BLADESPPALT-MIB
89 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | -- -- IMPORTS -- OBJECT-TYPE |
| RFC-1215 | -- TRAP-TYPE |
| RFC1155-SMI | -- enterprises |
| RFC1213-MIB | -- DisplayString |
| SNMPv2-SMI | -- Unsigned32 |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2 | Nodeibm | |||
| 1.3.6.1.4.1.2.6 | NodeibmProd | |||
| 1.3.6.1.4.1.2.6.158 | NodesupportProcessor | |||
| 1.3.6.1.4.1.2.6.158.3 | NodemmRemoteSupTrapMIB | |||
| 1.3.6.1.4.1.2.6.158.3.0 | NodemmTrapTempC | Critical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.1 | NodemmTrapVoltC | Critical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.1 | NoderemoteSupTrapMibObjects | |||
| 1.3.6.1.4.1.2.6.158.3.1.1 | NodespTrapInfo | |||
| 1.3.6.1.4.1.2.6.158.3.1.1.1 | ScalarspTrapDateTime | read-only | mandatory | Timestamp of Local Date and Time when alert was generated NOTE: the format is changeable by a setting on the Management Module (Flex System only) |
| 1.3.6.1.4.1.2.6.158.3.1.1.2 | ScalarspTrapAppId | read-only | mandatory | Platform ID, either 'IBM Flex Chassis Management Module' (Flex System) or 'BladeCenter Management Module' (BladeCenter) |
| 1.3.6.1.4.1.2.6.158.3.1.1.3 | ScalarspTrapSpTxtId | read-only | mandatory | SP System Identification - Text Identification |
| 1.3.6.1.4.1.2.6.158.3.1.1.4 | ScalarspTrapSysUuid | read-only | mandatory | Host System UUID(Universal Unique ID) |
| 1.3.6.1.4.1.2.6.158.3.1.1.5 | ScalarspTrapSysSern | read-only | mandatory | 'Chassis Serial Number'(Flex System) or 'AMM Serial Number' (BladeCenter) |
| 1.3.6.1.4.1.2.6.158.3.1.1.6 | ScalarspTrapAppType | read-only | mandatory | Application Alert Type - Trap Type ID |
| 1.3.6.1.4.1.2.6.158.3.1.1.7 | ScalarspTrapPriority | read-only | mandatory | Alert Severity Value - Critical Alert(0) - Major(1) - Non-Critical Alert(2) - System Alert(4) - Recovery Alert(8) - Informational Only Alert(255) |
| 1.3.6.1.4.1.2.6.158.3.1.1.8 | ScalarspTrapMsgText | read-only | mandatory | Alert Message Text |
| 1.3.6.1.4.1.2.6.158.3.1.1.9 | ScalarspTrapHostContact | read-only | mandatory | Host Contact |
| 1.3.6.1.4.1.2.6.158.3.1.1.10 | ScalarspTrapHostLocation | read-only | mandatory | Host Location |
| 1.3.6.1.4.1.2.6.158.3.1.1.11 | ScalarspTrapBladeName | read-only | mandatory | Server Name NOTE: This will only be populated if a server event triggered this trap. |
| 1.3.6.1.4.1.2.6.158.3.1.1.12 | ScalarspTrapBladeSern | read-only | mandatory | Server Serial Number NOTE: This will only be populated if a server event triggered this trap. |
| 1.3.6.1.4.1.2.6.158.3.1.1.13 | ScalarspTrapBladeUuid | read-only | mandatory | Server UUID(Universal Unique ID) NOTE: This will only be populated if a server event triggered this trap. |
| 1.3.6.1.4.1.2.6.158.3.1.1.14 | ScalarspTrapEvtName | read-only | mandatory | The event ID in decimal (hexidecimal format may be cross referenced in InfoCenter). |
| 1.3.6.1.4.1.2.6.158.3.1.1.15 | ScalarspTrapSourceId | read-only | mandatory | The source identifier associated with the event that caused the trap - SERVPROC : event associated with the service processor - Audit : audit event (in audit l… |
| 1.3.6.1.4.1.2.6.158.3.1.1.16 | ScalarspTrapCallHomeFlag | read-only | mandatory | The call home flag associated with the event that caused the trap - No Call Home generated with this event (0) - Call Home generated with this event if call ho… |
| 1.3.6.1.4.1.2.6.158.3.1.1.17 | ScalarspTrapSysIPAddress | read-only | mandatory | The chassis Management Module IP Address. NOTE: In some very rare cases, the IP address will indicate 0.0.0.0 instead of the proper configured IP address. This… |
| 1.3.6.1.4.1.2.6.158.3.1.1.18 | ScalarspTrapSysMachineModel | read-only | mandatory | Chassis Machine Type/Model |
| 1.3.6.1.4.1.2.6.158.3.1.1.19 | ScalarspTrapBladeMachineModel | read-only | mandatory | Server Machine Type/Model NOTE: This will only be populated if a server event triggered this trap. |
| 1.3.6.1.4.1.2.6.158.3.1.1.20 | ScalarspTrapBladeFRUSerialNumber | read-only | mandatory | Server Field Replaceable Unit (FRU) Serial Number NOTE: This will only be populated if a server event triggered this trap. spTrapBladeFRUSerialNumber is only a… |
| 1.3.6.1.4.1.2.6.158.3.1.1.21 | ScalarspTrapBladeEvtName | read-only | mandatory | The server event ID. This ID can be cross referenced in the InfoCenter. NOTE: This will only be populated if a server event triggered this trap. spTrapBladeEvt… |
| 1.3.6.1.4.1.2.6.158.3.1.1.22 | ScalarspBladeEventDataSource | read-only | mandatory | The 5 bytes are values from the IPMI standard SEL (System Event Log) entry received for from server. Byte 1 (SEL Byte 11) - IPMI Standard Sensor Type Byte 2 (S… |
| 1.3.6.1.4.1.2.6.158.3.1.1.23 | ScalarspTrapAuxData | read-only | mandatory | Auxiliary data associated with the event. Truncated if more than 127 characters. NOTE: spTrapAuxData is only available on Flex System. |
| 1.3.6.1.4.1.2.6.158.3.1.1.24 | ScalarspTrapComponentID | read-only | mandatory | Component ID to associate the trap with the location in the chassis and, if applicable, the node enclosure. NOTE: spTrapComponentID is only available on Flex S… |
| 1.3.6.1.4.1.2.6.158.3.1.1.25 | ScalarspTrapComponentFRUInfo | read-only | mandatory | Field Replaceable Unit (FRU) of the component that caused the trap. NOTE: spTrapComponentFRUInfo is only available on Flex System. |
| 1.3.6.1.4.1.2.6.158.3.1.1.26 | ScalarspTrapChassisName | read-only | mandatory | Chassis Name NOTE: This will only populate if the Chassis Name has been set. spTrapChassisName is only available on Flex System. |
| 1.3.6.1.4.1.2.6.158.3.1.1.27 | ScalarspTrapSysRoomId | read-only | mandatory | Chassis Room ID NOTE: This will only populate if the Chassis Room ID has been set. spTrapSysRoomId is only available on Flex System. |
| 1.3.6.1.4.1.2.6.158.3.1.1.28 | ScalarspTrapSysRackId | read-only | mandatory | Chassis Rack ID NOTE: This will only populate if the Chassis Rack ID has been set. spTrapSysRackId is only available on Flex System. |
| 1.3.6.1.4.1.2.6.158.3.1.1.29 | ScalarspTrapSysRackU | read-only | mandatory | Chassis anchor (lowest) Rack U location NOTE: This will only populate if the Chassis lowest Rack U has been set (otherwise it will be '0'). spTrapSysRackU is o… |
| 1.3.6.1.4.1.2.6.158.3.1.1.30 | ScalarspTrapServiceableEventFlag | read-only | mandatory | The serviceable event flag associated with the event that caused the trap - the event requires no user action (0) - the event is serviceable and requires user … |
| 1.3.6.1.4.1.2.6.158.3.1.1.31 | ScalarspLogSequenceNum | read-only | mandatory | Sequence number from the chassis event log or audit log. NOTE: Audit logs are stored separately internally. spLogSequenceNum is only available on Flex System. |
| 1.3.6.1.4.1.2.6.158.3.1.1.32 | ScalarspCimMsgID | read-only | mandatory | CIM Indication Message ID NOTE: spCimMsgID is only available on Flex System. |
| 1.3.6.1.4.1.2.6.158.3.1.1.33 | ScalarspCimMsgPrefix | read-only | mandatory | CIM Indication Message ID name space, one of the following: - PLAT : DMTF platform registry - CMM : CMM message registry NOTE: spCimMsgPrefix is only available… |
| 1.3.6.1.4.1.2.6.158.3.1.1.34 | ScalarspEventCorrelator | read-only | mandatory | For events originated by the CMM: If this event is part of a event group, this will be the unique identifier from 1 - 255 for the event group. Zero means no gr… |
| 1.3.6.1.4.1.2.6.158.3.2 | NodemmTrapTampC | Critical Alert: Physical intrusion of system has occurred. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.3 | NodemmTrapMffC | Critical Alert: Multiple fan failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.4 | NodemmTrapPsC | Critical Alert: Power supply failure. | ||
| 1.3.6.1.4.1.2.6.158.3.5 | NodemTrapHdC | Critical Alert: Hard disk drive failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.6 | NodemmTrapVrmC | Critical Alert: Voltage Regulator Module(VRM) failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.7 | NodemmTrapLogFullN | Non-Critical Alert: Event Log 100% Full. | ||
| 1.3.6.1.4.1.2.6.158.3.10 | NodemmTrapRdpsN | Non-Critical Alert: Redundant Power Supply failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.11 | NodemmTrapSffC | Critical Alert: Single Fan failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.12 | NodemmTrapTempN | Non-Critical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.13 | NodemmTrapVoltN | Non-Critical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.15 | NodemmTrapSecDvS | System Alert: Secondary Device warning. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.20 | NodemmTrapPostToS | System Alert: Post Timeout value exceeded. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.21 | NodemmTrapOsToS | System Alert: OS Timeout value exceeded. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.22 | NodemmTrapAppS | System Alert: Application Alert. | ||
| 1.3.6.1.4.1.2.6.158.3.23 | NodemmTrapPoffS | System Alert: Power Off. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.24 | NodemmTrapPonS | System Alert: Power On. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.25 | NodemmTrapBootS | System Alert: System Boot Failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.26 | NodemmTrapLdrToS | System Alert: OS Loader Timeout. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.27 | NodemmTrapPFAS | System Alert: Predictive Failure Analysis(PFA) information. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.30 | NodemmTrapRemoteLoginS | System Alert: Remote Login | ||
| 1.3.6.1.4.1.2.6.158.3.31 | NodemmTrapMsC | Critical Alert: Multiple switch module failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.32 | NodemmTrapRmN | Non-Critical Alert: Redundant module. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.33 | NodemmTrapKVMSwitchS | System Alert: Keyboard/Video/Mouse(KVM) or Medial Tray(MT) switching failure. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.34 | NodemmTrapSysInvS | System Alert: Inventory. | ||
| 1.3.6.1.4.1.2.6.158.3.35 | NodemmTrapSysLogS | System Alert: System Log 75% full. | ||
| 1.3.6.1.4.1.2.6.158.3.36 | NodemmTrapIhcC | Critical Alert: Incompatible hardware configuration. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.37 | NodemmTrapNwChangeS | System Alert: Network change notification. | ||
| 1.3.6.1.4.1.2.6.158.3.39 | NodemmTrapBlThrS | System Alert: Blade Throttle. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.40 | NodemmTrapPwrMgntS | System Alert: Power Management. Note: This mib object will be replaced in a future release. | ||
| 1.3.6.1.4.1.2.6.158.3.128 | NodemmTrapBladeC | Critical Alert: Blade. | ||
| 1.3.6.1.4.1.2.6.158.3.129 | NodemmTrapIOC | Critical Alert: I/O Module. | ||
| 1.3.6.1.4.1.2.6.158.3.130 | NodemmTrapChassisC | Critical Alert: Chassis Module. | ||
| 1.3.6.1.4.1.2.6.158.3.131 | NodemmTrapStorageC | Critical Alert: Storage Module. | ||
| 1.3.6.1.4.1.2.6.158.3.133 | NodemmTrapFanC | Critical Alert: Cooling Devices. | ||
| 1.3.6.1.4.1.2.6.158.3.160 | NodemmTrapBladeN | Non-Critical Alert: Blade | ||
| 1.3.6.1.4.1.2.6.158.3.161 | NodemmTrapION | Non-Critical Alert: I/O Module | ||
| 1.3.6.1.4.1.2.6.158.3.162 | NodemmTrapChassisN | Non-Critical Alert: Chassis Module. | ||
| 1.3.6.1.4.1.2.6.158.3.163 | NodemmTrapStorageN | Non-Critical Alert: Storage Module | ||
| 1.3.6.1.4.1.2.6.158.3.164 | NodemmTrapPowerN | Non-Critical Alert: Power Module. | ||
| 1.3.6.1.4.1.2.6.158.3.165 | NodemmTrapFanN | Non-Critical Alert: Cooling Devices. | ||
| 1.3.6.1.4.1.2.6.158.3.176 | NodemmTrapBladeS | System Alert: Blade | ||
| 1.3.6.1.4.1.2.6.158.3.177 | NodemmTrapIOS | System Alert: I/O Module | ||
| 1.3.6.1.4.1.2.6.158.3.178 | NodemmTrapChassisS | System Alert: Chassis Module. | ||
| 1.3.6.1.4.1.2.6.158.3.179 | NodemmTrapStorageS | System Alert: Storage Module | ||
| 1.3.6.1.4.1.2.6.158.3.180 | NodemmTrapPowerS | System Alert: Power Module. | ||
| 1.3.6.1.4.1.2.6.158.3.181 | NodemmTrapFanS | System Alert: Cooling Devices. | ||
| 1.3.6.1.4.1.2.6.158.3.182 | NodemmTrapPwrDOS | System Alert: Power down or on. |