BIANCA-X8000-MIBSYS-MIB
32 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises |
| RFC1158-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.272 | Nodebintec | |||
| 1.3.6.1.4.1.272.4 | Nodebibo | |||
| 1.3.6.1.4.1.272.4.17 | Nodesys | |||
| 1.3.6.1.4.1.272.4.17.3 | Nodex8 | |||
| 1.3.6.1.4.1.272.4.17.3.1 | NodesysX8Config | |||
| 1.3.6.1.4.1.272.4.17.3.1.1 | ScalarsysX8ConfigPowerSupply1State | read-only | mandatory | This variable shows the state of the power supply. |
| 1.3.6.1.4.1.272.4.17.3.1.2 | ScalarsysX8ConfigPowerSupply1Temp | read-only | mandatory | This variable shows the actual power supply temperature in the unit Celsius. |
| 1.3.6.1.4.1.272.4.17.3.1.3 | ScalarsysX8ConfigPowerSupply1TempAlarmThreshold | read-write | mandatory | Power supply 1 temperature threshold. |
| 1.3.6.1.4.1.272.4.17.3.1.4 | ScalarsysX8ConfigPowerSupply1TempAlarmTrap | read-only | mandatory | If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds. |
| 1.3.6.1.4.1.272.4.17.3.1.5 | ScalarsysX8ConfigPowerSupply2State | read-only | mandatory | This variable show the the state of the power supply. |
| 1.3.6.1.4.1.272.4.17.3.1.6 | ScalarsysX8ConfigPowerSupply2Temp | read-only | mandatory | This variable shows the actual power supply temperature in the unit Celsius. |
| 1.3.6.1.4.1.272.4.17.3.1.7 | ScalarsysX8ConfigPowerSupply2TempAlarmThreshold | read-write | mandatory | Power supply 2 temperature threshold. |
| 1.3.6.1.4.1.272.4.17.3.1.8 | ScalarsysX8ConfigPowerSupply2TempAlarmTrap | read-only | mandatory | If the power supply temperature raises above the threshold, a alarm trap is generated every 60 seconds. |
| 1.3.6.1.4.1.272.4.17.3.1.9 | ScalarsysX8ConfigFanControl | read-write | mandatory | This variable defines automatic fan control. In mode 'auto' the fans are automatically adjusted depending on the current temperature. In mode 'high' all fans r… |
| 1.3.6.1.4.1.272.4.17.3.1.10 | ScalarsysX8ConfigFanVersion | read-only | mandatory | This variable shows the firmware version of the fan unit. |
| 1.3.6.1.4.1.272.4.17.3.1.11 | ScalarsysX8ConfigFan1 | read-only | mandatory | This variable shows the current turning speed. |
| 1.3.6.1.4.1.272.4.17.3.1.12 | ScalarsysX8ConfigFan2 | read-only | mandatory | This variable shows the current turning speed. |
| 1.3.6.1.4.1.272.4.17.3.1.13 | ScalarsysX8ConfigFan3 | read-only | mandatory | This variable shows the current turning speed. |
| 1.3.6.1.4.1.272.4.17.3.1.14 | ScalarsysX8ConfigFan4 | read-only | mandatory | This variable shows the current turning speed. |
| 1.3.6.1.4.1.272.4.17.3.2 | NodesysX8Traps | |||
| 1.3.6.1.4.1.272.4.17.3.2.1 | NodesysX8TrapPowerSupply1Missing | This trap signifies that the power supply 1 has been removed | ||
| 1.3.6.1.4.1.272.4.17.3.2.2 | NodesysX8TrapPowerSupply1PowerOff | This trap signifies that the power supply 1 has no power-good signal (no power input) | ||
| 1.3.6.1.4.1.272.4.17.3.2.3 | NodesysX8TrapPowerSupply1PowerFail | This trap signifies that the power supply 1 has been in the failure (bad DC output) | ||
| 1.3.6.1.4.1.272.4.17.3.2.4 | NodesysX8TrapPowerSupply1PowerGood | This trap signifies that the power supply 1 is running (supplying power) | ||
| 1.3.6.1.4.1.272.4.17.3.2.5 | NodesysX8TrapPowerSupply1TempCritical | This trap signifies that the power supply 1 temperature raises above the critical alarm-threshold | ||
| 1.3.6.1.4.1.272.4.17.3.2.6 | NodesysX8TrapPowerSupply1TempOk | A normal power supply 1 temperature has been restored. | ||
| 1.3.6.1.4.1.272.4.17.3.2.7 | NodesysX8TrapPowerSupply2Missing | This trap signifies that the power supply 2 has been removed | ||
| 1.3.6.1.4.1.272.4.17.3.2.8 | NodesysX8TrapPowerSupply2PowerOff | This trap signifies that the power supply 2 has no power-good signal (no power input) | ||
| 1.3.6.1.4.1.272.4.17.3.2.9 | NodesysX8TrapPowerSupply2PowerFail | This trap signifies that the power supply 2 has been in the failure (bad DC output) | ||
| 1.3.6.1.4.1.272.4.17.3.2.10 | NodesysX8TrapPowerSupply2PowerGood | This trap signifies that the power supply 2 is running (supplying power) | ||
| 1.3.6.1.4.1.272.4.17.3.2.11 | NodesysX8TrapPowerSupply2TempCritical | This trap signifies that the power supply 2 temperature raises above the critical alarm-threshold | ||
| 1.3.6.1.4.1.272.4.17.3.2.12 | NodesysX8TrapPowerSupply2TempOk | A normal power supply 2 temperature has been restored. |