BACHMANN-BLUENET2-MIB

469 objects
The MIB module for representing BlueNet2 PDU SNMP agent implementation version v1.01.00.
Imported Objects
BACHMANN-SMI-MIBbachmann
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-MIBsysObjectID
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32
SNMPv2-TCDateAndTime DisplayString RowStatus TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.31770.2IdentityblueNet2MibThe MIB module for representing BlueNet2 PDU SNMP agent implementation version v1.01.00.
1.3.6.1.4.1.31770.2.0NodeblueNet2Notifications
1.3.6.1.4.1.31770.2.0.0NodeblueNet2NotificationPrefix
1.3.6.1.4.1.31770.2.0.0.1NotificationblueNet2PduStatusOkNotificationcurrentPDU status ok.
1.3.6.1.4.1.31770.2.0.0.2NotificationblueNet2PduStatusWarningNotificationcurrentPDU status warning.
1.3.6.1.4.1.31770.2.0.0.3NotificationblueNet2PduStatusAlarmNotificationcurrentPDU status alarm.
1.3.6.1.4.1.31770.2.0.0.4NotificationblueNet2SensorStatusOkNotificationcurrentSensor status ok.
1.3.6.1.4.1.31770.2.0.0.5NotificationblueNet2SensorStatusWarningNotificationcurrentSensor status warning.
1.3.6.1.4.1.31770.2.0.0.6NotificationblueNet2SensorStatusAlarmNotificationcurrentSensor status alarm.
1.3.6.1.4.1.31770.2.0.0.7NotificationblueNet2VariableStatusOkNotificationcurrentVariable status ok.
1.3.6.1.4.1.31770.2.0.0.8NotificationblueNet2VariableLowerWarningNotificationcurrentVariable status lower warning.
1.3.6.1.4.1.31770.2.0.0.9NotificationblueNet2VariableUpperWarningNotificationcurrentVariable status upper warning.
1.3.6.1.4.1.31770.2.0.0.10NotificationblueNet2VariableLowerAlarmNotificationcurrentVariable status lower alarm.
1.3.6.1.4.1.31770.2.0.0.11NotificationblueNet2VariableUpperAlarmNotificationcurrentVariable status upper alarm.
1.3.6.1.4.1.31770.2.0.0.98NotificationblueNet2ReconfigAgentNotificationcurrentAgent reconfiguration.
1.3.6.1.4.1.31770.2.0.0.99NotificationblueNet2ShutdownAgentNotificationcurrentAgent shutdown.
1.3.6.1.4.1.31770.2.1NodeblueNet2Products
1.3.6.1.4.1.31770.2.2NodeblueNet2Objects
1.3.6.1.4.1.31770.2.2.1NodeblueNet2Identification
1.3.6.1.4.1.31770.2.2.1.1ScalarblueNet2IdProductVendorread-onlycurrentBlueNet2 vendor name.
1.3.6.1.4.1.31770.2.2.1.2ScalarblueNet2IdProductNameread-onlycurrentBlueNet2 product name.
1.3.6.1.4.1.31770.2.2.1.3ScalarblueNet2IdProductURIread-onlycurrentURI of BlueNet2 PDU product.
1.3.6.1.4.1.31770.2.2.1.4ScalarblueNet2IdProductPartNrread-onlycurrentPart number of BlueNet2 PDU product.
1.3.6.1.4.1.31770.2.2.1.5ScalarblueNet2IdProductSNrread-onlycurrentUnique serial number of BlueNet2 PDU product.
1.3.6.1.4.1.31770.2.2.1.6ScalarblueNet2IdProductDateread-onlycurrentProduction date of BlueNet2 PDU product.
1.3.6.1.4.1.31770.2.2.1.7ScalarblueNet2IdProductFacilityread-onlycurrentFunctional product facility of BlueNet2 PDU product. 0 : number of phases is 3 1 : has real fuses 2 : has any RCMs 3 : has sockets 4 : sockets can be switched …
1.3.6.1.4.1.31770.2.2.1.8ScalarblueNet2IdProductCapsread-onlycurrentCapabilities of BlueNet2 PDU product as referred in BACHMANN-BLUENET2-CAPABILITY-MIB blueNet2Capabilities. e.g. read 10203 as 01 02 03 to get version 1.2.3.
1.3.6.1.4.1.31770.2.2.1.9ScalarblueNet2IdProductFwVread-onlycurrentHardware revision of BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.1.10ScalarblueNet2IdProductHwVread-onlycurrentHardware revision of BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.1.11ScalarblueNet2IdProductSwVread-onlycurrentSoftware revision of BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.1.12ScalarblueNet2IdProductOsVread-onlycurrentOperating system revision of BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.1.13ScalarblueNet2IdProductArchread-onlycurrentOperating system cpu architecture of BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.1.14ScalarblueNet2IdProductMACread-onlycurrentEthernet MAC address of BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.2NodeblueNet2Information
1.3.6.1.4.1.31770.2.2.2.1ScalarblueNet2InfoUpTimeread-onlycurrentUptime of the BlueNet2 PDU operating system in seconds. This is different to the sysUpTime since agent (re-)start.
1.3.6.1.4.1.31770.2.2.2.2ScalarblueNet2InfoOverallStatusread-onlycurrentGeneral hadware status of BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.2.3ScalarblueNet2InfoNumberOfChangesread-onlycurrentThe number of global configuration changes.
1.3.6.1.4.1.31770.2.2.2.4ScalarblueNet2InfoLastChangeread-onlycurrentThe value of the sysUpTime object at which the last change in global configuration happened.
1.3.6.1.4.1.31770.2.2.2.5ScalarblueNet2InfoAccumulatedStatusread-onlycurrentA bit field of all current states.
1.3.6.1.4.1.31770.2.2.2.6TableblueNet2InfoLoadTablenot-accessiblecurrentA list of system load entries.
1.3.6.1.4.1.31770.2.2.2.6.1RowblueNet2InfoLoadEntrynot-accessiblecurrentEntries of system load table.
1.3.6.1.4.1.31770.2.2.2.6.1.1ColumnblueNet2InfoLoadIndexnot-accessiblecurrentIndex for the system load table. These are the past minutes the load is given for.
1.3.6.1.4.1.31770.2.2.2.6.1.2ColumnblueNet2InfoLoadAverageread-onlycurrentSystem load average multiplied by 100.
1.3.6.1.4.1.31770.2.2.2.7TableblueNet2InfoMessageTablenot-accessiblecurrentA table of the last text message per source.
1.3.6.1.4.1.31770.2.2.2.7.1RowblueNet2InfoMessageEntrynot-accessiblecurrentEntries of last message table.
1.3.6.1.4.1.31770.2.2.2.7.1.1ColumnblueNet2InfoMessageSourcenot-accessiblecurrentSource of the text message.
1.3.6.1.4.1.31770.2.2.2.7.1.2ColumnblueNet2InfoMessageStatusread-onlycurrentStatus of the text message source.
1.3.6.1.4.1.31770.2.2.2.7.1.3ColumnblueNet2InfoMessageTimeread-onlycurrentTimestamp of last received text message according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.2.7.1.4ColumnblueNet2InfoMessageTextread-onlycurrentLast text message of a source.
1.3.6.1.4.1.31770.2.2.2.7.1.5ColumnblueNet2InfoMessageNumberOfOksread-onlycurrentThe accumulated number of ok messages.
1.3.6.1.4.1.31770.2.2.2.7.1.6ColumnblueNet2InfoMessageNumberOfWarningsread-onlycurrentThe accumulated number of warning messages.
1.3.6.1.4.1.31770.2.2.2.7.1.7ColumnblueNet2InfoMessageNumberOfErrorsread-onlycurrentThe accumulated number of error messages.
1.3.6.1.4.1.31770.2.2.3NodeblueNet2Configuration
1.3.6.1.4.1.31770.2.2.3.1ScalarblueNet2Aliasread-writecurrentBlueNet2 product alias. This object should be set by the administrator.
1.3.6.1.4.1.31770.2.2.3.2ScalarblueNet2Languageread-writedeprecatedSupported display language.
1.3.6.1.4.1.31770.2.2.3.3ScalarblueNet2DateTimeread-writecurrentDate and time of day as set manually or by NTP.
1.3.6.1.4.1.31770.2.2.3.4NodeblueNet2Protocols
1.3.6.1.4.1.31770.2.2.3.4.1ScalarblueNet2FtpAccessread-writecurrentFtp access status.
1.3.6.1.4.1.31770.2.2.3.4.2ScalarblueNet2FtpPortread-writecurrentTCP/IP port of FTP daemon.
1.3.6.1.4.1.31770.2.2.3.4.3ScalarblueNet2HttpAccessread-writecurrentHTTP/HTTPS access status.
1.3.6.1.4.1.31770.2.2.3.4.4ScalarblueNet2HttpPortread-writecurrentTCP/IP port of HTTP daemon.
1.3.6.1.4.1.31770.2.2.3.4.5ScalarblueNet2HttpsPortread-writecurrentTCP/IP port of HTTPS daemon.
1.3.6.1.4.1.31770.2.2.3.4.6ScalarblueNet2SftpAccessread-writedeprecatedSftp access status.
1.3.6.1.4.1.31770.2.2.3.4.7ScalarblueNet2SftpPortread-writedeprecatedTCP/IP port of SFTP daemon.
1.3.6.1.4.1.31770.2.2.3.4.8ScalarblueNet2SshAccessread-writecurrentSsh access status.
1.3.6.1.4.1.31770.2.2.3.4.9ScalarblueNet2SshPortread-writecurrentTCP/IP port of SSH daemon.
1.3.6.1.4.1.31770.2.2.3.4.10ScalarblueNet2TelnetAccessread-writedeprecatedTelnet access status.
1.3.6.1.4.1.31770.2.2.3.4.11ScalarblueNet2TelnetPortread-writedeprecatedTCP/IP port of telnet daemon.
1.3.6.1.4.1.31770.2.2.3.4.12NodeblueNet2Snmp
1.3.6.1.4.1.31770.2.2.3.4.12.1ScalarblueNet2SnmpVersionsread-onlycurrentSupported and enabled SNMP versions.
1.3.6.1.4.1.31770.2.2.3.4.12.2ScalarblueNet2MaxTrapReceiversread-onlycurrentThe maximum number of entries in blueNet2TrapReceiverTable.
1.3.6.1.4.1.31770.2.2.3.4.12.3TableblueNet2TrapReceiverTablenot-accessiblecurrentA list of trap receiver entries.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1RowblueNet2TrapReceiverEntrynot-accessiblecurrentEntries of trapTable.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.1ColumnblueNet2TrapReceiverIndexnot-accessiblecurrentIndex of the trap receiver table.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.2ColumnblueNet2TrapReceiverRowStatusread-createcurrentActivate/create/destroy/disable a trap receiver entry.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.3ColumnblueNet2TrapReceiverProtocolread-onlycurrentSet trap/inform version.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.4ColumnblueNet2TrapReceiverAddressread-onlycurrentIPv4/IPv6 address or host name of trap receiver.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.5ColumnblueNet2TrapReceiverFriendlyNameread-onlydeprecatedUser friendly name to identify a trap receiver. This is a mnemonic only and will not be used to send traps.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.6ColumnblueNet2TrapReceiverDescriptionread-onlydeprecatedDescription to identify a trap receiver. This is a mnemonic only and will not be used to send traps.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.7ColumnblueNet2TrapReceiverCommunityread-onlycurrentCommunity used by SNMPv1 and SNMPv2c to identify at trap receiver address.
1.3.6.1.4.1.31770.2.2.3.4.12.3.1.8ColumnblueNet2TrapReceiverUsernameread-onlycurrentUsername used by SNMPv3 to identify at trap receiver address.
1.3.6.1.4.1.31770.2.2.3.4.13NodeblueNet2Modbus
1.3.6.1.4.1.31770.2.2.3.4.13.1ScalarblueNet2ModbusVersionsread-writecurrentSupported and enabled modbus version(s).
1.3.6.1.4.1.31770.2.2.3.4.13.2ScalarblueNet2ModbusServiceread-writedeprecatedModbus service status.
1.3.6.1.4.1.31770.2.2.3.4.13.3ScalarblueNet2ModbusTcpPortread-writecurrentTCP/IP port of modbus daemon.
1.3.6.1.4.1.31770.2.2.3.4.13.4ScalarblueNet2ModbusSerialModeread-writedeprecatedSerial mode configuration parameters (baud,data,parity,stop) of modbus daemon.
1.3.6.1.4.1.31770.2.2.3.4.13.5ScalarblueNet2MaxModbusTcpMastersread-onlycurrentThe maximum number of entries in blueNet2ModbusTcpTable.
1.3.6.1.4.1.31770.2.2.3.4.13.6TableblueNet2ModbusTcpTablenot-accessibledeprecatedA list of modbus entries.
1.3.6.1.4.1.31770.2.2.3.4.13.6.1RowblueNet2ModbusTcpEntrynot-accessibledeprecatedEntries of modbus table.
1.3.6.1.4.1.31770.2.2.3.4.13.6.1.1ColumnblueNet2ModbusTcpIndexnot-accessibledeprecatedIndex of the modbus TCP access table.
1.3.6.1.4.1.31770.2.2.3.4.13.6.1.2ColumnblueNet2ModbusTcpRowStatusread-createdeprecatedActivate/create/destroy/disable a modbus TCP entry.
1.3.6.1.4.1.31770.2.2.3.4.13.6.1.3ColumnblueNet2ModbusTcpAccessread-writedeprecatedModbus access for this master entry. This access is inferior to blueNet2ModbusService, e.g. readwrite access also requires readwrite status.
1.3.6.1.4.1.31770.2.2.3.4.13.6.1.4ColumnblueNet2ModbusTcpMasterread-writedeprecatedSource to restrict modbus access. It can either be a specific hostname, IP address, or a subnet represented as IP/MASK (e.g. 10.10.10.0/255.255.255.0), or IP/B…
1.3.6.1.4.1.31770.2.2.3.4.13.6.1.5ColumnblueNet2ModbusTcpFriendlyNameread-writedeprecatedUser friendly name to identify a modbus master. This is a mnemonic only and will not be used to query data.
1.3.6.1.4.1.31770.2.2.3.4.13.6.1.6ColumnblueNet2ModbusTcpDescriptionread-writedeprecatedDescription to identify a modbus master. This is a mnemonic only and will not be used to query data.
1.3.6.1.4.1.31770.2.2.3.4.14NodeblueNet2Ntp
1.3.6.1.4.1.31770.2.2.3.4.14.1ScalarblueNet2NtpServiceread-writecurrentNTP service status.
1.3.6.1.4.1.31770.2.2.3.4.14.2ScalarblueNet2NtpPortread-writecurrentTCP/IP port of NTP server.
1.3.6.1.4.1.31770.2.2.3.4.14.3ScalarblueNet2NtpTimeZoneread-writecurrentTime Zone, list is sorted once by time offset and once by index 24 : (GMT-12:00) International Date Line West 99 : (GMT-11:00) Coordinated Universal Time-11 39…
1.3.6.1.4.1.31770.2.2.3.4.14.4ScalarblueNet2MaxNtpServersread-onlycurrentThe maximum number of entries in blueNet2NtpServerTable.
1.3.6.1.4.1.31770.2.2.3.4.14.5TableblueNet2NtpServerTablenot-accessiblecurrentA list of NTP server entries.
1.3.6.1.4.1.31770.2.2.3.4.14.5.1RowblueNet2NtpServerEntrynot-accessiblecurrentEntries of NTP server table.
1.3.6.1.4.1.31770.2.2.3.4.14.5.1.1ColumnblueNet2NtpServerIndexnot-accessiblecurrentIndex of the NTP server table.
1.3.6.1.4.1.31770.2.2.3.4.14.5.1.2ColumnblueNet2NtpServerRowStatusread-createcurrentActivate/create/destroy/disable a NTP server entry.
1.3.6.1.4.1.31770.2.2.3.4.14.5.1.3ColumnblueNet2NtpServerAddressread-writecurrentIP address or name of NTP server.
1.3.6.1.4.1.31770.2.2.3.4.14.5.1.4ColumnblueNet2NtpServerFriendlyNameread-onlydeprecatedUser friendly name to identify a ntp server. This is a mnemonic only and will not be used to query data.
1.3.6.1.4.1.31770.2.2.3.4.14.5.1.5ColumnblueNet2NtpServerDescriptionread-onlydeprecatedDescription to identify a ntp server. This is a mnemonic only and will not be used to query data.
1.3.6.1.4.1.31770.2.2.3.4.15NodeblueNet2Smtp
1.3.6.1.4.1.31770.2.2.3.4.15.1ScalarblueNet2SmtpServiceread-writecurrentSMTP service status.
1.3.6.1.4.1.31770.2.2.3.4.15.2ScalarblueNet2SmtpPortread-writecurrentTCP/IP port of SMTP server.
1.3.6.1.4.1.31770.2.2.3.4.15.3ScalarblueNet2SmtpServerread-writecurrentIP address or name of SMTP server.
1.3.6.1.4.1.31770.2.2.3.4.15.4ScalarblueNet2SmtpAuthread-writecurrentSMTP authentication mode.
1.3.6.1.4.1.31770.2.2.3.4.15.5ScalarblueNet2SmtpUsernameread-writecurrentUsername required to authenticate at the SMTP server.
1.3.6.1.4.1.31770.2.2.3.4.15.6ScalarblueNet2SmtpPasswordread-writecurrentPassword required to authenticate at the SMTP server.
1.3.6.1.4.1.31770.2.2.3.4.15.7ScalarblueNet2SmtpFromread-writecurrentSender address of the SMTP message.
1.3.6.1.4.1.31770.2.2.3.4.15.8ScalarblueNet2SmtpReplyread-writecurrentReply address of the SMTP message.
1.3.6.1.4.1.31770.2.2.3.4.15.9ScalarblueNet2MaxSmtpReceiversread-onlycurrentThe maximum number of entries in blueNet2SmtpReceiverTable.
1.3.6.1.4.1.31770.2.2.3.4.15.10TableblueNet2SmtpReceiverTablenot-accessibledeprecatedA list of SMTP receiver entries.
1.3.6.1.4.1.31770.2.2.3.4.15.10.1RowblueNet2SmtpReceiverEntrynot-accessibledeprecatedEntries of SMTP receiver table.
1.3.6.1.4.1.31770.2.2.3.4.15.10.1.1ColumnblueNet2SmtpReceiverIndexnot-accessibledeprecatedIndex of the SMTP receiver table.
1.3.6.1.4.1.31770.2.2.3.4.15.10.1.2ColumnblueNet2SmtpReceiverRowStatusread-createdeprecatedActivate/create/destroy/disable a SMTP receiver entry.
1.3.6.1.4.1.31770.2.2.3.4.15.10.1.3ColumnblueNet2SmtpReceiverAddressread-writedeprecatedIP address or name of SMTP receiver.
1.3.6.1.4.1.31770.2.2.3.4.15.10.1.4ColumnblueNet2SmtpReceiverFriendlyNameread-writedeprecatedUser friendly name to identify a smtp server. This is a mnemonic only and will not be used to send data.
1.3.6.1.4.1.31770.2.2.3.4.15.10.1.5ColumnblueNet2SmtpReceiverDescriptionread-writedeprecatedDescription to identify a smtp server. This is a mnemonic only and will not be used to send data.
1.3.6.1.4.1.31770.2.2.3.4.16NodeblueNet2Syslog
1.3.6.1.4.1.31770.2.2.3.4.16.1ScalarblueNet2SyslogServiceread-writecurrentSyslog service status.
1.3.6.1.4.1.31770.2.2.3.4.16.2ScalarblueNet2SyslogFacilityread-writecurrentSyslog facility local0 .. local7.
1.3.6.1.4.1.31770.2.2.3.4.16.3ScalarblueNet2MaxSyslogServersread-onlycurrentThe maximum number of entries in blueNet2SyslogServerTable.
1.3.6.1.4.1.31770.2.2.3.4.16.4TableblueNet2SyslogServerTablenot-accessiblecurrentA list of syslog server entries.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1RowblueNet2SyslogServerEntrynot-accessiblecurrentEntries of syslog server table.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1.1ColumnblueNet2SyslogServerIndexnot-accessiblecurrentIndex of the syslog server table.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1.2ColumnblueNet2SyslogServerRowStatusread-createcurrentActivate/create/destroy/disable a syslog server entry.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1.3ColumnblueNet2SyslogServerAddressread-writecurrentIP address or name of syslog server.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1.4ColumnblueNet2SyslogServerPortread-writecurrentTCP/IP port of syslog server.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1.5ColumnblueNet2SyslogServerFriendlyNameread-onlydeprecatedUser friendly name to identify a syslog server. This is a mnemonic only and will not be used to send data.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1.6ColumnblueNet2SyslogServerDescriptionread-onlydeprecatedDescription to identify a syslog server. This is a mnemonic only and will not be used to send data.
1.3.6.1.4.1.31770.2.2.3.4.16.4.1.7ColumnblueNet2SyslogServerProtocolread-writecurrentSet TCP/IP protocol of syslog server.
1.3.6.1.4.1.31770.2.2.4NodeblueNet2Devices
1.3.6.1.4.1.31770.2.2.4.1NodeblueNet2DeviceInfo
1.3.6.1.4.1.31770.2.2.4.1.1ScalarblueNet2OverallDeviceStatusread-onlycurrentOverall status of all devices.
1.3.6.1.4.1.31770.2.2.4.1.2ScalarblueNet2NumberOfDevicesread-onlycurrentNumber of devices available.
1.3.6.1.4.1.31770.2.2.4.1.3ScalarblueNet2LastChangeOverallDeviceStatusread-onlycurrentTimestamp of last status change of any device connected to BlueNet2 PDU according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.4.1.4ScalarblueNet2LastChangeNumberOfDevicesread-onlycurrentTimestamp of last device number change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.4.1.5ScalarblueNet2LastChangeDeviceSettingsread-onlycurrentTimestamp of last setting change of any device connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP setting…
1.3.6.1.4.1.31770.2.2.4.1.6ScalarblueNet2LastChangeDevicesread-onlycurrentTimestamp of last device change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.4.1.7ScalarblueNet2DevicesAccumulatedStatusread-onlycurrentA bit field of all current device states.
1.3.6.1.4.1.31770.2.2.4.2TableblueNet2DeviceTablenot-accessiblecurrentHeadline of device table.
1.3.6.1.4.1.31770.2.2.4.2.1RowblueNet2DeviceEntrynot-accessiblecurrentEntries of device table.
1.3.6.1.4.1.31770.2.2.4.2.1.1ColumnblueNet2DeviceIndexnot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.2ColumnblueNet2DeviceGuidread-onlycurrentGUID of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.3ColumnblueNet2DeviceNameread-onlycurrentName of the device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.4ColumnblueNet2DeviceFriendlyNameread-writecurrentUser friendlyname of the device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.5ColumnblueNet2DeviceDescriptionread-writecurrentDescription of the device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.6ColumnblueNet2DeviceTyperead-onlycurrentType of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.7ColumnblueNet2DeviceStatusread-onlycurrentGeneral status of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.8ColumnblueNet2DeviceAlarmread-onlydeprecatedAlarm text of device connected to BlueNet2 PDU. This field is deprecated and is not filled.
1.3.6.1.4.1.31770.2.2.4.2.1.9ColumnblueNet2DeviceLastChangeread-onlycurrentTimestamp of last change of device connected to BlueNet2 PDU according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.4.2.1.10ColumnblueNet2DeviceEntPhysicalIndexread-onlycurrentCorresponding entPhysicalIndex of this device. 0 if none exists.
1.3.6.1.4.1.31770.2.2.4.2.1.11ColumnblueNet2DevicePartNrread-onlycurrentArticle part number of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.12ColumnblueNet2DeviceSNrread-onlycurrentSerial number of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.13ColumnblueNet2DeviceFwVread-onlycurrentFirmware version of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.14ColumnblueNet2DeviceHwVread-onlycurrentHardware version of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.15ColumnblueNet2DeviceSwVread-onlycurrentSoftware version of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.16ColumnblueNet2DeviceOsVread-onlycurrentOperating system version of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.17ColumnblueNet2DeviceMACread-onlycurrentMAC address of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.18ColumnblueNet2DeviceNumberOfSensorsread-onlycurrentNumber of sensors available on this device. This variable will give the number of rows of the sensor table blueNet2SensorTable belonging to this device.
1.3.6.1.4.1.31770.2.2.4.2.1.19ColumnblueNet2DeviceNumberOfCircuitsread-onlycurrentNumber of circuits available in this device. This variable will give the number of rows of the circuit table blueNet2CircuitTable belonging to this device.
1.3.6.1.4.1.31770.2.2.4.2.1.20ColumnblueNet2DeviceNumberOfPhasesread-onlycurrentNumber of phases available in this device. This variable will give the number of rows of the phases table blueNet2PhaseTable belonging to this device.
1.3.6.1.4.1.31770.2.2.4.2.1.21ColumnblueNet2DeviceNumberOfFusesread-onlycurrentNumber of fuses available in this device. This variable will give the number of rows of the fuse table blueNet2FuseTable belonging to this device.
1.3.6.1.4.1.31770.2.2.4.2.1.22ColumnblueNet2DeviceNumberOfSocketsread-onlycurrentNumber of sockets available in this device. This variable will give the number of rows of the socket table blueNet2SocketTable belonging to this device.
1.3.6.1.4.1.31770.2.2.4.2.1.23ColumnblueNet2DeviceNumberOfRCMsread-onlycurrentNumber of RCMs available in this device. This variable will give the number of rows of the RCM table blueNet2RcmTable belonging to this device.
1.3.6.1.4.1.31770.2.2.4.2.1.24ColumnblueNet2DeviceNumberOfVarsread-onlycurrentNumber of variables available in this device. This variable will give the number of rows of the variable table blueNet2VariableTable belonging to this device.
1.3.6.1.4.1.31770.2.2.4.2.1.25ColumnblueNet2DeviceLocationread-writecurrentLocation of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.4.2.1.26ColumnblueNet2DeviceProductDateread-onlycurrentDevice Production Date.
1.3.6.1.4.1.31770.2.2.4.2.1.27ColumnblueNet2DeviceModbusAddrread-onlycurrentDevice Modbus Address.
1.3.6.1.4.1.31770.2.2.4.2.1.28ColumnblueNet2DeviceNumberOfSPDsread-onlycurrentNumber of SPDs available in this device. This variable will give the number of rows of the SPD table blueNet2SpdTable belonging to this device.
1.3.6.1.4.1.31770.2.2.5NodeblueNet2Sensors
1.3.6.1.4.1.31770.2.2.5.1NodeblueNet2SensorInfo
1.3.6.1.4.1.31770.2.2.5.1.1ScalarblueNet2OverallSensorStatusread-onlycurrentOverall status of all sensors.
1.3.6.1.4.1.31770.2.2.5.1.2ScalarblueNet2NumberOfSensorsread-onlycurrentNumber of sensors available.
1.3.6.1.4.1.31770.2.2.5.1.3ScalarblueNet2LastChangeOverallSensorStatusread-onlycurrentTimestamp of last status change of any sensor connected to BlueNet2 PDU according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.5.1.4ScalarblueNet2LastChangeNumberOfSensorsread-onlycurrentTimestamp of last sensor number change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.5.1.5ScalarblueNet2LastChangeSensorSettingsread-onlycurrentTimestamp of last setting change of any sensor connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP setting…
1.3.6.1.4.1.31770.2.2.5.1.6ScalarblueNet2LastChangeSensorsread-onlycurrentTimestamp of last sensor change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.5.1.7ScalarblueNet2SensorsAccumulatedStatusread-onlycurrentA bit field of all current sensor states.
1.3.6.1.4.1.31770.2.2.5.2TableblueNet2SensorTablenot-accessiblecurrentHeadline of sensor table.
1.3.6.1.4.1.31770.2.2.5.2.1RowblueNet2SensorEntrynot-accessiblecurrentEntries of sensor table.
1.3.6.1.4.1.31770.2.2.5.2.1.1ColumnblueNet2SensorDevicenot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.2ColumnblueNet2SensorIndexnot-accessiblecurrentIndex of sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.3ColumnblueNet2SensorGuidread-onlycurrentGUID of sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.4ColumnblueNet2SensorNameread-onlycurrentName of the sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.5ColumnblueNet2SensorFriendlyNameread-writecurrentUser friendlyname of the sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.6ColumnblueNet2SensorDescriptionread-writecurrentDescription of the sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.7ColumnblueNet2SensorTyperead-onlycurrentType of of sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.8ColumnblueNet2SensorStatusread-onlycurrentGeneral Status of sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.9ColumnblueNet2SensorAlarmread-onlycurrentAlarm text of sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.2.1.10ColumnblueNet2SensorLastChangeread-onlycurrentTimestamp of last change of sensor connected to BlueNet2 PDU according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.5.2.1.11ColumnblueNet2SensorEntPhysicalIndexread-onlycurrentCorresponding entPhysicalIndex of this sensor. 0 if none exists.
1.3.6.1.4.1.31770.2.2.5.2.1.12ColumnblueNet2SensorNumberOfVarsread-onlycurrentNumber of variables available on this sensor. This variable will give the number of rows of the variable table blueNet2SensorVarTable belonging to this sensor.
1.3.6.1.4.1.31770.2.2.5.2.1.13ColumnblueNet2SensorHwVread-onlycurrentHardware version of the sensor.
1.3.6.1.4.1.31770.2.2.5.2.1.14ColumnblueNet2SensorFwVread-onlycurrentFirmware version of the sensor.
1.3.6.1.4.1.31770.2.2.5.2.1.15ColumnblueNet2SensorSNrread-onlycurrentSerial number of the sensor.
1.3.6.1.4.1.31770.2.2.5.3TableblueNet2SensorVariableTablenot-accessiblecurrentHeadline of sensor variable table.
1.3.6.1.4.1.31770.2.2.5.3.1RowblueNet2SensorVariableEntrynot-accessiblecurrentEntries of sensor variable table.
1.3.6.1.4.1.31770.2.2.5.3.1.1ColumnblueNet2SensorDeviceIndexnot-accessiblecurrentIndex of sensor connected.
1.3.6.1.4.1.31770.2.2.5.3.1.2ColumnblueNet2SensorSensorIndexnot-accessiblecurrentIndex of sensor connected.
1.3.6.1.4.1.31770.2.2.5.3.1.3ColumnblueNet2SensorVariableIndexnot-accessiblecurrentIndex of sensor variable.
1.3.6.1.4.1.31770.2.2.5.3.1.4ColumnblueNet2SensorVariableGuidread-onlycurrentGUID of sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.3.1.5ColumnblueNet2SensorVariableNameread-onlycurrentName of the sensor variable.
1.3.6.1.4.1.31770.2.2.5.3.1.6ColumnblueNet2SensorVariableFriendlyNameread-onlycurrentUser friendlyname of the sensor variable.
1.3.6.1.4.1.31770.2.2.5.3.1.7ColumnblueNet2SensorVariableDescriptionread-onlycurrentDescription of the sensor variable.
1.3.6.1.4.1.31770.2.2.5.3.1.8ColumnblueNet2SensorVariableGPIOModeread-writecurrentMode of the GPIO sensor connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.5.3.1.9ColumnblueNet2SensorVariableGPIOSwitchread-writecurrentSwitch on/off the GPIO Outputs.
1.3.6.1.4.1.31770.2.2.5.3.1.10ColumnblueNet2SensorVariableGPIOStateread-onlycurrentState of GPIO inputs/outputs
1.3.6.1.4.1.31770.2.2.6NodeblueNet2Circuits
1.3.6.1.4.1.31770.2.2.6.1NodeblueNet2CircuitInfo
1.3.6.1.4.1.31770.2.2.6.1.1ScalarblueNet2OverallCircuitStatusread-onlycurrentOverall status of all circuits.
1.3.6.1.4.1.31770.2.2.6.1.2ScalarblueNet2NumberOfCircuitsread-onlycurrentNumber of circuits available.
1.3.6.1.4.1.31770.2.2.6.1.3ScalarblueNet2LastChangeOverallCircuitStatusread-onlycurrentTimestamp of last status change of any circuit connected to BlueNet2 PDU according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.6.1.4ScalarblueNet2LastChangeNumberOfCircuitsread-onlycurrentTimestamp of last circuit number change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.6.1.5ScalarblueNet2LastChangeCircuitSettingsread-onlycurrentTimestamp of last setting change of any circuit connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP settin…
1.3.6.1.4.1.31770.2.2.6.1.6ScalarblueNet2LastChangeCircuitsread-onlycurrentTimestamp of last circuit change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.6.2TableblueNet2CircuitTablenot-accessiblecurrentHeadline of circuit table.
1.3.6.1.4.1.31770.2.2.6.2.1RowblueNet2CircuitEntrynot-accessiblecurrentEntries of circuit table.
1.3.6.1.4.1.31770.2.2.6.2.1.1ColumnblueNet2CircuitDevicenot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.2.1.2ColumnblueNet2CircuitIndexnot-accessiblecurrentIndex of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.2.1.3ColumnblueNet2CircuitGuidread-onlycurrentGUID of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.2.1.4ColumnblueNet2CircuitNameread-onlycurrentName of the circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.2.1.5ColumnblueNet2CircuitFriendlyNameread-writecurrentUser friendlyname of the circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.2.1.6ColumnblueNet2CircuitDescriptionread-writecurrentDescription of the circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.2.1.7ColumnblueNet2CircuitTyperead-onlycurrentType of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.2.1.8ColumnblueNet2CircuitStatusread-onlycurrentGeneral status of the entity providing the status of a circuit connected to BlueNet2 PDU in blueNet2VariableStatus.
1.3.6.1.4.1.31770.2.2.6.2.1.9ColumnblueNet2CircuitNumberOfPhasesread-onlycurrentNumber of phases of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3TableblueNet2PhaseTablenot-accessiblecurrentHeadline of phase table.
1.3.6.1.4.1.31770.2.2.6.3.1RowblueNet2PhaseEntrynot-accessiblecurrentEntries of phase table.
1.3.6.1.4.1.31770.2.2.6.3.1.1ColumnblueNet2PhaseDevicenot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3.1.2ColumnblueNet2PhaseCircuitnot-accessiblecurrentIndex of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3.1.3ColumnblueNet2PhaseIndexnot-accessiblecurrentIndex of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3.1.4ColumnblueNet2PhaseGuidread-onlycurrentGUID of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3.1.5ColumnblueNet2PhaseNameread-onlycurrentName of the phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3.1.6ColumnblueNet2PhaseFriendlyNameread-writecurrentUser friendlyname of the phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3.1.7ColumnblueNet2PhaseDescriptionread-writecurrentDescription of the phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.3.1.8ColumnblueNet2PhaseStatusread-onlycurrentGeneral status of the entity providing the status of a phase connected to BlueNet2 PDU in blueNet2VariableStatus.
1.3.6.1.4.1.31770.2.2.6.3.1.9ColumnblueNet2PhaseNumberOfFusesread-onlycurrentNumber of fuses of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4TableblueNet2FuseTablenot-accessiblecurrentHeadline of fuse table.
1.3.6.1.4.1.31770.2.2.6.4.1RowblueNet2FuseEntrynot-accessiblecurrentEntries of fuse table.
1.3.6.1.4.1.31770.2.2.6.4.1.1ColumnblueNet2FuseDevicenot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.2ColumnblueNet2FuseCircuitnot-accessiblecurrentIndex of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.3ColumnblueNet2FusePhasenot-accessiblecurrentIndex of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.4ColumnblueNet2FuseIndexnot-accessiblecurrentIndex of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.5ColumnblueNet2FuseGuidread-onlycurrentGUID of fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.6ColumnblueNet2FuseNameread-onlycurrentName of the fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.7ColumnblueNet2FuseFriendlyNameread-writecurrentUser friendlyname of the fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.8ColumnblueNet2FuseDescriptionread-writecurrentDescription of the fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.9ColumnblueNet2FuseTyperead-onlycurrentType of the fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.4.1.10ColumnblueNet2FuseStatusread-onlycurrentGeneral status of the entity providing the status of a fuse connected to BlueNet2 PDU in blueNet2VariableStatus.
1.3.6.1.4.1.31770.2.2.6.4.1.11ColumnblueNet2FuseNumberOfSocketsread-onlycurrentNumber of sockets of fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5TableblueNet2SocketTablenot-accessiblecurrentHeadline of socket table.
1.3.6.1.4.1.31770.2.2.6.5.1RowblueNet2SocketEntrynot-accessiblecurrentEntries of socket table.
1.3.6.1.4.1.31770.2.2.6.5.1.1ColumnblueNet2SocketDevicenot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.2ColumnblueNet2SocketCircuitnot-accessiblecurrentIndex of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.3ColumnblueNet2SocketPhasenot-accessiblecurrentIndex of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.4ColumnblueNet2SocketFusenot-accessiblecurrentIndex of fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.5ColumnblueNet2SocketIndexnot-accessiblecurrentIndex of socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.6ColumnblueNet2SocketGuidread-onlycurrentGUID of socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.7ColumnblueNet2SocketNameread-onlycurrentName of the socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.8ColumnblueNet2SocketFriendlyNameread-writecurrentUser friendlyname of the socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.9ColumnblueNet2SocketDescriptionread-writecurrentDescription of the socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.10ColumnblueNet2SocketTyperead-onlycurrentType of the socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.11ColumnblueNet2SocketStatusread-onlycurrentGeneral status of the entity providing the status of a socket connected to BlueNet2 PDU in blueNet2VariableStatus.
1.3.6.1.4.1.31770.2.2.6.5.1.12ColumnblueNet2SocketModeread-writecurrentMode of the socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.13ColumnblueNet2SocketIdentifyread-writecurrentMode of the sockets LED connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.5.1.14ColumnblueNet2SocketMemberIndexread-onlycurrentIndex of this socket to be used in blueNet2SocketGroupMembers.
1.3.6.1.4.1.31770.2.2.6.6TableblueNet2RcmTablenot-accessiblecurrentHeadline of rcm table.
1.3.6.1.4.1.31770.2.2.6.6.1RowblueNet2RcmEntrynot-accessiblecurrentEntries of rcm table.
1.3.6.1.4.1.31770.2.2.6.6.1.1ColumnblueNet2RcmDevicenot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.2ColumnblueNet2RcmCircuitnot-accessiblecurrentIndex of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.3ColumnblueNet2RcmPhasenot-accessiblecurrentIndex of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.4ColumnblueNet2RcmFusenot-accessiblecurrentIndex of fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.5ColumnblueNet2RcmSocketnot-accessiblecurrentIndex of socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.6ColumnblueNet2RcmIndexnot-accessiblecurrentIndex of RCM connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.7ColumnblueNet2RcmGuidread-onlycurrentGUID of RCM connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.8ColumnblueNet2RcmNameread-onlycurrentName of the RCM connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.9ColumnblueNet2RcmFriendlyNameread-writecurrentUser friendlyname of the RCM connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.10ColumnblueNet2RcmDescriptionread-writecurrentDescription of the RCM connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.11ColumnblueNet2RcmTyperead-onlycurrentType of the rcm connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.6.1.12ColumnblueNet2RcmStatusread-onlycurrentGeneral status of the entity providing the status of a Rcm connected to BlueNet2 PDU in blueNet2VariableStatus.
1.3.6.1.4.1.31770.2.2.6.6.1.13ColumnblueNet2RcmSelftestCommandread-writecurrentRCM self-test commands.
1.3.6.1.4.1.31770.2.2.6.6.1.14ColumnblueNet2RcmSelftestResultValueread-onlycurrentRCM self-test result value.
1.3.6.1.4.1.31770.2.2.6.6.1.15ColumnblueNet2RcmSelftestResultACvalueread-onlycurrentRCM self-test AC result value.
1.3.6.1.4.1.31770.2.2.6.6.1.16ColumnblueNet2RcmSelftestResultDCvalueread-onlycurrentRCM self-test DC result value.
1.3.6.1.4.1.31770.2.2.6.6.1.17ColumnblueNet2RcmSelftestTimeStampread-onlycurrentTimestamp of RCM self-test.
1.3.6.1.4.1.31770.2.2.6.6.1.18ColumnblueNet2RcmSelftestResultStrread-onlycurrentRCM Selftest result as string.
1.3.6.1.4.1.31770.2.2.6.7TableblueNet2SpdTablenot-accessiblecurrentHeadline of SPD table.
1.3.6.1.4.1.31770.2.2.6.7.1RowblueNet2SpdEntrynot-accessiblecurrentEntries of spd table.
1.3.6.1.4.1.31770.2.2.6.7.1.1ColumnblueNet2SpdDevicenot-accessiblecurrentIndex of device connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.2ColumnblueNet2SpdCircuitnot-accessiblecurrentIndex of circuit connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.3ColumnblueNet2SpdPhasenot-accessiblecurrentIndex of phase connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.4ColumnblueNet2SpdFusenot-accessiblecurrentIndex of fuse connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.5ColumnblueNet2SpdSocketnot-accessiblecurrentIndex of socket connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.6ColumnblueNet2SpdIndexnot-accessiblecurrentIndex of SPD connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.7ColumnblueNet2SpdGuidread-onlycurrentGUID of SPD connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.8ColumnblueNet2SpdNameread-onlycurrentName of the SPD connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.9ColumnblueNet2SpdFriendlyNameread-writecurrentUser friendlyname of the SPD connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.10ColumnblueNet2SpdDescriptionread-writecurrentDescription of the SPD connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.11ColumnblueNet2SpdTyperead-onlycurrentType of the spd connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.6.7.1.12ColumnblueNet2SpdStatusread-onlycurrentGeneral status of the entity providing the status of an SPD connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7NodeblueNet2SocketGroups
1.3.6.1.4.1.31770.2.2.7.1NodeblueNet2SocketGroupInfo
1.3.6.1.4.1.31770.2.2.7.1.1ScalarblueNet2OverallSocketGroupStatusread-onlycurrentOverall status of all socket groups.
1.3.6.1.4.1.31770.2.2.7.1.2ScalarblueNet2NumberOfSocketGroupsread-onlycurrentNumber of socket groups available.
1.3.6.1.4.1.31770.2.2.7.1.3ScalarblueNet2LastChangeOverallSocketGroupStatusread-onlycurrentTimestamp of last status change of any socket group connected to BlueNet2 PDU according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.7.1.4ScalarblueNet2LastChangeNumberOfSocketGroupsread-onlycurrentTimestamp of last socket group number change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.7.1.5ScalarblueNet2LastChangeSocketGroupSettingsread-onlycurrentTimestamp of last setting change of any socket group connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP s…
1.3.6.1.4.1.31770.2.2.7.1.6ScalarblueNet2LastChangeSocketGroupsread-onlycurrentTimestamp of last socket group change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.7.1.7ScalarblueNet2SocketGroupsAccumulatedStatusread-onlycurrentA bit field of all current socket group states.
1.3.6.1.4.1.31770.2.2.7.1.8ScalarblueNet2SocketGroupsInUseread-onlycurrentNumber of socket groups in use.
1.3.6.1.4.1.31770.2.2.7.1.9ScalarblueNet2MaxSocketGroupsread-onlycurrentThe maximum number of entries in blueNet2SocketGroupTable.
1.3.6.1.4.1.31770.2.2.7.2TableblueNet2SocketGroupTablenot-accessiblecurrentHeadline of socket group table.
1.3.6.1.4.1.31770.2.2.7.2.1RowblueNet2SocketGroupEntrynot-accessiblecurrentEntries of socket group table.
1.3.6.1.4.1.31770.2.2.7.2.1.1ColumnblueNet2SocketGroupIndexnot-accessiblecurrentIndex of socket group available on BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7.2.1.2ColumnblueNet2SocketGroupRowStatusread-createcurrentActivate/create/destroy/disable a socket group entry.
1.3.6.1.4.1.31770.2.2.7.2.1.3ColumnblueNet2SocketGroupGuidread-onlycurrentGUID of socket group on BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7.2.1.4ColumnblueNet2SocketGroupNameread-onlycurrentName of the socket group connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7.2.1.5ColumnblueNet2SocketGroupFriendlyNameread-writecurrentUser friendlyname of the socket group connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7.2.1.6ColumnblueNet2SocketGroupDescriptionread-writecurrentDescription of the socket group connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7.2.1.7ColumnblueNet2SocketGroupStatusread-onlycurrentStatus of socket group.
1.3.6.1.4.1.31770.2.2.7.2.1.8ColumnblueNet2SocketGroupModeread-writecurrentMode of all the sockets of a socket group connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7.2.1.9ColumnblueNet2SocketGroupIdentifyread-writecurrentMode of all the socket leds of a socket group connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.7.2.1.10ColumnblueNet2SocketGroupEntPhysicalIndexread-onlycurrentCorresponding entPhysicalIndex of this socketgroup. 0 if none exists.
1.3.6.1.4.1.31770.2.2.7.2.1.11ColumnblueNet2SocketGroupAccumulatedStatusread-onlycurrentA bit field of all current socket group members states.
1.3.6.1.4.1.31770.2.2.7.2.1.12ColumnblueNet2SocketGroupMembersread-writecurrentThe set of sockets which are members of this socket group.
1.3.6.1.4.1.31770.2.2.8NodeblueNet2Variables
1.3.6.1.4.1.31770.2.2.8.1NodeblueNet2VariableInfo
1.3.6.1.4.1.31770.2.2.8.1.1ScalarblueNet2OverallVariableStatusread-onlycurrentOverall status of all variables.
1.3.6.1.4.1.31770.2.2.8.1.2ScalarblueNet2NumberOfVariablesread-onlycurrentNumber of variables available.
1.3.6.1.4.1.31770.2.2.8.1.3ScalarblueNet2LastChangeOverallVariableStatusread-onlycurrentTimestamp of last status change of any variables connected to BlueNet2 PDU according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.8.1.4ScalarblueNet2LastChangeNumberOfVariablesread-onlycurrentTimestamp of last variables number change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.8.1.5ScalarblueNet2LastChangeVariableSettingsread-onlycurrentTimestamp of last setting change of any variables connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP sett…
1.3.6.1.4.1.31770.2.2.8.1.6ScalarblueNet2LastChangeVariableStatusread-onlycurrentTimestamp of last variable status change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.8.1.7ScalarblueNet2VariablesAccumulatedStatusread-onlycurrentA bit field of all current variable states.
1.3.6.1.4.1.31770.2.2.8.1.8ScalarblueNet2NumberOfChangesVariableScalingread-onlycurrentNumber of changes in variable scaling due to overrun or reset. Variables are given most accurate, each using its own scaling. But some variables are accumulate…
1.3.6.1.4.1.31770.2.2.8.1.9ScalarblueNet2LastChangeVariableScalingread-onlycurrentTimestamp of last variable scaling change according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.8.1.10ScalarblueNet2LastChangeVariableResetread-onlycurrentTimestamp of last manually reset of a variable according to operating time sysUpTime.
1.3.6.1.4.1.31770.2.2.8.2TableblueNet2VariableTablenot-accessiblecurrentHeadline of variable table.
1.3.6.1.4.1.31770.2.2.8.2.1RowblueNet2VariableEntrynot-accessiblecurrentEntries of variable table.
1.3.6.1.4.1.31770.2.2.8.2.1.1ColumnblueNet2VariableIdnot-accessiblecurrentGUID of variable.
1.3.6.1.4.1.31770.2.2.8.2.1.2ColumnblueNet2VariableGuidread-onlycurrentGUID of variable.
1.3.6.1.4.1.31770.2.2.8.2.1.3ColumnblueNet2VariableNameread-onlycurrentName of the variable connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.8.2.1.4ColumnblueNet2VariableFriendlyNameread-onlycurrentUser friendlyname of the variable connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.8.2.1.5ColumnblueNet2VariableDescriptionread-onlycurrentDescription of the variable connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.8.2.1.6ColumnblueNet2VariableTyperead-onlycurrentType of variable.
1.3.6.1.4.1.31770.2.2.8.2.1.7ColumnblueNet2VariableStatusread-onlycurrentGeneral status of variable connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.8.2.1.8ColumnblueNet2VariableAlarmread-onlycurrentAlarm text of variable connected to BlueNet2 PDU.
1.3.6.1.4.1.31770.2.2.8.2.1.9ColumnblueNet2VariableScalingread-onlycurrentScaling of variable as 10^x.
1.3.6.1.4.1.31770.2.2.8.2.1.10ColumnblueNet2VariableUnitread-onlycurrentUnit of variable.
1.3.6.1.4.1.31770.2.2.8.2.1.11ColumnblueNet2VariableSetPointread-onlycurrentSet point supported for this variable.
1.3.6.1.4.1.31770.2.2.8.2.1.12ColumnblueNet2VariableModeread-writecurrentReset mode of a variable. Variables in mode reset(1) can by reset by writing reset(1). No other values than reset(1) can be written.
1.3.6.1.4.1.31770.2.2.8.2.1.13ColumnblueNet2VariableEntPhysicalIndexread-onlycurrentCorresponding entPhysicalIndex of this variable. 0 if none exists.
1.3.6.1.4.1.31770.2.2.8.3TableblueNet2VariableSetPointTablenot-accessiblecurrentHeadline of variable set point table.
1.3.6.1.4.1.31770.2.2.8.3.1RowblueNet2VariableSetPointEntrynot-accessiblecurrentEntries of variable set point table.
1.3.6.1.4.1.31770.2.2.8.3.1.1ColumnblueNet2VariableSetPointGuidnot-accessiblecurrentGUID of set point.
1.3.6.1.4.1.31770.2.2.8.3.1.2ColumnblueNet2VariableSetPointTyperead-onlycurrentType of setpoint.
1.3.6.1.4.1.31770.2.2.8.3.1.3ColumnblueNet2VariableSetPointMinValueread-onlycurrentMinimum value of setpoint.
1.3.6.1.4.1.31770.2.2.8.3.1.4ColumnblueNet2VariableSetPointMaxValueread-onlycurrentMaximum value of setpoint.
1.3.6.1.4.1.31770.2.2.8.3.1.5ColumnblueNet2VariableSetPointLowerAlarmread-writecurrentLower threshold of variable.
1.3.6.1.4.1.31770.2.2.8.3.1.6ColumnblueNet2VariableSetPointLowerWarningread-writecurrentLower Warning of variable.
1.3.6.1.4.1.31770.2.2.8.3.1.7ColumnblueNet2VariableSetPointUpperWarningread-writecurrentUpper warning of variable.
1.3.6.1.4.1.31770.2.2.8.3.1.8ColumnblueNet2VariableSetPointUpperAlarmread-writecurrentUpper threshold of variable.
1.3.6.1.4.1.31770.2.2.8.3.1.9ColumnblueNet2VariableSetPointHysteresisread-writecurrentHysteresis of variable.
1.3.6.1.4.1.31770.2.2.8.3.1.10ColumnblueNet2VariableSetPointRcmACUpperAlarmThresholdread-writecurrentUpper Alarm threshold of RCM AC.
1.3.6.1.4.1.31770.2.2.8.3.1.11ColumnblueNet2VariableSetPointRcmACUpperAlarmGradientread-writecurrentUpper Alarm gradient of RCM AC.
1.3.6.1.4.1.31770.2.2.8.3.1.12ColumnblueNet2VariableSetPointRcmACUpperWarningThresholdread-writecurrentUpper Warning threshold of RCM AC.
1.3.6.1.4.1.31770.2.2.8.3.1.13ColumnblueNet2VariableSetPointRcmACUpperWarningGradientread-writecurrentUpper Warning gradient of RCM AC.
1.3.6.1.4.1.31770.2.2.8.4TableblueNet2VariableDataTablenot-accessiblecurrentHeadline of variable data table. This table contains a subset of frequently changing variables as in blueNet2VariableDataTable, like measured values and status.
1.3.6.1.4.1.31770.2.2.8.4.1RowblueNet2VariableDataEntrynot-accessiblecurrentEntries of variable date table.
1.3.6.1.4.1.31770.2.2.8.4.1.1ColumnblueNet2VariableDataIdnot-accessiblecurrentGUID of variable.
1.3.6.1.4.1.31770.2.2.8.4.1.2ColumnblueNet2VariableDataGuidread-onlycurrentGUID of variable.
1.3.6.1.4.1.31770.2.2.8.4.1.3ColumnblueNet2VariableDataTyperead-onlycurrentType of variable.
1.3.6.1.4.1.31770.2.2.8.4.1.4ColumnblueNet2VariableDataStatusread-onlycurrentStatus of variable.
1.3.6.1.4.1.31770.2.2.8.4.1.5ColumnblueNet2VariableDataValueread-onlycurrentValue of variable.
1.3.6.1.4.1.31770.2.2.8.4.1.6ColumnblueNet2VariableDataDateTimeread-onlycurrentTimestamp of variable.
1.3.6.1.4.1.31770.2.2.8.5TableblueNet2VariableDataByTypeTablenot-accessiblecurrentHeadline of variable data by type table. This table contains a subset of frequently changing variables as in blueNet2VariableDataByTypeTable, like measured val…
1.3.6.1.4.1.31770.2.2.8.5.1RowblueNet2VariableDataByTypeEntrynot-accessiblecurrentEntries of variable data by type table.
1.3.6.1.4.1.31770.2.2.8.5.1.1ColumnblueNet2VariableDataByTypenot-accessiblecurrentType of variable.
1.3.6.1.4.1.31770.2.2.8.5.1.2ColumnblueNet2VariableDataByTypeGuidnot-accessiblecurrentGUID of variable.
1.3.6.1.4.1.31770.2.2.8.5.1.3ColumnblueNet2VariableDataByTypeTyperead-onlycurrentType of variable.
1.3.6.1.4.1.31770.2.2.8.5.1.4ColumnblueNet2VariableDataByTypeStatusread-onlycurrentStatus of variable.
1.3.6.1.4.1.31770.2.2.8.5.1.5ColumnblueNet2VariableDataByTypeValueread-onlycurrentValue of variable.
1.3.6.1.4.1.31770.2.2.8.5.1.6ColumnblueNet2VariableDataByTypeDateTimeread-onlycurrentTimestamp of variable.
1.3.6.1.4.1.31770.2.2.8.6TableblueNet2VariableDataByStateTablenot-accessibledeprecatedHeadline of variable data by state table. This table contains a subset of frequently changing variables as in blueNet2VariableDataByStateTable, like measured v…
1.3.6.1.4.1.31770.2.2.8.6.1RowblueNet2VariableDataByStateEntrynot-accessibledeprecatedEntries of variable data by state table.
1.3.6.1.4.1.31770.2.2.8.6.1.1ColumnblueNet2VariableDataByStatenot-accessibledeprecatedStatus of variable.
1.3.6.1.4.1.31770.2.2.8.6.1.2ColumnblueNet2VariableDataByStateGuidnot-accessibledeprecatedGUID of variable.
1.3.6.1.4.1.31770.2.2.8.6.1.3ColumnblueNet2VariableDataByStateTyperead-onlydeprecatedType of variable.
1.3.6.1.4.1.31770.2.2.8.6.1.4ColumnblueNet2VariableDataByStateStatusread-onlydeprecatedStatus of variable.
1.3.6.1.4.1.31770.2.2.8.6.1.5ColumnblueNet2VariableDataByStateValueread-onlydeprecatedValue of variable.
1.3.6.1.4.1.31770.2.2.8.6.1.6ColumnblueNet2VariableDataByStateDateTimeread-onlydeprecatedTimestamp of variable.
1.3.6.1.4.1.31770.2.2.8.7TableblueNet2VariableDataBySourceTablenot-accessiblecurrentHeadline of variable data by state table. This table contains a subset of frequently changing variables as in blueNet2VariableDataBySourceTable, like measured …
1.3.6.1.4.1.31770.2.2.8.7.1RowblueNet2VariableDataBySourceEntrynot-accessiblecurrentEntries of variable data by source table.
1.3.6.1.4.1.31770.2.2.8.7.1.1ColumnblueNet2VariableDataBySourcenot-accessiblecurrentSource of variable.
1.3.6.1.4.1.31770.2.2.8.7.1.2ColumnblueNet2VariableDataBySourceGuidnot-accessiblecurrentGUID of variable.
1.3.6.1.4.1.31770.2.2.8.7.1.3ColumnblueNet2VariableDataBySourceTyperead-onlycurrentType of variable.
1.3.6.1.4.1.31770.2.2.8.7.1.4ColumnblueNet2VariableDataBySourceStatusread-onlycurrentStatus of variable.
1.3.6.1.4.1.31770.2.2.8.7.1.5ColumnblueNet2VariableDataBySourceValueread-onlycurrentValue of variable.
1.3.6.1.4.1.31770.2.2.8.7.1.6ColumnblueNet2VariableDataBySourceDateTimeread-onlycurrentTimestamp of variable.
1.3.6.1.4.1.31770.2.2.9NodeblueNet2MPStates
1.3.6.1.4.1.31770.2.2.9.1TableblueNet2MPTablenot-accessiblecurrentHeadline of MP (Measurement Point) table.
1.3.6.1.4.1.31770.2.2.9.1.1RowblueNet2MPEntrynot-accessiblecurrentEntries of Measurement Point table.
1.3.6.1.4.1.31770.2.2.9.1.1.1ColumnblueNet2MPIDnot-accessiblecurrentGUID of a Measurement Point.
1.3.6.1.4.1.31770.2.2.9.1.1.2ColumnblueNet2MPGuidread-onlycurrentGUID of a Measurement Point.
1.3.6.1.4.1.31770.2.2.9.1.1.3ColumnblueNet2MPNameread-onlycurrentName of a Measurement Point.
1.3.6.1.4.1.31770.2.2.9.1.1.4ColumnblueNet2MPFriendlyNameread-onlycurrentUser friendlyname of a Measurement Point.
1.3.6.1.4.1.31770.2.2.9.1.1.5ColumnblueNet2MPStateread-onlycurrentStatus of a Measurement Point.
1.3.6.1.4.1.31770.2.2.9.1.1.6ColumnblueNet2MPTimeStampread-onlycurrentTimestamp of the last change of a Measurement Point.
1.3.6.1.4.1.31770.2.3NodeblueNet2Traps
1.3.6.1.4.1.31770.2.3.0NodeblueNet2TrapPrefix
1.3.6.1.4.1.31770.2.3.0.1NotificationblueNet2PduStatusOkTrapcurrentPDU status ok.
1.3.6.1.4.1.31770.2.3.0.2NotificationblueNet2PduStatusWarningTrapcurrentPDU status warning.
1.3.6.1.4.1.31770.2.3.0.3NotificationblueNet2PduStatusAlarmTrapcurrentPDU status alarm.
1.3.6.1.4.1.31770.2.3.0.4NotificationblueNet2SensorStatusOkTrapcurrentSensor status change.
1.3.6.1.4.1.31770.2.3.0.5NotificationblueNet2SensorStatusWarningTrapcurrentSensor status change.
1.3.6.1.4.1.31770.2.3.0.6NotificationblueNet2SensorStatusAlarmTrapcurrentSensor status change.
1.3.6.1.4.1.31770.2.3.0.7NotificationblueNet2VariableStatusOkTrapcurrentVariable status is ok.
1.3.6.1.4.1.31770.2.3.0.8NotificationblueNet2VariableLowerWarningTrapcurrentVariable status lower warning.
1.3.6.1.4.1.31770.2.3.0.9NotificationblueNet2VariableUpperWarningTrapcurrentVariable status upper warning.
1.3.6.1.4.1.31770.2.3.0.10NotificationblueNet2VariableLowerAlarmTrapcurrentVariable status lower alarm.
1.3.6.1.4.1.31770.2.3.0.11NotificationblueNet2VariableUpperAlarmTrapcurrentVariable status upper alarm.
1.3.6.1.4.1.31770.2.3.0.12NotificationblueNet2RCMSelftestResultTrapcurrentRCM Selftest result.
1.3.6.1.4.1.31770.2.3.0.98NotificationblueNet2ReconfigAgentTrapcurrentAgent reconfiguration.
1.3.6.1.4.1.31770.2.3.0.99NotificationblueNet2ShutdownAgentTrapcurrentAgent shutdown.
1.3.6.1.4.1.31770.2.4NodeblueNet2Conformance
1.3.6.1.4.1.31770.2.4.1NodeblueNet2Compliances
1.3.6.1.4.1.31770.2.4.1.1ComplianceblueNet2CompliancecurrentThe core compliance statement for all BlueNet2 PDU implementations.
1.3.6.1.4.1.31770.2.4.2NodeblueNet2Groups
1.3.6.1.4.1.31770.2.4.2.1GroupblueNet2TrapGroupcurrentConformance group for all objects contained in BlueNet2 PDU traps.
1.3.6.1.4.1.31770.2.4.2.2GroupblueNet2NotificationGroupcurrentConformance group for BlueNet2 PDU notifications.
1.3.6.1.4.1.31770.2.4.2.3GroupblueNet2IdentificationGroupcurrentConformance group for BlueNet2 PDU base identfication.
1.3.6.1.4.1.31770.2.4.2.4GroupblueNet2InformationGroupcurrentConformance group for BlueNet2 PDU base information.
1.3.6.1.4.1.31770.2.4.2.5GroupblueNet2ConfigurationGroupcurrentConformance group for BlueNet2 PDU base configuration.
1.3.6.1.4.1.31770.2.4.2.6GroupblueNet2SnmpGroupcurrentConformance group for BlueNet2 PDU SNMP configuration.
1.3.6.1.4.1.31770.2.4.2.7GroupblueNet2ModbusGroupcurrentConformance group for blueNet2 PDU modbus configuration.
1.3.6.1.4.1.31770.2.4.2.8GroupblueNet2NtpGroupcurrentConformance group for BlueNet2 PDU NTP configuration.
1.3.6.1.4.1.31770.2.4.2.9GroupblueNet2SmtpGroupcurrentConformance group for BlueNet2 PDU SMTP configuration.
1.3.6.1.4.1.31770.2.4.2.10GroupblueNet2SyslogGroupcurrentConformance group for BlueNet2 PDU syslog operations.
1.3.6.1.4.1.31770.2.4.2.11GroupblueNet2DeviceGroupcurrentConformance group for BlueNet2 PDU device information.
1.3.6.1.4.1.31770.2.4.2.12GroupblueNet2SensorGroupcurrentConformance group for BlueNet2 PDU sensor information.
1.3.6.1.4.1.31770.2.4.2.13GroupblueNet2CircuitGroupcurrentConformance group for BlueNet2 PDU circuit information.
1.3.6.1.4.1.31770.2.4.2.14GroupblueNet2PhaseGroupcurrentConformance group for BlueNet2 PDU phase information.
1.3.6.1.4.1.31770.2.4.2.15GroupblueNet2FuseGroupcurrentConformance group for BlueNet2 PDU fuse information.
1.3.6.1.4.1.31770.2.4.2.16GroupblueNet2SocketGroupcurrentConformance group for BlueNet2 PDU socket information.
1.3.6.1.4.1.31770.2.4.2.17GroupblueNet2RcmGroupcurrentConformance group for BlueNet2 PDU RCM information.
1.3.6.1.4.1.31770.2.4.2.18GroupblueNet2SocketGroupGroupcurrentConformance group for BlueNet2 PDU socket groups.
1.3.6.1.4.1.31770.2.4.2.19GroupblueNet2VariableGroupcurrentConformance group for BlueNet2 PDU variable information.
1.3.6.1.4.1.31770.2.4.2.20GroupblueNet2MPGroupcurrentConformance group for BlueNet2 Measurement Point information.
1.3.6.1.4.1.31770.2.4.2.21GroupblueNet2SpdGroupcurrentConformance group for BlueNet2 PDU SPD information.
Type Definitions
NameSyntaxStatusDescription
BlueNet2ComponentStatesINTEGER { ok (1), warning (2), alarm (3) }currentRepresents the possible values of component states.
BlueNet2DataSourceTypesINTEGER { voltage (1), peakVoltage (2), current (4), peakCurrent (5), differentialCurrentAc(7), differentialCurrentDc(8), neutralCurrent (9), phaseAngle (16), powerFactor (17), apparentPower (18), activePower (19), peakActivePower (20), peakActivePowerUser(21), reactivePower (22), frequency (23), peakNeutralCurrent(24), apparentEnergyAccumulated(32), apparentEnergyDelta(33), reactiveEnergyAccumulated(34), reactiveEnergyDelta(35), activeEnergyAccumulated(36), activeEnergyDelta(37), activeEnergyAccumulatedUser(38), activeEnergyRuntime(39), customEnergyRuntimeUser(40), fuseState (48), orientation (49), usb (50), socketState (51), pduState (52), sensorState (53), circuitState (54), phaseState (55), rcdState (56), socketGroupState (57), globalState (58), sensorType (64), circuitType (65), fuseType (66), socketType (67), socketColor (68), phaseType (69), pduType (70), rcmType (71), deltaVoltage12 (80), deltaVoltage23 (81), deltaVoltage31 (82), rcmACPeak (83), rcmDCPeak (84), temperature (256), humidity (257), ioInputChannel1 (258), ioInputChannel2 (259), ioInputChannel3 (260), ioInputChannel4 (261), ioOutputChannel1(262), ioOutputChannel2(263), ioOutputChannel3(264), ioOutputChannel4(265), dewPoint (266), pressure (267), diffPressure (268), co2Equivalent (269), tvoc (270), unspecified (65535) }currentRepresents the possible values of data sources. (1) voltage (2) peak voltage, can be reset by user (4) current (5) peak current, can be reset by user (7) differential current AC (8) differential current DC (9) neutral c…
BlueNet2DataSourceUnitsINTEGER { metre (1), kilogram (2), second (3), ampere (4), kelvin (5), mole (6), candela (7), radian (16), steradian (17), hertz (32), newton (33), pascal (34), joule (35), watt (36), coulomb (37), volt (38), farad (39), ohm (40), siemens (41), weber (42), tesla (43), henry (44), celsius (45), lumen (46), lux (47), becquerel (48), gray (49), sievert (50), katal (51), grade (64), degree (65), aMinuteAngle (66), aSecondAngle (67), litre (68), are (69), hectare (70), minute (71), hour (72), day (73), year (74), gram (75), tonne (76), bar (78), poise (79), stokes (80), electronvolt (81), atomicMass (82), astronomic (83), parsec (84), metrePerS2 (85), newtonMetre (86), s2 (87), m2 (88), m3 (89), pascalSecond (90), jPerKgK (91), wPerMK (92), jPerMoleK (93), wPerM2Sr (94), katPerM3 (95), kiloWattHour (240), percentage (241), va (242), var (243), kiloVaHour (244), kiloVarHour (245), milliAmpere (246), unit (255) }currentRepresents the possible units of data sources. Definitions according to CiA 2006.
BlueNet2EntityBitsOCTET STRING (SIZE (8..8))currentEach octet within this value specifies a set of eight BlueNet2EntityStates, with the first octet specifying 0 through 7, the second octet specifying states 8 through 15, etc. Within each octet, the most significant bit …
BlueNet2EntitySourcesINTEGER { other (1), device (2), sensor (3), circuit (4), phase (5), fuse (6), socket (7), socketgroup (8), rcm (9) }currentRepresents the possible source of entity variables.
BlueNet2EntityStatesINTEGER { expected (0), undefined (1), ok (2), errorHigh (3), errorLow (4), warningHigh (5), warningLow (6), lost (7), deactivate (8), onAlarmIdentidy (9), offAlarmIdentify(10), onAlarm (11), offAlarm (12), onWarningIdentify (13), offWarningIdentify (14), onWarning (15), offWarning (16), onIdentify (17), offIdentify (18), on (19), off (20), onChildAlarm (21), offChildAlarm (22), onChildWarning (23), offChildWarning (24), childAlarm (25), childWarning (26), lostChild (27), updateInProgress (36), updateError (37), onGoingSwitch (38), high (39), low (40), alarm (41), warning (42), ok (43), disabled (44), fwVersionTooNew (45) }currentRepresents the possible values of entity states.
BlueNet2GPIOModesINTEGER { disabled (0), enabled (2), s0 (6), undefined (7) }currentRepresents the mode of GPIO input or output.
BlueNet2GPIOSwitchINTEGER { undefined (0), switchable (3), notSwitchable (5), on (1), off (2) }currentRepresents the state to switch on/off GPIO output.
BlueNet2InfoMessageSourcesINTEGER { other (1), device (2), sensor (3), variable (4) }currentRepresents the source of a message.
BlueNet2RcmSelftestCommandINTEGER { selftestWithoutAnyNotification (0), selftestWithAlarmNotifyOnly (1), selftestWithSelftestNotifyOnly (2), selftestWithAlarmAndSelftestNotify (3), selftestCommand (4) }currentRepresents RCM self-test commands with or without alarm or selftest notifications.
BlueNet2RcmSelftestResultINTEGER { notRun (0), notReachable (1), success (2), failure (3), partialSuccess (4), cancelled (5), notApplicable (255) }currentRepresents RCM self-test result values.
BlueNet2SocketMembersOCTET STRING (SIZE (1..255))currentEach octet within this value specifies a set of eight sockets, with the first octet specifying sockets 1 through 8, the second octet specifying sockets 9 through 16, etc. Within each octet, the most significant bit repr…
BlueNet2SocketModesINTEGER { switchedOn (1), switchedOff (2), switchedOnAndOff(3), notAvailable (4), notSwitchable (5) }currentRepresents the mode of a socket or socket group or its LEDs. A socket or socket group can be notSwitchable or switchedOn/Off. A socket group may also have different sockets switchedOnAndOff. A socket or socket group can…