MIB Viewer

BRCM-CM-FACTORY-MIB

71 objects
Broadcom proprietary MIB for management and configuration of cablemodem objects used in manufacturing.
OIDNameAccessStatusDescription
1.3.6.1.4.1.4413.2.99.1.1.2.2IdentitycablemodemFactoryBroadcom proprietary MIB for management and configuration of cablemodem objects used in manufacturing.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1NodecmFactoryBase
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.1ScalarcmFactOperModeread-writecurrentReflects and controls the operational state of the device. If set to docsis(1), the CM will operate in the usual DOCSIS fashion. If set to diagnostic(2), the C…
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.2ScalarcmFactSwBcmVersionread-onlycurrentThe Broadcom internal software version identifier of this image. This is generally not the same as docsDevSwVersion.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.3ScalarcmFactSwDateTimeread-onlycurrentThe date and time that this image was built.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.4ScalarcmFactSwBuiltByread-onlycurrentThe user ID of the individual who built this image.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.5ScalarcmFactSwFeaturesread-onlycurrentA list of features supported by this image.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.6ScalarcmFactAckCelEnableread-writecurrentEnables or disables Broadcom's Patent Pending AckCel technology for the CM Upstream interface. Changes to this value take effect the next time the CM registers…
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.7ScalarcmFactNonstdUpstreamEnableread-writecurrentEnables or disables the support of non-standard upstream configurations. If enabled, the s/w will accept and use UCDs that contain proprietary non-standard mod…
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.8ScalarcmFactPowerSaveModeEnableread-writecurrentEnables or disables power save mode. With power save mode enabled, various measures will be taken to reduce power consumption. Power save mode is primarily use…
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.9ScalarcmFactOptimized3420FreqMapEnableread-writecurrentEnables or disables the use of the optimized frequency map for devices which use the 3420 tuner. Note that this object has no meaning if the device uses a tune…
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.10ScalarcmFactHighOutputPAEnableread-writecurrentEnables or disables the support of high-output power amp mode on the CM.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.11ScalarcmFactChannelBondingEnableread-writecurrentEnables or disables the support of channel bonding. Note that this setting will only have any effect if the hardware and firmware support channel bonding.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.12ScalarcmFactEnabledTunersread-writecurrentSpecifies the number of tuners which will be advertised to the CMTS in the CM's modem capabilities message. By advertising fewer tuners than the design actuall…
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.13ScalarcmFactAnnexread-writecurrentSpecifies the annex mode which will be used. This setting affects downstream tuning parameters including frequency list and phy level operation.
1.3.6.1.4.1.4413.2.99.1.1.2.2.1.14ScalarcmFactExtendedUsTxPowerCapabilityread-writecurrentSpecifies the maximum extended upstream transmit power of which this device is capable. A value of zero indicates that the device has no extended upstream powe…
1.3.6.1.4.1.4413.2.99.1.1.2.2.2NodecmFactoryBaselinePrivacy
1.3.6.1.4.1.4413.2.99.1.1.2.2.2.1ScalarcmBpiPublicKeyread-writecurrentThe baseline privacy public key for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.2.2ScalarcmBpiPrivateKeyread-writecurrentThe baseline privacy public key for this device. In order to prevent unauthorized discovery of the private key, when read this object does not return the key. …
1.3.6.1.4.1.4413.2.99.1.1.2.2.2.3ScalarcmBpiPlusRootPublicKeyread-writecurrentThe baseline privacy plus root public key for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.2.4ScalarcmBpiPlusCmCertificateread-writecurrentThe baseline privacy plus CM certificate for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.2.5ScalarcmBpiPlusCaCertificateread-writecurrentThe baseline privacy plus CA certificate for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.3NodecmFactoryDownstreamCalibration
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.1ScalarcmDsCalFrequencyread-writecurrentThe center of the downstream frequency to which the CM will attempt to lock when cmDsCalLockNow is set to true. Note that a read of this object does NOT necess…
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.2ScalarcmDsCalModulationread-writecurrentThe modulation type that the CM will attempt to lock under when cmDsCalLockNow is set to true. Note that a read of this object does NOT necessarily indicate th…
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.3ScalarcmDsCalLockNowread-writecurrentWhen this object is set to true(1), the CM will attempt to lock to the downstream channel at a frequency specified by cmDsCalFrequency, and under the modulatio…
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.4ScalarcmDsCalQamLockedread-onlycurrentIndicates whether the last set of cmDsCalLockNow to true resulted in the CM acheiving QAM lock. Note that changing cmDsCalFrequency or cmDsCalModulation will n…
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.5ScalarcmDsCalFecLockedread-onlycurrentIndicates whether the last set of cmDsCalLockNow to true resulted in the CM acheiving FEC lock. Note that changing cmDsCalFrequency or cmDsCalModulation will n…
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.6ScalarcmDsCalZeroOffsetsread-writecurrentSetting this object to true(1) will result in all instances of cmDsCalOffset being set to a value of 0. Sets to false(2) will be accepted, but will not result …
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.7ScalarcmDsCalNumOffsetsread-writecurrentThis object is read-only in normal factory mode, ie when cableDataPrivateMibEnable is set to factory(1). In that context it simply indicates the number of entr…
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.8TablecmDsCalOffsetTablenot-accessiblecurrentA list offsets to be used when calculating downstream power for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.8.1RowcmDsCalOffsetEntrynot-accessiblecurrentAn entry defining the offset from calculated power at a given downstream frequency for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.8.1.1ColumncmDsCalOffsetIndexnot-accessiblecurrentIdentifies the instance of this downstream calibration offset.
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.8.1.2ColumncmDsCalOffsetFrequencyread-writecurrentThe downstream frequency at which this instance of cmDsCalOffsetPower. applies. In normal factory mode, ie if cableDataPrivateMibEnable is set to factory(1), t…
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.8.1.3ColumncmDsCalOffsetPowerread-writecurrentThe offset from calculated downstream power that should be applied for this device at the corresponding instance of cmDsCalOffsetFrequency.
1.3.6.1.4.1.4413.2.99.1.1.2.2.3.9ScalarcmDsCalChannelNumberread-writecurrentFor bonded downstream systems, this object identifies which downstream channel is to be calibrated. When the value of this object is changed, the cmDsCalOffset…
1.3.6.1.4.1.4413.2.99.1.1.2.2.4NodecmFactoryUpstreamCalibration
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.1ScalarcmUsCalFrequencyread-writecurrentThe center of the upstream frequency on which the CM will transmit when cmUsCalTxPower is set. Note that a read of this object does NOT necessarily indicate th…
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.2ScalarcmUsCalChannelWidthread-writecurrentThe bandwidth of the upstream transmission which will be intiated by a set to cmUsCalTxPower. This object may be converted by a constant of 1250000 to the symb…
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.3ScalarcmUsCalModulationread-writecurrentThe modulation type that the CM will transmit under when cmUsCalTxPower is set. Note that a read of this object does NOT necessarily indicate that the CM is cu…
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.4ScalarcmUsCalTxPowerread-writecurrentA set of this object will cause the CM to begin transmitting upstream at the specified power level to the best of its ability based on current upstream calibra…
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.5ScalarcmUsCalZeroOffsetsread-writecurrentSetting this object to true(1) will result in all instances of cmUsCalOffset being set to a value of 0. Sets to false(2) will be accepted, but will not result …
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.6ScalarcmUsCalNumOffsetsread-onlycurrentIndicates the number of entries in the cmUsCalOffsetTable.
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.7TablecmUsCalOffsetTablenot-accessiblecurrentA list offsets to be used when calculating upstream power for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.7.1RowcmUsCalOffsetEntrynot-accessiblecurrentAn entry defining the offset from calculated power at a given upstream frequency for this device.
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.7.1.1ColumncmUsCalOffsetIndexnot-accessiblecurrentIdentifies the instance of this upstream calibration offset.
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.7.1.2ColumncmUsCalOffsetFrequencyread-onlycurrentThe upstream frequency at which this instance of cmUsCalOffsetPower. applies.
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.7.1.3ColumncmUsCalOffsetPowerread-writecurrentThe offset from calculated upstream power that should be applied for this device at the corresponding instance of cmUsCalOffsetFrequency.
1.3.6.1.4.1.4413.2.99.1.1.2.2.4.8ScalarcmUsCalChannelNumberread-writecurrentFor bonded upstream systems, this object identifies which upstream channel is to be calibrated. When the value of this object is changed, the cmUsCalOffsetTabl…
1.3.6.1.4.1.4413.2.99.1.1.2.2.5NodecmFactoryHardware
1.3.6.1.4.1.4413.2.99.1.1.2.2.5.1ScalarcmHwSTATHRread-writecurrentAGC Loop Threshold
1.3.6.1.4.1.4413.2.99.1.1.2.2.5.2ScalarcmHwSTAGIread-writecurrentIF AGC Gain Threshold
1.3.6.1.4.1.4413.2.99.1.1.2.2.5.3ScalarcmHwSTAGTread-writecurrentRF (Tuner) AGC Gain Threshold
1.3.6.1.4.1.4413.2.99.1.1.2.2.5.4ScalarcmHwAdvanceMapRunAheadEnableread-writecurrentEnables/disables Advance Map RunAhead support on supported hardware platforms. Advance Map RunAhead feature uses an additional Docsis Map processor to provide …
1.3.6.1.4.1.4413.2.99.1.1.2.2.6NodecmFactoryOtp
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.1ScalarcmOtpIsProgrammedread-onlycurrentIndicates if the OTP section of this chip has been programmed. Note that if this object returns true(1), all objects in this group will be read-only and any at…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.2ScalarcmOtpProgramNowread-writecurrentIf set to true(1), initiates programming of the OTP. Setting to false(2) has no effect. Always returns false(2) when read. Note that setting this object to tru…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.3ScalarcmOtpProgramResultread-onlycurrentIndicates the result of an attempt to program the OTP. Note that this value does not persist across a reboot, but it will provide the result of an attempt to p…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.4ScalarcmOtpRawBitsSizeread-onlycurrentIndicates the size of the OTP region in bits.
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.5ScalarcmOtpRawBitsread-writecurrentAllows reading or writing the OTP region as a raw hex value. When reading, note that only the right-most bits are valid. The number of valid bits is returned b…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.6ScalarcmOtpCustomerDefinedBitsSizeread-onlycurrentIndicates the size of the customer defined region in bits.
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.7ScalarcmOtpCustomerDefinedBitsread-writecurrentAllows reading or writing the customer defined region as a raw hex value. When reading, note that only the right-most bits are valid. The number of valid bits …
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.8ScalarcmOtpSecurityLevelread-writecurrentReports and controls the current security level for the cumulative set of supported OTP features for this device. This provides a platform-independent mechanis…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.9ScalarcmOtpJtagDisabledread-writecurrentIf set to true(1), disables JTAG in hardware. If set to false(2), JTAG will remain enabled. Setting cmOtpSecurityLevel to fullSecurity(2) will cause the value …
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.10ScalarcmOtpConsoleDisabledread-writecurrentIf set to true(1), disables the serial console port in hardware. If set to false(2), serial console will remain enabled. Setting cmOtpSecurityLevel to fullSecu…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.11ScalarcmOtpSpiSlaveDisabledread-writecurrentIf set to true(1), disables the SPI slave in hardware. If set to false(2), the SPI slave will remain enabled. Setting cmOtpSecurityLevel to fullSecurity(2) wil…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.12ScalarcmOtpMpiAccessControlread-writecurrentIndicates the value of the MPI access control setting. The effect of setting cmOtpSecurityLevel on the value of this object is platform-dependant.
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.13ScalarcmOtpBootRomEnabledread-writecurrentIf set to true(1), the part will boot only from ROM. If set to false(2), the part will boot from a bootloader in flash. Setting cmOtpSecurityLevel to fullSecur…
1.3.6.1.4.1.4413.2.99.1.1.2.2.6.14ScalarcmOtpRamScramblerEnabledread-writecurrentEnables or disables the RAM scrambler. Setting cmOtpSecurityLevel to fullSecurity(2) will cause the value of this object to be set to true(1). Setting cmOtpSec…
1.3.6.1.4.1.4413.2.99.1.1.2.2.7NodecmFactoryFpm
1.3.6.1.4.1.4413.2.99.1.1.2.2.7.1ScalarcmFpmTokenDepletionWatchdogEnableread-writecurrentEnables or disables the free pool manager token watchdog feature. If enabled, this feature causes the CM to reboot if the FPM becomes depleted of tokens.