ATEN-IPMI-MIB
221 objects
Top-level infrastructure of the ATEN CORP. enterprise MIB tree
Imported Objects
| SNMPv2-SMI | enterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DateAndTime |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21317 | Identityaten | Top-level infrastructure of the ATEN CORP. enterprise MIB tree | ||
| 1.3.6.1.4.1.21317.1 | Nodeipmi | |||
| 1.3.6.1.4.1.21317.1.2 | Scalarsel | read-write | current | Number of SELs |
| 1.3.6.1.4.1.21317.1.3 | TablesensorTable | not-accessible | current | A list of sensors. The number of entries is given by the value of ifNumber. |
| 1.3.6.1.4.1.21317.1.3.1 | RowsensorEntry | not-accessible | current | An entry containing management information applicable to a particular sensor. |
| 1.3.6.1.4.1.21317.1.3.1.1 | ColumnsensorNumber | read-only | current | A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface su… |
| 1.3.6.1.4.1.21317.1.3.1.2 | ColumnsensorReading | read-only | current | A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the i… |
| 1.3.6.1.4.1.21317.1.3.1.3 | ColumnsensorPositiveHysteresis | read-only | current | The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifTy… |
| 1.3.6.1.4.1.21317.1.3.1.4 | ColumnsensorNegativeHysteresis | read-only | current | The size of the largest packet which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagram… |
| 1.3.6.1.4.1.21317.1.3.1.5 | ColumnlncThreshold | read-only | current | An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation ca… |
| 1.3.6.1.4.1.21317.1.3.1.6 | ColumnlcThreshold | read-only | current | The interface's address at its protocol sub-layer. For example, for an 802.x interface, this object normally contains a MAC address. The interface's media-spec… |
| 1.3.6.1.4.1.21317.1.3.1.7 | ColumnlnrThreshold | read-only | current | The desired state of the interface. The testing(3) state indicates that no operational packets can be passed. When a managed system initializes, all interfaces… |
| 1.3.6.1.4.1.21317.1.3.1.8 | ColumnuncThreshold | read-only | current | The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. If ifAdminStatus is down(2) then ifOp… |
| 1.3.6.1.4.1.21317.1.3.1.9 | ColumnucThreshold | read-only | current | The value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re-initialization of… |
| 1.3.6.1.4.1.21317.1.3.1.10 | ColumnunrThreshold | read-only | current | The total number of octets received on the interface, including framing characters. Discontinuities in the value of this counter can occur at re-initialization… |
| 1.3.6.1.4.1.21317.1.3.1.11 | ColumneventAssertionEnable | read-only | current | The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were not addressed to a multicast or broadcast address at this sub-layer. Dis… |
| 1.3.6.1.4.1.21317.1.3.1.12 | ColumneventDeassertionEnable | read-only | current | The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast or broadcast address at this sub-layer. Discont… |
| 1.3.6.1.4.1.21317.1.3.1.13 | ColumnsensorIDString | read-only | current | 16-byte length field for displaying each available sensors' ID string. |
| 1.3.6.1.4.1.21317.1.4 | ScalarpowerStatus | read-write | current | Get and set the power status of system. Set case: 0 : power off 1 : power on 2 : power reset |
| 1.3.6.1.4.1.21317.1.5 | Nodeboardinfo | |||
| 1.3.6.1.4.1.21317.1.5.1 | ScalarbmcMajorVesion | read-only | current | BMC Major Vesion |
| 1.3.6.1.4.1.21317.1.5.2 | ScalarbmcMinorVesion | read-only | current | BMC Minor Vesion |
| 1.3.6.1.4.1.21317.1.5.3 | ScalarbmcBuildDate | read-only | current | BMC FW Build Date |
| 1.3.6.1.4.1.21317.1.5.4 | ScalarbiosVesion | read-only | current | BIOS Vesion |
| 1.3.6.1.4.1.21317.1.5.5 | ScalarbiosBuildDate | read-only | current | BIOS Build Date |
| 1.3.6.1.4.1.21317.1.5.6 | ScalarhostName | read-only | current | BMC Host Name |
| 1.3.6.1.4.1.21317.1.5.7 | ScalarbmcBuildVesion | read-only | current | BMC Build Vesion |
| 1.3.6.1.4.1.21317.1.6 | Nodehardwareinfo | |||
| 1.3.6.1.4.1.21317.1.6.1 | ScalarserialNumber | read-only | current | Motherboard Serial Number |
| 1.3.6.1.4.1.21317.1.6.2 | TablecpuTable | not-accessible | current | A list of CPUs. The number of entries is given by the number of CPUs. |
| 1.3.6.1.4.1.21317.1.6.2.1 | RowcpuEntry | not-accessible | current | An entry containing management information applicable to a particular CPU. |
| 1.3.6.1.4.1.21317.1.6.2.1.1 | ColumncpuNumber | read-only | current | A unique value, greater than zero, for each CPU. It is recommended that values are assigned contiguously starting from 1. |
| 1.3.6.1.4.1.21317.1.6.2.1.2 | Columnprocessor | read-only | current | Processor name. |
| 1.3.6.1.4.1.21317.1.6.2.1.3 | Columnspeed | read-only | current | Processor speed (MHz). |
| 1.3.6.1.4.1.21317.1.6.2.1.4 | Columncore | read-only | current | The number of processor cores. |
| 1.3.6.1.4.1.21317.1.6.2.1.5 | ColumncoreActive | read-only | current | The number of active processor cores. |
| 1.3.6.1.4.1.21317.1.6.2.1.6 | Columnmanufacturer | read-only | current | CPU Manufacturer |
| 1.3.6.1.4.1.21317.1.6.3 | TabledimmTable | not-accessible | current | A list of DIMMs. The number of entries is given by the number of DIMMs. |
| 1.3.6.1.4.1.21317.1.6.3.1 | RowdimmEntry | not-accessible | current | An entry containing management information applicable to a particular DIMM. |
| 1.3.6.1.4.1.21317.1.6.3.1.1 | ColumndimmNumber | read-only | current | A unique value, greater than zero, for each DIMM. It is recommended that values are assigned contiguously starting from 1. |
| 1.3.6.1.4.1.21317.1.6.3.1.2 | ColumndimmLocation | read-only | current | The location of this DIMM. |
| 1.3.6.1.4.1.21317.1.6.3.1.3 | ColumndimmMaxCapSpeed | read-only | current | The max capable speed (MHz) of this DIMM. |
| 1.3.6.1.4.1.21317.1.6.3.1.4 | ColumndimmOpSpeed | read-only | current | The current operation speed (MHz) of this DIMM. |
| 1.3.6.1.4.1.21317.1.6.3.1.5 | ColumndimmSize | read-only | current | The size (MBytes) of this DIMM. |
| 1.3.6.1.4.1.21317.1.6.3.1.6 | ColumndimmSerialNo | read-only | current | The serial number of this DIMM. |
| 1.3.6.1.4.1.21317.1.6.3.1.7 | ColumndimmPartNo | read-only | current | The serial number of this DIMM. |
| 1.3.6.1.4.1.21317.1.6.3.1.8 | ColumndimmManufacturer | read-only | current | The manufacturer of this DIMM. |
| 1.3.6.1.4.1.21317.1.7 | Nodestorage | |||
| 1.3.6.1.4.1.21317.1.7.1 | TablecontrollerTable | not-accessible | current | A list of raid controllers. The number of entries is given by the number of controllers. |
| 1.3.6.1.4.1.21317.1.7.1.1 | RowcontrollerEntry | not-accessible | current | An entry containing management information applicable to a particular controller. |
| 1.3.6.1.4.1.21317.1.7.1.1.1 | ColumncontrollerNumber | read-only | current | A unique value, greater than zero, for each controller. It is recommended that values are assigned contiguously starting from 1. |
| 1.3.6.1.4.1.21317.1.7.1.1.2 | ColumncontrollerProductName | read-only | current | Product name of the controller. |
| 1.3.6.1.4.1.21317.1.7.1.1.3 | Columnserial | read-only | current | Serial number of the controller. |
| 1.3.6.1.4.1.21317.1.7.1.1.4 | Columnpackage | read-only | current | Package version of the controller. |
| 1.3.6.1.4.1.21317.1.7.1.1.5 | ColumnfwVersion | read-only | current | Firmware version of the controller. |
| 1.3.6.1.4.1.21317.1.7.1.1.6 | ColumnbiosVersion | read-only | current | BIOS version of the controller. |
| 1.3.6.1.4.1.21317.1.7.1.1.7 | ColumnbootBlockVersion | read-only | current | Boot block version of the controller. |
| 1.3.6.1.4.1.21317.1.7.1.1.8 | ColumnbatteryStatus | read-only | current | Battery status of the controller. 0: Missing 1: Charging 2: Discharging 3: Optimal 4: Needs to be replaced |
| 1.3.6.1.4.1.21317.1.7.1.1.9 | ColumnpcieLocation | read-only | current | PCIE location of the controller. 0: ONBOARD 1: RISER WIO Right 2: RISER WIO Left 3: RISER Ultra IO |
| 1.3.6.1.4.1.21317.1.7.1.1.10 | ColumnpcieSlot | read-only | current | PCIE slot number of the controller. |
| 1.3.6.1.4.1.21317.1.7.2 | TablephyHddTable | not-accessible | current | A list of HDDs. The number of entries is given by the number of HDDs. |
| 1.3.6.1.4.1.21317.1.7.2.1 | RowhddEntry | not-accessible | current | An entry containing management information applicable to a particular HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.1 | ColumnhddNumber | read-only | current | A unique value, greater than zero, for each HDD. It is recommended that values are assigned contiguously starting from 1. |
| 1.3.6.1.4.1.21317.1.7.2.1.2 | ColumnhddControllerNumber | read-only | current | The controller that this HDD belongs to. |
| 1.3.6.1.4.1.21317.1.7.2.1.3 | ColumnenclosureNumber | read-only | current | The enclosure that this HDD belongs to. |
| 1.3.6.1.4.1.21317.1.7.2.1.4 | Columnstatus | read-only | current | Current status of the HDD. 1: present 0: not present |
| 1.3.6.1.4.1.21317.1.7.2.1.5 | Columntemperature | read-only | current | Current temperature of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.6 | Columncapacity | read-only | current | Capacity(GB) of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.7 | Columnvendor | read-only | current | The vendor of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.8 | ColumnmodelName | read-only | current | Model name of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.9 | Columnrevision | read-only | current | Revision of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.10 | Columnsn | read-only | current | The serial number of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.11 | ColumnlinkSpeed | read-only | current | The link speed of the HDD. 0: not defined 1: 1.5Gb/s - SATA 150 2: 3.0Gb/s 3: 6.0Gb/s 4: 12.0Gb/s |
| 1.3.6.1.4.1.21317.1.7.2.1.12 | ColumnfwState | read-only | current | The firmware state of the HDD. 00: Unconfigured good drive 01: Unconfigured bad drive 02: Hot spare drive 16: Configured-good drive(data invalid) 17: Configure… |
| 1.3.6.1.4.1.21317.1.7.2.1.13 | ColumnotherErrCount | read-only | current | Other error count of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.14 | ColumnpredictedFailCount | read-only | current | Predicted fail count of the HDD. |
| 1.3.6.1.4.1.21317.1.7.2.1.15 | ColumnmediaErrCount | read-only | current | Media error Count of the HDD. |
| 1.3.6.1.4.1.21317.1.7.3 | TablelogHddTable | not-accessible | current | A list of volumes. The number of entries is given by the number of volumes. |
| 1.3.6.1.4.1.21317.1.7.3.1 | RowvolumeEntry | not-accessible | current | An entry containing management information applicable to a particular volume. |
| 1.3.6.1.4.1.21317.1.7.3.1.1 | ColumnvolNumber | read-only | current | A unique value, greater than zero, for each volume. It is recommended that values are assigned contiguously starting from 1. |
| 1.3.6.1.4.1.21317.1.7.3.1.2 | ColumnvolControllerNumber | read-only | current | The controller that this HDD belongs to. |
| 1.3.6.1.4.1.21317.1.7.3.1.3 | ColumnvolStatus | read-only | current | Current status of the volume. 1: present 0: not present |
| 1.3.6.1.4.1.21317.1.7.3.1.4 | ColumnvolCapacity | read-only | current | Capacity(GB) of the volume. |
| 1.3.6.1.4.1.21317.1.7.3.1.5 | ColumnpriRaidLevel | read-only | current | Primary raid level of the volume. |
| 1.3.6.1.4.1.21317.1.7.3.1.6 | ColumnraidLevelQualifier | read-only | current | Raid level qaulifier of the volume. |
| 1.3.6.1.4.1.21317.1.7.3.1.7 | ColumnsecRaidLevel | read-only | current | Secondary raid level of the volume. |
| 1.3.6.1.4.1.21317.1.7.3.1.8 | ColumnldStripSize | read-only | current | LD strip size of the volume. (per DDF: 4=8K, 5=16K, 7=64K, 11=1MB, etc.) |
| 1.3.6.1.4.1.21317.1.7.3.1.9 | ColumnnumDevices | read-only | current | number of drives per span. |
| 1.3.6.1.4.1.21317.1.7.3.1.10 | ColumnspanDepth | read-only | current | Span depth of the volume. |
| 1.3.6.1.4.1.21317.1.7.3.1.11 | Columnstate | read-only | current | State of the volume. 0: offline 1: partially degraded 2: degraded 3: optimal |
| 1.3.6.1.4.1.21317.1.7.3.1.12 | ColumnvolName | read-only | current | The name of the volume. |
| 1.3.6.1.4.1.21317.1.8 | ScalarcoldResetBMC | read-write | current | Cold reset the BMC. |
| 1.3.6.1.4.1.21317.1.9 | TableuserTable | not-accessible | current | A list of all users. |
| 1.3.6.1.4.1.21317.1.9.1 | RowuserInfo | not-accessible | current | An entry containing management information applicable to a particular user. |
| 1.3.6.1.4.1.21317.1.9.1.1 | Columnid | read-only | current | A unique value for user ID, greater than zero. |
| 1.3.6.1.4.1.21317.1.9.1.2 | Columnusername | read-write | current | User name. |
| 1.3.6.1.4.1.21317.1.9.1.3 | Columnpassword | read-write | current | Password. |
| 1.3.6.1.4.1.21317.1.9.1.4 | Columnprivilege | read-write | current | User privilege. |
| 1.3.6.1.4.1.21317.1.10 | Scalaruid | read-write | current | Get and set the UID status. Get case: 0 : off 1 : on Set case: 0 : off 1 : on |
| 1.3.6.1.4.1.21317.1.11 | TablealertTable | not-accessible | current | A list of all alerts. |
| 1.3.6.1.4.1.21317.1.11.1 | RowalertInfo | not-accessible | current | An entry containing management information applicable to a particular alert. |
| 1.3.6.1.4.1.21317.1.11.1.1 | ColumnalertNo | read-only | current | A unique value for alert ID, greater than zero. |
| 1.3.6.1.4.1.21317.1.11.1.2 | ColumnalertLevel | read-only | current | Alert Level. |
| 1.3.6.1.4.1.21317.1.11.1.3 | ColumndestinationAddress | read-only | current | Alert Level. |
| 1.3.6.1.4.1.21317.1.14 | Nodepowerinfo | |||
| 1.3.6.1.4.1.21317.1.14.1 | ScalarpsuNumber | read-only | current | Number of PSUs |
| 1.3.6.1.4.1.21317.1.14.2 | TablepsuTable | not-accessible | current | A list of PSUs. The number of entries is given by the number of PSUs. |
| 1.3.6.1.4.1.21317.1.14.2.1 | RowpsuEntry | not-accessible | current | An entry containing a particular PSU information. |
| 1.3.6.1.4.1.21317.1.14.2.1.1 | ColumnpsuIndex | read-only | current | A unique value, start from one, for each PSU. It is recommended that values are assigned contiguously starting from 1. |
| 1.3.6.1.4.1.21317.1.14.2.1.2 | ColumnpsuStatus | read-only | current | PSU Status. |
| 1.3.6.1.4.1.21317.1.14.2.1.3 | ColumninputVoltage | read-only | current | PSU Input Voltage. |
| 1.3.6.1.4.1.21317.1.14.2.1.4 | ColumninputCurrent | read-only | current | PSU Input Current. |
| 1.3.6.1.4.1.21317.1.14.2.1.5 | ColumninputPower | read-only | current | PSU Input Power. |
| 1.3.6.1.4.1.21317.1.14.2.1.6 | ColumnoutputVoltage | read-only | current | PSU Output Voltage. |
| 1.3.6.1.4.1.21317.1.14.2.1.7 | ColumnoutputCurrent | read-only | current | PSU Output Current. |
| 1.3.6.1.4.1.21317.1.14.2.1.8 | ColumnoutputPower | read-only | current | PSU Output Power. |
| 1.3.6.1.4.1.21317.1.14.2.1.9 | Columntemperature1 | read-only | current | PSU Temperature1. |
| 1.3.6.1.4.1.21317.1.14.2.1.10 | Columntemperature2 | read-only | current | PSU Temperature2. |
| 1.3.6.1.4.1.21317.1.14.2.1.11 | ColumnfanRPM1 | read-only | current | PSU Fan RPM1. |
| 1.3.6.1.4.1.21317.1.14.2.1.12 | ColumnfanRPM2 | read-only | current | PSU Fan RPM2. |
| 1.3.6.1.4.1.21317.1.14.2.1.13 | ColumnpsuSerialNumber | read-only | current | PSU Serial Number. |
| 1.3.6.1.4.1.21317.1.15 | ScalarfanMode | read-only | current | |
| 1.3.6.1.4.1.21317.1.16 | Nodefruinfo | |||
| 1.3.6.1.4.1.21317.1.16.1 | Nodechassis | |||
| 1.3.6.1.4.1.21317.1.16.1.1 | ScalarchassisType | read-only | current | FRU Chassis Type. |
| 1.3.6.1.4.1.21317.1.16.1.2 | ScalarchassisPartNumber | read-only | current | FRU Chassis Part Number |
| 1.3.6.1.4.1.21317.1.16.1.3 | ScalarchassisSerialNumber | read-only | current | FRU Chassis Serial Number |
| 1.3.6.1.4.1.21317.1.16.2 | Nodeboard | |||
| 1.3.6.1.4.1.21317.1.16.2.1 | ScalarboardLanguage | read-only | current | FRU Board Language |
| 1.3.6.1.4.1.21317.1.16.2.2 | ScalarboardManufacturer | read-only | current | FRU Board Manufacturer |
| 1.3.6.1.4.1.21317.1.16.2.3 | ScalarboardProductName | read-only | current | FRU Board Product Name |
| 1.3.6.1.4.1.21317.1.16.2.4 | ScalarboardSerialNumber | read-only | current | FRU Board Serial Number |
| 1.3.6.1.4.1.21317.1.16.2.5 | ScalarboardPartNumber | read-only | current | FRU Board part Number |
| 1.3.6.1.4.1.21317.1.16.3 | Nodeproduct | |||
| 1.3.6.1.4.1.21317.1.16.3.1 | ScalarproductLanguage | read-only | current | FRU Product Language |
| 1.3.6.1.4.1.21317.1.16.3.2 | ScalarproductManufacturer | read-only | current | FRU Product Manufacturer |
| 1.3.6.1.4.1.21317.1.16.3.3 | ScalarproductName | read-only | current | FRU Product Name |
| 1.3.6.1.4.1.21317.1.16.3.4 | ScalarproductPartNumber | read-only | current | FRU Product Part Number |
| 1.3.6.1.4.1.21317.1.16.3.5 | ScalarproductVersion | read-only | current | FRU Product Version |
| 1.3.6.1.4.1.21317.1.16.3.6 | ScalarproductSerialNumber | read-only | current | FRU Product Serial Number |
| 1.3.6.1.4.1.21317.1.16.3.7 | ScalarproductAssetTag | read-write | current | FRU Product Asset Tag |
| 1.3.6.1.4.1.21317.1.17 | Nodentpinfo | |||
| 1.3.6.1.4.1.21317.1.17.1 | ScalartimeZone | read-only | current | Get and set time zone. Get/Set case: -1200 -1100 -1000 -0930 -0900 -0800 -0700 -0600 -0500 -0430 -0400 -0330 -0300 -0230 -0200 -0100 +0000 +0100 +0200 +0300 +0… |
| 1.3.6.1.4.1.21317.1.17.2 | ScalarntpEnable | read-only | current | Get and set NTP status. Get case: 0 : off 1 : on Set case: 0 : off 1 : on |
| 1.3.6.1.4.1.21317.1.17.3 | ScalarprimaryNTPServer | read-only | current | Get and set primary NTP server |
| 1.3.6.1.4.1.21317.1.17.4 | ScalarsecondaryNTPServer | read-only | current | Get and set secondary NTP server |
| 1.3.6.1.4.1.21317.1.17.5 | Scalardst | read-only | current | Get and set daylight saving time status Get case: 0 : off 1 : on Set case: 0 : off 1 : on |
| 1.3.6.1.4.1.21317.1.18 | TableselTable | not-accessible | current | This table displays a record of critical system events from the monitored system. |
| 1.3.6.1.4.1.21317.1.18.1 | RowselEntry | not-accessible | current | An entry event logs indicate the time when a critical condition occurred and the time it was resolved |
| 1.3.6.1.4.1.21317.1.18.1.1 | ColumnselEid | read-only | current | system event log EID |
| 1.3.6.1.4.1.21317.1.18.1.2 | ColumnselTimeStamp | read-only | current | System event log trigger time |
| 1.3.6.1.4.1.21317.1.18.1.3 | ColumnselSensorName | read-only | current | System evnet log sensor name |
| 1.3.6.1.4.1.21317.1.18.1.4 | ColumnselSensorType | read-only | current | System evnet log sensor type |
| 1.3.6.1.4.1.21317.1.18.1.5 | ColumnselDescription | read-only | current | System evnet log description |
| 1.3.6.1.4.1.21317.1.18.1.6 | ColumnselRawData | read-only | current | System evnet log raw data |
| 1.3.6.1.4.1.21317.1.19 | Nodenvme | |||
| 1.3.6.1.4.1.21317.1.19.1 | TablenvmeCtrlTbl | not-accessible | current | A list of NVMe controllers. The number of entries is given by the number of controllers. |
| 1.3.6.1.4.1.21317.1.19.1.1 | RownvmeCtrlEntry | not-accessible | current | An entry containing a particular NVMe controller information. |
| 1.3.6.1.4.1.21317.1.19.1.1.1 | ColumnnvmeCtrlPresent | read-only | current | NVMe controllor present or not. |
| 1.3.6.1.4.1.21317.1.19.1.1.2 | ColumnmaxTemp | read-only | current | The maximum temperature from all existed NVMe drives. |
| 1.3.6.1.4.1.21317.1.19.1.1.3 | ColumnmaxSlotNum | read-only | current | Maximum slot number at each group. |
| 1.3.6.1.4.1.21317.1.19.1.1.4 | Columnonboard | read-only | current | NVMe controller type. |
| 1.3.6.1.4.1.21317.1.19.1.1.5 | ColumndriverIndex | read-only | current | NVMe BPN driver index. |
| 1.3.6.1.4.1.21317.1.19.1.1.6 | ColumncpldVer | read-only | current | CPLD FW version of this NVMe controller. |
| 1.3.6.1.4.1.21317.1.19.2 | TablenvmeDriveTbl | not-accessible | current | A list of NVMe drives. The number of entries is given by the number of drives. |
| 1.3.6.1.4.1.21317.1.19.2.1 | RownvmeDriveEntry | not-accessible | current | An entry containing a particular NVMe drive information. |
| 1.3.6.1.4.1.21317.1.19.2.1.1 | ColumnslotId | read-only | current | NVMe Slot ID at one group. |
| 1.3.6.1.4.1.21317.1.19.2.1.2 | ColumngroupId | read-only | current | Group ID at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.3 | ColumnnvmeDrivePresent | read-only | current | NVMe drive presence at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.4 | Columnlocate | read-only | current | NVMe drive locate/dislocate status at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.5 | Columnsave2Remove | read-only | current | NVMe drive save2Remove status at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.6 | ColumnvmdMode | read-only | current | NVMe drive vmdMode status at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.7 | Columntemp | read-only | current | NVMe drive temperature at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.8 | ColumnclassCode | read-only | current | NVMe drive class code at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.9 | ColumnvendorID | read-only | current | NVMe drive class code at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.10 | ColumnserialNum | read-only | current | NVMe drive serial number at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.11 | ColumnmodelNum | read-only | current | NVMe drive model number at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.12 | Columnport0MaxLinkSpd | read-only | current | NVMe drive port0 max link speed at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.13 | Columnport0MaxLinkWidth | read-only | current | NVMe drive port0 max link width at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.14 | Columnport1MaxLinkSpd | read-only | current | NVMe drive port1 max link speed at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.15 | Columnport1MaxLinkWidth | read-only | current | NVMe drive port1 max link width at this slot. |
| 1.3.6.1.4.1.21317.1.19.2.1.16 | ColumninitPowerRequirement | read-only | current | Initial power requirment (Watts). |
| 1.3.6.1.4.1.21317.1.19.2.1.17 | ColumnmaxPowerRequirement | read-only | current | Maximum power requirment (Watts). |
| 1.3.6.1.4.1.21317.1.20 | TablenicTable | not-accessible | current | A list of NICs. The number of entries is given by the number of NICs. |
| 1.3.6.1.4.1.21317.1.20.1 | RownicEntry | not-accessible | current | An entry containing management information applicable to a particular NIC. |
| 1.3.6.1.4.1.21317.1.20.1.1 | ColumnnicNumber | read-only | current | A unique value, greater than zero, for each NIC. It is recommended that values are assigned contiguously starting from 1. |
| 1.3.6.1.4.1.21317.1.20.1.2 | ColumnnicName | read-only | current | Name of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.3 | ColumnnicMac | read-only | current | MAC of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.4 | ColumnnicIpv4Addr | read-only | current | IPv4 address of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.5 | ColumnnicIpv6Addr | read-only | current | IPv6 address of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.6 | ColumnnicGateway | read-only | current | Gateway of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.7 | ColumnnicNetmask | read-only | current | Netmask of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.8 | ColumnnicFqdn | read-only | current | FQDN of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.9 | ColumnnicDns | read-only | current | DNS of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.10 | ColumnnicSpeed | read-only | current | Speed of the NIC. (Unit: Mbps) |
| 1.3.6.1.4.1.21317.1.20.1.11 | ColumnnicDescript | read-only | current | Description of the NIC. |
| 1.3.6.1.4.1.21317.1.20.1.12 | ColumnnicStatus | read-only | current | Status of the NIC. |
| 1.3.6.1.4.1.21317.1.21 | Nodenetwork | |||
| 1.3.6.1.4.1.21317.1.21.1 | Scalaripv4DNSServer | read-only | current | IPv4 dns server. |
| 1.3.6.1.4.1.21317.1.21.2 | Scalaripv4Gateway | read-only | current | IPv4 gateway |
| 1.3.6.1.4.1.21317.1.21.3 | Scalaripv6DNSServer | read-only | current | IPv6 dns server. |
| 1.3.6.1.4.1.21317.1.21.4 | Scalaripv6DUID | read-only | current | IPv6 DUID |
| 1.3.6.1.4.1.21317.1.21.5 | Scalardhcpv6State | read-only | current | DHCPv6 State |
| 1.3.6.1.4.1.21317.1.21.6 | Scalarhostname | read-only | current | BMC hostname |
| 1.3.6.1.4.1.21317.1.21.7 | ScalardhcpEnabled | read-only | current | DHCP enabled |
| 1.3.6.1.4.1.21317.1.21.8 | ScalarvlanIDEnabled | read-only | current | VLan enabled |
| 1.3.6.1.4.1.21317.1.21.9 | ScalarvlanID | read-only | current | Vlan ID |
| 1.3.6.1.4.1.21317.1.21.10 | ScalarlanInterface | read-only | current | the current Lan interface |
| 1.3.6.1.4.1.21317.1.21.11 | ScalarrmcpPort | read-only | current | IPMI port number |
| 1.3.6.1.4.1.21317.1.21.12 | ScalaractiveLanInterface | read-only | current | which Lan interface is active. |
| 1.3.6.1.4.1.21317.1.21.13 | ScalardedicatedLanDuplex | read-only | current | Duplex Mode of the dedicated Lan |
| 1.3.6.1.4.1.21317.1.21.14 | ScalarsharedLanDuplex | read-only | current | Duplex Mode of the share Lan |
| 1.3.6.1.4.1.21317.1.22 | Nodesmtp | |||
| 1.3.6.1.4.1.21317.1.22.1 | ScalarsmtpEnabled | read-only | current | enable Email server |
| 1.3.6.1.4.1.21317.1.22.2 | ScalarsmtpServer | read-only | current | Email server |
| 1.3.6.1.4.1.21317.1.22.3 | ScalarsmtpPort | read-only | current | the port number of the email server |
| 1.3.6.1.4.1.21317.1.22.4 | ScalarsmtpUsername | read-only | current | the username for email server's authentication |
| 1.3.6.1.4.1.21317.1.22.5 | ScalarsmtpSenderEmail | read-only | current | the sender's email address |
| 1.3.6.1.4.1.21317.1.23 | ScalarmouseMode | read-only | current | the port number of the email server |
| 1.3.6.1.4.1.21317.1.24 | ScalarsysBootOrder | read-write | current | One time change system boot order. |
| 1.3.6.1.4.1.21317.1.30 | Notificationguid | current | GUID. |