BENU-CHASSIS-MIB
83 objects
Initial creation MIB module for Benu Networks Chassis. Copyright (C) 2001, 2008 by Benu Networks, Inc. All rights reserved.
Imported Objects
| BENU-PLATFORM-MIB | benuPlatform |
| IF-MIB | ifAdminStatus ifDescr ifIndex ifOperStatus ifType |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.39406.1.1 | IdentitybenuChassisMIB | Initial creation MIB module for Benu Networks Chassis. Copyright (C) 2001, 2008 by Benu Networks, Inc. All rights reserved. | ||
| 1.3.6.1.4.1.39406.1.1.0 | NodebenuChassisNotifObjects | |||
| 1.3.6.1.4.1.39406.1.1.0.1 | NotificationbenuChassisPowerFailure | obsolete | A chassisPowerFailureTrap is generated when a Power Failure is detected in the system | |
| 1.3.6.1.4.1.39406.1.1.0.2 | NotificationbenuChassisFanFailureTrap | current | A chassisFanFailureTrap is generated when a Fan Failure is detected in the system | |
| 1.3.6.1.4.1.39406.1.1.0.3 | NotificationbenuLinkUpTrap | current | A proprietary Link Up Notification for all interfaces. This notification contains more details than the standard 'linkUp' notification in RFC 2863. | |
| 1.3.6.1.4.1.39406.1.1.0.4 | NotificationbenuLinkDownTrap | current | A proprietary Link Down Notification for all interfaces. This notification contains more details than the standard 'linkDown' notification in RFC 2863. | |
| 1.3.6.1.4.1.39406.1.1.0.5 | NotificationbenuSensorCritical | current | This notification signifies the transition of the sensor state from normal to critical. | |
| 1.3.6.1.4.1.39406.1.1.0.6 | NotificationbenuSensorNormal | current | This notification signifies the transition of the sensor state from critical to normal. | |
| 1.3.6.1.4.1.39406.1.1.0.7 | NotificationbenuChassisPowerFault | current | A chassisPowerFaultTrap is generated when a Power Failure is detected in the system | |
| 1.3.6.1.4.1.39406.1.1.0.8 | NotificationbenuChassisPowerRecovery | current | A chassisPowerRecoveryTrap is generated when a failed Power supply recovery is detected in the system | |
| 1.3.6.1.4.1.39406.1.1.0.9 | NotificationbenuChassisPowerPresent | current | A chassisPowerPresentTrap is generated when a redundant Power supply is inserted in the system | |
| 1.3.6.1.4.1.39406.1.1.0.10 | NotificationbenuChassisPowerAbsent | current | A chassisPowerAbsentTrap is generated when a redundant Power supply is removed from the system | |
| 1.3.6.1.4.1.39406.1.1.1 | NodebenuChassisMIBObjects | |||
| 1.3.6.1.4.1.39406.1.1.1.1 | NodebenuChassisInfo | |||
| 1.3.6.1.4.1.39406.1.1.1.1.1 | ScalarbenuChassisType | read-only | current | Chassis type. |
| 1.3.6.1.4.1.39406.1.1.1.1.2 | ScalarbenuChassisHwVersion | read-only | current | Chassis hardware revision level, or an empty string if unavailable. |
| 1.3.6.1.4.1.39406.1.1.1.1.3 | ScalarbenuChassisId | read-only | current | Unique ID string. Defaults to chassis serial number if available, otherwise empty |
| 1.3.6.1.4.1.39406.1.1.1.1.4 | ScalarbenuChassisNumOfSlots | read-only | current | Number of slots in this chassis, or -1 if neither applicable nor determinable. |
| 1.3.6.1.4.1.39406.1.1.1.1.5 | ScalarbenuChassisPowerTrapEnable | read-write | current | This object controls SNMP traps for chassis Power Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps… |
| 1.3.6.1.4.1.39406.1.1.1.1.6 | ScalarbenuChassisFanTrapEnable | read-write | current | This object controls SNMP traps for chassis Fan Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps a… |
| 1.3.6.1.4.1.39406.1.1.1.1.7 | ScalarbenuChassisSensorTrapEnable | read-write | current | This object controls SNMP traps for chassis senor Failure. If its value is set to enabled(1), then traps are generated. If the value is disabled(2), then traps… |
| 1.3.6.1.4.1.39406.1.1.1.1.8 | ScalarbenuSysUpTimeAtLastChassisChange | read-only | current | Time (in hundredths of a second) from the last cold start to the last change in the chassis' configuration. This value will be updated whenever the chassis exp… |
| 1.3.6.1.4.1.39406.1.1.1.2 | NodebenuCardInfo | |||
| 1.3.6.1.4.1.39406.1.1.1.2.1 | TablebenuCardTable | not-accessible | current | Chassis card table. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1 | RowbenuCardEntry | not-accessible | current | Chassis card table. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.1 | ColumnbenuCardIndex | not-accessible | current | Index into cardTable (not physical chassis slot number). |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.2 | ColumnbenuCardType | read-only | current | Functional type of this card. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.3 | ColumnbenuCardDescr | read-only | current | Text description of this card. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.4 | ColumnbenuCardSerial | read-only | current | The serial number of this card, or zero if unavailable. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.5 | ColumnbenuCardPartNumber | read-only | current | The part number of this card, or an empty string if unavailable. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.6 | ColumnbenuCardHwVersion | read-only | current | Hardware revision level of this card, or an empty string if unavailable. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.7 | ColumnbenuCardSwVersion | read-only | current | Version of the firmware or microcode installed on this card, or an empty string if unavailable. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.8 | ColumnbenuCardSlotNumber | read-only | current | Slot number relative to the containing card or chassis, or -1 if neither applicable nor determinable. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.9 | ColumnbenuCardRamSize | read-only | current | Number of kilobytes of DRAM. A value -1 means not available / not applicable A value 0 means internal error. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.10 | ColumnbenuCardPrimaryDiskSize | read-only | current | Number of kilobytes of Disk Memory (SATA or Hard Disk). A value -1 means not available / not applicable. A value 0 means internal error. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.11 | ColumnbenuCardSecondaryDiskSize | read-only | current | Number of kilobytes of Disk Memory (SATA or Hard Disk). A value -1 means not available / not applicable. A value 0 means internal error. |
| 1.3.6.1.4.1.39406.1.1.1.2.1.1.12 | ColumnbenuCardOperStatus | read-only | current | The operational status of the card. cardOperStatus is up when a card is recognized by the device and is enabled for operation. cardOperStatus is down if the ca… |
| 1.3.6.1.4.1.39406.1.1.1.3 | NodebenuCardIfInfo | |||
| 1.3.6.1.4.1.39406.1.1.1.3.1 | TablebenuCardIfIndexTable | not-accessible | current | Chassis card Interface table. |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1 | RowbenuCardIfIndexEntry | not-accessible | current | Chassis card table. |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.1 | ColumnbenuCardIfIndex | not-accessible | current | matches RFC1213 ifTable IfIndex |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.2 | ColumnbenuCardIfName | read-only | current | matches RFC1213 ifXTable IfName |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.3 | ColumnbenuCardIfPortNumber | read-only | current | Chassis port number, unique per port on a given card if available. |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.4 | ColumnbenuCardIfSlotNumber | read-only | current | Physical slot number of the card in the Chassis which contains this interface |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.5 | ColumnbenuCardIfLinkUpDownEnable | read-write | current | This enables and disables the sending of the proprietary notifications 'benuLinkUpTrap' and 'benuLinkDownTrap' that provide more information than the standard … |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.6 | ColumnbenuCardIfPortType | read-only | current | This object is used to identify port types for a given card. |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.7 | ColumnbenuCardIfBindName | read-only | current | interface name which is bound to this port . This string will be empty if there is no interface bind to this port |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.8 | ColumnbenuCardIfEncapsulation | read-only | current | The encapsulation method used by the port. |
| 1.3.6.1.4.1.39406.1.1.1.3.1.1.9 | ColumnbenuCardIfVirtualType | read-only | current | This object is used to identify virtualized interfaces. |
| 1.3.6.1.4.1.39406.1.1.1.4 | NodebenuSensorInfo | |||
| 1.3.6.1.4.1.39406.1.1.1.4.1 | TablebenuSensorTable | not-accessible | current | Chassis card table. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1 | RowbenuSensorEntry | not-accessible | current | Chassis card table. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.1 | ColumnbenuSensorCardIndex | not-accessible | current | cardIndex of the card in the Chassis cardTable which contains this sensor. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.2 | ColumnbenuSensorIndex | not-accessible | current | Index into sensorTable. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.3 | ColumnbenuSensorName | read-only | current | Name of the sensor. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.4 | ColumnbenuSensorType | read-only | current | Type of the sensor. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.5 | ColumnbenuSensorValue | read-only | current | |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.6 | ColumnbenuSensorMinThresh | read-only | current | Minimum threshold for this sensor. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.7 | ColumnbenuSensorMaxThresh | read-only | current | Maximum threshold for this sensor. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.8 | ColumnbenuSensorState | read-only | current | State of the sensor. |
| 1.3.6.1.4.1.39406.1.1.1.4.1.1.9 | ColumnbenuSensorId | read-only | current | Unique ID of the sensor. |
| 1.3.6.1.4.1.39406.1.1.1.5 | NodebenuChassisGeneralInfo | |||
| 1.3.6.1.4.1.39406.1.1.1.5.1 | ScalarbenuSysUpTimeSinceLastConfigChange | read-only | current | The time (in hundredths of a second) since the last configuration change in the system. |
| 1.3.6.1.4.1.39406.1.1.1.6 | NodebenuFanInfo | |||
| 1.3.6.1.4.1.39406.1.1.1.6.1 | TablebenuFanTable | not-accessible | current | Chassis Fan table. |
| 1.3.6.1.4.1.39406.1.1.1.6.1.1 | RowbenuFanEntry | not-accessible | current | Chassis card table. |
| 1.3.6.1.4.1.39406.1.1.1.6.1.1.1 | ColumnbenuFanCardIndex | not-accessible | current | cardIndex of the card in the Chassis cardTable which contains this Fan. |
| 1.3.6.1.4.1.39406.1.1.1.6.1.1.2 | ColumnbenuFanMaxSpeed | read-only | current | Maximum expected speed of each Fan. This value is applicable to all Fans in the card. Units : The value range is from 0 to 100 |
| 1.3.6.1.4.1.39406.1.1.1.6.1.1.3 | ColumnbenuFanCurSpeed | read-only | current | Current speed of each Fan. This value is applicable to all Fans in the card. Units : The value range is from 0 to 100 and is less than or equal to benuFanMaxSp… |
| 1.3.6.1.4.1.39406.1.1.1.6.1.1.4 | ColumnbenuFanStatus | read-only | current | A value of -1 means Not available / Not applicable. The lower order 7 bits indicates status of 7 Fans. A bit value of one indicates FAN is non-operational. A b… |
| 1.3.6.1.4.1.39406.1.1.1.7 | NodebenuPowerSupplyInfo | |||
| 1.3.6.1.4.1.39406.1.1.1.7.1 | TablebenuPowerSupplyTable | not-accessible | current | Benu power supply state information. |
| 1.3.6.1.4.1.39406.1.1.1.7.1.1 | RowbenuPowerSupplyEntry | not-accessible | current | Power supply table. |
| 1.3.6.1.4.1.39406.1.1.1.7.1.1.1 | ColumnbenuPowerSupplyIndex | not-accessible | current | This object is used to identify the power supply. |
| 1.3.6.1.4.1.39406.1.1.1.7.1.1.2 | ColumnbenuPowerSupplyName | read-only | current | The name of the power supply. |
| 1.3.6.1.4.1.39406.1.1.1.7.1.1.3 | ColumnbenuPowerSupplyPresent | read-only | current | Indicates whether or not the power supply is installed in the chassis. |
| 1.3.6.1.4.1.39406.1.1.1.7.1.1.4 | ColumnbenuPowerSupplyType | read-only | current | Indicates the type of the power supply. |
| 1.3.6.1.4.1.39406.1.1.1.7.1.1.5 | ColumnbenuPowerSupplyPowered | read-only | current | Indicates whether or not the power supply is actively supplying power. The value of notApplicable(3) will show if the entry for benuPowerSupplyPresent is no(2). |
| 1.3.6.1.4.1.39406.1.1.2 | NodebenuChassisNotifVariables | |||
| 1.3.6.1.4.1.39406.1.1.2.1 | ScalarbenuChassisPowerFailureInfo | accessible-for-notify | obsolete | Indicates the location of the Power Failure. |
| 1.3.6.1.4.1.39406.1.1.2.2 | ScalarbenuChassisFanFailureInfo | accessible-for-notify | current | Indicates the location of the Fan Failure. |
| 1.3.6.1.4.1.39406.1.1.2.3 | ScalarbenuChassisPowerFailureCardInfo | accessible-for-notify | obsolete | Indicates the Card Index Card Index starts from #1. |
| 1.3.6.1.4.1.39406.1.1.2.4 | ScalarbenuChassisPowerInfo | accessible-for-notify | current | Indicates the location of the Power Failure or recovery. |