MIB Viewer

BLADE-MIB

2882 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.3NodeibmAgents
1.3.6.1.4.1.2.3.51NodenetfinitySupportProcessorAgent
1.3.6.1.4.1.2.3.51.2NodebladeCenterSnmpMIB
1.3.6.1.4.1.2.3.51.2.2Nodemonitors
1.3.6.1.4.1.2.3.51.2.2.1Nodetemperature
1.3.6.1.4.1.2.3.51.2.2.1.1NodeplanarTemp
1.3.6.1.4.1.2.3.51.2.2.1.1.2ScalarmmTempread-onlymandatoryManagement module temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space…
1.3.6.1.4.1.2.3.51.2.2.1.5NodeambientTemp
1.3.6.1.4.1.2.3.51.2.2.1.5.1ScalarfrontPanelTempread-onlymandatoryThe front panel temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Cent…
1.3.6.1.4.1.2.3.51.2.2.1.5.2ScalarfrontPanel2Tempread-onlymandatoryThe front panel 2 temperature in degrees centigrade(C). This is surrounding temperature where the system is installed. An octet string expressed as 'sddd.dd Ce…
1.3.6.1.4.1.2.3.51.2.2.2Nodevoltage
1.3.6.1.4.1.2.3.51.2.2.2.1NodeplanarVolt
1.3.6.1.4.1.2.3.51.2.2.2.1.1Scalarplus5Voltread-onlymandatory+5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for posit…
1.3.6.1.4.1.2.3.51.2.2.2.1.2Scalarplus3Pt3Voltread-onlymandatory+3.3 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for pos…
1.3.6.1.4.1.2.3.51.2.2.2.1.3Scalarplus12Voltread-onlymandatory+12 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for posi…
1.3.6.1.4.1.2.3.51.2.2.2.1.5Scalarminus5Voltread-onlymandatory-5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for posit…
1.3.6.1.4.1.2.3.51.2.2.2.1.6Scalarplus2Pt5Voltread-onlymandatory+2.5 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for pos…
1.3.6.1.4.1.2.3.51.2.2.2.1.8Scalarplus1Pt8Voltread-onlymandatory+1.8 Volt power supply voltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for pos…
1.3.6.1.4.1.2.3.51.2.2.3Nodeblowers
1.3.6.1.4.1.2.3.51.2.2.3.1Scalarblower1speedread-onlymandatoryBlower 1 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading …
1.3.6.1.4.1.2.3.51.2.2.3.2Scalarblower2speedread-onlymandatoryBlower 2 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading …
1.3.6.1.4.1.2.3.51.2.2.3.3Scalarblower3speedread-onlymandatoryBlower 3 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading …
1.3.6.1.4.1.2.3.51.2.2.3.4Scalarblower4speedread-onlymandatoryBlower 4 speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading …
1.3.6.1.4.1.2.3.51.2.2.3.10Scalarblower1Stateread-onlymandatoryThe health state for blower 1. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.11Scalarblower2Stateread-onlymandatoryThe health state for blower 2. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.12Scalarblower3Stateread-onlymandatoryThe health state for blower 3. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.13Scalarblower4Stateread-onlymandatoryThe health state for blower 4. NOTE: This MIB object is for BladeCenter T and BladeCenter S only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.20Scalarblower1speedRPMread-onlymandatoryBlower 1 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. Th…
1.3.6.1.4.1.2.3.51.2.2.3.21Scalarblower2speedRPMread-onlymandatoryBlower 2 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. Th…
1.3.6.1.4.1.2.3.51.2.2.3.22Scalarblower3speedRPMread-onlymandatoryBlower 3 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. Th…
1.3.6.1.4.1.2.3.51.2.2.3.23Scalarblower4speedRPMread-onlymandatoryBlower 4 speed expressed in RPM. If the blower is determined not to be running or the blower speed cannot be determined, the string will indicate 'Offline'. Th…
1.3.6.1.4.1.2.3.51.2.2.3.30Scalarblower1ControllerStateread-onlymandatoryThe health state for the controller for blower 1. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blo…
1.3.6.1.4.1.2.3.51.2.2.3.31Scalarblower2ControllerStateread-onlymandatoryThe health state for the controller for blower 2. NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only. NOTE: Blo…
1.3.6.1.4.1.2.3.51.2.2.3.32Scalarblower3ControllerStateread-onlymandatoryThe health state for the controller for blower 3. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also r…
1.3.6.1.4.1.2.3.51.2.2.3.33Scalarblower4ControllerStateread-onlymandatoryThe health state for the controller for blower 4. NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only. NOTE: Blowers are also r…
1.3.6.1.4.1.2.3.51.2.2.3.40Scalarblower1ExhaustTempread-onlymandatoryThe exhaust temperature in degrees Celsius for blower 1. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.41Scalarblower2ExhaustTempread-onlymandatoryThe exhaust temperature in degrees Celsius for blower 2. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.42Scalarblower3ExhaustTempread-onlymandatoryThe exhaust temperature in degrees Celsius for blower 3. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.3.43Scalarblower4ExhaustTempread-onlymandatoryThe exhaust temperature in degrees Celsius for blower 4. NOTE: This MIB object is for BCS only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.4NodepowerModuleHealth
1.3.6.1.4.1.2.3.51.2.2.4.1TablepowerModuleHealthTablenot-accessiblemandatoryTable of power module health information. Contains the power health information for each power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1RowpowerModuleHealthEntrynot-accessiblemandatoryPower Module health entry
1.3.6.1.4.1.2.3.51.2.2.4.1.1.1ColumnpowerModuleIndexread-onlymandatoryPower module sequence index.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.2ColumnpowerModuleExistsread-onlymandatoryIndicates whether the power module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.3ColumnpowerModuleStateread-onlymandatoryThe health state for the power module.
1.3.6.1.4.1.2.3.51.2.2.4.1.1.4ColumnpowerModuleDetailsread-onlymandatoryThe details for this power module.
1.3.6.1.4.1.2.3.51.2.2.5NodespStatus
1.3.6.1.4.1.2.3.51.2.2.5.2NodemmBistAndChassisStatus
1.3.6.1.4.1.2.3.51.2.2.5.2.1ScalarbistSdramread-onlydeprecatedMM BIST DRAM test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.2ScalarbistRs485Port1read-onlymandatoryMM BIST RS 485 legacy test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.3ScalarbistRs485Port2read-onlymandatoryMM BIST RS 485 local bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.4ScalarbistNvramread-onlydeprecatedMM BIST NVRAM test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.5ScalarbistRtcread-onlymandatoryMM BIST Real Time Clock test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.7ScalarbistLocalI2CBusread-onlymandatoryMM BIST Local I2C bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.8ScalarbistPrimaryMainAppFlashImageread-onlymandatoryMM BIST Primary Main Application Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.9ScalarbistSecondaryMainAppFlashImageread-onlymandatoryMM BIST Secondary Main Application test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.10ScalarbistBootRomFlashImageread-onlymandatoryMM BIST Boot Firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.11ScalarbistEthernetPort1read-onlymandatoryMM BIST external ethernet port test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.12ScalarbistEthernetPort2read-onlydeprecatedMM BIST internal ethernet port test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.13ScalarbistInternalPCIBusread-onlydeprecatedMM BIST PCI bus test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.14ScalarbistExternalI2CDevicesread-onlymandatoryMM BIST external I2C devices test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.15ScalarbistUSBControllerread-onlydeprecatedMM BIST USB controller test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.16ScalarbistVideoCompressorBoardread-onlydeprecatedMM BIST Video Compressor Board test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.17ScalarbistRemoteVideoread-onlydeprecatedMM BIST Remote Video test result. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.5.2.18ScalarbistPrimaryBusread-onlymandatoryMM BIST primary mid-plane bus test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.19ScalarbistInternalEthernetSwitchread-onlymandatoryMM BIST internal external switch test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.20ScalarbistVideoCaptureread-onlymandatoryMM BIST video capture test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.21ScalarbistUSBKeyboardMouseEmulationread-onlymandatoryMM BIST USB keyboard and mouse test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.22ScalarbistUSBMassStorageEmulationread-onlymandatoryMM BIST mass storage emulation test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.23ScalarbistUSBKeyboardMouseFirmwareread-onlymandatoryMM BIST USB keyboard and mouse firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.24ScalarbistUSBMassStorageFirmwareread-onlymandatoryMM BIST USB keyboard mouse firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.25ScalarbistPrimaryCoreread-onlymandatoryMM BIST primary core test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.26ScalarbistSecondaryCoreread-onlymandatoryMM BIST secondary core test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.27ScalarbistInternalIOExpanderread-onlymandatoryMM BIST internal IO expander test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.28ScalarbistRemoteControlFirmwareread-onlymandatoryMM BIST Remote Control firmware test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.29ScalarbistPhysicalNetworkLinkread-onlymandatoryMM BIST Physical Network Link test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.30ScalarbistLogicalNetworkLinkread-onlymandatoryMM BIST Logical Network Link test result.
1.3.6.1.4.1.2.3.51.2.2.5.2.33ScalarbistBladesInstalledread-onlymandatoryThe blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the…
1.3.6.1.4.1.2.3.51.2.2.5.2.49ScalarbistBladesCommunicatingread-onlymandatoryThe blades that are communicating on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as…
1.3.6.1.4.1.2.3.51.2.2.5.2.65ScalarbistBlowersInstalledread-onlymandatoryThe blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as t…
1.3.6.1.4.1.2.3.51.2.2.5.2.73ScalarbistBlowersFunctionalread-onlymandatoryThe blowers installed on the chassis that are functional. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is a…
1.3.6.1.4.1.2.3.51.2.2.5.2.74ScalarbistMediaTrayInstalledread-onlymandatoryIndicates whether a media tray is installed on the chassis.
1.3.6.1.4.1.2.3.51.2.2.5.2.75ScalarbistMediaTrayCommunicatingread-onlymandatoryIndicates whether a media tray is communicating.
1.3.6.1.4.1.2.3.51.2.2.5.2.76ScalarbistOtherMMInstalledread-onlymandatoryIndicates whether a redundant MM is installed.
1.3.6.1.4.1.2.3.51.2.2.5.2.77ScalarbistOtherMMCommunicatingread-onlymandatoryIndicates whether a redundant MM is communicating.
1.3.6.1.4.1.2.3.51.2.2.5.2.81ScalarbistPowerModulesInstalledread-onlymandatoryThe power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is …
1.3.6.1.4.1.2.3.51.2.2.5.2.89ScalarbistPowerModulesFunctionalread-onlymandatoryThe power modules that are functional on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is…
1.3.6.1.4.1.2.3.51.2.2.5.2.97ScalarbistSwitchModulesInstalledread-onlymandatoryThe switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that i…
1.3.6.1.4.1.2.3.51.2.2.5.2.113ScalarbistSwitchModulesCommunicatingread-onlymandatoryThe switch modules that are communicating on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's th…
1.3.6.1.4.1.2.3.51.2.2.5.2.200ScalarbistLastUpdateread-onlymandatoryIt is the time when the primary MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.3NodermmBistAndChassisStatus
1.3.6.1.4.1.2.3.51.2.2.5.3.2ScalarrbistRs485Port1read-onlymandatoryStandby MM BIST RS 485 legacy test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.3ScalarrbistRs485Port2read-onlymandatoryStandby MM BIST RS 485 local bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.5ScalarrbistRtcread-onlymandatoryStandby MM BIST Real Time Clock test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.7ScalarrbistLocalI2CBusread-onlymandatoryStandby MM BIST Local I2C bus test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.8ScalarrbistPrimaryMainAppFlashImageread-onlymandatoryStandby MM BIST Primary Main Application Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.9ScalarrbistSecondaryMainAppFlashImageread-onlymandatoryStandby MM BIST Secondary Main Application test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.10ScalarrbistBootRomFlashImageread-onlymandatoryStandby MM BIST Boot Firmware test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.11ScalarrbistEthernetPort1read-onlymandatoryStandby MM BIST external ethernet port test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.14ScalarrbistExternalI2CDevicesread-onlymandatoryStandby MM BIST external I2C devices test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.19ScalarrbistInternalEthernetSwitchread-onlymandatoryStandby MM BIST internal external switch test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.20ScalarrbistVideoCaptureread-onlymandatoryStandby MM BIST video capture test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdateTimePri…
1.3.6.1.4.1.2.3.51.2.2.5.3.21ScalarrbistUSBKeyboardMouseEmulationread-onlymandatoryStandby MM BIST USB keyboard and mouse test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpda…
1.3.6.1.4.1.2.3.51.2.2.5.3.22ScalarrbistUSBMassStorageEmulationread-onlymandatoryStandby MM BIST mass storage emulation test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpda…
1.3.6.1.4.1.2.3.51.2.2.5.3.23ScalarrbistUSBKeyboardMouseFirmwareread-onlymandatoryStandby MM BIST USB keyboard and mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying …
1.3.6.1.4.1.2.3.51.2.2.5.3.24ScalarrbistUSBMassStorageFirmwareread-onlymandatoryStandby MM BIST USB keyboard mouse firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbis…
1.3.6.1.4.1.2.3.51.2.2.5.3.25ScalarrbistPrimaryCoreread-onlymandatoryStandby MM BIST primary core test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.26ScalarrbistSecondaryCoreread-onlymandatoryStandby MM BIST secondary core test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.27ScalarrbistInternalIOExpanderread-onlymandatoryStandby MM BIST internal IO expander test result. The time of the last update can be obtained by querying rbistUpdateTime object.
1.3.6.1.4.1.2.3.51.2.2.5.3.28ScalarrbistRemoteControlFirmwareread-onlymandatoryStandby MM BIST Remote Control firmware test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpd…
1.3.6.1.4.1.2.3.51.2.2.5.3.29ScalarrbistPhysicalNetworkLinkread-onlymandatoryStandby MM BIST Physical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdat…
1.3.6.1.4.1.2.3.51.2.2.5.3.30ScalarrbistLogicalNetworkLinkread-onlymandatoryStandby MM BIST Logical Network Link test result collected when the standby MM was primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.33ScalarrbistBladesInstalledread-onlymandatoryThe blades that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePrim…
1.3.6.1.4.1.2.3.51.2.2.5.3.49ScalarrbistBladesCommunicatingread-onlymandatoryThe blades that were communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTime…
1.3.6.1.4.1.2.3.51.2.2.5.3.65ScalarrbistBlowersInstalledread-onlymandatoryThe blowers that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimePri…
1.3.6.1.4.1.2.3.51.2.2.5.3.73ScalarrbistBlowersFunctionalread-onlymandatoryThe blowers installed on the chassis that were functional when the standby MM was once primary. The time of the last update can be obtained by querying rbistUp…
1.3.6.1.4.1.2.3.51.2.2.5.3.74ScalarrbistMediaTrayInstalledread-onlymandatoryIndicates whether a media tray was installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbist…
1.3.6.1.4.1.2.3.51.2.2.5.3.75ScalarrbistMediaTrayCommunicatingread-onlymandatoryIndicates whether a media tray was communicating when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateTimeP…
1.3.6.1.4.1.2.3.51.2.2.5.3.76ScalarrbistOtherMMInstalledread-onlymandatoryIndicates whether a standby MM was installed when the standby MM was once primary.The time of the last update can be obtained by querying rbistUpdateTimePrimar…
1.3.6.1.4.1.2.3.51.2.2.5.3.77ScalarrbistOtherMMCommunicatingread-onlymandatoryIndicates whether a standby MM was communicating when the standby MM was once primary. The time of the last update can be gotten from the object 'rbistUpdateTi…
1.3.6.1.4.1.2.3.51.2.2.5.3.81ScalarrbistPowerModulesInstalledread-onlymandatoryThe power modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdateT…
1.3.6.1.4.1.2.3.51.2.2.5.3.89ScalarrbistPowerModulesFunctionalread-onlymandatoryThe power modules that were functional on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.97ScalarrbistSwitchModulesInstalledread-onlymandatoryThe switch modules that were installed on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpdate…
1.3.6.1.4.1.2.3.51.2.2.5.3.113ScalarrbistSwitchModulesCommunicatingread-onlymandatoryThe switch modules that are communicating on the chassis when the standby MM was once primary. The time of the last update can be obtained by querying rbistUpd…
1.3.6.1.4.1.2.3.51.2.2.5.3.200ScalarrbistUpdateTimeread-onlymandatoryIt is the time when the standby MM updated the last BIST results.
1.3.6.1.4.1.2.3.51.2.2.5.3.201ScalarrbistLastUpdatePrimaryread-onlymandatoryIt is the time when the standby MM updated the last BIST results when it was still primary.
1.3.6.1.4.1.2.3.51.2.2.6NodefanPack
1.3.6.1.4.1.2.3.51.2.2.6.1TablefanPackTablenot-accessiblemandatoryTable of fan pack information. Contains the information for each fan pack. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.6.1.1RowfanPackEntrynot-accessiblemandatoryFan Pack entry
1.3.6.1.4.1.2.3.51.2.2.6.1.1.1ColumnfanPackIndexread-onlymandatoryFan Pack sequence index.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.2ColumnfanPackExistsread-onlymandatoryIndicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.3ColumnfanPackStateread-onlymandatoryThe health state for the fan pack. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.4ColumnfanPackFanCountread-onlymandatoryThe number of fans in the fan pack.
1.3.6.1.4.1.2.3.51.2.2.6.1.1.5ColumnfanPackAverageSpeedread-onlymandatoryThe average speed of all fans in the fan pack expressed in percent(%) of maximum RPM. If the fan pack is determined not to be running or the fan pack speed can…
1.3.6.1.4.1.2.3.51.2.2.6.1.1.6ColumnfanPackAverageSpeedRPMread-onlymandatoryThe average speed of all fans in the fan pack expressed in RPM. If the fan pack is determined not to be running or the fan pack speed cannot be determined, the…
1.3.6.1.4.1.2.3.51.2.2.6.1.1.7ColumnfanPackControllerStateread-onlymandatoryThe health state for the controller for the fan pack. 0 = operational, 1 = flashing in progress, 2 = not present, 3 = communication error, 255 = unknown
1.3.6.1.4.1.2.3.51.2.2.7NodesystemHealth
1.3.6.1.4.1.2.3.51.2.2.7.1ScalarsystemHealthStatread-onlymandatoryIndicates status of system health for the system in which the MM resides. Value of 'critical' indicates a severe error has occurred and the system may not be f…
1.3.6.1.4.1.2.3.51.2.2.7.2TablesystemHealthSummaryTablenot-accessiblemandatoryTable of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCe…
1.3.6.1.4.1.2.3.51.2.2.7.2.1RowsystemHealthSummaryEntrynot-accessiblemandatorySystem Health Summary entry NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.1ColumnsystemHealthSummaryIndexread-onlymandatorySystem health summary index. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.2ColumnsystemHealthSummarySeverityread-onlymandatorySystem health summary severity. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.3ColumnsystemHealthSummaryDescriptionread-onlymandatorySystem health summary description. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.7.2.1.4ColumnsystemHealthSummaryDateTimeread-onlymandatorySystem health summary date time. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8Nodeleds
1.3.6.1.4.1.2.3.51.2.2.8.1NodefrontPanelLEDs
1.3.6.1.4.1.2.3.51.2.2.8.1.1ScalarsystemErrorLEDread-onlymandatoryIndicates whether the front panel system error LED is on or off. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8.1.2ScalarinformationLEDread-writemandatoryIndicates whether the front panel system information LED is on or off. For Write access, the LED can be turned off only. NOTE: This MIB object is for BladeCent…
1.3.6.1.4.1.2.3.51.2.2.8.1.3ScalartemperatureLEDread-onlymandatoryIndicates whether the front panel temperature LED is on or off. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8.1.4ScalaridentityLEDread-writemandatoryIndicates whether the front panel identity LED is on or off. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.8.2NodebladeLEDs
1.3.6.1.4.1.2.3.51.2.2.8.2.1TablebladeLEDsTablenot-accessiblemandatoryTable of blade status information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query timeout …
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1RowbladeLEDsEntrynot-accessiblemandatoryBlade system status entry
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.1ColumnledBladeIndexread-onlymandatoryBlade LED table index.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.2ColumnledBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.3ColumnledBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.4ColumnledBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.5ColumnledBladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.6ColumnledBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.7ColumnledBladeSystemErrorread-onlymandatoryIndicates whether the blade system error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.8ColumnledBladeInformationread-writemandatoryIndicates whether the blade information LED is on or off. For Write access, the LED can be turned off only.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.9ColumnledBladeKVMread-onlymandatoryIndicates whether the blade KVM LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.10ColumnledBladeMediaTrayread-onlymandatoryIndicates whether the blade media tray LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.1.1.11ColumnledBladeIdentityread-writemandatoryIndicates whether the blade identify LED is on, off, or blinking.
1.3.6.1.4.1.2.3.51.2.2.8.2.2TablebladeLEDsDetailsTablenot-accessiblemandatoryTable of blade LEDs detailed information. NOTE: Querying objects in this table may take significantly longer than normal, so it is recommended that the query t…
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1RowbladeLEDsDetailsEntrynot-accessiblemandatoryBlade LEDs Details entry
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.1ColumnledIndexread-onlymandatoryThe LED index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.2ColumnledBladeBayNumberread-onlymandatoryThe bay number of the main server blade that the LED is grouped into. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.3ColumnledBladeComponentTyperead-onlymandatoryType of the component/subcomponent grouping for this LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.4ColumnledBladeLabelread-onlymandatoryText label for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.5ColumnledBladeStateread-onlymandatoryText description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.2.2.1.6ColumnledBladeLocationread-onlymandatoryLocation of this LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.8.3NodetelcoPanelLEDs
1.3.6.1.4.1.2.3.51.2.2.8.3.1ScalarcriticalLEDread-onlymandatoryIndicates whether the BladeCenter T Panel CRT (Critical) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.2ScalarmajorLEDread-onlymandatoryIndicates whether the BladeCenter T Panel MJR (Major) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.3ScalarminorLEDread-onlymandatoryIndicates whether the BladeCenter T Panel MNR (Minor) LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.4ScalartelcoIdentityLEDread-writemandatoryIndicates whether the BladeCenter T Panel identity LED is on or off. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.5ScalartelcoColorSelread-writemandatoryIndicates whether the BladeCenter T Critical and Major LEDs are displayed in amber or red color. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.3.6ScalarcriticalityAssertionModeread-writemandatoryIndicates whether the BladeCenter T Criticality Assertion Mode is enabled or disabled. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.8.4NodesmLEDs
1.3.6.1.4.1.2.3.51.2.2.8.4.1TablesmLEDsTablenot-accessiblemandatoryTable of switch module LEDs information.
1.3.6.1.4.1.2.3.51.2.2.8.4.1.1RowsmLEDsEntrynot-accessiblemandatorySwitch module LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.1ColumnledSMIndexread-onlymandatorySwitch module LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.4.1.1.2ColumnledSMLEDsread-onlymandatoryA bitmap of LEDs information on the selected switch module. The bitmap is a string containing a list of 1's and 0's. Every 4 bytes are used to represent a led …
1.3.6.1.4.1.2.3.51.2.2.8.5NodeblowerLEDs
1.3.6.1.4.1.2.3.51.2.2.8.5.1TableblowerLEDsTablenot-accessiblemandatoryTable of blower LEDs information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1RowblowerLEDsEntrynot-accessiblemandatoryBlower LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.1ColumnledBlowerIndexread-onlymandatoryBlower LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.2ColumnledBlowerIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.3ColumnledBlowerExistsread-onlymandatoryIndicates whether the blower specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.5.1.1.4ColumnledBlowerErrorread-onlymandatoryIndicates whether the blower error LED is on, off, or not available.
1.3.6.1.4.1.2.3.51.2.2.8.6NodefanPackLEDs
1.3.6.1.4.1.2.3.51.2.2.8.6.1TablefanPackLEDsTablenot-accessiblemandatoryTable of fan pack LEDs information. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1RowfanPackLEDsEntrynot-accessiblemandatoryFan Pack LEDs information entry
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.1ColumnledFanPackIndexread-onlymandatoryFan Pack LEDs table index.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.2ColumnledFanPackIdread-onlymandatoryThe numeric fan pack ID.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.3ColumnledFanPackExistsread-onlymandatoryIndicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.8.6.1.1.4ColumnledFanPackErrorread-onlymandatoryIndicates whether the fan pack error LED is on or off.
1.3.6.1.4.1.2.3.51.2.2.8.7NodemtStatusLEDs
1.3.6.1.4.1.2.3.51.2.2.8.7.1TablemtStatusLEDsTablenot-accessiblemandatoryTable of Media Tray Status LEDs information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1RowmtStatusLEDsEntrynot-accessiblemandatoryMedia Tray Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.1ColumnledMediaTrayIndexread-onlymandatoryMedia Tray Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.2ColumnledMediaTrayIdread-onlymandatoryThe numeric Media Tray ID. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.3ColumnledMediaTrayExistsread-onlymandatoryIndicates whether the Media Tray exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.7.1.1.5ColumnledMediaTrayFaultread-onlymandatoryIndicates whether the Media Tray Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.8NodetapStatusLEDs
1.3.6.1.4.1.2.3.51.2.2.8.8.3ScalartapExistsread-onlymandatoryIndicates whether the Alarm Panel exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.8.4ScalartapFRRLEDread-onlymandatoryIndicates whether the Alarm Panel Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.8.5ScalartapFaultLEDread-onlymandatoryIndicates whether the Alarm Panel Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9NodencStatusLEDs
1.3.6.1.4.1.2.3.51.2.2.8.9.1TablencStatusLEDsTablenot-accessibledeprecatedTable of Network Clock Status LEDs information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1RowncStatusLEDsEntrynot-accessibledeprecatedNetwork Clock Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.1ColumnledNetworkClockIndexread-onlydeprecatedNetwork Clock Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.2ColumnledNetworkClockIdread-onlydeprecatedThe numeric Network Clock ID. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.3ColumnledNetworkClockExistsread-onlydeprecatedIndicates whether the Network Clock exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.4ColumnledNetworkClockFRRread-onlydeprecatedIndicates whether the Network Clock Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.9.1.1.5ColumnledNetworkClockFaultread-onlydeprecatedIndicates whether the Network Clock Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10NodemxStatusLEDs
1.3.6.1.4.1.2.3.51.2.2.8.10.1TablemxStatusLEDsTablenot-accessiblemandatoryTable of Multiplexer Expansion Module Status LEDs information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1RowmxStatusLEDsEntrynot-accessiblemandatoryMultiplexer Expansion Module Status LEDs information entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.1ColumnledMuxIndexread-onlymandatoryMultiplexer Expansion Module Status LEDs table index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.2ColumnledMuxIdread-onlymandatoryThe numeric Multiplexer Expansion Module ID. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.3ColumnledMuxExistsread-onlymandatoryIndicates whether the Multiplexer Expansion Module exists or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.4ColumnledMuxFRRread-onlymandatoryIndicates whether the Multiplexer Expansion Module Safe To Remove LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.10.1.1.5ColumnledMuxFaultread-onlymandatoryIndicates whether the Multiplexer Expansion Module Fault LED is on or off. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.8.11NodestorageLEDs
1.3.6.1.4.1.2.3.51.2.2.8.11.1TablestorageLEDsTablenot-accessiblemandatoryTable of storage module LEDs information. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1RowstorageLEDsEntrynot-accessiblemandatoryStorage Module LEDs information entry NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.1ColumnledStorageIndexread-onlymandatoryStorage Module LEDs table index. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.2ColumnledStorageIdread-onlymandatoryThe numeric storage module ID. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.3ColumnledStorageExistsread-onlymandatoryIndicates whether the storage module specified exists or not. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.8.11.1.1.4ColumnledStorageErrorread-onlymandatoryIndicates the status of the storage module error LED. NOTE: This MIB object is for BladeCenter S only.
1.3.6.1.4.1.2.3.51.2.2.9NodetelcoSystemHealth
1.3.6.1.4.1.2.3.51.2.2.9.1ScalartelcoSystemHealthStatread-onlymandatoryIndicates status of system health for the system in which the MM resides. Value of 'critical' indicates a non-recoverable service affecting condition has occur…
1.3.6.1.4.1.2.3.51.2.2.9.2TabletelcoSystemHealthSummaryTablenot-accessiblemandatoryTable of System Health summary. Contains more detailed information about the reasons for the overall system health status. NOTE: This MIB object is for BladeCe…
1.3.6.1.4.1.2.3.51.2.2.9.2.1RowtelcoSystemHealthSummaryEntrynot-accessiblemandatoryBladeCenter T System Health Summary entry. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.1ColumntelcoSystemHealthSummaryIndexread-onlymandatoryBladeCenter T System Health Summary Index. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.2ColumntelcoSystemHealthSummarySeverityread-onlymandatoryBladeCenter T System Health Summary Severity. The values and meanings are as follows: 0x06 Critical-Power 0x05 Critical 0x04 Major-Power 0x03 Major 0x02 Minor-…
1.3.6.1.4.1.2.3.51.2.2.9.2.1.3ColumntelcoSystemHealthSummaryDescriptionread-onlymandatoryBladeCenter T System Health Summary Description. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No …
1.3.6.1.4.1.2.3.51.2.2.9.2.1.4ColumntelcoSystemHealthSummaryEventNameread-onlymandatoryBladeCenter T System Health Summary Event Name. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.9.2.1.5ColumntelcoSystemHealthSummaryEventKeyIDread-onlymandatoryBladeCenter T System Health Summary Event Key ID. An octet string expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255) or bla…
1.3.6.1.4.1.2.3.51.2.2.9.2.1.6ColumntelcoSystemHealthSummaryAcknowledgeread-onlymandatoryBladeCenter T System Health Summary Acknowledge. Indicates whether the alarm event is acknowledged or unacknowledged. NOTE: This MIB object is for BladeCenter …
1.3.6.1.4.1.2.3.51.2.2.9.2.1.7ColumntelcoSystemHealthSummaryAssertTimeread-onlymandatoryBladeCenter T System Health Summary Assert Time. NOTE: This MIB object is for BladeCenter T only. NOTE: If no alarms are in progress, this object contains 'No …
1.3.6.1.4.1.2.3.51.2.2.10NodefuelGauge
1.3.6.1.4.1.2.3.51.2.2.10.1NodefuelGaugeInformation
1.3.6.1.4.1.2.3.51.2.2.10.1.1TablefuelGaugeTablenot-accessiblemandatoryTable of Fuel Gauge information.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1RowfuelGaugeEntrynot-accessiblemandatoryFuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.1ColumnfuelGaugeIndexread-onlymandatoryFuel Gauge Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.2ColumnfuelGaugePowerDomainNumberread-onlymandatoryFuel Gauge Table Power Domain Number.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.3ColumnfuelGaugeStatusread-onlymandatoryFuel Gauge Table Status for the power domain. The response will start out with a numeric value (0 = unknown, 1 = good, 2 = warning, and 3: bad), followed by a …
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.4ColumnfuelGaugeFirstPowerModuleread-onlymandatoryFuel Gauge Table First Power Module capacity in Watts in the power domain. NOTE: First power module in power domain 1 and 2 is in bay 1 and 3 respectively.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.5ColumnfuelGaugeSecondPowerModuleread-onlymandatoryFuel Gauge Table Second Power Module capacity in Watts in the power domain. NOTE: Second power module in power domain 1 and 2 is in bay 2 and 4 respectively.
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.6ColumnfuelGaugePowerManagementPolicySettingread-onlymandatoryFuel Gauge Table for the Power Management Policy Setting for each power domain. When a 1200W or 1400W power module is installed in the domain the power managem…
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.7ColumnfuelGaugeTotalPowerread-onlymandatoryThis field displays the total available power for each power domain based on installed power modules and the current Power Management Policy Setting. When a 12…
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.8ColumnfuelGaugeAllocatedPowerread-onlymandatoryThis field displays the power that has been reserved in each power domain. NOTE: 1) Power is always reserved in domain 1 for two management modules and two I/O…
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.9ColumnfuelGaugeRemainingPowerread-onlymandatoryThis field displays the remaining power available in each domain. Remaining Power = Total Power minus Power In Use When a 1200W or 1400W power module is instal…
1.3.6.1.4.1.2.3.51.2.2.10.1.1.1.10ColumnfuelGaugePowerInUsedread-onlymandatoryThis field displays the total power being used in each power domain. When a 1200W or 1400W power module is installed in the domain the power management policy …
1.3.6.1.4.1.2.3.51.2.2.10.2NodepowerDomain1
1.3.6.1.4.1.2.3.51.2.2.10.2.1TablepowerDomain1Tablenot-accessiblemandatoryTable of Power Domain 1. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1RowpowerDomain1Entrynot-accessiblemandatoryFuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.1Columnpd1Indexread-onlymandatoryPower Domain 1 Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.2Columnpd1BayNumberread-onlymandatoryPower Domain 1 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: notApplicable(1), notApplicable(2), blowerBay1(3), blowerBay2(4), ma…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.3Columnpd1BladePrimarySlotread-onlymandatoryPower Domain 1 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is d…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.4Columnpd1ModuleStatusread-onlymandatoryPower Domain 1 Table Module Throttle Status.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.5Columnpd1ModuleNameread-onlymandatoryPower Domain 1 Table Module Name.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.6Columnpd1ModuleStateread-onlymandatoryPower Domain 1 Table Module State.
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.7Columnpd1ModuleAllocatedPowerCurrentread-onlymandatoryPower Domain 1 Table Allocated Power Current indicates the current power allocation for the module in Watts. When a 1200W or 1400W power module is installed in…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.8Columnpd1ModuleAllocatedPowerMaxread-onlymandatoryPower Domain 1 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the mo…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.9Columnpd1ModuleAllocatedPowerMinread-onlymandatoryPower Domain 1 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of t…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.10Columnpd1ModuleCPUDutyCyclesread-onlymandatoryPower Domain 1 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that som…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.11Columnpd1ModuleThrottleread-onlymandatoryPower Domain 1 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in t…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.12Columnpd1ModulePowerCapabilitiesread-onlymandatoryPower Domain 1 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module wit…
1.3.6.1.4.1.2.3.51.2.2.10.2.1.1.13Columnpd1ModuleMeasuredOrStaticread-onlymandatoryPower Domain 1 Table Module Measured Or Static.
1.3.6.1.4.1.2.3.51.2.2.10.2.3NodepowerDomain1PowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.2.3.1Scalarpd1PowerTrendingPeriodread-writemandatorySpecify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power…
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10Tablepd1PowerTrendingSampleTablenot-accessiblemandatoryTable of Power Domain 1 Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1Rowpd1PowerTrendingSampleEntrynot-accessiblemandatoryPower Domain 1 Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.1Columnpd1PowerTrendingSampleIndexread-onlymandatoryPower Domain 1 Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.2Columnpd1PowerTrendingSampleTimeStampread-onlymandatoryPower Domain 1 Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.2.3.10.1.3Columnpd1PowerTrendingSampleAveread-onlymandatoryPower Domain 1 Power Trending Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.3NodepowerDomain2
1.3.6.1.4.1.2.3.51.2.2.10.3.1TablepowerDomain2Tablenot-accessiblemandatoryTable of Power Domain 2. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1RowpowerDomain2Entrynot-accessiblemandatoryFuel Gauge entry
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.1Columnpd2Indexread-onlymandatoryPower Domain 2 Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.2Columnpd2BayNumberread-onlymandatoryPower Domain 2 Table Bay Number. The following Bay Number IDs are used in the BladeCenter: serverBladeBay7(1), serverBladeBay8(2), serverBladeBay9(3), serverBl…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.3Columnpd2BladePrimarySlotread-onlymandatoryPower Domain 2 Table Blade Primary Slot can be useful when a server blade spans multiple slots (e.g. double wide or triple wide). For example if the blade is d…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.4Columnpd2ModuleStatusread-onlymandatoryPower Domain 2 Table Module throttle status.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.5Columnpd2ModuleNameread-onlymandatoryPower Domain 2 Table Module Name.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.6Columnpd2ModuleStateread-onlymandatoryPower Domain 2 Table Power State.
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.7Columnpd2ModuleAllocatedPowerCurrentread-onlymandatoryPower Domain 2 Table Allocated Power Current indicates the current power allocation for the module. When a 1200W or 1400W power module is installed in the doma…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.8Columnpd2ModuleAllocatedPowerMaxread-onlymandatoryPower Domain 2 Table Allocated Power Max indicates the maximum power allocation for the module in Watts. It is indicative of the maximum amount of power the mo…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.9Columnpd2ModuleAllocatedPowerMinread-onlymandatoryPower Domain 2 Table Allocated Power Min indicates the minumum power allocation for the module in Watts. It is indicative of the minumum power consumption of t…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.10Columnpd2ModuleCPUDutyCyclesread-onlymandatoryPower Domain 2 Table Module CPUs Duty Cycles applies to blade servers only. It displays the duty cycle for each CPU on the blade as a percentage. Note that som…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.11Columnpd2ModuleThrottleread-onlymandatoryPower Domain 2 Table Module Throttle indicates whether the server blade may be allowed to throttle or not. When a 1200W or 1400W power module is installed in t…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.12Columnpd2ModulePowerCapabilitiesread-onlymandatoryPower Domain 2 Table Module Power Capabilities. staticPowerManagement: the module with the static worst case power values. fixedPowermanagement: the module wit…
1.3.6.1.4.1.2.3.51.2.2.10.3.1.1.13Columnpd2ModuleMeasuredOrStaticread-onlymandatoryPower Domain 2 Table Module Measured Or Static.
1.3.6.1.4.1.2.3.51.2.2.10.3.3NodepowerDomain2PowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.3.3.1Scalarpd2PowerTrendingPeriodread-writemandatorySpecify time period for power domain 2 power trending information table view. NOTE: This time period should be configured before displaying the following Power…
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10Tablepd2PowerTrendingSampleTablenot-accessiblemandatoryTable of Power Domain 2 Power Trending Sample Information.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1Rowpd2PowerTrendingSampleEntrynot-accessiblemandatoryPower Domain 2 Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.1Columnpd2PowerTrendingSampleIndexread-onlymandatoryPower Domain 2 Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.2Columnpd2PowerTrendingSampleTimeStampread-onlymandatoryPower Domain 2 Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.3.3.10.1.3Columnpd2PowerTrendingSampleAveread-onlymandatoryPower Domain 2 Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4NodemoduleInformation
1.3.6.1.4.1.2.3.51.2.2.10.4.1NodebladeDetails
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1TablebladeDetailsTablenot-accessiblemandatoryTable of Blade Module Details.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1RowbladeDetailsEntrynot-accessiblemandatoryBlade Module Details entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.1ColumnbladeDetailsIndexread-onlymandatoryBlade Module Details Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.2ColumnbladeDetailsIdread-onlymandatoryBlade Module Details Table Blade Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.3ColumnbladeDetailsMaxPowerConfigread-writemandatoryBlade Module Details Table Maximum Power Configuration. Allow the user to set the maximum power that can be used by the blade. This function is also known as p…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.4ColumnbladeDetailsEffectiveClockRateread-onlymandatoryBlade Module Details Table Effective CPU Clock Rate applies to DPM blades only. It displays processor's effective clock rate based on sample interval. Note tha…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.5ColumnbladeDetailsMaximumClockRateread-onlymandatoryBlade Module Details Table Maximum CPU Clock Rate applies to DPM blades only. It displays processor's maximum clock rate based on sample interval. Note that so…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.6ColumnbladeDetailsPowerSaverModeread-writemandatoryWhen enabled, the static low power saver mode allows the blade to selectively alter its operating voltage and frequency to reduce power consumption. This featu…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.7ColumnbladeDetailsDynamicPowerSaverread-writemandatoryWhen enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade to be controlled based on how busy the CPU is. This feature is not …
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.8ColumnbladeDetailsDynamicPowerFavorPerformanceOverPowerread-writemandatoryWhen enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the system past its nominal CPU frequency when CPU and mem…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.1.1.9ColumnbladeDetailsPowerControlread-writemandatoryThis object is used to get or set the power control setting on a blade. If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned.…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3NodebladePowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.1ScalarbladePowerTrendingPeriodread-writemandatorySpecify time period for blade module power trending information table view. NOTE: This time period should be configured before displaying the following Power T…
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.2ScalarbladePowerTrendingBladeIdread-writemandatoryBlade Module Power Trending Blade Id. NOTE: The Blade Id should be configured before displaying the bladePowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10TablebladePowerTrendingSampleTablenot-accessiblemandatoryTable of Blade Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1RowbladePowerTrendingSampleEntrynot-accessiblemandatoryBlade Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.1ColumnbladePowerTrendingSampleIndexread-onlymandatoryBlade Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.2ColumnbladePowerTrendingSampleIdread-onlymandatoryBlade Module Power Trending Sample Table Blade Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.3ColumnbladePowerTrendingSampleTimeStampread-onlymandatoryBlade Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.4ColumnbladePowerTrendingSampleMaxread-onlymandatoryBlade Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.5ColumnbladePowerTrendingSampleMinread-onlymandatoryBlade Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.1.3.10.1.6ColumnbladePowerTrendingSampleAveread-onlymandatoryBlade Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2NodeswitchDetails
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3NodeswitchPowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.1ScalarswitchPowerTrendingPeriodread-writemandatorySpecify time period for switch module power trending information table view. NOTE: This time period should be configured before displaying the following Power …
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.2ScalarswitchPowerTrendingSwitchIdread-writemandatorySwitch Module Power Trending Switch Id. NOTE: The Switch Id should be configured before displaying the switchPowerTrendingTable.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10TableswitchPowerTrendingSampleTablenot-accessiblemandatoryTable of Switch Module Power Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1RowswitchPowerTrendingSampleEntrynot-accessiblemandatorySwitch Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.1ColumnswitchPowerTrendingSampleIndexread-onlymandatorySwitch Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.2ColumnswitchPowerTrendingSampleIdread-onlymandatorySwitch Module Power Trending Sample Table Switch Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.3ColumnswitchPowerTrendingSampleTimeStampread-onlymandatorySwitch Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.4ColumnswitchPowerTrendingSampleMaxread-onlymandatorySwitch Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.5ColumnswitchPowerTrendingSampleMinread-onlymandatorySwitch Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.2.3.10.1.6ColumnswitchPowerTrendingSampleAveread-onlymandatorySwitch Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3NodeblowerDetails
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3NodeblowerPowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.1ScalarblowerPowerTrendingPeriodread-writemandatorySpecify time period for blower module power trending information table view. NOTE: This time period should be configured before displaying the following Power …
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.2ScalarblowerPowerTrendingBlowerIdread-writemandatoryBlower Module Power Trending Blower Id. NOTE: The Blower Id should be configured before displaying the blowerPowerTrendingTable. NOTE: Blowers are also referre…
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10TableblowerPowerTrendingSampleTablenot-accessiblemandatoryTable of Blower Module Power Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1RowblowerPowerTrendingSampleEntrynot-accessiblemandatoryBlower Module Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.1ColumnblowerPowerTrendingSampleIndexread-onlymandatoryBlower Module Power Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.2ColumnblowerPowerTrendingSampleIdread-onlymandatoryBlower Module Power Trending Sample Table Blower Id.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.3ColumnblowerPowerTrendingSampleTimeStampread-onlymandatoryBlower Module Power Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.4ColumnblowerPowerTrendingSampleMaxread-onlymandatoryBlower Module Power Trending Sample Table Maximum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.5ColumnblowerPowerTrendingSampleMinread-onlymandatoryBlower Module Power Trending Sample Table Minimum Power.
1.3.6.1.4.1.2.3.51.2.2.10.4.3.3.10.1.6ColumnblowerPowerTrendingSampleAveread-onlymandatoryBlower Module Power Trending Sample Table Average Power.
1.3.6.1.4.1.2.3.51.2.2.10.5NodechassisInformation
1.3.6.1.4.1.2.3.51.2.2.10.5.1NodechassisConfiguration
1.3.6.1.4.1.2.3.51.2.2.10.5.1.1ScalarchassisTotalDCPowerAvailableread-onlymandatoryChassis total DC power available, which displays the total DC power available for the entire chassis. It is the sum of the two power domains.
1.3.6.1.4.1.2.3.51.2.2.10.5.1.2ScalarchassisTotalACPowerInUsedread-onlymandatoryChassis total AC power being used, which displays the total AC power being consumed by all modules in the chassis. It also includes power consumed by the blowe…
1.3.6.1.4.1.2.3.51.2.2.10.5.1.3ScalarchassisTotalThermalOutputread-onlymandatoryChassis total thermal output, which displays the thermal output (load) in BTUs per hour. It is calculated based on the total AC power in use. (1 Watt = 3.412 B…
1.3.6.1.4.1.2.3.51.2.2.10.5.1.4ScalarchassisTrendingSampleIntervalread-writemandatoryChassis Power and Thermal Trending Sample Interval. 0 means no trending. the minimum interval is 10 minutes and the maximum is 60 minutes, in 5 minute incremen…
1.3.6.1.4.1.2.3.51.2.2.10.5.1.5ScalarchassisPowerServiceread-onlymandatoryThe chassis power service mode. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.10.5.3NodechassisPowerTrending
1.3.6.1.4.1.2.3.51.2.2.10.5.3.1ScalarchassisPowerTrendingPeriodread-writemandatorySpecify time period of power trending information. NOTE: This time period should be configured before displaying the following Power Trending Information table…
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10TablechassisPowerTrendingSampleTablenot-accessiblemandatoryTable of Chassis Power Trending Sample Information in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1RowchassisPowerTrendingSampleEntrynot-accessiblemandatoryChassis Power Trending Sample entry in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.1ColumnchassisPowerTrendingSampleIndexread-onlymandatoryChassis Power Trending Sample Index in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.2ColumnchassisPowerTrendingSampleTimeStampread-onlymandatoryChassis Power Trending Sample Timestamp in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.3.10.1.3ColumnchassisPowerTrendingSampleAveread-onlymandatoryChassis Power Trending Sample Average Power in specified time period.
1.3.6.1.4.1.2.3.51.2.2.10.5.5NodechassisThermalTrending
1.3.6.1.4.1.2.3.51.2.2.10.5.5.1ScalarchassisThermalTrendingPeriodread-writemandatorySpecify time period of thermal trending information. NOTE: This time period should be configured before displaying the following Thermal Trending Information t…
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10Tablemt1ThermalTrendingTablenot-accessiblemandatoryTable of Media Tray 1 Thermal Trending Information.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1Rowmt1ThermalTrendingEntrynot-accessiblemandatoryMedia Tray 1 Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.1Columnmt1ThermalTrendingIndexread-onlymandatoryMedia Tray 1 Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.2Columnmt1ThermalTrendingTimeStampread-onlymandatoryMedia Tray 1 Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.10.1.3Columnmt1ThermalTrendingTemperatureread-onlymandatoryMedia Tray 1 Thermal Trending Table Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15Tablemt2ThermalTrendingTablenot-accessiblemandatoryTable of Media Tray 2 Thermal Trending Information. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1Rowmt2ThermalTrendingEntrynot-accessiblemandatoryMedia Tray 2 Thermal Trending entry. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.1Columnmt2ThermalTrendingIndexread-onlymandatoryMedia Tray 2 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.2Columnmt2ThermalTrendingTimeStampread-onlymandatoryMedia Tray 2 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.15.1.3Columnmt2ThermalTrendingTemperatureread-onlymandatoryMedia Tray 2 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20Tableblower1ThermalTrendingTablenot-accessiblemandatoryTable of Blower 1 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1Rowblower1ThermalTrendingEntrynot-accessiblemandatoryBlower 1 Thermal Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.1Columnblower1ThermalTrendingIndexread-onlymandatoryBlower 1 Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.2Columnblower1ThermalTrendingTimeStampread-onlymandatoryBlower 1 Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.20.1.3Columnblower1ThermalTrendingTemperatureread-onlymandatoryBlower 1 Thermal Trending Table Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30Tableblower2ThermalTrendingTablenot-accessiblemandatoryTable of Blower 2 Thermal Trending Information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1Rowblower2ThermalTrendingEntrynot-accessiblemandatoryBlower Thermal 2 Trending entry.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.1Columnblower2ThermalTrendingIndexread-onlymandatoryBlower 2 Thermal Trending Table Index.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.2Columnblower2ThermalTrendingTimeStampread-onlymandatoryBlower 2 Thermal Trending Table Sample Timestamp.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.30.1.3Columnblower2ThermalTrendingTemperatureread-onlymandatoryBlower 2 Thermal Trending Table Temperature.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40Tableblower3ThermalTrendingTablenot-accessiblemandatoryTable of Blower 3 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1Rowblower3ThermalTrendingEntrynot-accessiblemandatoryBlower 3 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.1Columnblower3ThermalTrendingIndexread-onlymandatoryBlower 3 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.2Columnblower3ThermalTrendingTimeStampread-onlymandatoryBlower 3 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.40.1.3Columnblower3ThermalTrendingTemperatureread-onlymandatoryBlower 3 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50Tableblower4ThermalTrendingTablenot-accessiblemandatoryTable of Blower 4 Thermal Trending Information. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1Rowblower4ThermalTrendingEntrynot-accessiblemandatoryBlower 4 Thermal Trending entry. NOTE: This MIB object is for BladeCenter T only. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.1Columnblower4ThermalTrendingIndexread-onlymandatoryBlower 4 Thermal Trending Table Index. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.2Columnblower4ThermalTrendingTimeStampread-onlymandatoryBlower 4 Thermal Trending Table Sample Timestamp. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.5.5.50.1.3Columnblower4ThermalTrendingTemperatureread-onlymandatoryBlower 4 Thermal Trending Table Temperature. NOTE: This MIB object is for BladeCenter T only.
1.3.6.1.4.1.2.3.51.2.2.10.6NodepowerPolicyInformation
1.3.6.1.4.1.2.3.51.2.2.10.6.1TablepowerPolicyTablenot-accessiblemandatoryTable of Power Policy information for all power domains. Reading this table can tell you about the available power policies that can be configured for a domain…
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1RowpowerPolicyEntrynot-accessiblemandatoryPower Policy Entry
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.1ColumnpowerPolicyIndexread-onlymandatoryThe unique idenitifier of a row in the powerPolicyTable.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.2ColumnpowerPolicyPowerDomainNumberread-onlymandatoryThe power domain number which this row is associated with.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.3ColumnpowerPolicyNameread-onlymandatoryThe short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single AC power…
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.4ColumnpowerPolicyPwrSupplyFailureLimitread-onlymandatoryThe maximum number of power supplies that can fail in a chassis while still providing redundancy.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.5ColumnpowerPolicyMaxPowerLimitread-onlymandatoryThe maximum power available (in watts), based on the number of power modules and the Power Management Policy setting.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.6ColumnpowerPolicyEstimatedUtilizationread-onlymandatoryThe estimated utilization (as a percentage) based on current power usage.
1.3.6.1.4.1.2.3.51.2.2.10.6.1.1.7ColumnpowerPolicyActivateread-writemandatoryWhen read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain…
1.3.6.1.4.1.2.3.51.2.2.12Nodefrontbezel
1.3.6.1.4.1.2.3.51.2.2.12.1ScalarfrontbezelExistsread-onlymandatoryIndicates whether the front bezel is installed or not. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.17Nodeusers
1.3.6.1.4.1.2.3.51.2.2.17.1NodemmUsers
1.3.6.1.4.1.2.3.51.2.2.17.1.1TablecurrentlyLoggedInTablenot-accessiblemandatoryTable of MM users currently logged in. NOTE: This MIB object is for AMM only.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1RowcurrentlyLoggedInEntrynot-accessiblemandatoryMM users currently logged in entries. NOTE: This MIB object is for AMM only.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.1ColumncurrentlyLoggedInEntryIndexread-onlymandatoryIndex for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.2ColumncurrentlyLoggedInEntryUserIdread-onlymandatoryName for MM users currently logged in. NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent.
1.3.6.1.4.1.2.3.51.2.2.17.1.1.1.3ColumncurrentlyLoggedInEntryAccMethodread-onlymandatoryAccess method for MM users currently logged in.
1.3.6.1.4.1.2.3.51.2.2.20NodemonitorThresholds
1.3.6.1.4.1.2.3.51.2.2.20.2NodevoltageThresholds
1.3.6.1.4.1.2.3.51.2.2.20.2.1TablevoltageThresholdsTablenot-accessiblemandatoryTable of voltage threshold entries. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1RowvoltageThresholdsEntrynot-accessiblemandatoryVoltage threshold entries. NOTE: This MIB object is for BladeCenter only.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.1ColumnvoltageThresholdEntryIndexread-onlymandatoryIndex for voltage threshold entry.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.2ColumnvoltageThresholdEntryNameread-onlymandatoryVoltage threshold entry null terminated string that contains the power supply's name, for example '+5V'.
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.3ColumnvoltageThresholdEntryCurrentValueread-onlymandatoryVoltage reading expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive) d is a decimal d…
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.6ColumnvoltageThresholdEntryWarningHighValueread-onlymandatoryVoltage threshold reading expressed in Volts(V). If the voltage rises above this value, a warning alert/event, if enabled, will be generated. An octet string e…
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.7ColumnvoltageThresholdEntryWarningResetHighValueread-onlymandatoryVoltage threshold reading expressed in Volts(V). If the voltage rises above this value and if a warning alert/event had previously been created, then the alert…
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.10ColumnvoltageThresholdEntryWarningLowValueread-onlymandatoryVoltage threshold reading expressed in Volts(V). If the voltage drops below this value, a warning alert/event, if enabled, will be generated. An octet string e…
1.3.6.1.4.1.2.3.51.2.2.20.2.1.1.11ColumnvoltageThresholdEntryWarningResetLowValueread-onlymandatoryVoltage threshold reading expressed in Volts(V). If the voltage drops below this value and if a warning alert/event had previously been created, then the alert…
1.3.6.1.4.1.2.3.51.2.2.21NodevpdInformation
1.3.6.1.4.1.2.3.51.2.2.21.1NodechassisVpd
1.3.6.1.4.1.2.3.51.2.2.21.1.1NodebladeCenterVpd
1.3.6.1.4.1.2.3.51.2.2.21.1.1.1ScalarbladeCenterVpdMachineTyperead-writemandatoryMachine type VPD information (from System BIOS). This field must be four alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.2ScalarbladeCenterVpdMachineModelread-writemandatoryMachine model VPD information (from System BIOS). This field must be three alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.3ScalarbladeCenterSerialNumberread-writemandatoryMachine serial number VPD information (from System BIOS). This field must be seven alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.4ScalarbladeCenterUUIDread-writemandatoryMachine UUID (Universal Unique ID information) (from System BIOS). This field must be 32 alpha numeric characters.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.5ScalarbladeCenterManufacturingIdread-onlymandatoryMachine chassis manufacturing ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.6ScalarbladeCenterHardwareRevisionread-onlymandatoryMachine chassis hardware revision. If a hardware revision is programmed in the OEM VPD area for this component, then the HardwareRevisionString version of this…
1.3.6.1.4.1.2.3.51.2.2.21.1.1.7ScalarbladeCenterFruNumberread-onlymandatoryMachine chassis FRU number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.8ScalarbladeCenterManufDateread-onlymandatoryMachine chassis manufacture date.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.9ScalarbladeCenterPartNumberread-onlymandatoryMachine chassis part number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.10ScalarbladeCenterFruSerialread-onlymandatoryMachine chassis FRU serial number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.11ScalarbladeCenterManufacturingIDNumberread-onlymandatoryMachine chassis manufacturer ID Number.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.12ScalarbladeCenterProductIdread-onlymandatoryMachine chassis product ID.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.13ScalarbladeCenterSubManufacturerIdread-onlymandatoryMachine chassis subsystem manufacturer.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.14ScalarbladeCenterCleiread-onlymandatoryMachine chassis Common Language Equipment Identification (CLEI).
1.3.6.1.4.1.2.3.51.2.2.21.1.1.15ScalarbladeCenterDirectSerialAttachread-onlymandatoryPresence of the Direct Serial Attach Module. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.1.1.16ScalarbladeCenterHardwareRevisionStringread-onlymandatoryMachine chassis hardware revision in string format. If a hardware revision is programmed in the OEM VPD area for this component, then this MIB object should be…
1.3.6.1.4.1.2.3.51.2.2.21.2NodemmHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.2.1TablemmHardwareVpdTablenot-accessiblemandatoryTable of the management module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1RowmmHardwareVpdEntrynot-accessiblemandatoryManagement module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.1ColumnmmHardwareVpdIndexread-onlymandatoryManagement module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.2ColumnmmHardwareVpdBayNumberread-onlymandatoryManagement module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.3ColumnmmHardwareVpdManufacturingIdread-onlymandatoryManagement module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.4ColumnmmHardwareVpdFruNumberread-onlymandatoryManagement module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.5ColumnmmHardwareVpdHardwareRevisionread-onlymandatoryManagement module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed i…
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.6ColumnmmHardwareVpdUuidread-onlymandatoryManagement module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.7ColumnmmHardwareVpdManufDateread-onlymandatoryManagement module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.8ColumnmmHardwareVpdPartNumberread-onlymandatoryManagement module hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.9ColumnmmHardwareVpdFruSerialread-onlymandatoryManagement module hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.10ColumnmmHardwareVpdManufacturingIDNumberread-onlymandatoryManagement module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.11ColumnmmHardwareVpdProductIdread-onlymandatoryManagement module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.12ColumnmmHardwareVpdSubManufacturerIdread-onlymandatoryManagement module hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.13ColumnmmHardwareVpdCleiread-onlymandatoryManagement module hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.1.1.14ColumnmmHardwareVpdHardwareRevisionStringread-onlymandatoryManagement module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revisio…
1.3.6.1.4.1.2.3.51.2.2.21.2.2TablemmInpHardwareVpdTablenot-accessiblemandatoryTable of the management module interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is …
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1RowmmInpHardwareVpdEntrynot-accessiblemandatoryManagement module Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.1ColumnmmInpHardwareVpdIndexread-onlymandatoryManagement module Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.2ColumnmmInpHardwareVpdBayNumberread-onlymandatoryManagement module Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for Blade…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.3ColumnmmInpHardwareVpdManufacturingIdread-onlymandatoryManagement module Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.4ColumnmmInpHardwareVpdFruNumberread-onlymandatoryManagement module Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for Blade…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.5ColumnmmInpHardwareVpdHardwareRevisionread-onlymandatoryManagement module Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is fo…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.6ColumnmmInpHardwareVpdUuidread-onlymandatoryManagement module Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.7ColumnmmInpHardwareVpdManufDateread-onlymandatoryManagement module Interposer hardware VPD manufacture date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.8ColumnmmInpHardwareVpdPartNumberread-onlymandatoryManagement module Interposer hardware VPD Part number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for Blad…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.9ColumnmmInpHardwareVpdFruSerialread-onlymandatoryManagement module Interposer hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is fo…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.10ColumnmmInpHardwareVpdManufacturingIDNumberread-onlymandatoryManagement module Interposer hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.11ColumnmmInpHardwareVpdProductIdread-onlymandatoryManagement module Interposer hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.12ColumnmmInpHardwareVpdSubManufacturerIdread-onlymandatoryManagement module Interposer hardware VPD subsystem manufacturer. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.13ColumnmmInpHardwareVpdCleiread-onlymandatoryManagement module Interposer hardware VPD Common Language Equipment Identification (CLEI). For consistent results, view as a table and not as individual entrie…
1.3.6.1.4.1.2.3.51.2.2.21.2.2.1.14ColumnmmInpHardwareVpdHardwareRevisionStringread-onlymandatoryManagement module Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This…
1.3.6.1.4.1.2.3.51.2.2.21.3NodemmFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.3.1TablemmMainApplVpdTablenot-accessiblemandatoryTable of MM Firmware VPD.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1RowmmMainApplVpdEntrynot-accessiblemandatoryMM Firmware VPD entry.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.1ColumnmmMainApplVpdIndexread-onlymandatoryFirmware VPD index.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.2ColumnmmMainApplVpdNameread-onlymandatoryFirmware VPD name description. 'AMM firmware' indicates the running firmware of the MM. 'AMM firmware (pending restart)' indicates the flashed firmware of the …
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.3ColumnmmMainApplVpdBuildIdread-onlymandatoryFirmware VPD build identification.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.4ColumnmmMainApplVpdRevisonNumberread-onlymandatoryFirmware VPD revision number.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.5ColumnmmMainApplVpdFilenameread-onlymandatoryFirmware VPD file name.
1.3.6.1.4.1.2.3.51.2.2.21.3.1.1.6ColumnmmMainApplVpdBuildDateread-onlymandatoryFirmware VPD build date.
1.3.6.1.4.1.2.3.51.2.2.21.3.2TablemmBootROMVpdTablenot-accessibledeprecatedTable of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1RowmmBootROMVpdEntrynot-accessibledeprecatedMM Firmware VPD entry. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.1ColumnmmBootROMVpdIndexread-onlydeprecatedFirmware VPD index. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.2ColumnmmBootROMVpdNameread-onlydeprecatedFirmware VPD name description. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.3ColumnmmBootROMVpdBuildIdread-onlydeprecatedFirmware VPD build identification. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.4ColumnmmBootROMVpdRevisonNumberread-onlydeprecatedFirmware VPD revision number. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.5ColumnmmBootROMVpdFilenameread-onlydeprecatedFirmware VPD file name. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.2.1.6ColumnmmBootROMVpdBuildDateread-onlydeprecatedFirmware VPD build date. NOTE: This MIB object is for MM only. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3TablemmRemoteControlVpdTablenot-accessibledeprecatedTable of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1RowmmRemoteControlVpdEntrynot-accessibledeprecatedMM Firmware VPD entry. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.1ColumnmmRemoteControlVpdIndexread-onlydeprecatedFirmware VPD index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.2ColumnmmRemoteControlVpdNameread-onlydeprecatedFirmware VPD name description. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.3ColumnmmRemoteControlVpdBuildIdread-onlydeprecatedFirmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.4ColumnmmRemoteControlVpdRevisonNumberread-onlydeprecatedFirmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.5ColumnmmRemoteControlVpdFilenameread-onlydeprecatedFirmware VPD file name. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.3.1.6ColumnmmRemoteControlVpdBuildDateread-onlydeprecatedFirmware VPD build date. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4TablemmPS2toUSBConvVpdTablenot-accessibledeprecatedTable of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1RowmmPS2toUSBConvVpdEntrynot-accessibledeprecatedMM Firmware VPD entry. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.1ColumnmmPS2toUSBConvVpdIndexread-onlydeprecatedFirmware VPD index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.2ColumnmmPS2toUSBConvVpdNameread-onlydeprecatedFirmware VPD name description. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.3ColumnmmPS2toUSBConvVpdBuildIdread-onlydeprecatedFirmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.4ColumnmmPS2toUSBConvVpdRevisonNumberread-onlydeprecatedFirmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.5ColumnmmPS2toUSBConvVpdFilenameread-onlydeprecatedFirmware VPD file name. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.4.1.6ColumnmmPS2toUSBConvVpdBuildDateread-onlydeprecatedFirmware VPD build date. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5TablemmToUSBIntfVpdTablenot-accessibledeprecatedTable of MM Firmware VPD. NOTE: This MIB object is for MM only. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1RowmmToUSBIntfVpdEntrynot-accessibledeprecatedMM Firmware VPD entry. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.1ColumnmmToUSBIntfVpdIndexread-onlydeprecatedFirmware VPD index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.2ColumnmmToUSBIntfVpdNameread-onlydeprecatedFirmware VPD name description. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.3ColumnmmToUSBIntfVpdBuildIdread-onlydeprecatedFirmware VPD build identification. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.4ColumnmmToUSBIntfVpdRevisonNumberread-onlydeprecatedFirmware VPD revision number. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.5ColumnmmToUSBIntfVpdFilenameread-onlydeprecatedFirmware VPD file name. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.3.5.1.6ColumnmmToUSBIntfVpdBuildDateread-onlydeprecatedFirmware VPD build date. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.2.21.4NodebladeHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.4.1TablebladeHardwareVpdTablenot-accessiblemandatoryTable of VPD information for the blade hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1RowbladeHardwareVpdEntrynot-accessiblemandatoryBlade hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.1ColumnbladeHardwareVpdIndexread-onlymandatoryBlade hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.2ColumnbladeHardwareVpdBayNumberread-onlymandatoryBlade hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.3ColumnbladeHardwareVpdManufacturingIdread-onlymandatoryBlade hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.4ColumnbladeHardwareVpdFruNumberread-onlymandatoryBlade hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.5ColumnbladeHardwareVpdHardwareRevisionread-onlymandatoryBlade hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM VP…
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.6ColumnbladeHardwareVpdSerialNumberread-onlymandatoryBlade hardware VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.7ColumnbladeHardwareVpdMachineTyperead-onlymandatoryBlade hardware VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.8ColumnbladeHardwareVpdUuidread-onlymandatoryBlade hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.9ColumnbladeHardwareVpdManufDateread-onlymandatoryBlade hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.10ColumnbladeHardwareVpdPartNumberread-onlymandatoryBlade hardware VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.11ColumnbladeHardwareVpdFruSerialread-onlymandatoryBlade hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.12ColumnbladeHardwareVpdMachineModelread-onlymandatoryBlade hardware VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.13ColumnbladeHardwareVpdManufacturingIDNumberread-onlymandatoryBlade hardware VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.14ColumnbladeHardwareVpdProductIdread-onlymandatoryBlade hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.15ColumnbladeHardwareVpdSubManufacturerIdread-onlymandatoryBlade hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.16ColumnbladeHardwareVpdCleiread-onlymandatoryBlade hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.17ColumnbladeHardwareVpdHardwareRevisionStringread-onlymandatoryBlade hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is program…
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.20ColumnbladeDaughterVpdCardTyperead-onlymandatoryBlade expansion card (daughter card) VPD type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.21ColumnbladeDaughterVpdManufacturingIdread-onlymandatoryBlade expansion card (daughter card) VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.22ColumnbladeDaughterVpdFruNumberread-onlymandatoryBlade expansion card (daughter card) VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.23ColumnbladeDaughterVpdHardwareRevisionread-onlymandatoryBlade expansion card (daughter card) VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is pr…
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.24ColumnbladeDaughterVpdSerialNumberread-onlymandatoryBlade expansion card (daughter card) VPD Serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.25ColumnbladeDaughterVpdMachineTyperead-onlymandatoryBlade expansion card (daughter card) VPD Machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.26ColumnbladeDaughterVpdUuidread-onlymandatoryBlade expansion card (daughter card) VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.27ColumnbladeDaughterVpdManufDateread-onlymandatoryBlade expansion card (daughter card) VPD Manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.28ColumnbladeDaughterVpdPartNumberread-onlymandatoryBlade expansion card (daughter card) VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.29ColumnbladeDaughterVpdFruSerialread-onlymandatoryBlade expansion card (daughter card) VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.30ColumnbladeDaughterVpdManufacturingIDNumberread-onlymandatoryBlade expansion card (daughter card) VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.31ColumnbladeDaughterVpdProductIdread-onlymandatoryBlade expansion card (daughter card) VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.32ColumnbladeDaughterVpdSubManufacturerIdread-onlymandatoryBlade expansion card (daughter card) VPD subsystem manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.33ColumnbladeDaughterVpdCleiread-onlymandatoryBlade expansion card (daughter card) VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.1.1.34ColumnbladeDaughterVpdHardwareRevisionStringread-onlymandatoryBlade expansion card (daughter card) VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardwa…
1.3.6.1.4.1.2.3.51.2.2.21.4.2TablebladeMACAddressVpdTablenot-accessiblemandatoryTable of MAC addresses of the blade and its expansion cards (daughter cards). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1RowbladeMACAddressVpdEntrynot-accessiblemandatoryBlade MAC address entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.1ColumnbladeMACAddressVpdIndexread-onlymandatoryBlade index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.2ColumnbladeMACAddress1Vpdread-onlymandatoryBlade MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.3ColumnbladeMACAddress2Vpdread-onlymandatoryBlade MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.4ColumnbladeMACAddress3Vpdread-onlymandatoryBlade MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.5ColumnbladeMACAddress4Vpdread-onlymandatoryBlade MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.6ColumnbladeMACAddress5Vpdread-onlymandatoryBlade MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.7ColumnbladeMACAddress6Vpdread-onlymandatoryBlade MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.8ColumnbladeMACAddress7Vpdread-onlymandatoryBlade MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.9ColumnbladeMACAddress8Vpdread-onlymandatoryBlade MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.10ColumnbladeDaughterCard1MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.11ColumnbladeDaughterCard1MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.12ColumnbladeDaughterCard1MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.13ColumnbladeDaughterCard1MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.14ColumnbladeDaughterCard1MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.15ColumnbladeDaughterCard1MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.16ColumnbladeDaughterCard1MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.17ColumnbladeDaughterCard1MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.18ColumnbladeDaughterCard2MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.19ColumnbladeDaughterCard2MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.20ColumnbladeDaughterCard2MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.21ColumnbladeDaughterCard2MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.22ColumnbladeDaughterCard2MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.23ColumnbladeDaughterCard2MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.24ColumnbladeDaughterCard2MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.25ColumnbladeDaughterCard2MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 2 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.26ColumnbladeDaughterCard3MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.27ColumnbladeDaughterCard3MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.28ColumnbladeDaughterCard3MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.29ColumnbladeDaughterCard3MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.30ColumnbladeDaughterCard3MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.31ColumnbladeDaughterCard3MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.32ColumnbladeDaughterCard3MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.33ColumnbladeDaughterCard3MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 3 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.34ColumnbladeDaughterCard4MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.35ColumnbladeDaughterCard4MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.36ColumnbladeDaughterCard4MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.37ColumnbladeDaughterCard4MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.38ColumnbladeDaughterCard4MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.39ColumnbladeDaughterCard4MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.40ColumnbladeDaughterCard4MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.41ColumnbladeDaughterCard4MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 4 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.42ColumnbladeDaughterCard5MACAddress1Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.43ColumnbladeDaughterCard5MACAddress2Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.44ColumnbladeDaughterCard5MACAddress3Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.45ColumnbladeDaughterCard5MACAddress4Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.46ColumnbladeDaughterCard5MACAddress5Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.47ColumnbladeDaughterCard5MACAddress6Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.48ColumnbladeDaughterCard5MACAddress7Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.49ColumnbladeDaughterCard5MACAddress8Vpdread-onlymandatoryBlade expansion card (daughter card) 5 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.100ColumnbladeHSDaughterCard1MACAddress1Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.101ColumnbladeHSDaughterCard1MACAddress2Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.102ColumnbladeHSDaughterCard1MACAddress3Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.103ColumnbladeHSDaughterCard1MACAddress4Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.104ColumnbladeHSDaughterCard1MACAddress5Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.105ColumnbladeHSDaughterCard1MACAddress6Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.106ColumnbladeHSDaughterCard1MACAddress7Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.107ColumnbladeHSDaughterCard1MACAddress8Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.108ColumnbladeHSDaughterCard1MACAddress9Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 9. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.109ColumnbladeHSDaughterCard1MACAddress10Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 10. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.110ColumnbladeHSDaughterCard1MACAddress11Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 11. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.111ColumnbladeHSDaughterCard1MACAddress12Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 12. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.112ColumnbladeHSDaughterCard1MACAddress13Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 13. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.113ColumnbladeHSDaughterCard1MACAddress14Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 14. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.114ColumnbladeHSDaughterCard1MACAddress15Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 15. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.115ColumnbladeHSDaughterCard1MACAddress16Vpdread-onlymandatoryBlade high speed expansion card (daughter card) 1 MAC address 16. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.164ColumnbladeSideCardMACAddress1Vpdread-onlymandatoryBlade side card MAC address 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.165ColumnbladeSideCardMACAddress2Vpdread-onlymandatoryBlade side card MAC address 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.166ColumnbladeSideCardMACAddress3Vpdread-onlymandatoryBlade side card MAC address 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.167ColumnbladeSideCardMACAddress4Vpdread-onlymandatoryBlade side card MAC address 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.168ColumnbladeSideCardMACAddress5Vpdread-onlymandatoryBlade side card MAC address 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.169ColumnbladeSideCardMACAddress6Vpdread-onlymandatoryBlade side card MAC address 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.170ColumnbladeSideCardMACAddress7Vpdread-onlymandatoryBlade side card MAC address 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.2.1.171ColumnbladeSideCardMACAddress8Vpdread-onlymandatoryBlade side card MAC address 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3TablebladeExpBoardVpdTablenot-accessiblemandatoryTable of VPD information for the blade expansion board components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1RowbladeExpBoardVpdEntrynot-accessiblemandatoryBlade expansion board VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.1ColumnbladeExpBoardVpdIndexread-onlymandatoryBlade expansion board VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.2ColumnbladeExpBoardVpdBayNumberread-onlymandatoryBlade expansion board VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.3ColumnbladeExpBoardVpdManufacturingIdread-onlymandatoryBlade expansion board VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.4ColumnbladeExpBoardVpdFruNumberread-onlymandatoryBlade expansion board VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.5ColumnbladeExpBoardVpdHardwareRevisionread-onlymandatoryBlade expansion board VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the…
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.6ColumnbladeExpBoardVpdSerialNumberread-onlymandatoryBlade expansion board VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.7ColumnbladeExpBoardVpdMachineTyperead-onlymandatoryBlade expansion board VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.8ColumnbladeExpBoardVpdUuidread-onlymandatoryBlade expansion board VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.9ColumnbladeExpBoardVpdManufDateread-onlymandatoryBlade expansion board VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.10ColumnbladeExpBoardVpdPartNumberread-onlymandatoryBlade expansion board VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.11ColumnbladeExpBoardVpdFruSerialread-onlymandatoryBlade expansion board VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.12ColumnbladeExpBoardVpdMachineModelread-onlymandatoryBlade expansion board VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.13ColumnbladeExpBoardVpdManufacturingIDNumberread-onlymandatoryBlade expansion board VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.14ColumnbladeExpBoardVpdProductIdread-onlymandatoryBlade expansion board VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.15ColumnbladeExpBoardVpdSubManufacturerIdread-onlymandatoryBlade expansion board VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.16ColumnbladeExpBoardVpdCleiread-onlymandatoryBlade expansion board VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.19ColumnbladeExpBoardVpdBladeBayNumberread-onlymandatoryBlade bay number of the blade expansion board. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.20ColumnbladeExpBoardVpdCardTyperead-onlymandatoryBlade expansion board VPD type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.21ColumnbladeExpBoardVpdCardSubTyperead-onlymandatoryBlade expansion board VPD subtype. Describes the expansion board type with more granularity. bse1,bse2,bse3 = Blade Storage Expansion (1st, 2nd, and 3rd Genera…
1.3.6.1.4.1.2.3.51.2.2.21.4.3.1.22ColumnbladeExpBoardVpdHardwareRevisionStringread-onlymandatoryBlade expansion board VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is …
1.3.6.1.4.1.2.3.51.2.2.21.4.4TablebladeSideCardVpdTablenot-accessiblemandatoryTable of VPD information for the blade side card components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1RowbladeSideCardVpdEntrynot-accessiblemandatoryBlade side card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.1ColumnbladeSideCardVpdIndexread-onlymandatoryBlade side card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.2ColumnbladeSideCardVpdBayNumberread-onlymandatoryBlade side card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.3ColumnbladeSideCardVpdManufacturingIdread-onlymandatoryBlade side card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.4ColumnbladeSideCardVpdFruNumberread-onlymandatoryBlade side card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.5ColumnbladeSideCardVpdHardwareRevisionread-onlymandatoryBlade side card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM V…
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.6ColumnbladeSideCardVpdSerialNumberread-onlymandatoryBlade side card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.7ColumnbladeSideCardVpdMachineTyperead-onlymandatoryBlade side card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.8ColumnbladeSideCardVpdUuidread-onlymandatoryBlade side card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.9ColumnbladeSideCardVpdManufDateread-onlymandatoryBlade side card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.10ColumnbladeSideCardVpdPartNumberread-onlymandatoryBlade side card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.11ColumnbladeSideCardVpdFruSerialread-onlymandatoryBlade side card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.12ColumnbladeSideCardVpdMachineModelread-onlymandatoryBlade side card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.13ColumnbladeSideCardVpdManufacturingIDNumberread-onlymandatoryBlade side card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.14ColumnbladeSideCardVpdProductIdread-onlymandatoryBlade side card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.15ColumnbladeSideCardVpdSubManufacturerIdread-onlymandatoryBlade side card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.16ColumnbladeSideCardVpdCleiread-onlymandatoryBlade side card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.19ColumnbladeSideCardVpdBladeBayNumberread-onlymandatoryBlade bay number of the blade side card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.4.1.20ColumnbladeSideCardVpdHardwareRevisionStringread-onlymandatoryBlade side card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is progra…
1.3.6.1.4.1.2.3.51.2.2.21.4.5TablebladeExpCardVpdTablenot-accessiblemandatoryTable of VPD information for the blade expansion card components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1RowbladeExpCardVpdEntrynot-accessiblemandatoryBlade expansion card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.1ColumnbladeExpCardVpdIndexread-onlymandatoryBlade expansion card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.2ColumnbladeExpCardVpdBayNumberread-onlymandatoryBlade expansion card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.3ColumnbladeExpCardVpdManufacturingIdread-onlymandatoryBlade expansion card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.4ColumnbladeExpCardVpdFruNumberread-onlymandatoryBlade expansion card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.5ColumnbladeExpCardVpdHardwareRevisionread-onlymandatoryBlade expansion card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the …
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.6ColumnbladeExpCardVpdSerialNumberread-onlymandatoryBlade expansion card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.7ColumnbladeExpCardVpdMachineTyperead-onlymandatoryBlade expansion card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.8ColumnbladeExpCardVpdUuidread-onlymandatoryBlade expansion card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.9ColumnbladeExpCardVpdManufDateread-onlymandatoryBlade expansion card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.10ColumnbladeExpCardVpdPartNumberread-onlymandatoryBlade expansion card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.11ColumnbladeExpCardVpdFruSerialread-onlymandatoryBlade expansion card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.12ColumnbladeExpCardVpdMachineModelread-onlymandatoryBlade expansion card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.13ColumnbladeExpCardVpdManufacturingIDNumberread-onlymandatoryBlade expansion card VPD Manufacturer ID Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.14ColumnbladeExpCardVpdProductIdread-onlymandatoryBlade expansion card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.15ColumnbladeExpCardVpdSubManufacturerIdread-onlymandatoryBlade expansion card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.16ColumnbladeExpCardVpdCleiread-onlymandatoryBlade expansion card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.19ColumnbladeExpCardVpdBladeBayNumberread-onlymandatoryBlade bay number of the blade expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.21ColumnbladeExpCardVpdCardTypeInforead-onlymandatoryBlade expansion card (daughter card) VPD type code that describes the expansion card. For consistent results, view as a table and not as individual entries. NO…
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.22ColumnbladeExpCardVpdHighSpeedread-onlymandatoryBlade expansion card (daughter card) VPD high speed that indicates whether the expansion card is high speed or not. For consistent results, view as a table and…
1.3.6.1.4.1.2.3.51.2.2.21.4.5.1.23ColumnbladeExpCardVpdHardwareRevisionStringread-onlymandatoryBlade expansion card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is p…
1.3.6.1.4.1.2.3.51.2.2.21.4.6TablebladecKVMCardVpdTablenot-accessiblemandatoryTable of VPD information for the blade concurrent keyboard, video, and mouse (cKVM) card components. For consistent results, view as a table and not as individ…
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1RowbladecKVMCardVpdEntrynot-accessiblemandatoryBlade concurrent keyboard, video, and mouse (cKVM) card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.1ColumnbladecKVMCardVpdIndexread-onlymandatoryBlade concurrent keyboard mouse video (cKVM) card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.2ColumnbladecKVMCardVpdBayNumberread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.3ColumnbladecKVMCardVpdManufacturingIdread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.4ColumnbladecKVMCardVpdFruNumberread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.5ColumnbladecKVMCardVpdHardwareRevisionread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware r…
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.6ColumnbladecKVMCardVpdSerialNumberread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.7ColumnbladecKVMCardVpdMachineTyperead-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.8ColumnbladecKVMCardVpdUuidread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.9ColumnbladecKVMCardVpdManufDateread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.10ColumnbladecKVMCardVpdPartNumberread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.11ColumnbladecKVMCardVpdFruSerialread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.12ColumnbladecKVMCardVpdMachineModelread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.13ColumnbladecKVMCardVpdManufacturingIDNumberread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.14ColumnbladecKVMCardVpdProductIdread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.15ColumnbladecKVMCardVpdSubManufacturerIdread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.16ColumnbladecKVMCardVpdCleiread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individua…
1.3.6.1.4.1.2.3.51.2.2.21.4.6.1.17ColumnbladecKVMCardVpdHardwareRevisionStringread-onlymandatoryBlade concurrent keyboard video mouse (cKVM) card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries…
1.3.6.1.4.1.2.3.51.2.2.21.4.7TablebladeAndExpCardWwnGuidVpdTablenot-accessiblemandatoryTable of World Wide Names (WWN), Global Unique IDs (GUID) and Serial Attach SCSI IDs (SAS) of the blade server and its expansion cards (daughter cards). For co…
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1RowbladeAndExpCardWwnGuidVpdEntrynot-accessiblemandatoryBlade WWN/GUID entries. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.1ColumnbladeAndExpCardWwnGuidVpdIndexread-onlymandatoryBlade or expansion card index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.2ColumnbladeAndExpCardWwnGuidVpdBayNumberread-onlymandatoryBlade or expansion card VPD bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.3ColumnbladeAndExpCardWwnGuidVpdNameread-onlymandatoryThe name of the blade or expansion card. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.4ColumnbladeAndExpCardWwnGuidVpdBladeBayNumberread-onlymandatoryFor expansion cards, it's the blade bay number of the blade expansion card. For blades, it's the bay number of the blade. For consistent results, view as a tab…
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.5ColumnbladeAndExpCardWwnGuidVpdTyperead-onlymandatoryBlade or expansion card WWN/GUID/SAS Type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.6ColumnbladeAndExpCardWwnGuidVpd1read-onlymandatoryBlade or expansion card WWN/GUID 1. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.7ColumnbladeAndExpCardWwnGuidVpd2read-onlymandatoryBlade or expansion card WWN/GUID 2. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.8ColumnbladeAndExpCardWwnGuidVpd3read-onlymandatoryBlade or expansion card WWN/GUID 3. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.9ColumnbladeAndExpCardWwnGuidVpd4read-onlymandatoryBlade or expansion card WWN/GUID 4. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.10ColumnbladeAndExpCardWwnGuidVpd5read-onlymandatoryBlade or expansion card WWN/GUID 5. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.11ColumnbladeAndExpCardWwnGuidVpd6read-onlymandatoryBlade or expansion card WWN/GUID 6. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.12ColumnbladeAndExpCardWwnGuidVpd7read-onlymandatoryBlade or expansion card WWN/GUID 7. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.7.1.13ColumnbladeAndExpCardWwnGuidVpd8read-onlymandatoryBlade or expansion card WWN/GUID 8. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8TablebladeManagementCardVpdTablenot-accessiblemandatoryTable of VPD information for the blade management card component. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1RowbladeManagementCardVpdEntrynot-accessiblemandatoryBlade management card VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.1ColumnbladeManagementCardVpdIndexread-onlymandatoryBlade management card VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.2ColumnbladeManagementCardVpdBayNumberread-onlymandatoryBlade management card VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.3ColumnbladeManagementCardVpdManufacturingIdread-onlymandatoryBlade management card VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.4ColumnbladeManagementCardVpdFruNumberread-onlymandatoryBlade management card VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.5ColumnbladeManagementCardVpdHardwareRevisionread-onlymandatoryBlade management card VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the…
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.6ColumnbladeManagementCardVpdSerialNumberread-onlymandatoryBlade management card VPD serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.7ColumnbladeManagementCardVpdMachineTyperead-onlymandatoryBlade management card VPD machine type. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.8ColumnbladeManagementCardVpdUuidread-onlymandatoryBlade management card VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.9ColumnbladeManagementCardVpdManufDateread-onlymandatoryBlade management card VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.10ColumnbladeManagementCardVpdPartNumberread-onlymandatoryBlade management card VPD Part number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.11ColumnbladeManagementCardVpdFruSerialread-onlymandatoryBlade management card VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.12ColumnbladeManagementCardVpdMachineModelread-onlymandatoryBlade management card VPD machine model. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.13ColumnbladeManagementCardVpdManufacturingIDNumberread-onlymandatoryBlade management card VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.14ColumnbladeManagementCardVpdProductIdread-onlymandatoryBlade management card VPD Product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.15ColumnbladeManagementCardVpdSubManufacturerIdread-onlymandatoryBlade management card VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.16ColumnbladeManagementCardVpdCleiread-onlymandatoryBlade management card VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.4.8.1.17ColumnbladeManagementCardVpdHardwareRevisionStringread-onlymandatoryBlade management card VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is …
1.3.6.1.4.1.2.3.51.2.2.21.5NodebladeFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.5.1TablebladeBiosVPDTablenot-accessiblemandatoryTable of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1RowbladeBiosVPDEntrynot-accessiblemandatoryBlade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.1ColumnbladeBiosVpdIndexread-onlymandatoryBlade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.2ColumnbladeBiosVpdIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.3ColumnbladeBiosVpdExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.4ColumnbladeBiosVpdPowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.5ColumnbladeBiosVpdNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.6ColumnbladeBiosVpdBuildIdread-onlymandatoryThe build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.7ColumnbladeBiosVpdRevisionread-onlymandatoryThe revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.8ColumnbladeBiosVpdDateread-onlymandatoryThe date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.1.1.9ColumnbladeBiosVpdLevelStatusread-onlymandatoryThe level status of the blade bios firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID…
1.3.6.1.4.1.2.3.51.2.2.21.5.2TablebladeDiagsVPDTablenot-accessiblemandatoryTable of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1RowbladeDiagsVPDEntrynot-accessiblemandatoryBlade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.1ColumnbladeDiagsVpdIndexread-onlymandatoryBlade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.2ColumnbladeDiagsVpdIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.3ColumnbladeDiagsVpdExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.4ColumnbladeDiagsVpdPowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.5ColumnbladeDiagsVpdNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.6ColumnbladeDiagsVpdBuildIdread-onlymandatoryThe build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.7ColumnbladeDiagsVpdRevisionread-onlymandatoryThe revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.8ColumnbladeDiagsVpdDateread-onlymandatoryThe date of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.2.1.9ColumnbladeDiagsVpdLevelStatusread-onlymandatoryThe level status of the blade diagnostics firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware b…
1.3.6.1.4.1.2.3.51.2.2.21.5.3TablebladeSysMgmtProcVPDTablenot-accessiblemandatoryTable of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1RowbladeSysMgmtProcVPDEntrynot-accessiblemandatoryBlade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.1ColumnbladeSysMgmtProcVpdIndexread-onlymandatoryBlade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.2ColumnbladeSysMgmtProcVpdIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.3ColumnbladeSysMgmtProcVpdExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.4ColumnbladeSysMgmtProcVpdPowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.5ColumnbladeSysMgmtProcVpdNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.6ColumnbladeSysMgmtProcVpdBuildIdread-onlymandatoryThe build ID for the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.7ColumnbladeSysMgmtProcVpdRevisionread-onlymandatoryThe revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.3.1.8ColumnbladeSysMgmtProcVpdLevelStatusread-onlymandatoryThe level status of the blade system management processor firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the…
1.3.6.1.4.1.2.3.51.2.2.21.5.4TablebladecKVMVPDTablenot-accessiblemandatoryTable of blade firmware vital product data (VPD) information.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1RowbladecKVMVPDEntrynot-accessiblemandatoryBlade firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.1ColumnbladecKVMVpdIndexread-onlymandatoryBlade firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.2ColumnbladecKVMVpdIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.3ColumnbladecKVMVpdExistsread-onlymandatoryIndicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.4ColumnbladecKVMVpdPowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.5ColumnbladecKVMVpdNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.2.21.5.4.1.7ColumnbladecKVMVpdRevisionread-onlymandatoryThe revision of the blade firmware.
1.3.6.1.4.1.2.3.51.2.2.21.5.5NodebladeFWBuildIDs
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1TablebladeFWBuildIDTablenot-accessiblemandatoryTable of Blade Firmware Build ID entries information.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1RowbladeFWBuildIDEntrynot-accessiblemandatoryBlade Firmware Build ID table entry
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.1ColumnbladeFWBuildIDIndexread-onlymandatoryThe index number of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.2ColumnbladeFWBuildMfgread-writemandatoryThe Manufacturer property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.3ColumnbladeFWBuildMTread-writemandatoryThe Machine Type property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.4ColumnbladeFWBuildFWTyperead-writemandatoryThe Firmware Type property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.5ColumnbladeFWBuildIDread-writemandatoryThe Build ID property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.1.1.6ColumnbladeFWBuildRevread-writemandatoryThe Build Revision property of one Build ID entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.2ScalarcreateBladeFWBuildIDswrite-onlymandatoryCreate one new Build ID List from current installed blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3NodeaddBladeFWBuildID
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.1ScalaraddBladeMfgread-writemandatoryAdd one Build ID entry into the Build ID List. This is to set Manufacturer property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.2ScalaraddBladeMtread-writemandatoryAdd one Build ID entry into the Build ID List. This is to set Machine Type property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.3ScalaraddBladeFtread-writemandatoryAdd one Build ID entry into the Build ID List. This is to set Firmware Type property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.4ScalaraddBladeBuildIDread-writemandatoryAdd one Build ID entry into the Build ID List. This is to set Build ID property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.5ScalaraddBladeBuildRevread-writemandatoryAdd one Build ID entry into the Build ID List. This is to set Build Revision property.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.3.6ScalarexeBladeAddingwrite-onlymandatoryAdd one Build ID entry into the Build ID List. This is to perform the adding action. NOTE: Value returned for the GET command is meaningless for this MIB objec…
1.3.6.1.4.1.2.3.51.2.2.21.5.5.4ScalarrmBladeFWBuildIDwrite-onlymandatoryRemove one Build ID entry from the Build ID List. The index of the Build ID entry in the list is required. NOTE: Value returned for the GET command is meaningl…
1.3.6.1.4.1.2.3.51.2.2.21.5.5.5ScalarrmAllBladeFWBuildIDswrite-onlymandatoryRemove all Build ID entries from the Build ID List. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.6ScalarbuildIDFileNameread-writemandatoryFile name of the Build ID list that will be used in import function.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.7ScalarbuildIDURINameread-writemandatoryContains the fully qualified remote location of the build ID list. Use buildIDFileName to specify the filename. A fully qualified remote location contains a su…
1.3.6.1.4.1.2.3.51.2.2.21.5.5.8ScalarbuildIDtftpIPread-writemandatoryIf importing/exporting via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The …
1.3.6.1.4.1.2.3.51.2.2.21.5.5.9ScalarimportBladeFWBuildIDswrite-onlymandatoryImport one Build ID List set by the buildIDFilename from a specific location set by buildIDServer.
1.3.6.1.4.1.2.3.51.2.2.21.5.5.10ScalarexportBladeFWBuildIDswrite-onlymandatoryExport the current Build ID List from the active AMM to a specific location set by buildIDServer. NOTE: Value returned for the GET command is meaningless for t…
1.3.6.1.4.1.2.3.51.2.2.21.5.5.11ScalarstatusBladeFWBuildIDsread-onlymandatoryGives the status message from the last import or export operation.
1.3.6.1.4.1.2.3.51.2.2.21.6NodesmHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.6.1TablesmHardwareVpdTablenot-accessiblemandatoryTable of the switch module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1RowsmHardwareVpdEntrynot-accessiblemandatorySwitch module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.1ColumnsmHardwareVpdIndexread-onlymandatorySwitch module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.2ColumnsmHardwareVpdBayNumberread-onlymandatorySwitch module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.3ColumnsmHardwareVpdManufacturingIdread-onlymandatorySwitch module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.4ColumnsmHardwareVpdFruNumberread-onlymandatorySwitch module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.5ColumnsmHardwareVpdHardwareRevisionread-onlymandatorySwitch module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in th…
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.8ColumnsmHardwareVpdUuidread-onlymandatorySwitch module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.9ColumnsmHardwareVpdManufDateread-onlymandatorySwitch module hardware VPD manufacture date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.10ColumnsmHardwareVpdPartNumberread-onlymandatorySwitch module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.11ColumnsmHardwareVpdFruSerialread-onlymandatorySwitch module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.12ColumnsmHardwareVpdManufacturingIDNumberread-onlymandatorySwitch module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.13ColumnsmHardwareVpdProductIdread-onlymandatorySwitch module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.14ColumnsmHardwareVpdSubManufacturerIdread-onlymandatorySwitch module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.15ColumnsmHardwareVpdCleiread-onlymandatorySwitch module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.16ColumnsmHardwareVpdWwnGuidread-onlymandatorySwitch module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.17ColumnsmHardwareVpdWwnGuidTyperead-onlymandatoryThe WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and not as individual en…
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.18ColumnsmHardwareVpdWidthread-onlymandatoryThe width of the switch module hardware. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.1.1.20ColumnsmHardwareVpdHardwareRevisionStringread-onlymandatorySwitch module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is…
1.3.6.1.4.1.2.3.51.2.2.21.6.2TablesmInpHardwareVpdTablenot-accessiblemandatoryTable of the switch interposer hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCe…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1RowsmInpHardwareVpdEntrynot-accessiblemandatorySwitch Interposer hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.1ColumnsmInpHardwareVpdIndexread-onlymandatorySwitch Interposer hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.2ColumnsmInpHardwareVpdBayNumberread-onlymandatorySwitch Interposer hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS o…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.3ColumnsmInpHardwareVpdManufacturingIdread-onlymandatorySwitch Interposer hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.4ColumnsmInpHardwareVpdFruNumberread-onlymandatorySwitch Interposer hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS o…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.5ColumnsmInpHardwareVpdHardwareRevisionread-onlymandatorySwitch Interposer hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCent…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.8ColumnsmInpHardwareVpdUuidread-onlymandatorySwitch Interposer hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.9ColumnsmInpHardwareVpdManufDateread-onlymandatorySwitch Interposer hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.10ColumnsmInpHardwareVpdPartNumberread-onlymandatorySwitch Interposer hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS …
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.11ColumnsmInpHardwareVpdFruSerialread-onlymandatorySwitch Interposer module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCent…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.12ColumnsmInpHardwareVpdManufacturingIDNumberread-onlymandatorySwitch Interposer module hardware VPD manufacturer ID Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is f…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.13ColumnsmInpHardwareVpdProductIdread-onlymandatorySwitch Interposer module hardware VPD product ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCent…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.14ColumnsmInpHardwareVpdSubManufacturerIdread-onlymandatorySwitch Interposer module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object i…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.15ColumnsmInpHardwareVpdCleiread-onlymandatorySwitch Interposer module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries. NOTE:…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.16ColumnsmInpHardwareVpdWwnGuidread-onlymandatorySwitch Interposer module hardware VPD World Wide Name or Global Unique ID. For consistent results, view as a table and not as individual entries. NOTE: This MI…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.17ColumnsmInpHardwareVpdWwnGuidTyperead-onlymandatoryThe Switch Interposer WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID or Serial Attach SCSI ID. For consistent results, view as a table and no…
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.18ColumnsmInpHardwareVpdWidthread-onlymandatoryThe width of the switch Interposer module hardware. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.19ColumnsmInpHardwareVpdNameread-onlymandatoryThe Switch Interposer Name. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HS only.
1.3.6.1.4.1.2.3.51.2.2.21.6.2.1.20ColumnsmInpHardwareVpdHardwareRevisionStringread-onlymandatorySwitch Interposer hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object…
1.3.6.1.4.1.2.3.51.2.2.21.7NodesmFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.7.1TablesmMainAppVpdTablenot-accessiblemandatorySwitch module main application VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1RowsmMainAppVpdEntrynot-accessiblemandatorySwitch module main application VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.1ColumnsmMainAppVpdIndexread-onlymandatorySwitch module main application VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.2ColumnsmMainAppVpdIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.3ColumnsmMainAppVpdExistsread-onlymandatoryIndicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.4ColumnsmMainAppVpdSwitchTyperead-onlymandatoryIndicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.5ColumnsmMainApp1VpdBuildIdread-onlymandatorySwitch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.6ColumnsmMainApp1VpdBuildDateread-onlymandatorySwitch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.7ColumnsmMainApp1VpdRevisionNumberread-onlymandatorySwitch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.8ColumnsmMainApp2VpdBuildIdread-onlymandatorySwitch module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.9ColumnsmMainApp2VpdBuildDateread-onlymandatorySwitch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.10ColumnsmMainApp2VpdRevisionNumberread-onlymandatorySwitch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.11ColumnsmMainApp3VpdBuildIdread-onlymandatoryI/O Module firmware build id.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.12ColumnsmMainApp3VpdBuildDateread-onlymandatoryI/O Module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.13ColumnsmMainApp3VpdRevisionNumberread-onlymandatoryI/O Module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.1.1.20ColumnsmMainAppVpdSwitchSubTyperead-onlymandatoryIndicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2TablesmBootRomVpdTablenot-accessiblemandatorySwitch module boot ROM VPD information table.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1RowsmBootRomVpdEntrynot-accessiblemandatorySwitch module boot ROM VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.1ColumnsmBootRomVpdIndexread-onlymandatorySwitch module boot ROM VPD entry index.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.2ColumnsmBootRomVpdIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.3ColumnsmBootRomVpdExistsread-onlymandatoryIndicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.4ColumnsmBootRomVpdSwitchTyperead-onlymandatoryIndicates the type of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.5ColumnsmBootRomVpdBuildIdread-onlymandatorySwitch module firmware build ID.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.6ColumnsmBootRomVpdBuildDateread-onlymandatorySwitch module firmware build date.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.7ColumnsmBootRomVpdRevisionNumberread-onlymandatorySwitch module firmware revision number.
1.3.6.1.4.1.2.3.51.2.2.21.7.2.1.8ColumnsmBootRomVpdSwitchSubTyperead-onlymandatoryIndicates the subtype of switch module installed.
1.3.6.1.4.1.2.3.51.2.2.21.8NodepmHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.8.1TablepmHardwareVpdTablenot-accessiblemandatoryTable of the power module hardware components. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1RowpmHardwareVpdEntrynot-accessiblemandatoryPower module hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.1ColumnpmHardwareVpdIndexread-onlymandatoryPower module hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.2ColumnpmHardwareVpdBayNumberread-onlymandatoryPower module hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.3ColumnpmHardwareVpdManufacturingIdread-onlymandatoryPower module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.4ColumnpmHardwareVpdFruNumberread-onlymandatoryPower module hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.5ColumnpmHardwareVpdHardwareRevisionread-onlymandatoryPower module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the…
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.8ColumnpmHardwareVpdUuidread-onlymandatoryPower module hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.9ColumnpmHardwareVpdManufDateread-onlymandatoryPower module hardware VPD Manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.10ColumnpmHardwareVpdPartNumberread-onlymandatoryPower module hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.11ColumnpmHardwareVpdFruSerialread-onlymandatoryPower module hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.12ColumnpmHardwareVpdManufacturingIDNumberread-onlymandatoryPower module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.13ColumnpmHardwareVpdProductIdread-onlymandatoryPower module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.14ColumnpmHardwareVpdSubManufacturerIdread-onlymandatoryPower module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.15ColumnpmHardwareVpdCleiread-onlymandatoryPower module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.8.1.1.16ColumnpmHardwareVpdHardwareRevisionStringread-onlymandatoryPower module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is …
1.3.6.1.4.1.2.3.51.2.2.21.9NodemtHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.9.3ScalarmtHardwareVpdManufacturingIdread-onlymandatoryMedia tray 1 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.4ScalarmtHardwareVpdFruNumberread-onlymandatoryMedia tray 1 hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.5ScalarmtHardwareVpdHardwareRevisionread-onlymandatoryMedia tray 1 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the…
1.3.6.1.4.1.2.3.51.2.2.21.9.8ScalarmtHardwareVpdUuidread-onlymandatoryMedia tray 1 hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.9ScalarmtHardwareVpdManufacturingIDNumberread-onlymandatoryMedia tray 1 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.10ScalarmtHardwareVpdProductIdread-onlymandatoryMedia tray 1 hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.11ScalarmtHardwareVpdSubManufacturerIdread-onlymandatoryMedia tray 1 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.12ScalarmtHardwareVpdCleiread-onlymandatoryMedia tray 1 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.13ScalarmtHardwareVpdCF1Capacityread-onlymandatoryMedia tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.14ScalarmtHardwareVpdCF2Capacityread-onlymandatoryMedia tray 1 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.9.15ScalarmtHardwareVpdBBU1read-onlymandatoryIndicates the presence of Battery Backup Unit 1. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.9.16ScalarmtHardwareVpdBBU2read-onlymandatoryIndicates the presence of Battery Backup Unit 2. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.9.17ScalarmtHardwareVpdHardwareRevisionStringread-onlymandatoryMedia tray 1 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is …
1.3.6.1.4.1.2.3.51.2.2.21.9.18ScalarmtHardwareVpdManufDateread-onlymandatoryMedia tray 1 hardware VPD Manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.9.19ScalarmtHardwareVpdPartNumberread-onlymandatoryMedia tray 1 hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.9.20ScalarmtHardwareVpdFruSerialread-onlymandatoryMedia tray 1 hardware VPD FRU Serial.
1.3.6.1.4.1.2.3.51.2.2.21.10Nodemt2HardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.10.3Scalarmt2HardwareVpdManufacturingIdread-onlymandatoryMedia tray 2 hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.4Scalarmt2HardwareVpdFruNumberread-onlymandatoryMedia tray 2 hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.5Scalarmt2HardwareVpdHardwareRevisionread-onlymandatoryMedia tray 2 hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the…
1.3.6.1.4.1.2.3.51.2.2.21.10.8Scalarmt2HardwareVpdUuidread-onlymandatoryMedia tray 2 hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.9Scalarmt2HardwareVpdManufacturingIDNumberread-onlymandatoryMedia tray 2 hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.10Scalarmt2HardwareVpdProductIdread-onlymandatoryMedia tray 2 hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.11Scalarmt2HardwareVpdSubManufacturerIdread-onlymandatoryMedia tray 2 hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.12Scalarmt2HardwareVpdCleiread-onlymandatoryMedia tray 2 hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.13Scalarmt2HardwareVpdCF1Capacityread-onlymandatoryMedia tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.14Scalarmt2HardwareVpdCF2Capacityread-onlymandatoryMedia tray 2 hardware VPD CompactFlash card capacity. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.10.17Scalarmt2HardwareVpdHardwareRevisionStringread-onlymandatoryMedia tray 2 hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is …
1.3.6.1.4.1.2.3.51.2.2.21.10.18Scalarmt2HardwareVpdManufDateread-onlymandatoryMedia tray 2 hardware VPD Manufacture Date.
1.3.6.1.4.1.2.3.51.2.2.21.10.19Scalarmt2HardwareVpdPartNumberread-onlymandatoryMedia tray 2 hardware VPD Part Number.
1.3.6.1.4.1.2.3.51.2.2.21.10.20Scalarmt2HardwareVpdFruSerialread-onlymandatoryMedia tray 2 hardware VPD FRU Serial.
1.3.6.1.4.1.2.3.51.2.2.21.12NodeblowerFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.12.1TableblowerControllerVPDTablenot-accessiblemandatoryTable of blower controller firmware vital product data (VPD) information. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1RowblowerControllerVPDEntrynot-accessiblemandatoryBlower controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.1ColumnblowerControllerVpdIndexread-onlymandatoryBlower controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.2ColumnblowerControllerVpdIdread-onlymandatoryThe numeric blower ID.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.3ColumnblowerControllerVpdExistsread-onlymandatoryIndicates whether the blower specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.12.1.1.7ColumnblowerControllerVpdRevisionread-onlymandatoryThe revision of the blower controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.13NodeblowerHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.13.1TableblowerHardwareVpdTablenot-accessiblemandatoryTable of the blower hardware components. For consistent results, view as a table and not as individual entries. NOTE: Blowers are also referred to as Chassis C…
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1RowblowerHardwareVpdEntrynot-accessiblemandatoryBlower hardware VPD entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.1ColumnblowerHardwareVpdIndexread-onlymandatoryBlower hardware VPD index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.2ColumnblowerHardwareVpdBayNumberread-onlymandatoryBlower hardware VPD Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.3ColumnblowerHardwareVpdManufacturingIdread-onlymandatoryBlower hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.4ColumnblowerHardwareVpdFruNumberread-onlymandatoryBlower hardware VPD FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.5ColumnblowerHardwareVpdHardwareRevisionread-onlymandatoryBlower hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. If a hardware revision is programmed in the OEM V…
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.8ColumnblowerHardwareVpdUuidread-onlymandatoryBlower hardware VPD UUID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.9ColumnblowerHardwareVpdManufDateread-onlymandatoryBlower hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.10ColumnblowerHardwareVpdPartNumberread-onlymandatoryBlower hardware VPD Part Number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.11ColumnblowerHardwareVpdFruSerialread-onlymandatoryBlower hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.12ColumnblowerHardwareVpdManufacturingIDNumberread-onlymandatoryBlower hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.13ColumnblowerHardwareVpdProductIdread-onlymandatoryBlower hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.14ColumnblowerHardwareVpdSubManufacturerIdread-onlymandatoryBlower hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.15ColumnblowerHardwareVpdCleiread-onlymandatoryBlower hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.13.1.1.16ColumnblowerHardwareVpdHardwareRevisionStringread-onlymandatoryBlower hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. If a hardware revision is progra…
1.3.6.1.4.1.2.3.51.2.2.21.14NodefanPackFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.14.1TablefanPackControllerVPDTablenot-accessiblemandatoryTable of fan pack controller firmware vital product data (VPD) information. NOTE: Fan packs are also referred to as Power Module Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1RowfanPackControllerVPDEntrynot-accessiblemandatoryFan Pack controller firmware VPD table entry
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.1ColumnfanPackControllerVpdIndexread-onlymandatoryFan Pack controller firmware VPD table index.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.2ColumnfanPackControllerVpdIdread-onlymandatoryThe numeric fan pack ID.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.3ColumnfanPackControllerVpdExistsread-onlymandatoryIndicates whether the fan pack specified exists or not.
1.3.6.1.4.1.2.3.51.2.2.21.14.1.1.7ColumnfanPackControllerVpdRevisionread-onlymandatoryThe revision of the fan pack controller firmware.
1.3.6.1.4.1.2.3.51.2.2.21.15NodetapHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.15.3ScalartapHardwareVpdManufacturingIdread-onlymandatoryTelco Alarm Panel hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.15.4ScalartapHardwareVpdFruNumberread-onlymandatoryTelco Alarm Panel hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT o…
1.3.6.1.4.1.2.3.51.2.2.21.15.5ScalartapHardwareVpdHardwareRevisionread-onlymandatoryTelco Alarm Panel hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCent…
1.3.6.1.4.1.2.3.51.2.2.21.15.8ScalartapHardwareVpdUuidread-onlymandatoryTelco Alarm Panel hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.15.9ScalartapHardwareVpdManufDateread-onlymandatoryTelco Alarm Panel hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.15.10ScalartapHardwareVpdPartNumberread-onlymandatoryTelco Alarm Panel hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT …
1.3.6.1.4.1.2.3.51.2.2.21.15.11ScalartapHardwareVpdFruSerialread-onlymandatoryTelco Alarm Panel hardware VPD FRU Serial. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT o…
1.3.6.1.4.1.2.3.51.2.2.21.15.12ScalartapHardwareVpdManufacturingIDNumberread-onlymandatoryTelco Alarm Panel hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.13ScalartapHardwareVpdProductIdread-onlymandatoryTelco Alarm Panel hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.14ScalartapHardwareVpdSubManufacturerIdread-onlymandatoryTelco Alarm Panel hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.15ScalartapHardwareVpdCleiread-onlymandatoryTelco Alarm Panel hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.15.16ScalartapHardwareVpdHardwareRevisionStringread-onlymandatoryTelco Alarm Panel hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object…
1.3.6.1.4.1.2.3.51.2.2.21.16NodencHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.16.1TablencHardwareVpdTablenot-accessibledeprecatedTable of the Network Clock hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter…
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1RowncHardwareVpdEntrynot-accessibledeprecatedNetwork Clock hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.1ColumnncHardwareVpdIndexread-onlydeprecatedNetwork Clock hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.2ColumnncHardwareVpdBayNumberread-onlydeprecatedNetwork Clock hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.3ColumnncHardwareVpdManufacturingIdread-onlydeprecatedNetwork Clock hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT…
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.4ColumnncHardwareVpdFruNumberread-onlydeprecatedNetwork Clock hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.5ColumnncHardwareVpdHardwareRevisionread-onlydeprecatedNetwork Clock hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter H…
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.8ColumnncHardwareVpdUuidread-onlydeprecatedNetwork Clock hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.9ColumnncHardwareVpdManufDateread-onlydeprecatedNetwork Clock hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT…
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.10ColumnncHardwareVpdPartNumberread-onlydeprecatedNetwork Clock hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.11ColumnncHardwareVpdFruSerialread-onlydeprecatedNetwork Clock hardware VPD FRU serial number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter H…
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.12ColumnncHardwareVpdManufacturingIDNumberread-onlydeprecatedNetwork Clock hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.13ColumnncHardwareVpdProductIdread-onlydeprecatedNetwork Clock hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.14ColumnncHardwareVpdSubManufacturerIdread-onlydeprecatedNetwork Clock hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.15ColumnncHardwareVpdCleiread-onlydeprecatedNetwork Clock hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.16.1.1.16ColumnncHardwareVpdHardwareRevisionStringread-onlydeprecatedNetwork Clock hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is …
1.3.6.1.4.1.2.3.51.2.2.21.17NodemxHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.17.1TablemxHardwareVpdTablenot-accessiblemandatoryTable of the Multiplexer Expansion Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is …
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1RowmxHardwareVpdEntrynot-accessiblemandatoryMultiplexer Expansion Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.1ColumnmxHardwareVpdIndexread-onlymandatoryMultiplexer Expansion Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCente…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.2ColumnmxHardwareVpdBayNumberread-onlymandatoryMultiplexer Expansion Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for Blade…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.3ColumnmxHardwareVpdManufacturingIdread-onlymandatoryMultiplexer Expansion Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.4ColumnmxHardwareVpdFruNumberread-onlymandatoryMultiplexer Expansion Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for Blade…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.5ColumnmxHardwareVpdHardwareRevisionread-onlymandatoryMultiplexer Expansion Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is fo…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.8ColumnmxHardwareVpdUuidread-onlymandatoryMultiplexer Expansion Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.9ColumnmxHardwareVpdManufDateread-onlymandatoryMultiplexer Expansion Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.10ColumnmxHardwareVpdPartNumberread-onlymandatoryMultiplexer Expansion Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for Blad…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.11ColumnmxHardwareVpdFruSerialread-onlymandatoryMultiplexer Expansion Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is fo…
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.12ColumnmxHardwareVpdManufacturingIDNumberread-onlymandatoryMultiplexer Expansion Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.13ColumnmxHardwareVpdProductIdread-onlymandatoryMultiplexer Expansion Module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.14ColumnmxHardwareVpdSubManufacturerIdread-onlymandatoryMultiplexer Expansion Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.15ColumnmxHardwareVpdCleiread-onlymandatoryMultiplexer Expansion Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.17.1.1.16ColumnmxHardwareVpdHardwareRevisionStringread-onlymandatoryMultiplexer Expansion Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This…
1.3.6.1.4.1.2.3.51.2.2.21.18NodestmHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.18.1TablestmHardwareVpdTablenot-accessiblemandatoryTable of the Storage Module hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1RowstmHardwareVpdEntrynot-accessiblemandatoryStorage Module hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.1ColumnstmHardwareVpdIndexread-onlymandatoryStorage Module hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.2ColumnstmHardwareVpdBayNumberread-onlymandatoryStorage Module hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.3ColumnstmHardwareVpdManufacturingIdread-onlymandatoryStorage Module hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.4ColumnstmHardwareVpdFruNumberread-onlymandatoryStorage Module hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.5ColumnstmHardwareVpdHardwareRevisionread-onlymandatoryStorage Module hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only. If…
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.8ColumnstmHardwareVpdUuidread-onlymandatoryStorage Module hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.9ColumnstmHardwareVpdManufDateread-onlymandatoryStorage Module hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.10ColumnstmHardwareVpdPartNumberread-onlymandatoryStorage Module hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.11ColumnstmHardwareVpdFruSerialread-onlymandatoryStorage Module hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.12ColumnstmHardwareVpdManufacturingIDNumberread-onlymandatoryStorage Module hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.13ColumnstmHardwareVpdProductIdread-onlymandatoryStorage Module hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.14ColumnstmHardwareVpdSubManufacturerIdread-onlymandatoryStorage Module hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.15ColumnstmHardwareVpdCleiread-onlymandatoryStorage Module hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.18.1.1.16ColumnstmHardwareVpdHardwareRevisionStringread-onlymandatoryStorage Module hardware VPD hardware revision in string format. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is…
1.3.6.1.4.1.2.3.51.2.2.21.19NodestmFirmwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.19.1TablestmFirmwareVpdTablenot-accessiblemandatoryTable of the Storage Module firmware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1RowstmFirmwareVpdEntrynot-accessiblemandatoryStorage Module firmware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.1ColumnstmFirmwareVpdIndexread-onlymandatoryStorage Module firmware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.2ColumnstmFirmwareVpdTyperead-onlymandatoryStorage Module firmware VPD type. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.3ColumnstmFirmwareVpdBuildIdread-onlymandatoryStorage Module firmware VPD build ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.4ColumnstmFirmwareVpdReleaseDateread-onlymandatoryStorage Module firmware VPD release date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.19.1.1.5ColumnstmFirmwareVpdRevisionread-onlymandatoryStorage Module firmware VPD revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21NodebbuHardwareVpd
1.3.6.1.4.1.2.3.51.2.2.21.21.1TablebbuHardwareVpdTablenot-accessiblemandatoryTable of the Battery Backup Unit hardware components. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS o…
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1RowbbuHardwareVpdEntrynot-accessiblemandatoryBattery Backup Unit hardware VPD entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.1ColumnbbuHardwareVpdIndexread-onlymandatoryBattery Backup Unit hardware VPD index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.2ColumnbbuHardwareVpdBayNumberread-onlymandatoryBattery Backup Unit hardware VPD Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.3ColumnbbuHardwareVpdManufacturingIdread-onlymandatoryBattery Backup Unit hardware VPD manufacturing ID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.4ColumnbbuHardwareVpdFruNumberread-onlymandatoryBattery Backup Unit hardware VPD FRU number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.5ColumnbbuHardwareVpdHardwareRevisionread-onlymandatoryBattery Backup Unit hardware VPD hardware revision. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS onl…
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.8ColumnbbuHardwareVpdUuidread-onlymandatoryBattery Backup Unit hardware VPD UUID. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.9ColumnbbuHardwareVpdManufDateread-onlymandatoryBattery Backup Unit hardware VPD manufacture Date. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.10ColumnbbuHardwareVpdPartNumberread-onlymandatoryBattery Backup Unit hardware VPD Part Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.11ColumnbbuHardwareVpdFruSerialread-onlymandatoryBattery Backup Unit hardware VPD FRU Serial Number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS onl…
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.12ColumnbbuHardwareVpdManufacturingIDNumberread-onlymandatoryBattery Backup Unit hardware VPD manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.13ColumnbbuHardwareVpdProductIdread-onlymandatoryBattery Backup Unit hardware VPD product ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.14ColumnbbuHardwareVpdSubManufacturerIdread-onlymandatoryBattery Backup Unit hardware VPD subsystem manufacturer ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.21.1.1.15ColumnbbuHardwareVpdCleiread-onlymandatoryBattery Backup Unit hardware VPD Common Language Equipment Identifier (CLEI). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22TableinventoryManagementActivityVpdTablenot-accessiblemandatoryTable of system component hardware VPD activity log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1RowinventoryManagementActivityVpdEntrynot-accessiblemandatorySystem component hardware VPD activity log entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.1ColumncomponentLevelActivityVpdIndexread-onlymandatorySystem component level VPD activity log index. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.2ColumncomponentLevelActivityVpdFruNumberread-onlymandatorySystem component level VPD activity log FRU number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.3ColumncomponentLevelActivityVpdSerialNumberread-onlymandatorySystem component level VPD activity log serial number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.4ColumncomponentLevelActivityVpdManufacturingIdread-onlymandatorySystem component level VPD activity log manufacturing ID. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.5ColumncomponentLevelActivityVpdBayNumberread-onlymandatorySystem component level VPD activity log Bay number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.9ColumncomponentLevelActivityVpdActionread-onlymandatorySystem component level VPD activity log action (added/removed). For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.10ColumncomponentLevelActivityVpdTimestampread-onlymandatorySystem component level VPD activity log timestamp. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.22.1.12ColumncomponentLevelActivityVpdModuleNameread-onlymandatoryThe module name which this row is associated with. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.2.21.23NodereloadVpdData
1.3.6.1.4.1.2.3.51.2.2.21.23.1ScalarreloadAllVpdDataread-writemandatoryReload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID). NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.2ScalarreloadFwVpdDataread-writemandatoryReload firmware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.3ScalarreloadHwVpdDataread-writemandatoryReload hardware VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.4ScalarreloadMACAddressread-writemandatoryReload blade MAC addresses. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.21.23.5ScalarreloadWwnGuidVpdDataread-writemandatoryReload blade and I/O module WWN/GUID and other VPD data. NOTE: The value returned for the GET command is meaningless.
1.3.6.1.4.1.2.3.51.2.2.22NodeairFilter
1.3.6.1.4.1.2.3.51.2.2.22.1NodepassiveAirFilter
1.3.6.1.4.1.2.3.51.2.2.22.1.1ScalarpassiveAirFilterStatusread-writemandatoryDisable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date. The reset command is only applicable in Blad…
1.3.6.1.4.1.2.3.51.2.2.22.1.2ScalarpassiveAirFilterMonthFreqread-writemandatoryThe chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust. NOTE: This MIB object is for BladeCent…
1.3.6.1.4.1.2.3.51.2.2.22.1.3ScalarpassiveAirFilterReplaceDateread-onlymandatoryThe scheduled replacement date of the air filter. NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only.
1.3.6.1.4.1.2.3.51.2.2.23NodecomponentInformation
1.3.6.1.4.1.2.3.51.2.2.23.1NodecomponentInventory
1.3.6.1.4.1.2.3.51.2.2.23.1.1TablecomponentInventoryTablenot-accessiblemandatoryTable of component inventory information. Not all components will provide every object defined in the ComponentInventoryEntry.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1RowcomponentInventoryEntrynot-accessiblemandatoryComponent inventory information.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.1ColumncomponentInventoryTopologyPathread-onlymandatoryThe unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.2ColumncomponentInventoryInstanceread-onlymandatoryThe slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some compo…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.3ColumncomponentInventoryDescriptionread-onlymandatoryA short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configur…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.4ColumncomponentInventoryMachineTypeModelread-onlymandatoryThe machine type and model number of this component. Typically, the format is XXXXYYY, where XXXX reprsents the machine type and YYY represents the model numbe…
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.5ColumncomponentInventoryMachineSerialread-onlymandatoryThe machine serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.6ColumncomponentInventoryAssetIDread-onlymandatoryThe asset identifier of this component, typically set by some other authority than the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.7ColumncomponentInventoryPartNumberread-onlymandatoryThe part number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.8ColumncomponentInventoryFRUNumberread-onlymandatoryThe Field Replaceable Unit (FRU) number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.9ColumncomponentInventoryFRUSerialNumberread-onlymandatoryThe Field Replaceable Unit (FRU) serial number of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.10ColumncomponentInventoryManufactureIDread-onlymandatoryThe text description of the manufacturer of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.11ColumncomponentInventoryHardwareRevisionread-onlymandatoryThe hardware revision number of the this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.12ColumncomponentInventoryManufactureDateread-onlymandatoryThe date when the manufacturer created this component. The format is XXYY, where XX is the week number of the year 20YY.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.13ColumncomponentInventoryUUIDread-onlymandatoryThe Universally Unique IDentifier (UUID) of this component, represented as a 16 byte hex number.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.14ColumncomponentInventoryProductIDread-onlymandatoryThe product identifier of the component assigned by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.15ColumncomponentInventorySubManufactureIDread-onlymandatoryThe text sub-description of the manufacturer of this component, often used to identify a supplier for a component which has multiple suppliers.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.16ColumncomponentInventoryCLEIread-onlymandatoryThe Common Language Equipment Identifier (CLEI) of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.17ColumncomponentInventoryAssetTagread-onlymandatoryThe asset tag of this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.18ColumncomponentInventorySpeedread-onlymandatoryA speed designation for the component, for example, processor speed.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.19ColumncomponentInventoryIdentifierread-onlymandatoryA unique identifier assigned by the manufacturer to the component, for example, a processor ID.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.20ColumncomponentInventorySizeread-onlymandatoryA size designation for the component, for example, a memory DIMM size or hard drive capacity.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.21ColumncomponentInventoryMemoryTyperead-onlymandatoryThe architecture specification of a memory device.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.22ColumncomponentInventoryProductNameread-onlymandatoryThe product name assigned by the manufacturer for this component. For more detail, also refer to the componentInventoryDescription object.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.23ColumncomponentInventoryProductVersionread-onlymandatoryThe product version assigned by the manufacturer for this component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.24ColumncomponentInventoryProcessorTyperead-onlymandatoryThe type designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.25ColumncomponentInventoryProcessorFamilyread-onlymandatoryThe family designation for processor components.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.26ColumncomponentInventoryProcessorCoresread-onlymandatoryThe number of cores present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.27ColumncomponentInventoryProcessorThreadsread-onlymandatoryThe number of threads present on a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.28ColumncomponentInventoryProcessorL1DCacheread-onlymandatoryThe level 1 data cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.29ColumncomponentInventoryProcessorL1ICacheread-onlymandatoryThe level 1 instruction cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.30ColumncomponentInventoryProcessorL2Cacheread-onlymandatoryThe level 2 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.31ColumncomponentInventoryProcessorL3Cacheread-onlymandatoryThe level 3 cache size of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.32ColumncomponentInventoryProcessorVoltageread-onlymandatoryThe voltage rating for a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.33ColumncomponentInventoryProcessorExtClockread-onlymandatoryThe external clock speed of a processor component.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.34ColumncomponentInventoryProcessorDataWidthread-onlymandatoryThe maximum data bus width capability of a processor component, expressed typically in bits.
1.3.6.1.4.1.2.3.51.2.2.23.1.1.1.35ColumncomponentInventoryManufactureIDNumread-onlymandatoryThe identification number assigned for the component by the manufacturer.
1.3.6.1.4.1.2.3.51.2.2.23.2NodecomponentFirmware
1.3.6.1.4.1.2.3.51.2.2.23.2.1TablecomponentFirmwareTablenot-accessiblemandatoryTable of component firmware information. Not all components will provide every object defined in the ComponentFirmwareEntry.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1RowcomponentFirmwareEntrynot-accessiblemandatoryComponent firmware information.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.1ColumncomponentFirmwareTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.2ColumncomponentFirmwareIndexread-onlymandatoryEach component may have one or more types of firmware associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.3ColumncomponentFirmwareComponentInstanceread-onlymandatoryThe slot number or instance of a particular component. Typically, if the component plugs into the chassis, this represents the slot number. However, some compo…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.4ColumncomponentFirmwareComponentDescriptionread-onlymandatoryA short text string describing the particular component. For the AMM and blades, this name will be the configured name or its serial number if no user configur…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.5ColumncomponentFirmwareTyperead-onlymandatoryA text description of the type of firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.6ColumncomponentFirmwareBuildIDread-onlymandatoryA text description of the build identifier for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.7ColumncomponentFirmwareReleaseDateread-onlymandatoryA text description of the release date for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.8ColumncomponentFirmwareFilenameread-onlymandatoryA text description of the filename of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.9ColumncomponentFirmwareRevisionread-onlymandatoryA text description of the revision level of this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.10ColumncomponentFirmwareRevisionMajorread-onlymandatoryA numeric identifier of the revision major number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.11ColumncomponentFirmwareRevisionMinorread-onlymandatoryA numeric identifier of the revision minor number for this firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.12ColumncomponentFirmwareLevelStatusread-onlymandatoryThe level status of the firmware build ID. It has three possible values as Different (mismatch firmware build ID), Match (the same firmware build ID), Unique (…
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.13ColumncomponentFirmwarePendingBuildIDread-onlymandatoryA text description of the build identifier for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.14ColumncomponentFirmwarePendingReleaseDateread-onlymandatoryA text description of the release date for this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.15ColumncomponentFirmwarePendingRevisionread-onlymandatoryA text description of the revision level of this pending firmware load.
1.3.6.1.4.1.2.3.51.2.2.23.2.1.1.20ColumncomponentFirmwareTypeIDread-onlymandatoryIndicates the type of firmware load with a numeric identifier.
1.3.6.1.4.1.2.3.51.2.2.23.3ScalarcomponentInventoryReadyread-onlymandatoryWhen a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - ser…
1.3.6.1.4.1.2.3.51.2.2.23.10TablecomponentDriveTablenot-accessiblemandatoryTable of information indicating presence of a disk drive on a component. The management module does not receive any inventory VPD from the component, so only t…
1.3.6.1.4.1.2.3.51.2.2.23.10.1RowcomponentDriveEntrynot-accessiblemandatoryComponent drive information.
1.3.6.1.4.1.2.3.51.2.2.23.10.1.1ColumncomponentDriveTopologyPathread-onlymandatoryThe unique identifier for a row in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in the tree…
1.3.6.1.4.1.2.3.51.2.2.23.10.1.2ColumncomponentDriveDescriptionread-onlymandatoryA short text string describing the particular drive on the component.
1.3.6.1.4.1.2.3.51.2.3NodeerrorLogs
1.3.6.1.4.1.2.3.51.2.3.4NodeeventLog
1.3.6.1.4.1.2.3.51.2.3.4.2TablereadEventLogTablenot-accessiblemandatoryTable of event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.2.1RowreadEventLogEntrynot-accessiblemandatoryEvent log table entry
1.3.6.1.4.1.2.3.51.2.3.4.2.1.1ColumnreadEventLogIndexread-onlymandatoryThe event log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.2.1.2ColumnreadEventLogStringread-onlymandatoryA string of data detailing an event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.3ScalarclearEventLogread-writemandatoryClear the event log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.4ScalarmonitorLogStateEventsread-writemandatoryIf disabled, it means the info LED will not turn on when the log gets full and no alerts will be sent out. If enabled, the LED will turn on when the log gets f…
1.3.6.1.4.1.2.3.51.2.3.4.6TablereadEnhancedEventLogTablenot-accessiblemandatoryTable of enhanced event log entry information.
1.3.6.1.4.1.2.3.51.2.3.4.6.1RowreadEnhancedEventLogEntrynot-accessiblemandatoryEnhaced Event log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.1ColumnreadEnhancedEventLogNumberread-onlymandatoryThe event log number for the enhanced event log. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.6.1.2ColumnreadEnhancedEventLogAttributeread-onlymandatoryA string of data detailing an event log's attribute, such as the Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or …
1.3.6.1.4.1.2.3.51.2.3.4.6.1.3ColumnreadEnhancedEventLogMessageread-onlymandatoryA string of data detailing an event log message. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.10TablereadAuditLogTablenot-accessiblemandatoryTable of audit log entry information. Audit log includes the logs whose source is 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.10.1RowreadAuditLogEntrynot-accessiblemandatoryAudit log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.1ColumnreadAuditLogNumberread-onlymandatoryThe audit log number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.2ColumnreadAuditLogAttributeread-onlymandatoryA string of data detailing an audit eventlog's attribute. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.10.1.3ColumnreadAuditLogMessageread-onlymandatoryA string of data detailing an audit event log message. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.11ScalarclearAuditLogread-writemandatoryClear the audit log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.3.4.12TablereadSystemLogTablenot-accessiblemandatoryTable of system log entry information. System log includes the logs whose source is other than 'Audit'
1.3.6.1.4.1.2.3.51.2.3.4.12.1RowreadSystemLogEntrynot-accessiblemandatorySystem log table entry, new entries could be added for new items.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.1ColumnreadSystemLogNumberread-onlymandatoryThe system log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.2ColumnreadSystemLogAttributeread-onlymandatoryA string of data detailing an system event log's attribute. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.12.1.3ColumnreadSystemLogMessageread-onlymandatoryA string of data detailing an system event log message. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.3.4.13ScalarclearSystemLogread-writemandatoryClear the system log. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4NodeconfigureSP
1.3.6.1.4.1.2.3.51.2.4.1NoderemoteAccessConfig
1.3.6.1.4.1.2.3.51.2.4.1.1NodegeneralRemoteCfg
1.3.6.1.4.1.2.3.51.2.4.1.1.3ScalarremoteAlertRetryDelayread-writemandatoryNumber in seconds to delay between retries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.2.3.51.2.4.1.1.4ScalarremoteAlertRetryCountread-writemandatoryNumber of additional times a remote alert will be retried if not successfully sent. A value of zero indicates no retries will be attempted.
1.3.6.1.4.1.2.3.51.2.4.1.1.5ScalarremoteAlertEntryDelayread-onlydeprecatedNumber in seconds to delay between entries if sending a remote alert is unsuccessful. NOTE: This object is no longer supported. However, for compatibilities sa…
1.3.6.1.4.1.2.3.51.2.4.1.1.6ScalarremoteAccessTamperDelayread-writedeprecatedThis value is no longer supported and has been replaced by 'lockoutPeriod'.
1.3.6.1.4.1.2.3.51.2.4.1.1.7ScalaruserAuthenticationMethodread-writemandatoryUse this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified …
1.3.6.1.4.1.2.3.51.2.4.1.1.9ScalarmaxSessionsPerLDAPUserread-writemandatoryThe maximum number of simultaneous active sessions allowed for each LDAP user. If the value is 0, this option is disabled. The minimum value is 1 and the maxim…
1.3.6.1.4.1.2.3.51.2.4.1.1.10ScalarauthenticationLoggingTimeoutread-writemandatoryUse this option to set how long, in seconds, AMM will not log the authentication events for the same user. The default setting is 5 minutes. 0 indicates log al…
1.3.6.1.4.1.2.3.51.2.4.1.1.11ScalartrackingIPread-writemandatoryThis option indicates tracking different IP addresses for the same user is enabled or not. If it is enabled then an access every second from alternating IP add…
1.3.6.1.4.1.2.3.51.2.4.1.1.20NodeaccountSecurityManagement
1.3.6.1.4.1.2.3.51.2.4.1.1.20.1ScalaraccountSecurityLevelread-writemandatoryThe level of security needed for local user login passwords. The legacy level: - no password required - no password expiration - no password re-use restriction…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2NodecustomSecuritySettings
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.1ScalarloginPasswordRequiredread-writemandatoryIf enabled, all users require a login password to access the AMM. If disabled, empty password is allowed and complex password rules will be disabled automatica…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.2ScalarpasswordExpirationPeriodread-writemandatoryThe number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disa…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.3ScalardefaultAdminPasswordExpiredread-writemandatoryIf enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.4ScalarminimumPasswordReuseCycleread-writemandatoryThe number of unique passwords a user must choose before reusing a password. The default value is none.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.5ScalarcomplexPasswordRulesread-writemandatoryIf enabled, the minimum complexity rules will be enforced for all local login passwords and 'User login password required' rule will be enabled. The rules are …
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.6ScalarminimumDiffCharsPasswordread-writemandatoryThe required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored unt…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.7ScalarchangePasswordFirstAccessread-writemandatoryIf enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an a…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.8ScalarinactivityAlertPeriodread-writemandatoryThe period of time in days before generating an alert for a dormant account. This value applies to all login accounts, including the administrator account. The…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.9ScalarinactivityAlertDisablePeriodread-writemandatoryThe period of time in days before generating an alert and disabling a dormant account. This value applies to all login accounts, excluding the administrator ac…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.10ScalarlockoutPeriodread-writemandatoryThe period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximu…
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.11ScalarmaxLoginFailuresread-writemandatoryThe maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5.
1.3.6.1.4.1.2.3.51.2.4.1.1.20.2.12ScalarpasswordChangeIntervalread-writemandatoryA minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 1440 (or 60 days). A value of 0 d…
1.3.6.1.4.1.2.3.51.2.4.1.2NodeserialPortCfg
1.3.6.1.4.1.2.3.51.2.4.1.2.1ScalarportBaudread-writemandatoryBaud rate for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.2ScalarportParityread-writemandatoryParity setting for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.2.3ScalarportStopBitsread-writemandatoryNumber of stop bits for the serial port.
1.3.6.1.4.1.2.3.51.2.4.1.3NoderemoteAlertIds
1.3.6.1.4.1.2.3.51.2.4.1.3.1TableremoteAlertIdsTablenot-accessiblemandatoryTable of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients. NOTE: All selected alert event…
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1RowremoteAlertIdsEntrynot-accessiblemandatoryRemote alert entries.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.1ColumnremoteAlertIdEntryIndexread-onlymandatoryIndex for remote alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.2ColumnremoteAlertIdEntryStatusread-writemandatoryRemote alert entry status, invalid means entry not defined yet, disabledAndValid means entry defined but not enabled to send an alert, enabledAndValid means en…
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.3ColumnremoteAlertIdEntryIpOrHostAddressread-writemandatoryA null terminated string that either contains an IP address of the form '1.2.3.4' or a host name (if DNS is enabled) for the alert entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.4ColumnremoteAlertIdEntryTextDescriptionread-writemandatoryA null terminated string that contains a text description of this entry.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.5ColumnremoteAlertIdEntryNotificationTyperead-writemandatoryRemote alert entry notification method. Types include unknown when the type can't be determined (read-only), ibmDirectorOverLAN for a LAN alert sent over ether…
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.9ColumnremoteAlertIdEmailAddrread-writemandatoryA null terminated string that contains an E-Mail Address. For example, 'jeb@us.ibm.com'. Used only for an E-mail over LAN or E-Mail over PPP notification type.
1.3.6.1.4.1.2.3.51.2.4.1.3.1.1.13ColumnremoteAlertIdEntrySelectiveAlertread-writemandatoryRemote alert entry selective alert setting. A value of critOnlyAlerts will only send critical alerts to this remote alert recipient, a value of allAlerts will …
1.3.6.1.4.1.2.3.51.2.4.1.3.30ScalargenerateTestAlertread-writemandatoryGenerate a Test Alert. This will send a test alert to all configured and enabled remote alert recipients. The text portion of the alert will contain 'Applicati…
1.3.6.1.4.1.2.3.51.2.4.1.4NoderemoteAccessIds
1.3.6.1.4.1.2.3.51.2.4.1.4.1TableremoteAccessIdsTablenot-accessiblemandatoryTable of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. NOTE: By default, the management…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1RowremoteAccessIdsEntrynot-accessiblemandatoryRemote access entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.1ColumnremoteAccessIdEntryIndexread-onlymandatoryIndex for Remote access entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.2ColumnremoteAccessIdEntryUserIdread-writemandatoryRemote access entry null terminated string that contains the user-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.3ColumnremoteAccessIdEntryPasswordread-writemandatoryRemote access password. The password must contain at least one alphabetic and one non-alphabetic character and be at least 5 characters long, or you can leave …
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.7ColumnremoteAccessIdEntryEncodedLoginPwread-writedeprecatedUsed only for configuration save/restore. A null terminated string containing an encoded concatenation of the login ID and password separated by an ':'. This o…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.10ColumnremoteAccessIdEntryRoleread-onlymandatoryIndicates if user has supervisor, operator, or custom access.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.11ColumnremoteAccessIdEntryLoggedInread-onlymandatoryIndicates if user is currently logged in or not.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.12ColumnremoteAccessIdEntryLastLoginread-onlymandatoryTimestamp for the last successful login by the user.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.13ColumnremoteAccessIdEntryPwdCompliantread-onlymandatoryIndicates if user complies with all of the password rules currently in effect.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.14ColumnremoteAccessIdEntryPwdExpread-onlymandatoryThe number of days until the user's current password expires.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.15ColumnremoteAccessIdEntryDormantread-onlymandatoryIndicates if the user account has been inactive for a specified amount of time based on inactivityAlertDisablePeriod in the customSecuritySettings section.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.16ColumnremoteAccessIdEntryStateread-onlymandatoryIndicates the state of the user: Active - normal state Disabled - user cannot use account until enabled by a supervisor or chassis user account manager. An acc…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.17ColumnremoteAccessIdEntryActionread-writemandatoryActions that only a supervisor or chassis user account manager can perform for each user id: Enable - enables an account in the Disabled state Disable - disabl…
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.18ColumnremoteAccessIdEntrySessionCountread-onlymandatoryThe number of sessions the user is currently logged in to.
1.3.6.1.4.1.2.3.51.2.4.1.4.1.1.19ColumnremoteAccessIdEntryMaxSessionsread-writemandatoryThe maximum number of simultaneous active sessions allowed for the user. If the value is 0, this option is disabled. The minimum value is 1 and the maximum val…
1.3.6.1.4.1.2.3.51.2.4.1.4.2TableremoteAccessUserAuthorityLevelTablenot-accessiblemandatoryTable of user authority level profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1RowremoteAccessUserAuthorityLevelEntrynot-accessiblemandatoryUser authority level entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.1ColumnualIndexread-onlymandatoryIndex for User Authority Level entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.2ColumnualIdread-onlymandatoryUser ID
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.3ColumnualSupervisorread-writemandatoryUser has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.4ColumnualReadOnlyread-writemandatoryUser has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmw…
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.5ColumnualAccountManagementread-writemandatoryUser can add/modify/delete users and change the global login settings in the Login Profiles panel.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.6ColumnualConsoleAccessread-writemandatoryUser can access the remote console.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.7ColumnualConsoleAndVirtualMediaAccessread-writemandatoryUser can access both the remote console and the virtual media feature.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.8ColumnualServerPowerAccessread-writemandatoryUser can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.9ColumnualAllowClearLogread-writemandatoryUser can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.10ColumnualAdapterBasicConfigread-writemandatoryUser can modify configuration parameters in the System Settings and Alerts panels.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.11ColumnualAdapterNetworkAndSecurityConfigread-writemandatoryUser can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
1.3.6.1.4.1.2.3.51.2.4.1.4.2.1.12ColumnualAdapterAdvancedConfigread-writemandatoryUser has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the RSA, meaning that the user can also p…
1.3.6.1.4.1.2.3.51.2.4.1.4.3TableremoteAccessRBSroleTablenot-accessiblemandatoryTable of RBS User Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1RowremoteAccessRBSroleEntrynot-accessiblemandatoryUser Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.1ColumnroleIndexread-onlymandatoryIndex for RBS User Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.2ColumnroleIdread-onlymandatoryUser ID
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.3ColumnrbsSupervisorread-writemandatoryUser has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.4ColumnrbsOperatorread-writemandatoryUser has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware, …
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.5ColumnrbsChassisOperatorread-writemandatoryUser has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to …
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.6ColumnrbsChassisAccountManagementread-writemandatoryUser can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration auth…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.7ColumnrbsChassisLogManagementread-writemandatoryUser has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.8ColumnrbsChassisConfigurationread-writemandatoryUser can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the user …
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.9ColumnrbsChassisAdministrationread-writemandatoryUser has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the user also has chassis configuration permissions. Ability to…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.10ColumnrbsBladeOperatorread-writemandatoryUser has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.11ColumnrbsBladeRemotePresenceread-writemandatoryUser has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue the…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.12ColumnrbsBladeConfigurationread-writemandatoryUser can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.13ColumnrbsBladeAdministrationread-writemandatoryUser can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.14ColumnrbsSwitchModuleOperatorread-writemandatoryUser has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.15ColumnrbsSwitchModuleConfigurationread-writemandatoryUser can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a user…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.16ColumnrbsSwitchModuleAdministrationread-writemandatoryUser can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a us…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.17ColumnrbsBladeRemotePresenseVideoread-writedeprecatedUser can browser Remote Control web panel and remote blade video. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.18ColumnrbsBladeRemotePresenseKVMread-writedeprecatedUser has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. NOTE: This mib object is…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.19ColumnrbsBladeRemotePresenseRdriveRread-writedeprecatedUser can mount remote blade driver, and have read access only. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.20ColumnrbsBladeRemotePresenseRdriveRWread-writedeprecatedUser can mount remote blade driver and have read/write access. NOTE: This mib object is deprecated. This level of granularity is available via the LDAP snap-in…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.21ColumnrbsChassisRemotePresenseRdocread-writedeprecatedUser has ability to upload/delete own image to RDOC and also can start remote control web panel. NOTE: This mib object is deprecated. This level of granularity…
1.3.6.1.4.1.2.3.51.2.4.1.4.3.1.22ColumnrbsRemotePresenceSupervisorread-writedeprecatedUser has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote driver read/write, upload/dele…
1.3.6.1.4.1.2.3.51.2.4.1.4.4TableremoteAccessRBSscopeTablenot-accessiblemandatoryTable of RBS User Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1RowremoteAccessRBSscopeEntrynot-accessiblemandatoryUser Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.1ColumnscopeIndexread-onlymandatoryIndex for RBS User Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.2ColumnscopeIdread-onlymandatoryUser ID
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.3ColumnrbsChassisread-writemandatoryUser has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.4ColumnrbsBlade1read-writemandatoryUser has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.5ColumnrbsBlade2read-writemandatoryUser has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.6ColumnrbsBlade3read-writemandatoryUser has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.7ColumnrbsBlade4read-writemandatoryUser has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.8ColumnrbsBlade5read-writemandatoryUser has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.9ColumnrbsBlade6read-writemandatoryUser has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.10ColumnrbsBlade7read-writemandatoryUser has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.11ColumnrbsBlade8read-writemandatoryUser has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.12ColumnrbsBlade9read-writemandatoryUser has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.13ColumnrbsBlade10read-writemandatoryUser has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.14ColumnrbsBlade11read-writemandatoryUser has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.15ColumnrbsBlade12read-writemandatoryUser has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.16ColumnrbsBlade13read-writemandatoryUser has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.17ColumnrbsBlade14read-writemandatoryUser has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.18ColumnrbsSwitch1read-writemandatoryUser has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.19ColumnrbsSwitch2read-writemandatoryUser has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.20ColumnrbsSwitch3read-writemandatoryUser has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.21ColumnrbsSwitch4read-writemandatoryUser has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.22ColumnrbsSwitch5read-writemandatoryUser has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.23ColumnrbsSwitch6read-writemandatoryUser has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.24ColumnrbsSwitch7read-writemandatoryUser has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.25ColumnrbsSwitch8read-writemandatoryUser has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.26ColumnrbsSwitch9read-writemandatoryUser has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.4.4.1.27ColumnrbsSwitch10read-writemandatoryUser has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.1.5NodeuserInterfaces
1.3.6.1.4.1.2.3.51.2.4.1.5.1Scalarcliread-writemandatoryEnable/Disable CLI access to the MM (telnet and SSH). The value enabled(3) means both telnet and ssh are enabled.
1.3.6.1.4.1.2.3.51.2.4.1.5.2Scalarsnmpread-writemandatoryEnable/Disable SNMP v1 and v3 access to the MM.
1.3.6.1.4.1.2.3.51.2.4.1.5.3Scalartcmread-writemandatoryEnable/Disable TCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for both…
1.3.6.1.4.1.2.3.51.2.4.1.5.4Scalarwebread-writemandatoryEnable/Disable Web access (HTTP/HTTPS) to the MM. NOTE: Disabling web access to the MM will cause all currently active web sessions to disconnect, and you will…
1.3.6.1.4.1.2.3.51.2.4.1.5.5Scalarstcmread-writemandatoryEnable/Disable STCM access to the MM. A value of 0 means disabled, any value from 1 to 20 means enabled. NOTE: AMM will provide a max of 20 connections for bot…
1.3.6.1.4.1.2.3.51.2.4.1.6NodemmSshClientAuth
1.3.6.1.4.1.2.3.51.2.4.1.6.1TablemmSshClientAuthPubKeyTablenot-accessiblemandatoryA table that contains client authentication public key information.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1RowmmSshClientAuthPubKeyEntrynot-accessiblemandatoryA information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessId…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.1ColumnmmSshClientAuthRemoteAccessIdIndexnot-accessiblemandatoryThe primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.2ColumnmmSshClientAuthPubKeyIndexnot-accessiblemandatoryThe secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 t…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.3ColumnmmSshClientAuthPubKeyTyperead-onlymandatoryThe type of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.4ColumnmmSshClientAuthPubKeySizeread-onlymandatoryThe size of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.5ColumnmmSshClientAuthPubKeyFingerprintread-onlymandatoryThe RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the …
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.6ColumnmmSshClientAuthPubKeyAcceptFromread-writemandatoryThis is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the AMM authenticated by the public key…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.7ColumnmmSshClientAuthPubKeyCommentread-writemandatoryThis is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation o…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.8ColumnmmSshClientAuthPubKeyActionread-writemandatoryimport(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the AMM. The import operation is only accepted if th…
1.3.6.1.4.1.2.3.51.2.4.1.6.1.1.9ColumnmmSshClientAuthPubKeyEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set…
1.3.6.1.4.1.2.3.51.2.4.1.6.2ScalarmmSshClientAuthPubKeyUnusedread-onlymandatoryThe number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key…
1.3.6.1.4.1.2.3.51.2.4.1.6.3ScalarmmSshClientAuthPubKeyTftpServerread-writemandatoryIP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in…
1.3.6.1.4.1.2.3.51.2.4.1.6.4ScalarmmSshClientAuthPubKeyFileNameread-writemandatoryFile name on the TFTP server of an SSH client authentication public key.
1.3.6.1.4.1.2.3.51.2.4.1.6.5ScalarmmSshClientAuthPubKeyFileFormatread-writemandatoryFile format of SSH client authentication public key files imported from or exported to the TFTP file server.
1.3.6.1.4.1.2.3.51.2.4.1.7NodegroupProfiles
1.3.6.1.4.1.2.3.51.2.4.1.7.1TablegroupIdsTablenot-accessiblemandatoryTable of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1RowgroupIdsEntrynot-accessiblemandatoryGroup ID entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.1ColumngroupIndexread-onlymandatoryIndex for Group IDs entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.2ColumngroupIdread-writemandatoryGroup ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.3ColumngroupRoleread-onlymandatoryGroup Role. It indicates if the group has supervisor, operator, or custom access.
1.3.6.1.4.1.2.3.51.2.4.1.7.1.1.9ColumngroupEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to add a new group are: 1. Create a new entry in this table groupEntryStatus…
1.3.6.1.4.1.2.3.51.2.4.1.7.2TablegroupRBSroleTablenot-accessiblemandatoryTable of Group Role profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1RowgroupRBSroleEntrynot-accessiblemandatoryGroup Role entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.1ColumngroupRBSroleIndexread-onlymandatoryIndex for Group Role entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.2ColumngroupRBSroleIdread-onlymandatoryGroup ID
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.3ColumngroupRBSSupervisorread-writemandatoryGroup has no restrictions.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.4ColumngroupRBSOperatorread-writemandatoryGroup has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart MM, restore defaults, upgrade the firmware,…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.5ColumngroupRBSChassisOperatorread-writemandatoryGroup has ability to browse status and properties of chassis components (MM, blowers (chassis cooling devices), midplane, power modules, media tray. Ability to…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.6ColumngroupRBSChassisAccountManagementread-writemandatoryGroup can add/modify/delete user login profiles. Ability to backup MM configuration to a file. Changing global login settings require chassis configuration aut…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.7ColumngroupRBSChassisLogManagementread-writemandatoryGroup has ability to clear the MM event log, change log policy settings, and backup MM configuration to a file.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.8ColumngroupRBSChassisConfigurationread-writemandatoryGroup can modify and save any chassis configuration parameter (except user profiles and event log settings). Ability to restore MM factory defaults if the grou…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.9ColumngroupRBSChassisAdministrationread-writemandatoryGroup has ability to do MM firmware updates, modify chassis LEDs, restore MM factory defaults if the group also has chassis configuration permissions. Ability …
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.10ColumngroupRBSBladeOperatorread-writemandatoryGroup has ability to browse status and properties of blades.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.11ColumngroupRBSBladeRemotePresenceread-writemandatoryGroup has ability to access the Remote Control web panel and the functions provided on the panel: remote console (KVM) and remote disk. The ability to issue th…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.12ColumngroupRBSBladeConfigurationread-writemandatoryGroup can modify and save any blade configuration parameter.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.13ColumngroupRBSBladeAdministrationread-writemandatoryGroup can power on/off and restart blades, activate standby blades, do firmware updates, and modify blade LEDs.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.14ColumngroupRBSSwitchModuleOperatorread-writemandatoryGroup has ability to browse status and properties of I/O Modules, and to ping I/O Modules.
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.15ColumngroupRBSSwitchModuleConfigurationread-writemandatoryGroup can modify the I/O Module IP address, configure I/O Module Advanced Management parameters, and restore factory defaults on an I/O Module. Note that a gro…
1.3.6.1.4.1.2.3.51.2.4.1.7.2.1.16ColumngroupRBSSwitchModuleAdministrationread-writemandatoryGroup can power on/off and restart the I/O Modules, update I/O Module firmware, enable/disable the Fast POST and External Ports of an I/O Module. Note that a g…
1.3.6.1.4.1.2.3.51.2.4.1.7.3TablegroupRBSscopeTablenot-accessiblemandatoryTable of Group Scope profiles.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1RowgroupRBSscopeEntrynot-accessiblemandatoryGroup Scope entries.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.1ColumngroupRBSscopeIndexread-onlymandatoryIndex for Group Scope Entry.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.2ColumngroupRBSscopeIdread-onlymandatoryGroup ID
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.3ColumngroupRBSChassisread-writemandatoryGroup has access to the MM and chassis functions.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.4ColumngroupRBSBlade1read-writemandatoryGroup has access to the blade in slot 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.5ColumngroupRBSBlade2read-writemandatoryGroup has access to the blade in slot 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.6ColumngroupRBSBlade3read-writemandatoryGroup has access to the blade in slot 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.7ColumngroupRBSBlade4read-writemandatoryGroup has access to the blade in slot 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.8ColumngroupRBSBlade5read-writemandatoryGroup has access to the blade in slot 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.9ColumngroupRBSBlade6read-writemandatoryGroup has access to the blade in slot 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.10ColumngroupRBSBlade7read-writemandatoryGroup has access to the blade in slot 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.11ColumngroupRBSBlade8read-writemandatoryGroup has access to the blade in slot 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.12ColumngroupRBSBlade9read-writemandatoryGroup has access to the blade in slot 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.13ColumngroupRBSBlade10read-writemandatoryGroup has access to the blade in slot 10.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.14ColumngroupRBSBlade11read-writemandatoryGroup has access to the blade in slot 11.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.15ColumngroupRBSBlade12read-writemandatoryGroup has access to the blade in slot 12.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.16ColumngroupRBSBlade13read-writemandatoryGroup has access to the blade in slot 13.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.17ColumngroupRBSBlade14read-writemandatoryGroup has access to the blade in slot 14.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.18ColumngroupRBSSwitch1read-writemandatoryGroup has access to I/O module 1.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.19ColumngroupRBSSwitch2read-writemandatoryGroup has access to I/O module 2.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.20ColumngroupRBSSwitch3read-writemandatoryGroup has access to I/O module 3.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.21ColumngroupRBSSwitch4read-writemandatoryGroup has access to I/O module 4.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.22ColumngroupRBSSwitch5read-writemandatoryGroup has access to I/O module 5.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.23ColumngroupRBSSwitch6read-writemandatoryGroup has access to I/O module 6.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.24ColumngroupRBSSwitch7read-writemandatoryGroup has access to I/O module 7.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.25ColumngroupRBSSwitch8read-writemandatoryGroup has access to I/O module 8.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.26ColumngroupRBSSwitch9read-writemandatoryGroup has access to I/O module 9.
1.3.6.1.4.1.2.3.51.2.4.1.7.3.1.27ColumngroupRBSSwitch10read-writemandatoryGroup has access to I/O module 10.
1.3.6.1.4.1.2.3.51.2.4.2NoderemoteAlerts
1.3.6.1.4.1.2.3.51.2.4.2.1NoderemoteAlertsCrit
1.3.6.1.4.1.2.3.51.2.4.2.1.1ScalarcritTempread-onlydeprecatedGenerate an alert if any of the monitored temperature sensors in the system exceed their critical threshold. NOTE: If a critical Temperature condition is detec…
1.3.6.1.4.1.2.3.51.2.4.2.1.2ScalarcritVoltread-onlydeprecatedGenerate a alert if any of the monitored power supply sensors in the system fall outside their specified critical operational range. NOTE: If a critical voltag…
1.3.6.1.4.1.2.3.51.2.4.2.1.4ScalarcritMultiBlowerread-onlydeprecatedGenerate an alert if multiple blowers used for cooling the system fail. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode…
1.3.6.1.4.1.2.3.51.2.4.2.1.5ScalarcritPowerread-writemandatoryGenerate an alert if any of the system power supplies fail. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all …
1.3.6.1.4.1.2.3.51.2.4.2.1.6ScalarcritHardDriveread-onlydeprecatedGenerate an alert if any of hard disk drives fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They…
1.3.6.1.4.1.2.3.51.2.4.2.1.7ScalarcritVRMread-onlydeprecatedGenerate an alert if any of VRM (voltage regulator modules) fail. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several…
1.3.6.1.4.1.2.3.51.2.4.2.1.8ScalarcritMultipleSwitchModuleread-onlydeprecatedGenerate an alert if all switch modules fail or are removed. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several rele…
1.3.6.1.4.1.2.3.51.2.4.2.1.9ScalarcritInvalidConfigread-onlydeprecatedGenerate an alert if the hardware configuration is incompatible. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several …
1.3.6.1.4.1.2.3.51.2.4.2.1.10ScalarcritBladeread-writemandatoryGenerate an alert for any critical error condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for a…
1.3.6.1.4.1.2.3.51.2.4.2.1.11ScalarcritIOread-writemandatoryGenerate an alert for any critical error condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used fo…
1.3.6.1.4.1.2.3.51.2.4.2.1.12ScalarcritStorageread-writemandatoryGenerate an alert for any critical error condition on a Storage module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be u…
1.3.6.1.4.1.2.3.51.2.4.2.1.13ScalarcritChassisread-writemandatoryGenerate an alert for any critical error condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for a…
1.3.6.1.4.1.2.3.51.2.4.2.1.14ScalarcritFanread-writemandatoryGenerate an alert for any critical error condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be us…
1.3.6.1.4.1.2.3.51.2.4.2.2NoderemoteAlertsNonCrit
1.3.6.1.4.1.2.3.51.2.4.2.2.2ScalarwarnSingleBlowerread-onlydeprecatedGenerate an alert if one blower used for cooling the system fails. NOTE: Blowers are also referred to as Chassis Cooling Devices. NOTE: The legacy(0) mode aler…
1.3.6.1.4.1.2.3.51.2.4.2.2.3ScalarwarnTempread-onlydeprecatedGenerate an alert if any of the monitored temperature sensors in the system exceed their warning threshold. NOTE: The legacy(0) mode alerts should no longer be…
1.3.6.1.4.1.2.3.51.2.4.2.2.4ScalarwarnVoltageread-onlydeprecatedGenerate an alert if any of the monitored power supply sensors in the system fall outside their specified warning operational range. NOTE: The legacy(0) mode a…
1.3.6.1.4.1.2.3.51.2.4.2.2.6ScalarwarnRedundantModuleread-onlydeprecatedGenerate an alert if any of the switch modules or management modules is failing or removed. NOTE: The legacy(0) mode alerts should no longer be used and have b…
1.3.6.1.4.1.2.3.51.2.4.2.2.7ScalarwarnMediaTrayKVMSwitchread-onlydeprecatedGenerate an alert if the system detects a Media Tray or KVM switching failure. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecate…
1.3.6.1.4.1.2.3.51.2.4.2.2.10ScalarwarnLogFullread-writemandatoryGenerate an alert if the system log reaches 100% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert…
1.3.6.1.4.1.2.3.51.2.4.2.2.15ScalarwarnBladeread-writemandatoryGenerate an alert for any warning condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all aler…
1.3.6.1.4.1.2.3.51.2.4.2.2.16ScalarwarnIOread-writemandatoryGenerate an alert for any warning condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all a…
1.3.6.1.4.1.2.3.51.2.4.2.2.17ScalarwarnStorageread-writemandatoryGenerate an alert for any warning condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode object is…
1.3.6.1.4.1.2.3.51.2.4.2.2.18ScalarwarnPowerread-writemandatoryGenerate an alert for any warning condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all…
1.3.6.1.4.1.2.3.51.2.4.2.2.19ScalarwarnChassisread-writemandatoryGenerate an alert for any warning condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all aler…
1.3.6.1.4.1.2.3.51.2.4.2.2.20ScalarwarnFanread-writemandatoryGenerate an alert for any warning condition on cooling devices. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for …
1.3.6.1.4.1.2.3.51.2.4.2.3NoderemoteAlertsSystem
1.3.6.1.4.1.2.3.51.2.4.2.3.4ScalarsystemPowerOffread-onlydeprecatedGenerate an alert if the system is powered off. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They ar…
1.3.6.1.4.1.2.3.51.2.4.2.3.5ScalarsystemPowerOnread-onlydeprecatedGenerate a alert if the system is powered on. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several releases. They are …
1.3.6.1.4.1.2.3.51.2.4.2.3.8ScalarsystemPFAread-onlydeprecatedGenerate a alert if the system hardware detects a Predictive Failure Analysis(PFA) on PFA enabled hardware. NOTE: The legacy(0) mode alerts should no longer be…
1.3.6.1.4.1.2.3.51.2.4.2.3.10ScalarsystemInventoryread-writemandatoryGenerate an alert if the a processor blade or media tray is added or removed. NOTE: This object is valid when the alertMode object is set enhanced(1) and shoul…
1.3.6.1.4.1.2.3.51.2.4.2.3.11ScalarsystemLog75PctFullread-writemandatoryGenerate an alert if the system log reaches 75% full. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for all alert …
1.3.6.1.4.1.2.3.51.2.4.2.3.12ScalarnetworkChangeNotificationread-writemandatoryGenerate an alert if the SP has restarted and the internal network has initialized successfully, or if an IP address change via a source other than the managem…
1.3.6.1.4.1.2.3.51.2.4.2.3.13ScalarsystemBladeThrottlingread-onlydeprecatedGenerate an alert if any of the server blades are throttling. NOTE: The legacy(0) mode alerts should no longer be used and have been deprecated for several rel…
1.3.6.1.4.1.2.3.51.2.4.2.3.14ScalarsystemPowerManagementread-onlydeprecatedGenerate an alert if the system detects a power oversubscription condition or power supply mismatch in a power domain. NOTE: The legacy(0) mode alerts should n…
1.3.6.1.4.1.2.3.51.2.4.2.3.15ScalarsystemRemoteLoginread-writemandatoryGenerate an alert if the system detects a new user logged in from a remote site. NOTE: This object is valid when the alertMode object is set enhanced(1) and sh…
1.3.6.1.4.1.2.3.51.2.4.2.3.16ScalarsystemBladeread-writemandatoryGenerate an alert for any informational condition on a blade. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for al…
1.3.6.1.4.1.2.3.51.2.4.2.3.17ScalarsystemIOread-writemandatoryGenerate an alert for any informational condition on I/O module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for…
1.3.6.1.4.1.2.3.51.2.4.2.3.18ScalarsystemStorageread-writemandatoryGenerate an alert for any informational condition on a Storage module. NOTE: This MIB object is for BCS only. NOTE: This object is valid when the alertMode obj…
1.3.6.1.4.1.2.3.51.2.4.2.3.19ScalarsystemPowerread-writemandatoryGenerate an alert for any informational condition on power module. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used f…
1.3.6.1.4.1.2.3.51.2.4.2.3.20ScalarsystemChassisread-writemandatoryGenerate an alert for any informational condition on chassis. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used for al…
1.3.6.1.4.1.2.3.51.2.4.2.3.21ScalarsystemFanread-writemandatoryGenerate an alert for any informational condition on cooling device. NOTE: This object is valid when the alertMode object is set enhanced(1) and should be used…
1.3.6.1.4.1.2.3.51.2.4.2.3.22ScalarsystemPWRDOread-writemandatoryGenerate an alert for any informational condition on power on and power off. NOTE: This object is valid when the alertMode object is set enhanced(1) and should…
1.3.6.1.4.1.2.3.51.2.4.2.4ScalaralertModeread-writemandatorySelects which alert categories will be displayed on the web interface, which alert category objects are accessible through SNMP, and which SNMP trap type an al…
1.3.6.1.4.1.2.3.51.2.4.3NodesecuritySettings
1.3.6.1.4.1.2.3.51.2.4.3.1ScalardataEncryptionread-writemandatoryIf enabled, all confidential data will be encrypted. The default value is disabled. NOTE: Once the data is encrypted, the only way to reverse this process is t…
1.3.6.1.4.1.2.3.51.2.4.3.2ScalartrespassWarningread-writemandatoryIf enabled, a customizable trespass warning message is displayed via the Web and CLI interfaces.
1.3.6.1.4.1.2.3.51.2.4.3.3ScalartrespassWarningDefaultread-writemandatoryReset the trespass warning to default value. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.3.4ScalartrespassMessageread-writemandatoryThe value of the trespass warning message.
1.3.6.1.4.1.2.3.51.2.4.4NodespClock
1.3.6.1.4.1.2.3.51.2.4.4.1ScalarspClockDateAndTimeSettingread-writemandatoryMM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set t…
1.3.6.1.4.1.2.3.51.2.4.4.2ScalarspClockTimezoneSettingread-writemandatoryMM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. The following table lists GMT offsets and associated DST information. DST is n…
1.3.6.1.4.1.2.3.51.2.4.5NodespIdentification
1.3.6.1.4.1.2.3.51.2.4.5.1ScalarspTxtIdread-writemandatoryMM text ID. NOTE: Do not put any 'space characters' at end of the ID.
1.3.6.1.4.1.2.3.51.2.4.9NodenetworkConfiguration
1.3.6.1.4.1.2.3.51.2.4.9.1NodenetworkInterfaces
1.3.6.1.4.1.2.3.51.2.4.9.1.1NodeextEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.1ScalarextEthernetInterfaceTyperead-onlymandatoryThe type of interface. Indicates 'Ethernet-1'.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.3ScalarextEthernetInterfaceHostNameread-writemandatoryContains the 64 byte null terminated DNS host name for this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.4ScalarextEthernetInterfaceIPAddressread-writemandatoryContains the IP address for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.5ScalarextEthernetInterfaceDataRateread-writemandatorySpecifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. Note that not all AMM hardware supports the 1G Auto spee…
1.3.6.1.4.1.2.3.51.2.4.9.1.1.6ScalarextEthernetInterfaceDuplexSettingread-writemandatorySpecifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. When a user selects the 1G Auto speed set…
1.3.6.1.4.1.2.3.51.2.4.9.1.1.7ScalarextEthernetInterfaceLAAread-writemandatorySpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value mu…
1.3.6.1.4.1.2.3.51.2.4.9.1.1.8ScalarextEthernetInterfaceDhcpEnabledread-writemandatoryDisable or enable DHCP on this interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.9ScalarextEthernetInterfaceGatewayIPAddressread-writemandatoryContains the IP address of the gateway/router for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.10ScalarextEthernetInterfaceBIAread-onlymandatorySpecifies the burned-in MAC (BIA) address.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.13ScalarextEthernetInterfaceMTUread-writemandatoryContains the Maximum Transmission Unit(MTU) for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.14ScalarextEthernetInterfaceSubnetMaskread-writemandatoryContains the subnet mask for the ethernet interface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16NodedhcpEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.1ScalardhcpHostNameread-onlymandatoryContains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.2ScalardhcpIPAddressread-onlymandatoryContains the IP address for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.3ScalardhcpGatewayIPAddressread-onlymandatoryContains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.4ScalardhcpSubnetMaskread-onlymandatoryContains the Subnet Mask for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.5ScalardhcpDomainNameread-onlymandatoryContains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.6ScalardhcpDHCPServerread-onlymandatoryContains the DHCP server IP address used to acquire the DHCP settings.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.7ScalardhcpPrimaryDNSServerread-onlymandatoryContains the Primary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.8ScalardhcpSecondaryDNSServerread-onlymandatoryContains the Secondary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.1.16.9ScalardhcpTertiaryDNSServerread-onlymandatoryContains the tertiary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.2.4.9.1.2NodeintEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.2.1ScalarintEthernetInterfaceTyperead-onlydeprecatedThe type of interface. Indicates 'PPP-1'. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.2ScalarintEthernetInterfaceEnabledread-writedeprecatedDisable or enable the internal ethernet interface. NOTE: To alter any of the configuration settings for the ethernet interface, the following procedure should …
1.3.6.1.4.1.2.3.51.2.4.9.1.2.4ScalarintEthernetInterfaceLocalIPAddressread-writedeprecatedContains the IP address for the MM side of the internal ethernet link. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.5ScalarintEthernetInterfaceDataRateread-onlydeprecatedSpecifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, or Auto. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.6ScalarintEthernetInterfaceDuplexSettingread-onlydeprecatedSpecifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This Mib object is deprecated and n…
1.3.6.1.4.1.2.3.51.2.4.9.1.2.7ScalarintEthernetInterfaceLAAread-writedeprecatedSpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value mu…
1.3.6.1.4.1.2.3.51.2.4.9.1.2.9ScalarintEthernetInterfaceGatewayIPAddressread-writedeprecatedContains the IP address of the gateway/router for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.10ScalarintEthernetInterfaceBIAread-onlydeprecatedSpecifies the burned-in MAC (BIA) address. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.13ScalarintEthernetInterfaceMTUread-onlydeprecatedContains the Maximum Transmission Unit (MTU) for the ethernet interface NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.2.14ScalarintEthernetInterfaceSubnetMaskread-writedeprecatedContains the subnet mask for the ethernet interface. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.4.9.1.3NodestandbyExtEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.3.1ScalarstandbyExtEthernetInterfaceTyperead-onlymandatoryThe type of interface. Indicates 'Ethernet-1'. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.3ScalarstandbyExtEthernetInterfaceHostNameread-writemandatoryContains the 64 byte null terminated DNS host name for this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.4ScalarstandbyExtEthernetInterfaceIPAddressread-writemandatoryContains the IP address for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.5ScalarstandbyExtEthernetInterfaceDataRateread-writemandatorySpecifies the data transfer rate to be used over the ethernet interface: 10Mb, 100Mb, 1G Auto or Auto. NOTE: This MIB object is only applicable to systems with…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.6ScalarstandbyExtEthernetInterfaceDuplexSettingread-writemandatorySpecifies the duplex settings for the data transfer rate to be used over the ethernet interface: Half, Full, or Auto. NOTE: This MIB object is only applicable …
1.3.6.1.4.1.2.3.51.2.4.9.1.3.7ScalarstandbyExtEthernetInterfaceLAAread-writemandatorySpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value mu…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.8ScalarstandbyExtEthernetInterfaceDhcpEnabledread-writemandatoryDisable or enable DHCP on this interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.9ScalarstandbyExtEthernetInterfaceGatewayIPAddressread-writemandatoryContains the IP address of the gateway/router for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.10ScalarstandbyExtEthernetInterfaceBIAread-onlymandatorySpecifies the burned-in MAC (BIA) address. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.13ScalarstandbyExtEthernetInterfaceMTUread-writemandatoryContains the Maximum Transmission Unit (MTU) for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.14ScalarstandbyExtEthernetInterfaceSubnetMaskread-writemandatoryContains the subnet mask for the ethernet interface. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.15ScalaradvancedFailoverread-writemandatoryUser can enable advanced failover. off : no standby network interface ipswap: Standby network interface, swap IPs during failover ipnoswap: Standby network int…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16NodestandbyDhcpEthernetInterface
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.1ScalarstandbyDhcpHostNameread-onlymandatoryContains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a …
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.2ScalarstandbyDhcpIPAddressread-onlymandatoryContains the IP address for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.3ScalarstandbyDhcpGatewayIPAddressread-onlymandatoryContains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.4ScalarstandbyDhcpSubnetMaskread-onlymandatoryContains the Subnet Mask for the ethernet interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.5ScalarstandbyDhcpDomainNameread-onlymandatoryContains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a st…
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.6ScalarstandbyDhcpDHCPServerread-onlymandatoryContains the DHCP server IP address used to acquire the DHCP settings. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.7ScalarstandbyDhcpPrimaryDNSServerread-onlymandatoryContains the Primary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.8ScalarstandbyDhcpSecondaryDNSServerread-onlymandatoryContains the Secondary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.3.16.9ScalarstandbyDhcpTertiaryDNSServerread-onlymandatoryContains the tertiary DNS server, assigned by the DHCP server. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.4NodeextEthernetInterfaceIPv6
1.3.6.1.4.1.2.3.51.2.4.9.1.4.1ScalarextEthernetInterfaceIPv6Typeread-onlymandatoryThe type of interface. Indicates 'Ethernet-1'.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.2ScalarextEthernetInterfaceIPv6Enabledread-writemandatoryThe current IPv6 enabled or disabled state of this AMM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this AM…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5NodeextEthernetInterfaceIPv6Config
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1NodeextEthernetInterfaceIPv6LocalAddress
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.1.1ScalarextEthernetInterfaceIPv6LinkLocalAddressread-onlymandatoryThe IPv6 link local IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2NodeextEthernetInterfaceIPv6StaticIPConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.1ScalarextEthernetInterfaceIPv6StaticIPConfigEnabledread-writemandatoryThe IPv6 static IP address enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.2ScalarextEthernetInterfaceIPv6StaticIPAddressread-writemandatoryThe IPv6 static IP address for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.3ScalarextEthernetInterfaceIPv6StaticIPAddressPrefixLenread-writemandatoryThe IPv6 static IP address prefix length for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.2.4ScalarextEthernetInterfaceIPv6StaticIPDefaultRouteread-writemandatoryThe IPv6 static IP address default route for the ethernet interface. NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3NodeextEthernetInterfaceIPv6AutoIPConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.1ScalarextEthernetInterfaceIPv6AutoIPConfigEnabledread-writemandatoryThe IPv6 automatic IP configuration enabled or disabled state for the ethernet interface. NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR o…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2NodeextEthernetInterfaceDHCPv6Config
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.1ScalarextEthernetInterfaceDHCPv6Enabledread-writemandatoryThe DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling e…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.2ScalarextEthernetInterfaceDHCPv6IPAddressread-onlymandatoryThe IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabl…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.4ScalarextEthernetInterfaceDHCPv6DomainNameread-onlymandatoryThe 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enable…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.5ScalarextEthernetInterfaceDHCPv6PrimaryDNSServerread-onlymandatoryThe primary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 s…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.6ScalarextEthernetInterfaceDHCPv6SecondaryDNSServerread-onlymandatoryThe secondary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.7ScalarextEthernetInterfaceDHCPv6TertiaryDNSServerread-onlymandatoryThe tertiary DNS server, assigned by the DHCPv6 server. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.2.8ScalarextEthernetInterfaceDHCPv6Serverread-onlymandatoryThe DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled is disabled or …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3NodeextEthernetInterfaceIPv6StatelessAutoConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.1ScalarextEthernetInterfaceIPv6StatelessAutoConfigEnabledread-writemandatoryThe IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, …
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2TableextEthernetInterfaceStatelessAutoConfigAddressesTablenot-accessiblemandatoryTable of stateless Auto-Config addresses entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1RowextEthernetInterfaceStatelessAutoConfigAddressesEntrynot-accessiblemandatoryStateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.1ColumnextEthernetInterfaceStatelessAutoConfigAddressesIndexread-onlymandatoryIndex for stateless Auto-Config addresses. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disabled…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.2ColumnextEthernetInterfaceStatelessAutoConfigAddressesread-onlymandatoryThe stateless Auto-Configuration IPv6 address. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently disa…
1.3.6.1.4.1.2.3.51.2.4.9.1.4.5.3.3.2.1.3ColumnextEthernetInterfaceStatelessAutoConfigAddressesPrefixLenread-onlymandatoryThe stateless Auto-Configration address prefix length. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is curren…
1.3.6.1.4.1.2.3.51.2.4.9.1.5NodestandbyExtEthernetInterfaceIPv6
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1NodestandbyEthernetInterfaceIPv6LocalAddress
1.3.6.1.4.1.2.3.51.2.4.9.1.5.1.1ScalarstandbyEthernetInterfaceIPv6LinkLocalAddressread-onlymandatoryThe IPv6 link local IP address for the standby AMM.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2NodestandbyEthernetInterfaceIPv6StaticIPConfig
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.1ScalarstandbyEthernetInterfaceIPv6StaticIPConfigEnabledread-onlymandatoryThe IPv6 static IP address state for the AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPConfigEnabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.2ScalarstandbyEthernetInterfaceIPv6StaticIPAddressread-writemandatoryThe IPv6 static IP address for the standby AMM NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.3ScalarstandbyEthernetInterfaceIPv6StaticIPAddressPrefixLenread-onlymandatoryThe IPv6 static IP address prefix length for the standyby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPAddressPrefixLen obj…
1.3.6.1.4.1.2.3.51.2.4.9.1.5.2.4ScalarstandbyEthernetInterfaceIPv6StaticIPDefaultRouteread-onlymandatoryThe IPv6 static IP address default route for the standby AMM. NOTE: This value may be altered through the extEthernetInterfaceIPv6StaticIPDefaultRoute object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3NodestandbyEthernetInterfaceDHCPv6Config
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.1ScalarstandbyEthernetInterfaceDHCPv6Enabledread-onlymandatoryThe DHCPv6 enabled or disabled state for the standby AMM. NOTE: This field may be altered through the extEthernetInterfaceDHCPv6Enabled object.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.2ScalarstandbyEthernetInterfaceDHCPv6IPAddressread-onlymandatoryThe IPv6 address for the standby AMM assigned by DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.3.4ScalarstandbyEthernetInterfaceDHCPv6DomainNameread-onlymandatoryThe 64 byte Domain Name for the standby AMM assigned by the DHCPv6 server.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4TablestandbyEthernetInterfaceStatelessAutoConfigAddressesTablenot-accessiblemandatoryTable of stateless Auto-Config addresses entries. NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or extEthernetInterfaceIPv6Enabled is currently d…
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1RowstandbyEthernetInterfaceStatelessAutoConfigAddressesEntrynot-accessiblemandatoryStateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.1ColumnstandbyEthernetInterfaceStatelessAutoConfigAddressesIndexread-onlymandatoryIndex for stateless Auto-Config addresses.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.2ColumnstandbyEthernetInterfaceStatelessAutoConfigAddressesread-onlymandatoryThe stateless Auto-Configuration IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.9.1.5.4.1.3ColumnstandbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLenread-onlymandatoryThe stateless Auto-Configration address prefix length.
1.3.6.1.4.1.2.3.51.2.4.9.1.10ScalarddnsStatusread-writemandatoryDynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configur…
1.3.6.1.4.1.2.3.51.2.4.9.1.11ScalarhostNameread-writemandatoryContains the DNS host name for this system. This object provides the exact same function as extEthernetInterfaceHostName
1.3.6.1.4.1.2.3.51.2.4.9.1.12ScalarstandbyHostNameread-writemandatoryContains the DNS host name for the standby. This object provides the exact same function as standbyExtEthernetInterfaceHostName and is only applicable to syste…
1.3.6.1.4.1.2.3.51.2.4.9.1.13ScalardomainNameread-writemandatoryThe user assigned DNS domain name.
1.3.6.1.4.1.2.3.51.2.4.9.1.14ScalarstandbyDomainNameread-writemandatoryThe user assigned DNS domain name of the standby. This is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.1.20NodevlanConfigure
1.3.6.1.4.1.2.3.51.2.4.9.1.20.1ScalarvlanGlobalStateread-writemandatoryThis object disables or enables the VLAN feature. The configuration objects for the VLAN are in the table, vlanTable. The default setting for this object is di…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.2ScalarvlanCommitTimeoutread-writemandatoryThis object is the number of minutes from the last VLAN-related object change until any non-committed changes will revert back to their previous settings. This…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.3ScalarvlanCommitStateread-writemandatoryThis object gives the status of whether there are VLAN-related changes pending that need to be committed, and allows a user to commit (save) any VLAN changes. …
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20TablevlanTablenot-accessiblemandatoryThis table contains the VLAN configuration objects. The default entry has an vlanEntryIndex equal to 1. The objects for this default entry are configurable. An…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1RowvlanEntrynot-accessiblemandatoryVLAN entries.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.1ColumnvlanEntryIndexread-onlymandatoryIndex for VLAN entry. If vlanEntryIndex is equal to 1, it is the Default VLAN entry and cannot be deleted.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.2ColumnvlanEntryVlanIdread-writemandatoryValid VLAN ID. Allowed values are 1..4094. If the entry is not valid, this object will have the value of 0. If this entry has the vlanEntryIndex value of 1 (de…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.3ColumnvlanEntryNameread-writemandatoryThis object allows the user to configure a text string name for this VLAN entry. This entry name is only used as a label for this entry.
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.4ColumnvlanEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to add a new VLAN entry are: 1. Create a new entry in this table vlanEntrySt…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.5ColumnvlanEntryStateread-writemandatoryThis object indicates whether this VLAN entry is enabled or disabled and allows the user to disable, enable or restart this entry except for the exceptions not…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.6ColumnvlanEntrySOLAccessread-writemandatoryThis object allows the user to set whether the VLAN for this entry will have access to the Serial Over LAN (SOL) interface. Only one VLAN entry may have this o…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.7ColumnvlanEntrycKVMAccessread-writemandatoryThis object allows the user to set whether the VLAN for this entry will have access to the installed cards for concurrent keyboard, video, and mouse (cKVM). On…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.8ColumnvlanEntryTaggingread-writemandatoryThis object allows the user to set whether VLAN tagging is enabled for this VLAN entry. This object is only configurable for the entry with the vlanEntryIndex …
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.9ColumnvlanEntryIOModuleAccessread-onlymandatoryThis read-only object indicates whether the VLAN for this entry will have access to the IO Modules. Only the VLAN entry with the vlanEntryIndex value of 1 will…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.10ColumnvlanEntryVlanDefaultread-writemandatoryThis object specifies which vlanTable entry is the 'default entry'. By default, the entry with the vlanEntryIndex value of 1 will have this object set to true(…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.31ColumnvlanEntryIPv4StaticAddressread-writemandatoryThis object sets the IP address for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the IP addr…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.32ColumnvlanEntryIPv4StaticGatewayread-writemandatoryThis object sets the IP address for the IP gateway for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.33ColumnvlanEntryIPv4StaticMaskread-writemandatoryThis object sets the subnet mask for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will have this object set to the subnet…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.51ColumnvlanEntryIPv4SubnetRoute1read-writemandatoryThis object sets the IP address of the subnet route 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.52ColumnvlanEntryIPv4SubnetRouteMask1read-writemandatoryThis object sets the subnet route mask 1 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object se…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.53ColumnvlanEntryIPv4SubnetRoute2read-writemandatoryThis object sets the IP address of the subnet route 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.54ColumnvlanEntryIPv4SubnetRouteMask2read-writemandatoryThis object sets the subnet route mask 2 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object se…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.55ColumnvlanEntryIPv4SubnetRoute3read-writemandatoryThis object sets the IP address of the subnet route 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have t…
1.3.6.1.4.1.2.3.51.2.4.9.1.20.20.1.56ColumnvlanEntryIPv4SubnetRouteMask3read-writemandatoryThis object sets the subnet route mask 3 for this VLAN entry. The entry with the vlanEntryIndex value of 1 (default VLAN entry) will always have this object se…
1.3.6.1.4.1.2.3.51.2.4.9.3NodetcpProtocols
1.3.6.1.4.1.2.3.51.2.4.9.3.1NodesnmpAgentConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.1.1ScalarsnmpSystemContactread-writemandatoryA NULL terminated 48 byte string that contains the SNMP agent contact name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.2ScalarsnmpSystemLocationread-writemandatoryA NULL terminated 48 byte string that contains the SNMP agent location name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.3ScalarsnmpSystemAgentTrapsDisableread-writemandatoryDisable or enable SNMP traps.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4NodesnmpAgentCommunityConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1TablesnmpCommunityTablenot-accessiblemandatoryTable of SNMP Community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1RowsnmpCommunityEntrynot-accessiblemandatorySNMP community entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.1ColumnsnmpCommunityEntryIndexread-onlymandatoryIndex for SNMP Agent Community entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.2ColumnsnmpCommunityEntryCommunityNameread-writemandatorySNMP Community entry name.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.3ColumnsnmpCommunityEntryCommunityIpAddress1read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.4ColumnsnmpCommunityEntryCommunityIpAddress2read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.5ColumnsnmpCommunityEntryCommunityIpAddress3read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.6ColumnsnmpCommunityEntryCommunityViewTyperead-writemandatoryAccess Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access lev…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.7ColumnsnmpCommunityEntryCommunityIpAddress4read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.8ColumnsnmpCommunityEntryCommunityIpAddress5read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.9ColumnsnmpCommunityEntryCommunityIpAddress6read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.10ColumnsnmpCommunityEntryCommunityIpAddress7read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.11ColumnsnmpCommunityEntryCommunityIpAddress8read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.12ColumnsnmpCommunityEntryCommunityIpAddress9read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.13ColumnsnmpCommunityEntryCommunityIpAddress10read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.14ColumnsnmpCommunityEntryCommunityIpAddress11read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.4.1.1.15ColumnsnmpCommunityEntryCommunityIpAddress12read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name. This field also allows two …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.5Scalarsnmpv1SystemAgentEnableread-writemandatoryDisable or enable the SNMPv1 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For exam…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.6Scalarsnmpv3SystemAgentEnableread-writemandatoryDisable or enable the SNMPv3 agent. NOTE: Restart the management module if this MIB object is changed with respect to the value at system bootup time. For exam…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9NodesnmpAgentUserProfileConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1TablesnmpUserProfileTablenot-accessiblemandatoryTable of SNMPv3 User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1RowsnmpUserProfileEntrynot-accessiblemandatorySNMP User Profile entries
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.1ColumnsnmpUserProfileEntryIndexread-onlymandatoryIndex for SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.3ColumnsnmpUserProfileEntryContextNameread-writemandatorySNMPv3 User Profile entry - Context name for users to access MIB objects. Note that context names can be duplicates and can be shared among users. Empty contex…
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.4ColumnsnmpUserProfileEntryAuthProtread-writemandatorySNMPv3 User Profile entry - Authentication Protocol supported by the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.6ColumnsnmpUserProfileEntryPrivProtread-writemandatorySNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before …
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.7ColumnsnmpUserProfileEntryPrivPasswordread-writemandatorySNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reasons.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.8ColumnsnmpUserProfileEntryViewTyperead-writemandatorySNMPv3 User Profile entry - Access level (Get, Set, and Traps) of the user.
1.3.6.1.4.1.2.3.51.2.4.9.3.1.9.1.1.9ColumnsnmpUserProfileEntryIpAddressread-writemandatorySNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.2NodednsConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.2.1ScalardnsEnabledread-writemandatoryDisable or enable the DNS agent. NOTE: To alter any of the configuration settings for the DNS agent, the following procedure should be used: (1) This object sh…
1.3.6.1.4.1.2.3.51.2.4.9.3.2.2ScalardnsServerIPAddress1read-writemandatoryContains the primary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.3ScalardnsServerIPAddress2read-writemandatoryContains the secondary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.4ScalardnsServerIPAddress3read-writemandatoryContains the tertiary DNS server IP address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.12ScalardnsServerIPv6Address1read-writemandatoryContains the primary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.13ScalardnsServerIPv6Address2read-writemandatoryContains the secondary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.14ScalardnsServerIPv6Address3read-writemandatoryContains the tertiary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.2.4.9.3.2.20ScalardnsPriorityread-writemandatoryTells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
1.3.6.1.4.1.2.3.51.2.4.9.3.3NodesmtpConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.3.1ScalarsmtpServerNameOrIPAddressread-writemandatoryA NULL terminated 64 byte string that contains the SMTP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.3.2ScalarattachmentsToEmailAlertsread-writemandatoryIndicates if the service information should be attached to an email alert.
1.3.6.1.4.1.2.3.51.2.4.9.3.3.3ScalarsmtpEmailDomainread-writemandatoryA NULL terminated string that contains the SMTP email domain. If this field is empty, the AMM IP address is used as the domain. However, some SMTP servers (e.g…
1.3.6.1.4.1.2.3.51.2.4.9.3.4NodetcpApplicationConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.4.1ScalartelnetInactivityTimeoutread-writemandatoryDefault is 120 seconds. Value of zero is no timeout. Max value is any positive 4 bytes value. Note that SSH also uses this timeout value to wait before disconn…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.2ScalarcommandModeInactivityTimeoutread-writemandatoryThe amount of time in seconds before the (Secure)TCP Command Mode times out. Default value of 0 means no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.3ScalarsecureCommandModeEnableread-writemandatorySet Secure TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.4ScalarcommandModeEnableread-writemandatorySet TCP Command Mode number of connections. AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode. A value of 0 means …
1.3.6.1.4.1.2.3.51.2.4.9.3.4.5ScalarslpAddrTyperead-writemandatorySet SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadcast value then the multicast address set in slpMulticastAddr…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.6ScalarslpMulticastAddrread-writemandatoryService Locator Protocol Multicast address
1.3.6.1.4.1.2.3.51.2.4.9.3.4.7ScalarslpEnableread-writemandatoryDisable/Enable Service Location Protocol. NOTE: Change to Service Location Protocol will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.9ScalartelnetEnableread-writemandatoryDisable/Enable telnet. NOTE: Change to telnet enable/disable will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.10ScalarsshEnableread-writemandatoryDisable/Enable SSH.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.11ScalarsshVersionread-writemandatoryWhen SSH is enabled, this object allows the user to configure whether the SSH server accepts all versions of client connections or whether it restricts the con…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.15ScalarsslServerEnableread-writemandatoryDisable/Enable SSL Server.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.16ScalarsslClientEnableread-writemandatoryDisable/Enable SSL Client. If no valid client or server certificate is in place, SSL client will not be allowed to set to enable.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.17ScalarftpEnableread-writemandatoryDisable/Enable FTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.19ScalartftpEnableread-writemandatoryDisable/Enable TFTP.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.20ScalarsmashTelnetEnableread-writemandatoryDisable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over Telnet. This option is not available on all systems.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.21ScalarsmashSshEnableread-writemandatoryDisable/Enable SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. A valid SSH server key must be installed before e…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.22ScalartftpCreateEmptyFileread-writedeprecatedThis MIB object is no longer a requirement for TFTP and has been deprecated.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.23ScalarftpTimeoutread-writemandatoryThe amount of time before FTP times out. Default is 300 seconds. Value of zero is no timeout. Max value is any positive 4 byte value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.24ScalarrdEnableread-writemandatoryDisable/Enable Remote Disk. NOTE: Change to Remote Disk will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.25ScalarrdocEnableread-writemandatoryDisable/Enable Remote Disk on Card. NOTE: Change to Remote Disk on Card will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.26ScalarkvmEnableread-writemandatoryDisable/Enable KVM. NOTE: Change to KVM will take effect after the next restart of the MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27NodemmSshServerConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1TablemmSshServerHostKeyTablenot-accessiblemandatoryA table that contains per public/private host key pair information.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1RowmmSshServerHostKeyEntrynot-accessiblemandatoryA list of information about a particular public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.1ColumnmmSshServerHostKeyIndexread-onlymandatoryThe index of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.2ColumnmmSshServerHostKeyTyperead-onlymandatoryThe type of the public/private host key pair.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.3ColumnmmSshServerHostKeySizeread-onlymandatoryThe size of the public/private host key pair. NOTE: The AMM supports only the bits2048 value.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.1.1.4ColumnmmSshServerHostKeyFingerprintread-onlymandatoryThe RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure S…
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.2ScalarmmSshServerHostKeyGenerateread-writemandatoryInitiate the new Host Keys generation process for the AMM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.27.3ScalarmmSshServerHostKeyGenerateProgressread-onlymandatoryIndicate the progress of the key generation process.
1.3.6.1.4.1.2.3.51.2.4.9.3.4.28ScalarrpEnableread-writemandatoryDisable/Enable Remote Presence.
1.3.6.1.4.1.2.3.51.2.4.9.3.5NodetcpPortAssignmentCfg
1.3.6.1.4.1.2.3.51.2.4.9.3.5.1ScalartcpPortsRestoreDefaultread-writemandatoryReset all ports to default value. http: 80 https: 443 telnet: 23 ssh: 22 SNMP agent: 161 SNMP trap: 162 TCP Command Mode: 6090 Secure TCP Command Mode: 6091 Re…
1.3.6.1.4.1.2.3.51.2.4.9.3.5.2ScalarhttpPortAssignmentread-writemandatoryHTTP port number. Default value is 80. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.3ScalarhttpsPortAssignmentread-writemandatorySSL port number. Default value is 443. Once changed, the URL's have to include :port at the end.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.4ScalartelnetPortAssignmentread-writemandatoryTelnet port number. Default value is 23. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.5ScalarsshPortAssignmentread-writemandatorySSH port number. Default value is 22.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.6ScalarsnmpAgentPortAssignmentread-writemandatorySNMP Agent port number. Default value is 161. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.7ScalarsnmpTrapsPortAssignmentread-writemandatorySNMP Traps port number. Default value is 162. Changes take effect after several seconds.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.8ScalarcommandModePortAssignmentread-writemandatoryTCP Command Mode port number. Default value is 6090. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.9ScalarsecureCommandModePortAssignmentread-writemandatorySecure TCP Command Mode port number. Default value is 6091. Change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.10ScalarrdPortAssignmentread-writedeprecatedRemote Disk port number. Default value is 1044. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the …
1.3.6.1.4.1.2.3.51.2.4.9.3.5.11ScalarrdocPortAssignmentread-writedeprecatedRemote Disk-on-Card port number. Default value is 1045. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced…
1.3.6.1.4.1.2.3.51.2.4.9.3.5.12ScalarkvmPortAssignmentread-writedeprecatedRemote KVM port number. Default value is 3900. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been replaced by the r…
1.3.6.1.4.1.2.3.51.2.4.9.3.5.13ScalarftpPortAssignmentread-writemandatoryFTP port number. Default value is 21. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.14ScalarftpDataPortAssignmentread-writemandatoryFTP Data port number. Default value is 20. Port change will take effect immediately.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.15ScalartftpPortAssignmentread-writemandatoryTFTP port number. Default value is 69.
1.3.6.1.4.1.2.3.51.2.4.9.3.5.17ScalarsmashTelnetPortAssignmentread-writemandatoryThe port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over telnet. Default value is 50023. Change will take …
1.3.6.1.4.1.2.3.51.2.4.9.3.5.18ScalarsmashSshPortAssignmentread-writemandatoryThe port number for SMASH CLP (System Management Architecture for Server Hardware Command Line Protocol) over SSH. Default value is 50022. This option is not a…
1.3.6.1.4.1.2.3.51.2.4.9.3.5.19ScalarslpPortAssignmentread-writemandatoryService Location Protocol port number. Default value is 427. NOTE: This value is normally required to be 427 to interoperate properly with other SLP enabled ap…
1.3.6.1.4.1.2.3.51.2.4.9.3.5.20ScalarsdsPortAssignmentread-writedeprecatedStorage description service port number. Default value is 1046. MM has to be reset for change to take effect. NOTE: This mib object is deprecated and has been …
1.3.6.1.4.1.2.3.51.2.4.9.3.5.21ScalarrpPortAssignmentread-writemandatoryRemote Presence port. Default value is 3900. This port cannot be disabled since it is the single service entry point for all the services provided by AMM RPSer…
1.3.6.1.4.1.2.3.51.2.4.9.3.6NodeldapClientCfg
1.3.6.1.4.1.2.3.51.2.4.9.3.6.1ScalarldapServer1NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.2ScalarldapServer1PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.3ScalarldapServer2NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.4ScalarldapServer2PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.5ScalarldapServer3NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.6ScalarldapServer3PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.7ScalarldapRootDNread-writemandatoryA NULL terminated 255 byte string that contains the distinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.8ScalarldapUserSearchBaseDNread-writedeprecatedAs part of the user authentication process, it is necessary to search the LDAP server for one or more attributes associated with a particular user. Any search …
1.3.6.1.4.1.2.3.51.2.4.9.3.6.9ScalarldapGroupFilterread-writemandatoryThis filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Other…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.10ScalarldapBindingMethodread-writemandatoryOn initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or …
1.3.6.1.4.1.2.3.51.2.4.9.3.6.11ScalarldapClientAuthenticationDNread-writemandatoryThe initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client …
1.3.6.1.4.1.2.3.51.2.4.9.3.6.12ScalarldapClientAuthenticationPasswordread-writemandatoryThe client authentication password
1.3.6.1.4.1.2.3.51.2.4.9.3.6.13ScalarldapUIDsearchAttributeread-writemandatoryWhen the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aime…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.14ScalarldapGroupSearchAttributeread-writemandatoryWhen the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is req…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.15ScalarldapLoginPermissionAttributeread-writemandatoryWhen a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissio…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.16ScalarldapUseDNSOrPreConfiguredServersread-writemandatoryThe MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.17ScalarldapDomainSourceread-writedeprecatedThe DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the followi…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.18ScalarldapSearchDomainread-writedeprecatedThis parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.19ScalarldapServiceNameread-writedeprecatedThe DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default val…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.20ScalarldapRBSModelCfgread-writemandatoryThere are two mechanisms to authenticate and authorize users on the AMM when using an LDAP-enabled server. The first mechanism (oldPermissionString), also know…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.21ScalarldapTargetNameread-writemandatoryWhen administrator chooses Enhanced Role Based Security authentication model, he can associate one AMM with one managed target object in Snap-in (one tool to c…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.22ScalarldapAuthCfgread-writemandatoryIf ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LD…
1.3.6.1.4.1.2.3.51.2.4.9.3.6.23ScalarldapForestNameread-writemandatoryLDAP Forest Name. Note: LDAP Forest Name is only for Active Directory environment.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.24ScalarldapDomainNameread-writemandatoryA NULL terminated 255 byte string that contains the LDAP Domain Name.
1.3.6.1.4.1.2.3.51.2.4.9.3.6.25ScalarldapServer4NameOrIPAddressread-writemandatoryA NULL terminated 255 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.2.4.9.3.6.26ScalarldapServer4PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.7NodeuplinkCheckConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.7.1ScalaruplinkCheckEnabledread-writemandatoryDisable or enable network uplink checking for physical detection. NOTE: This MIB object is only applicable to systems with a standby MM.
1.3.6.1.4.1.2.3.51.2.4.9.3.7.2ScalaruplinkCheckDelayread-writemandatoryDelay, in minutes (1-2880), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only a…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.3ScalarlogicalUplinkDestinationread-writemandatoryDestination IP for MM to check its logical link. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is only applic…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.4ScalarlogicalUplinkCheckEnabledread-writemandatoryDisable or enable network uplink checking for logical detection. logicalUplinkDestination must be set to a non-zero IP Address before enable logical uplink che…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.5ScalarlogicalUplinkCheckDelayread-writemandatoryDelay, in minutes(1-2880), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only app…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.6ScalarphysicalUplinkCheckDelayInSecsread-writemandatoryDelay, in seconds(10-172800), between discovery of a failed network uplink and the subsequent MM failover for physical detection. NOTE: This MIB object is only…
1.3.6.1.4.1.2.3.51.2.4.9.3.7.7ScalarlogicalUplinkCheckDelayInSecsread-writemandatoryDelay, in seconds(60-172800), between discovery of a failed network uplink and the subsequent MM failover for logical detection. NOTE: This MIB object is only …
1.3.6.1.4.1.2.3.51.2.4.9.3.7.8ScalarlogicalUplinkIPv6Destinationread-writemandatoryDestination IP for MM to check its logical link using IPv6. Specify a non-zero IP Address in order to enable logical uplink checking. NOTE: This MIB object is …
1.3.6.1.4.1.2.3.51.2.4.9.3.7.9ScalarlogicalUplinkFailoverPolicyread-writemandatoryDetermines when to failover if both an IPv4 and IPv6 destination have been configured. If set to 'either' the system will failover if either of the destination…
1.3.6.1.4.1.2.3.51.2.4.9.3.8NodentpConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.8.1ScalarntpEnableread-writemandatoryDisable/Enable the NTP client. The client will update the AMM system clock at the frequency specified.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.2ScalarntpIpAddressHostnameread-writemandatoryNTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.3ScalarntpUpdateFrequencyread-writemandatoryThe frequency in minutes that the NTP service runs. The value range is 0 to 45000. If the NTP update frequency is set to 0, the AMM clock can only be synchroni…
1.3.6.1.4.1.2.3.51.2.4.9.3.8.4ScalarntpLastUpdateread-onlymandatoryThe date and time that the NTP server last updated the system clock.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.5ScalarntpUpdateClockread-writemandatoryUpdate the AMM system clock with the specified NTP server. A valid NTP server must be configured first.
1.3.6.1.4.1.2.3.51.2.4.9.3.8.6ScalarntpAuthEntryread-writemandatoryThe NTP v3 authentication entry to be used for time sync with a secure NTP server. The format of an authentication entry is <key index> <key type> <key>. <key …
1.3.6.1.4.1.2.3.51.2.4.9.3.8.7ScalarntpAuthEnableread-writemandatoryEnables/Disables NTP v3 authentication
1.3.6.1.4.1.2.3.51.2.4.9.3.9NodesyslogConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.9.1ScalarsyslogSevFilterLevelread-writemandatorysyslogSevFilterLevel error/warning/information .
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2NodesyslogCollectorConfig
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1TablesyslogCollectorTablenot-accessiblemandatoryTable of Syslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1RowsyslogCollectorEntrynot-accessiblemandatorySyslog Collector entries
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.1ColumnsyslogCollectorIndexread-onlymandatoryIndex for Syslog Collector entry.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.2ColumnsyslogCollectorHostnameOrIpAddressread-writemandatorySyslog Collector IP address or host name.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.3ColumnsyslogCollectorPortread-writemandatorySyslog Collector port number.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.2.1.1.4ColumnsyslogCollectorEnableread-writemandatorySyslog Collector enable/disable.
1.3.6.1.4.1.2.3.51.2.4.9.3.9.3ScalarsyslogTestPacketread-writemandatoryGenerate a test syslog packet. This will send a test syslog to all configured and enabled syslog collectors to assist in validating the configuration. NOTE: Va…
1.3.6.1.4.1.2.3.51.2.4.10NodesolConfiguration
1.3.6.1.4.1.2.3.51.2.4.10.1NodesolGlobalConfig
1.3.6.1.4.1.2.3.51.2.4.10.1.1ScalarsolEnableread-writemandatoryDisable/Enable SOL dynamically.
1.3.6.1.4.1.2.3.51.2.4.10.1.2ScalarsolVlanIdread-writemandatoryThis is the virtual LAN ID for the internal management network between the MM and the Blade System Management Processors (BSMPs). The range of valid VLAN ID's …
1.3.6.1.4.1.2.3.51.2.4.10.1.3ScalarsolAccumulateTimeoutread-writemandatoryThis value specifies how much time in millisecond SOL to buffer data before sending the next SOL packet since the last SOL packet was transmitted. Valid value …
1.3.6.1.4.1.2.3.51.2.4.10.1.4ScalarsolCharSendThresholdread-writemandatoryThis value specifies how many characters SOL to buffer before sending the next SOL packet since the last SOL packet was transmitted. Valid value is from 1 to 2…
1.3.6.1.4.1.2.3.51.2.4.10.1.5ScalarsolRetryread-writemandatoryRetry count. Valid value from 0-7. 0 means no retries after packet is transmitted. Packet will be dropped if no ACK/NACK received by the time retries expired.
1.3.6.1.4.1.2.3.51.2.4.10.1.6ScalarsolRetryIntervalread-writemandatoryRetry Interval in 10 ms increment. Sets the time that the SOL will wait before the first retry and the time between retries when sending SOL packets to the rem…
1.3.6.1.4.1.2.3.51.2.4.10.1.7ScalarsolExitToCliKeySeqread-writemandatoryThis is the keystroke sequence used to escape out of SOL session and back to CLI console. This sequence must have at least one character. The caret symbol (^) …
1.3.6.1.4.1.2.3.51.2.4.10.1.8ScalarsolResetBladeKeySeqread-writemandatoryThis is the keystroke sequence used to reset the blade while in SOL session console. This sequence must have at least one character. The caret symbol (^) has a…
1.3.6.1.4.1.2.3.51.2.4.10.2NodesolBladeConfig
1.3.6.1.4.1.2.3.51.2.4.10.2.1TablesolBladeTablenot-accessiblemandatorySOL Blade configuration table.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1RowsolBladeEntrynot-accessiblemandatorySOL Blade table entry
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.1ColumnsolBladeIndexread-onlymandatorySOL Blade table index.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.2ColumnsolBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.3ColumnsolBladeEnableread-writemandatoryDisable or enable a SOL on a blade.
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.4ColumnsolBladeIpAddrread-onlymandatoryIP address of the blade derived from the IP address range for the blade system management processors on the blades. NOTE: The IPv6 address for a blade can be v…
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.5ColumnsolBladeSessionStatusread-onlymandatoryStatus of a blade SOL session: solSessionNotReady: no SOL session connected to the blade. solSessionReady: there is an SOL session to the blade. solSessionActi…
1.3.6.1.4.1.2.3.51.2.4.10.2.1.1.6ColumnsolBladeCapabilityread-onlymandatoryDisplay whether or not the blade support SOL feature.
1.3.6.1.4.1.2.3.51.2.4.11NodechassisInternalNetwork
1.3.6.1.4.1.2.3.51.2.4.11.1ScalarcinsSupportedread-onlymandatoryNumber of Chassis Internal Network (CIN) definitions supported. Currently a maximum of 14 CIN definitions can be supported.
1.3.6.1.4.1.2.3.51.2.4.11.2ScalarcinGlobalEnableread-writemandatoryDisable/Enable Chassis Internal Network (CIN) function dynamically. Enabled: AMM reads the CIN entries. For each enabled entry, - If the CIN VLAN ID is new and…
1.3.6.1.4.1.2.3.51.2.4.11.3TablecinTablenot-accessiblemandatoryChassis Internal Network (CIN) configuration table.
1.3.6.1.4.1.2.3.51.2.4.11.3.1RowcinEntrynot-accessiblemandatoryChassis Internal Network (CIN) table entry.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.1ColumncinIndexread-onlymandatoryChassis Internal Network (CIN) table index.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.2ColumncinDefExistsread-onlymandatoryIndicates if a Chassis Internal Network (CIN) definition exists for this index or not.
1.3.6.1.4.1.2.3.51.2.4.11.3.1.3ColumncinDeleteread-writemandatoryDelete Chassis Internal Network (CIN) definition. Works like CIN entry disabled. However, the entry is also deleted. NOTE: Value returned for the GET command i…
1.3.6.1.4.1.2.3.51.2.4.11.3.1.4ColumncinEnableread-writemandatoryDisable or enable a Chassis Internal Network (CIN) definition. Enabled: AMM reads the entry and creates a new CIN interface if the CIN VLAN ID is new and does …
1.3.6.1.4.1.2.3.51.2.4.11.3.1.5ColumncinIdread-writemandatoryThis is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for the internal management network between the Management Module, I/O Module, and the blade O…
1.3.6.1.4.1.2.3.51.2.4.11.3.1.6ColumncinIpAddressread-writemandatoryChassis Internal Network (CIN) IP address. Restrictions: - CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0. - Multiple IP addresse…
1.3.6.1.4.1.2.3.51.2.4.11.3.1.7ColumncinIpv6Addressread-writemandatoryChassis Internal Network (CIN) IPv6 address NOTE: When ipv4 is enable on one interface,this column will display all zero IPv6 address.
1.3.6.1.4.1.2.3.51.2.4.11.4NodecinStatus
1.3.6.1.4.1.2.3.51.2.4.11.4.1TablecinStatusTablenot-accessiblemandatoryTable of Chassis Internal Network (CIN) status entry information.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1RowcinStatusEntrynot-accessiblemandatoryChassis Internal Network (CIN) status table entry.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.1ColumncinStatusIndexread-onlymandatoryThe Chassis Internal Network (CIN) status log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.4.11.4.1.1.2ColumncinStatusStringread-onlymandatoryStatus of a Chassis Internal Network (CIN) connection. For example: Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operati…
1.3.6.1.4.1.2.3.51.2.4.11.5TablecinPortConfigTablenot-accessiblemandatoryChassis Internal Network (CIN) configuration table for viewing and configuring the protocol port information for a particular CIN entry.
1.3.6.1.4.1.2.3.51.2.4.11.5.1RowcinPortConfigEntrynot-accessiblemandatoryChassis Internal Network (CIN) entry for viewing and configuring the protocol port information for a particular CIN entry.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.1ColumncinPortConfigCINIndexread-onlymandatoryThe identifier for the particular CIN configuration that these protocol port definitions are associated with. This object is the same as the cinIndex value in …
1.3.6.1.4.1.2.3.51.2.4.11.5.1.2ColumncinPortConfigIndexread-onlymandatoryThe identifier of a particular CIN protocol port configuration for a given CIN configuration as specified by cinPortConfigCINIndex. There can be up to 16 uniqu…
1.3.6.1.4.1.2.3.51.2.4.11.5.1.3ColumncinPortConfigProtocolIDread-writemandatoryIndicates whether the port protocol definition is for a TCP or UDP port. If the value of notDefined(3) is returned, the entry has yet to be configured.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.4ColumncinPortConfigExternalPortread-writemandatoryThe external port number specified for this port protocol definition, ranging from 1 to 65,534.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.5ColumncinPortConfigInternalPortread-writemandatoryThe internal port number specified for this port protocol definition, ranging from 1 to 65,534.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.6ColumncinPortConfigEnableread-writemandatoryThe status of this port protocol definition.
1.3.6.1.4.1.2.3.51.2.4.11.5.1.7ColumncinPortConfigDirectionread-writemandatoryThe traffic direction specified for this port protocol definition.
1.3.6.1.4.1.2.3.51.2.4.15NodeconfigurationManagement
1.3.6.1.4.1.2.3.51.2.4.15.1ScalarsaveConfigurationToChassisread-writemandatorySave the configuration settings from the AMM to the chassis. This operation may take several seconds. The input values for the SET command when AMM is installe…
1.3.6.1.4.1.2.3.51.2.4.15.2ScalarrestoreConfigurationFromChassisread-writemandatoryRestore the configuration settings to the AMM from the BladeCenter chassis. NOTE: This MIB object is for AMM only and the value returned for the GET command is…
1.3.6.1.4.1.2.3.51.2.4.15.3ScalarautoReadConfigInNewChassisread-writemandatoryThe AMM will automatically read configuration settings from the midplane every time the AMM is inserted into a new chassis. NOTE: This MIB object is for AMM on…
1.3.6.1.4.1.2.3.51.2.5NodetelcoManagement
1.3.6.1.4.1.2.3.51.2.5.1NodetelcoAlarmReq
1.3.6.1.4.1.2.3.51.2.5.1.1ScalartelcoAlarmSetread-writemandatoryCreate a software alarm. An input octet string consists of the alarm severity level and the alarm description (40 bytes max). The following severity levels are…
1.3.6.1.4.1.2.3.51.2.5.1.2ScalartelcoAlarmAckread-writemandatoryAcknowledge an alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255)…
1.3.6.1.4.1.2.3.51.2.5.1.3ScalartelcoAlarmClearread-writemandatoryClear an active alarm. An input octet string consists of the alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where: m : Module ID value of decimal digits(1-255…
1.3.6.1.4.1.2.3.51.2.5.3NodetelcoHWManagement
1.3.6.1.4.1.2.3.51.2.5.3.1NodetappowerReq
1.3.6.1.4.1.2.3.51.2.5.3.1.1Scalartappoweronoffread-writemandatoryTelco Alarm Panel power on or power off. If powering off a currently powered on Telco Alarm Panel, then all LEDs of this request card will be reset to OFF and …
1.3.6.1.4.1.2.3.51.2.5.3.2NodencReq
1.3.6.1.4.1.2.3.51.2.5.3.2.1TablencReqTablenot-accessibledeprecatedTable of the Network Clock Module Operations. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter H…
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1RowncReqEntrynot-accessibledeprecatedNetwork Clock Module Power ON/OFF entry. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT onl…
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.1ColumnncReqIndexread-onlydeprecatedNetwork Clock Module Request index. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT only.
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.2ColumnncReqBayNumberread-onlydeprecatedNetwork Clock Module Request Bay number. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BladeCenter HT onl…
1.3.6.1.4.1.2.3.51.2.5.3.2.1.1.3ColumnncReqPoweronoffread-writedeprecatedRequest to power on/off for the specified Network Clock Module. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is…
1.3.6.1.4.1.2.3.51.2.5.127NodetelcoOEM
1.3.6.1.4.1.2.3.51.2.5.127.1ScalartelcoOEMsread-onlymandatoryA bitmap of information about the contents of this subtree. The bitmap is a variable length string containing a list of 1's and 0's. Every bit that is set to 1…
1.3.6.1.4.1.2.3.51.2.7NoderestartReset
1.3.6.1.4.1.2.3.51.2.7.4ScalarrestartSPImmediatelyread-writemandatoryRestart the MM immediately. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.7.5ScalarrestartStandbyMMread-writemandatoryRestarts the Standby MM from the Primary MM. NOTE: Value returned for the GET command is meaningless for this MIB object. NOTE: This mib object is only applica…
1.3.6.1.4.1.2.3.51.2.7.7ScalarswitchOverRedundantMMread-writemandatorySwitch over to the redundant Management Module. The failover will not occur if the standby or primary MM is in flashing mode. NOTE: Value returned for the GET …
1.3.6.1.4.1.2.3.51.2.7.20ScalarresetSPConfigAndRestartread-writemandatoryWill cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. …
1.3.6.1.4.1.2.3.51.2.7.21ScalarresetSPConfigAndRestartSaveLogsread-writemandatoryWill cause all the MM information to be reset to it's initial factory defaults (all previous configuration information is lost) and the MM will be re-started. …
1.3.6.1.4.1.2.3.51.2.22Nodeblades
1.3.6.1.4.1.2.3.51.2.22.1NodeprocessorBlade
1.3.6.1.4.1.2.3.51.2.22.1.1ScalarbladeMediaTrayBladeIdread-writemandatoryAllocate the media tray to a blade of a BladeCenter system. On a get command, a blade ID of 0x00 means that no blade is currently using the device. A set comma…
1.3.6.1.4.1.2.3.51.2.22.1.2ScalarbladeKVMBladeIdread-writemandatoryAllocate the keyboard, video, and mouse ports (KVM) to a blade of a blade runner system. On a get command, a blade ID of 0x00 means that no blade is currently …
1.3.6.1.4.1.2.3.51.2.22.1.3TablebladeBootSequenceTablenot-accessiblemandatoryTable of blade boot sequence information. Contains the boot sequence information for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.3.1RowbladeBootSequenceEntrynot-accessiblemandatoryBoot sequence entry
1.3.6.1.4.1.2.3.51.2.22.1.3.1.1ColumnbootSequenceIndexread-onlymandatoryBlade boot sequence index.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.2ColumnbootSequenceBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.3ColumnbootSequenceBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.4ColumnbootSequenceBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.5ColumnbootSequenceBladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.22.1.3.1.6ColumnbootSequenceBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.3.1.7ColumnbootSequence1read-writemandatoryThe boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, a…
1.3.6.1.4.1.2.3.51.2.22.1.3.1.8ColumnbootSequence2read-writemandatoryThe boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, a…
1.3.6.1.4.1.2.3.51.2.22.1.3.1.9ColumnbootSequence3read-writemandatoryThe boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, a…
1.3.6.1.4.1.2.3.51.2.22.1.3.1.10ColumnbootSequence4read-writemandatoryThe boot device for this blade boot sequence. Note that some types of blades don't support floppy disk drive. It is recommended that all boot sequence 1,2 3, a…
1.3.6.1.4.1.2.3.51.2.22.1.4NodebladeRemoteControl
1.3.6.1.4.1.2.3.51.2.22.1.4.1TablebladeRemoteControlTablenot-accessiblemandatoryTable of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1RowbladeRemoteControlEntrynot-accessiblemandatoryRemote power control entry
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.1ColumnremoteControlIndexread-onlymandatoryBlade remote power control index.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.2ColumnremoteControlBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.3ColumnremoteControlBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.4ColumnremoteControlBladePowerStateread-onlymandatoryThe power state for blade. 0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.5ColumnremoteControlBladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.6ColumnremoteControlBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.7ColumnremotePowerControlEnableread-writemandatoryBlade remote power control enablement status.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.8ColumnremoteMediaTrayControlEnableread-writemandatoryBlade media tray enablement status.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.9ColumnremoteKVMControlEnableread-writemandatoryBlade KVM enablement status. Note that some types of blades don't support KVM
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.10ColumnremoteWakeOnLanControlEnableread-writemandatoryBlade Wake On LAN enablement status. If WOL is not supported by the blade, it displays 'notApplicable' and WOL can not be enabled or disabled.
1.3.6.1.4.1.2.3.51.2.22.1.4.1.1.11ColumnremoteMediaTraySwitchEnableread-writemandatoryBlade Remote Media Tray Switch enablement status. If the remote disk feature is disabled, this OID cannot be set.
1.3.6.1.4.1.2.3.51.2.22.1.4.2NodebladePolicy
1.3.6.1.4.1.2.3.51.2.22.1.4.2.1ScalarbladePolicyPowerControlEnableread-writemandatoryBlade remote power control enablement status policy.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.2ScalarbladePolicyMediaTrayControlEnableread-writemandatoryBlade media tray enablement status policy.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.3ScalarbladePolicyKVMControlEnableread-writemandatoryBlade KVM enablement status policy. Note that some types of blades don't support KVM.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.4ScalarbladePolicyWakeOnLanControlEnableread-writemandatoryBlade Wake On LAN enablement status policy. The notApplicable(255) enumeration is not valid for SET operations. NOTE: Value returned for the GET command is mea…
1.3.6.1.4.1.2.3.51.2.22.1.4.2.5ScalarbladePolicyMediaTraySwitchEnableread-writemandatoryBlade Remote Media Tray Switch enablement status policy. If the remote disk feature is disabled, this OID cannot be set.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.6ScalarbladePolicyMultipleRemoteVideoEnableread-writemandatoryBlade multiple remote video sessions enablement status policy. A maximum users can access the video of the same blade from remote console when set to enabled. …
1.3.6.1.4.1.2.3.51.2.22.1.4.2.7ScalarbladePolicyAutoPowerOnread-writemandatoryBlade auto-power on policy. - restore: all blades will be powered on which were previously on. - auto: all blades will automatically be powered on when power i…
1.3.6.1.4.1.2.3.51.2.22.1.4.2.8ScalarbladePolicyDisconnectionModeread-writemandatoryBlade disconnection mode. - noDisconnection: If the blade is already serving a maximum number of users, the requester can't get connection - forcedisconnection…
1.3.6.1.4.1.2.3.51.2.22.1.4.2.9ScalarbladePolicySessionTimeOutread-writemandatoryClient session time out in minutes. If there is no remote presence activity, after that time, the session will be closed authomatically.
1.3.6.1.4.1.2.3.51.2.22.1.4.2.10ScalarbladePolicyRequestTimeOutread-writemandatoryClient connection request time out in seconds. In case of single session mode, if the requested user does not respond within this timeout, the user request wil…
1.3.6.1.4.1.2.3.51.2.22.1.4.2.11ScalarbladePolicyRetryTimeOutread-writemandatoryClient connection retry time out in seconds. It is possible that the current blade access is negotiated by other 2 clients. If the third comes it will need to …
1.3.6.1.4.1.2.3.51.2.22.1.4.2.12ScalarbladePolicySessionLostTimeOutread-writemandatoryClient session lost in minutes. Amount of time before session closes due to loss of session, and user may regain control. This may happen if for example the cl…
1.3.6.1.4.1.2.3.51.2.22.1.5NodebladeMonitors
1.3.6.1.4.1.2.3.51.2.22.1.5.1TablebladeSystemStatusTablenot-accessiblemandatoryTable of blade status information.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1RowbladeSystemStatusEntrynot-accessiblemandatoryBlade system status entry
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.1ColumnbladeStatusIndexread-onlymandatoryBlade system status index.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.2ColumnbladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.3ColumnbladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.4ColumnbladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.5ColumnbladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.6ColumnbladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.7ColumnbladeRemotePowerEnableread-onlymandatoryRemote power state for the blade. 0x01 indicates enabled.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.8ColumnbladeRemoteMediaTrayEnableread-onlymandatoryRemote Media Tray state for the blade. 0x01 indicates enabled.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.9ColumnbladeRemoteKVMEnableread-onlymandatoryRemote keyboard/video/monitor state for the blade. 0x01 indicates enabled. Note that some types of blades don't support KVM
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.10ColumnbladeConnectionTyperead-onlymandatoryConnection type of the expansion card number one.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.11ColumnbladeOwnsKVMread-onlymandatoryIndicates whether the MM owns the KVM. 0 = false, 1 = true. Note that some types of blades don't support KVM
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.12ColumnbladeOwnsMediaTrayread-onlymandatoryIndicates whether the blade owns the Media Tray. 0 = false, 1 = true.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.13ColumnbladeRemoteWakeOnLanEnableread-onlymandatoryRemote wake on LAN state for the blade. 0x01 indicates enabled.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.14ColumnbladeServerExpansionread-onlymandatoryThis shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.15ColumnbladeWidthread-onlymandatoryThe width of the blade including any supplement blade attached to it
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.16ColumnbladeSupportCapacityOnDemandread-onlydeprecatedThis shows whether this blade support Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.17ColumnbladeServerExpansion2read-onlymandatoryThis shows whether this blade has an expansion board attached. A yes column indicates that an expansion board is installed for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.21ColumnbladecKVMStatusread-onlymandatoryThis shows whether this blade has a concurrent keyboard, video, and mouse (cKVM) card installed and the status of cKVM on the blade. Not present: A cKVM card i…
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.22ColumnbladeConnectionType2read-onlymandatoryConnection type of the expansion card number 2.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.23ColumnbladeConnectionType3read-onlymandatoryConnection type of the expansion card number 3.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.24ColumnbladeConnectionType4read-onlymandatoryConnection type of the expansion card number 4.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.25ColumnbladeConnectionType5read-onlymandatoryConnection type of the expansion card number 5.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.41ColumnbladeHighSpeedConnectionTyperead-onlymandatoryConnection type of the high speed expansion card number 1.
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.51ColumnbladeIOCompatibilityread-onlymandatoryI/O compatibility status for the blade. The possible values and their meanings are as follows: unknown: This indicates a communication error for the blade. ok:…
1.3.6.1.4.1.2.3.51.2.22.1.5.1.1.52ColumnbladeInventoryReadyread-onlymandatoryWhen a blade management controller or the AMM is reset, the blade inventory data is refreshed in the AMM database. This includes items like IBM VPD (e.g. - ser…
1.3.6.1.4.1.2.3.51.2.22.1.5.2TablebladeHealthSummaryTablenot-accessiblemandatoryTable of blade health summary information. Contains information about the overall blade health status.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1RowbladeHealthSummaryEntrynot-accessiblemandatoryBlade health summary entry
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.1ColumnbladeHealthSummaryIndexread-onlymandatoryBlade health summary index.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.2ColumnbladeHealthSummaryBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.3ColumnbladeHealthSummarySeverityread-onlymandatorySystem health summary severity.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.4ColumnbladeHealthSummaryDescriptionread-onlymandatorySystem health summary description.
1.3.6.1.4.1.2.3.51.2.22.1.5.2.1.5ColumnbladeHealthSummaryDateTimeread-onlymandatorySystem health summary date time.
1.3.6.1.4.1.2.3.51.2.22.1.5.3TablebladeTemperaturesTablenot-accessiblemandatoryTable of blade temperatures information.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1RowbladeTemperaturesEntrynot-accessiblemandatoryBlade temperatures table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1ColumntemperatureIndexread-onlymandatoryBlade temperatures table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2ColumntemperatureBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3ColumntemperatureBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4ColumntemperatureBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5ColumntemperatureBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6ColumntemperatureCPU1read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7ColumntemperatureCPU2read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8ColumntemperatureCPU3read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9ColumntemperatureCPU4read-onlymandatoryThe blade CPU temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space for…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10ColumntemperatureDASD1read-onlymandatoryThe blade DASD temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank space fo…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11ColumnbladeSensorTempCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12ColumnbladeSensor1Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13ColumnbladeSensor2Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14ColumnbladeSensor3Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15ColumnbladeSensor4Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16ColumnbladeSensor5Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17ColumnbladeSensor6Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18ColumnbladeSensor7Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19ColumnbladeSensor8Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20ColumnbladeSensor9Tempread-onlymandatoryTemperature reading for an IPMI blade expressed in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4TablebladeTemperatureThresholdsTablenot-accessiblemandatoryTable of blade temperature thresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1RowbladeTemperatureThresholdsEntrynot-accessiblemandatoryBlade temperature thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1ColumntemperatureThresholdIndexread-onlymandatoryBlade temperature threshold table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2ColumntemperatureThresholdBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3ColumntemperatureThresholdBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4ColumntemperatureThresholdBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5ColumntemperatureThresholdBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6ColumntemperatureCPU1HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7ColumntemperatureCPU1Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8ColumntemperatureCPU1WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.9ColumntemperatureCPU2HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10ColumntemperatureCPU2Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11ColumntemperatureCPU2WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12ColumntemperatureCPU3HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13ColumntemperatureCPU3Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14ColumntemperatureCPU3WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15ColumntemperatureCPU4HardShutdownread-onlymandatoryThe blade CPU hard shutdown temperature in degrees centigrade(C). If the component's temperature rises above this value the system will be powered off immediat…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16ColumntemperatureCPU4Warningread-onlymandatoryThe blade CPU warning temperature in degrees centigrade(C). If the temperature rises above this value a warning alert/event if enabled will be generated. An oc…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17ColumntemperatureCPU4WarningResetread-onlymandatoryThe blade CPU warning reset temperature in degrees centigrade(C). If the temperature rises above this value and if a warning alert/event had previously been cr…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18ColumntemperatureDASD1HardShutdownread-onlymandatoryThe blade DASD hard shutdown temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or …
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19ColumntemperatureDASD1Warningread-onlymandatoryThe blade DASD warning temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or blank …
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20ColumntemperatureDASD1WarningResetread-onlymandatoryThe blade DASD warning reset temperature in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for negative or …
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21ColumnbladeTempThresholdSensorCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22ColumntemperatureSensor1HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23ColumntemperatureSensor1Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24ColumntemperatureSensor1WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25ColumntemperatureSensor2HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26ColumntemperatureSensor2Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27ColumntemperatureSensor2WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28ColumntemperatureSensor3HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29ColumntemperatureSensor3Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30ColumntemperatureSensor3WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31ColumntemperatureSensor4HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32ColumntemperatureSensor4Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33ColumntemperatureSensor4WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34ColumntemperatureSensor5HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35ColumntemperatureSensor5Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36ColumntemperatureSensor5WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37ColumntemperatureSensor6HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38ColumntemperatureSensor6Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39ColumntemperatureSensor6WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40ColumntemperatureSensor7HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41ColumntemperatureSensor7Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42ColumntemperatureSensor7WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43ColumntemperatureSensor8HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44ColumntemperatureSensor8Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45ColumntemperatureSensor8WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46ColumntemperatureSensor9HardShutdownread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47ColumntemperatureSensor9Warningread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48ColumntemperatureSensor9WarningResetread-onlymandatoryThe blade hard shutdown temperature for IPMI blades in degrees centigrade(C). An octet string expressed as 'sddd.dd Centigrade' where: s is the sign ('-' for n…
1.3.6.1.4.1.2.3.51.2.22.1.5.5TablebladeVoltagesTablenot-accessiblemandatoryTable of blade voltages information.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1RowbladeVoltagesEntrynot-accessiblemandatoryBlade voltages table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.1ColumnvoltageIndexread-onlymandatoryBlade voltages table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.2ColumnvoltageBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.3ColumnvoltageBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.4ColumnvoltageBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.5ColumnvoltageBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.6ColumnbladePlus5Voltread-onlymandatory+5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.7ColumnbladePlus3pt3Voltread-onlymandatory+3.3 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative …
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.8ColumnbladePlus12Voltread-onlymandatory+12 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative o…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.10ColumnbladePlus2pt5Voltread-onlymandatory+2.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative …
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.11ColumnbladePlus1pt5Voltread-onlymandatory+1.5 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative …
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.12ColumnbladePlus1pt25Voltread-onlymandatory+1.25 Volt power supply voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.13ColumnbladeVRM1Voltread-onlymandatoryVRM 1 voltage reading for the blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positi…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.14ColumnbladeSensorVoltCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.15ColumnbladeSensor1Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.16ColumnbladeSensor2Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.17ColumnbladeSensor3Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.18ColumnbladeSensor4Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.19ColumnbladeSensor5Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.20ColumnbladeSensor6Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.21ColumnbladeSensor7Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.22ColumnbladeSensor8Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.23ColumnbladeSensor9Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.24ColumnbladeSensor10Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.25ColumnbladeSensor11Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.26ColumnbladeSensor12Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.27ColumnbladeSensor13Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.28ColumnbladeSensor14Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.29ColumnbladeSensor15Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.30ColumnbladeSensor16Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.31ColumnbladeSensor17Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.32ColumnbladeSensor18Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.33ColumnbladeSensor19Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.34ColumnbladeSensor20Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.35ColumnbladeSensor21Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.36ColumnbladeSensor22Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.37ColumnbladeSensor23Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.38ColumnbladeSensor24Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.39ColumnbladeSensor25Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.40ColumnbladeSensor26Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.41ColumnbladeSensor27Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.42ColumnbladeSensor28Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.43ColumnbladeSensor29Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.5.1.44ColumnbladeSensor30Voltread-onlymandatoryVoltage reading for an IPMI blade expressed in Volts(V). An octet string expressed as 'sdd.dd Volts' where: s is the sign ('-' for negative or '+' for positive…
1.3.6.1.4.1.2.3.51.2.22.1.5.6TablebladeVoltageThresholdsTablenot-accessiblemandatoryTable of blade VoltageThresholds information.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1RowbladeVoltageThresholdsEntrynot-accessiblemandatoryBlade voltage thresholds table entry
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.1ColumnvoltageThresholdIndexread-onlymandatoryBlade voltage thresholds table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.2ColumnvoltageThresholdBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.3ColumnvoltageThresholdBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.4ColumnvoltageThresholdBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.5ColumnvoltageThresholdBladeNameread-writemandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.6ColumnbladePlus5VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.7ColumnbladePlus5VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.8ColumnbladePlus3pt3VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.9ColumnbladePlus3pt3VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.10ColumnbladePlus12VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.11ColumnbladePlus12VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.14ColumnbladePlus2pt5VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.15ColumnbladePlus2pt5VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.16ColumnbladePlus1pt5VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.17ColumnbladePlus1pt5VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.18ColumnbladePlus1pt25VoltHighWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage rises above this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.19ColumnbladePlus1pt25VoltLowWarningread-onlymandatoryVoltage warning threshold reading expressed in Volts(V). If the voltage drops below this value a warning alert/event if enabled will be generated. An octet str…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.22ColumnbladeVoltThresholdSensorCapabilityread-onlymandatoryIndicates whether the server blade is IPMI capable or not.
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.23ColumnbladeSensor1VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.24ColumnbladeSensor1VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.25ColumnbladeSensor2VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.26ColumnbladeSensor2VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.27ColumnbladeSensor3VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.28ColumnbladeSensor3VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.29ColumnbladeSensor4VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.30ColumnbladeSensor4VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.31ColumnbladeSensor5VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.32ColumnbladeSensor5VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.33ColumnbladeSensor6VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.34ColumnbladeSensor6VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.35ColumnbladeSensor7VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.36ColumnbladeSensor7VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.37ColumnbladeSensor8VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.38ColumnbladeSensor8VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.39ColumnbladeSensor9VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.40ColumnbladeSensor9VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.41ColumnbladeSensor10VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.42ColumnbladeSensor10VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.43ColumnbladeSensor11VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.44ColumnbladeSensor11VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.45ColumnbladeSensor12VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.46ColumnbladeSensor12VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.47ColumnbladeSensor13VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.48ColumnbladeSensor13VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.49ColumnbladeSensor14VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.50ColumnbladeSensor14VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.51ColumnbladeSensor15VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.52ColumnbladeSensor15VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.53ColumnbladeSensor16VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.54ColumnbladeSensor16VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.55ColumnbladeSensor17VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.56ColumnbladeSensor17VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.57ColumnbladeSensor18VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.58ColumnbladeSensor18VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.59ColumnbladeSensor19VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.60ColumnbladeSensor19VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.61ColumnbladeSensor20VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.62ColumnbladeSensor20VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.63ColumnbladeSensor21VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.64ColumnbladeSensor21VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.65ColumnbladeSensor22VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.66ColumnbladeSensor22VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.67ColumnbladeSensor23VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.68ColumnbladeSensor23VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.69ColumnbladeSensor24VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.70ColumnbladeSensor24VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.71ColumnbladeSensor25VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.72ColumnbladeSensor25VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.73ColumnbladeSensor26VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.74ColumnbladeSensor26VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.75ColumnbladeSensor27VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.76ColumnbladeSensor27VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.77ColumnbladeSensor28VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.78ColumnbladeSensor28VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.79ColumnbladeSensor29VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.80ColumnbladeSensor29VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.81ColumnbladeSensor30VoltHighWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage rises above this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.6.1.82ColumnbladeSensor30VoltLowWarningread-onlymandatoryVoltage warning threshold reading for IPMI blades expressed in Volts(V). If the voltage drops below this value, a critical alert/event if enabled will be gener…
1.3.6.1.4.1.2.3.51.2.22.1.5.7TablebladeIOCompatibilityTablenot-accessiblemandatoryTable of IO Compatibility status for the blade.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1RowbladeIOCompatibilityEntrynot-accessiblemandatoryBlade IO Compatibility Status entry
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.1ColumnbladeIOCompatibilityIndexread-onlymandatoryThe blade I/O compatibility table index.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.2ColumnbladeIOCompatibilityBladeIdread-onlymandatoryThe blade numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.3ColumnbladeIOCompatibilityBayNumberread-onlymandatoryThe Bay number of the blade or expension card.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.4ColumnbladeIOCompatibilityModuleBayread-onlymandatoryThe modules (each one specified by module type and bay number) that the blade can communicate with over the midplane networking fabric (i.e. a physical path ex…
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.5ColumnbladeIOCompatibilityModulePowerread-onlymandatoryThe power state of the module specified in bladeIOCompatibilityModuleBay. n/a if module not installed.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.6ColumnbladeIOCompatibilityModuleFabricTyperead-onlymandatoryThe fabric type of the module specified in bladeIOCompatibilityModuleBay.
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.7ColumnbladeIOCompatibilityFabricOnBladeread-onlymandatoryThe fabric type for this channel on the blade (may be onboard fabric or an expansion card).
1.3.6.1.4.1.2.3.51.2.22.1.5.7.1.8ColumnbladeIOCompatibilityStatusread-onlymandatoryThe compatibility status between the blade and the module specified in bladeIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues No I…
1.3.6.1.4.1.2.3.51.2.22.1.6NodebladePowerRestart
1.3.6.1.4.1.2.3.51.2.22.1.6.1TablebladePowerRestartTablenot-accessiblemandatoryTable of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1RowbladePowerRestartEntrynot-accessiblemandatoryBlade power restart table entry
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.1ColumnpowerRestartIndexread-onlymandatoryBlade power restart table index.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.2ColumnpowerRestartBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.3ColumnpowerRestartBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.4ColumnpowerRestartBladePowerStateread-onlymandatoryIndicates the power state of the blade specified. If the state cannot be determined, the unknown(255) value is returned.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.5ColumnpowerRestartBladeHealthStateread-onlymandatoryThe system health state for the blade. Unknown: Blade is in an undefined state. Good: Blade is operating normally. Warning: One or more outstanding warnings ex…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.6ColumnpowerRestartBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.7ColumnpowerOnOffBladeread-writemandatoryControl the power state of a specific blade. Off: Power Off Blade. On: Power On Blade. Softoff: Shut Down OS and Power Off Blade. This operation is not support…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.8ColumnrestartBladeread-writemandatoryRestart a blade. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.9ColumnrestartBladeSMPread-writemandatoryRestart a blade's system management processor. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.10ColumnrestartBladeNMIread-writemandatoryIssue an NMI to the blade. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.11ColumnrestartBladeClearNVRAMread-writemandatoryRestart a blade and set NVRAM to default values. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this M…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.12ColumnrestartBladeInvokeDiagsread-writemandatoryRestart a blade and boot into diagnostic mode. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB…
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.13ColumnrestartBladeInvokeDiagsFromDefaultBootListread-writemandatoryRestart a blade and boot into diagnostic mode from Default Boot List as defined on the blade. This option is not supported on all blades. NOTE: Value returned …
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.14ColumnrestartBladeToSMSBootMenuread-writemandatoryRestart a blade to SMS boot menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.6.1.1.15ColumnrestartBladeToUEFIMenuread-writemandatoryRestart a blade to UEFI setup menu. This option is not supported on all blades. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.1.7NodebladeConfiguration
1.3.6.1.4.1.2.3.51.2.22.1.7.1TablebladeConfigurationTablenot-accessiblemandatoryTable of blade remote power control information. Contains power on/off enablement status for each blade.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1RowbladeConfigurationEntrynot-accessiblemandatoryBlade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.1ColumnconfigurationIndexread-onlymandatoryBlade configuration table index.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.2ColumnconfigurationBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.3ColumnconfigurationBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.4ColumnconfigurationBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.5ColumnconfigurationBladeNameread-writemandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.6ColumnconfigurationBladecKVMread-writemandatoryEnable or disable the concurrent KVM function on specified blade. If concurrent KVM is not supported by the blade, it displays 'notPresent' and the concurrent …
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.7ColumnconfigurationBladeActiveBootModeread-onlymandatoryIndicates the active copy of the firmware from which the blade is booting. NOTE: Some blades do not support the automatic boot recovery. It displays 'notApplic…
1.3.6.1.4.1.2.3.51.2.22.1.7.1.1.8ColumnconfigurationBladePendingBootModeread-writemandatoryIndicates the copy of the firmware from which the blade will boot after the next reboot. NOTE: Some blades do not support the automatic boot recovery. It displ…
1.3.6.1.4.1.2.3.51.2.22.1.7.2NodebladePowerManagementPolicy
1.3.6.1.4.1.2.3.51.2.22.1.7.2.1Scalarpowerdomain1Oversubscriptionread-writemandatoryPower Management Policy settings for power domain 1.
1.3.6.1.4.1.2.3.51.2.22.1.7.2.2Scalarpowerdomain2Oversubscriptionread-writemandatoryPower Management Policy settings for power domain 2.
1.3.6.1.4.1.2.3.51.2.22.1.7.2.3ScalaracousticModeread-writemandatoryAcoustic mode setting for thermal conditions
1.3.6.1.4.1.2.3.51.2.22.1.7.2.4ScalarnebsModeread-writemandatoryNEBS (Network Equipment-Building System) mode setting for thermal conditions. NOTE: This MIB object is for BladeCenter T, HT and TR only.
1.3.6.1.4.1.2.3.51.2.22.1.7.3ScalarbladecKVMEnableDisableread-writemandatoryEnable or disable cKVM function on all server blades.
1.3.6.1.4.1.2.3.51.2.22.1.8ScalarbladeIPAddrRangeStartread-onlydeprecatedThis field is used to configure the start of the IP address range for the blade system management processors on the blades. These addresses are used on the int…
1.3.6.1.4.1.2.3.51.2.22.1.9NodebladeCapacityOnDemand
1.3.6.1.4.1.2.3.51.2.22.1.9.1TablebladeCapacityOnDemandTablenot-accessibledeprecatedTable of COD blade. NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1RowbladeCapacityOnDemandEntrynot-accessibledeprecatedBlade COD table entry NOTE: This table is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.1ColumnbladeCapacityOnDemandIndexread-onlydeprecatedBlade configuration table index. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.2ColumnbladeCapacityOnDemandBladeNameread-onlydeprecatedThe name of the blade as a null terminated string. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.9.1.1.3ColumnbladeCapacityOnDemandStateread-writedeprecatedThe state of Capacity On Demand. NOTE: This Mib object is deprecated and no longer supported.
1.3.6.1.4.1.2.3.51.2.22.1.10NodebladeBootCountPowerOnTime
1.3.6.1.4.1.2.3.51.2.22.1.10.1TablebladeBootCountPowerOnTimeTablenot-accessiblemandatoryTable per blade of the number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1RowbladeBootCountPowerOnTimeEntrynot-accessiblemandatoryThe number of boots for the blade and the number of seconds the blade has been powered on.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.1ColumnbootCountPowerOnTimeBladeIndexread-onlymandatoryBlade boot count/Power On Time table index.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.2ColumnbootCountPowerOnTimeBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.3ColumnbootCountPowerOnTimeBootsread-writemandatoryBlade Boot Count. If there is no blade in the given slot then this value is undefined. Writing this value resets the Boot Count to zero.
1.3.6.1.4.1.2.3.51.2.22.1.10.1.1.4ColumnbootCountPowerOnTimeSecsread-writemandatoryBlade Power On Time in seconds. If there is no blade in the given slot then this value is undefined. Writing this value resets the Power On Time to zero.
1.3.6.1.4.1.2.3.51.2.22.1.11ScalarbladeVlanIdread-writemandatoryThis is the virtual LAN ID for the internal management network between the MM and the blade system management processors (BSMPs). The range of valid VLAN ID's …
1.3.6.1.4.1.2.3.51.2.22.1.12NodebladeNetworkConfiguration
1.3.6.1.4.1.2.3.51.2.22.1.12.2TablebladeNetworkInterfaceTablenot-accessiblemandatoryTable of all blades' network interfaces.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1RowbladeNetworkInterfaceEntrynot-accessiblemandatoryBlade configuration table entry
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.1ColumnbladeNetworkInterfaceIndexread-onlymandatoryBlade Network Interface Table index.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.2ColumnbladeNetworkInterfaceBayNumberread-onlymandatoryThe bay number of the main server blade that supports network interface management
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.3ColumnbladeNetworkInterfaceNumberread-onlymandatoryIndicates which network interface on the blade System Management Processor is be read or writen
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.4ColumnbladeNetworkInterfaceTyperead-onlymandatoryIndicates blade network interface type.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.5ColumnbladeNetworkInterfaceLabelread-onlymandatoryShow string label that identifies the interface.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.6ColumnbladeNetworkInterfaceIPAddrread-writemandatoryShow/modify current IP address of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceD…
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.7ColumnbladeNetworkInterfaceSubnetMaskread-writemandatoryShow or modifie current subnet mask of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInter…
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.8ColumnbladeNetworkInterfaceGatewayAddrread-writemandatoryShow or modify current IP gateway of the blade network interface. Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfa…
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.9ColumnbladeNetworkInterfaceVlanIdread-writemandatoryThis is the Virtual LAN ID for supported network interface cards (NICs). The range of valid VLAN ID's is 0 to 4095.
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.10ColumnbladeNetworkInterfaceVlanEnableread-onlydeprecatedThis object is no longer supported and will always be 0
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.11ColumnbladeNetworkInterfaceEnableread-writemandatoryDisabled or enabled the blade network interface. If the network interface is disabled, then ignore other configurations. If this network interface doesn't supp…
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.12ColumnbladeNetworkInterfaceDHCPEnableread-writemandatoryIP config method on the blade network interface to modify mode to static IP, dhcp and dhcpthenstatic. If this network interface doesn't support DHCP, show 'not…
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.13ColumnbladeNetworkInterfaceMACAddrread-onlymandatoryShow the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'
1.3.6.1.4.1.2.3.51.2.22.1.12.2.1.14ColumnbladeNetworkInterfaceAssignedSwitchread-writemandatoryThis field allows you to select an I/O Module to use for management traffic to the blade. NOTE: This field is only supported for eth1 of blade. NOTE: You may o…
1.3.6.1.4.1.2.3.51.2.22.1.12.10NodebladeIPv6Config
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1TablebladeIPv6ConfigTablenot-accessiblemandatoryA table of IPv6 configuration options for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1RowbladeIPv6ConfigEntrynot-accessiblemandatoryIPv6 configuration options for a blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.1ColumnbladeIPv6ConfigIndexread-onlymandatoryThe blade's slot number
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.2ColumnbladeIPv6ConfigPortIndexread-onlymandatoryThe physical port number of the given entry
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.3ColumnbladeIPv6ConfigEnabledread-writemandatoryEnables/Disables IPv6 support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.4ColumnbladeIPv6ConfigStaticread-writemandatoryEnables/Disables IPv6 static configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.5ColumnbladeDHCPv6ConfigEnabledread-writemandatoryEnables/Disables DHCPv6 address configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.1.1.6ColumnbladeIPv6ConfigStatelessEnabledread-writemandatoryEnables/Disables IPv6 stateless auto-configuration support on the blade.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2TablebladeIPv6AddressTablenot-accessiblemandatoryA table of assigned IPv6 addresses for blades. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1RowbladeIPv6AddressEntrynot-accessiblemandatoryThe assigned IPv6 address for a given blade. NOTE: This MIB object is not applicable to blades that do not support IPv6.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.1ColumnbladeIPv6AddressIndexread-onlymandatoryThe blade's slot number.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.2ColumnbladeIPv6AddressPortIndexread-onlymandatoryThe blade's physical port number for the given entry.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.3ColumnbladeIPv6AddressEntryIndexread-onlymandatoryThe blade's address entry index.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.4ColumnbladeIPv6AddressTyperead-onlymandatoryThe address type.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.5ColumnbladeIPv6Addressread-writemandatoryThe assigned IPv6 address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.6ColumnbladeIPv6AddressPrefixLenread-writemandatoryThe prefix length for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.12.10.2.1.7ColumnbladeIPv6AddressDefaultRouteread-writemandatoryThe default route used for the given address. Note: 'write' is for static ipv6 only.
1.3.6.1.4.1.2.3.51.2.22.1.13TablebladeBayDataTablenot-accessiblemandatoryTable of blade bay data (BBD) information.
1.3.6.1.4.1.2.3.51.2.22.1.13.1RowbladeBayDataEntrynot-accessiblemandatoryBlade bay data (BBD) table entry.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.1ColumnbayDataIndexread-onlymandatoryBlade bay data (BBD) table index.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.2ColumnbayDataBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.3ColumnbayDataBladeExistsread-onlymandatoryIndicates whether the server blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.4ColumnbayDataBladePowerStateread-onlymandatoryIndicates the power state of the blade specified.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.5ColumnbayDataBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.13.1.6ColumnbayDataread-writemandatoryA null terminated string that defines the Blade Bay Data (BBD). This data is pushed to the blade's BSMP and SMBIOS structures, where it can used by the blade's…
1.3.6.1.4.1.2.3.51.2.22.1.13.1.7ColumnbayDataBladeStatusread-onlymandatoryThis shows Blade Bay Data (BBD) status. 0 means the blade fully supports BBD; 1 means that the blade's BIOS does not support BBD; 2 means that there is no blad…
1.3.6.1.4.1.2.3.51.2.22.1.14NodebladeSPEthOverUSBInterface
1.3.6.1.4.1.2.3.51.2.22.1.14.1TablespEthOverUSBInterfaceTablenot-accessiblemandatoryTable of blade Service Processor's Ethernet over USB interface.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1RowspEthOverUSBInterfaceEntrynot-accessiblemandatoryBlade Service Processor's Ethernet over USB interface entry.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.1ColumnspEthOverUSBInterfaceIndexread-onlymandatoryService Processor's Ethernet over USB interface table index.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.2ColumnspEthOverUSBInterfaceBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.3ColumnspEthOverUSBInterfaceBladeExistsread-onlymandatoryIndicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.6ColumnspEthOverUSBInterfaceBladeNameread-onlymandatoryThe name of the blade as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.1.14.1.1.9ColumnspEthOverUSBInterfaceEnableread-writemandatoryThis object allows the user to view the status of, and enable or disable, a blade Service Processor's command interface on Ethernet-over-USB. NOTE: If the blad…
1.3.6.1.4.1.2.3.51.2.22.1.15NodebladeManagementNetwork
1.3.6.1.4.1.2.3.51.2.22.1.15.1ScalarbladeManagementNetworkControlEnableread-writemandatoryGlobally disable/enable blade management network auto discovery support.
1.3.6.1.4.1.2.3.51.2.22.1.15.2TablebladeManagementNetworkInfoTablenot-accessiblemandatoryTable of blade management network information.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1RowbladeManagementNetworkInfoEntrynot-accessiblemandatoryBlade management network information entry.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.1ColumnbladeManagementNetworkInfoIndexread-onlymandatoryBlade management network information table index
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.2ColumnbladeManagementNetworkInfoBladeIdread-onlymandatoryThe Blade ID.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.3ColumnbladeManagementNetworkInfoBladeExistread-onlymandatoryIndicates whether the blade specified exists or not in the chassis.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.4ColumnbladeManagementNetworkInfoBladeSupportread-onlymandatoryIndicates whether the blade supports the management network auto discovery capability or not.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.5ColumnbladeManagementNetworkInfoPathStatusread-onlymandatoryIndicates the status of the management network for this blade.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.6ColumnbladeManagementNetworkInfoBladeIPAddrread-onlymandatoryIndicates the blade system management processor IPv4 address.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.7ColumnbladeManagementNetworkInfoBladeMACAddrread-onlymandatoryIndicates the blade system management processor MAC address.
1.3.6.1.4.1.2.3.51.2.22.1.15.2.1.8ColumnbladeManagementNetworkInfoSwitchIdread-onlymandatoryIndicates which switch is selected for the blade management network.
1.3.6.1.4.1.2.3.51.2.22.3NodeswitchModule
1.3.6.1.4.1.2.3.51.2.22.3.1NodeswitchModuleControl
1.3.6.1.4.1.2.3.51.2.22.3.1.1TablesmControlTablenot-accessiblemandatorySwitch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1RowsmControlEntrynot-accessiblemandatorySwitch module control table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.1ColumnsmControlIndexread-onlymandatorySwitch module control table index.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.2ColumnswitchModuleControlIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.3ColumnsmPostResultsAvailableread-onlymandatoryDescribes whether the switch module POST diagnostic result value contained in the smPostResultsValue is valid.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.4ColumnsmPostResultsValueread-onlymandatoryThe range of values and meanings are as follows: 0x00 - 0x7F ( 0 - 127) Base internal functions 0x80 - 0x9F (128 - 159) Internal interface failures 0xA0 - 0xAF…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.5ColumnswitchModuleMemDiagEnableDisableread-writemandatorySwitch module memory diagnostics enabled or disabled. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and …
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.6ColumnsmCfgCtrlEnableDisableread-writemandatorySwitch module configuration control. When set to enabled, only the MM can manage the module. This MIB object can not be set, if AMM grants switch module the Pr…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.7ColumnsmExtEthPortsEnableDisableread-writemandatorySwitch module external ethernet ports enabled or disabled. This MIB object can not be set, if AMM grants switch module the Protected Mode permission. This MIB …
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.8ColumnswitchPingRequestread-writedeprecatedSends a ping to a switch module's current IPv4 address. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch mo…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9ColumnsmCfgCtrlOnResetEnableDisableread-writemandatorySwitch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the …
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.15ColumnsmHealthStateread-onlymandatoryThe health state for the switch module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.16ColumnsmPMStateread-onlymandatoryThe Protected Mode Status for the switch module. standby- Protected Mode capability exists on the IOM but has not been activated on the switch module or the AM…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.17ColumnsmPMCtrlEnableDisableread-writemandatoryAMM Protected Mode permission for the switch module. disabled - allow AMM to disable Protected Mode Permission for the switch module. enabled - allow AMM to gr…
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.18ColumnsmIOCompatibilityread-onlymandatoryThe compatibility status for the I/O module. The possible values and their meanings are as follows: Unknown: This indicates a communication error for the I/O m…
1.3.6.1.4.1.2.3.51.2.22.3.1.2TablesmPingTablenot-accessiblemandatoryAllows pinging one of the active assigned addresses of an I/O module. NOTE: This table is not applicable to modules that are running in Stacking Mode and IP co…
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1RowsmPingEntrynot-accessiblemandatoryRepresents a single address that can be pinged
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.1ColumnsmPingIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.2ColumnsmPingAddressEntryIndexread-onlymandatoryThe switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.3ColumnsmPingAddressread-onlymandatoryThe switch module's IPv4 or IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.1.2.1.4ColumnsmPingAddressExecuteread-writemandatoryPings the given IP address. NOTE: The GET operation for this object is meaningless.
1.3.6.1.4.1.2.3.51.2.22.3.1.7TablesmPowerRestartTablenot-accessiblemandatorySwitch module power restart table.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1RowsmPowerRestartEntrynot-accessiblemandatorySwitch module power restart table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.1ColumnsmPowerRestartIndexread-onlymandatorySwitch module power restart index.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.2ColumnsmPowerRestartIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.3ColumnsmSwitchExistsread-onlymandatoryIndicates whether the switch module specified exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.4ColumnsmSwitchTyperead-onlymandatorySwitch module type.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.5ColumnsmMACAddressread-onlymandatorySwitch module MAC address.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.6ColumnsmIPAddressread-onlymandatoryThe switch module current IP address. If the switch module is participating in the Stacking Mode and IP Configuration is protected, then the stack management I…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.7ColumnswitchModulePowerOnOffread-writemandatoryI/O Module power on or power off. If powering on a currently powered off I/O Module, then the I/O Module will execute a POST. The results of this POST will nee…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.8ColumnsmResetread-writemandatoryFor the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause i…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.9ColumnsmResetToDefaultread-writemandatoryFor the case where the switch module is currently powered on, this command will effectively power off and then power on the switch module indicated and cause i…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.10ColumnsmRestartAndRunStdDiagread-writemandatoryTo power cycle the selected module(s) and then run the standard diagnostic test package. NOTE: Value returned for the GET command is meaningless for this MIB o…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.11ColumnsmRestartAndRunExtDiagread-writemandatoryTo power cycle the selected module(s) and then run the extended diagnostic test package. This option is not supported on all I/O modules. NOTE: Value returned …
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.12ColumnsmRestartAndRunFullDiagread-writemandatoryTo power cycle the selected module(s) and then run the full diagnostic test package. The full diagnostic test package may take over 5 minutes to run. This opti…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.20ColumnsmSwitchSubTyperead-onlymandatorySwitch module subtype. NOTE: Some Legacy modules do not support a subtype and will be displayed as unknown.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.21ColumnsmSwitchWidthread-onlymandatorySwitch module width.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.22ColumnsmManufacturingIDread-onlymandatorySwitch module hardware VPD manufacturing ID.
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.23ColumnsmStackingModeStateread-onlymandatoryThe Stacking Mode Status for the switch module. standby - I/O module has stacking capability but is not part of a stack. member - I/O module has stacking capab…
1.3.6.1.4.1.2.3.51.2.22.3.1.7.1.24ColumnsmStackingModeInforead-onlymandatoryA string containing a text description about the details of which functions are protected for a switch module when it is in Stacking Mode as Master or Member. …
1.3.6.1.4.1.2.3.51.2.22.3.1.10TablesmIOCompatibilityTablenot-accessiblemandatorySwitch module control table.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1RowsmIOCompatibilityEntrynot-accessiblemandatorySwitch module IO compatibility table entry
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.1ColumnsmIOCompatibilityIndexread-onlymandatorySwitch module IO compatibility index.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.2ColumnsmIOCompatibilityIdread-onlymandatoryThe switch module numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.3ColumnsmIOCompatibilityModuleBayread-onlymandatoryThe modules (each one specified by module type and bay number) that this I/O module can communicate with over the midplane networking fabric (i.e. a physical p…
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.4ColumnsmIOCompatibilityModulePowerread-onlymandatoryThe power state of the module specified in smIOCompatibilityModuleBay.
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.5ColumnsmIOCompatibilityModuleFabricTyperead-onlymandatoryThe I/O fabric type on the module side for the module. 'n/a' will be displayed if the corresponding channel is not populated on the module side (e.g. we are lo…
1.3.6.1.4.1.2.3.51.2.22.3.1.10.1.6ColumnsmIOCompatibilityStatusread-onlymandatoryThe compatibility status for this I/O module and the module specified in smIOCompatibilityModuleBay. The possible values are: OK: No compatibility issues n/a: …
1.3.6.1.4.1.2.3.51.2.22.3.2NodeswitchModuleConfig
1.3.6.1.4.1.2.3.51.2.22.3.2.1NodeswitchMgmtNetworkCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1NodeswitchCurrentNwCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1TablesmCurrentIPInfoTablenot-accessiblemandatorySwitch module current IP information. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1RowsmCurrentIPInfoEntrynot-accessiblemandatorySwitch module current IP table entry. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.1ColumnsmCurrentIPInfoIndexread-onlymandatorySwitch module current IP info index. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.2ColumnsmCurrentIPInfoIdread-onlymandatoryThe switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.3ColumnsmCurrentIPInfoExistsread-onlymandatoryIndicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP config…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.4ColumnsmCurrentIPInfoPowerStateread-onlymandatoryIndicates whether the I/O Module specified is powered on or not. The value 'shutdownInProgress' is for the I/O Module that may take some time to transition fro…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.6ColumnsmCurrentIPAddrread-onlymandatoryThe switch module current IP address. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.7ColumnsmCurrentSubnetMaskread-onlymandatoryThe switch module current subnet mask. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.8ColumnsmCurrentGatewayread-onlymandatoryThe switch module current IP gateway. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is protected.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.1.1.1.9ColumnsmCurrentIPConfigMethodread-onlymandatoryThe switch module current IP configuration method. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2NodeswitchNewNwCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1TablesmNewIPInfoTablenot-accessiblemandatorySwitch module new IP information. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mod…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1RowsmNewIPInfoEntrynot-accessiblemandatorySwitch module new IP configuration information table entry. NOTE: This MIB table is not applicable to modules that are running in Network Address Translation (…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.1ColumnsmNewIPInfoIndexread-onlymandatorySwitch module new IP info index. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking Mode…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.2ColumnsmNewIPInfoIdread-onlymandatoryThe switch module numeric identifier. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode or Stacking…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.3ColumnsmNewIPInfoExistsread-onlymandatoryIndicates whether the switch module specified exists or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.4ColumnsmNewIPInfoPowerStateread-onlymandatoryIndicates whether the switch module specified is powered on or not. NOTE: This MIB object is not applicable to modules that are running in Network Address Tran…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.6ColumnsmNewIPAddrread-writemandatoryThe switch module new IP address. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB ob…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.7ColumnsmNewSubnetMaskread-writemandatoryThe switch module new subnet mask. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB o…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.8ColumnsmNewGatewayread-writemandatoryThe switch module new IP gateway. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE: This MIB ob…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.9ColumnsmNewIPConfigMethodread-writemandatoryThe switch module new IP configuration method. Before setting this object to a new value, smNewIpconfigEnableDisable object must first be set to disabled. NOTE…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.2.1.1.10ColumnsmNewIPConfigEnableDisableread-writemandatoryA set command enables a new IP configuration that has been previously defined. A get command indicates whether the new IP configuration information has been en…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3NodeswitchNwProtCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1NodeswitchNwProtCfgModOne
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1TablesmNwProtInfoModOneTablenot-accessiblemandatorySwitch module 1 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1RowsmNwProtInfoModOneEntrynot-accessiblemandatorySwitch module 1 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.1ColumnsmNwProtInfoModOneIndexread-onlymandatorySwitch module 1 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.2ColumnsmNwProtInfoModOneIdread-onlymandatoryThe switch module 1 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.3ColumnsmNwProtInfoModOneExistsread-onlymandatoryIndicates whether the switch module 1 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.4ColumnsmNwProtInfoModOnePowerStateread-onlymandatoryIndicates whether the switch module 1 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.5ColumnsmNwProtInfoModOneProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.6ColumnsmNwProtInfoModOneProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.7ColumnsmNwProtInfoModOneExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.8ColumnsmNwProtInfoModOneIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.1.1.9ColumnsmNwProtInfoModOneEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.2ScalarsmNwProtInfoModOneActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.1.3ScalarsmNwProtInfoModOneResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2NodeswitchNwProtCfgModTwo
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1TablesmNwProtInfoModTwoTablenot-accessiblemandatorySwitch module 2 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1RowsmNwProtInfoModTwoEntrynot-accessiblemandatorySwitch module 2 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.1ColumnsmNwProtInfoModTwoIndexread-onlymandatorySwitch module 2 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.2ColumnsmNwProtInfoModTwoIdread-onlymandatoryThe switch module 2 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.3ColumnsmNwProtInfoModTwoExistsread-onlymandatoryIndicates whether the switch module 2 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.4ColumnsmNwProtInfoModTwoPowerStateread-onlymandatoryIndicates whether the switch module 2 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.5ColumnsmNwProtInfoModTwoProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.6ColumnsmNwProtInfoModTwoProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.7ColumnsmNwProtInfoModTwoExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.8ColumnsmNwProtInfoModTwoIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.1.1.9ColumnsmNwProtInfoModTwoEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.2ScalarsmNwProtInfoModTwoActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.2.3ScalarsmNwProtInfoModTwoResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3NodeswitchNwProtCfgModThree
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1TablesmNwProtInfoModThreeTablenot-accessiblemandatorySwitch module 3 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1RowsmNwProtInfoModThreeEntrynot-accessiblemandatorySwitch module 3 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.1ColumnsmNwProtInfoModThreeIndexread-onlymandatorySwitch module 3 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.2ColumnsmNwProtInfoModThreeIdread-onlymandatoryThe switch module 3 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.3ColumnsmNwProtInfoModThreeExistsread-onlymandatoryIndicates whether the switch module 3 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.4ColumnsmNwProtInfoModThreePowerStateread-onlymandatoryIndicates whether the switch module 3 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.5ColumnsmNwProtInfoModThreeProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.6ColumnsmNwProtInfoModThreeProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.7ColumnsmNwProtInfoModThreeExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.8ColumnsmNwProtInfoModThreeIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.1.1.9ColumnsmNwProtInfoModThreeEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.2ScalarsmNwProtInfoModThreeActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.3.3ScalarsmNwProtInfoModThreeResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4NodeswitchNwProtCfgModFour
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1TablesmNwProtInfoModFourTablenot-accessiblemandatorySwitch module 4 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1RowsmNwProtInfoModFourEntrynot-accessiblemandatorySwitch module 3 network protocol (Network Address Translation) configuration information table entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.1ColumnsmNwProtInfoModFourIndexread-onlymandatorySwitch module 4 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.2ColumnsmNwProtInfoModFourIdread-onlymandatoryThe switch module 4 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.3ColumnsmNwProtInfoModFourExistsread-onlymandatoryIndicates whether the switch module 4 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.4ColumnsmNwProtInfoModFourPowerStateread-onlymandatoryIndicates whether the switch module 4 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.5ColumnsmNwProtInfoModFourProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.6ColumnsmNwProtInfoModFourProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.7ColumnsmNwProtInfoModFourExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.8ColumnsmNwProtInfoModFourIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.1.1.9ColumnsmNwProtInfoModFourEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.2ScalarsmNwProtInfoModFourActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.4.3ScalarsmNwProtInfoModFourResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5NodeswitchNwProtCfgModFive
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1TablesmNwProtInfoModFiveTablenot-accessiblemandatorySwitch module 5 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1RowsmNwProtInfoModFiveEntrynot-accessiblemandatorySwitch module 5 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.1ColumnsmNwProtInfoModFiveIndexread-onlymandatorySwitch module 5 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.2ColumnsmNwProtInfoModFiveIdread-onlymandatoryThe switch module 5 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.3ColumnsmNwProtInfoModFiveExistsread-onlymandatoryIndicates whether the switch module 5 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.4ColumnsmNwProtInfoModFivePowerStateread-onlymandatoryIndicates whether the switch module 5 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.5ColumnsmNwProtInfoModFiveProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.6ColumnsmNwProtInfoModFiveProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.7ColumnsmNwProtInfoModFiveExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.8ColumnsmNwProtInfoModFiveIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.1.1.9ColumnsmNwProtInfoModFiveEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.2ScalarsmNwProtInfoModFiveActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.5.3ScalarsmNwProtInfoModFiveResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6NodeswitchNwProtCfgModSix
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1TablesmNwProtInfoModSixTablenot-accessiblemandatorySwitch module 6 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1RowsmNwProtInfoModSixEntrynot-accessiblemandatorySwitch module 6 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.1ColumnsmNwProtInfoModSixIndexread-onlymandatorySwitch module 6 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.2ColumnsmNwProtInfoModSixIdread-onlymandatoryThe switch module 6 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.3ColumnsmNwProtInfoModSixExistsread-onlymandatoryIndicates whether the switch module 6 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.4ColumnsmNwProtInfoModSixPowerStateread-onlymandatoryIndicates whether the switch module 6 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.5ColumnsmNwProtInfoModSixProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.6ColumnsmNwProtInfoModSixProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.7ColumnsmNwProtInfoModSixExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.8ColumnsmNwProtInfoModSixIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.1.1.9ColumnsmNwProtInfoModSixEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.2ScalarsmNwProtInfoModSixActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.6.3ScalarsmNwProtInfoModSixResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7NodeswitchNwProtCfgModSeven
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1TablesmNwProtInfoModSevenTablenot-accessiblemandatorySwitch module 7 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1RowsmNwProtInfoModSevenEntrynot-accessiblemandatorySwitch module 7 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.1ColumnsmNwProtInfoModSevenIndexread-onlymandatorySwitch module 7 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.2ColumnsmNwProtInfoModSevenIdread-onlymandatoryThe switch module 7 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.3ColumnsmNwProtInfoModSevenExistsread-onlymandatoryIndicates whether the switch module 7 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.4ColumnsmNwProtInfoModSevenPowerStateread-onlymandatoryIndicates whether the switch module 7 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.5ColumnsmNwProtInfoModSevenProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.6ColumnsmNwProtInfoModSevenProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.7ColumnsmNwProtInfoModSevenExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.8ColumnsmNwProtInfoModSevenIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.1.1.9ColumnsmNwProtInfoModSevenEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.2ScalarsmNwProtInfoModSevenActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.7.3ScalarsmNwProtInfoModSevenResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8NodeswitchNwProtCfgModEight
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1TablesmNwProtInfoModEightTablenot-accessiblemandatorySwitch module 8 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1RowsmNwProtInfoModEightEntrynot-accessiblemandatorySwitch module 8 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.1ColumnsmNwProtInfoModEightIndexread-onlymandatorySwitch module 8 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.2ColumnsmNwProtInfoModEightIdread-onlymandatoryThe switch module 8 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.3ColumnsmNwProtInfoModEightExistsread-onlymandatoryIndicates whether the switch module 8 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.4ColumnsmNwProtInfoModEightPowerStateread-onlymandatoryIndicates whether the switch module 8 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.5ColumnsmNwProtInfoModEightProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.6ColumnsmNwProtInfoModEightProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.7ColumnsmNwProtInfoModEightExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.8ColumnsmNwProtInfoModEightIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.1.1.9ColumnsmNwProtInfoModEightEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.2ScalarsmNwProtInfoModEightActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.8.3ScalarsmNwProtInfoModEightResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9NodeswitchNwProtCfgModNine
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1TablesmNwProtInfoModNineTablenot-accessiblemandatorySwitch module 9 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1RowsmNwProtInfoModNineEntrynot-accessiblemandatorySwitch module 9 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.1ColumnsmNwProtInfoModNineIndexread-onlymandatorySwitch module 9 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.2ColumnsmNwProtInfoModNineIdread-onlymandatoryThe switch module 9 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.3ColumnsmNwProtInfoModNineExistsread-onlymandatoryIndicates whether the switch module 9 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.4ColumnsmNwProtInfoModNinePowerStateread-onlymandatoryIndicates whether the switch module 9 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.5ColumnsmNwProtInfoModNineProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.6ColumnsmNwProtInfoModNineProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.7ColumnsmNwProtInfoModNineExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.8ColumnsmNwProtInfoModNineIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.1.1.9ColumnsmNwProtInfoModNineEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.2ScalarsmNwProtInfoModNineActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.9.3ScalarsmNwProtInfoModNineResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10NodeswitchNwProtCfgModTen
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1TablesmNwProtInfoModTenTablenot-accessiblemandatorySwitch module 10 network protocol (Network Address Translation) information.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1RowsmNwProtInfoModTenEntrynot-accessiblemandatorySwitch module 10 network protocol (Network Address Translation) configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.1ColumnsmNwProtInfoModTenIndexread-onlymandatorySwitch module 10 network protocol (Network Address Translation) information index.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.2ColumnsmNwProtInfoModTenIdread-onlymandatoryThe switch module 10 numeric identifier.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.3ColumnsmNwProtInfoModTenExistsread-onlymandatoryIndicates whether the switch module 10 exists or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.4ColumnsmNwProtInfoModTenPowerStateread-onlymandatoryIndicates whether the switch module 10 is powered on or not.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.5ColumnsmNwProtInfoModTenProtNameread-writemandatoryProtocol name
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.6ColumnsmNwProtInfoModTenProtIDread-writemandatoryProtocol ID
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.7ColumnsmNwProtInfoModTenExtPortread-writemandatoryExternal port
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.8ColumnsmNwProtInfoModTenIntPortread-writemandatoryInternal port.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.1.1.9ColumnsmNwProtInfoModTenEnableread-writemandatoryEnable or disable the protocol entry.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.2ScalarsmNwProtInfoModTenActivateread-writemandatoryActivate all network protocol settings for the switch module. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.3.10.3ScalarsmNwProtInfoModTenResetread-writemandatoryReset all network protocol settings for the switch module to default. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4NodeswitchIPv6Config
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1TablesmIPv6ConfigTablenot-accessiblemandatoryA table of IPv6 configuration options for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configura…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1RowsmIPv6ConfigEntrynot-accessiblemandatoryIPv6 configuration options for a switch module.. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration is p…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.1ColumnsmIPv6ConfigIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.2ColumnsmIPv6ConfigEnabledread-writemandatoryEnables/Disables IPv6 support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.3ColumnsmIPv6ConfigStaticread-writemandatoryEnables/Disables IPv6 static configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.4ColumnsmDHCPv6ConfigEnabledread-writemandatoryEnables/Disables DHCPv6 address configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.1.1.5ColumnsmIPv6ConfigStatelessEnabledread-writemandatoryEnables/Disables IPv6 stateless auto-configuration support on the switch module.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2TablesmIPv6AddressTablenot-accessiblemandatoryA table of assigned IPv6 addresses for switch modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuratio…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1RowsmIPv6AddressEntrynot-accessiblemandatoryThe assigned IPv6 address for a given switch module NOTE: This MIB object is not applicable to modules that are running in Stacking Mode and IP configuration i…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.1ColumnsmIPv6AddressIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.2ColumnsmIPv6AddressEntryIndexread-onlymandatoryThe switch module's address entry index
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.3ColumnsmIPv6AddressTyperead-onlymandatoryThe address type.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.4ColumnsmIPv6Addressread-onlymandatoryThe assigned IPv6 address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.5ColumnsmIPv6AddressPrefixLenread-onlymandatoryThe prefix length for the given address.
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.2.1.6ColumnsmIPv6AddressDefaultRouteread-onlymandatoryThe default route used for the given address
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3TablesmIPv6StaticConfigTablenot-accessiblemandatoryAllows configuration of static IPv6 information for supported IO modules. NOTE: This MIB object is not applicable to modules that are running in Stacking Mode …
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1RowsmIPv6StaticConfigEntrynot-accessiblemandatoryThe static IP address assignment information for an IO module. Once the assignement has taken place the address will show up as a row in the smIPv6AddressTable…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.1ColumnsmIPv6StaticIndexread-onlymandatoryThe switch module's slot number
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.2ColumnsmIPv6StaticAddressread-writemandatoryThe assigned IPv6 address. NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET comman…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.3ColumnsmIPv6StaticAddressPrefixLenread-writemandatoryThe prefix length for the given address. NOTE: If changing with smIPv6StaticAddress and/or smIPv6StaticAddressDefaultRoute sending the update as a single SET c…
1.3.6.1.4.1.2.3.51.2.22.3.2.1.4.3.1.4ColumnsmIPv6StaticAddressDefaultRouteread-writemandatoryThe default route used for the given address NOTE: If changing with smIPv6StaticAddressPrefixLen and/or smIPv6StaticAddress sending the update as a single SET …
1.3.6.1.4.1.2.3.51.2.22.3.2.2NodeswitchPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1NodeswitchModOnePortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1TablesmOnePortCfgTablenot-accessiblemandatorySwitch Module 1 port configuration information. NOTE: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1RowsmOnePortCfgEntrynot-accessiblemandatorySwitch Module 1 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.1ColumnsmOnePortCfgIndexread-onlymandatorySwitch Module 1 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.2ColumnsmOnePortCfgLabelread-onlymandatorySwitch Module 1 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.3ColumnsmOnePortCfgTyperead-onlymandatorySwitch Module 1 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.4ColumnsmOnePortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.5ColumnsmOnePortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.6ColumnsmOnePortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100 Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.7ColumnsmOnePortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.8ColumnsmOnePortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 1. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.9ColumnsmOnePortCfgMediaread-onlymandatoryPort media type of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.10ColumnsmOnePortCfgProtocolread-onlymandatoryPort protocol of Switch Module 1.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.11ColumnsmOnePortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 1. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.12ColumnsmOnePortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 1. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.13ColumnsmOnePortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.14ColumnsmOnePortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.15ColumnsmOnePortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.1.1.1.16ColumnsmOnePortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2NodeswitchModTwoPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1TablesmTwoPortCfgTablenot-accessiblemandatorySwitch Module 2 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1RowsmTwoPortCfgEntrynot-accessiblemandatorySwitch Module 2 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.1ColumnsmTwoPortCfgIndexread-onlymandatorySwitch Module 2 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.2ColumnsmTwoPortCfgLabelread-onlymandatorySwitch Module 2 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.3ColumnsmTwoPortCfgTyperead-onlymandatorySwitch Module 2 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.4ColumnsmTwoPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.5ColumnsmTwoPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.6ColumnsmTwoPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.7ColumnsmTwoPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.8ColumnsmTwoPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 2. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.9ColumnsmTwoPortCfgMediaread-onlymandatoryPort media type of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.10ColumnsmTwoPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 2.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.11ColumnsmTwoPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 2. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.12ColumnsmTwoPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 2. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.13ColumnsmTwoPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.14ColumnsmTwoPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.15ColumnsmTwoPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.2.1.1.16ColumnsmTwoPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3NodeswitchModThreePortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1TablesmThreePortCfgTablenot-accessiblemandatorySwitch Module 3 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1RowsmThreePortCfgEntrynot-accessiblemandatorySwitch Module 3 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.1ColumnsmThreePortCfgIndexread-onlymandatorySwitch Module 3 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.2ColumnsmThreePortCfgLabelread-onlymandatorySwitch Module 3 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.3ColumnsmThreePortCfgTyperead-onlymandatorySwitch Module 3 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.4ColumnsmThreePortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.5ColumnsmThreePortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.6ColumnsmThreePortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.7ColumnsmThreePortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.8ColumnsmThreePortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 3. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.9ColumnsmThreePortCfgMediaread-onlymandatoryPort media type of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.10ColumnsmThreePortCfgProtocolread-onlymandatoryPort protocol of Switch Module 3.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.11ColumnsmThreePortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 3. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.12ColumnsmThreePortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 3. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.13ColumnsmThreePortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.14ColumnsmThreePortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.15ColumnsmThreePortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.3.1.1.16ColumnsmThreePortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4NodeswitchModFourPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1TablesmFourPortCfgTablenot-accessiblemandatorySwitch Module 4 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1RowsmFourPortCfgEntrynot-accessiblemandatorySwitch Module 4 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.1ColumnsmFourPortCfgIndexread-onlymandatorySwitch Module 4 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.2ColumnsmFourPortCfgLabelread-onlymandatorySwitch Module 4 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.3ColumnsmFourPortCfgTyperead-onlymandatorySwitch Module 4 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.4ColumnsmFourPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.5ColumnsmFourPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.6ColumnsmFourPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.7ColumnsmFourPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.8ColumnsmFourPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 4. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.9ColumnsmFourPortCfgMediaread-onlymandatoryPort media type of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.10ColumnsmFourPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 4.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.11ColumnsmFourPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 4. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.12ColumnsmFourPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 4. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.13ColumnsmFourPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.14ColumnsmFourPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.15ColumnsmFourPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.4.1.1.16ColumnsmFourPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5NodeswitchModFivePortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1TablesmFivePortCfgTablenot-accessiblemandatorySwitch Module 5 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1RowsmFivePortCfgEntrynot-accessiblemandatorySwitch Module 5 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.1ColumnsmFivePortCfgIndexread-onlymandatorySwitch Module 5 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.2ColumnsmFivePortCfgLabelread-onlymandatorySwitch Module 5 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.3ColumnsmFivePortCfgTyperead-onlymandatorySwitch Module 5 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.4ColumnsmFivePortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.5ColumnsmFivePortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.6ColumnsmFivePortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.7ColumnsmFivePortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.8ColumnsmFivePortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 5. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.9ColumnsmFivePortCfgMediaread-onlymandatoryPort media type of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.10ColumnsmFivePortCfgProtocolread-onlymandatoryPort protocol of Switch Module 5.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.11ColumnsmFivePortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 5. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.12ColumnsmFivePortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 5. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.13ColumnsmFivePortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.14ColumnsmFivePortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.15ColumnsmFivePortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.5.1.1.16ColumnsmFivePortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6NodeswitchModSixPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1TablesmSixPortCfgTablenot-accessiblemandatorySwitch Module 6 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1RowsmSixPortCfgEntrynot-accessiblemandatorySwitch Module 6 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.1ColumnsmSixPortCfgIndexread-onlymandatorySwitch Module 6 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.2ColumnsmSixPortCfgLabelread-onlymandatorySwitch Module 6 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.3ColumnsmSixPortCfgTyperead-onlymandatorySwitch Module 6 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.4ColumnsmSixPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.5ColumnsmSixPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.6ColumnsmSixPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.7ColumnsmSixPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.8ColumnsmSixPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 6. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.9ColumnsmSixPortCfgMediaread-onlymandatoryPort media type of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.10ColumnsmSixPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 6.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.11ColumnsmSixPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 6. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.12ColumnsmSixPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 6. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.13ColumnsmSixPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.14ColumnsmSixPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.15ColumnsmSixPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.6.1.1.16ColumnsmSixPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7NodeswitchModSevenPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1TablesmSevenPortCfgTablenot-accessiblemandatorySwitch Module 7 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1RowsmSevenPortCfgEntrynot-accessiblemandatorySwitch Module 7 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.1ColumnsmSevenPortCfgIndexread-onlymandatorySwitch Module 7 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.2ColumnsmSevenPortCfgLabelread-onlymandatorySwitch Module 7 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.3ColumnsmSevenPortCfgTyperead-onlymandatorySwitch Module 7 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.4ColumnsmSevenPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.5ColumnsmSevenPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.6ColumnsmSevenPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.7ColumnsmSevenPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.8ColumnsmSevenPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 7. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.9ColumnsmSevenPortCfgMediaread-onlymandatoryPort media type of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.10ColumnsmSevenPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 7.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.11ColumnsmSevenPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 7. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.12ColumnsmSevenPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 7. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.13ColumnsmSevenPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.14ColumnsmSevenPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.15ColumnsmSevenPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.7.1.1.16ColumnsmSevenPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8NodeswitchModEightPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1TablesmEightPortCfgTablenot-accessiblemandatorySwitch Module 8 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1RowsmEightPortCfgEntrynot-accessiblemandatorySwitch Module 8 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.1ColumnsmEightPortCfgIndexread-onlymandatorySwitch Module 8 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.2ColumnsmEightPortCfgLabelread-onlymandatorySwitch Module 8 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.3ColumnsmEightPortCfgTyperead-onlymandatorySwitch Module 8 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.4ColumnsmEightPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.5ColumnsmEightPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.6ColumnsmEightPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.7ColumnsmEightPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.8ColumnsmEightPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 8. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.9ColumnsmEightPortCfgMediaread-onlymandatoryPort media type of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.10ColumnsmEightPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 8.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.11ColumnsmEightPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 8. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.12ColumnsmEightPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 8. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.13ColumnsmEightPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.14ColumnsmEightPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.15ColumnsmEightPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.8.1.1.16ColumnsmEightPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9NodeswitchModNinePortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1TablesmNinePortCfgTablenot-accessiblemandatorySwitch Module 9 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1RowsmNinePortCfgEntrynot-accessiblemandatorySwitch Module 9 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.1ColumnsmNinePortCfgIndexread-onlymandatorySwitch Module 9 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.2ColumnsmNinePortCfgLabelread-onlymandatorySwitch Module 9 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.3ColumnsmNinePortCfgTyperead-onlymandatorySwitch Module 9 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.4ColumnsmNinePortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.5ColumnsmNinePortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.6ColumnsmNinePortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.7ColumnsmNinePortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.8ColumnsmNinePortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 9. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.9ColumnsmNinePortCfgMediaread-onlymandatoryPort media type of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.10ColumnsmNinePortCfgProtocolread-onlymandatoryPort protocol of Switch Module 9.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.11ColumnsmNinePortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 9. A value of 0 indicates this field is not applicable to the switch p…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.12ColumnsmNinePortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 9. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.13ColumnsmNinePortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.14ColumnsmNinePortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.15ColumnsmNinePortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.9.1.1.16ColumnsmNinePortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10NodeswitchModTenPortCfg
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1TablesmTenPortCfgTablenot-accessiblemandatorySwitch Module 10 port configuration information. Note: This option is not supported on all I/O modules.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1RowsmTenPortCfgEntrynot-accessiblemandatorySwitch Module 10 port configuration information table entry
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.1ColumnsmTenPortCfgIndexread-onlymandatorySwitch Module 10 port sequence index.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.2ColumnsmTenPortCfgLabelread-onlymandatorySwitch Module 10 port label
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.3ColumnsmTenPortCfgTyperead-onlymandatorySwitch Module 10 port type: External port: This port is connected to external device and is for data traffic. External management port: This port is solely for…
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.4ColumnsmTenPortCfgLinkSettingread-writemandatoryCurrent port link setting for Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.5ColumnsmTenPortCfgLinkStateread-onlymandatoryCurrent port link state of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.6ColumnsmTenPortCfgSpeedSettingread-writemandatorySet the port speed using the data rate and duplex value. For examples: 100mf: 100Mbps in Half Duplex; 10gf: 10 Gbps in Full Duplex; auto: The working speed of …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.7ColumnsmTenPortCfgSpeedStatusread-onlymandatoryCurrent port speed of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.8ColumnsmTenPortCfgAvailSpeedsread-onlymandatoryAvailable speed setting per port for Switch Module 10. If there is more than one setting, the speeds are separated by a comma and then a space.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.9ColumnsmTenPortCfgMediaread-onlymandatoryPort media type of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.10ColumnsmTenPortCfgProtocolread-onlymandatoryPort protocol of Switch Module 10.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.11ColumnsmTenPortCfgWidthread-onlymandatoryThe width of the port in terms of how many combined cables are present for Switch Module 10. A value of 0 indicates this field is not applicable to the switch …
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.12ColumnsmTenPortCfgCableLengthread-onlymandatoryThe length (in meters) of the cable supported by this port for Switch Module 10. A value of 0 indicates this field is not applicable to the switch ports.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.13ColumnsmTenPortCfgCableTyperead-onlymandatoryExternal cable type for this port, for example, active copper or passive fiber.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.14ColumnsmTenPortCfgVendorNameread-onlymandatoryThe cable manufacturer.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.15ColumnsmTenPortCfgCompatibilityread-onlymandatoryCompatibility of the external cable that is plugged into the port.
1.3.6.1.4.1.2.3.51.2.22.3.2.2.10.1.1.16ColumnsmTenPortCfgDataRateread-onlymandatoryData rate supported for this port.
1.3.6.1.4.1.2.3.51.2.22.3.3NoderaidControllerConfig
1.3.6.1.4.1.2.3.51.2.22.3.3.1TableraidControllerTablenot-accessiblemandatoryRAID Controller control table.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1RowraidControllerEntrynot-accessiblemandatoryRAID Controller control table entry.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.1ColumnraidControllerIndexread-onlymandatoryRAID Controller control table index. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.2ColumnraidControllerIdread-onlymandatoryThe I/O Module numeric identifier for the SAS Controller Module. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.3ColumnraidControllerExistsread-onlymandatoryIndicates whether the I/O Module specified for the RAID Controller exists or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.4ColumnraidControllerPowerStateread-onlymandatoryIndicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.5ColumnraidControllerMACAddressread-onlymandatoryThe MAC address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.6ColumnraidControllerSasIDread-onlymandatoryThe hardware VPD SAS ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.1.1.7ColumnraidControllerPingRequestread-writemandatorySends a ping to the current IP address of the RAID Controller network interface. This MIB object can not be set, if AMM grants I/O Module the Protected Mode pe…
1.3.6.1.4.1.2.3.51.2.22.3.3.2NoderaidControllerNetworkCfg
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1TablercCurrentIPInfoTablenot-accessiblemandatoryRAID Controller current IP table. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1RowrcCurrentIPInfoEntrynot-accessiblemandatoryRAID Controller current IP table entry. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.1ColumnrcCurrentIPInfoIndexread-onlymandatoryRAID Controller current IP table index. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.2ColumnrcCurrentIPInfoIdread-onlymandatoryThe I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.3ColumnrcCurrentIPInfoExistsread-onlymandatoryIndicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.4ColumnrcCurrentIPInfoPowerStateread-onlymandatoryIndicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.5ColumnrcCurrentIPAddrread-onlymandatoryThe current IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.6ColumnrcCurrentSubnetMaskread-onlymandatoryThe current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.7ColumnrcCurrentGatewayread-onlymandatoryThe current subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.8ColumnrcCurrentIPConfigMethodread-onlymandatoryThe current IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.1.1.9ColumnrcCurrentRaidedVlanIdread-onlymandatoryThe current virtual LAN ID for the RAID Controller network interface. This MIB object is for SAS Controller Modules only.
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2TablercNewIPInfoTablenot-accessiblemandatoryRAID Controller new IP configuration table. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are run…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1RowrcNewIPInfoEntrynot-accessiblemandatoryRAID Controller new IP configuration information table entry. This MIB object is for SAS Controller Modules only. NOTE: This MIB table is not applicable to mod…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.1ColumnrcNewIPInfoIndexread-onlymandatoryRAID Controller new IP configuration information index. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules …
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.2ColumnrcNewIPInfoIdread-onlymandatoryThe I/O Module numeric identifier for the RAID Controller. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modul…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.3ColumnrcNewIPInfoExistsread-onlymandatoryIndicates whether the I/O Module exists or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules that are…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.4ColumnrcNewIPInfoPowerStateread-onlymandatoryIndicates whether the I/O Module is powered on or not. This MIB object is for SAS Controller Modules only. NOTE: This MIB object is not applicable to modules t…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.5ColumnrcNewIPAddrread-writemandatoryThe new IP address for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rc…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.6ColumnrcNewSubnetMaskread-writemandatoryThe new subnet mask for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, r…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.7ColumnrcNewGatewayread-writemandatoryThe new IP gateway for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a new value, rc…
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.8ColumnrcNewIPConfigMethodread-writemandatoryThe new IP configuration method for the RAID Controller network interface. This MIB object is for SAS Controller Modules only. Before setting this object to a …
1.3.6.1.4.1.2.3.51.2.22.3.3.2.2.1.11ColumnrcNewIPConfigEnableDisableread-writemandatoryA set command enables new IP configurations that have been defined. A get command indicates whether new IP configurations that have been enabled. NOTE: This MI…
1.3.6.1.4.1.2.3.51.2.22.4NodechassisTopology
1.3.6.1.4.1.2.3.51.2.22.4.1ScalarchassisResponseVersionread-onlymandatoryChassis response version.
1.3.6.1.4.1.2.3.51.2.22.4.2ScalarchassisFlagsread-onlymandatoryChassis flags. 1 = a server blade chassis, 0 = a rack or standalone chassis.
1.3.6.1.4.1.2.3.51.2.22.4.3ScalarchassisNameread-onlymandatoryThe name of the active MM as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.4.18ScalarchassisNoOfFPsSupportedread-onlymandatoryNumber of fan packs (FPs) supported. NOTE: Fan packs are also referred to as Power Module Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.19ScalarchassisNoOfPBsSupportedread-onlymandatoryNumber of processor blades (PBs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.20ScalarchassisNoOfSMsSupportedread-onlymandatoryNumber of switch modules (SMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.21ScalarchassisNoOfMMsSupportedread-onlymandatoryNumber of management modules (MMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.22ScalarchassisNoOfPMsSupportedread-onlymandatoryNumber of power modules (PMs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.23ScalarchassisNoOfMTsSupportedread-onlymandatoryNumber of media trays (MTs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.24ScalarchassisNoOfBlowersSupportedread-onlymandatoryNumber of blowers supported. NOTE: Blowers are also referred to as Chassis Cooling Devices.
1.3.6.1.4.1.2.3.51.2.22.4.25ScalarchassisPBsInstalledread-onlymandatoryThe blades that are installed on the chassis. The blades are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as the…
1.3.6.1.4.1.2.3.51.2.22.4.29ScalarchassisSMsInstalledread-onlymandatoryThe switch modules that are installed on the chassis. The switch modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that i…
1.3.6.1.4.1.2.3.51.2.22.4.30ScalarchassisMMsInstalledread-onlymandatoryThe management modules that are installed on the chassis. The management modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0'…
1.3.6.1.4.1.2.3.51.2.22.4.31ScalarchassisPMsInstalledread-onlymandatoryThe power modules that are installed on the chassis. The power modules are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is …
1.3.6.1.4.1.2.3.51.2.22.4.32ScalarchassisMTInstalledread-onlymandatoryIndicates whether at least one media tray (MT) is installed.
1.3.6.1.4.1.2.3.51.2.22.4.33ScalarchassisBlowersInstalledread-onlymandatoryThe blowers that are installed on the chassis. The blowers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long as t…
1.3.6.1.4.1.2.3.51.2.22.4.34ScalarchassisActiveMMread-onlymandatoryThe active management module (MM).
1.3.6.1.4.1.2.3.51.2.22.4.35ScalarchassisKVMOwnerread-onlymandatoryThe blade that currently owns the keyboard/video/monitor (KVM). 0 = the KVM devices are owned by the management module.
1.3.6.1.4.1.2.3.51.2.22.4.36ScalarchassisMediaTrayOwnerread-onlymandatoryThe blade that currently owns the media tray. 0 = the media tray is owned by the management module.
1.3.6.1.4.1.2.3.51.2.22.4.37ScalarchassisFPsInstalledread-onlymandatoryThe fan packs that are installed on the chassis. The fan packs are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as long …
1.3.6.1.4.1.2.3.51.2.22.4.38ScalarchassisTyperead-onlymandatoryThe type of the chassis. The BladeCenterS chassis and BladeCenterE are part of the bladeCenterOrBladeCenterH type. This MIB object should be used in conjunctio…
1.3.6.1.4.1.2.3.51.2.22.4.39ScalarchassisSubtyperead-onlymandatoryThe subtype of the chassis. This MIB object should be used in conjunction with chassisType MIB object to determine the characteristic of the chassis.
1.3.6.1.4.1.2.3.51.2.22.4.40ScalarchassisNoOfFBsSupportedread-onlymandatoryNumber of Front Bezel (FBs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.41ScalarchassisNoOfAPsSupportedread-onlymandatoryNumber of Alarm Panel (APs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.42ScalarchassisNoOfNCsSupportedread-onlydeprecatedNumber of Network Clocks (NCs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.43ScalarchassisNoOfMXsSupportedread-onlymandatoryNumber of Multiplexer Expansion modules (MXs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.44ScalarchassisNoOfMMIsSupportedread-onlymandatoryNumber of management module interposers (MMIs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.45ScalarchassisNoOfSMIsSupportedread-onlymandatoryNumber of switch module interposers (SMIs) supported.
1.3.6.1.4.1.2.3.51.2.22.4.46ScalarchassisNoOfFBsInstalledread-onlymandatoryThe return value of '1'indicates the front bezel is installed on the chassis. The value of '0' indicates the front bezel is not installed.
1.3.6.1.4.1.2.3.51.2.22.4.47ScalarchassisNoOfAPsInstalledread-onlymandatoryThe return value of '1'indicates the alarm panel is installed on the chassis. The value of '0' indicates the alarm panel is not installed.
1.3.6.1.4.1.2.3.51.2.22.4.48ScalarchassisNoOfNCsInstalledread-onlydeprecatedThe network clock cards that are installed on the chassis. The network clock cards are listed as a bitmap. The bitmap is a string containing a list of 1's and …
1.3.6.1.4.1.2.3.51.2.22.4.49ScalarchassisNoOfMXsInstalledread-onlymandatoryThe Multiplexer Expansion Modules that are installed on the chassis. The Multiplexer Expansion Modules are listed as a bitmap. The bitmap is a string containin…
1.3.6.1.4.1.2.3.51.2.22.4.50ScalarchassisNoOfMMIsInstalledread-onlymandatoryThe flex cables that are installed on the chassis. The flex cables are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as l…
1.3.6.1.4.1.2.3.51.2.22.4.51ScalarchassisNoOfSMIsInstalledread-onlymandatoryThe interposers that are installed on the chassis. The interposers are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as l…
1.3.6.1.4.1.2.3.51.2.22.4.52ScalarchassisNoOfMTsInstalledread-onlymandatoryThe media trays that are installed on the chassis. The media trays are listed as a bitmap. The bitmap is a string containing a list of 1's and 0's that is as l…
1.3.6.1.4.1.2.3.51.2.22.5NodemanagementModule
1.3.6.1.4.1.2.3.51.2.22.5.1TablemmStatusTablenot-accessiblemandatoryTable of the management module status. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.5.1.1RowmmStatusEntrynot-accessiblemandatoryManagement module status entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.1ColumnmmStatusIndexread-onlymandatoryManagement module status index.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.2ColumnmmPresentread-onlymandatoryManagement module current status.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.3ColumnmmExtIpAddressread-onlymandatoryManagement module external IP address. NOTE: The IPv6 addresses assigned to the AMM may be viewed with the extEthernetInterfaceIPv6 objects
1.3.6.1.4.1.2.3.51.2.22.5.1.1.4ColumnmmPrimaryread-onlymandatoryIndicates if this Management module is a primary or not. NOTE: If there is no standby MM, this value defaults to primary.
1.3.6.1.4.1.2.3.51.2.22.5.1.1.5ColumnmmHealthStateread-onlymandatoryThe health state for the management module. 0 = unknown, 1 = good, 2 = warning, 3 = bad.
1.3.6.1.4.1.2.3.51.2.22.6Nodestorage
1.3.6.1.4.1.2.3.51.2.22.6.1NodestorageStatus
1.3.6.1.4.1.2.3.51.2.22.6.1.1TablestorageStatusTablenot-accessiblemandatoryTable of the storage module status. For consistent results, view as a table and not as individual entries. NOTE: This MIB object is for BCS only.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1RowstorageStatusEntrynot-accessiblemandatoryStorage Module Status Table Entry.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.1ColumnstorageStatusIndexread-onlymandatoryStorage device status table index.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.2ColumnstorageBayNumberread-onlymandatoryBay number of the Storage device.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.3ColumnstorageStateread-onlymandatoryStorage device state.
1.3.6.1.4.1.2.3.51.2.22.6.1.1.1.4ColumnstorageNameread-onlymandatoryThe name of the storage device.
1.3.6.1.4.1.2.3.51.2.22.6.2NodestorageConfiguration
1.3.6.1.4.1.2.3.51.2.22.6.2.1NodestorageSwitchConfiguration
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1TablestorageSwitchZoneCfgTablenot-accessiblemandatoryTable of all the zone configurations stored on switch modules. For consistent results, view as a table and not as individual entries. Before activating a new z…
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1RowstorageSwitchZoneCfgEntrynot-accessiblemandatorySwitch Module Zone Configuration Management Entry.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.1ColumnswitchZoneCfgIndexread-onlymandatorySwitch module zone configuration table index.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.2ColumnswitchZoneCfgBayNumberread-onlymandatoryThe numeric switch bay number.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.3ColumnswitchZoneCfgNumberread-onlymandatoryThe zone configuration number, also referred to as the configuration store number.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.4ColumnswitchZoneCfgStatusread-onlymandatoryThe status of the zone configuration. Only one configuration is 'Active', others are in 'nonActive' status. When a zone configuration is active on a switch, th…
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.5ColumnswitchZoneCfgTyperead-onlymandatoryThe type of the zone configuration. Predefined are read-only static configurations, and userdefined are read-write configurations that can be created and modif…
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.6ColumnswitchZoneCfgNameread-onlymandatoryA short descriptive name for the zone configuration.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.7ColumnswitchZoneCfgDescriptionread-onlymandatoryA detailed description for the zone configuration.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.8ColumnswitchZoneCfgDateread-onlymandatoryThe date the zone configuration was created.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.1.1.9ColumnswitchActiveZoneCfgread-writemandatoryAn object used to activate a particular zone configuration. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2TablestorageSwitchActiveZoneCfgTablenot-accessiblemandatoryTable showing the zone configuration that is currently active on a given switch module. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1RowstorageSwitchActiveZoneCfgEntrynot-accessiblemandatoryActive zone configurations Entry.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.1ColumnactiveZoneCfgIndexread-onlymandatoryActive zone configurations table index.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.2ColumnactiveZoneCfgBayNumberread-onlymandatoryBay number of the switch module where active zone configurations exist.
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.3ColumnactiveZoneCfgNumberBySwitchread-onlymandatoryThe zone configuration number active on this SAS switch module as reported by the switch module. If this number differs from the value of the activeZoneCfgNumb…
1.3.6.1.4.1.2.3.51.2.22.6.2.1.2.1.4ColumnactiveZoneCfgNumberByMMread-onlymandatoryThe zone configuration number active on this SAS switch module as known by the management module. If this number differs from the value of the activeZoneCfgNum…
1.3.6.1.4.1.2.3.51.2.22.6.2.1.3ScalarswitchZoneCfgActivationread-writemandatoryThis object provides a quick means of activating a valid zone configuration on all active SAS switches. The zone configuration to be activated is specified as …
1.3.6.1.4.1.2.3.51.2.22.8NodefirmwareInformation
1.3.6.1.4.1.2.3.51.2.22.8.1NodesmFirmwareInformation
1.3.6.1.4.1.2.3.51.2.22.8.1.1TablesmFirmwareInfoTablenot-accessiblemandatorySwitch Module firmware image information. This table is only applicable to modules that support multiple images
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1RowsmFirmwareInfoEntrynot-accessiblemandatorySwitch Module firmware image information table entry
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.1ColumnsmFirmwareInfoIndexread-onlymandatorySequence index in the firmware table.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.2ColumnsmFirmwareInfoModIndexread-onlymandatorySwitch Module number.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.3ColumnsmFirmwareInfoImageIndexread-onlymandatorySwitch Module firmware image index.
1.3.6.1.4.1.2.3.51.2.22.8.1.1.1.4ColumnsmFirmwareInfoImageNameread-writemandatorySwitch Module firmware image name
1.3.6.1.4.1.2.3.51.2.22.9NodefirmwareUpdate
1.3.6.1.4.1.2.3.51.2.22.9.1ScalarfirmwareUpdateTargetread-writemandatoryTarget module whose firmware will be updated. NOTE: Some switch modules do not allow firmware update. When firmware update is attempted on those switch modules…
1.3.6.1.4.1.2.3.51.2.22.9.2ScalarfirmwareUpdateTftpServerread-writemandatoryIf flashing via the legacy method using a tftp server, then set the IP address or host name of the TFTP server where the firmware file resides. The address mus…
1.3.6.1.4.1.2.3.51.2.22.9.3ScalarfirmwareUpdateFileNameread-writemandatoryFile name of the firmware file.
1.3.6.1.4.1.2.3.51.2.22.9.4ScalarfirmwareUpdateStartread-writemandatoryStart updating the firmware of the specified target module. Using execute or execute-with-reboot will cause the SNMP client to wait for the firmware update to …
1.3.6.1.4.1.2.3.51.2.22.9.5ScalarfirmwareUpdateStatusread-onlymandatoryGet the status of the last firmware update which was initiated through SNMP method.
1.3.6.1.4.1.2.3.51.2.22.9.6ScalarstandbyFirmwareUpdateStatusread-onlymandatoryGet the current status of the firmware update for the standby AMM. NOTE: This only applies to systems with a standby AMM.
1.3.6.1.4.1.2.3.51.2.22.9.7ScalarfirmwareImageNumberread-writemandatoryIf the module can upload more than one image, an image number must be specified after setting the firmware target. Please refer to the firmwareInformation sect…
1.3.6.1.4.1.2.3.51.2.22.9.8ScalarfirmwareActiveImageread-writemandatoryIf the module can upload more than one image, an active image number must be specified. Please refer to the firmwareInformation section. NOTE: Value returned f…
1.3.6.1.4.1.2.3.51.2.22.9.9ScalarfirmwareUpdateServerread-writemandatoryContains the fully qualified remote location of the firmware packet file. Use firmwareUpdateFileName to specify the filename. A fully qualified remote location…
1.3.6.1.4.1.2.3.51.2.22.10NoderemoteChassis
1.3.6.1.4.1.2.3.51.2.22.10.1TableremoteChassisTablenot-accessiblemandatoryTable of remote chassis information.
1.3.6.1.4.1.2.3.51.2.22.10.1.1RowremoteChassisEntrynot-accessiblemandatoryRemote chassis entry
1.3.6.1.4.1.2.3.51.2.22.10.1.1.1ColumnremoteChassisIndexread-onlymandatoryRemote chassis discovery sequence index.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.2ColumnsystemNameread-onlymandatorySystem name for this discovery management module.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.3ColumnsystemStatusread-onlymandatorySystem status summary (chassis).
1.3.6.1.4.1.2.3.51.2.22.10.1.1.4ColumnmmTyperead-onlymandatoryService processor type.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.5ColumnmmSerialread-onlymandatoryManagement module serial number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.6ColumnmmFruread-onlymandatoryManagement module Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.7ColumnmmIpread-writemandatoryThe IPv4 compliant address of the management module.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.8ColumnchassisSerialread-onlymandatoryChassis serial number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.9ColumnchassisFruread-onlymandatoryChassis Field-Replaceable number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.10ColumnchassisMachineTypeModeread-onlymandatoryChassis machine type and model number.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.11ColumnchassisUuidread-onlymandatoryChassis unique identifier.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.12ColumnfirmwareVersionread-onlymandatoryFirmware version of the discovery management module.
1.3.6.1.4.1.2.3.51.2.22.10.1.1.13ColumnipStatusread-onlymandatoryA flag to state if IPv4 and IPv6 are enabled
1.3.6.1.4.1.2.3.51.2.22.10.1.1.14Columnipv6Addressesread-onlymandatoryThe IPv6 addresses configured for the chassis.
1.3.6.1.4.1.2.3.51.2.22.10.2ScalarchassisDiscoveryread-writemandatoryDiscovery of remote Chassis. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.2.22.11NodefileManagement
1.3.6.1.4.1.2.3.51.2.22.11.1NodefileTopology
1.3.6.1.4.1.2.3.51.2.22.11.1.1ScalarcurrentDirectoryread-writemandatorySpecifies the directory name for listing the requested files.
1.3.6.1.4.1.2.3.51.2.22.11.1.2TablefileDetailsTablenot-accessiblemandatoryA table of all the files in the specified directory. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1RowfileDetailsEntrynot-accessiblemandatoryFile details entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.1ColumnfileIndexread-onlymandatoryFile sequence index.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.2ColumnfileNameread-onlymandatoryFile name.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.3ColumnfileLastUpdateread-onlymandatoryDate of the latest file update.
1.3.6.1.4.1.2.3.51.2.22.11.1.2.1.4ColumnfileSizeread-onlymandatoryFile size in bytes.
1.3.6.1.4.1.2.3.51.2.22.11.3ScalarfileManagementCmdread-writemandatoryThis field will execute the selected operations on the files. The following operation is supported: DEL name - delete a file Examples: - to delete the file nam…
1.3.6.1.4.1.2.3.51.2.22.11.6ScalarfileSystemSpaceAvailableread-onlymandatoryThis field displays the available space of the AMM file system.
1.3.6.1.4.1.2.3.51.2.22.37NodecomponentMonitors
1.3.6.1.4.1.2.3.51.2.22.37.11TablecomponentMACAddressTablenot-accessiblemandatoryTable of MAC address VPD information for each component.
1.3.6.1.4.1.2.3.51.2.22.37.11.1RowcomponentMACAddressEntrynot-accessiblemandatoryComponent MAC address table entry
1.3.6.1.4.1.2.3.51.2.22.37.11.1.1ColumncomponentMACAddressTopologyPathread-onlymandatoryThe unique identifier for a component in this table. The chassis and each installed component is represented by a hardware topology tree, where each node in th…
1.3.6.1.4.1.2.3.51.2.22.37.11.1.2ColumncomponentMACAddressIndexread-onlymandatoryEach component may have one or more MAC address VPD values associated with it, and this index object identifies the particular instance.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.3ColumncomponentMACAddressNameread-onlymandatoryThe name of the component as a null terminated string.
1.3.6.1.4.1.2.3.51.2.22.37.11.1.4ColumncomponentMACAddressread-onlymandatoryThe MAC address VPD value for this component and index. The value is a null terminated string.
1.3.6.1.4.1.2.3.51.2.23Nodeservice
1.3.6.1.4.1.2.3.51.2.23.1NodeserviceConfig
1.3.6.1.4.1.2.3.51.2.23.1.3ScalardebugEnableread-writedeprecatedDisable/Enable AMM debugging with USB key by service personnel.
1.3.6.1.4.1.2.3.51.2.23.3NodebladeServiceData
1.3.6.1.4.1.2.3.51.2.23.3.1TablebladeServiceDataTablenot-accessiblemandatoryTable of blade service data information.
1.3.6.1.4.1.2.3.51.2.23.3.1.1RowbladeServiceDataEntrynot-accessiblemandatoryBlade service data entry
1.3.6.1.4.1.2.3.51.2.23.3.1.1.1ColumnserviceDataIndexread-onlymandatoryBlade service date index.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.2ColumnserviceDataBladeIdread-onlymandatoryThe numeric blade ID.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.3ColumnserviceDataBladeExistsread-onlymandatoryIndicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.4ColumnserviceDataBladePowerStateread-onlymandatoryIndicates whether the blade specified is powered on or not. If the AMM is experiencing a communication problem with the blade, the state may be returned as unk…
1.3.6.1.4.1.2.3.51.2.23.3.1.1.5ColumnserviceDataBladeNameread-onlymandatoryThe name of the blade as a string.
1.3.6.1.4.1.2.3.51.2.23.3.1.1.6ColumnserviceDataBladeCapabilityread-onlydeprecatedIndicates whether the blade has the capability to trigger service data. NOTE: This Mib object is deprecated and no longer supported. Please see serviceDataBlad…
1.3.6.1.4.1.2.3.51.2.23.3.1.1.7ColumnserviceDataDumpInitiateread-writemandatoryInitiates a type of dump collection to be initiated for the blade. NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask OID to see if …
1.3.6.1.4.1.2.3.51.2.23.3.1.1.8ColumnserviceDataDumpRetrieveread-writemandatoryRetrieve a type of service data file from blade to AMM. NOTE: This OID only is valid for the last four bit mask designations listed in the serviceDataDumpCapab…
1.3.6.1.4.1.2.3.51.2.23.3.1.1.9ColumnserviceDataDumpCapabilityMaskread-onlymandatoryIndicates whether the blade has the capability to trigger service data and if so, which operations are supported and whether the file can be transferred to the…
1.3.6.1.4.1.2.3.51.2.23.3.1.1.10ColumnserviceDataDumpInProgressread-onlymandatoryAn indicator as to whether a blade dump is in progress for the specified blade. This object ONLY applies to dumps that can be triggered by the AMM and where th…
1.3.6.1.4.1.2.3.51.2.23.3.3NodebladeSystemReferenceCodes
1.3.6.1.4.1.2.3.51.2.23.3.3.1TablebladeSysRefCodesTablenot-accessiblemandatoryTable of blade system reference codes.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1RowbladeSysRefCodesEntrynot-accessiblemandatoryBoot sequence entry
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.1ColumnsysRefCodeIndexread-onlymandatorySystem reference codes index.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.2ColumnsysRefCodeBayNumberread-onlymandatoryThe bay number of the blade which has the system reference code.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.3ColumnsysRefCodeSequenceread-onlymandatoryIndicates whether the blade specified exists or not.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.4ColumnsysRefCoderead-writemandatoryUnique ID and system reference code for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.1.1.5ColumnsysRefCodeTimestampread-writemandatoryTimestamp of system reference code for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.2TablebladeSysRefCodesDetailsTablenot-accessiblemandatoryTable of details of blade system reference codes.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1RowbladeSysRefCodesDetailsEntrynot-accessiblemandatoryBoot sequence entry
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.1ColumnsysRefCodeDetailIndexread-onlymandatorySystem reference codes index.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.2ColumnsysRefCodeDetailBayNumberread-onlymandatoryThe bay number of the blade which has the details of system reference code.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.3ColumnsysRefCodeDetailSRCSequenceread-onlymandatoryA sequence of the system reference codes for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.4ColumnsysRefCodeDetailSequenceread-writemandatoryA sequence of the detailed information of the system reference codes for the blade.
1.3.6.1.4.1.2.3.51.2.23.3.3.2.1.5ColumnsysRefCodeDetailDataStringread-writemandatoryDetailed information of the system reference codes for the blade.
1.3.6.1.4.1.2.3.51.2.23.4NodeserviceAdvisor
1.3.6.1.4.1.2.3.51.2.23.4.1NodeautoCallHomeSetup
1.3.6.1.4.1.2.3.51.2.23.4.1.1ScalaracceptLicenseAgreementread-writemandatoryAccept Terms and Conditions of AMM Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to IB…
1.3.6.1.4.1.2.3.51.2.23.4.1.2ScalarserviceAdvisorEnableread-writemandatoryDisable/Enable IBM Support. The User Agreement must be accepted and the contact information must be set before the IBM Support function of Service Advisor can …
1.3.6.1.4.1.2.3.51.2.23.4.2NodeserviceSupportCenter
1.3.6.1.4.1.2.3.51.2.23.4.2.1ScalaribmSupportCenterread-writemandatoryThe country code for the IBM Support Center. 2 character ISO country code.
1.3.6.1.4.1.2.3.51.2.23.4.3NodecontactInformation
1.3.6.1.4.1.2.3.51.2.23.4.3.1ScalarcompanyNameread-writemandatoryThe organization/company name of the contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.2ScalarcontactNameread-writemandatoryThe name of the contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.3ScalarphoneNumberread-writemandatoryThe phone of the contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.4ScalaremailAddressread-writemandatoryThe email of the contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphanumeric characters, '.…
1.3.6.1.4.1.2.3.51.2.23.4.3.5Scalaraddressread-writemandatoryThe address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. …
1.3.6.1.4.1.2.3.51.2.23.4.3.6Scalarcityread-writemandatoryThe city of the machine location. 1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.7Scalarstateread-writemandatoryThe state of the machine location. 2-3 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.8ScalarpostalCoderead-writemandatoryThe postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid.
1.3.6.1.4.1.2.3.51.2.23.4.3.10ScalarphoneNumberExtread-writemandatoryThe extension of the phone. 30 characters maximum.
1.3.6.1.4.1.2.3.51.2.23.4.3.11ScalaraltContactNameread-writemandatory(Optional) The name of the alternate contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.12ScalaraltPhoneNumberread-writemandatory(Optional) The phone of the alternate contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.3.13ScalaraltPhoneNumberExtread-writemandatory(Optional) The extension of the alternate phone. 30 characters maximum.
1.3.6.1.4.1.2.3.51.2.23.4.3.14ScalaraltEmailAddressread-writemandatory(Optional) The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum). The userid can be alphan…
1.3.6.1.4.1.2.3.51.2.23.4.3.15ScalarmachineLocPhoneread-writemandatory(Optional) The contact phone number of the machine location. 5-30 characters.
1.3.6.1.4.1.2.3.51.2.23.4.4NodehttpProxyConfig
1.3.6.1.4.1.2.3.51.2.23.4.4.1ScalarhttpProxyEnableread-writemandatoryDisable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the AMM to IBM. HTTP Proxy is used by the AMM when it is not co…
1.3.6.1.4.1.2.3.51.2.23.4.4.2ScalarhttpProxyLocationread-writemandatoryFully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters.
1.3.6.1.4.1.2.3.51.2.23.4.4.3ScalarhttpProxyPortread-writemandatoryThe port number of the HTTP Proxy. An integer value from 1 to 65535.
1.3.6.1.4.1.2.3.51.2.23.4.4.4ScalarhttpProxyUserNameread-writemandatoryUser Name of the HTTP Proxy. A maximum of 30 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.4.5ScalarhttpProxyPasswordread-writemandatoryPassword of the HTTP Proxy. A maximum of 15 characters string without spaces.
1.3.6.1.4.1.2.3.51.2.23.4.5NodeactivityLogs
1.3.6.1.4.1.2.3.51.2.23.4.5.1TableactivityLogTablenot-accessiblemandatoryTable of Service Advisor Activity Log entries information. This table displays the last five events that were generated by the system or user that are called h…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1RowactivityLogEntrynot-accessiblemandatoryActivity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by IBM support, the event ID, event sou…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.1ColumnactivityLogIndexread-onlymandatoryThe Activity Log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.2ColumnactivityLogStringread-onlymandatoryA string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and no…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.3ColumnactivityLogAcknowledgeread-writemandatoryThe acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of…
1.3.6.1.4.1.2.3.51.2.23.4.5.1.1.4ColumnactivityLogAttributeread-onlymandatoryA string of data detailing one Activity Log entry's attribute. It contains states of both calling IBM support and FTP/TFTP Server. A PENDING indicates that the…
1.3.6.1.4.1.2.3.51.2.23.5NodeautoFTPSetup
1.3.6.1.4.1.2.3.51.2.23.5.1ScalarautoFTPCallModeread-writemandatoryThis field specifies the automated problem reporting mode. Automated problem reporting mode allows the AMM to automatically put service data to a specified ser…
1.3.6.1.4.1.2.3.51.2.23.5.2ScalarautoFTPCallAddrread-writemandatoryThis field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address.
1.3.6.1.4.1.2.3.51.2.23.5.3ScalarautoFTPCallPortread-writemandatoryThis field specifies the port on remote FTP/TFTP server for data transmission.
1.3.6.1.4.1.2.3.51.2.23.5.4ScalarautoFTPCallUserIDread-writemandatoryThis field specifies the user account to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.5.5ScalarautoFTPCallPasswordread-writemandatoryThis field specifies the password to login remote FTP server.
1.3.6.1.4.1.2.3.51.2.23.6NodecallHomeExclusionEvents
1.3.6.1.4.1.2.3.51.2.23.6.1TablereadCallHomeExclusionEventTablenot-accessiblemandatoryTable of Call Home Exclusion Event entries information.
1.3.6.1.4.1.2.3.51.2.23.6.1.1RowreadCallHomeExclusionEventEntrynot-accessiblemandatoryCall Home Exclusion Event table entry
1.3.6.1.4.1.2.3.51.2.23.6.1.1.1ColumnreadCallHomeExclusionEventIndexread-onlymandatoryThe index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.1.1.2ColumnreadCallHomeExclusionEventIDread-onlymandatoryThe Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.2.23.6.2ScalaraddCallHomeExclusionEventread-writemandatoryAdd one call home Event ID into the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. If S…
1.3.6.1.4.1.2.3.51.2.23.6.3ScalarrmCallHomeExclusionEventread-writemandatoryRemove one call home Event ID from the Call Home Exclusion List. The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. I…
1.3.6.1.4.1.2.3.51.2.23.6.4ScalarrmAllCallHomeExclusionEventread-writemandatoryRemove all Event IDs from the Call Home Exclusion List. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE…
1.3.6.1.4.1.2.3.51.2.24Nodescaling
1.3.6.1.4.1.2.3.51.2.24.1TablescalableComplexTablenot-accessiblemandatoryTable of scalable complex information. This table provides information and control actions related to the scalable complexes installed in the chassis. Partitio…
1.3.6.1.4.1.2.3.51.2.24.1.1RowscalableComplexEntrynot-accessiblemandatoryScalable complex information.
1.3.6.1.4.1.2.3.51.2.24.1.1.1ColumnscalableComplexIdentifierread-onlymandatoryThe unique numeric identifier for a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.1.1.2ColumnscalableComplexNumPartitionsread-onlymandatoryThe number of partitions currently defined for this complex.
1.3.6.1.4.1.2.3.51.2.24.1.1.3ColumnscalableComplexNumNodesread-onlymandatoryThe number of nodes existing in this complex, regardless of their assignment to any given partition. The physical slot location of the nodes can be determined …
1.3.6.1.4.1.2.3.51.2.24.1.1.4ColumnscalableComplexPartStartSlotread-writemandatoryThe lowest slot number occupied by the nodes in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set…
1.3.6.1.4.1.2.3.51.2.24.1.1.5ColumnscalableComplexPartNumNodesread-writemandatoryThe number of nodes to be included in the new partition that is being created via the scalableComplexAction=create(3) action. This object must be set prior to …
1.3.6.1.4.1.2.3.51.2.24.1.1.6ColumnscalableComplexActionwrite-onlymandatoryThis object allows various actions to be taken in relation to a particular complex. clear(1) - This clears all partition information related to the complex. An…
1.3.6.1.4.1.2.3.51.2.24.2TablescalableComplexPartitionTablenot-accessiblemandatoryTable of scalable complex partition information. This table provides information and control actions related to the partitions defined across all of the comple…
1.3.6.1.4.1.2.3.51.2.24.2.1RowscalableComplexPartitionEntrynot-accessiblemandatoryScalable complex partition information.
1.3.6.1.4.1.2.3.51.2.24.2.1.1ColumnscalableComplexIdread-onlymandatoryThe unique numeric identifier for a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.2.1.2ColumnscalableComplexPartitionIdentifierread-onlymandatoryThe unique numeric identifier for a partition defined within a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.2.24.2.1.3ColumnscalableComplexPartitionModeread-writemandatoryThe currently configured mode of this partition. It is recommended that a partition be powered off prior to modification of the mode. In addition, switching a …
1.3.6.1.4.1.2.3.51.2.24.2.1.4ColumnscalableComplexPartitionNumNodesread-onlymandatoryThe number of nodes currently defined for this partition.
1.3.6.1.4.1.2.3.51.2.24.2.1.5ColumnscalableComplexPartitionStatusread-onlymandatoryThe current power status of this partition when the partition has a valid partition configuration. However, in the event the partition reports a partition cons…
1.3.6.1.4.1.2.3.51.2.24.2.1.6ColumnscalableComplexPartitionActionwrite-onlymandatoryThis object allows various actions to be taken in relation to a particular partition in a given complex. delete(1) - Deletes the partition from the complex. Al…
1.3.6.1.4.1.2.3.51.2.24.3TablescalableComplexNodeTablenot-accessiblemandatoryTable of scalable complex node information. This table provides information and control actions related to the nodes installed in the chassis. Complex, partiti…
1.3.6.1.4.1.2.3.51.2.24.3.1RowscalableComplexNodeEntrynot-accessiblemandatoryScalable complex node information.
1.3.6.1.4.1.2.3.51.2.24.3.1.1ColumnscalableComplexNodeSlotread-onlymandatoryThe base slot number where the node exists in the chassis.
1.3.6.1.4.1.2.3.51.2.24.3.1.2ColumnscalableComplexNodeNameread-onlymandatoryThe description string which uniquely identifies the blade.
1.3.6.1.4.1.2.3.51.2.24.3.1.3ColumnscalableComplexNodeTyperead-onlymandatoryThe general categorization of the node.
1.3.6.1.4.1.2.3.51.2.24.3.1.4ColumnscalableComplexNodeResourcesread-onlymandatoryA string providing a summary overview of the resources provided by this node.
1.3.6.1.4.1.2.3.51.2.24.3.1.5ColumnscalableComplexNodeRoleread-onlymandatoryIndicates if the node is assigned to a partition, and if so, provides an indication of whether the node is the primary node of the partition or not.
1.3.6.1.4.1.2.3.51.2.24.3.1.6ColumnscalableComplexNodeStateread-onlymandatoryThe physical power state of this node.
1.3.6.1.4.1.2.3.51.2.24.3.1.7ColumnscalableComplexNodeUUIDread-onlymandatoryThe Universally Unique IDentifier (UUID) of this node, represented as a 16 byte hex number.
1.3.6.1.4.1.2.3.51.2.24.3.1.8ColumnscalableComplexNodeSerialNumread-onlymandatoryThe serial number of this node.
1.3.6.1.4.1.2.3.51.2.24.3.1.9ColumnscalableComplexNodeNumPortsread-onlymandatoryThe number of remote nodes that this node has links to.
1.3.6.1.4.1.2.3.51.2.24.3.1.10ColumnscalableComplexNodeComplexIDread-onlymandatoryFor an assigned node, the identifier of the complex this node is related to. For an unassigned node, this object has no meaning.
1.3.6.1.4.1.2.3.51.2.24.3.1.11ColumnscalableComplexNodePartitionIDread-onlymandatoryFor an assigned node, the identifier of the partition this node is related to. For an unassigned node, this object has no meaning.
1.3.6.1.4.1.2.3.51.2.24.3.1.12ColumnscalableComplexNodeLogicalIDread-onlymandatoryThe unique numeric identifier for this node, unique within the partition.
1.3.6.1.4.1.2.3.51.2.24.3.1.14ColumnscalableComplexNodeActionwrite-onlymandatoryThe actions that can be applied to an unassigned node. The current state is provided by the scalableComplexNodeState object.
1.3.6.1.4.1.2.3.51.2.24.4TablescalableComplexNodePortTablenot-accessiblemandatoryTable of scalable complex node port information which provides details related to the port connectivity. Complex, partition and node information and control ar…
1.3.6.1.4.1.2.3.51.2.24.4.1RowscalableComplexNodePortEntrynot-accessiblemandatoryScalable complex node port information.
1.3.6.1.4.1.2.3.51.2.24.4.1.1ColumnscalableComplexNodePortSlotread-onlymandatoryThe base slot number where the node exists in the chassis.
1.3.6.1.4.1.2.3.51.2.24.4.1.2ColumnscalableComplexNodePortNumread-onlymandatoryThe port number of a port on this node. Note that this port number is 0-based, but since it is used as the table index (0 is not allowed), it will be presented…
1.3.6.1.4.1.2.3.51.2.24.4.1.3ColumnscalableComplexNodePortRemChkSumread-onlymandatoryThe checksum of the remote port, used as a port identifier.
1.3.6.1.4.1.2.3.51.2.24.4.1.4ColumnscalableComplexNodePortRemNumread-onlymandatoryThe zero-based port number of the remote port.
1.3.6.1.4.1.2.3.51.2.24.4.1.5ColumnscalableComplexNodePortStatusread-onlymandatoryThe current status of the port.
1.3.6.1.4.1.2.3.51.2.24.4.1.6ColumnscalableComplexNodePortTyperead-onlymandatoryThe port type.
Type Definitions
NameSyntaxStatusDescription
InetAddressIPv6OCTET STRING (SIZE (16)) EntryStatus ::= INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) }currentRepresents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET o…