BRCM-THERMAL-MGMT-MIB
9 objects
Broadcom proprietary MIB for runtime management and configuration of objects related to thermal monitor.
Imported Objects
| BRCM-CABLEDATA-MGMT-MIB | cableDataMgmtMIBObjects |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime DisplayString TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4413.2.2.2.1.11 | IdentitythermalMgmt | Broadcom proprietary MIB for runtime management and configuration of objects related to thermal monitor. | ||
| 1.3.6.1.4.1.4413.2.2.2.1.11.1 | NodethermalMgmtBase | |||
| 1.3.6.1.4.1.4413.2.2.2.1.11.1.1 | ScalarthermalCurrentTemperature | read-only | current | The Current Temperature of the Unit. |
| 1.3.6.1.4.1.4413.2.2.2.1.11.1.2 | ScalarthermalPowerOffThreshold | read-write | current | Specifies the Temperature Threshold at which the Thermal Shutdown Controller will power down the unit. (40C to 120C). Note PowerOffThreshold must be greater th… |
| 1.3.6.1.4.1.4413.2.2.2.1.11.1.3 | ScalarthermalPowerOnThreshold | read-write | current | Specifies the Temperature Threshold at which the Thermal Shutdown Controller will switch power back on. (40C to 120C). Note PowerOnThreshold must be less than … |
| 1.3.6.1.4.1.4413.2.2.2.1.11.1.4 | ScalarthermalPowerOnDelay | read-write | current | This delay specifies the time between the Thermal Shutdown Controller detecting that the Power On Threshold has been reached and when it actually switches the … |
| 1.3.6.1.4.1.4413.2.2.2.1.11.1.5 | ScalarthermalPowerOffDelay | read-write | current | This delay is used to ensure the remainder of the board is completely powered down prior to the Thermal Shutdown Circuit entering Over Temperature state. Becau… |
| 1.3.6.1.4.1.4413.2.2.2.1.11.1.6 | ScalarthermalNotificationDelay | read-write | current | This delay is used to allow the main processor time to clean up (i.e. preserve state information in non-volatile memory, and/or gracefully shut down a battery … |
| 1.3.6.1.4.1.4413.2.2.2.1.11.1.7 | ScalarthermalMonitorInitialized | read-only | current | This object returns true if the thermal monitor has been successfully initialized. |