MIB Viewer

BLADESPPALT-MIB

89 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212-- -- IMPORTS -- OBJECT-TYPE
RFC-1215-- TRAP-TYPE
RFC1155-SMI-- enterprises
RFC1213-MIB-- DisplayString
SNMPv2-SMI-- Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.6NodeibmProd
1.3.6.1.4.1.2.6.158NodesupportProcessor
1.3.6.1.4.1.2.6.158.3NodemmRemoteSupTrapMIB
1.3.6.1.4.1.2.6.158.3.0NodemmTrapTempCCritical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.1NodemmTrapVoltCCritical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.1NoderemoteSupTrapMibObjects
1.3.6.1.4.1.2.6.158.3.1.1NodespTrapInfo
1.3.6.1.4.1.2.6.158.3.1.1.1ScalarspTrapDateTimeread-onlymandatoryTimestamp of Local Date and Time when alert was generated NOTE: the format is changeable by a setting on the Management Module (Flex System only)
1.3.6.1.4.1.2.6.158.3.1.1.2ScalarspTrapAppIdread-onlymandatoryPlatform ID, either 'IBM Flex Chassis Management Module' (Flex System) or 'BladeCenter Management Module' (BladeCenter)
1.3.6.1.4.1.2.6.158.3.1.1.3ScalarspTrapSpTxtIdread-onlymandatorySP System Identification - Text Identification
1.3.6.1.4.1.2.6.158.3.1.1.4ScalarspTrapSysUuidread-onlymandatoryHost System UUID(Universal Unique ID)
1.3.6.1.4.1.2.6.158.3.1.1.5ScalarspTrapSysSernread-onlymandatory'Chassis Serial Number'(Flex System) or 'AMM Serial Number' (BladeCenter)
1.3.6.1.4.1.2.6.158.3.1.1.6ScalarspTrapAppTyperead-onlymandatoryApplication Alert Type - Trap Type ID
1.3.6.1.4.1.2.6.158.3.1.1.7ScalarspTrapPriorityread-onlymandatoryAlert Severity Value - Critical Alert(0) - Major(1) - Non-Critical Alert(2) - System Alert(4) - Recovery Alert(8) - Informational Only Alert(255)
1.3.6.1.4.1.2.6.158.3.1.1.8ScalarspTrapMsgTextread-onlymandatoryAlert Message Text
1.3.6.1.4.1.2.6.158.3.1.1.9ScalarspTrapHostContactread-onlymandatoryHost Contact
1.3.6.1.4.1.2.6.158.3.1.1.10ScalarspTrapHostLocationread-onlymandatoryHost Location
1.3.6.1.4.1.2.6.158.3.1.1.11ScalarspTrapBladeNameread-onlymandatoryServer Name NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.12ScalarspTrapBladeSernread-onlymandatoryServer Serial Number NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.13ScalarspTrapBladeUuidread-onlymandatoryServer UUID(Universal Unique ID) NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.14ScalarspTrapEvtNameread-onlymandatoryThe event ID in decimal (hexidecimal format may be cross referenced in InfoCenter).
1.3.6.1.4.1.2.6.158.3.1.1.15ScalarspTrapSourceIdread-onlymandatoryThe source identifier associated with the event that caused the trap - SERVPROC : event associated with the service processor - Audit : audit event (in audit l…
1.3.6.1.4.1.2.6.158.3.1.1.16ScalarspTrapCallHomeFlagread-onlymandatoryThe call home flag associated with the event that caused the trap - No Call Home generated with this event (0) - Call Home generated with this event if call ho…
1.3.6.1.4.1.2.6.158.3.1.1.17ScalarspTrapSysIPAddressread-onlymandatoryThe chassis Management Module IP Address. NOTE: In some very rare cases, the IP address will indicate 0.0.0.0 instead of the proper configured IP address. This…
1.3.6.1.4.1.2.6.158.3.1.1.18ScalarspTrapSysMachineModelread-onlymandatoryChassis Machine Type/Model
1.3.6.1.4.1.2.6.158.3.1.1.19ScalarspTrapBladeMachineModelread-onlymandatoryServer Machine Type/Model NOTE: This will only be populated if a server event triggered this trap.
1.3.6.1.4.1.2.6.158.3.1.1.20ScalarspTrapBladeFRUSerialNumberread-onlymandatoryServer Field Replaceable Unit (FRU) Serial Number NOTE: This will only be populated if a server event triggered this trap. spTrapBladeFRUSerialNumber is only a…
1.3.6.1.4.1.2.6.158.3.1.1.21ScalarspTrapBladeEvtNameread-onlymandatoryThe server event ID. This ID can be cross referenced in the InfoCenter. NOTE: This will only be populated if a server event triggered this trap. spTrapBladeEvt…
1.3.6.1.4.1.2.6.158.3.1.1.22ScalarspBladeEventDataSourceread-onlymandatoryThe 5 bytes are values from the IPMI standard SEL (System Event Log) entry received for from server. Byte 1 (SEL Byte 11) - IPMI Standard Sensor Type Byte 2 (S…
1.3.6.1.4.1.2.6.158.3.1.1.23ScalarspTrapAuxDataread-onlymandatoryAuxiliary data associated with the event. Truncated if more than 127 characters. NOTE: spTrapAuxData is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.24ScalarspTrapComponentIDread-onlymandatoryComponent ID to associate the trap with the location in the chassis and, if applicable, the node enclosure. NOTE: spTrapComponentID is only available on Flex S…
1.3.6.1.4.1.2.6.158.3.1.1.25ScalarspTrapComponentFRUInforead-onlymandatoryField Replaceable Unit (FRU) of the component that caused the trap. NOTE: spTrapComponentFRUInfo is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.26ScalarspTrapChassisNameread-onlymandatoryChassis Name NOTE: This will only populate if the Chassis Name has been set. spTrapChassisName is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.27ScalarspTrapSysRoomIdread-onlymandatoryChassis Room ID NOTE: This will only populate if the Chassis Room ID has been set. spTrapSysRoomId is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.28ScalarspTrapSysRackIdread-onlymandatoryChassis Rack ID NOTE: This will only populate if the Chassis Rack ID has been set. spTrapSysRackId is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.29ScalarspTrapSysRackUread-onlymandatoryChassis anchor (lowest) Rack U location NOTE: This will only populate if the Chassis lowest Rack U has been set (otherwise it will be '0'). spTrapSysRackU is o…
1.3.6.1.4.1.2.6.158.3.1.1.30ScalarspTrapServiceableEventFlagread-onlymandatoryThe serviceable event flag associated with the event that caused the trap - the event requires no user action (0) - the event is serviceable and requires user …
1.3.6.1.4.1.2.6.158.3.1.1.31ScalarspLogSequenceNumread-onlymandatorySequence number from the chassis event log or audit log. NOTE: Audit logs are stored separately internally. spLogSequenceNum is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.32ScalarspCimMsgIDread-onlymandatoryCIM Indication Message ID NOTE: spCimMsgID is only available on Flex System.
1.3.6.1.4.1.2.6.158.3.1.1.33ScalarspCimMsgPrefixread-onlymandatoryCIM Indication Message ID name space, one of the following: - PLAT : DMTF platform registry - CMM : CMM message registry NOTE: spCimMsgPrefix is only available…
1.3.6.1.4.1.2.6.158.3.1.1.34ScalarspEventCorrelatorread-onlymandatoryFor events originated by the CMM: If this event is part of a event group, this will be the unique identifier from 1 - 255 for the event group. Zero means no gr…
1.3.6.1.4.1.2.6.158.3.2NodemmTrapTampCCritical Alert: Physical intrusion of system has occurred. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.3NodemmTrapMffCCritical Alert: Multiple fan failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.4NodemmTrapPsCCritical Alert: Power supply failure.
1.3.6.1.4.1.2.6.158.3.5NodemTrapHdCCritical Alert: Hard disk drive failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.6NodemmTrapVrmCCritical Alert: Voltage Regulator Module(VRM) failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.7NodemmTrapLogFullNNon-Critical Alert: Event Log 100% Full.
1.3.6.1.4.1.2.6.158.3.10NodemmTrapRdpsNNon-Critical Alert: Redundant Power Supply failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.11NodemmTrapSffCCritical Alert: Single Fan failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.12NodemmTrapTempNNon-Critical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.13NodemmTrapVoltNNon-Critical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.15NodemmTrapSecDvSSystem Alert: Secondary Device warning. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.20NodemmTrapPostToSSystem Alert: Post Timeout value exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.21NodemmTrapOsToSSystem Alert: OS Timeout value exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.22NodemmTrapAppSSystem Alert: Application Alert.
1.3.6.1.4.1.2.6.158.3.23NodemmTrapPoffSSystem Alert: Power Off. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.24NodemmTrapPonSSystem Alert: Power On. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.25NodemmTrapBootSSystem Alert: System Boot Failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.26NodemmTrapLdrToSSystem Alert: OS Loader Timeout. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.27NodemmTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.30NodemmTrapRemoteLoginSSystem Alert: Remote Login
1.3.6.1.4.1.2.6.158.3.31NodemmTrapMsCCritical Alert: Multiple switch module failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.32NodemmTrapRmNNon-Critical Alert: Redundant module. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.33NodemmTrapKVMSwitchSSystem Alert: Keyboard/Video/Mouse(KVM) or Medial Tray(MT) switching failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.34NodemmTrapSysInvSSystem Alert: Inventory.
1.3.6.1.4.1.2.6.158.3.35NodemmTrapSysLogSSystem Alert: System Log 75% full.
1.3.6.1.4.1.2.6.158.3.36NodemmTrapIhcCCritical Alert: Incompatible hardware configuration. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.37NodemmTrapNwChangeSSystem Alert: Network change notification.
1.3.6.1.4.1.2.6.158.3.39NodemmTrapBlThrSSystem Alert: Blade Throttle. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.40NodemmTrapPwrMgntSSystem Alert: Power Management. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.128NodemmTrapBladeCCritical Alert: Blade.
1.3.6.1.4.1.2.6.158.3.129NodemmTrapIOCCritical Alert: I/O Module.
1.3.6.1.4.1.2.6.158.3.130NodemmTrapChassisCCritical Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.131NodemmTrapStorageCCritical Alert: Storage Module.
1.3.6.1.4.1.2.6.158.3.133NodemmTrapFanCCritical Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.160NodemmTrapBladeNNon-Critical Alert: Blade
1.3.6.1.4.1.2.6.158.3.161NodemmTrapIONNon-Critical Alert: I/O Module
1.3.6.1.4.1.2.6.158.3.162NodemmTrapChassisNNon-Critical Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.163NodemmTrapStorageNNon-Critical Alert: Storage Module
1.3.6.1.4.1.2.6.158.3.164NodemmTrapPowerNNon-Critical Alert: Power Module.
1.3.6.1.4.1.2.6.158.3.165NodemmTrapFanNNon-Critical Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.176NodemmTrapBladeSSystem Alert: Blade
1.3.6.1.4.1.2.6.158.3.177NodemmTrapIOSSystem Alert: I/O Module
1.3.6.1.4.1.2.6.158.3.178NodemmTrapChassisSSystem Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.179NodemmTrapStorageSSystem Alert: Storage Module
1.3.6.1.4.1.2.6.158.3.180NodemmTrapPowerSSystem Alert: Power Module.
1.3.6.1.4.1.2.6.158.3.181NodemmTrapFanSSystem Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.182NodemmTrapPwrDOSSystem Alert: Power down or on.