MIB Viewer

ATEN-IPMI-MIB

221 objects
Top-level infrastructure of the ATEN CORP. enterprise MIB tree
Imported Objects
SNMPv2-SMIenterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDateAndTime
OIDNameAccessStatusDescription
1.3.6.1.4.1.21317IdentityatenTop-level infrastructure of the ATEN CORP. enterprise MIB tree
1.3.6.1.4.1.21317.1Nodeipmi
1.3.6.1.4.1.21317.1.2Scalarselread-writecurrentNumber of SELs
1.3.6.1.4.1.21317.1.3TablesensorTablenot-accessiblecurrentA list of sensors. The number of entries is given by the value of ifNumber.
1.3.6.1.4.1.21317.1.3.1RowsensorEntrynot-accessiblecurrentAn entry containing management information applicable to a particular sensor.
1.3.6.1.4.1.21317.1.3.1.1ColumnsensorNumberread-onlycurrentA unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface su…
1.3.6.1.4.1.21317.1.3.1.2ColumnsensorReadingread-onlycurrentA textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the i…
1.3.6.1.4.1.21317.1.3.1.3ColumnsensorPositiveHysteresisread-onlycurrentThe type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifTy…
1.3.6.1.4.1.21317.1.3.1.4ColumnsensorNegativeHysteresisread-onlycurrentThe size of the largest packet which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagram…
1.3.6.1.4.1.21317.1.3.1.5ColumnlncThresholdread-onlycurrentAn estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation ca…
1.3.6.1.4.1.21317.1.3.1.6ColumnlcThresholdread-onlycurrentThe interface's address at its protocol sub-layer. For example, for an 802.x interface, this object normally contains a MAC address. The interface's media-spec…
1.3.6.1.4.1.21317.1.3.1.7ColumnlnrThresholdread-onlycurrentThe desired state of the interface. The testing(3) state indicates that no operational packets can be passed. When a managed system initializes, all interfaces…
1.3.6.1.4.1.21317.1.3.1.8ColumnuncThresholdread-onlycurrentThe current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. If ifAdminStatus is down(2) then ifOp…
1.3.6.1.4.1.21317.1.3.1.9ColumnucThresholdread-onlycurrentThe value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re-initialization of…
1.3.6.1.4.1.21317.1.3.1.10ColumnunrThresholdread-onlycurrentThe total number of octets received on the interface, including framing characters. Discontinuities in the value of this counter can occur at re-initialization…
1.3.6.1.4.1.21317.1.3.1.11ColumneventAssertionEnableread-onlycurrentThe number of packets, delivered by this sub-layer to a higher (sub-)layer, which were not addressed to a multicast or broadcast address at this sub-layer. Dis…
1.3.6.1.4.1.21317.1.3.1.12ColumneventDeassertionEnableread-onlycurrentThe number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast or broadcast address at this sub-layer. Discont…
1.3.6.1.4.1.21317.1.3.1.13ColumnsensorIDStringread-onlycurrent16-byte length field for displaying each available sensors' ID string.
1.3.6.1.4.1.21317.1.4ScalarpowerStatusread-writecurrentGet and set the power status of system. Set case: 0 : power off 1 : power on 2 : power reset
1.3.6.1.4.1.21317.1.5Nodeboardinfo
1.3.6.1.4.1.21317.1.5.1ScalarbmcMajorVesionread-onlycurrentBMC Major Vesion
1.3.6.1.4.1.21317.1.5.2ScalarbmcMinorVesionread-onlycurrentBMC Minor Vesion
1.3.6.1.4.1.21317.1.5.3ScalarbmcBuildDateread-onlycurrentBMC FW Build Date
1.3.6.1.4.1.21317.1.5.4ScalarbiosVesionread-onlycurrentBIOS Vesion
1.3.6.1.4.1.21317.1.5.5ScalarbiosBuildDateread-onlycurrentBIOS Build Date
1.3.6.1.4.1.21317.1.5.6ScalarhostNameread-onlycurrentBMC Host Name
1.3.6.1.4.1.21317.1.5.7ScalarbmcBuildVesionread-onlycurrentBMC Build Vesion
1.3.6.1.4.1.21317.1.6Nodehardwareinfo
1.3.6.1.4.1.21317.1.6.1ScalarserialNumberread-onlycurrentMotherboard Serial Number
1.3.6.1.4.1.21317.1.6.2TablecpuTablenot-accessiblecurrentA list of CPUs. The number of entries is given by the number of CPUs.
1.3.6.1.4.1.21317.1.6.2.1RowcpuEntrynot-accessiblecurrentAn entry containing management information applicable to a particular CPU.
1.3.6.1.4.1.21317.1.6.2.1.1ColumncpuNumberread-onlycurrentA unique value, greater than zero, for each CPU. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.21317.1.6.2.1.2Columnprocessorread-onlycurrentProcessor name.
1.3.6.1.4.1.21317.1.6.2.1.3Columnspeedread-onlycurrentProcessor speed (MHz).
1.3.6.1.4.1.21317.1.6.2.1.4Columncoreread-onlycurrentThe number of processor cores.
1.3.6.1.4.1.21317.1.6.2.1.5ColumncoreActiveread-onlycurrentThe number of active processor cores.
1.3.6.1.4.1.21317.1.6.2.1.6Columnmanufacturerread-onlycurrentCPU Manufacturer
1.3.6.1.4.1.21317.1.6.3TabledimmTablenot-accessiblecurrentA list of DIMMs. The number of entries is given by the number of DIMMs.
1.3.6.1.4.1.21317.1.6.3.1RowdimmEntrynot-accessiblecurrentAn entry containing management information applicable to a particular DIMM.
1.3.6.1.4.1.21317.1.6.3.1.1ColumndimmNumberread-onlycurrentA unique value, greater than zero, for each DIMM. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.21317.1.6.3.1.2ColumndimmLocationread-onlycurrentThe location of this DIMM.
1.3.6.1.4.1.21317.1.6.3.1.3ColumndimmMaxCapSpeedread-onlycurrentThe max capable speed (MHz) of this DIMM.
1.3.6.1.4.1.21317.1.6.3.1.4ColumndimmOpSpeedread-onlycurrentThe current operation speed (MHz) of this DIMM.
1.3.6.1.4.1.21317.1.6.3.1.5ColumndimmSizeread-onlycurrentThe size (MBytes) of this DIMM.
1.3.6.1.4.1.21317.1.6.3.1.6ColumndimmSerialNoread-onlycurrentThe serial number of this DIMM.
1.3.6.1.4.1.21317.1.6.3.1.7ColumndimmPartNoread-onlycurrentThe serial number of this DIMM.
1.3.6.1.4.1.21317.1.6.3.1.8ColumndimmManufacturerread-onlycurrentThe manufacturer of this DIMM.
1.3.6.1.4.1.21317.1.7Nodestorage
1.3.6.1.4.1.21317.1.7.1TablecontrollerTablenot-accessiblecurrentA list of raid controllers. The number of entries is given by the number of controllers.
1.3.6.1.4.1.21317.1.7.1.1RowcontrollerEntrynot-accessiblecurrentAn entry containing management information applicable to a particular controller.
1.3.6.1.4.1.21317.1.7.1.1.1ColumncontrollerNumberread-onlycurrentA unique value, greater than zero, for each controller. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.21317.1.7.1.1.2ColumncontrollerProductNameread-onlycurrentProduct name of the controller.
1.3.6.1.4.1.21317.1.7.1.1.3Columnserialread-onlycurrentSerial number of the controller.
1.3.6.1.4.1.21317.1.7.1.1.4Columnpackageread-onlycurrentPackage version of the controller.
1.3.6.1.4.1.21317.1.7.1.1.5ColumnfwVersionread-onlycurrentFirmware version of the controller.
1.3.6.1.4.1.21317.1.7.1.1.6ColumnbiosVersionread-onlycurrentBIOS version of the controller.
1.3.6.1.4.1.21317.1.7.1.1.7ColumnbootBlockVersionread-onlycurrentBoot block version of the controller.
1.3.6.1.4.1.21317.1.7.1.1.8ColumnbatteryStatusread-onlycurrentBattery status of the controller. 0: Missing 1: Charging 2: Discharging 3: Optimal 4: Needs to be replaced
1.3.6.1.4.1.21317.1.7.1.1.9ColumnpcieLocationread-onlycurrentPCIE location of the controller. 0: ONBOARD 1: RISER WIO Right 2: RISER WIO Left 3: RISER Ultra IO
1.3.6.1.4.1.21317.1.7.1.1.10ColumnpcieSlotread-onlycurrentPCIE slot number of the controller.
1.3.6.1.4.1.21317.1.7.2TablephyHddTablenot-accessiblecurrentA list of HDDs. The number of entries is given by the number of HDDs.
1.3.6.1.4.1.21317.1.7.2.1RowhddEntrynot-accessiblecurrentAn entry containing management information applicable to a particular HDD.
1.3.6.1.4.1.21317.1.7.2.1.1ColumnhddNumberread-onlycurrentA unique value, greater than zero, for each HDD. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.21317.1.7.2.1.2ColumnhddControllerNumberread-onlycurrentThe controller that this HDD belongs to.
1.3.6.1.4.1.21317.1.7.2.1.3ColumnenclosureNumberread-onlycurrentThe enclosure that this HDD belongs to.
1.3.6.1.4.1.21317.1.7.2.1.4Columnstatusread-onlycurrentCurrent status of the HDD. 1: present 0: not present
1.3.6.1.4.1.21317.1.7.2.1.5Columntemperatureread-onlycurrentCurrent temperature of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.6Columncapacityread-onlycurrentCapacity(GB) of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.7Columnvendorread-onlycurrentThe vendor of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.8ColumnmodelNameread-onlycurrentModel name of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.9Columnrevisionread-onlycurrentRevision of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.10Columnsnread-onlycurrentThe serial number of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.11ColumnlinkSpeedread-onlycurrentThe link speed of the HDD. 0: not defined 1: 1.5Gb/s - SATA 150 2: 3.0Gb/s 3: 6.0Gb/s 4: 12.0Gb/s
1.3.6.1.4.1.21317.1.7.2.1.12ColumnfwStateread-onlycurrentThe firmware state of the HDD. 00: Unconfigured good drive 01: Unconfigured bad drive 02: Hot spare drive 16: Configured-good drive(data invalid) 17: Configure…
1.3.6.1.4.1.21317.1.7.2.1.13ColumnotherErrCountread-onlycurrentOther error count of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.14ColumnpredictedFailCountread-onlycurrentPredicted fail count of the HDD.
1.3.6.1.4.1.21317.1.7.2.1.15ColumnmediaErrCountread-onlycurrentMedia error Count of the HDD.
1.3.6.1.4.1.21317.1.7.3TablelogHddTablenot-accessiblecurrentA list of volumes. The number of entries is given by the number of volumes.
1.3.6.1.4.1.21317.1.7.3.1RowvolumeEntrynot-accessiblecurrentAn entry containing management information applicable to a particular volume.
1.3.6.1.4.1.21317.1.7.3.1.1ColumnvolNumberread-onlycurrentA unique value, greater than zero, for each volume. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.21317.1.7.3.1.2ColumnvolControllerNumberread-onlycurrentThe controller that this HDD belongs to.
1.3.6.1.4.1.21317.1.7.3.1.3ColumnvolStatusread-onlycurrentCurrent status of the volume. 1: present 0: not present
1.3.6.1.4.1.21317.1.7.3.1.4ColumnvolCapacityread-onlycurrentCapacity(GB) of the volume.
1.3.6.1.4.1.21317.1.7.3.1.5ColumnpriRaidLevelread-onlycurrentPrimary raid level of the volume.
1.3.6.1.4.1.21317.1.7.3.1.6ColumnraidLevelQualifierread-onlycurrentRaid level qaulifier of the volume.
1.3.6.1.4.1.21317.1.7.3.1.7ColumnsecRaidLevelread-onlycurrentSecondary raid level of the volume.
1.3.6.1.4.1.21317.1.7.3.1.8ColumnldStripSizeread-onlycurrentLD strip size of the volume. (per DDF: 4=8K, 5=16K, 7=64K, 11=1MB, etc.)
1.3.6.1.4.1.21317.1.7.3.1.9ColumnnumDevicesread-onlycurrentnumber of drives per span.
1.3.6.1.4.1.21317.1.7.3.1.10ColumnspanDepthread-onlycurrentSpan depth of the volume.
1.3.6.1.4.1.21317.1.7.3.1.11Columnstateread-onlycurrentState of the volume. 0: offline 1: partially degraded 2: degraded 3: optimal
1.3.6.1.4.1.21317.1.7.3.1.12ColumnvolNameread-onlycurrentThe name of the volume.
1.3.6.1.4.1.21317.1.8ScalarcoldResetBMCread-writecurrentCold reset the BMC.
1.3.6.1.4.1.21317.1.9TableuserTablenot-accessiblecurrentA list of all users.
1.3.6.1.4.1.21317.1.9.1RowuserInfonot-accessiblecurrentAn entry containing management information applicable to a particular user.
1.3.6.1.4.1.21317.1.9.1.1Columnidread-onlycurrentA unique value for user ID, greater than zero.
1.3.6.1.4.1.21317.1.9.1.2Columnusernameread-writecurrentUser name.
1.3.6.1.4.1.21317.1.9.1.3Columnpasswordread-writecurrentPassword.
1.3.6.1.4.1.21317.1.9.1.4Columnprivilegeread-writecurrentUser privilege.
1.3.6.1.4.1.21317.1.10Scalaruidread-writecurrentGet and set the UID status. Get case: 0 : off 1 : on Set case: 0 : off 1 : on
1.3.6.1.4.1.21317.1.11TablealertTablenot-accessiblecurrentA list of all alerts.
1.3.6.1.4.1.21317.1.11.1RowalertInfonot-accessiblecurrentAn entry containing management information applicable to a particular alert.
1.3.6.1.4.1.21317.1.11.1.1ColumnalertNoread-onlycurrentA unique value for alert ID, greater than zero.
1.3.6.1.4.1.21317.1.11.1.2ColumnalertLevelread-onlycurrentAlert Level.
1.3.6.1.4.1.21317.1.11.1.3ColumndestinationAddressread-onlycurrentAlert Level.
1.3.6.1.4.1.21317.1.14Nodepowerinfo
1.3.6.1.4.1.21317.1.14.1ScalarpsuNumberread-onlycurrentNumber of PSUs
1.3.6.1.4.1.21317.1.14.2TablepsuTablenot-accessiblecurrentA list of PSUs. The number of entries is given by the number of PSUs.
1.3.6.1.4.1.21317.1.14.2.1RowpsuEntrynot-accessiblecurrentAn entry containing a particular PSU information.
1.3.6.1.4.1.21317.1.14.2.1.1ColumnpsuIndexread-onlycurrentA unique value, start from one, for each PSU. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.21317.1.14.2.1.2ColumnpsuStatusread-onlycurrentPSU Status.
1.3.6.1.4.1.21317.1.14.2.1.3ColumninputVoltageread-onlycurrentPSU Input Voltage.
1.3.6.1.4.1.21317.1.14.2.1.4ColumninputCurrentread-onlycurrentPSU Input Current.
1.3.6.1.4.1.21317.1.14.2.1.5ColumninputPowerread-onlycurrentPSU Input Power.
1.3.6.1.4.1.21317.1.14.2.1.6ColumnoutputVoltageread-onlycurrentPSU Output Voltage.
1.3.6.1.4.1.21317.1.14.2.1.7ColumnoutputCurrentread-onlycurrentPSU Output Current.
1.3.6.1.4.1.21317.1.14.2.1.8ColumnoutputPowerread-onlycurrentPSU Output Power.
1.3.6.1.4.1.21317.1.14.2.1.9Columntemperature1read-onlycurrentPSU Temperature1.
1.3.6.1.4.1.21317.1.14.2.1.10Columntemperature2read-onlycurrentPSU Temperature2.
1.3.6.1.4.1.21317.1.14.2.1.11ColumnfanRPM1read-onlycurrentPSU Fan RPM1.
1.3.6.1.4.1.21317.1.14.2.1.12ColumnfanRPM2read-onlycurrentPSU Fan RPM2.
1.3.6.1.4.1.21317.1.14.2.1.13ColumnpsuSerialNumberread-onlycurrentPSU Serial Number.
1.3.6.1.4.1.21317.1.15ScalarfanModeread-onlycurrent
1.3.6.1.4.1.21317.1.16Nodefruinfo
1.3.6.1.4.1.21317.1.16.1Nodechassis
1.3.6.1.4.1.21317.1.16.1.1ScalarchassisTyperead-onlycurrentFRU Chassis Type.
1.3.6.1.4.1.21317.1.16.1.2ScalarchassisPartNumberread-onlycurrentFRU Chassis Part Number
1.3.6.1.4.1.21317.1.16.1.3ScalarchassisSerialNumberread-onlycurrentFRU Chassis Serial Number
1.3.6.1.4.1.21317.1.16.2Nodeboard
1.3.6.1.4.1.21317.1.16.2.1ScalarboardLanguageread-onlycurrentFRU Board Language
1.3.6.1.4.1.21317.1.16.2.2ScalarboardManufacturerread-onlycurrentFRU Board Manufacturer
1.3.6.1.4.1.21317.1.16.2.3ScalarboardProductNameread-onlycurrentFRU Board Product Name
1.3.6.1.4.1.21317.1.16.2.4ScalarboardSerialNumberread-onlycurrentFRU Board Serial Number
1.3.6.1.4.1.21317.1.16.2.5ScalarboardPartNumberread-onlycurrentFRU Board part Number
1.3.6.1.4.1.21317.1.16.3Nodeproduct
1.3.6.1.4.1.21317.1.16.3.1ScalarproductLanguageread-onlycurrentFRU Product Language
1.3.6.1.4.1.21317.1.16.3.2ScalarproductManufacturerread-onlycurrentFRU Product Manufacturer
1.3.6.1.4.1.21317.1.16.3.3ScalarproductNameread-onlycurrentFRU Product Name
1.3.6.1.4.1.21317.1.16.3.4ScalarproductPartNumberread-onlycurrentFRU Product Part Number
1.3.6.1.4.1.21317.1.16.3.5ScalarproductVersionread-onlycurrentFRU Product Version
1.3.6.1.4.1.21317.1.16.3.6ScalarproductSerialNumberread-onlycurrentFRU Product Serial Number
1.3.6.1.4.1.21317.1.16.3.7ScalarproductAssetTagread-writecurrentFRU Product Asset Tag
1.3.6.1.4.1.21317.1.17Nodentpinfo
1.3.6.1.4.1.21317.1.17.1ScalartimeZoneread-onlycurrentGet and set time zone. Get/Set case: -1200 -1100 -1000 -0930 -0900 -0800 -0700 -0600 -0500 -0430 -0400 -0330 -0300 -0230 -0200 -0100 +0000 +0100 +0200 +0300 +0…
1.3.6.1.4.1.21317.1.17.2ScalarntpEnableread-onlycurrentGet and set NTP status. Get case: 0 : off 1 : on Set case: 0 : off 1 : on
1.3.6.1.4.1.21317.1.17.3ScalarprimaryNTPServerread-onlycurrentGet and set primary NTP server
1.3.6.1.4.1.21317.1.17.4ScalarsecondaryNTPServerread-onlycurrentGet and set secondary NTP server
1.3.6.1.4.1.21317.1.17.5Scalardstread-onlycurrentGet and set daylight saving time status Get case: 0 : off 1 : on Set case: 0 : off 1 : on
1.3.6.1.4.1.21317.1.18TableselTablenot-accessiblecurrentThis table displays a record of critical system events from the monitored system.
1.3.6.1.4.1.21317.1.18.1RowselEntrynot-accessiblecurrentAn entry event logs indicate the time when a critical condition occurred and the time it was resolved
1.3.6.1.4.1.21317.1.18.1.1ColumnselEidread-onlycurrentsystem event log EID
1.3.6.1.4.1.21317.1.18.1.2ColumnselTimeStampread-onlycurrentSystem event log trigger time
1.3.6.1.4.1.21317.1.18.1.3ColumnselSensorNameread-onlycurrentSystem evnet log sensor name
1.3.6.1.4.1.21317.1.18.1.4ColumnselSensorTyperead-onlycurrentSystem evnet log sensor type
1.3.6.1.4.1.21317.1.18.1.5ColumnselDescriptionread-onlycurrentSystem evnet log description
1.3.6.1.4.1.21317.1.18.1.6ColumnselRawDataread-onlycurrentSystem evnet log raw data
1.3.6.1.4.1.21317.1.19Nodenvme
1.3.6.1.4.1.21317.1.19.1TablenvmeCtrlTblnot-accessiblecurrentA list of NVMe controllers. The number of entries is given by the number of controllers.
1.3.6.1.4.1.21317.1.19.1.1RownvmeCtrlEntrynot-accessiblecurrentAn entry containing a particular NVMe controller information.
1.3.6.1.4.1.21317.1.19.1.1.1ColumnnvmeCtrlPresentread-onlycurrentNVMe controllor present or not.
1.3.6.1.4.1.21317.1.19.1.1.2ColumnmaxTempread-onlycurrentThe maximum temperature from all existed NVMe drives.
1.3.6.1.4.1.21317.1.19.1.1.3ColumnmaxSlotNumread-onlycurrentMaximum slot number at each group.
1.3.6.1.4.1.21317.1.19.1.1.4Columnonboardread-onlycurrentNVMe controller type.
1.3.6.1.4.1.21317.1.19.1.1.5ColumndriverIndexread-onlycurrentNVMe BPN driver index.
1.3.6.1.4.1.21317.1.19.1.1.6ColumncpldVerread-onlycurrentCPLD FW version of this NVMe controller.
1.3.6.1.4.1.21317.1.19.2TablenvmeDriveTblnot-accessiblecurrentA list of NVMe drives. The number of entries is given by the number of drives.
1.3.6.1.4.1.21317.1.19.2.1RownvmeDriveEntrynot-accessiblecurrentAn entry containing a particular NVMe drive information.
1.3.6.1.4.1.21317.1.19.2.1.1ColumnslotIdread-onlycurrentNVMe Slot ID at one group.
1.3.6.1.4.1.21317.1.19.2.1.2ColumngroupIdread-onlycurrentGroup ID at this slot.
1.3.6.1.4.1.21317.1.19.2.1.3ColumnnvmeDrivePresentread-onlycurrentNVMe drive presence at this slot.
1.3.6.1.4.1.21317.1.19.2.1.4Columnlocateread-onlycurrentNVMe drive locate/dislocate status at this slot.
1.3.6.1.4.1.21317.1.19.2.1.5Columnsave2Removeread-onlycurrentNVMe drive save2Remove status at this slot.
1.3.6.1.4.1.21317.1.19.2.1.6ColumnvmdModeread-onlycurrentNVMe drive vmdMode status at this slot.
1.3.6.1.4.1.21317.1.19.2.1.7Columntempread-onlycurrentNVMe drive temperature at this slot.
1.3.6.1.4.1.21317.1.19.2.1.8ColumnclassCoderead-onlycurrentNVMe drive class code at this slot.
1.3.6.1.4.1.21317.1.19.2.1.9ColumnvendorIDread-onlycurrentNVMe drive class code at this slot.
1.3.6.1.4.1.21317.1.19.2.1.10ColumnserialNumread-onlycurrentNVMe drive serial number at this slot.
1.3.6.1.4.1.21317.1.19.2.1.11ColumnmodelNumread-onlycurrentNVMe drive model number at this slot.
1.3.6.1.4.1.21317.1.19.2.1.12Columnport0MaxLinkSpdread-onlycurrentNVMe drive port0 max link speed at this slot.
1.3.6.1.4.1.21317.1.19.2.1.13Columnport0MaxLinkWidthread-onlycurrentNVMe drive port0 max link width at this slot.
1.3.6.1.4.1.21317.1.19.2.1.14Columnport1MaxLinkSpdread-onlycurrentNVMe drive port1 max link speed at this slot.
1.3.6.1.4.1.21317.1.19.2.1.15Columnport1MaxLinkWidthread-onlycurrentNVMe drive port1 max link width at this slot.
1.3.6.1.4.1.21317.1.19.2.1.16ColumninitPowerRequirementread-onlycurrentInitial power requirment (Watts).
1.3.6.1.4.1.21317.1.19.2.1.17ColumnmaxPowerRequirementread-onlycurrentMaximum power requirment (Watts).
1.3.6.1.4.1.21317.1.20TablenicTablenot-accessiblecurrentA list of NICs. The number of entries is given by the number of NICs.
1.3.6.1.4.1.21317.1.20.1RownicEntrynot-accessiblecurrentAn entry containing management information applicable to a particular NIC.
1.3.6.1.4.1.21317.1.20.1.1ColumnnicNumberread-onlycurrentA unique value, greater than zero, for each NIC. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.21317.1.20.1.2ColumnnicNameread-onlycurrentName of the NIC.
1.3.6.1.4.1.21317.1.20.1.3ColumnnicMacread-onlycurrentMAC of the NIC.
1.3.6.1.4.1.21317.1.20.1.4ColumnnicIpv4Addrread-onlycurrentIPv4 address of the NIC.
1.3.6.1.4.1.21317.1.20.1.5ColumnnicIpv6Addrread-onlycurrentIPv6 address of the NIC.
1.3.6.1.4.1.21317.1.20.1.6ColumnnicGatewayread-onlycurrentGateway of the NIC.
1.3.6.1.4.1.21317.1.20.1.7ColumnnicNetmaskread-onlycurrentNetmask of the NIC.
1.3.6.1.4.1.21317.1.20.1.8ColumnnicFqdnread-onlycurrentFQDN of the NIC.
1.3.6.1.4.1.21317.1.20.1.9ColumnnicDnsread-onlycurrentDNS of the NIC.
1.3.6.1.4.1.21317.1.20.1.10ColumnnicSpeedread-onlycurrentSpeed of the NIC. (Unit: Mbps)
1.3.6.1.4.1.21317.1.20.1.11ColumnnicDescriptread-onlycurrentDescription of the NIC.
1.3.6.1.4.1.21317.1.20.1.12ColumnnicStatusread-onlycurrentStatus of the NIC.
1.3.6.1.4.1.21317.1.21Nodenetwork
1.3.6.1.4.1.21317.1.21.1Scalaripv4DNSServerread-onlycurrentIPv4 dns server.
1.3.6.1.4.1.21317.1.21.2Scalaripv4Gatewayread-onlycurrentIPv4 gateway
1.3.6.1.4.1.21317.1.21.3Scalaripv6DNSServerread-onlycurrentIPv6 dns server.
1.3.6.1.4.1.21317.1.21.4Scalaripv6DUIDread-onlycurrentIPv6 DUID
1.3.6.1.4.1.21317.1.21.5Scalardhcpv6Stateread-onlycurrentDHCPv6 State
1.3.6.1.4.1.21317.1.21.6Scalarhostnameread-onlycurrentBMC hostname
1.3.6.1.4.1.21317.1.21.7ScalardhcpEnabledread-onlycurrentDHCP enabled
1.3.6.1.4.1.21317.1.21.8ScalarvlanIDEnabledread-onlycurrentVLan enabled
1.3.6.1.4.1.21317.1.21.9ScalarvlanIDread-onlycurrentVlan ID
1.3.6.1.4.1.21317.1.21.10ScalarlanInterfaceread-onlycurrentthe current Lan interface
1.3.6.1.4.1.21317.1.21.11ScalarrmcpPortread-onlycurrentIPMI port number
1.3.6.1.4.1.21317.1.21.12ScalaractiveLanInterfaceread-onlycurrentwhich Lan interface is active.
1.3.6.1.4.1.21317.1.21.13ScalardedicatedLanDuplexread-onlycurrentDuplex Mode of the dedicated Lan
1.3.6.1.4.1.21317.1.21.14ScalarsharedLanDuplexread-onlycurrentDuplex Mode of the share Lan
1.3.6.1.4.1.21317.1.22Nodesmtp
1.3.6.1.4.1.21317.1.22.1ScalarsmtpEnabledread-onlycurrentenable Email server
1.3.6.1.4.1.21317.1.22.2ScalarsmtpServerread-onlycurrentEmail server
1.3.6.1.4.1.21317.1.22.3ScalarsmtpPortread-onlycurrentthe port number of the email server
1.3.6.1.4.1.21317.1.22.4ScalarsmtpUsernameread-onlycurrentthe username for email server's authentication
1.3.6.1.4.1.21317.1.22.5ScalarsmtpSenderEmailread-onlycurrentthe sender's email address
1.3.6.1.4.1.21317.1.23ScalarmouseModeread-onlycurrentthe port number of the email server
1.3.6.1.4.1.21317.1.24ScalarsysBootOrderread-writecurrentOne time change system boot order.
1.3.6.1.4.1.21317.1.30NotificationguidcurrentGUID.