MIB Viewer

ATEN-PE-CFG

370 objects
ATEN PE MIB
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises Gauge IpAddress TimeTicks
RFC1213-MIBDisplayString
SNMP-USER-BASED-SM-MIBKeyChange
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.21317IdentityatenATEN PE MIB
1.3.6.1.4.1.21317.1NodeatenProducts
1.3.6.1.4.1.21317.1.3Nodeoverip
1.3.6.1.4.1.21317.1.3.2Nodepoweroverip
1.3.6.1.4.1.21317.1.3.2.2Nodepe
1.3.6.1.4.1.21317.1.3.2.2.1NodeuserManagement
1.3.6.1.4.1.21317.1.3.2.2.1.1TableusrListTablenot-accessiblecurrentA list of user. The number of user is given by the value of usrcfgNumber.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1RowusrListEntrynot-accessiblecurrentStatus and parameter values for a pe8208 user.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.1ColumnusrIndexread-onlycurrentThe value of usrIndex for the user. We have 1 administrator and 8 users. The index 9 will be the administrator.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.2ColumnusrTyperead-onlycurrentThe user's type.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.3ColumnusrNameread-writecurrentA textual string containing name of the user. string length: 1~16
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.4ColumnusrPasswordread-writecurrentA textual string containing password of the user. string length: 1~16
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.5ColumnusrPort1Authread-writecurrentDisplay or set this user's outlet 1 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.6ColumnusrPort2Authread-writecurrentDisplay or set this user's outlet 2 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.7ColumnusrPort3Authread-writecurrentDisplay or set this user's outlet 3 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.8ColumnusrPort4Authread-writecurrentDisplay or set this user's outlet 4 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.9ColumnusrPort5Authread-writecurrentDisplay or set this user's outlet 5 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.10ColumnusrPort6Authread-writecurrentDispaly or set this user's outlet 6 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.11ColumnusrPort7Authread-writecurrentDisplay or set this user's outlet 7 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.12ColumnusrPort8Authread-writecurrentDisplay or set this user's outlet 8 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.13ColumnusrPort9Authread-writecurrentDisplay or set this user's outlet 9 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.14ColumnusrPort10Authread-writecurrentDisplay or set this user's outlet 10 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.15ColumnusrPort11Authread-writecurrentDisplay or set this user's outlet 11 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.16ColumnusrPort12Authread-writecurrentDisplay or set this user's outlet 12 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.17ColumnusrPort13Authread-writecurrentDisplay or set this user's outlet 13 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.18ColumnusrPort14Authread-writecurrentDisplay or set this user's outlet 14 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.19ColumnusrPort15Authread-writecurrentDisplay or set this user's outlet 15 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.20ColumnusrPort16Authread-writecurrentDisplay or set this user's outlet 16 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.21ColumnusrPort17Authread-writecurrentDisplay or set this user's outlet 17 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.22ColumnusrPort18Authread-writecurrentDisplay or set this user's outlet 18 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.23ColumnusrPort19Authread-writecurrentDisplay or set this user's outlet 19 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.24ColumnusrPort20Authread-writecurrentDisplay or set this user's outlet 20 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.25ColumnusrPort21Authread-writecurrentDisplay or set this user's outlet 21 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.26ColumnusrPort22Authread-writecurrentDisplay or set this user's outlet 22 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.27ColumnusrPort23Authread-writecurrentDisplay or set this user's outlet 23 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.28ColumnusrPort24Authread-writecurrentDisplay or set this user's outlet 24 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.29ColumnusrPort25Authread-writecurrentDisplay or set this user's outlet 25 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.30ColumnusrPort26Authread-writecurrentDisplay or set this user's outlet 26 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.31ColumnusrPort27Authread-writecurrentDisplay or set this user's outlet 27 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.32ColumnusrPort28Authread-writecurrentDisplay or set this user's outlet 28 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.33ColumnusrPort29Authread-writecurrentDisplay or set this user's outlet 29 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.34ColumnusrPort30Authread-writecurrentDisplay or set this user's outlet 30 authority. Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.35ColumnusrPort31Authread-writecurrentDisplay or set this user's outlet 31 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.36ColumnusrPort32Authread-writecurrentDisplay or set this user's outlet 32 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.37ColumnusrPort33Authread-writecurrentDisplay or set this user's outlet 33 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.38ColumnusrPort34Authread-writecurrentDisplay or set this user's outlet 34 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.39ColumnusrPort35Authread-writecurrentDisplay or set this user's outlet 35 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.40ColumnusrPort36Authread-writecurrentDisplay or set this user's outlet 36 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.41ColumnusrPort37Authread-writecurrentDisplay or set this user's outlet 37 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.42ColumnusrPort38Authread-writecurrentDisplay or set this user's outlet 38 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.43ColumnusrPort39Authread-writecurrentDisplay or set this user's outlet 39 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.44ColumnusrPort40Authread-writecurrentDisplay or set this user's outlet 40 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.45ColumnusrPort41Authread-writecurrentDisplay or set this user's outlet 41 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.46ColumnusrPort42Authread-writecurrentDisplay or set this user's outlet 42 authority Port in the pe of series represents outlet. Port in the Energy monitor of series represents a bank or a pdu.
1.3.6.1.4.1.21317.1.3.2.2.1.1.1.47ColumnusrEnableread-writecurrentDisplay or set this user is enable or not
1.3.6.1.4.1.21317.1.3.2.2.2Nodecontrol
1.3.6.1.4.1.21317.1.3.2.2.2.1Nodedevice
1.3.6.1.4.1.21317.1.3.2.2.2.1.1ScalarmodelNameread-onlycurrentIndicate PE device model name.
1.3.6.1.4.1.21317.1.3.2.2.2.1.2ScalardeviceNameread-writecurrentThe name of PE device. string length: 1~39 NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3TabledeviceValueTablenot-accessiblecurrentDevice value table. This table displays device's current, voltage, power and power dissipation.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1RowdeviceValueEntrynot-accessiblecurrentSingle deviceValue entry containing device info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.1ColumndeviceValueIndexread-onlycurrentIndex of deviceValue.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.2ColumndeviceCurrentread-onlycurrentDevice electric current value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.3ColumndeviceVoltageread-onlycurrentDevice voltage value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.4ColumndevicePowerread-onlycurrentDevice power value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.5ColumndevicePowerDissipationread-onlycurrentDevice power dissipation value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.6ColumninputMaxVoltageread-onlycurrentDevice input Voltage value. unit:(V) If the device does not support this OID, we show value 0.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.7ColumninputMaxCurrentread-onlycurrentDevice input Current value. unit:(A) If the device does not support this OID, we show value 0.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.8ColumnpowerCapacityread-onlycurrentDevice power Capacity value.unit:(VA) If the device does not support this OID, we show value 0.
1.3.6.1.4.1.21317.1.3.2.2.2.1.3.1.9ColumndevicePowerFactorread-onlycurrentDevice power Factor value. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.4TablesensorValueTablenot-accessiblecurrentDevice's sensor value table. This table displays sensor's temperature, humidity and pressure.
1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1RowsensorValueEntrynot-accessiblecurrentSingle device's sensor value entry containing device info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.1ColumnsensorValueIndexread-onlycurrentIndex of sensor number.
1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.2ColumnsensorTemperatureread-onlycurrentSensor's Temperature value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.3ColumnsensorHumidityread-onlycurrentSensor's Humidity value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.4ColumnsensorPressureread-onlycurrentSensor's Pressure value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.1.4.1.5ColumnsensorPropertyread-onlycurrentSensor's Property.
1.3.6.1.4.1.21317.1.3.2.2.2.1.5TabledeviceOutletStatusTablenot-accessiblecurrentDevice outlet status value table.
1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1RowdeviceOutletStatusEntrynot-accessiblecurrentSingle deviceOutletStatus entry containing device info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.1ColumndeviceOutletStatusIndexread-onlycurrentIndex of deviceOutletStatus
1.3.6.1.4.1.21317.1.3.2.2.2.1.5.1.2ColumndisplayOutletStatusread-onlycurrentDisplay outlet status.
1.3.6.1.4.1.21317.1.3.2.2.2.1.6TabledeviceConfigTablenot-accessiblecurrentDevice configuration table
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1RowdeviceConfigEntrynot-accessiblecurrentSingle deviceConfig entry containing device info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.1ColumndeviceConfigIndexread-onlycurrentIndex of deviceConfig
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.2ColumndeviceMinCurMTread-writecurrentDisplay or set device minimum electric current measurement threshold. Example: range 0.0~32.0 represents 0~320. NOTICE: Minimum threshold should be smaller tha…
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.3ColumndeviceMaxCurMTread-writecurrentDisplay or set device maximum electric current measurement threshold. Example: range 0.0~32.0 represents 0~320 NOTICE: Minimum threshold should be smaller than…
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.4ColumndeviceMinVolMTread-writecurrentDisplay or set device minimum voltage measurement threshold. Exapmple: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than ma…
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.5ColumndeviceMaxVolMTread-writecurrentDisplay or set device maximum voltage measurement threshold. Example: range 90.0~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than max…
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.6ColumndeviceMinPMTread-writecurrentDisplay or set device minimum power measurement threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maxi…
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.7ColumndeviceMaxPMTread-writecurrentDisplay or set device maximum power measurement threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than maxi…
1.3.6.1.4.1.21317.1.3.2.2.2.1.6.1.8ColumndeviceMaxPDMTread-writecurrentDisplay or set device maximum power dissipation measurement threshold. Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be sma…
1.3.6.1.4.1.21317.1.3.2.2.2.1.7TabledeviceSensorTresholdTablenot-accessiblecurrentDevice environment value table
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1RowdeviceSensorTresholdEntrynot-accessiblecurrentDevice's sensor Environment entry containing sensor info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.1ColumndeviceSensorTresholdIndexread-onlycurrentIndex of sensor number
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.2ColumnsensorMinTempMTread-writecurrentDisplay or set sensor minimum temperature measurement threshold. Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller th…
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.3ColumnsensorMaxTempMTread-writecurrentDisplay or set sensor maximum temperature measurement threshold. Example: range -20.0 ~ 60.0 represents -200~600 NOTICE: Minimum threshold should be smaller th…
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.4ColumnsensorMinHumMTread-writecurrentDisplay or set sensor minimum humidity measurement threshold. Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than ma…
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.5ColumnsensorMaxHumMTread-writecurrentDisplay or set sensor maximum humidity measurement threshold. Example: range 10.0 ~ 95.0 represents 100~950 NOTICE: Minimum threshold should be smaller than ma…
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.6ColumnsensorMinPressMTread-writecurrentDisplay or set sensor minimum pressure measurement threshold. Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller…
1.3.6.1.4.1.21317.1.3.2.2.2.1.7.1.7ColumnsensorMaxPressMTread-writecurrentDisplay or set sensor maximum pressure measurement threshold. Example: range -250.0 ~ 250.0 represents -2500 ~ 2500 NOTICE: Minimum threshold should be smaller…
1.3.6.1.4.1.21317.1.3.2.2.2.1.8ScalardeviceOutletControlread-writecurrentThis function is used for all outlet ports control. Set off(1) to turn off for all outlet ports. Set on(2) to turn on for all outlet ports. Get this object alw…
1.3.6.1.4.1.21317.1.3.2.2.2.1.9ScalardeviceOutletRebootread-writecurrentThis function is used for all outlet ports to reboot. Only when outlet status is ON can do outlet reboot action to all ports. Set yes(2) to reboot all outlet p…
1.3.6.1.4.1.21317.1.3.2.2.2.1.10Scalarswitchableread-onlycurrentOutlet is switchable or not.
1.3.6.1.4.1.21317.1.3.2.2.2.1.11Scalarperportreadingread-onlycurrentOutlet is per-port reading or not.
1.3.6.1.4.1.21317.1.3.2.2.2.1.12Scalarsensornumberread-onlycurrentSensor number.
1.3.6.1.4.1.21317.1.3.2.2.2.1.13Scalaroutletnumberread-onlycurrentOutlet number.
1.3.6.1.4.1.21317.1.3.2.2.2.1.14Scalarbanknumberread-onlycurrentBank number.
1.3.6.1.4.1.21317.1.3.2.2.2.1.15TabledryContactTablenot-accessiblecurrentDevice's Dry Contact table.
1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1RowdryContactEntrynot-accessiblecurrentSingle device's dry contact value entry containing device info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.1ColumndryContactIndexread-onlycurrentIndex of dry contact number.
1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.2ColumndryContactStatusread-onlycurrentDisplay dry contact status. close(0) represents door close. open(1) represents door open. not-attached(2) represents door sensor don't attach to device.
1.3.6.1.4.1.21317.1.3.2.2.2.1.15.1.3ColumndryContactTyperead-writecurrentDry contact Type Selection
1.3.6.1.4.1.21317.1.3.2.2.2.1.17Nodepop
1.3.6.1.4.1.21317.1.3.2.2.2.1.17.1ScalarenablePOPmoderead-writecurrentEnable/Disable POP mode.
1.3.6.1.4.1.21317.1.3.2.2.2.1.17.2ScalarpopThresholdread-writecurrent(-1)means default value same as Bank Max Current 16 A. Example: range 0.0~32.0 represents 0~320 You can define the POP threshold or set as default(-1) value.
1.3.6.1.4.1.21317.1.3.2.2.2.1.17.3ScalarenableOutletPOPmoderead-writecurrentEnable/Disable Outlet POP mode.
1.3.6.1.4.1.21317.1.3.2.2.2.1.17.4ScalarenableLIFOPOPmoderead-writecurrentEnable/Disable LIFO POP mode.
1.3.6.1.4.1.21317.1.3.2.2.2.1.17.5ScalarenablePriorityPOPmoderead-writecurrentEnable/Disable Priority POP mode.
1.3.6.1.4.1.21317.1.3.2.2.2.1.17.6ScalarpopPriorityListread-writecurrentIndicate Outlets' power OFF priorities under Priority POP mode. Outlet Separator ',' Bank Separator '#' Assign each priority in each bank by Outlet index or ze…
1.3.6.1.4.1.21317.1.3.2.2.2.1.18Nodecap
1.3.6.1.4.1.21317.1.3.2.2.2.1.18.1ScalarenableCAPmoderead-writecurrentEnable/Disable CAP mode.
1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2TableoutletCAPTablenot-accessiblecurrentOutlet CAP table
1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1RowoutletCAPEntrynot-accessiblecurrentOutlet CAP entry containing CAP info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.1ColumnoutletCAPIndexread-onlycurrentIndex of outlet's CAP configuration
1.3.6.1.4.1.21317.1.3.2.2.2.1.18.2.1.2ColumnoutletCAPPriorityread-writecurrentDisplay or set the CAP Priority of outlet. Priority 0 means this outlet does not support this OID.
1.3.6.1.4.1.21317.1.3.2.2.2.1.19ScalaroutletInitModeread-writecurrentchoose outlet init mode you want.
1.3.6.1.4.1.21317.1.3.2.2.2.1.20ScalaroutletSequentialRebootread-writecurrentThis function is used to enable or disable all outlet ports to sequential reboot.
1.3.6.1.4.1.21317.1.3.2.2.2.1.99TabledeviceIntegerValueTablenot-accessiblecurrentDevice value table. This table displays device's current, voltage, power and power dissipation.
1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1RowdeviceIntegerValueEntrynot-accessiblecurrentSingle deviceValue entry containing device info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.1ColumndeviceIntegerValueIndexread-onlycurrentIndex of deviceValue.
1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.2ColumndeviceIntegerCurrentread-onlycurrentDevice electric current value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.3ColumndeviceIntegerVoltageread-onlycurrentDevice voltage value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.4ColumndeviceIntegerPowerread-onlycurrentDevice power value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.1.99.1.5ColumndeviceIntegerPowerDissipationread-onlycurrentDevice power dissipation value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.1.100TablesensorIntegerValueTablenot-accessiblecurrentDevice's sensor value table. This table displays sensor's temperature, humidity and pressure.
1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1RowsensorIntegerValueEntrynot-accessiblecurrentSingle device's sensor value entry containing device info.
1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.1ColumnsensorIntegerValueIndexread-onlycurrentIndex of sensor number.
1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.2ColumnsensorIntegerTemperatureread-onlycurrentSensor's Temperature value. This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does no…
1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.3ColumnsensorIntegerHumidityread-onlycurrentSensor's Humidity value. This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not s…
1.3.6.1.4.1.21317.1.3.2.2.2.1.100.1.4ColumnsensorIntegerPressureread-onlycurrentSensor's Pressure value. This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not s…
1.3.6.1.4.1.21317.1.3.2.2.2.2Nodeoutlet
1.3.6.1.4.1.21317.1.3.2.2.2.2.1TableoutletValueTablenot-accessiblecurrentDisplay total outlet value table
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1RowoutletValueEntrynot-accessiblecurrentSingle outletValue entry containing outlet info.
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.1ColumnoutletValueIndexread-onlycurrentIndex of outlet number
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.2ColumnoutletCurrentread-onlycurrentOutlet electric current value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.3ColumnoutletVoltageread-onlycurrentOutlet voltage value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.4ColumnoutletPowerread-onlycurrentOutlet power value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.5ColumnoutletPowerDissipationread-onlycurrentOutlet power dissipation value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.6ColumnoutletMaxCurrentread-onlycurrentOutlet Max Current value. unit: (A). If the device does not support this OID, we show value 0.
1.3.6.1.4.1.21317.1.3.2.2.2.2.1.1.7ColumnoutletPowerFactorread-onlycurrentOutlet Power Factor value. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.2.2Scalaroutlet1Statusread-writecurrentDisplay and control outlet 1 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.3Scalaroutlet2Statusread-writecurrentDisplay and control outlet 2 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.4Scalaroutlet3Statusread-writecurrentDisplay and control outlet 3 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.5Scalaroutlet4Statusread-writecurrentDisplay and control outlet 4 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.6Scalaroutlet5Statusread-writecurrentDisplay and control outlet 5 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.7Scalaroutlet6Statusread-writecurrentDisplay and control outlet 6 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.8Scalaroutlet7Statusread-writecurrentDisplay and control outlet 7 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.9Scalaroutlet8Statusread-writecurrentDisplay and control outlet 8 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.10TableoutletConfigTablenot-accessiblecurrentOutlet configuration table
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1RowoutletConfigEntrynot-accessiblecurrentOutlet Config entry containing outlet info.
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.1ColumnoutletConfigIndexread-onlycurrentIndex of outlet number
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.2ColumnoutletNameread-writecurrentDisplay or set the name of outlet. If the device does not support this OID, we show n/a. string length: 0~48 NOTE: Input string as /empty to set this object to…
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.3ColumnoutletConfirmationread-writecurrentDisplay or set the confirmation of outlet.
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.4ColumnoutletOnDelayTimeread-writecurrentDisplay or set the ON delay time of outlet. When this model does not support the OID, we show value -1.
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.5ColumnoutletOffDelayTimeread-writecurrentDisplay or set the OFF delay time of outlet. When this model does not support the OID, we show value -1.
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.6ColumnoutletShutdownMethodread-writecurrentDisplay or set the shutdown mehtod of outlet.
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.7ColumnoutletMACread-writecurrentDisplay or set the MAC address of ShutdownMethod. If the device does not support this OID, we show n/a. string length: 12
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.8ColumnoutletMinCurMTread-writecurrentDisplay or set the outlet minimum electric current measurment threshold. Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller …
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.9ColumnoutletMaxCurMTread-writecurrentDisplay or set the outlet maximum electric current measurment threshold. Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller …
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.10ColumnoutletMinVolMTread-writecurrentDisplay or set the outlet minimum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than…
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.11ColumnoutletMaxVolMTread-writecurrentDisplay or set the outlet maximum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than…
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.12ColumnoutletMinPMTread-writecurrentDisplay or set the outlet minimum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than m…
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.13ColumnoutletMaxPMTread-writecurrentDisplay or set the outlet maximum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than m…
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.14ColumnoutletMaxPDMTread-writecurrentDisplay or set the outlet maximum power dissipation measurment threshold. Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be …
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.15ColumnoutletLocalAccessLockread-writecurrentWhether local access of Outlet is locked by remote or not.
1.3.6.1.4.1.21317.1.3.2.2.2.2.10.1.16ColumnoutletAlwaysONread-writecurrentWhether the outlet is always ON or not.
1.3.6.1.4.1.21317.1.3.2.2.2.2.11Scalaroutlet9Statusread-writecurrentDisplay and control outlet 9 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.12Scalaroutlet10Statusread-writecurrentDisplay and control outlet 10 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.13Scalaroutlet11Statusread-writecurrentDisplay and control outlet 11 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.14Scalaroutlet12Statusread-writecurrentDisplay and control outlet 12 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.15Scalaroutlet13Statusread-writecurrentDisplay and control outlet 13 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.16Scalaroutlet14Statusread-writecurrentDisplay and control outlet 14 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.17Scalaroutlet15Statusread-writecurrentDisplay and control outlet 15 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.18Scalaroutlet16Statusread-writecurrentDisplay and control outlet 16 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.19Scalaroutlet17Statusread-writecurrentDisplay and control outlet 17 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.20Scalaroutlet18Statusread-writecurrentDisplay and control outlet 18 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.21Scalaroutlet19Statusread-writecurrentDisplay and control outlet 19 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.22Scalaroutlet20Statusread-writecurrentDisplay and control outlet 20 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.23Scalaroutlet21Statusread-writecurrentDisplay and control outlet 21 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.24Scalaroutlet22Statusread-writecurrentDisplay and control outlet 22 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.25Scalaroutlet23Statusread-writecurrentDisplay and control outlet 23 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.26Scalaroutlet24Statusread-writecurrentDisplay and control outlet 24 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.27Scalaroutlet25Statusread-writecurrentDisplay and control outlet 25 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.28Scalaroutlet26Statusread-writecurrentDisplay and control outlet 26 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.29Scalaroutlet27Statusread-writecurrentDisplay and control outlet 27 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.30Scalaroutlet28Statusread-writecurrentDisplay and control outlet 28 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.31Scalaroutlet29Statusread-writecurrentDisplay and control outlet 29 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.32Scalaroutlet30Statusread-writecurrentDisplay and control outlet 30 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.33Scalaroutlet31Statusread-writecurrentDisplay and control outlet 31 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.34Scalaroutlet32Statusread-writecurrentDisplay and control outlet 32 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.35Scalaroutlet33Statusread-writecurrentDisplay and control outlet 33 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.36Scalaroutlet34Statusread-writecurrentDisplay and control outlet 34 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.37Scalaroutlet35Statusread-writecurrentDisplay and control outlet 35 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.38Scalaroutlet36Statusread-writecurrentDisplay and control outlet 36 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.39Scalaroutlet37Statusread-writecurrentDisplay and control outlet 37 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.40Scalaroutlet38Statusread-writecurrentDisplay and control outlet 38 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.41Scalaroutlet39Statusread-writecurrentDisplay and control outlet 39 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.42Scalaroutlet40Statusread-writecurrentDisplay and control outlet 40 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.43Scalaroutlet41Statusread-writecurrentDisplay and control outlet 41 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.44Scalaroutlet42Statusread-writecurrentDisplay and control outlet 42 status. Can't set pending status.
1.3.6.1.4.1.21317.1.3.2.2.2.2.70TableoutletSwitchableTablenot-accessiblecurrent
1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1RowoutletSwitchableEntrynot-accessiblecurrent
1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.1ColumnoutletSwitchableIndexread-onlycurrentIndex of outlet number.
1.3.6.1.4.1.21317.1.3.2.2.2.2.70.1.2ColumnoutletSwitchableread-onlycurrent
1.3.6.1.4.1.21317.1.3.2.2.2.2.99TableoutletIntegerValueTablenot-accessiblecurrentDisplay total outlet value table
1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1RowoutletIntegerValueEntrynot-accessiblecurrentSingle outletValue entry containing outlet info.
1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.1ColumnoutletIntegerValueIndexread-onlycurrentIndex of outlet number.
1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.2ColumnoutletIntegerCurrentread-onlycurrentOutlet electric current value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.3ColumnoutletIntegerVoltageread-onlycurrentOutlet voltage value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.4ColumnoutletIntegerPowerread-onlycurrentOutlet power value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.2.99.1.5ColumnoutletIntegerPowerDissipationread-onlycurrentOutlet power dissipation value. This value indicates that 1,000 times. If the device does not support this OID, it returns value -2000000.
1.3.6.1.4.1.21317.1.3.2.2.2.3Nodebank
1.3.6.1.4.1.21317.1.3.2.2.2.3.1TablebreakerStatusTablenot-accessiblecurrentDisplay total bank value table
1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1RowbreakerStatusEntrynot-accessiblecurrentSingle bankValue entry containing bank info.
1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.1ColumnbreakerStatusIndexread-onlycurrentIndex of breaker number.
1.3.6.1.4.1.21317.1.3.2.2.2.3.1.1.2ColumnbreakerStatusread-onlycurrentBreaker status.
1.3.6.1.4.1.21317.1.3.2.2.2.3.2TablebankValueTablenot-accessiblecurrentDisplay total bank value table
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1RowbankValueEntrynot-accessiblecurrentSingle bankValue entry containing bank info.
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.1ColumnbankValueIndexread-onlycurrentIndex of bank number
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.2ColumnbankCurrentread-onlycurrentBank electric current value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.3ColumnbankVoltageread-onlycurrentBank voltage value. We put this OID to write access type for user to set the reference voltage on EC1000 model. And the setting should be the numbers. You can …
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.4ColumnbankPowerread-onlycurrentBank power value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.5ColumnbankPowerDissipationread-onlycurrentBank power dissipation value. If this measurement value is not available, it returns: N/A. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.6ColumnbankMaxCurrentread-onlycurrentThe Bank Max Current value. unit: (A) EC1000:0A~320A
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.7ColumnbankAttachStatusread-onlycurrentThe status of Energy sensor Bank attached status.
1.3.6.1.4.1.21317.1.3.2.2.2.3.2.1.8ColumnbankPowerFactorread-onlycurrentBank Power Factor value. If the device does not support this OID, it returns: not-support.
1.3.6.1.4.1.21317.1.3.2.2.2.3.3TablebankConfigTablenot-accessiblecurrentBank configuration table
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1RowbankConfigEntrynot-accessiblecurrentBank Config entry containing Bank info.
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.1ColumnbankConfigIndexread-onlycurrentIndex of bank number
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.2ColumnbankNameread-writecurrentDisplay or set the name of bank. When this model does not support the OID, we show n/a. string length: 0~15 NOTE: Input string as /empty to set this object to …
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.3ColumnbankMinCurMTread-writecurrentDisplay or set the outlet minimum electric current measurment threshold. Example: range 0.0 ~16.0 rerpresnts 0~160 NOTICE: Minimum threshold should be smaller …
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.4ColumnbankMaxCurMTread-writecurrentDisplay or set the outlet maximum electric current measurment threshold. Example: range 0.0 ~16.0 represents 0~160 NOTICE: Minimum threshold should be smaller …
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.5ColumnbankMinVolMTread-writecurrentDisplay or set the outlet minimum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than…
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.6ColumnbankMaxVolMTread-writecurrentDisplay or set the outlet maximum voltage measurment threshold. Example: range 90.0 ~260.0 represents 900~2600 NOTICE: Minimum threshold should be smaller than…
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.7ColumnbankMinPMTread-writecurrentDisplay or set the outlet minimum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than m…
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.8ColumnbankMaxPMTread-writecurrentDisplay or set the outlet maximum power measurment threshold. Example: range 0.0 ~ 9999.9 represents 0~99999 NOTICE: Minimum threshold should be smaller than m…
1.3.6.1.4.1.21317.1.3.2.2.2.3.3.1.9ColumnbankMaxPDMTread-writecurrentDisplay or set the outlet maximum power dissipation measurment threshold. Example: range 0.0 ~ 99999.0 represents 0~999990 NOTICE: Minimum threshold should be …
1.3.6.1.4.1.21317.1.3.2.2.2.3.4TablebankControlTablenot-accessiblecurrentBank Control table
1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1RowbankControlEntrynot-accessiblecurrentBank control entry.
1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.1ColumnbankControlIndexread-onlycurrentIndex of bank number
1.3.6.1.4.1.21317.1.3.2.2.2.3.4.1.2ColumnbankControlStatusread-writecurrentThis function is used for outlet control of bank. Set off(1) to turn off for outlet control of bank. Set on(2) to turn on for all outlet control of bank. Set r…
1.3.6.1.4.1.21317.1.3.2.2.2.3.99TablebankIntegerValueTablenot-accessiblecurrentDisplay total bank value table
1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1RowbankIntegerValueEntrynot-accessiblecurrentSingle bankValue entry containing bank info.
1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.1ColumnbankIntegerValueIndexread-onlycurrentIndex of bank number.
1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.2ColumnbankIntegerCurrentread-onlycurrentBank electric current value. This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does n…
1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.3ColumnbankIntegerVoltageread-onlycurrentBank voltage value. This value indicates that 1,000 times. We put this OID to write access type for user to set the reference voltage on EC1000 model. And the …
1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.4ColumnbankIntegerPowerread-onlycurrentBank power value. This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does not support …
1.3.6.1.4.1.21317.1.3.2.2.2.3.99.1.5ColumnbankIntegerPowerDissipationread-onlycurrentBank power dissipation value. This value indicates that 1,000 times. If this measurement value is not available, it returns value -1000000. If the device does …
1.3.6.1.4.1.21317.1.3.2.2.3NodedeviceManagement
1.3.6.1.4.1.21317.1.3.2.2.3.4Nodeconfig
1.3.6.1.4.1.21317.1.3.2.2.3.4.1ScalardeviceMACread-onlycurrentDisplay device MAC address.
1.3.6.1.4.1.21317.1.3.2.2.3.4.2ScalardeviceIPv4read-onlycurrentDisplay device IP address.
1.3.6.1.4.1.21317.1.3.2.2.3.4.3ScalardeviceFWversionread-onlycurrentDisplay device FW version.
1.3.6.1.4.1.21317.1.3.2.2.3.4.4NodedashBoard
1.3.6.1.4.1.21317.1.3.2.2.3.4.4.1ScalardashboardRowread-writecurrentDisplay or set device's dashboard row number.
1.3.6.1.4.1.21317.1.3.2.2.3.4.4.2ScalardashboardColumnread-writecurrentDisplay or set device's dashboard column number.
1.3.6.1.4.1.21317.1.3.2.2.3.4.4.3ScalardashboardRackNameread-writecurrentDisplay or set device's dashboard rack name. string length: 1~32 NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.5NodeservicePorts
1.3.6.1.4.1.21317.1.3.2.2.3.4.5.1ScalarhttpPortread-writecurrentDisplay or set the HTTP port of PE device.
1.3.6.1.4.1.21317.1.3.2.2.3.4.5.2ScalarhttpsPortread-writecurrentDisplay or set the HTTPs port of PE device.
1.3.6.1.4.1.21317.1.3.2.2.3.4.5.3ScalarhttpsOnlyEnableread-writecurrentEnable to use Webpage HTTPs only or disable to use Webpage HTTP/HTTPs
1.3.6.1.4.1.21317.1.3.2.2.3.4.6Nodeipv4config
1.3.6.1.4.1.21317.1.3.2.2.3.4.6.1ScalarstaticIPEnabledread-writecurrentDisplay or set IPv4 address automatically or not
1.3.6.1.4.1.21317.1.3.2.2.3.4.6.2ScalarfixedIPv4read-writecurrentDisplay or set fixed IPv4 address
1.3.6.1.4.1.21317.1.3.2.2.3.4.6.3ScalarsubnetMaskread-writecurrentDisplay or set subnet mask address
1.3.6.1.4.1.21317.1.3.2.2.3.4.6.4Scalargatewayread-writecurrentDisplay or set gateway address
1.3.6.1.4.1.21317.1.3.2.2.3.4.6.5ScalarstaticDNSEnabledread-writecurrentDisplay or set DNS address automatically or not
1.3.6.1.4.1.21317.1.3.2.2.3.4.6.6ScalardnsPreferIPv4read-writecurrentDisplay or set prefer DNS address
1.3.6.1.4.1.21317.1.3.2.2.3.4.6.7ScalardnsAlternateIPv4read-writecurrentDisplay or set alternate DNS address
1.3.6.1.4.1.21317.1.3.2.2.3.4.7NodeeventNotification
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1Nodedevicesnmp
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.1ScalartrapEnabledread-writecurrentIndicates if this trap entry is enabled or not. You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the communi…
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.2ScalartrapVersionread-writecurrentChoose SNMP Trap version to send trap. You should set the username/auth-password/priv-password first, when choosing snmpv3. You should set the community string…
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3TablesnmpTrapTablenot-accessiblecurrentPE SNMP agent trap setup table. If users want to use trap, they must set enable trap, ip and community first.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1RowsnmpTrapEntrynot-accessiblecurrentSingle trap entry containing trap receiver info.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.1ColumntrapReceiverNumberread-onlycurrentIndex of trap receiver
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.2ColumntrapReceiverIPAddressread-writecurrentTrap receiver IP address
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.3ColumntrapPortread-writecurrentNMS trap port to be used by agent to send trap
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.4ColumntrapCommunityread-writecurrentIf use SNMPv1/v2c to receive trap should set this Community string. MAX string length: 20 NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.5ColumntrapUsernameread-writecurrentIf use SNMPv3 to receive trap should set this string. NOTE: Input string as /empty to set this object to NULL. MAX string length: 20
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.6ColumntrapAuthpasswordread-writecurrentIf use SNMPv3 to receive trap should set this string. MAX string length: 20 NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.1.3.1.7ColumntrapPrivpasswordread-writecurrentIf use SNMPv3 to receive trap should set this string. MAX string length: 20 NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2Nodesyslog
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2.1ScalarsysLogServerEnabledread-writecurrentDisplay or set syslog server address automatically or not
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2.2ScalarsysLogServerIPv4read-writecurrentDisplay or set syslog server address
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.2.3ScalarsysLogServerPortread-writecurrentDisplay or set syslog server port
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3Nodesmtp
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.1ScalarsmtpServerEnabledread-writecurrentDisplay or set SMTP server enable status.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.2ScalarsmtpServerNameread-writecurrentDisplay or set a SMTP server name. NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.3ScalarsmtpAuthEnabledread-writecurrentDisplay or set authentication of SMTP server.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.4ScalarsmtpAccountNameread-writecurrentDisplay or set a user's name of SMTP server. NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.5ScalarsmtpAccountPwdread-writecurrentDisplay or set a user's password of SMTP server. NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.6ScalarsmtpMailFromread-writecurrentDisplay or set a mail of SMTP server. NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.7ScalarsmtpMailToread-writecurrentDisplay or set a mail of SMTP server. NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.3.8ScalarsmtpPortread-writecurrentDisplay or set SMTP server port
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.9NodeconfigurationNotification
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.9.1ScalarconfigurationNotifyEnabledread-writecurrent
1.3.6.1.4.1.21317.1.3.2.2.3.4.7.9.2NotificationconfigurationNotifyTrapMSGcurrent
1.3.6.1.4.1.21317.1.3.2.2.3.4.8NodedateTime
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.1NodetimeZone
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.1.1ScalartimeZoneSettingread-writecurrentDisplay or set the time zone of PE device. (0) [GMT-12:00] Eniwetok Kwajalein (1) [GMT-11:00] Midway Island Samoa (2) [GMT-10:00] Hawaii (3) [GMT-09:00] Alaska…
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.1.2ScalardstEnabledread-writecurrentDisplay or set daylight savings time .
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.2NodemanualInput
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.2.1ScalardateSettingread-writecurrentDisplay or set date in a manual way.(This is Greenwich Mean Time, GMT) string length: 10 This value format must match the following form: YYYY-MM-DD ex. 2011-0…
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.2.2ScalartimeSettingread-writecurrentDisplay or set time in a manual way.(This is Greenwich Mean Time, GMT) string length: 8 This value format must match the following form: HH:MM:SS ex. 02:02:02 …
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3NodenetworkTime
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.1ScalarautoAdjustEnabledread-writecurrentDisplay or set date time useing auto adjustment way.
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.2ScalarpreferNTPread-writecurrentDisplay or set prefer NTP server. AU | ntp1.cs.mu.OZ.AU(0), AU | ntp0.cs.mu.OZ.AU(1), BE | ntp2.oma.be(2), BE | ntp1.oma.be(3), BR | ntps1.pads.ufrj.br(4), CH …
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.3ScalarpreferServerIPenableread-writecurrentEnable or disable prefer custom server IP.
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.4ScalarpreferNTPIpread-writecurrentDisplay or set prefer NTP server IP.
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.5ScalaralternateNtpEnabledread-writecurrentDisplay or set date time using alternate NTP server.
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.6ScalaralternateNtpread-writecurrentDisplay or set alternative NTP server. AU | ntp1.cs.mu.OZ.AU(0), AU | ntp0.cs.mu.OZ.AU(1), BE | ntp2.oma.be(2), BE | ntp1.oma.be(3), BR | ntps1.pads.ufrj.br(4)…
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.7ScalaralternateServerIPenableread-writecurrentEnable or disable alternate custom server IP.
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.8ScalaralternateNtpIpread-writecurrentDisplay or set alternative NTP server IP.
1.3.6.1.4.1.21317.1.3.2.2.3.4.8.3.9ScalaradjustTimeEveryDaysread-writecurrentDisplay or set frequency of adjustment in days.
1.3.6.1.4.1.21317.1.3.2.2.3.5Nodedevicesecurity
1.3.6.1.4.1.21317.1.3.2.2.3.5.1NodeloginFailures
1.3.6.1.4.1.21317.1.3.2.2.3.5.1.1ScalarloginAllowTimesread-writecurrentDisplay or set time of login faliure.
1.3.6.1.4.1.21317.1.3.2.2.3.5.1.2ScalarloginTimeOutread-writecurrentDisplay or set login time out.
1.3.6.1.4.1.21317.1.3.2.2.3.5.2NodeworkingMode
1.3.6.1.4.1.21317.1.3.2.2.3.5.2.1ScalaricmpEnabledread-writecurrentDisplay or set status of ICMP.
1.3.6.1.4.1.21317.1.3.2.2.3.5.3NodeaccountPolicy
1.3.6.1.4.1.21317.1.3.2.2.3.5.3.1ScalarminUserNameLenread-writecurrentDisplay or set minimum length of user name.
1.3.6.1.4.1.21317.1.3.2.2.3.5.3.2ScalarminUserPwdLenread-writecurrentDisplay or set minimum length of user password.
1.3.6.1.4.1.21317.1.3.2.2.3.5.3.3ScalarupperCaseEnabledread-writecurrentDisplay or set one upper case rule in user password.
1.3.6.1.4.1.21317.1.3.2.2.3.5.3.4ScalarlowerCaseEnabledread-writecurrentDisplay or set one lower case rule in user password.
1.3.6.1.4.1.21317.1.3.2.2.3.5.3.5ScalarnumberEnabledread-writecurrentDisplay or set one number rule in user password.
1.3.6.1.4.1.21317.1.3.2.2.3.5.3.6ScalardisableDuplicateLoginread-writecurrentDisplay or set status of disabled duplicate login rule.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4NodeloginRestriction
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.1ScalarloginStringread-writecurrentDisplay or set a login string. string length: 0~32 NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2NodeipFilter
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.1ScalaripFilterEnabledread-writecurrentDisplay or set status of ip filter.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.2ScalaripFilterRuleread-writecurrentDisplay or set status of ip filter rule.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3TableipFilterTablenot-accessiblecurrentA list of restricted ip.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1RowipFilterEntrynot-accessiblecurrentStatus and parameter values for a PE's restricted IP.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.1ColumnipFilterIndexread-onlycurrentThe value of index for the ip filter.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.2ColumnipFilterFromread-writecurrentA set of restricted ip. ex. 192.168.0.1 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.2.3.1.3ColumnipFilterToread-writecurrentA set of restricted ip. ex. 192.168.0.255 Note: Users must follow in order to set the ip address. Note: To clear the settings to set the ip 0.0.0.0
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3NodemacFilter
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.1ScalarmacFilterEnabledread-writecurrentDisplay or set status of mac filter.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.2ScalarmacFilterRuleread-writecurrentDisplay or set status of mac filter rule.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3TablemacFilterTablenot-accessiblecurrentA list of restricted mac.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1RowmacFilterEntrynot-accessiblecurrentStatus and parameter values for a PE's restricted MAC.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.1ColumnmacFilterIndexread-onlycurrentThe value of index for the mac filter.
1.3.6.1.4.1.21317.1.3.2.2.3.5.4.3.3.1.2ColumnmacFilterSetread-writecurrentA set of restricted mac. string length: 12 ex. 004854655511 Note: Users must follow in order to set the MAC address. Note: To clear the settings to set the MAC…
1.3.6.1.4.1.21317.1.3.2.2.3.5.5Nodeauthentication
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1Noderadius
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.1ScalarradiusEnabledread-writecurrentDisplay or set status of RADIUS server.
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.2ScalarpreferRadiusIpread-writecurrentDisplay or set prefer RADIUS server IP.
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.3ScalarpreferRadiusPortread-writecurrentDisplay or set prefer RADIUS server port.
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.4ScalaralternateRadiusIpread-writecurrentDisplay or set alternative RADIUS server IP.
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.5ScalaralternateRadiusPortread-writecurrentDisplay or set alternative RADIUS server port.
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.6ScalarradiusTimeOutread-writecurrentDisplay or set time out of authentication using RADIUS server. The unit is sec.
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.7ScalarradiusRetryread-writecurrentDisplay or set retry times of authentication using RADIUS server.
1.3.6.1.4.1.21317.1.3.2.2.3.5.5.1.8ScalarradiusSecretread-writecurrentDisplay or set shared secret of RADIUS server. string length: 6~15 At least 6 characters. NOTE: Input string as /empty to set this object to NULL.
1.3.6.1.4.1.21317.1.3.2.2.4NodedeviceLock
1.3.6.1.4.1.21317.1.3.2.2.4.1ScalarcommunityLockread-writecurrentChange SNMPV1 or SNMPV2 community for California passes law. Please follow the format as readcommunity||writecommunity
1.3.6.1.4.1.21317.1.3.2.2.4.2ScalarpasswordLockread-writecurrentChange SNMPV3 password for California passes law. Please follow the format as authpassword||privpassword
1.3.6.1.4.1.21317.1.3.2.2.5NotificationcustomTrapMSGcurrentDisplay custom trap message.
1.3.6.1.4.1.21317.1.3.2.2.6ScalarrebootDeviceread-writecurrentReboot PE Device