing this clock.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.5ColumnptpClockParentDSParentStatsread-onlycurrentThis object specifies the Parent Dataset ParentStats value. This value indicates whether the values of ParentDSOffset and ParentDSClockPhChRate have been measu…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.6ColumnptpClockParentDSOffsetread-onlycurrentThis object specifies the Parent Dataset ParentOffsetScaledLogVariance value. This value is the variance of the parent clock's phase as measured by the local c…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.7ColumnptpClockParentDSClockPhChRateread-onlycurrentThis object specifies the clock's parent dataset ParentClockPhaseChangeRate value. This value is an estimate of the parent clock's phase change rate as measure…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.8ColumnptpClockParentDSGMClockIdentityread-onlycurrentThis object specifies the parent dataset Grandmaster clock identity.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.9ColumnptpClockParentDSGMClockPriority1read-onlycurrentThis object specifies the parent dataset Grandmaster clock priority1.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.10ColumnptpClockParentDSGMClockPriority2read-onlycurrentThis object specifies the parent dataset grandmaster clock priority2.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.11ColumnptpClockParentDSGMClockQualityClassread-onlycurrentThis object specifies the parent dataset grandmaster clock quality class.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.12ColumnptpClockParentDSGMClockQualityAccuracyread-onlycurrentThis object specifies the parent dataset grandmaster clock quality accuracy.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.2.1.13ColumnptpClockParentDSGMClockQualityOffsetread-onlycurrentThis object specifies the parent dataset grandmaster clock quality offset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3TableptpClockDefaultDSTablenot-accessiblecurrentTable of information about the PTP clock Default Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1RowptpClockDefaultDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock Default Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.1ColumnptpClockDefaultDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.2ColumnptpClockDefaultDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.3ColumnptpClockDefaultDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.4ColumnptpClockDefaultDSTwoStepFlagread-onlycurrentThis object specifies whether the Two Step process is used.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.5ColumnptpClockDefaultDSClockIdentityread-onlycurrentThis object specifies the default Datasets clock identity.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.6ColumnptpClockDefaultDSPriority1read-onlycurrentThis object specifies the default Datasets clock Priority1.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.7ColumnptpClockDefaultDSPriority2read-onlycurrentThis object specifies the default Datasets clock Priority2.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.8ColumnptpClockDefaultDSSlaveOnlyread-onlycurrentWhether the SlaveOnly flag is set.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.9ColumnptpClockDefaultDSQualityClassread-onlycurrentThis object specifies the default dataset Quality Class.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.10ColumnptpClockDefaultDSQualityAccuracyread-onlycurrentThis object specifies the default dataset Quality Accuracy.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.3.1.11ColumnptpClockDefaultDSQualityOffsetread-onlycurrentThis object specifies the default dataset Quality offset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4TableptpClockRunningTablenot-accessiblecurrentTable of information about the PTP clock Running Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1RowptpClockRunningEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock running Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.1ColumnptpClockRunningDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a Logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.2ColumnptpClockRunningClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.3ColumnptpClockRunningInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.4ColumnptpClockRunningStateread-onlycurrentThis object specifies the Clock state returned by a PTP engine which was described earlier. Freerun state. Applies to a slave device that is not locked to a ma…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.5ColumnptpClockRunningPacketsSentread-onlycurrentThis object specifies the total number of all unicast and multicast packets that have been sent out for this clock in this domain for this type. These counters…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.4.1.6ColumnptpClockRunningPacketsReceivedread-onlycurrentThis object specifies the total number of all unicast and multicast packets that have been received for this clock in this domain for this type. These counters…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5TableptpClockTimePropertiesDSTablenot-accessiblecurrentTable of information about the PTP clock time properties datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1RowptpClockTimePropertiesDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP clock timeproperties Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.1ColumnptpClockTimePropertiesDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.2ColumnptpClockTimePropertiesDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.3ColumnptpClockTimePropertiesDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.4ColumnptpClockTimePropertiesDSCurrentUTCOffsetValidread-onlycurrentThis object specifies the timeproperties dataset value of whether the current UTC offset is valid.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.5ColumnptpClockTimePropertiesDSCurrentUTCOffsetread-onlycurrentThis object specifies the timeproperties dataset value of the current UTC offset. In PTP systems whose epoch is the PTP epoch, the value of timePropertiesDS.cu…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.6ColumnptpClockTimePropertiesDSLeap59read-onlycurrentThis object specifies the Leap59 value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.7ColumnptpClockTimePropertiesDSLeap61read-onlycurrentThis object specifies the Leap61 value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.8ColumnptpClockTimePropertiesDSTimeTraceableread-onlycurrentThis object specifies the Time Traceable value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.9ColumnptpClockTimePropertiesDSFreqTraceableread-onlycurrentThis object specifies the Frequency Traceable value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.10ColumnptpClockTimePropertiesDSPTPTimescaleread-onlycurrentThis object specifies the PTP Timescale value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.5.1.11ColumnptpClockTimePropertiesDSSourceread-onlycurrentThis object specifies the Timesource value in the clock Current Dataset.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6TableptpClockTransDefaultDSTablenot-accessiblecurrentTable of information about the PTP Transparent clock Default Datasets for all domains.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1RowptpClockTransDefaultDSEntrynot-accessiblecurrentAn entry in the table, containing information about a single PTP Transparent clock Default Datasets for a domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.1ColumnptpClockTransDefaultDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.2ColumnptpClockTransDefaultDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.3ColumnptpClockTransDefaultDSClockIdentityread-onlycurrentThis object specifies the value of the clockIdentity attribute of the local clock.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.4ColumnptpClockTransDefaultDSNumOfPortsread-onlycurrentThis object specifies the number of PTP ports of the device. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.5ColumnptpClockTransDefaultDSDelayread-onlycurrentThis object, if the transparent clock is an end-to-end transparent clock, has the value of E2E; if the transparent clock is a peer-to-peer transparent clock, t…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.6.1.6ColumnptpClockTransDefaultDSPrimaryDomainread-onlycurrentThis object specifies the value of the primary syntonization domain. The initialization value shall be 0.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7TableptpClockPortTablenot-accessiblecurrentTable of information about the clock ports for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1RowptpClockPortEntrynot-accessiblecurrentAn entry in the table, containing information about a single clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.1ColumnptpClockPortDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.2ColumnptpClockPortClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.3ColumnptpClockPortClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.4ColumnptpClockPortTablePortNumberIndexnot-accessiblecurrentThis object specifies the PTP Portnumber for this port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.5ColumnptpClockPortNameread-onlycurrentThis object specifies the PTP clock port name configured on the node.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.6ColumnptpClockPortRoleread-onlycurrentThis object describes the current role (slave/master) of the port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.7ColumnptpClockPortSyncTwoStepread-onlycurrentThis object specifies that two-step clock operation between the PTP master and slave device is enabled.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.8ColumnptpClockPortCurrentPeerAddressTyperead-onlycurrentThis object specifies the current peer's network address type used for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.9ColumnptpClockPortCurrentPeerAddressread-onlycurrentThis object specifies the current peer's network address used for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.7.1.10ColumnptpClockPortNumOfAssociatedPortsread-onlycurrentThis object specifies - For a master port - the number of PTP slave sessions (peers) associated with this PTP port. For a slave port - the number of masters av…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8TableptpClockPortDSTablenot-accessiblecurrentTable of information about the clock ports dataset for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1RowptpClockPortDSEntrynot-accessiblecurrentAn entry in the table, containing port dataset information for a single clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.1ColumnptpClockPortDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.2ColumnptpClockPortDSClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.3ColumnptpClockPortDSClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.4ColumnptpClockPortDSPortNumberIndexnot-accessiblecurrentThis object specifies the PTP portnumber associated with this PTP port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.5ColumnptpClockPortDSNameread-onlycurrentThis object specifies the PTP clock port dataset name.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.6ColumnptpClockPortDSPortIdentityread-onlycurrentThis object specifies the PTP clock port Identity.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.7ColumnptpClockPortDSlogAnnouncementIntervalread-onlycurrentThis object specifies the Announce message transmission interval associated with this clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.8ColumnptpClockPortDSAnnounceRctTimeoutread-onlycurrentThis object specifies the Announce receipt timeout associated with this clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.9ColumnptpClockPortDSlogSyncIntervalread-onlycurrentThis object specifies the Sync message transmission interval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.10ColumnptpClockPortDSMinDelayReqIntervalread-onlycurrentThis object specifies the Delay_Req message transmission interval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.11ColumnptpClockPortDSPeerDelayReqIntervalread-onlycurrentThis object specifies the Pdelay_Req message transmission interval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.12ColumnptpClockPortDSDelayMechread-onlycurrentThis object specifies the delay mechanism used. If the clock is an end-to-end clock, the value of the is e2e, else if the clock is a peer to-peer clock, the va…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.13ColumnptpClockPortDSPeerMeanPathDelayread-onlycurrentThis object specifies the peer meanPathDelay.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.14ColumnptpClockPortDSGrantDurationread-onlycurrentThis object specifies the grant duration allocated by the master.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.8.1.15ColumnptpClockPortDSPTPVersionread-onlycurrentThis object specifies the PTP version being used.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9TableptpClockPortRunningTablenot-accessiblecurrentTable of information about the clock ports running datasets for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1RowptpClockPortRunningEntrynot-accessiblecurrentAn entry in the table, containing running dataset information about a single clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.1ColumnptpClockPortRunningDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.2ColumnptpClockPortRunningClockTypeIndexnot-accessiblecurrentThis object specifies the clock type as defined in the Textual convention description.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.3ColumnptpClockPortRunningClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.4ColumnptpClockPortRunningPortNumberIndexnot-accessiblecurrentThis object specifies the PTP portnumber associated with this clock port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.5ColumnptpClockPortRunningNameread-onlycurrentThis object specifies the PTP clock port name.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.6ColumnptpClockPortRunningStateread-onlycurrentThis object specifies the port state returned by PTP engine. initializing - In this state a port initializes its data sets, hardware, and communication facilit…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.7ColumnptpClockPortRunningRoleread-onlycurrentThis object specifies the Clock Role.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.8ColumnptpClockPortRunningInterfaceIndexread-onlycurrentThis object specifies the interface on the node being used by the PTP Clock for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.9ColumnptpClockPortRunningTransportread-onlycurrentThis object specifies the transport protocol being used for PTP communication (the mapping used).
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.10ColumnptpClockPortRunningEncapsulationTyperead-onlycurrentThis object specifies the type of encapsulation if the interface is adding extra layers (e.g., VLAN, Pseudowire encapsulation...) for the PTP messages.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.11ColumnptpClockPortRunningTxModeread-onlycurrentThis object specifies the clock transmission mode as unicast: Using unicast communication channel. multicast: Using Multicast communication channel. multicast-…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.12ColumnptpClockPortRunningRxModeread-onlycurrentThis object specifies the clock receive mode as unicast: Using unicast communication channel. multicast: Using Multicast communication channel. multicast-mix: …
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.13ColumnptpClockPortRunningPacketsReceivedread-onlycurrentThis object specifies the packets received on the clock port (cumulative). These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.9.1.14ColumnptpClockPortRunningPacketsSentread-onlycurrentThis object specifies the packets sent on the clock port (cumulative). These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10TableptpClockPortTransDSTablenot-accessiblecurrentTable of information about the Transparent clock ports running dataset for a particular domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1RowptpClockPortTransDSEntrynot-accessiblecurrentAn entry in the table, containing clock port Transparent dataset information about a single clock port
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.1ColumnptpClockPortTransDSDomainIndexnot-accessiblecurrentThis object specifies the domain number used to create a Logical group of PTP devices.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.2ColumnptpClockPortTransDSInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.3ColumnptpClockPortTransDSPortNumberIndexnot-accessiblecurrentThis object specifies the PTP port number associated with this port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.4ColumnptpClockPortTransDSPortIdentityread-onlycurrentThis object specifies the value of the PortIdentity attribute of the local port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.5ColumnptpClockPortTransDSlogMinPdelayReqIntread-onlycurrentThis object specifies the value of the logarithm to the base 2 of the minPdelayReqInterval.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.6ColumnptpClockPortTransDSFaultyFlagread-onlycurrentThis object specifies the value TRUE if the port is faulty and FALSE if the port is operating normally.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.10.1.7ColumnptpClockPortTransDSPeerMeanPathDelayread-onlycurrentThis object specifies, if the delayMechanism used is P2P, the value of the estimate of the current one-way propagation delay, i.e., <meanPathDelay> on the link…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11TableptpClockPortAssociateTablenot-accessiblecurrentTable of information about a given port's associated ports. For a master port: multiple slave ports that have established sessions with the current master port…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1RowptpClockPortAssociateEntrynot-accessiblecurrentAn entry in the table, containing information about a single associated port for the given clockport.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.1ColumnptpClockPortCurrentDomainIndexnot-accessiblecurrentThis object specifies the given port's domain number.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.2ColumnptpClockPortCurrentClockTypeIndexnot-accessiblecurrentThis object specifies the given port's clock type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.3ColumnptpClockPortCurrentClockInstanceIndexnot-accessiblecurrentThis object specifies the instance of the clock for this clock type in the given domain.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.4ColumnptpClockPortCurrentPortNumberIndexnot-accessiblecurrentThis object specifies the PTP Port Number for the given port.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.5ColumnptpClockPortAssociatePortIndexnot-accessiblecurrentThis object specifies the associated port's serial number in the current port's context.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.6ColumnptpClockPortAssociateAddressTyperead-onlycurrentThis object specifies the peer port's network address type used for PTP communication. The OCTET STRING representation of the OID of ptpWellKnownTransportTypes…
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.7ColumnptpClockPortAssociateAddressread-onlycurrentThis object specifies the peer port's network address used for PTP communication.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.8ColumnptpClockPortAssociatePacketsSentread-onlycurrentThe number of packets sent to this peer port from the current port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.9ColumnptpClockPortAssociatePacketsReceivedread-onlycurrentThe number of packets received from this peer port by the current port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.10ColumnptpClockPortAssociateInErrorsread-onlycurrentThis object specifies the input errors associated with the peer port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.11.1.11ColumnptpClockPortAssociateOutErrorsread-onlycurrentThis object specifies the output errors associated with the peer port. These counters are discontinuous.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12NodeptpWellKnownTransportTypes
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.1IdentityptpTransportTypeIPversion4currentIP version 4
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.2IdentityptpTransportTypeIPversion6currentIP version 6
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.3IdentityptpTransportTypeEthernetcurrentEthernet
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.4IdentityptpTransportTypeDeviceNETcurrentDevice NET
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.5IdentityptpTransportTypeControlNETcurrentControl NET
1.3.6.1.4.1.207.8.4.4.4.504.1.2.12.6IdentityptpTransportTypeIEC61158currentIEC61158
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13NodeptpWellKnownEncapsulationTypes
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.1IdentityptpEncapsulationTypeEthernetcurrentEthernet Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.2IdentityptpEncapsulationTypeVLANcurrentVLAN Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.3IdentityptpEncapsulationTypeUDPIPLSPcurrentUDP/IP over MPLS Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.4IdentityptpEncapsulationTypePWUDPIPLSPcurrentUDP/IP Pseudowire over MPLS Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.1.2.13.5IdentityptpEncapsulationTypePWEthernetLSPcurrentEthernet Pseudowire over MPLS Encapsulation type.
1.3.6.1.4.1.207.8.4.4.4.504.2NodeptpMIBConformance
1.3.6.1.4.1.207.8.4.4.4.504.2.1NodeptpMIBCompliances
1.3.6.1.4.1.207.8.4.4.4.504.2.1.1ComplianceptpMIBCompliancesSystemInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide system level information of clock devices. Such devices can only be m…
1.3.6.1.4.1.207.8.4.4.4.504.2.1.2ComplianceptpMIBCompliancesClockInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide clock related information. Such devices can only be monitored using t…
1.3.6.1.4.1.207.8.4.4.4.504.2.1.3ComplianceptpMIBCompliancesClockPortInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide clock port related information. Such devices can only be monitored us…
1.3.6.1.4.1.207.8.4.4.4.504.2.1.4ComplianceptpMIBCompliancesTransparentClockInfocurrentCompliance statement for agents that provide read-only support for PTPBASE-MIB to provide Transparent clock related information. Such devices can only be monit…
1.3.6.1.4.1.207.8.4.4.4.504.2.2NodeptpMIBGroups
1.3.6.1.4.1.207.8.4.4.4.504.2.2.1GroupptpMIBSystemInfoGroupcurrentGroup which aggregates objects describing system-wide information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.2GroupptpMIBClockCurrentDSGroupcurrentGroup which aggregates objects describing PTP Current Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.3GroupptpMIBClockParentDSGroupcurrentGroup which aggregates objects describing PTP Parent Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.4GroupptpMIBClockDefaultDSGroupcurrentGroup which aggregates objects describing PTP Default Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.5GroupptpMIBClockRunningGroupcurrentGroup which aggregates objects describing PTP running state information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.6GroupptpMIBClockTimepropertiesGroupcurrentGroup which aggregates objects describing PTP Time Properties information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.7GroupptpMIBClockTranparentDSGroupcurrentGroup which aggregates objects describing PTP Transparent Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.8GroupptpMIBClockPortGroupcurrentGroup which aggregates objects describing information for a given PTP Port.
1.3.6.1.4.1.207.8.4.4.4.504.2.2.9GroupptpMIBClockPortDSGroupcurrentGroup which aggregates objects describing PTP Port Dataset information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.10GroupptpMIBClockPortRunningGroupcurrentGroup which aggregates objects describing PTP running interface information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.11GroupptpMIBClockPortTransDSGroupcurrentGroup which aggregates objects describing PTP TransparentDS information
1.3.6.1.4.1.207.8.4.4.4.504.2.2.12GroupptpMIBClockPortAssociateGroupcurrentGroup which aggregates objects describing information on peer PTP ports for a given PTP clock-port.
Type Definitions
NameSyntaxStatusDescription
PtpClockDomainTypeUnsigned32 (0..255)currentThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain. The following values define the valid domains. Value De…
PtpClockIdentityOCTET STRING (SIZE (8))currentThe clock Identity is an 8-octet array and will be presented in the form of a character array. Network byte order is assumed. The value of the PtpClockIdentity should be taken from the IEEE EUI-64 individual assigned nu…
PtpClockInstanceTypeUnsigned32 (0..255)currentThe instance of the Clock of a given clock type in a given domain.
PtpClockIntervalBase2Integer32 (-128..127)currentThe interval included in message types Announce, Sync, Delay_Req, and Pdelay_Req as indicated in section 7.7.2.1 of [IEEE 1588-2008]. The mean time interval between successive messages shall be represented as the logari…
PtpClockMechanismTypeINTEGER { e2e(1), p2p(2), disabled(254) }currentThe clock type based on whether end-to-end or peer-to-peer mechanisms are used. The mechanism used to calculate the Mean Path Delay as indicated in Table 9 of [IEEE 1588-2008]. Delay mechanism Value(hex) Specification E…
PtpClockPortNumberUnsigned32 (0..65535)currentAn index identifying a specific Precision Time Protocol (PTP) port on a PTP node.
PtpClockPortStateINTEGER { initializing(1), faulty(2), disabled(3), listening(4), preMaster(5), master(6), passive(7), uncalibrated(8), slave(9) }currentThis is the value of the current state of the protocol engine associated with this port. Port state Value Description initializing 1 In this state a port initializes its data sets, hardware, and communication facilities…
PtpClockPortTransportTypeAddressOCTET STRING (SIZE (1..255))currentThe Clock port transport protocol address used for this communication between the clock nodes. This is a string corresponding to the address type as specified by the transport type used. The transport types can be defin…
PtpClockProfileTypeINTEGER { default(1), telecom(2), vendorspecific(3) }currentClock Profile used. A profile is the set of allowed Precision Time Protocol (PTP) features applicable to a device.
PtpClockQualityAccuracyTypeINTEGER { nanoSecond25(32), nanoSecond100(33), nanoSecond250(34), microSec1(35), microSec2dot5(36), microSec10(37), microSec25(38), microSec100(39), microSec250(40), milliSec1(41), milliSec2dot5(42), milliSec10(43), milliSec25(44), milliSec100(45), milliSec250(46), second1(47), second10(48), secondGreater10(49), unknown(254) }currentThe ClockQuality as specified in sections 5.3.7, 7.6.2.5 and Table 6 of [IEEE 1588-2008]. The following values are not represented in the enumerated values. 0x01-0x1F Reserved 0x32-0x7F Reserved It is important to note …
PtpClockQualityClassTypeINTEGER { clockclass6(6), clockclass7(7), clockclass13(13), clockclass14(14), clockclass52(52), clockclass58(58) }currentThe ClockQuality as specified in section 5.3.7 ClockQuality, 7.6.2.4 clockClass and Table 5 clockClass specifications of [IEEE 1588-2008]. Value Description 0 Reserved to enable compatibility with future versions. 1-5 R…
PtpClockRoleTypeINTEGER { master(1), slave(2) }currentThe Clock Role. The protocol generates a Master Slave relationship among the clocks in the system. Clock Role Value Description Master clock 1 A clock that is the source of time to which all other clocks on that path sy…
PtpClockStateTypeINTEGER { freerun(1), holdover(2), acquiring(3), frequencyLocked(4), phaseAligned(5) }currentThe clock state returned by a PTP engine. Clock State Value Description Freerun state 1 Applies to a slave device that is not locked to a master. This is the initial state a slave starts out with when it is not getting …
PtpClockTimeIntervalOCTET STRING (SIZE (1..255))currentThis textual convention corresponds to the TimeInterval structure indicated in section 5.3.2 of [IEEE 1588-2008]. It will be presented in the form of a character array. Network byte order is assumed. The TimeInterval ty…
PtpClockTimeSourceTypeINTEGER { atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handSet(96), other(144), internalOscillator(160) }currentThe ClockQuality as specified in Sections 5.3.7, 7.6.2.6 and Table 7 of [IEEE 1588-2008]. The following values are not represented in the enumerated values. 0xF0-0xFE For use by alternate PTP profiles 0xFF Reserved It i…
PtpClockTxModeTypeINTEGER { unicast(1), multicast(2), multicastmix(3) }currentTransmission mode. Unicast: Using unicast communication channel. Multicast: Using Multicast communication channel. multicast-mix: Using multicast-unicast communication channel
PtpClockTypeINTEGER { ordinaryClock(1), boundaryClock(2), transparentClock(3), boundaryNode(4) }currentThe clock types as defined in the MIB module description.