BAY-STACK-LLDP-EXT-DOT3-MIB
20 objects
This MIB module is an extension to the standard LLDP-EXT-DOT3 MIB.
Imported Objects
| LLDP-EXT-DOT3-MIB | lldpXdot3LocPowerEntry lldpXdot3RemPowerEntry |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SYNOPTICS-ROOT-MIB | bayStackMibs |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.45.5.47 | IdentitybayStackLldpXDot3Mib | This MIB module is an extension to the standard LLDP-EXT-DOT3 MIB. | ||
| 1.3.6.1.4.1.45.5.47.0 | NodebsLldpXDot3Notifications | |||
| 1.3.6.1.4.1.45.5.47.1 | NodebsLldpXDot3Objects | |||
| 1.3.6.1.4.1.45.5.47.1.1 | NodebsLldpXdot3Config | |||
| 1.3.6.1.4.1.45.5.47.1.2 | NodebsLldpXdot3LocalData | |||
| 1.3.6.1.4.1.45.5.47.1.2.1 | TablebsLldpXdot3LocPowerTable | not-accessible | current | This table contains one row per port of PSE PoE information on the local system known to this agent. |
| 1.3.6.1.4.1.45.5.47.1.2.1.1 | RowbsLldpXdot3LocPowerEntry | not-accessible | current | Information about a particular port PoE information. |
| 1.3.6.1.4.1.45.5.47.1.2.1.1.1 | ColumnbsLldpXdot3LocPowerType | read-only | current | A GET attribute that returns whether the local system is a PSE or a PD and whether it is Type 1 or Type 2. |
| 1.3.6.1.4.1.45.5.47.1.2.1.1.2 | ColumnbsLldpXdot3LocPowerSource | read-only | current | A GET attribute indicating the PSE Power Sources of the local system. A PSE indicates whether it is being powered by a primary power source; a backup power sou… |
| 1.3.6.1.4.1.45.5.47.1.2.1.1.3 | ColumnbsLldpXdot3LocPowerPriority | read-only | current | Reflects the PD power priority that is being advertised on this PSE port. If both locally configure priority and ldpXMedRemXPoEPDPowerPriority are available on… |
| 1.3.6.1.4.1.45.5.47.1.2.1.1.4 | ColumnbsLldpXdot3LocPDRequestedPowerValue | read-only | current | A GET attribute that returns the PD requested power value. For a PSE, it is the power value that the PSE mirrors back to the remote system. This is the PD requ… |
| 1.3.6.1.4.1.45.5.47.1.2.1.1.5 | ColumnbsLldpXdot3LocPSEAllocatedPowerValue | read-only | current | A GET attribute that returns the PSE allocated power value. For a PSE, it is the power value that the PSE has currently allocated to the remote system. The PSE… |
| 1.3.6.1.4.1.45.5.47.1.3 | NodebsLldpXdot3RemoteData | |||
| 1.3.6.1.4.1.45.5.47.1.3.1 | TablebsLldpXdot3RemPowerTable | not-accessible | current | This table contains information about the PoE device type as advertised by the remote system. |
| 1.3.6.1.4.1.45.5.47.1.3.1.1 | RowbsLldpXdot3RemPowerEntry | not-accessible | current | Information about a particular port component. |
| 1.3.6.1.4.1.45.5.47.1.3.1.1.1 | ColumnbsLldpXdot3RemPowerType | read-only | current | A GET attribute that returns whether the remote system is a PSE or a PD and whether it is Type 1 or Type 2. |
| 1.3.6.1.4.1.45.5.47.1.3.1.1.2 | ColumnbsLldpXdot3RemPowerSource | read-only | current | A GET attribute that returns the power sources of the remote system. When the remote system is a PD, it indicates whether it is being powered by: a PSE and loc… |
| 1.3.6.1.4.1.45.5.47.1.3.1.1.3 | ColumnbsLldpXdot3RemPowerPriority | read-only | current | A GET operation returns the priority of the PD system received from the remote system. For a PD, this is the priority that the remote system has assigned to th… |
| 1.3.6.1.4.1.45.5.47.1.3.1.1.4 | ColumnbsLldpXdot3RemPDRequestedPowerValue | read-only | current | A GET attribute that for a PSE returs the the PD requested power value received from the remote system. It is expressed in units of 0.1 watts. |
| 1.3.6.1.4.1.45.5.47.1.3.1.1.5 | ColumnbsLldpXdot3RemPSEAllocatedPowerValue | read-only | current | A GET attribute that for a PSE returns the PSE allocated power value that was used by the remote system to compute the power value that it has currently reques… |