MIB Viewer

BIANCA-X8000-MIBSYS-MIB

32 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMICounter enterprises
RFC1158-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.272Nodebintec
1.3.6.1.4.1.272.4Nodebibo
1.3.6.1.4.1.272.4.17Nodesys
1.3.6.1.4.1.272.4.17.3Nodex8
1.3.6.1.4.1.272.4.17.3.1NodesysX8Config
1.3.6.1.4.1.272.4.17.3.1.1ScalarsysX8ConfigPowerSupply1Stateread-onlymandatoryThis variable shows the state of the power supply.
1.3.6.1.4.1.272.4.17.3.1.2ScalarsysX8ConfigPowerSupply1Tempread-onlymandatoryThis variable shows the actual power supply temperature in the unit Celsius.
1.3.6.1.4.1.272.4.17.3.1.3ScalarsysX8ConfigPowerSupply1TempAlarmThresholdread-writemandatoryPower supply 1 temperature threshold.
1.3.6.1.4.1.272.4.17.3.1.4ScalarsysX8ConfigPowerSupply1TempAlarmTrapread-onlymandatoryIf the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds.
1.3.6.1.4.1.272.4.17.3.1.5ScalarsysX8ConfigPowerSupply2Stateread-onlymandatoryThis variable show the the state of the power supply.
1.3.6.1.4.1.272.4.17.3.1.6ScalarsysX8ConfigPowerSupply2Tempread-onlymandatoryThis variable shows the actual power supply temperature in the unit Celsius.
1.3.6.1.4.1.272.4.17.3.1.7ScalarsysX8ConfigPowerSupply2TempAlarmThresholdread-writemandatoryPower supply 2 temperature threshold.
1.3.6.1.4.1.272.4.17.3.1.8ScalarsysX8ConfigPowerSupply2TempAlarmTrapread-onlymandatoryIf the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds.
1.3.6.1.4.1.272.4.17.3.1.9ScalarsysX8ConfigFanControlread-writemandatoryThis variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans r…
1.3.6.1.4.1.272.4.17.3.1.10ScalarsysX8ConfigFanVersionread-onlymandatoryThis variable shows the firmware version of the fan unit.
1.3.6.1.4.1.272.4.17.3.1.11ScalarsysX8ConfigFan1read-onlymandatoryThis variable shows the current turning speed.
1.3.6.1.4.1.272.4.17.3.1.12ScalarsysX8ConfigFan2read-onlymandatoryThis variable shows the current turning speed.
1.3.6.1.4.1.272.4.17.3.1.13ScalarsysX8ConfigFan3read-onlymandatoryThis variable shows the current turning speed.
1.3.6.1.4.1.272.4.17.3.1.14ScalarsysX8ConfigFan4read-onlymandatoryThis variable shows the current turning speed.
1.3.6.1.4.1.272.4.17.3.2NodesysX8Traps
1.3.6.1.4.1.272.4.17.3.2.1NodesysX8TrapPowerSupply1MissingThis trap signifies that the power supply 1 has been removed
1.3.6.1.4.1.272.4.17.3.2.2NodesysX8TrapPowerSupply1PowerOffThis trap signifies that the power supply 1 has no power-good signal (no power input)
1.3.6.1.4.1.272.4.17.3.2.3NodesysX8TrapPowerSupply1PowerFailThis trap signifies that the power supply 1 has been in the failure (bad DC output)
1.3.6.1.4.1.272.4.17.3.2.4NodesysX8TrapPowerSupply1PowerGoodThis trap signifies that the power supply 1 is running (supplying power)
1.3.6.1.4.1.272.4.17.3.2.5NodesysX8TrapPowerSupply1TempCriticalThis trap signifies that the power supply 1 temperature raises above the critical alarm-threshold
1.3.6.1.4.1.272.4.17.3.2.6NodesysX8TrapPowerSupply1TempOkA normal power supply 1 temperature has been restored.
1.3.6.1.4.1.272.4.17.3.2.7NodesysX8TrapPowerSupply2MissingThis trap signifies that the power supply 2 has been removed
1.3.6.1.4.1.272.4.17.3.2.8NodesysX8TrapPowerSupply2PowerOffThis trap signifies that the power supply 2 has no power-good signal (no power input)
1.3.6.1.4.1.272.4.17.3.2.9NodesysX8TrapPowerSupply2PowerFailThis trap signifies that the power supply 2 has been in the failure (bad DC output)
1.3.6.1.4.1.272.4.17.3.2.10NodesysX8TrapPowerSupply2PowerGoodThis trap signifies that the power supply 2 is running (supplying power)
1.3.6.1.4.1.272.4.17.3.2.11NodesysX8TrapPowerSupply2TempCriticalThis trap signifies that the power supply 2 temperature raises above the critical alarm-threshold
1.3.6.1.4.1.272.4.17.3.2.12NodesysX8TrapPowerSupply2TempOkA normal power supply 2 temperature has been restored.