Argus-MIB
217 objects
This MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: the SM-series of controllers
Imported Objects
| SNMPv2-SMI | enterprises MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7309 | Identityargus | This MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: the SM-series of controllers | ||
| 1.3.6.1.4.1.7309.4 | Nodedcpower | |||
| 1.3.6.1.4.1.7309.4.1 | NodedcPwrSysDevice | |||
| 1.3.6.1.4.1.7309.4.1.1 | NodedcPwrSysVariable | |||
| 1.3.6.1.4.1.7309.4.1.1.1 | ScalardcPwrSysChargeVolts | read-only | current | Battery Charge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt |
| 1.3.6.1.4.1.7309.4.1.1.2 | ScalardcPwrSysDischargeVolts | read-only | current | Battery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volt |
| 1.3.6.1.4.1.7309.4.1.1.3 | ScalardcPwrSysChargeAmps | read-only | current | Battery Charge Current. The integer value represent a two digit fix decimal (Value = real current * 100) in Amp |
| 1.3.6.1.4.1.7309.4.1.1.4 | ScalardcPwrSysDischargeAmps | read-only | current | Battery Discharge Current. The integer value represent a two digit fix decimal (Value = real current * 100) in Amp |
| 1.3.6.1.4.1.7309.4.1.1.5 | ScalardcPwrSysMajorAlarm | read-only | current | Major Alarm |
| 1.3.6.1.4.1.7309.4.1.1.6 | ScalardcPwrSysMinorAlarm | read-only | current | Minor Alarm |
| 1.3.6.1.4.1.7309.4.1.2 | NodedcPwrSysString | |||
| 1.3.6.1.4.1.7309.4.1.2.1 | ScalardcPwrSysSiteName | read-only | current | Site Name |
| 1.3.6.1.4.1.7309.4.1.2.2 | ScalardcPwrSysSiteCity | read-only | current | Site City |
| 1.3.6.1.4.1.7309.4.1.2.3 | ScalardcPwrSysSiteRegion | read-only | current | Site Region |
| 1.3.6.1.4.1.7309.4.1.2.4 | ScalardcPwrSysSiteCountry | read-only | current | Site Country |
| 1.3.6.1.4.1.7309.4.1.2.5 | ScalardcPwrSysContactName | read-only | current | Contact Name |
| 1.3.6.1.4.1.7309.4.1.2.6 | ScalardcPwrSysPhoneNumber | read-only | current | Phone Number |
| 1.3.6.1.4.1.7309.4.1.2.7 | ScalardcPwrSysSiteNumber | read-only | current | Site Number |
| 1.3.6.1.4.1.7309.4.1.2.8 | ScalardcPwrSysSystemType | read-only | current | The type of system being monitored by the agent |
| 1.3.6.1.4.1.7309.4.1.2.9 | ScalardcPwrSysSystemSerial | read-only | current | The serial number of the monitored system |
| 1.3.6.1.4.1.7309.4.1.2.10 | ScalardcPwrSysSystemNumber | read-only | current | The number of the monitored system |
| 1.3.6.1.4.1.7309.4.1.2.11 | ScalardcPwrSysSoftwareVersion | read-only | current | The version of software running on the monitored system |
| 1.3.6.1.4.1.7309.4.1.2.12 | ScalardcPwrSysSoftwareTimestamp | read-only | current | The time stamp of the software running on the monitored system |
| 1.3.6.1.4.1.7309.4.1.3 | NodedcPwrSysTraps | |||
| 1.3.6.1.4.1.7309.4.1.3.0 | NodedcPwrSysTrap | |||
| 1.3.6.1.4.1.7309.4.1.3.0.1 | NotificationdcPwrSysAlarmActiveTrap | current | A trap issued when one of the alarms on the DC power system controller became active | |
| 1.3.6.1.4.1.7309.4.1.3.0.2 | NotificationdcPwrSysAlarmClearedTrap | current | A trap issued when one of the active alarms on the DC power system controller is cleared | |
| 1.3.6.1.4.1.7309.4.1.3.0.3 | NotificationdcPwrSysRelayTrap | current | A trap issued from a change in state in one of the relays on the DC power system controller | |
| 1.3.6.1.4.1.7309.4.1.3.0.4 | NotificationdcPwrSysComOKTrap | current | A trap to indicate that communications with a DC power system controller has been established. | |
| 1.3.6.1.4.1.7309.4.1.3.0.5 | NotificationdcPwrSysComErrTrap | current | A trap to indicate that communications with a DC power system controller has been lost. | |
| 1.3.6.1.4.1.7309.4.1.3.0.6 | NotificationdcPwrSysAgentStartupTrap | current | A trap to indicate that the agent software has started up. | |
| 1.3.6.1.4.1.7309.4.1.3.0.7 | NotificationdcPwrSysAgentShutdownTrap | current | A trap to indicate that the agent software has shutdown. | |
| 1.3.6.1.4.1.7309.4.1.3.0.8 | NotificationdcPwrSysMajorAlarmActiveTrap | current | A trap issued as a summary of DC power system status. It is sent when the system goes into in Major Alarm | |
| 1.3.6.1.4.1.7309.4.1.3.0.9 | NotificationdcPwrSysMajorAlarmClearedTrap | current | A trap issued as a summary of DC power system status. It is sent when the system comes out of Major Alarm | |
| 1.3.6.1.4.1.7309.4.1.3.0.10 | NotificationdcPwrSysMinorAlarmActiveTrap | current | A trap issued as a summary of DC power system status. It is sent when the system goes into in Minor Alarm | |
| 1.3.6.1.4.1.7309.4.1.3.0.11 | NotificationdcPwrSysMinorAlarmClearedTrap | current | A trap issued as a summary of DC power system status. It is sent when the system comes out of Minor Alarm | |
| 1.3.6.1.4.1.7309.4.1.4 | NodedcPwrSysOutputsTbl | |||
| 1.3.6.1.4.1.7309.4.1.4.1 | NodedcPwrSysRelayTbl | |||
| 1.3.6.1.4.1.7309.4.1.4.1.1 | ScalardcPwrSysRelayCount | read-only | current | Number of relay variables in system controller relay table |
| 1.3.6.1.4.1.7309.4.1.4.1.2 | TabledcPwrSysRelayTable | not-accessible | current | A table of DC power system controller rectifier relay output variables |
| 1.3.6.1.4.1.7309.4.1.4.1.2.1 | RowdcPwrSysRelayEntry | not-accessible | current | An entry into the DC power system controller relay output group |
| 1.3.6.1.4.1.7309.4.1.4.1.2.1.1 | ColumndcPwrSysRelayIndex | read-only | current | The index of the relay variable in the power system controller relay output group |
| 1.3.6.1.4.1.7309.4.1.4.1.2.1.2 | ColumndcPwrSysRelayName | read-only | current | The description of the relay variable as reported by the DC power system controller relay output group |
| 1.3.6.1.4.1.7309.4.1.4.1.2.1.3 | ColumndcPwrSysRelayIntegerValue | read-only | current | The integer value of the relay variable as reported by the DC power system controller relay output group |
| 1.3.6.1.4.1.7309.4.1.4.1.2.1.4 | ColumndcPwrSysRelayStringValue | read-only | current | The string value of the relay variable as reported by the DC power system controller relay output group |
| 1.3.6.1.4.1.7309.4.1.4.1.2.1.5 | ColumndcPwrSysRelaySeverity | read-only | current | The integer value of relay severity level of the extra variable as reported by the DC power system controller relay output group |
| 1.3.6.1.4.1.7309.4.1.4.2 | NodedcPwrSysAnalogOpTbl | |||
| 1.3.6.1.4.1.7309.4.1.4.2.1 | ScalardcPwrSysAnalogOpCount | read-only | current | Number of analog output variables in system controller analog output table |
| 1.3.6.1.4.1.7309.4.1.4.2.2 | TabledcPwrSysAnalogOpTable | not-accessible | current | A table of DC power system controller analog output variables |
| 1.3.6.1.4.1.7309.4.1.4.2.2.1 | RowdcPwrSysAnalogOpEntry | not-accessible | current | An entry into the DC power system controller analog output group |
| 1.3.6.1.4.1.7309.4.1.4.2.2.1.1 | ColumndcPwrSysAnalogOpIndex | read-only | current | The index of the analog variable in the power system controller analog output group |
| 1.3.6.1.4.1.7309.4.1.4.2.2.1.2 | ColumndcPwrSysAnalogOpName | read-only | current | The description of the analog variable as reported by the DC power system controller analog output group |
| 1.3.6.1.4.1.7309.4.1.4.2.2.1.3 | ColumndcPwrSysAnalogOpIntegerValue | read-only | current | The integer value of the analog variable as reported by the DC power system controller analog output group |
| 1.3.6.1.4.1.7309.4.1.4.2.2.1.4 | ColumndcPwrSysAnalogOpStringValue | read-only | current | The string value of the analog variable as reported by the DC power system controller analog output group |
| 1.3.6.1.4.1.7309.4.1.4.2.2.1.5 | ColumndcPwrSysAnalogOpSeverity | read-only | current | The integer value of analog severity level of the extra variable as reported by the DC power system controller analog output group |
| 1.3.6.1.4.1.7309.4.1.5 | NodedcPwrSysAlrmsTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.1 | NodedcPwrSysRectAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.1.1 | ScalardcPwrSysRectAlrmCount | read-only | current | Number of rectifier alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.1.2 | TabledcPwrSysRectAlrmTable | not-accessible | current | A table of DC power system controller rectifier alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.1.2.1 | RowdcPwrSysRectAlrmEntry | not-accessible | current | An entry into the DC power system controller rectifier alarm group |
| 1.3.6.1.4.1.7309.4.1.5.1.2.1.1 | ColumndcPwrSysRectAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table rectifier alarm group |
| 1.3.6.1.4.1.7309.4.1.5.1.2.1.2 | ColumndcPwrSysRectAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller rectifier alarm group |
| 1.3.6.1.4.1.7309.4.1.5.1.2.1.3 | ColumndcPwrSysRectAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller rectifier alarm group |
| 1.3.6.1.4.1.7309.4.1.5.1.2.1.4 | ColumndcPwrSysRectAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller rectifier alarm group |
| 1.3.6.1.4.1.7309.4.1.5.1.2.1.5 | ColumndcPwrSysRectAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller rectifier alarm group |
| 1.3.6.1.4.1.7309.4.1.5.2 | NodedcPwrSysDigAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.2.1 | ScalardcPwrSysDigAlrmCount | read-only | current | Number of digital alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.2.2 | TabledcPwrSysDigAlrmTable | not-accessible | current | A table of DC power system controller digital alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.2.2.1 | RowdcPwrSysDigAlrmEntry | not-accessible | current | An entry into the DC power system controller digital alarm group |
| 1.3.6.1.4.1.7309.4.1.5.2.2.1.1 | ColumndcPwrSysDigAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table digital alarm group |
| 1.3.6.1.4.1.7309.4.1.5.2.2.1.2 | ColumndcPwrSysDigAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller digital alarm group |
| 1.3.6.1.4.1.7309.4.1.5.2.2.1.3 | ColumndcPwrSysDigAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller digital alarm group |
| 1.3.6.1.4.1.7309.4.1.5.2.2.1.4 | ColumndcPwrSysDigAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller digital alarm group |
| 1.3.6.1.4.1.7309.4.1.5.2.2.1.5 | ColumndcPwrSysDigAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller digital alarm group |
| 1.3.6.1.4.1.7309.4.1.5.3 | NodedcPwrSysCurrAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.3.1 | ScalardcPwrSysCurrAlrmCount | read-only | current | Number of current alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.3.2 | TabledcPwrSysCurrAlrmTable | not-accessible | current | A table of DC power system controller current alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.3.2.1 | RowdcPwrSysCurrAlrmEntry | not-accessible | current | An entry into the DC power system controller current alarm group |
| 1.3.6.1.4.1.7309.4.1.5.3.2.1.1 | ColumndcPwrSysCurrAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table current alarm group |
| 1.3.6.1.4.1.7309.4.1.5.3.2.1.2 | ColumndcPwrSysCurrAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller current alarm group |
| 1.3.6.1.4.1.7309.4.1.5.3.2.1.3 | ColumndcPwrSysCurrAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller current alarm group |
| 1.3.6.1.4.1.7309.4.1.5.3.2.1.4 | ColumndcPwrSysCurrAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller current alarm group |
| 1.3.6.1.4.1.7309.4.1.5.3.2.1.5 | ColumndcPwrSysCurrAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller current alarm group |
| 1.3.6.1.4.1.7309.4.1.5.4 | NodedcPwrSysVoltAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.4.1 | ScalardcPwrSysVoltAlrmCount | read-only | current | Number of voltage alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.4.2 | TabledcPwrSysVoltAlrmTable | not-accessible | current | A table of DC power system controller voltage alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.4.2.1 | RowdcPwrSysVoltAlrmEntry | not-accessible | current | An entry into the DC power system controller voltage alarm group |
| 1.3.6.1.4.1.7309.4.1.5.4.2.1.1 | ColumndcPwrSysVoltAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table voltage alarm group |
| 1.3.6.1.4.1.7309.4.1.5.4.2.1.2 | ColumndcPwrSysVoltAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller voltage alarm group |
| 1.3.6.1.4.1.7309.4.1.5.4.2.1.3 | ColumndcPwrSysVoltAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller voltage alarm group |
| 1.3.6.1.4.1.7309.4.1.5.4.2.1.4 | ColumndcPwrSysVoltAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller voltage alarm group |
| 1.3.6.1.4.1.7309.4.1.5.4.2.1.5 | ColumndcPwrSysVoltAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller voltage alarm group |
| 1.3.6.1.4.1.7309.4.1.5.5 | NodedcPwrSysBattAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.5.1 | ScalardcPwrSysBattAlrmCount | read-only | current | Number of battery alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.5.2 | TabledcPwrSysBattAlrmTable | not-accessible | current | A table of DC power system controller battery alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.5.2.1 | RowdcPwrSysBattAlrmEntry | not-accessible | current | An entry into the DC power system controller battery alarm group |
| 1.3.6.1.4.1.7309.4.1.5.5.2.1.1 | ColumndcPwrSysBattAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table battery alarm group |
| 1.3.6.1.4.1.7309.4.1.5.5.2.1.2 | ColumndcPwrSysBattAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller battery alarm group |
| 1.3.6.1.4.1.7309.4.1.5.5.2.1.3 | ColumndcPwrSysBattAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller battery alarm group |
| 1.3.6.1.4.1.7309.4.1.5.5.2.1.4 | ColumndcPwrSysBattAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller battery alarm group |
| 1.3.6.1.4.1.7309.4.1.5.5.2.1.5 | ColumndcPwrSysBattAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller battery alarm group |
| 1.3.6.1.4.1.7309.4.1.5.6 | NodedcPwrSysTempAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.6.1 | ScalardcPwrSysTempAlrmCount | read-only | current | Number of temperature alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.6.2 | TabledcPwrSysTempAlrmTable | not-accessible | current | A table of DC power system controller temperature alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.6.2.1 | RowdcPwrSysTempAlrmEntry | not-accessible | current | An entry into the DC power system controller temperature alarm group |
| 1.3.6.1.4.1.7309.4.1.5.6.2.1.1 | ColumndcPwrSysTempAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table temperature alarm group |
| 1.3.6.1.4.1.7309.4.1.5.6.2.1.2 | ColumndcPwrSysTempAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller temperature alarm group |
| 1.3.6.1.4.1.7309.4.1.5.6.2.1.3 | ColumndcPwrSysTempAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller temperature alarm group |
| 1.3.6.1.4.1.7309.4.1.5.6.2.1.4 | ColumndcPwrSysTempAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller temperature alarm group |
| 1.3.6.1.4.1.7309.4.1.5.6.2.1.5 | ColumndcPwrSysTempAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller temperature alarm group |
| 1.3.6.1.4.1.7309.4.1.5.7 | NodedcPwrSysCustomAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.7.1 | ScalardcPwrSysCustomAlrmCount | read-only | current | Number of custom alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.7.2 | TabledcPwrSysCustomAlrmTable | not-accessible | current | A table of DC power system controller custom alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.7.2.1 | RowdcPwrSysCustomAlrmEntry | not-accessible | current | An entry into the DC power system controller custom alarm group |
| 1.3.6.1.4.1.7309.4.1.5.7.2.1.1 | ColumndcPwrSysCustomAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table custom alarm group |
| 1.3.6.1.4.1.7309.4.1.5.7.2.1.2 | ColumndcPwrSysCustomAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller custom alarm group |
| 1.3.6.1.4.1.7309.4.1.5.7.2.1.3 | ColumndcPwrSysCustomAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller custom alarm group |
| 1.3.6.1.4.1.7309.4.1.5.7.2.1.4 | ColumndcPwrSysCustomAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller custom alarm group |
| 1.3.6.1.4.1.7309.4.1.5.7.2.1.5 | ColumndcPwrSysCustomAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller custom alarm group |
| 1.3.6.1.4.1.7309.4.1.5.8 | NodedcPwrSysMiscAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.8.1 | ScalardcPwrSysMiscAlrmCount | read-only | current | Number of misc alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.8.2 | TabledcPwrSysMiscAlrmTable | not-accessible | current | A table of DC power system controller misc alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.8.2.1 | RowdcPwrSysMiscAlrmEntry | not-accessible | current | An entry into the DC power system controller misc alarm group |
| 1.3.6.1.4.1.7309.4.1.5.8.2.1.1 | ColumndcPwrSysMiscAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table misc alarm group |
| 1.3.6.1.4.1.7309.4.1.5.8.2.1.2 | ColumndcPwrSysMiscAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller misc alarm group |
| 1.3.6.1.4.1.7309.4.1.5.8.2.1.3 | ColumndcPwrSysMiscAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller misc alarm group |
| 1.3.6.1.4.1.7309.4.1.5.8.2.1.4 | ColumndcPwrSysMiscAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller misc alarm group |
| 1.3.6.1.4.1.7309.4.1.5.8.2.1.5 | ColumndcPwrSysMiscAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller misc alarm group |
| 1.3.6.1.4.1.7309.4.1.5.9 | NodedcPwrSysCtrlAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.9.1 | ScalardcPwrSysCtrlAlrmCount | read-only | current | Number of control alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.9.2 | TabledcPwrSysCtrlAlrmTable | not-accessible | current | A table of DC power system controller control alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.9.2.1 | RowdcPwrSysCtrlAlrmEntry | not-accessible | current | An entry into the DC power system controller control alarm group |
| 1.3.6.1.4.1.7309.4.1.5.9.2.1.1 | ColumndcPwrSysCtrlAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table control alarm group |
| 1.3.6.1.4.1.7309.4.1.5.9.2.1.2 | ColumndcPwrSysCtrlAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller control alarm group |
| 1.3.6.1.4.1.7309.4.1.5.9.2.1.3 | ColumndcPwrSysCtrlAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller control alarm group |
| 1.3.6.1.4.1.7309.4.1.5.9.2.1.4 | ColumndcPwrSysCtrlAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller control alarm group |
| 1.3.6.1.4.1.7309.4.1.5.9.2.1.5 | ColumndcPwrSysCtrlAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller control alarm group |
| 1.3.6.1.4.1.7309.4.1.5.10 | NodedcPwrSysAdioAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.10.1 | ScalardcPwrSysAdioAlrmCount | read-only | current | Number of control alarm variables in Adio alarm table |
| 1.3.6.1.4.1.7309.4.1.5.10.2 | TabledcPwrSysAdioAlrmTable | not-accessible | current | A table of DC power system controller Adio alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.10.2.1 | RowdcPwrSysAdioAlrmEntry | not-accessible | current | An entry into the DC power system controller Adio alarm group |
| 1.3.6.1.4.1.7309.4.1.5.10.2.1.1 | ColumndcPwrSysAdioAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table Adio alarm group |
| 1.3.6.1.4.1.7309.4.1.5.10.2.1.2 | ColumndcPwrSysAdioAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller Adio alarm group |
| 1.3.6.1.4.1.7309.4.1.5.10.2.1.3 | ColumndcPwrSysAdioAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller Adio alarm group |
| 1.3.6.1.4.1.7309.4.1.5.10.2.1.4 | ColumndcPwrSysAdioAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller Adio alarm group |
| 1.3.6.1.4.1.7309.4.1.5.10.2.1.5 | ColumndcPwrSysAdioAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC Adio system controller control alarm group |
| 1.3.6.1.4.1.7309.4.1.5.11 | NodedcPwrSysConvAlrmTbl | |||
| 1.3.6.1.4.1.7309.4.1.5.11.1 | ScalardcPwrSysConvAlrmCount | read-only | current | Number of Converter alarm variables in system controller alarm table |
| 1.3.6.1.4.1.7309.4.1.5.11.2 | TabledcPwrSysConvAlrmTable | not-accessible | current | A table of DC power system controller Converter alarm variables |
| 1.3.6.1.4.1.7309.4.1.5.11.2.1 | RowdcPwrSysConvAlrmEntry | not-accessible | current | An entry into the DC power system controller Converter alarm group |
| 1.3.6.1.4.1.7309.4.1.5.11.2.1.1 | ColumndcPwrSysConvAlrmIndex | read-only | current | The index of the alarm variable in the DC power system controller table Converter alarm group |
| 1.3.6.1.4.1.7309.4.1.5.11.2.1.2 | ColumndcPwrSysConvAlrmName | read-only | current | The description of the alarm variable as reported by the DC power system controller Converter alarm group |
| 1.3.6.1.4.1.7309.4.1.5.11.2.1.3 | ColumndcPwrSysConvAlrmIntegerValue | read-only | current | The integer value of the alarm variable as reported by the DC power system controller Converter alarm group |
| 1.3.6.1.4.1.7309.4.1.5.11.2.1.4 | ColumndcPwrSysConvAlrmStringValue | read-only | current | The string value of the alarm variable as reported by the DC power system controller Converter alarm group |
| 1.3.6.1.4.1.7309.4.1.5.11.2.1.5 | ColumndcPwrSysConvAlrmSeverity | read-only | current | The integer value of alarm severity level of the extra variable as reported by the DC power system controller Converter alarm group |
| 1.3.6.1.4.1.7309.4.1.6 | NodedcPwrSysInputsTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.1 | NodedcPwrSysDigIpTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.1.1 | ScalardcPwrSysDigIpCount | read-only | current | Number of digital input variables in system controller digital input table |
| 1.3.6.1.4.1.7309.4.1.6.1.2 | TabledcPwrSysDigIpTable | not-accessible | current | A table of DC power system controller digital input variables |
| 1.3.6.1.4.1.7309.4.1.6.1.2.1 | RowdcPwrSysDigIpEntry | not-accessible | current | An entry into the DC power system controller digital input group |
| 1.3.6.1.4.1.7309.4.1.6.1.2.1.1 | ColumndcPwrSysDigIpIndex | read-only | current | The index of the digital input variable in the DC power system controller table digital input group |
| 1.3.6.1.4.1.7309.4.1.6.1.2.1.2 | ColumndcPwrSysDigIpName | read-only | current | The description of the digital input variable as reported by the DC power system controller digital input group |
| 1.3.6.1.4.1.7309.4.1.6.1.2.1.3 | ColumndcPwrSysDigIpIntegerValue | read-only | current | The integer value of the digital input variable as reported by the DC power system controller digital input group |
| 1.3.6.1.4.1.7309.4.1.6.1.2.1.4 | ColumndcPwrSysDigIpStringValue | read-only | current | The string value of the digital input variable as reported by the DC power system controller digital input group |
| 1.3.6.1.4.1.7309.4.1.6.2 | NodedcPwrSysCntrlrIpTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.2.1 | ScalardcPwrSysCntrlrIpCount | read-only | current | Number of controller input variables in system controller controller input table |
| 1.3.6.1.4.1.7309.4.1.6.2.2 | TabledcPwrSysCntrlrIpTable | not-accessible | current | A table of DC power system controller controller input variables |
| 1.3.6.1.4.1.7309.4.1.6.2.2.1 | RowdcPwrSysCntrlrIpEntry | not-accessible | current | An entry into the DC power system controller controller input group |
| 1.3.6.1.4.1.7309.4.1.6.2.2.1.1 | ColumndcPwrSysCntrlrIpIndex | read-only | current | The index of the controller input variable in the DC power system controller table controller input group |
| 1.3.6.1.4.1.7309.4.1.6.2.2.1.2 | ColumndcPwrSysCntrlrIpName | read-only | current | The description of the controller input variable as reported by the DC power system controller controller input group |
| 1.3.6.1.4.1.7309.4.1.6.2.2.1.3 | ColumndcPwrSysCntrlrIpIntegerValue | read-only | current | The integer value of the controller input variable as reported by the DC power system controller controller input group |
| 1.3.6.1.4.1.7309.4.1.6.2.2.1.4 | ColumndcPwrSysCntrlrIpStringValue | read-only | current | The string value of the controller input variable as reported by the DC power system controller controller input group |
| 1.3.6.1.4.1.7309.4.1.6.3 | NodedcPwrSysRectIpTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.3.1 | ScalardcPwrSysRectIpCount | read-only | current | Number of rectifier input variables in system controller rectifier input table |
| 1.3.6.1.4.1.7309.4.1.6.3.2 | TabledcPwrSysRectIpTable | not-accessible | current | A table of DC power system controller rectifier input variables |
| 1.3.6.1.4.1.7309.4.1.6.3.2.1 | RowdcPwrSysRectIpEntry | not-accessible | current | An entry into the DC power system controller rectifier input group |
| 1.3.6.1.4.1.7309.4.1.6.3.2.1.1 | ColumndcPwrSysRectIpIndex | read-only | current | The index of the rectifier input variable in the DC power system controller table rectifier input group |
| 1.3.6.1.4.1.7309.4.1.6.3.2.1.2 | ColumndcPwrSysRectIpName | read-only | current | The description of the rectifier input variable as reported by the DC power system controller rectifier input group |
| 1.3.6.1.4.1.7309.4.1.6.3.2.1.3 | ColumndcPwrSysRectIpIntegerValue | read-only | current | The integer value of the rectifier input variable as reported by the DC power system controller rectifier input group |
| 1.3.6.1.4.1.7309.4.1.6.3.2.1.4 | ColumndcPwrSysRectIpStringValue | read-only | current | The string value of the rectifier input variable as reported by the DC power system controller rectifier input group |
| 1.3.6.1.4.1.7309.4.1.6.4 | NodedcPwrSysCustomIpTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.4.1 | ScalardcPwrSysCustomIpCount | read-only | current | Number of custom input variables in system controller custom input table |
| 1.3.6.1.4.1.7309.4.1.6.4.2 | TabledcPwrSysCustomIpTable | not-accessible | current | A table of DC power system controller digital custom variables |
| 1.3.6.1.4.1.7309.4.1.6.4.2.1 | RowdcPwrSysCustomIpEntry | not-accessible | current | An entry into the DC power system controller custom input group |
| 1.3.6.1.4.1.7309.4.1.6.4.2.1.1 | ColumndcPwrSysCustomIpIndex | read-only | current | The index of the custom input variable in the DC power system controller table custom input group |
| 1.3.6.1.4.1.7309.4.1.6.4.2.1.2 | ColumndcPwrSysCustomIpName | read-only | current | The description of the custom input variable as reported by the DC power system controller custom input group |
| 1.3.6.1.4.1.7309.4.1.6.4.2.1.3 | ColumndcPwrSysgCustomIpIntegerValue | read-only | current | The integer value of the custom input variable as reported by the DC power system controller custom input group |
| 1.3.6.1.4.1.7309.4.1.6.4.2.1.4 | ColumndcPwrSysCustomIpStringValue | read-only | current | The string value of the custom input variable as reported by the DC power system controller custom input group |
| 1.3.6.1.4.1.7309.4.1.6.5 | NodedcPwrSysConvIpTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.5.1 | ScalardcPwrSysConvIpCount | read-only | current | Number of Converter input variables in system controller Converter input table |
| 1.3.6.1.4.1.7309.4.1.6.5.2 | TabledcPwrSysConvIpTable | not-accessible | current | A table of DC power system controller Converter input variables |
| 1.3.6.1.4.1.7309.4.1.6.5.2.1 | RowdcPwrSysConvIpEntry | not-accessible | current | An entry into the DC power system controller Converter input group |
| 1.3.6.1.4.1.7309.4.1.6.5.2.1.1 | ColumndcPwrSysConvIpIndex | read-only | current | The index of the Converter input variable in the DC power system controller table Converter input group |
| 1.3.6.1.4.1.7309.4.1.6.5.2.1.2 | ColumndcPwrSysConvIpName | read-only | current | The description of the Converter input variable as reported by the DC power system controller Converter input group |
| 1.3.6.1.4.1.7309.4.1.6.5.2.1.3 | ColumndcPwrSysConvIpIntegerValue | read-only | current | The integer value of the Converter input variable as reported by the DC power system controller Converter input group |
| 1.3.6.1.4.1.7309.4.1.6.5.2.1.4 | ColumndcPwrSysConvIpStringValue | read-only | current | The string value of the Converter input variable as reported by the DC power system controller Converter input group |
| 1.3.6.1.4.1.7309.4.1.6.6 | NodedcPwrSysTimerIpTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.6.1 | ScalardcPwrSysTimerIpCount | read-only | current | Number of Timererter input variables in system controller Timererter input table |
| 1.3.6.1.4.1.7309.4.1.6.6.2 | TabledcPwrSysTimerIpTable | not-accessible | current | A table of DC power system controller Timererter input variables |
| 1.3.6.1.4.1.7309.4.1.6.6.2.1 | RowdcPwrSysTimerIpEntry | not-accessible | current | An entry into the DC power system controller Timererter input group |
| 1.3.6.1.4.1.7309.4.1.6.6.2.1.1 | ColumndcPwrSysTimerIpIndex | read-only | current | The index of the Timererter input variable in the DC power system controller table Timererter input group |
| 1.3.6.1.4.1.7309.4.1.6.6.2.1.2 | ColumndcPwrSysTimerIpName | read-only | current | The description of the Timererter input variable as reported by the DC power system controller Timererter input group |
| 1.3.6.1.4.1.7309.4.1.6.6.2.1.3 | ColumndcPwrSysTimerIpIntegerValue | read-only | current | The integer value of the Timererter input variable as reported by the DC power system controller Timererter input group |
| 1.3.6.1.4.1.7309.4.1.6.6.2.1.4 | ColumndcPwrSysTimerIpStringValue | read-only | current | The string value of the Timererter input variable as reported by the DC power system controller Timererter input group |
| 1.3.6.1.4.1.7309.4.1.6.7 | NodedcPwrSysCounterIpTbl | |||
| 1.3.6.1.4.1.7309.4.1.6.7.1 | ScalardcPwrSysCounterIpCount | read-only | current | Number of Countererter input variables in system controller Countererter input table |
| 1.3.6.1.4.1.7309.4.1.6.7.2 | TabledcPwrSysCounterIpTable | not-accessible | current | A table of DC power system controller Countererter input variables |
| 1.3.6.1.4.1.7309.4.1.6.7.2.1 | RowdcPwrSysCounterIpEntry | not-accessible | current | An entry into the DC power system controller Countererter input group |
| 1.3.6.1.4.1.7309.4.1.6.7.2.1.1 | ColumndcPwrSysCounterIpIndex | read-only | current | The index of the Countererter input variable in the DC power system controller table Countererter input group |
| 1.3.6.1.4.1.7309.4.1.6.7.2.1.2 | ColumndcPwrSysCounterIpName | read-only | current | The description of the Countererter input variable as reported by the DC power system controller Countererter input group |
| 1.3.6.1.4.1.7309.4.1.6.7.2.1.3 | ColumndcPwrSysCounterIpIntegerValue | read-only | current | The integer value of the Countererter input variable as reported by the DC power system controller Countererter input group |
| 1.3.6.1.4.1.7309.4.1.6.7.2.1.4 | ColumndcPwrSysCounterIpStringValue | read-only | current | The string value of the Countererter input variable as reported by the DC power system controller Countererter input group |
| 1.3.6.1.4.1.7309.4.1.8 | NodedcPwrExternalControls | |||
| 1.3.6.1.4.1.7309.4.1.8.1 | ScalardcPwrSysResyncAlarms | read-write | current | Send/Resend all active alarms that were previously sent through SNMP notification. |
| 1.3.6.1.4.1.7309.4.1.9 | NodedcPwrVarbindNameReference | |||
| 1.3.6.1.4.1.7309.4.1.9.1 | ScalardcPwrSysAlarmTriggerValue | read-only | current | |
| 1.3.6.1.4.1.7309.4.1.9.2 | ScalardcPwrSysTimeStamp | read-only | current |