MIB Viewer

BIANCA-BRICK-SERIAL-MIB

33 objects
No module-level DESCRIPTION found.
Imported Objects
BINTEC-MIB MISSINGDate HexValue
RFC-1212OBJECT-TYPE
RFC1155-SMICounter enterprises
OIDNameAccessStatusDescription
1.3.6.1.4.1.272Nodebintec
1.3.6.1.4.1.272.4Nodebibo
1.3.6.1.4.1.272.4.25Nodeserial
1.3.6.1.4.1.272.4.25.1TableserialIfTablenot-accessiblemandatoryThe serialIfTable contains information relating to the interfaces available on the system. Each entry corresponds to an available serial interface. Entries can…
1.3.6.1.4.1.272.4.25.1.1RowserialIfEntrynot-accessiblemandatory
1.3.6.1.4.1.272.4.25.1.1.1ColumnserialIfIndexread-onlymandatoryUnique interface index of the serial interface.
1.3.6.1.4.1.272.4.25.1.1.2ColumnserialIfTyperead-writemandatoryThe serial physical interface type none(1) interface disabled x21(2) X21(V11) terminated (sync) v35(3) V35(V11 & V28) (sync) v36(4) V36(V10 & V11) (sync) x21bi…
1.3.6.1.4.1.272.4.25.1.1.3ColumnserialIfConnectorread-writemandatoryThe physical connector type. When configured as DCE the pins on the output connector act as a DCE interface. If configured as DTE on the output connector act a…
1.3.6.1.4.1.272.4.25.1.1.4ColumnserialIfLeadsread-writemandatoryThe value of IfLeads has influence on the state of the physical layer (L1State). When configured as IfLeads=enabled, the state of the physical layer depends on…
1.3.6.1.4.1.272.4.25.1.1.5ColumnserialIfClockread-writemandatoryThe physical layer (layer 1) clocking mode. When configured as AUTO the clock provided depends what is configured on connector. If connector is configured as D…
1.3.6.1.4.1.272.4.25.1.1.6ColumnserialIfClockEdgeread-writemandatoryThe value of IfClockEdge influences the (internal) active clock edge(s) for generating/sampling data on the serial line. This value should be left on DEFAULT u…
1.3.6.1.4.1.272.4.25.1.1.8ColumnserialIfSpeedread-writemandatoryThe serial interface speed in bits per second. The range is dependant on the type of the line (balanced/unbalanced) and the quality and length of the cable. Ov…
1.3.6.1.4.1.272.4.25.1.1.10ColumnserialIfL2Moderead-writemandatoryThe layer 2 mode. This value has influence on the HDLC address field (first byte of a HDCL frame). When configured as DTE the address in a command frame is 0x0…
1.3.6.1.4.1.272.4.25.1.1.11ColumnserialIfCableDetectionread-writemandatoryCable autodetection for: manual(1) disabled auto(2) serialIfType and serialIfConnector iftype(3) serialIfType connector(4) serialIfConnector
1.3.6.1.4.1.272.4.25.1.1.12ColumnserialIfCableTyperead-onlymandatoryShow the detected cable type: unknown(1) cable type unknown. x21(2) DB15, X27/V11 (sync) v35(3) M34, V35/V10 (sync) v36(4) DB37, V10/V11 (sync) x21bis(5) DB25,…
1.3.6.1.4.1.272.4.25.1.1.13ColumnserialIfCableConnectorread-onlymandatoryShow the detected cable connector type: dte(1) DTE cable dce(2) DCE cable unknown(3) cable type unknown. not-supported(4) cable detection not supported.
1.3.6.1.4.1.272.4.25.1.1.14ColumnserialIfBundleread-writemandatoryIndex of the bundle to aggregate multiple Channels to one interface.
1.3.6.1.4.1.272.4.25.1.1.15ColumnserialIfL1Stateread-onlymandatoryThe serial physical layer state dn(1) physical layer is inactive up(2) physical layer is active
1.3.6.1.4.1.272.4.25.1.1.16ColumnserialIfSpeedRealread-onlymandatoryIn DCE/internal clock mode this is the rounded speed in bits per second, because not every baudrate can exactly be generated. In DTE/external clock mode this i…
1.3.6.1.4.1.272.4.25.1.1.17ColumnserialIfLicenseread-onlymandatoryShows wether a serial license associated with this serial port port is required, missing or in use.
1.3.6.1.4.1.272.4.25.1.1.20ColumnserialIfRxPacketsread-onlymandatoryCount of received valid Frames.
1.3.6.1.4.1.272.4.25.1.1.21ColumnserialIfRxOctetsread-onlymandatoryCount of received bytes.
1.3.6.1.4.1.272.4.25.1.1.22ColumnserialIfTxPacketsread-onlymandatoryCount of transmitted valid Frames.
1.3.6.1.4.1.272.4.25.1.1.23ColumnserialIfTxOctetsread-onlymandatoryCount of transmitted bytes.
1.3.6.1.4.1.272.4.25.1.1.24ColumnserialIfRxResetsread-onlymandatoryCount of receiver resets. Under rare circumstances it might be necessary to reset the receiver to work properly.
1.3.6.1.4.1.272.4.25.1.1.25ColumnserialIfRxAbortsread-onlymandatoryCount of receiver aborts. The sender of a frame can indicate a frame as aborted with a special Abort sequence.
1.3.6.1.4.1.272.4.25.1.1.26ColumnserialIfRxOverrunsread-onlymandatoryCount of receiver overruns. If the serial port is unable to grant sufficiently soon/often the bus, the RxFIFO may fill up. This leads to loss of data.
1.3.6.1.4.1.272.4.25.1.1.27ColumnserialIfRxCRCErrorsread-onlymandatoryCount of corrupted frames. Errors due to interference on the serial cable.
1.3.6.1.4.1.272.4.25.1.1.28ColumnserialIfRxGiantFramesread-onlymandatoryCount of received frames with illegal framesize. This can occur if a frame delimiter is destroyed.
1.3.6.1.4.1.272.4.25.1.1.29ColumnserialIfTxResetsread-onlymandatoryCount of transmitter resets. Under rare circumstances it might be necessary to reset the transmitter to work properly.
1.3.6.1.4.1.272.4.25.1.1.30ColumnserialIfTxAbortsread-onlymandatoryCount of transmitter aborts. While sending a frame it might be necessary to indicate this frame as aborted. In this case the receiver regards this frame as ill…
1.3.6.1.4.1.272.4.25.1.1.31ColumnserialIfTxUnderrunsread-onlymandatoryCount of transmitter underruns. The serial data for the serial port is supplied too slowly.
1.3.6.1.4.1.272.4.25.1.1.32ColumnserialIfTxGiantFramesread-onlymandatoryCount of transmitted frames with illegal framesize. This can occur if an upper module creates packets with more than the maximum allowed packet size.