MIB Viewer

BLADESPPALT-MIB

74 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.6NodeibmProd
1.3.6.1.4.1.2.6.158NodesupportProcessor
1.3.6.1.4.1.2.6.158.3NodemmRemoteSupTrapMIB
1.3.6.1.4.1.2.6.158.3.0NodemmTrapTempCCritical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.1NodemmTrapVoltCCritical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.1NoderemoteSupTrapMibObjects
1.3.6.1.4.1.2.6.158.3.1.1NodespTrapInfo
1.3.6.1.4.1.2.6.158.3.1.1.1ScalarspTrapDateTimeread-onlymandatoryTimestamp of Local Date and Time when alert was generated
1.3.6.1.4.1.2.6.158.3.1.1.2ScalarspTrapAppIdread-onlymandatoryApplication ID, always 'BladeCenter Management Module'
1.3.6.1.4.1.2.6.158.3.1.1.3ScalarspTrapSpTxtIdread-onlymandatorySP System Identification - Text Identification
1.3.6.1.4.1.2.6.158.3.1.1.4ScalarspTrapSysUuidread-onlymandatoryHost System UUID(Universal Unique ID)
1.3.6.1.4.1.2.6.158.3.1.1.5ScalarspTrapSysSernread-onlymandatoryHost System Serial Number
1.3.6.1.4.1.2.6.158.3.1.1.6ScalarspTrapAppTyperead-onlymandatoryApplication Alert Type - Event Number ID
1.3.6.1.4.1.2.6.158.3.1.1.7ScalarspTrapPriorityread-onlymandatoryAlert Severity Value - Critical Alert(0) - Major(1) - Non-Critical Alert(2) - System Alert(4) - Recovery Alert(8) - Informational Only Alert(255)
1.3.6.1.4.1.2.6.158.3.1.1.8ScalarspTrapMsgTextread-onlymandatoryAlert Message Text
1.3.6.1.4.1.2.6.158.3.1.1.9ScalarspTrapHostContactread-onlymandatoryHost Contact
1.3.6.1.4.1.2.6.158.3.1.1.10ScalarspTrapHostLocationread-onlymandatoryHost Location
1.3.6.1.4.1.2.6.158.3.1.1.11ScalarspTrapBladeNameread-onlymandatoryBlade Name
1.3.6.1.4.1.2.6.158.3.1.1.12ScalarspTrapBladeSernread-onlymandatoryBlade Serial Number
1.3.6.1.4.1.2.6.158.3.1.1.13ScalarspTrapBladeUuidread-onlymandatoryBlade UUID(Universal Unique ID)
1.3.6.1.4.1.2.6.158.3.1.1.14ScalarspTrapEvtNameread-onlymandatoryThe 32 bit event name associated with the event that caused the trap
1.3.6.1.4.1.2.6.158.3.1.1.15ScalarspTrapSourceIdread-onlymandatoryThe source identifier associated with the event that caused the trap
1.3.6.1.4.1.2.6.158.3.1.1.16ScalarspTrapCallHomeFlagread-onlymandatoryThe call home flag associated with the event that caused the trap
1.3.6.1.4.1.2.6.158.3.1.1.17ScalarspTrapSysIPAddressread-onlymandatoryThe AMM IP Address. NOTE: In some very rare cases, the IP address will indicate 0.0.0.0 instead of the proper AMM configured IP address. This can happen on the…
1.3.6.1.4.1.2.6.158.3.1.1.18ScalarspTrapSysMachineModelread-onlymandatoryChassis Machine Type/Module
1.3.6.1.4.1.2.6.158.3.1.1.19ScalarspTrapBladeMachineModelread-onlymandatoryBlade Machine Type/Module
1.3.6.1.4.1.2.6.158.3.2NodemmTrapTampCCritical Alert: Physical intrusion of system has occurred. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.3NodemmTrapMffCCritical Alert: Multiple fan failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.4NodemmTrapPsCCritical Alert: Power supply failure.
1.3.6.1.4.1.2.6.158.3.5NodemTrapHdCCritical Alert: Hard disk drive failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.6NodemmTrapVrmCCritical Alert: Voltage Regulator Module(VRM) failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.7NodemmTrapLogFullNNon-Critical Alert: Event Log 100% Full.
1.3.6.1.4.1.2.6.158.3.10NodemmTrapRdpsNNon-Critical Alert: Redundant Power Supply failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.11NodemmTrapSffCCritical Alert: Single Fan failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.12NodemmTrapTempNNon-Critical Alert: Temperature threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.13NodemmTrapVoltNNon-Critical Alert: Voltage threshold exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.15NodemmTrapSecDvSSystem Alert: Secondary Device warning. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.20NodemmTrapPostToSSystem Alert: Post Timeout value exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.21NodemmTrapOsToSSystem Alert: OS Timeout value exceeded. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.22NodemmTrapAppSSystem Alert: Application Alert.
1.3.6.1.4.1.2.6.158.3.23NodemmTrapPoffSSystem Alert: Power Off. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.24NodemmTrapPonSSystem Alert: Power On. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.25NodemmTrapBootSSystem Alert: System Boot Failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.26NodemmTrapLdrToSSystem Alert: OS Loader Timeout. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.27NodemmTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.30NodemmTrapRemoteLoginSSystem Alert: Remote Login
1.3.6.1.4.1.2.6.158.3.31NodemmTrapMsCCritical Alert: Multiple switch module failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.32NodemmTrapRmNNon-Critical Alert: Redundant module. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.33NodemmTrapKVMSwitchSSystem Alert: Keyboard/Video/Mouse(KVM) or Medial Tray(MT) switching failure. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.34NodemmTrapSysInvSSystem Alert: Inventory.
1.3.6.1.4.1.2.6.158.3.35NodemmTrapSysLogSSystem Alert: System Log 75% full.
1.3.6.1.4.1.2.6.158.3.36NodemmTrapIhcCCritical Alert: Incompatible hardware configuration. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.37NodemmTrapNwChangeSSystem Alert: Network change notification.
1.3.6.1.4.1.2.6.158.3.39NodemmTrapBlThrSSystem Alert: Blade Throttle. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.40NodemmTrapPwrMgntSSystem Alert: Power Management. Note: This mib object will be replaced in a future release.
1.3.6.1.4.1.2.6.158.3.128NodemmTrapBladeCCritical Alert: Blade.
1.3.6.1.4.1.2.6.158.3.129NodemmTrapIOCCritical Alert: I/O Module.
1.3.6.1.4.1.2.6.158.3.130NodemmTrapChassisCCritical Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.131NodemmTrapStorageCCritical Alert: Storage Module.
1.3.6.1.4.1.2.6.158.3.133NodemmTrapFanCCritical Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.160NodemmTrapBladeNNon-Critical Alert: Blade
1.3.6.1.4.1.2.6.158.3.161NodemmTrapIONNon-Critical Alert: I/O Module
1.3.6.1.4.1.2.6.158.3.162NodemmTrapChassisNNon-Critical Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.163NodemmTrapStorageNNon-Critical Alert: Storage Module
1.3.6.1.4.1.2.6.158.3.164NodemmTrapPowerNNon-Critical Alert: Power Module.
1.3.6.1.4.1.2.6.158.3.165NodemmTrapFanNNon-Critical Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.176NodemmTrapBladeSSystem Alert: Blade
1.3.6.1.4.1.2.6.158.3.177NodemmTrapIOSSystem Alert: I/O Module
1.3.6.1.4.1.2.6.158.3.178NodemmTrapChassisSSystem Alert: Chassis Module.
1.3.6.1.4.1.2.6.158.3.179NodemmTrapStorageSSystem Alert: Storage Module
1.3.6.1.4.1.2.6.158.3.180NodemmTrapPowerSSystem Alert: Power Module.
1.3.6.1.4.1.2.6.158.3.181NodemmTrapFanSSystem Alert: Cooling Devices.
1.3.6.1.4.1.2.6.158.3.182NodemmTrapPwrDOSSystem Alert: Power down or on.