MIB Viewer

AT-SYSINFO-MIB

98 objects
Subtree beneath which system inforamtion ids are assigned. It contains generic system information, as follows: { sysinfo 1 } fanAndPs { sysinfo 2 } restartGroup { sysinfo 3 } cpu { sysinfo 4 } sysTemperature { sysinfo 5 } atrContactDetails { sysinfo 6 } bbrNvs { sysinfo 9 } hostId { sysinfo 10 } envMon { sysinfo 11 } xem { sysinfo 12 } awpEnvMon { sysinfo 13 } awpStack { sysinfo 14 } atPortInfo
OIDNameAccessStatusDescription
1.3.6.1.4.1.207.8.4.4.3IdentitysysinfoSubtree beneath which system inforamtion ids are assigned. It contains generic system information, as follows: { sysinfo 1 } fanAndPs { sysinfo 2 } restartGrou…
1.3.6.1.4.1.207.8.4.4.3.1NodefanAndPs
1.3.6.1.4.1.207.8.4.4.3.1.0NodefanAndPsTrap
1.3.6.1.4.1.207.8.4.4.3.1.0.1NotificationfanAndPsRpsConnectionTrapcurrentGenerated when the RPS connection status changes.
1.3.6.1.4.1.207.8.4.4.3.1.0.2NotificationfanAndPsMainPSUStatusTrapcurrentGenerated when the main power supply status changes.
1.3.6.1.4.1.207.8.4.4.3.1.0.3NotificationfanAndPsRedundantPSUStatusTrapcurrentGenerated when the RPS status changes.
1.3.6.1.4.1.207.8.4.4.3.1.0.4NotificationfanAndPsMainFanStatusTrapcurrentGenerated when the main fan changes status.
1.3.6.1.4.1.207.8.4.4.3.1.0.5NotificationfanAndPsRedundantFanStatusTrapcurrentGenerated when the redundant fan changes status.
1.3.6.1.4.1.207.8.4.4.3.1.0.6NotificationfanAndPsTemperatureStatusTrapcurrentGenerated when the temperature changes status.
1.3.6.1.4.1.207.8.4.4.3.1.0.7NotificationfanAndPsFanTrayPresentTrapcurrentGenerated when the fan tray presence status changes.
1.3.6.1.4.1.207.8.4.4.3.1.0.8NotificationfanAndPsFanTrayStatusTrapcurrentGenerated when the fan tray status changes.
1.3.6.1.4.1.207.8.4.4.3.1.0.9NotificationfanAndPsMainMonitoringStatusTrapcurrentGenerated when the main power supply monitoring status changes.
1.3.6.1.4.1.207.8.4.4.3.1.0.10NotificationfanAndPsAccelFanStatusTrapcurrentGenerated when the accelerator fans' status changes.
1.3.6.1.4.1.207.8.4.4.3.1.1ScalarfanAndPsRpsConnectionStatusread-onlycurrentThe status of the Redundant Power Supply (RPS) connection, ie, whether an RPS is actually connected or not, regardless of whether the RPS is on or not. notSupp…
1.3.6.1.4.1.207.8.4.4.3.1.2ScalarfanAndPsMainPSUStatusread-onlycurrentThe status of the main Power Supply. on means that the power supply is present and fully operational. off means that the power supply is totally off (and obvio…
1.3.6.1.4.1.207.8.4.4.3.1.3ScalarfanAndPsRedundantPSUStatusread-onlycurrentThe status of the redundant Power Supply. notSupported means this device does not support redundant power supplies, on means that the redundant power supply is…
1.3.6.1.4.1.207.8.4.4.3.1.4ScalarfanAndPsRpsMonitoringStatusread-writecurrentThe current status of redundant power supply monitoring. The monitoring of the redundant power supply and its fan must be enabled by command or by setting this…
1.3.6.1.4.1.207.8.4.4.3.1.5ScalarfanAndPsMainFanStatusread-onlycurrentThe status of the main Power Supply fan. notSupported means that this device does not support monitoring on the main power supply fan, or that there is no main…
1.3.6.1.4.1.207.8.4.4.3.1.6ScalarfanAndPsRedundantFanStatusread-onlycurrentThe status of the redundant Power Supply Fan. notSupported means this device does not support redundant power supplies, ok means that the redundant power suppl…
1.3.6.1.4.1.207.8.4.4.3.1.7ScalarfanAndPsTemperatureStatusread-onlycurrentThe status of temperature in this device. ok means that the device is not capable of monitoring temperature or that the temperature is OK, notOk means that the…
1.3.6.1.4.1.207.8.4.4.3.1.8ScalarfanAndPsFanTrayPresentread-onlycurrentThe status of the presence of the fan tray in this system. Systems which do not support a fan tray return the value notSupported. Upon removal of the fan tray …
1.3.6.1.4.1.207.8.4.4.3.1.9ScalarfanAndPsFanTrayStatusread-onlycurrentThe status of the fan tray in this system. Systems which do not support a fan tray return the value notSupported. The value ok is returned if all fans in the f…
1.3.6.1.4.1.207.8.4.4.3.1.10ScalarfanAndPsMainMonitoringStatusread-onlycurrentThe current status of main power supply monitoring. The monitoring of the main power supply and its fan is always enabled by those systems that support it. Sys…
1.3.6.1.4.1.207.8.4.4.3.1.11TablefanAndPsPsuStatusTablenot-accessiblecurrentThe table of AT8948 fanAndPsPsuStatusTable. Each entry in the table represents the status of one of the power supplies in AT8948 system. Each power supply has …
1.3.6.1.4.1.207.8.4.4.3.1.11.1RowfanAndPsPsuStatusEntrynot-accessiblecurrentA single entry of AT8948 fanAndPsPsuStatusTable, indexed by fanAndPsPsuNumber field.
1.3.6.1.4.1.207.8.4.4.3.1.11.1.1ColumnfanAndPsPsuNumberread-onlycurrentThe PSU board identity for which this entry holds. If the system consists only of a single PSU board, only one entry will appear in the table, whose index is 1.
1.3.6.1.4.1.207.8.4.4.3.1.11.1.2ColumnfanAndPsPsuPresentread-onlycurrentThe PSU present state, displayed as 'yes' if present, or 'no' if absent.
1.3.6.1.4.1.207.8.4.4.3.1.11.1.3ColumnfanAndPsPsuTyperead-onlycurrentThe PSU type, displayed as AC, or DC, or FAN, or NOT PRESENT.
1.3.6.1.4.1.207.8.4.4.3.1.11.1.4ColumnfanAndPsPsuFanread-onlycurrentThe PSU fan status, displayed as OK, or FAIL, or NOT PRESENT.
1.3.6.1.4.1.207.8.4.4.3.1.11.1.5ColumnfanAndPsPsuTemperatureread-onlycurrentThe PSU temperature, displayed as GOOD, or HIGH, or NOT PRESENT, or NOT SUPPORTED.
1.3.6.1.4.1.207.8.4.4.3.1.11.1.6ColumnfanAndPsPsuPowerread-onlycurrentThe PSU power status, displayed as GOOD, or BAD, or NOT PRESENT or NOT SUPPORTED.
1.3.6.1.4.1.207.8.4.4.3.1.12ScalarfanAndPsAccelFanStatusread-onlycurrentThe status of the accelerator card fans. Non-supported means this device does not support monitoring of the accelerator card fans.
1.3.6.1.4.1.207.8.4.4.3.2NoderestartGroup
1.3.6.1.4.1.207.8.4.4.3.2.1Scalarrestartread-writecurrentA router/switch restart request. A management station can remotely instruct an ATI router/switch to action a warm or cold restart. Once all the appropriate int…
1.3.6.1.4.1.207.8.4.4.3.2.2ScalarrestartCauseread-onlycurrentThe reason for last time restart.
1.3.6.1.4.1.207.8.4.4.3.2.3ScalarrestartLogread-onlycurrentThe restart logging details.
1.3.6.1.4.1.207.8.4.4.3.2.11NotificationrestartNotificationcurrentA restart notification is a trap sent to tell snmp managers the reason of restarting
1.3.6.1.4.1.207.8.4.4.3.3Nodecpu
1.3.6.1.4.1.207.8.4.4.3.3.1ScalarcpuUtilisationMaxread-onlycurrentMaximum CPU utilisation since the router was last restarted. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.2ScalarcpuUtilisationAvgread-onlycurrentAverage CPU utilisation since the router was last restarted. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.3ScalarcpuUtilisationAvgLastMinuteread-onlycurrentAverage CPU utilisation over the past minute. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.4ScalarcpuUtilisationAvgLast10Secondsread-onlycurrentAverage CPU utilisation over the past ten seconds. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.5ScalarcpuUtilisationAvgLastSecondread-onlycurrentAverage CPU utilisation over the past second. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.6ScalarcpuUtilisationMaxLast5Minutesread-onlycurrentMaximum CPU utilisation over the last 5 minutes. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.7ScalarcpuUtilisationAvgLast5Minutesread-onlycurrentAverage CPU utilisation over the past 5 minutes. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.8TablecpuUtilisationStackTablenot-accessiblecurrentA list of stack members. For a chassis switch, this is a list of cards.
1.3.6.1.4.1.207.8.4.4.3.3.8.1RowcpuUtilisationStackEntrynot-accessiblecurrentA set of parameters that describe the CPU utilisation of a stack member. For a chassis switch, it corresponds to the CPU utilisation of a card.
1.3.6.1.4.1.207.8.4.4.3.3.8.1.1ColumncpuUtilisationStackIdread-onlycurrentStack member ID. For a chassis switch, it corresponds to the card ID. For VCStack Plus, 1-12 refers to the cards on VCS stack member 1 and 13-24 refers to the …
1.3.6.1.4.1.207.8.4.4.3.3.8.1.2ColumncpuUtilisationStackMaxread-onlycurrentMaximum CPU utilisation since the router was last restarted. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.8.1.3ColumncpuUtilisationStackAvgread-onlycurrentAverage CPU utilisation since the router was last restarted. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.8.1.4ColumncpuUtilisationStackAvgLastMinuteread-onlycurrentAverage CPU utilisation over the past minute. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.8.1.5ColumncpuUtilisationStackAvgLast10Secondsread-onlycurrentAverage CPU utilisation over the past ten seconds. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.8.1.6ColumncpuUtilisationStackAvgLastSecondread-onlycurrentAverage CPU utilisation over the past second. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.8.1.7ColumncpuUtilisationStackMaxLast5Minutesread-onlycurrentMaximum CPU utilisation over the last 5 minutes. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.3.8.1.8ColumncpuUtilisationStackAvgLast5Minutesread-onlycurrentAverage CPU utilisation over the past 5 minutes. Expressed as a percentage.
1.3.6.1.4.1.207.8.4.4.3.4NodesysTemperature
1.3.6.1.4.1.207.8.4.4.3.4.1NodegeneralTemperature
1.3.6.1.4.1.207.8.4.4.3.4.1.0NodegeneralTemperatureTrap
1.3.6.1.4.1.207.8.4.4.3.4.1.0.1NotificationgeneralTemperatureStatusTrapcurrentGenerated when the temperature status of the device changes.
1.3.6.1.4.1.207.8.4.4.3.4.1.1ScalargeneralTemperatureSupportedread-onlycurrentThe value supported indicates general temperature is displayed by the device. The value notSupported indicates the device displays specific temperature informa…
1.3.6.1.4.1.207.8.4.4.3.4.1.2ScalargeneralTemperatureActualTempread-onlycurrentThe current temperature of product's base board, in degrees Celsius. A device which doesn't support this group will return the value 0 for this variable.
1.3.6.1.4.1.207.8.4.4.3.4.1.3ScalargeneralTemperatureStatusread-onlycurrentThe status of temperature in this device. ok indicates the temperature is below the threshold temperature or the device is not capable of monitoring temperatur…
1.3.6.1.4.1.207.8.4.4.3.4.1.4ScalargeneralTemperatureThresholdread-writecurrentThe temperature threshold for the device. If the temperature of the device rises above this threshold generalTemeratureStatus will indicate a notOk status.
1.3.6.1.4.1.207.8.4.4.3.4.2NodesbTemperature
1.3.6.1.4.1.207.8.4.4.3.4.2.0NodesbTemperatureTrap
1.3.6.1.4.1.207.8.4.4.3.4.2.0.1NotificationsbTempFixedThresholdTrapcurrentTrap occurs when fixed threshold status changes. The actual temperature and the fixed threshold are also given.
1.3.6.1.4.1.207.8.4.4.3.4.2.0.2NotificationsbTempSettableThresholdTrapcurrentTrap occurs when settable threshold status changes. The actual temperature and the settable threshold are also given.
1.3.6.1.4.1.207.8.4.4.3.4.2.1TablesbTempTablenot-accessiblecurrentThe table of SwitchBlade sysTemperature. Each entry in the table represents temperature monitoring from one of the CPU cards which may be present in the Switch…
1.3.6.1.4.1.207.8.4.4.3.4.2.1.1RowsbTempEntrynot-accessiblecurrentA single entry of SwitchBlade sysTemperature
1.3.6.1.4.1.207.8.4.4.3.4.2.1.1.1ColumnsbTempIndexread-onlycurrentThe board for which this temperature entry holds. If the system consists only of a single CPU board, only one entry will appear in the table, whose index is ma…
1.3.6.1.4.1.207.8.4.4.3.4.2.1.1.2ColumnsbTempActualTemperatureread-onlycurrentThe actual SwitchBlade temperature. This temperature is measured within the SwitchBlade CPU, and is sampled at 1 second intervals.
1.3.6.1.4.1.207.8.4.4.3.4.2.1.1.3ColumnsbTempFixedThresholdStatusread-onlycurrentThe temperature status with regard to the fixed temperature threshold. The value of the fixed temperature threshold is set at 90 degrees C. This variable repre…
1.3.6.1.4.1.207.8.4.4.3.4.2.1.1.4ColumnsbTempSettableThresholdStatusread-onlycurrentThe temperature status with regard to the settable temperature threshold. The value of the settable temperature threshold is set by management intervention. Th…
1.3.6.1.4.1.207.8.4.4.3.4.2.1.1.5ColumnsbTempSettableThresholdread-writecurrentThe value of the settable temperature threshold. This can be set independently for each temperature entry. The value of this threshold is only valid when sbTem…
1.3.6.1.4.1.207.8.4.4.3.4.2.2ScalarsbTempFixedThresholdread-onlycurrentThe value of the fixed temperature threshold. This value is fixed for both CPU cards, and cannot be set.
1.3.6.1.4.1.207.8.4.4.3.4.3NodeacceleratorTemperature
1.3.6.1.4.1.207.8.4.4.3.4.3.0NodeacceleratorTemperatureTrap
1.3.6.1.4.1.207.8.4.4.3.4.3.0.1NotificationacceleratorTemperatureStatusTrapcurrentGenerated when the temperature status of the device changes.
1.3.6.1.4.1.207.8.4.4.3.4.3.1ScalaracceleratorTemperatureSupportedread-onlycurrentThe value supported indicates whether accelerator card temperature is displayed by the device. The value notSupported indicates the device does not display spe…
1.3.6.1.4.1.207.8.4.4.3.4.3.2ScalaracceleratorTemperatureActualTempread-onlycurrentThe current temperature of product's base board, in degrees Celsius. A device which doesn't support this group will return the value 0 for this variable.
1.3.6.1.4.1.207.8.4.4.3.4.3.3ScalaracceleratorTemperatureStatusread-onlycurrentThe status of temperature in this device. ok indicates the temperature is below the threshold temperature or the device is not capable of monitoring temperatur…
1.3.6.1.4.1.207.8.4.4.3.4.3.4ScalaracceleratorTemperatureThresholdread-onlycurrentThe temperature threshold for the device. If the temperature of the device rises above this threshold generalTemeratureStatus will indicate a notOk status.
1.3.6.1.4.1.207.8.4.4.3.5ScalaratContactDetailsread-onlycurrentThe contact details for Allied Telesis inc.
1.3.6.1.4.1.207.8.4.4.3.6NodebbrNvs
1.3.6.1.4.1.207.8.4.4.3.6.0NodebbrNvsTrap
1.3.6.1.4.1.207.8.4.4.3.6.0.1NotificationbbrNvsReinitialiseTrapcurrentGenerated at boot when the device detects that the BBR has been corrupted and reinitialised. This can happen if the device's BBR battery has run down, and the …
1.3.6.1.4.1.207.8.4.4.3.7Nodememory
1.3.6.1.4.1.207.8.4.4.3.7.1ScalarfreeMemoryread-onlycurrentPercentage of free memory still available on device
1.3.6.1.4.1.207.8.4.4.3.7.2ScalartotalBuffersread-onlycurrentTotal number of buffers available on device
1.3.6.1.4.1.207.8.4.4.3.7.11NotificationlowMemoryTrapcurrentA low memory trap is generated when a router's memory has gone below a certain level.
1.3.6.1.4.1.207.8.4.4.3.8ScalarrealTimeClockStatusread-onlycurrentShows the status of the real time clock
1.3.6.1.4.1.207.8.4.4.3.9ScalarhostIdread-writecurrentHost Identifier of this device
1.3.6.1.4.1.207.8.4.4.3.14NodeatPortInfo
1.3.6.1.4.1.207.8.4.4.3.14.1TableatPortInfoTransceiverTablenot-accessiblecurrentA table of information about the transceiver of a interface.
1.3.6.1.4.1.207.8.4.4.3.14.1.1RowatPortInfoTransceiverEntrynot-accessiblecurrentThe description, the transceiver type of a interface.
1.3.6.1.4.1.207.8.4.4.3.14.1.1.1ColumnatPortInfoTransceiverifIndexread-onlycurrentThe ifIndex for the interface represented by this entry of the interfaces table.
1.3.6.1.4.1.207.8.4.4.3.14.1.1.2ColumnatPortInfoTransceiverTyperead-onlycurrentThis object indicates the type of transceiver on a interface.
1.3.6.1.4.1.207.8.4.4.3.14.2ScalaratPortRenumberEventsread-onlycurrentThe number of times that port number values (represented by the dot1dBasePort object in BRIDGE-MIB), have been re-assigned due to stack member leave/join event…