BASIS-SHELF-MIB
46 objects
No module-level DESCRIPTION found.
Imported Objects
| BASIS-MIB | axisRedundancy basisShelf |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | IpAddress |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.351.110.1.1.1 | TableshelfTable | not-accessible | mandatory | The table has the Physical slot number and state of the cards |
| 1.3.6.1.4.1.351.110.1.1.1.1 | RowshelfEntry | not-accessible | mandatory | An entry for the slot |
| 1.3.6.1.4.1.351.110.1.1.1.1.1 | ColumnshelfNum | read-only | mandatory | A unique value for each shelf. Its value ranges between 1 and the maxvalue of shelfNumber. |
| 1.3.6.1.4.1.351.110.1.1.1.1.2 | ColumnshelfSlotNum | read-only | mandatory | Slot number of a card. BASIS can have maximum 16 slots in one shelf. 17 is used to reset the whole shelf. Some MGX Series can have maximum 32 slots in one shel… |
| 1.3.6.1.4.1.351.110.1.1.1.1.3 | ColumnshelfBkplnSerialNumDeprecated | read-only | mandatory | This entry has been deprecated. It is available as the 9th entry in basisShelf. It is included here to prevent a hole in the shelfEntry table. |
| 1.3.6.1.4.1.351.110.1.1.1.1.4 | ColumnshelfFunctionModuleState | read-only | mandatory | This object holds the status of a card in a particular shelf-slot. The hold state is applicable only to MGX8800 Platform. The Slave PXM assumes the hold state … |
| 1.3.6.1.4.1.351.110.1.1.1.1.5 | ColumnshelfFunctionModuleType | read-only | mandatory | This object holds the type of a card in a particular shelf-slot. |
| 1.3.6.1.4.1.351.110.1.1.1.1.6 | ColumnshelfFunctionModuleHoldReset | read-write | mandatory | This object holds the card in a particular shelf-slot, in reset, If the object is set to holdInReset. If the object is set to doNotHold, then it only reset the… |
| 1.3.6.1.4.1.351.110.1.1.2 | ScalarshelfNumOfValidEntries | read-only | mandatory | Number of rows in shelfTable. In some MGX series, it is equal to the number of slots in the shelf. |
| 1.3.6.1.4.1.351.110.1.1.3 | ScalarshelfNodeName | read-write | mandatory | Has the node name of BASIS for MGX8220 only. For others NodeName supplied by PAR will be returned, A set on this MIB is not allowed. The NodeName of the shelf … |
| 1.3.6.1.4.1.351.110.1.1.4 | ScalarshelfDate | read-write | mandatory | This object sets/gets the DATE. The syntax is mm/dd/yyyy |
| 1.3.6.1.4.1.351.110.1.1.5 | ScalarshelfTime | read-write | mandatory | This object sets/gets the TIME. The syntax is hh:mm:ss |
| 1.3.6.1.4.1.351.110.1.1.6 | ScalarshelfTmZn | read-write | mandatory | Object defines standard time. GMT for greenwich mean time, est for Eastern std time (USA EST). cst for Central std time (USA CST). mst for Mountain std time (U… |
| 1.3.6.1.4.1.351.110.1.1.7 | ScalarshelfTmZnGMTOff | read-write | mandatory | This object contains the offset from greenwich mean time in hours, if configuring for std time in shelfTmZn object, set this object to 0. If configuring for no… |
| 1.3.6.1.4.1.351.110.1.1.8 | ScalarshelfBkPlnType | read-only | mandatory | This object contains the back plane type. The possible values are : 1 - For 336Mbps backplane 2 - For 1.2Gbps backplane 3 - For 45Gbps backplane |
| 1.3.6.1.4.1.351.110.1.1.9 | ScalarshelfBkplnSerialNum | read-only | mandatory | A unique value for each shelf, entered in nvram by manf. The serial No. is on the non-volatile RAM on the backplane. |
| 1.3.6.1.4.1.351.110.1.1.10 | ScalarstatsMasterIpAddress | read-only | mandatory | IP address of the Stats Master. |
| 1.3.6.1.4.1.351.110.1.1.11 | ScalarstatsCollectionInterval | read-only | mandatory | Statistics collection interval (in minutes). |
| 1.3.6.1.4.1.351.110.1.1.12 | ScalarstatsBucketInterval | read-only | mandatory | Statistics bucket interval (in minutes). |
| 1.3.6.1.4.1.351.110.1.1.13 | ScalaruserName | read-only | mandatory | username of the person logging in or logging out. used only in traps currently only limit to 12 chars |
| 1.3.6.1.4.1.351.110.1.1.14 | ScalarshelfIntegratedAlarm | read-only | mandatory | Alarm status of the shelf.An implementation may not support all the values. possible values are : clear (1) : shelf is not in alarm minor (2) : Indicates that … |
| 1.3.6.1.4.1.351.110.1.1.15 | ScalarshelfAlarmCardBitMap | read-only | mandatory | default value is 0, none of the cards is in alarm bit position represents the card physical slot number which is in alarm |
| 1.3.6.1.4.1.351.110.1.1.16 | ScalaraxisFeederTkNo | read-write | mandatory | ASC creates its cell/frame file based on the feeder trunk number. |
| 1.3.6.1.4.1.351.110.1.1.17 | ScalaraxisSvcBillingColInterval | read-write | mandatory | SVC billing collection interval (in 0, 15, 30 minute steps). |
| 1.3.6.1.4.1.351.110.1.1.18 | ScalaraxisSvcBillingBucketInterval | read-write | mandatory | SVC billing bucket interval (in 0, 5, 15, 30 minute steps). |
| 1.3.6.1.4.1.351.110.1.1.19 | ScalarapsIpAddress | read-write | mandatory | the IP address of the APS |
| 1.3.6.1.4.1.351.110.1.1.20 | ScalarredundantApsIpAddress | read-write | mandatory | the IP address of the redundant APS |
| 1.3.6.1.4.1.351.110.1.1.21 | ScalaraxisSvcBilling | read-write | mandatory | SVC billing feature. |
| 1.3.6.1.4.1.351.110.1.1.22 | TableshelfCBClkRateTable | not-accessible | mandatory | The table has the Clock Rates of each Cell Bus |
| 1.3.6.1.4.1.351.110.1.1.22.1 | RowshelfCBClkRateEntry | not-accessible | mandatory | An entry for the Cell Bus |
| 1.3.6.1.4.1.351.110.1.1.22.1.1 | ColumncBNum | read-only | mandatory | The number (1-8) designation for the Cell Bus. |
| 1.3.6.1.4.1.351.110.1.1.22.1.2 | ColumnclkRate | read-write | mandatory | The Cell Bus Clock Rate designation. |
| 1.3.6.1.4.1.351.110.1.1.23 | ScalarshelfPowerSupplyVoltage | read-only | mandatory | Power Supply voltage rating for some selected MGX Series. two-twenty (1): 220Volts AC. one-ten (2): 110Volts AC. |
| 1.3.6.1.4.1.351.110.1.3.1 | TablesmRedMapTable | not-accessible | mandatory | The table has the redundancy map for a service module. This table is for configuring redundancy for service modules. This table might contain entries for Core-… |
| 1.3.6.1.4.1.351.110.1.3.1.1 | RowsmRedMapEntry | not-accessible | mandatory | An entry for module(Service Module,Core-Card set) redundancy. Some implementations might have entries for the core-card set. The entries for core-card set may … |
| 1.3.6.1.4.1.351.110.1.3.1.1.1 | ColumnredPrimarySlotNum | read-write | mandatory | The index to the table. This is the slot number of the primary module in the redundant configuration. For MGX8850 Release 1.x,skip PXM slot 7,8,23,24, SRM slot… |
| 1.3.6.1.4.1.351.110.1.3.1.1.2 | ColumnredRowStatus | read-write | mandatory | This will add, delete or modify the redundancy Note that mod is NOT used but it is there for consistency. This object is for creating and deleting an entry in … |
| 1.3.6.1.4.1.351.110.1.3.1.1.3 | ColumnredPrimaryType | read-only | mandatory | This object holds the type of the primary card Some of the card types are not supported in the table but they are defined here for consistency with the shelf c… |
| 1.3.6.1.4.1.351.110.1.3.1.1.4 | ColumnredPrimaryState | read-only | mandatory | This object holds the state of the primary card Some of the states are not supported in the table but they are defined here for consistency with the cardStates… |
| 1.3.6.1.4.1.351.110.1.3.1.1.5 | ColumnredSecondarySlotNum | read-write | mandatory | This is the slot number of the redundant card for the primary card. SecondarySlotNum will be 0 when no secondary card covering the primary card. SecondarySlotN… |
| 1.3.6.1.4.1.351.110.1.3.1.1.6 | ColumnredSecondaryType | read-only | mandatory | This object holds the type of the redundant card Note that redSecondaryType is the same as redPrimaryType unless it is changed for a new service module. Some o… |
| 1.3.6.1.4.1.351.110.1.3.1.1.7 | ColumnredSecondaryState | read-only | mandatory | This object holds the state of the secondary card Supported values are : nocard (1) : Module not present in the slot standby (2) : Module is in 'standby' state… |
| 1.3.6.1.4.1.351.110.1.3.1.1.8 | ColumnredType | read-write | mandatory | This object describes the type of redundancy. The supported values are : yCable (1) : 1:1 (y cable) redundancy configuration. In this configuration,there is on… |
| 1.3.6.1.4.1.351.110.1.3.1.1.9 | ColumnredCoveringSlot | read-only | mandatory | This is the slot number of the primary card for which the secondary card is covering Note that redCoveringSlot is set to 0 when the primary is not being protec… |
| 1.3.6.1.4.1.351.110.1.3.1.1.10 | ColumnredFeature | read-only | mandatory | This is the feature of the primary card. |
| 1.3.6.1.4.1.351.110.1.3.1.1.11 | ColumnredLineModuleType | read-only | mandatory | This is the line module type for the primary card. This object is NOT configurable and it only has the type of the current line module that is present in this … |