MIB Viewer

BIANCA-BRICK-PMX-MIB

22 objects
No module-level DESCRIPTION found.
Imported Objects
BINTEC-MIB MISSINGDate HexValue
RFC-1212OBJECT-TYPE
RFC1155-SMICounter enterprises
OIDNameAccessStatusDescription
1.3.6.1.4.1.272Nodebintec
1.3.6.1.4.1.272.4Nodebibo
1.3.6.1.4.1.272.4.12Nodepmx
1.3.6.1.4.1.272.4.12.1TablepmxIfTablenot-accessiblemandatoryThe pmxIfTable contains information relating to the interfaces found on the system. Each entry corresponds to a connected primary rate interface. Entries can o…
1.3.6.1.4.1.272.4.12.1.1RowpmxIfEntrynot-accessiblemandatory
1.3.6.1.4.1.272.4.12.1.1.1ColumnpmxIfIndexread-onlymandatoryUnique Index of the primary rate interface. The index is similar to slotnumber * 1000 and is also refenced in the ifTable, the isdnIfTable and in the isdnStkTa…
1.3.6.1.4.1.272.4.12.1.1.2ColumnpmxIfSelftestread-onlymandatoryThe result of the initial selftest of the PMX module If the result is not succesful, the module is disabled successful(1) All selftests succeeded; acfa-failure…
1.3.6.1.4.1.272.4.12.1.1.3ColumnpmxIfLayer1Stateread-writemandatoryThe layer 1 state of the primary rate interface active(F1) active, framing and synchronisation is o.k. This is the only state where data-transmission is possib…
1.3.6.1.4.1.272.4.12.1.1.4ColumnpmxIfLayer1Moderead-onlymandatoryIn T1 and E1 mode the primary rate interface is working with totaly different clock frequencies, framing and impedance. This depends on one of the jumpers on t…
1.3.6.1.4.1.272.4.12.1.1.5ColumnpmxIfLayer1Framingread-writemandatoryIn T1 and E1 mode the primary rate interface can work with totaly different framing types on layer 1. The framing type must match the configuration of the firs…
1.3.6.1.4.1.272.4.12.1.1.6ColumnpmxIfLayer1LineCoderead-writemandatoryIn T1 mode the primary rate interface is able to work with different line codes. e1-hdb3(1) High Density Bipolar 3 Level Coding This is the only valid linecodi…
1.3.6.1.4.1.272.4.12.1.1.7ColumnpmxIfChannelModeread-writemandatoryIn T1 and E1 mode the primary rate interface may work with different channel types. Usually every timeslot is similar to one channel but it is also possible to…
1.3.6.1.4.1.272.4.12.1.1.8ColumnpmxIfLoopbackModeread-writemandatoryLoopback-Mode is only required for equipment test no-loop(1) do not loopanything, this is the correct mode for normal operation full-loop(2) loopback everythin…
1.3.6.1.4.1.272.4.12.1.1.9ColumnpmxIfErrorsread-onlymandatoryThe measured PMX interface errors since startup
1.3.6.1.4.1.272.4.12.1.1.10ColumnpmxIfPortModeread-writemandatoryPortMode switches the CM-PRI's 'Out'-port normal(1) 'Out'-port is disabled, this CM-PRI is connected to 'In' go-thru(2) 'Out'-port is enabled, this CM-PRI is d…
1.3.6.1.4.1.272.4.12.1.1.21ColumnpmxIfLOSread-onlymandatoryLoss Of Signal conditions since startup
1.3.6.1.4.1.272.4.12.1.1.22ColumnpmxIfNoFASread-onlymandatoryLoss Of Frame Alignment conditions since startup
1.3.6.1.4.1.272.4.12.1.1.23ColumnpmxIfRemoteAlarmsread-onlymandatoryRemote Alarms received since startup
1.3.6.1.4.1.272.4.12.1.1.24ColumnpmxIfAlarmIndsread-onlymandatoryAlarms received since startup
1.3.6.1.4.1.272.4.12.1.1.25ColumnpmxIfCRC4Errorsread-onlymandatoryCRC4 errors detected since startup
1.3.6.1.4.1.272.4.12.1.1.26ColumnpmxIfSlipPositiveread-onlymandatoryPositive Slip conditions detected since startup; flags that the frequency of receive clock is less than frequency of internal system clock
1.3.6.1.4.1.272.4.12.1.1.27ColumnpmxIfSlipNegativeread-onlymandatoryNegative Slip conditions detected since startup; flags that the frequency of receive clock is greater than frequency of internal system clock