BIANCA-BRICK-PMX-MIB
22 objects
No module-level DESCRIPTION found.
Imported Objects
| BINTEC-MIB MISSING | Date HexValue |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.272 | Nodebintec | |||
| 1.3.6.1.4.1.272.4 | Nodebibo | |||
| 1.3.6.1.4.1.272.4.12 | Nodepmx | |||
| 1.3.6.1.4.1.272.4.12.1 | TablepmxIfTable | not-accessible | mandatory | The pmxIfTable contains information relating to the interfaces found on the system. Each entry corresponds to a connected primary rate interface. Entries can o… |
| 1.3.6.1.4.1.272.4.12.1.1 | RowpmxIfEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.272.4.12.1.1.1 | ColumnpmxIfIndex | read-only | mandatory | Unique Index of the primary rate interface. The index is similar to slotnumber * 1000 and is also refenced in the ifTable, the isdnIfTable and in the isdnStkTa… |
| 1.3.6.1.4.1.272.4.12.1.1.2 | ColumnpmxIfSelftest | read-only | mandatory | The result of the initial selftest of the PMX module If the result is not succesful, the module is disabled successful(1) All selftests succeeded; acfa-failure… |
| 1.3.6.1.4.1.272.4.12.1.1.3 | ColumnpmxIfLayer1State | read-write | mandatory | The layer 1 state of the primary rate interface active(F1) active, framing and synchronisation is o.k. This is the only state where data-transmission is possib… |
| 1.3.6.1.4.1.272.4.12.1.1.4 | ColumnpmxIfLayer1Mode | read-only | mandatory | In T1 and E1 mode the primary rate interface is working with totaly different clock frequencies, framing and impedance. This depends on one of the jumpers on t… |
| 1.3.6.1.4.1.272.4.12.1.1.5 | ColumnpmxIfLayer1Framing | read-write | mandatory | In T1 and E1 mode the primary rate interface can work with totaly different framing types on layer 1. The framing type must match the configuration of the firs… |
| 1.3.6.1.4.1.272.4.12.1.1.6 | ColumnpmxIfLayer1LineCode | read-write | mandatory | In T1 mode the primary rate interface is able to work with different line codes. e1-hdb3(1) High Density Bipolar 3 Level Coding This is the only valid linecodi… |
| 1.3.6.1.4.1.272.4.12.1.1.7 | ColumnpmxIfChannelMode | read-write | mandatory | In T1 and E1 mode the primary rate interface may work with different channel types. Usually every timeslot is similar to one channel but it is also possible to… |
| 1.3.6.1.4.1.272.4.12.1.1.8 | ColumnpmxIfLoopbackMode | read-write | mandatory | Loopback-Mode is only required for equipment test no-loop(1) do not loopanything, this is the correct mode for normal operation full-loop(2) loopback everythin… |
| 1.3.6.1.4.1.272.4.12.1.1.9 | ColumnpmxIfErrors | read-only | mandatory | The measured PMX interface errors since startup |
| 1.3.6.1.4.1.272.4.12.1.1.10 | ColumnpmxIfPortMode | read-write | mandatory | PortMode switches the CM-PRI's 'Out'-port normal(1) 'Out'-port is disabled, this CM-PRI is connected to 'In' go-thru(2) 'Out'-port is enabled, this CM-PRI is d… |
| 1.3.6.1.4.1.272.4.12.1.1.21 | ColumnpmxIfLOS | read-only | mandatory | Loss Of Signal conditions since startup |
| 1.3.6.1.4.1.272.4.12.1.1.22 | ColumnpmxIfNoFAS | read-only | mandatory | Loss Of Frame Alignment conditions since startup |
| 1.3.6.1.4.1.272.4.12.1.1.23 | ColumnpmxIfRemoteAlarms | read-only | mandatory | Remote Alarms received since startup |
| 1.3.6.1.4.1.272.4.12.1.1.24 | ColumnpmxIfAlarmInds | read-only | mandatory | Alarms received since startup |
| 1.3.6.1.4.1.272.4.12.1.1.25 | ColumnpmxIfCRC4Errors | read-only | mandatory | CRC4 errors detected since startup |
| 1.3.6.1.4.1.272.4.12.1.1.26 | ColumnpmxIfSlipPositive | read-only | mandatory | Positive Slip conditions detected since startup; flags that the frequency of receive clock is less than frequency of internal system clock |
| 1.3.6.1.4.1.272.4.12.1.1.27 | ColumnpmxIfSlipNegative | read-only | mandatory | Negative Slip conditions detected since startup; flags that the frequency of receive clock is greater than frequency of internal system clock |