16 objects
MIB module for ethernet (or the like) phy specific definitions.
Imported Objects
| BINTEC-MIB MISSING | Date HexValue phy |
| RFC-1215 | TRAP-TYPE |
| SNMPv2-SMI | Counter32 Counter64 enterprises Gauge32 Integer32 IpAddress mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DisplayString PhysAddress TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.12124.250.50.7.1 | TableethPhyTable | not-accessible | current | The ethPhyTable contains information relating to the interfaces available on the system. Each entry corresponds to an available ethernet or switch port. Entrie… |
| 1.3.6.1.4.1.12124.250.50.7.1.1 | RowethPhyEntry | not-accessible | current | The ethPhyEntry contains configuration and status information of a physical interface associated to one ethernet interface. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.1 | ColumnethPhyPortIndex | read-only | current | The unique ethernet PHY interface index. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.2 | ColumnethPhyChipVendor | read-only | current | The vendor name or identifier of the PHY or switch detected during hardware scan. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.3 | ColumnethPhyChipModel | read-only | current | The chip modell/revision of the PHY or switch detected during hardware scan. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.6 | ColumnethPhyPortLinkStatus | read-only | current | This variable indicates link status and autonegotiation results: down(1) auto-neg-failed(2) auto-neg-unavail(3) auto-neg-running(4) auto-full-100(5) auto-half-… |
| 1.3.6.1.4.1.12124.250.50.7.1.1.7 | ColumnethPhyPortMdixStatus | read-only | current | This variable indicates the cables MDIX status if the link is established. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.9 | ColumnethPhyPortCapabilities | read-only | current | This bitfield describes what modes the port supports: half-10 : 10Mbit/s half duplex full-10 : 10Mbit/s full duplex half-100 : 100Mbit/s half duplex full-100 :… |
| 1.3.6.1.4.1.12124.250.50.7.1.1.10 | ColumnethPhyPortMode | read-write | current | The initial mode of the ethernet PHY or switch port: disable(1) auto(2) auto-100(3) auto-10(4) auto-full-100(5) auto-half-100(6) auto-full-10(7) auto-half-10(8… |
| 1.3.6.1.4.1.12124.250.50.7.1.1.12 | ColumnethPhyEthAssignedIfIndex | read-write | obsolete | The Ethernet interface index the PHY or switch port is connected/assigned to. The system will create interfaces as needed, but there can't be more ethernet int… |
| 1.3.6.1.4.1.12124.250.50.7.1.1.13 | ColumnethPhyExtendedDistance | read-write | current | If the PHY supports different receive thresholds depending on the cable length (long-cable > 100 m) and speed (10BaseT) it could be configured by this variable. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.18 | ColumnethPhyPortGroup | read-write | current | The port group this phy is member of. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.21 | ColumnethPhyPortDescr | read-write | current | This object is available to the user for specifying a user-friendly name or tag. |
| 1.3.6.1.4.1.12124.250.50.7.1.1.22 | ColumnethPhyPortFlowControl | read-write | current | If the PHY supports flow control according to IEEE 802.3x flow control can be enabled on that port by setting variable to value 'auto'. This will cause 802.3x … |
| 1.3.6.1.4.1.12124.250.50.7.1.1.23 | ColumnethPhyPortFlowControlStatus | read-only | current | This variable indicates whether flow control according to IEEE 802.3x is currently active on that port. Possible values are ... disabled(1) and enabled(2) |