BINTEC-POTS-MIB
101 objects
The MIB module for POTS interface administration entities.
Imported Objects
| BINTEC-MIB MISSING | bibo BitValue Date HexValue |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Counter64 enterprises Integer32 IpAddress mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DisplayString TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.272.4.14 | IdentitypotsMIB | The MIB module for POTS interface administration entities. | ||
| 1.3.6.1.4.1.272.4.14.1 | Nodepots | |||
| 1.3.6.1.4.1.272.4.14.1.1 | TablepotsIfTable | not-accessible | current | The potsIfTable contains configuration information for the POTS outlets. |
| 1.3.6.1.4.1.272.4.14.1.1.1 | RowpotsIfEntry | not-accessible | current | |
| 1.3.6.1.4.1.272.4.14.1.1.1.1 | ColumnpotsSlot | read-only | current | Identification number of the used slot. |
| 1.3.6.1.4.1.272.4.14.1.1.1.2 | ColumnpotsUnit | read-only | current | Identification number of the used unit. |
| 1.3.6.1.4.1.272.4.14.1.1.1.3 | ColumnpotsType | read-write | current | The type of the connected device on socket a. Possible values are: - any(1), (multifunctional) - fax(2), - telephony(3), - modem(4), - disable(5), - doorinterc… |
| 1.3.6.1.4.1.272.4.14.1.1.1.4 | ColumnpotsIfMode | read-only | current | Type of outlet. |
| 1.3.6.1.4.1.272.4.14.1.1.1.5 | ColumnpotsIfAdminState | read-write | current | This variable allows for taking an POTS interface out of/in service w/o having to touch the configuration. Besides, it is possible to initiate a reconfiguratio… |
| 1.3.6.1.4.1.272.4.14.1.1.1.6 | ColumnpotsIfOperState | read-only | current | The operational state of an interface is indicated via this variable. Possible values are: - down(1), - running(2), - fail(3), - not-connected(4), - stopped(5)… |
| 1.3.6.1.4.1.272.4.14.1.1.1.7 | ColumnpotsIfIndex | read-only | current | Reference to the FXS or FXO table. |
| 1.3.6.1.4.1.272.4.14.1.1.1.8 | ColumnpotsIfTtxLevel | read-write | current | Teletax (metering pulse) level: for FXS lines: output level for FXO lines: minimum level |
| 1.3.6.1.4.1.272.4.14.1.1.1.9 | ColumnpotsIfTtxFreq | read-write | current | Teletax (metering pulse) frequency: 1: no teletax output/reception 3: 12 kHz 4: 16 kHz |
| 1.3.6.1.4.1.272.4.14.1.1.1.10 | ColumnpotsIfCoeffIndex | read-write | current | Selection of the coefficient set provided by the FXS or FXO line driver. This allows to use specific settings with e.g. resistive or complex line impedances. S… |
| 1.3.6.1.4.1.272.4.14.1.1.1.11 | ColumnpotsIfTxGain | read-write | current | Amplification or attenuation (negative gain) of outgoing audio in dB. |
| 1.3.6.1.4.1.272.4.14.1.1.1.12 | ColumnpotsIfRxGain | read-write | current | Amplification or attenuation (negative gain) of incoming audio in dB. |
| 1.3.6.1.4.1.272.4.14.1.1.1.13 | ColumnpotsIfDialInTimeout | read-write | current | Limit for time interval between two consecutive dialling digits. |
| 1.3.6.1.4.1.272.4.14.1.2 | TablepotsIfFxoTable | read-write | current | The potsIfFxoTable contains configuration information for the FXO outlets. |
| 1.3.6.1.4.1.272.4.14.1.2.1 | RowpotsIfFxoEntry | not-accessible | current | |
| 1.3.6.1.4.1.272.4.14.1.2.1.1 | ColumnpotsIfFxoIfIndex | read-write | current | Index of the FXO interface. |
| 1.3.6.1.4.1.272.4.14.1.2.1.2 | ColumnpotsIfFxoFlashTime | read-write | current | Dial out flash time (ms). |
| 1.3.6.1.4.1.272.4.14.1.2.1.3 | ColumnpotsIfFxoDialToneDetection | read-write | obsolete | Type of tone: off(1) no dial tone detection single(2) detect just one tone rhythm dual(3) detect also an alternative tone rhythm Enable dial tone detection. Th… |
| 1.3.6.1.4.1.272.4.14.1.2.1.4 | ColumnpotsIfFxoDialToneDetectionTime | read-write | obsolete | Activation time for dial tone detection in seconds. When this time is reached dial tone detection will be switched off. A zero value keeps dial tone detection … |
| 1.3.6.1.4.1.272.4.14.1.2.1.5 | ColumnpotsIfFxoDialToneMinLevel | read-write | obsolete | minimum dial tone level. |
| 1.3.6.1.4.1.272.4.14.1.2.1.6 | ColumnpotsIfFxoDialToneOrgFreq | read-write | obsolete | Frequency of the expected dial tone (Hz). |
| 1.3.6.1.4.1.272.4.14.1.2.1.7 | ColumnpotsIfFxoDialToneOrgCadence | read-write | obsolete | Cadence of the expected dial tone. The cadence definition consists of times of activity, times of no activity and some control information. All information is … |
| 1.3.6.1.4.1.272.4.14.1.2.1.8 | ColumnpotsIfFxoDialToneOrgTolerance | read-write | obsolete | Dial tone timing tolerance (%). |
| 1.3.6.1.4.1.272.4.14.1.2.1.9 | ColumnpotsIfFxoDialToneAltFreq | read-write | obsolete | Alternative dial tone frequncy (Hz). |
| 1.3.6.1.4.1.272.4.14.1.2.1.10 | ColumnpotsIfFxoDialToneAltCadence | read-write | obsolete | Alternative dial tone cadence. For a description of allowed format refer to potsIfFxoDialToneOrgCadence. |
| 1.3.6.1.4.1.272.4.14.1.2.1.11 | ColumnpotsIfFxoDialToneAltTolerance | read-write | obsolete | Alternative dial tone timing tolerance (%). |
| 1.3.6.1.4.1.272.4.14.1.2.1.12 | ColumnpotsIfFxoBusyToneDetection | read-write | obsolete | Type of tone: off(1) no busy tone detection single(2) detect just one tone rhythm dual(3) detect also an alternative tone rhythm Enable busy tone detection. |
| 1.3.6.1.4.1.272.4.14.1.2.1.13 | ColumnpotsIfFxoBusyToneDetectionTime | read-write | obsolete | Activation time for busy tone detection in seconds. When this time is reached busy tone detection will be switched off. A zero value keeps busy tone detection … |
| 1.3.6.1.4.1.272.4.14.1.2.1.14 | ColumnpotsIfFxoBusyToneMinLevel | read-write | obsolete | Minimum busy tone level (dB). |
| 1.3.6.1.4.1.272.4.14.1.2.1.15 | ColumnpotsIfFxoBusyToneOrgFreq | read-write | obsolete | Busy tone frequncy (Hz). |
| 1.3.6.1.4.1.272.4.14.1.2.1.16 | ColumnpotsIfFxoBusyToneOrgCadence | read-write | obsolete | Busy tone cadence. For a description of allowed format refer to potsIfFxoDialToneOrgCadence. |
| 1.3.6.1.4.1.272.4.14.1.2.1.17 | ColumnpotsIfFxoBusyToneOrgTolerance | read-write | obsolete | Busy tone timing tolerance (%). |
| 1.3.6.1.4.1.272.4.14.1.2.1.18 | ColumnpotsIfFxoBusyToneAltFreq | read-write | obsolete | Alternative busy tone frequncy. |
| 1.3.6.1.4.1.272.4.14.1.2.1.19 | ColumnpotsIfFxoBusyToneAltCadence | read-write | obsolete | Alternative busy tone cadence. For a description of allowed format refer to potsIfFxoDialToneOrgCadence. |
| 1.3.6.1.4.1.272.4.14.1.2.1.20 | ColumnpotsIfFxoBusyToneAltTolerance | read-write | obsolete | Alternative busy tone timing tolerance (%). |
| 1.3.6.1.4.1.272.4.14.1.2.1.21 | ColumnpotsIfFxoDialOutMode | read-write | current | Dial-out mode (1: pulse, 2: DTMF). |
| 1.3.6.1.4.1.272.4.14.1.2.1.22 | ColumnpotsIfFxoDialOutDelay | read-write | current | Waiting time before dialout starts (ms). |
| 1.3.6.1.4.1.272.4.14.1.2.1.23 | ColumnpotsIfFxoDialInMode | read-write | current | Dial-in mode (1: off, 2: DTMF, 3: UEFS). |
| 1.3.6.1.4.1.272.4.14.1.2.1.24 | ColumnpotsIfFxoDialInProgressTone | read-write | current | The progress tone is used for dial in mode 'DTMF' only. Other dial in modes will ignore this entry. The progress tone will signal the caller when to start to d… |
| 1.3.6.1.4.1.272.4.14.1.2.1.25 | ColumnpotsIfFxoDialInProgressToneDef | read-write | current | Index of the progress tone definition in phoneIfToneTable. |
| 1.3.6.1.4.1.272.4.14.1.2.1.26 | ColumnpotsIfFxoDialPulsePulseTime | read-write | current | Pulse dialling break time (ms). |
| 1.3.6.1.4.1.272.4.14.1.2.1.27 | ColumnpotsIfFxoDialPulsePauseTime | read-write | current | Pulse dialling make time (ms). |
| 1.3.6.1.4.1.272.4.14.1.2.1.28 | ColumnpotsIfFxoDialPulseInterDigitTime | read-write | current | DTMF dialling interdigit time (ms). |
| 1.3.6.1.4.1.272.4.14.1.2.1.29 | ColumnpotsIfFxoDialDtmfLevel | read-write | current | DTMF tone level (dB). |
| 1.3.6.1.4.1.272.4.14.1.2.1.30 | ColumnpotsIfFxoDialDtmfToneTime | read-write | current | DTMF tone duration (ms). |
| 1.3.6.1.4.1.272.4.14.1.2.1.31 | ColumnpotsIfFxoDialDtmfInterDigitTime | read-write | current | DTMF dialling interdigit time (ms). |
| 1.3.6.1.4.1.272.4.14.1.2.1.32 | ColumnpotsIfFxoDataLinkMinLevel | read-write | current | Minimum data transmission level (dB). |
| 1.3.6.1.4.1.272.4.14.1.2.1.33 | ColumnpotsIfFxoDataLinkModeOnHook | read-write | current | Allowed on-hook data transmission modes: dt-as: data transmission prior to ringing with DT-AS dt-as-pol-rev: data transmission prior to ringing with DT-AS and … |
| 1.3.6.1.4.1.272.4.14.1.2.1.34 | ColumnpotsIfFxoDataLinkModeOffHook | read-write | current | Selection of off-hook data transmission mode: 1: no off-hook data transmission 2: data transmission prior using DT-AS |
| 1.3.6.1.4.1.272.4.14.1.2.1.35 | ColumnpotsIfFxoFaxToneDetection | read-write | current | Fax tone detection. Tones to detect according to ITU T.30: cng: fax announce tone 1100 Hz ced: fax answer tone 2100 Hz dis: digital identification signal V.21 |
| 1.3.6.1.4.1.272.4.14.1.2.1.36 | ColumnpotsIfFxoKeyBreakDetection | read-write | current | Detection of key break as a release condition. |
| 1.3.6.1.4.1.272.4.14.1.2.1.37 | ColumnpotsIfFxoDialOutToneDetection | read-write | current | Detection of dial tones as a trigger for outgoing dial. |
| 1.3.6.1.4.1.272.4.14.1.2.1.38 | ColumnpotsIfFxoNormalDialTone | read-write | current | Index of the normal dial tone definition in phoneIfToneTable used by dial out tone detection. |
| 1.3.6.1.4.1.272.4.14.1.2.1.39 | ColumnpotsIfFxoSpecialDialTone | read-write | current | Index of the special dial tone definition in phoneIfToneTable used by dial out tone detection. |
| 1.3.6.1.4.1.272.4.14.1.2.1.40 | ColumnpotsIfFxoConcurrentToneDetection | read-write | current | Detection of tones after dialling and during a connection to catch a release condition. |
| 1.3.6.1.4.1.272.4.14.1.2.1.41 | ColumnpotsIfFxoBusyTone | read-write | current | Index of the busy tone definition in phoneIfToneTable used by concurrent tone detection. |
| 1.3.6.1.4.1.272.4.14.1.2.1.42 | ColumnpotsIfFxoCongestionTone | read-write | current | Index of the congestion tone definition in phoneIfToneTable used by concurrent tone detection. |
| 1.3.6.1.4.1.272.4.14.1.3 | TablepotsIfFxsTable | read-write | current | The potsIfFxsTable contains configuration information for the FXS outlets. |
| 1.3.6.1.4.1.272.4.14.1.3.1 | RowpotsIfFxsEntry | not-accessible | current | |
| 1.3.6.1.4.1.272.4.14.1.3.1.1 | ColumnpotsIfFxsIfIndex | read-write | current | Index of the FXS interface. |
| 1.3.6.1.4.1.272.4.14.1.3.1.2 | ColumnpotsIfFxsFlashMinTime | read-write | current | Minimum flash duration (ms). Flash pulses below this value will be ignored. |
| 1.3.6.1.4.1.272.4.14.1.3.1.3 | ColumnpotsIfFxsFlashMaxTime | read-write | current | Maximum flash duration (ms). Flash pulses above this value will be interpreted as hook-on. |
| 1.3.6.1.4.1.272.4.14.1.3.1.4 | ColumnpotsIfFxsRingLevel | read-write | current | Peak value of sinusoidal ringing voltage. |
| 1.3.6.1.4.1.272.4.14.1.3.1.5 | ColumnpotsIfFxsRingFreq | read-write | current | Frequency of sinusoidal ringing voltage. |
| 1.3.6.1.4.1.272.4.14.1.3.1.6 | ColumnpotsIfFxsRingTableIndex | read-write | current | The ringing table index is the reference to all ringing cadences used for this extension. Definitions are in phoneIfRingTable. |
| 1.3.6.1.4.1.272.4.14.1.3.1.7 | ColumnpotsIfFxsToneTableIndex | read-write | current | The tone table index refers to the tones used for this extension. Definitions are in phoneIfToneTable |
| 1.3.6.1.4.1.272.4.14.1.3.1.8 | ColumnpotsIfFxsDataLinkType | read-write | current | Allowed data transmission message types: setup - call setup message mwi - message waiting indicator message aoc - advice of charge message sms - short message … |
| 1.3.6.1.4.1.272.4.14.1.3.1.9 | ColumnpotsIfFxsDataLinkElem | read-write | current | Allowed data transmission parameters (see ETSI EN 300 659-3). Not selected elements will be filtered out and not sent to the subscriber. |
| 1.3.6.1.4.1.272.4.14.1.3.1.10 | ColumnpotsIfFxsDataLinkLevel | read-write | current | Level of the data transmission signal (dB). |
| 1.3.6.1.4.1.272.4.14.1.3.1.11 | ColumnpotsIfFxsDataLinkTiming | read-write | current | Index of the timer set to be used for on-hook and off-hook data transmission. |
| 1.3.6.1.4.1.272.4.14.1.3.1.12 | ColumnpotsIfFxsDataLinkModeOnHook | read-write | current | Selection of on-hook data transmission mode: 1: no on-hook data transmission 2: data transmission prior to ringing with DT-AS 3: data transmission prior to rin… |
| 1.3.6.1.4.1.272.4.14.1.3.1.13 | ColumnpotsIfFxsDataLinkModeOffHook | read-write | current | Selection of off-hook data transmission mode: 1: no off-hook data transmission 2: data transmission prior using DT-AS |
| 1.3.6.1.4.1.272.4.14.1.3.1.14 | ColumnpotsIfFxsDialPulseMinTimePulse | read-write | current | Pulse dialling break time minimum (ms). Break pulses below this limit will be ignored. |
| 1.3.6.1.4.1.272.4.14.1.3.1.15 | ColumnpotsIfFxsDialPulseMaxTimePulse | read-write | current | Pulse dialling break time maximum (ms). A pause time above this limit is regarded as on-hook signal. |
| 1.3.6.1.4.1.272.4.14.1.3.1.16 | ColumnpotsIfFxsDialPulseMinTimePause | read-write | current | Pulse dialling make time minimum (ms). Make pulses below this limit will be ignored. |
| 1.3.6.1.4.1.272.4.14.1.3.1.17 | ColumnpotsIfFxsDialPulseMaxTimePause | read-write | current | Pulse dialling make time maximum (ms). A pause time above this limit finishes the pulse counting and this digit is regarded as complete. |
| 1.3.6.1.4.1.272.4.14.1.4 | TablepotsIfDataLinkTimerTable | read-write | current | The potsIfDataLinkTimerTable the contains timer values (in ms) controlling on-hook and off-hook data transmission service according to ETSI EN 300 659. The rec… |
| 1.3.6.1.4.1.272.4.14.1.4.1 | RowpotsIfDataLinkTimerEntry | read-write | current | |
| 1.3.6.1.4.1.272.4.14.1.4.1.1 | ColumnpotsIfDataLinkTimerIndex | read-write | current | Index of the set of timers which is following up. |
| 1.3.6.1.4.1.272.4.14.1.4.1.2 | ColumnpotsIfDataLinkTimer0 | read-write | current | Timer T0 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.3 | ColumnpotsIfDataLinkTimer1 | read-write | current | Timer T1 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.4 | ColumnpotsIfDataLinkTimer2 | read-write | current | Timer T2 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.5 | ColumnpotsIfDataLinkTimer3 | read-write | current | Timer T3 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.6 | ColumnpotsIfDataLinkTimer4 | read-write | current | Timer T4 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.7 | ColumnpotsIfDataLinkTimer5 | read-write | current | Timer T5 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.8 | ColumnpotsIfDataLinkTimer6 | read-write | current | Timer T6 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.9 | ColumnpotsIfDataLinkTimer7 | read-write | current | Timer T7 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.10 | ColumnpotsIfDataLinkTimer8 | read-write | current | Timer T8 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.11 | ColumnpotsIfDataLinkTimer9 | read-write | current | Timer T9 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.12 | ColumnpotsIfDataLinkTimer10 | read-write | current | Timer T10 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.13 | ColumnpotsIfDataLinkTimer11 | read-write | current | Timer T11 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.14 | ColumnpotsIfDataLinkTimer12 | read-write | current | Timer T12 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.15 | ColumnpotsIfDataLinkTimer13 | read-write | current | Timer T13 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.16 | ColumnpotsIfDataLinkTimer14 | read-write | current | Timer T14 according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.17 | ColumnpotsIfDataLinkTimerRpAs | read-write | current | Timer RP-AS according to ETSI EN 300 659. |
| 1.3.6.1.4.1.272.4.14.1.4.1.18 | ColumnpotsIfDataLinkTimerDtAsOnH | read-write | current | Timer DT-AS on-hook according to ETSI EN 300 659. |