MIB Viewer

BAY-STACK-LLDP-EXT-DOT3-MIB

20 objects
This MIB module is an extension to the standard LLDP-EXT-DOT3 MIB.
OIDNameAccessStatusDescription
1.3.6.1.4.1.45.5.47IdentitybayStackLldpXDot3MibThis MIB module is an extension to the standard LLDP-EXT-DOT3 MIB.
1.3.6.1.4.1.45.5.47.0NodebsLldpXDot3Notifications
1.3.6.1.4.1.45.5.47.1NodebsLldpXDot3Objects
1.3.6.1.4.1.45.5.47.1.1NodebsLldpXdot3Config
1.3.6.1.4.1.45.5.47.1.2NodebsLldpXdot3LocalData
1.3.6.1.4.1.45.5.47.1.2.1TablebsLldpXdot3LocPowerTablenot-accessiblecurrentThis table contains one row per port of PSE PoE information on the local system known to this agent.
1.3.6.1.4.1.45.5.47.1.2.1.1RowbsLldpXdot3LocPowerEntrynot-accessiblecurrentInformation about a particular port PoE information.
1.3.6.1.4.1.45.5.47.1.2.1.1.1ColumnbsLldpXdot3LocPowerTyperead-onlycurrentA GET attribute that returns whether the local system is a PSE or a PD and whether it is Type 1 or Type 2.
1.3.6.1.4.1.45.5.47.1.2.1.1.2ColumnbsLldpXdot3LocPowerSourceread-onlycurrentA GET attribute indicating the PSE Power Sources of the local system. A PSE indicates whether it is being powered by a primary power source; a backup power sou…
1.3.6.1.4.1.45.5.47.1.2.1.1.3ColumnbsLldpXdot3LocPowerPriorityread-onlycurrentReflects the PD power priority that is being advertised on this PSE port. If both locally configure priority and ldpXMedRemXPoEPDPowerPriority are available on…
1.3.6.1.4.1.45.5.47.1.2.1.1.4ColumnbsLldpXdot3LocPDRequestedPowerValueread-onlycurrentA GET attribute that returns the PD requested power value. For a PSE, it is the power value that the PSE mirrors back to the remote system. This is the PD requ…
1.3.6.1.4.1.45.5.47.1.2.1.1.5ColumnbsLldpXdot3LocPSEAllocatedPowerValueread-onlycurrentA GET attribute that returns the PSE allocated power value. For a PSE, it is the power value that the PSE has currently allocated to the remote system. The PSE…
1.3.6.1.4.1.45.5.47.1.3NodebsLldpXdot3RemoteData
1.3.6.1.4.1.45.5.47.1.3.1TablebsLldpXdot3RemPowerTablenot-accessiblecurrentThis table contains information about the PoE device type as advertised by the remote system.
1.3.6.1.4.1.45.5.47.1.3.1.1RowbsLldpXdot3RemPowerEntrynot-accessiblecurrentInformation about a particular port component.
1.3.6.1.4.1.45.5.47.1.3.1.1.1ColumnbsLldpXdot3RemPowerTyperead-onlycurrentA GET attribute that returns whether the remote system is a PSE or a PD and whether it is Type 1 or Type 2.
1.3.6.1.4.1.45.5.47.1.3.1.1.2ColumnbsLldpXdot3RemPowerSourceread-onlycurrentA GET attribute that returns the power sources of the remote system. When the remote system is a PD, it indicates whether it is being powered by: a PSE and loc…
1.3.6.1.4.1.45.5.47.1.3.1.1.3ColumnbsLldpXdot3RemPowerPriorityread-onlycurrentA GET operation returns the priority of the PD system received from the remote system. For a PD, this is the priority that the remote system has assigned to th…
1.3.6.1.4.1.45.5.47.1.3.1.1.4ColumnbsLldpXdot3RemPDRequestedPowerValueread-onlycurrentA GET attribute that for a PSE returs the the PD requested power value received from the remote system. It is expressed in units of 0.1 watts.
1.3.6.1.4.1.45.5.47.1.3.1.1.5ColumnbsLldpXdot3RemPSEAllocatedPowerValueread-onlycurrentA GET attribute that for a PSE returns the PSE allocated power value that was used by the remote system to compute the power value that it has currently reques…