MIB Viewer

Baytech-MIB-401-4

246 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises Gauge IpAddress TimeTicks
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.4779Nodebaytech
1.3.6.1.4.1.4779.1Nodebtadevices
1.3.6.1.4.1.4779.1NodecommunicationLostSEVERE: Communication to the unit has been lost. Steps to reestablish communication are in progress. Argument is timeTicks when communication was lost.
1.3.6.1.4.1.4779.1.1NodesBTAIdent
1.3.6.1.4.1.4779.1.1.1ScalarsBTAIdentFirmwareRevread-onlymandatoryAn 8 byte ID string identifying the DS72 firmware revision. This value is set at the factory.
1.3.6.1.4.1.4779.1.1.2ScalarsBTAIdentSerialNumberread-onlymandatoryA number identifying the serial number of the DS72. This value is set at the factory.
1.3.6.1.4.1.4779.1.1.3ScalarsBTAIdentUnitNameread-writemandatoryA 64-character string identifying the name (UnitID) of the DS72. This value is set at the factory to a default of DS72.
1.3.6.1.4.1.4779.1.2NodesBTANetworkConfig
1.3.6.1.4.1.4779.1.2.1ScalarsBTANetworkConfigBootpEnableread-writemandatoryEnables/disables bootp. Bootp will not take effect until the unit is reseted.
1.3.6.1.4.1.4779.1.2.2ScalarsBTANetworkConfigDHCPEnableread-writemandatoryEnables/disables DHCP. DHCP will not take effect until the unit is reseted.
1.3.6.1.4.1.4779.1.2.3ScalarsBTANetworkConfigSSHEnableread-writemandatoryEnables/disables SSH logins. Disable/enable SSH will take effect after the unit is reseted.
1.3.6.1.4.1.4779.1.2.4ScalarsBTANetworkConfigTelnetEnableread-writemandatoryEnables/disables telnet.
1.3.6.1.4.1.4779.1.2.5ScalarsBTANetworkConfigActivityTimeoutread-writemandatoryA value from 0 to 120. 0 disables activity timeouts. Value represents minutes of non-activity before telnet / SSH sessions are automatically logged out. Defaul…
1.3.6.1.4.1.4779.1.2.6ScalarsBTANetworkConfigDirectConnEnableread-writemandatoryEnables/disables direct port connection upon login.
1.3.6.1.4.1.4779.1.2.8NodesBTANetworkConfigSNMP
1.3.6.1.4.1.4779.1.2.8.1ScalarsBTANetworkConfigSNMPReadOnlyCommunityread-writemandatoryThe community name to use for read only access. Maximum len 16 bytes.
1.3.6.1.4.1.4779.1.2.8.2ScalarsBTANetworkConfigSNMPReadWriteCommunityread-writemandatoryThe community name to use for read-write access. Maximum len 16 bytes.
1.3.6.1.4.1.4779.1.2.8.3ScalarsBTANetworkConfigSNMPNumTrapReceiversread-onlymandatoryThe maximum number of managers to send traps to. Currently 4.
1.3.6.1.4.1.4779.1.2.8.4TablesBTANetworkConfigSNMPTrapReceiverTablenot-accessiblemandatoryA list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is …
1.3.6.1.4.1.4779.1.2.8.4.1RowsBTANetworkConfigSNMPTrapReceiverEntrynot-accessiblemandatoryTable of managers to send traps to.
1.3.6.1.4.1.4779.1.2.8.4.1.1ColumntrapIndexread-onlymandatoryThe index to a trap receiver entry.
1.3.6.1.4.1.4779.1.2.8.4.1.2ColumnreceiverAddressread-writemandatoryThe IP address of the manager to send traps to.
1.3.6.1.4.1.4779.1.2.9NodesBTANetworkConfigRadius
1.3.6.1.4.1.4779.1.2.9.1ScalarsBTANetworkConfigRadiusEnableread-writemandatoryEnables / disables RADIUS telnet logins.
1.3.6.1.4.1.4779.1.2.9.2ScalarsBTANetworkConfigRadiusPrimaryServerread-writemandatoryIp address of the primary RADIUS server.
1.3.6.1.4.1.4779.1.2.9.3ScalarsBTANetworkConfigRadiusSecondaryServerread-writemandatoryIp address of the back-up RADIUS server.
1.3.6.1.4.1.4779.1.2.9.4ScalarsBTANetworkConfigRadiusLocalLoginread-writemandatoryEnables / disables the use of local (usernames stored in the DS72) logins in the case that both the primary and secondary RADIUS server are not available.
1.3.6.1.4.1.4779.1.2.10NodesBTANetworkConfigWEB
1.3.6.1.4.1.4779.1.2.10.1ScalarsBTANetworkConfigWebEnableread-writemandatoryEnables WEB.
1.3.6.1.4.1.4779.1.2.10.2ScalarsBTANetworkConfigWebSecureEnableread-writemandatoryEnables WEB Security.
1.3.6.1.4.1.4779.1.2.10.3ScalarsBTANetworkConfigWebLoginEnableread-writemandatoryEnables WEB Login.
1.3.6.1.4.1.4779.1.2.10.4ScalarsBTANetworkConfigWebActivityTimeoutread-writemandatoryA value from 0 to 120. 0 disables WEB activity timeouts. Value represents minutes of non-activity before WEB sessions are automatically logged out. Default is …
1.3.6.1.4.1.4779.1.3NodesBTAModules
1.3.6.1.4.1.4779.1.3.1ScalarsBTAModulesNumberOfModulesread-onlymandatoryNumber of modules installed into the DS unit.
1.3.6.1.4.1.4779.1.3.2ScalarsBTAModulesModulesInstalledread-onlymandatoryA character string listing the modules installed seperated by commas. Each module is identifed by a two digit number indicating the slot. For example 02,03,04,…
1.3.6.1.4.1.4779.1.3.3ScalarsBTAModulesResetModulesCmdread-onlydeprecatedThis command is no longer supported.
1.3.6.1.4.1.4779.1.3.4ScalarsBTAModulesNumberOfIntelligentModulesread-onlymandatoryThe number of Intelligent Modules installed in the DS Unit.
1.3.6.1.4.1.4779.1.3.5NodesBTAModulesRPC
1.3.6.1.4.1.4779.1.3.5.1ScalarsBTAModulesNumberOfRPCModulesread-onlymandatoryThe number of DS30 Modules installed in the DS Unit.
1.3.6.1.4.1.4779.1.3.5.2TablesBTAModulesRPCTablenot-accessiblemandatoryAllows for control of individual outlets and individual RPC modules.
1.3.6.1.4.1.4779.1.3.5.2.1RowsBTAModulesRPCEntrynot-accessiblemandatoryThe RPCs to control and get status on.
1.3.6.1.4.1.4779.1.3.5.2.1.1ColumnsBTAModulesRPCIndexread-onlymandatoryThe index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula: ((module - 2) * 4) + port. For example module…
1.3.6.1.4.1.4779.1.3.5.2.1.2ColumnsBTAModulesRPCNameread-writemandatoryThe name (unit id) of the rpc.
1.3.6.1.4.1.4779.1.3.5.2.1.3ColumnsBTAModulesRPCFirmwareVersionread-onlymandatoryThe firware version of the rpc.
1.3.6.1.4.1.4779.1.3.5.2.1.4ColumnsBTAModulesRPCCurrentread-onlymandatoryThe current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.5ColumnsBTAModulesRPCMaxCurrentread-writemandatoryThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will c…
1.3.6.1.4.1.4779.1.3.5.2.1.6ColumnsBTAModulesRPCVoltageread-onlymandatoryThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.7ColumnsBTAModulesRPCPowerread-onlymandatoryThe power reading for the power strip. If power measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.8ColumnsBTAModulesRPCTemperatureread-onlymandatoryThe temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.2.1.9ColumnsBTAModulesRPCRebootTimeoutread-onlymandatoryThe length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
1.3.6.1.4.1.4779.1.3.5.2.1.10ColumnsBTAModulesRPCAllOutletsCmdread-writemandatoryTurns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot A get will return unknown (6).
1.3.6.1.4.1.4779.1.3.5.2.1.11ColumnsBTAModulesRPCAllOutletsStatusread-onlymandatoryReports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
1.3.6.1.4.1.4779.1.3.5.2.1.12ColumnsBTAModulesRPCCurrentAlarmThresholdread-writemandatoryThe current alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.2.1.13ColumnsBTAModulesRPCOverVoltageThresholdread-writemandatoryThe over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.2.1.14ColumnsBTAModulesRPCUnderVoltageThresholdread-writemandatoryThe under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.2.1.15ColumnsBTAModulesRPCNumberOfOutletsread-onlymandatoryNumber of outlets for this RPC. This will be the size of outlet table for this RPC index.
1.3.6.1.4.1.4779.1.3.5.2.1.16ColumnsBTAModulesRPCCircuitBreakerread-onlymandatoryStatus of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.2.1.17ColumnsBTAModulesRPCOverTempThresholdread-writemandatoryThe over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
1.3.6.1.4.1.4779.1.3.5.2.1.18ColumnsBTAModulesRPCUnitVAread-onlymandatoryTotal Volt-Amps for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.19ColumnsBTAModulesRPCNumberOfBreakersread-onlymandatoryNumber of breakers for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.20ColumnsBTAModulesRPCLowCurrentThresholdread-writemandatoryLow current threshold for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.21ColumnsBTAModulesRPCVoltageSourceread-writemandatoryVoltage source for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.22ColumnsBTAModulesRPCSourceSwitchCountread-onlymandatoryCount of Voltage Source Switches for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.23ColumnsBTAModulesRPCNumberOfSensorsread-onlymandatoryNumber of environmental sensors for this RPC.
1.3.6.1.4.1.4779.1.3.5.2.1.24ColumnsBTAModulesRPCTyperead-onlymandatoryThe type of RPC installed at the indexed location.
1.3.6.1.4.1.4779.1.3.5.3TablesBTAModulesRPCOutletTablenot-accessiblemandatoryAllows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
1.3.6.1.4.1.4779.1.3.5.3.1RowsBTAModulesRPCOutletEntrynot-accessiblemandatoryThe outlets to control and get status on.
1.3.6.1.4.1.4779.1.3.5.3.1.1ColumnsBTAModulesRPCOutletModuleIndexread-onlymandatoryThe index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.3.1.2ColumnsBTAModulesRPCOutletIndexread-onlymandatoryThe index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.3.1.3ColumnsBTAModulesRPCOutletStateread-writemandatoryGetting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (out…
1.3.6.1.4.1.4779.1.3.5.3.1.4ColumnsBTAModulesRPCOutletNameread-writemandatoryThe name of the outlet. Maximum size is 16 characters.
1.3.6.1.4.1.4779.1.3.5.4ScalarsBTAModulesRPCGroupCmdread-writemandatoryA character string listing the outlets that need to be controlled, turned off, or turn on as a group. Command is the first character followed by a space. Valid…
1.3.6.1.4.1.4779.1.3.5.5TablesBTAModulesRPCModPortTablenot-accessiblemandatoryAllows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID.
1.3.6.1.4.1.4779.1.3.5.5.1RowsBTAModulesRPCModPortEntrynot-accessiblemandatoryThe RPCs to control and get status on.
1.3.6.1.4.1.4779.1.3.5.5.1.1ColumnsRPCModuleIndexread-onlymandatoryThe module number index into the RPC table.
1.3.6.1.4.1.4779.1.3.5.5.1.2ColumnsRPCPortIndexread-onlymandatoryThe port number index into the RPC table. In the case of ds30 modules this number is always 1.
1.3.6.1.4.1.4779.1.3.5.5.1.3ColumnsRPCTyperead-onlymandatoryType of RPC at the module, port index.
1.3.6.1.4.1.4779.1.3.5.5.1.4ColumnsRPCNameread-writemandatoryThe name (unit id) of the rpc module.
1.3.6.1.4.1.4779.1.3.5.5.1.5ColumnsRPCFirmwareVersionread-onlymandatoryThe firware version of the rpc module.
1.3.6.1.4.1.4779.1.3.5.5.1.6ColumnsRPCCurrentread-onlymandatoryThe current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.7ColumnsRPCMaxCurrentread-writemandatoryThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will c…
1.3.6.1.4.1.4779.1.3.5.5.1.8ColumnsRPCVoltageread-onlymandatoryThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.9ColumnsRPCPowerread-onlymandatoryThe power reading for the power strip. If power measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.10ColumnsRPCTemperatureread-onlymandatoryThe temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.5.1.11ColumnsRPCRebootTimeoutread-writemandatoryThe length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
1.3.6.1.4.1.4779.1.3.5.5.1.12ColumnsRPCAllOutletsCmdread-writemandatoryTurns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlo…
1.3.6.1.4.1.4779.1.3.5.5.1.13ColumnsRPCAllOutletsStatusread-onlymandatoryReports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
1.3.6.1.4.1.4779.1.3.5.5.1.14ColumnsRPCCurrentAlarmThresholdread-writemandatoryThe current alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.5.1.15ColumnsRPCOverVoltageThresholdread-writemandatoryThe over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.5.1.16ColumnsRPCUnderVoltageThresholdread-writemandatoryThe under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.5.1.17ColumnsRPCNumberOfOutletsread-onlymandatoryNumber of outlets for this RPC. This will be the size of outlet table for this RPC index.
1.3.6.1.4.1.4779.1.3.5.5.1.18ColumnsRPCCircuitBreakerread-onlymandatoryStatus of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.5.1.19ColumnsRPCOverTempThresholdread-writemandatoryThe over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
1.3.6.1.4.1.4779.1.3.5.5.1.20ColumnsRPCUnitVAread-onlymandatoryNumber of outlets for this RPC. This will be the size of outlet table for this RPC index.
1.3.6.1.4.1.4779.1.3.5.5.1.21ColumnsRPCNumberOfBreakersread-onlymandatoryNumber of breakers for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.22ColumnsRPCLowCurrentThresholdread-writemandatoryLow current threshold for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.23ColumnsRPCVoltageSourceread-writemandatoryVoltage source for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.24ColumnsRPCSourceSwitchCountread-writemandatoryVoltage source switch count for this RPC.
1.3.6.1.4.1.4779.1.3.5.5.1.25ColumnsRPCNumberOfSensorsread-onlymandatoryNumber of sensors for this RPC.
1.3.6.1.4.1.4779.1.3.5.6TablesBTAModulesRPCModPortOutletTablenot-accessiblemandatoryAllows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
1.3.6.1.4.1.4779.1.3.5.6.1RowsBTAModulesRPCModPortOutletEntrynot-accessiblemandatoryThe outlets to control and get status on.
1.3.6.1.4.1.4779.1.3.5.6.1.1ColumnsRPCOutletModuleIndexread-onlymandatoryThe module index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.6.1.2ColumnsRPCOutletPortIndexread-onlymandatoryThe port index to the outlet entry. In the case of ds30s this number is always 1.
1.3.6.1.4.1.4779.1.3.5.6.1.3ColumnsRPCOutletIndexread-onlymandatoryThe outlet index to the outlet entry.
1.3.6.1.4.1.4779.1.3.5.6.1.4ColumnsRPCOutletStateread-writemandatoryGetting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (out…
1.3.6.1.4.1.4779.1.3.5.6.1.5ColumnsRPCOutletNameread-writemandatoryThe name of the outlet. Maximum size is 16 characters.
1.3.6.1.4.1.4779.1.3.5.7ScalarsBTAModulesRPCModPortGroupCmdread-writemandatoryA character string listing the outlets that need to be rebooted, turned off, or turn on as a group. Command is the first character followed by a space. Valid c…
1.3.6.1.4.1.4779.1.3.5.8TablesBTAModulesRPCCurrentGroupsCurrentTablenot-accessiblemandatoryA list of total current for RPCs in each current group
1.3.6.1.4.1.4779.1.3.5.8.1RowsBTAModulesRPCCurrentGroupsCurrentEntrynot-accessiblemandatoryTable of total current measurement by group
1.3.6.1.4.1.4779.1.3.5.8.1.1ColumngroupCurrentIndexread-onlymandatoryThe index to a group total current.
1.3.6.1.4.1.4779.1.3.5.8.1.2ColumngroupCurrentread-onlymandatoryCurrent total for all RPCs in group.
1.3.6.1.4.1.4779.1.3.5.8.1.3ColumnrpcGroupread-writemandatoryA character string listing the RPCs, by port index, that will be included in a measurement of total current. For each group, a sum will be periodically compute…
1.3.6.1.4.1.4779.1.3.5.8.1.4ColumnwarningThresholdread-writemandatoryThe current level, in tenths of an amp, that will cause a Current Level Warning trap to be sent if the total current for the associated group if exceeded. Conv…
1.3.6.1.4.1.4779.1.3.5.8.1.5ColumnemergencyThresholdread-writemandatoryThe current level, in tenths of an amp, that will cause a Current Level Emergency trap to be sent if the total current for the associated group if exceeded. Co…
1.3.6.1.4.1.4779.1.3.5.9TablesBTAModulesRPCBreakersTablenot-accessiblemandatoryAllows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.3.5.9.1RowsBTAModulesRPCBreakersEntrynot-accessiblemandatoryStatus organization by breaker.
1.3.6.1.4.1.4779.1.3.5.9.1.1ColumnsBTAModulesRPCBreakersModulesIndexread-onlymandatoryThe index into the RPC table.
1.3.6.1.4.1.4779.1.3.5.9.1.2ColumnsBTAModulesRPCBreakersBreakersIndexread-onlymandatoryThe index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.9.1.3ColumnsBTAModulesRPCBreakersCircuitBreakerread-onlymandatoryStatus of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.9.1.4ColumnsBTAModulesRPCBreakersCurrentread-onlymandatoryThe detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.5ColumnsBTAModulesRPCBreakersMaxCurrentread-onlymandatoryThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.6ColumnsBTAModulesRPCBreakersVoltageread-onlymandatoryThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.7ColumnsBTAModulesRPCBreakersPowerread-onlymandatoryThe power reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.8ColumnsBTAModulesRPCBreakersVAread-onlymandatoryThe volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.9.1.9ColumnsBTAModulesRPCBreakersCurrentAlarmThresholdread-writemandatoryThe current alarm threshold level *10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.5.10TablesRPCModPortBreakersTablenot-accessiblemandatoryAllows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.3.5.10.1RowsRPCModPortBreakersEntrynot-accessiblemandatoryStatus organization by breaker.
1.3.6.1.4.1.4779.1.3.5.10.1.1ColumnsRPCBreakersModIndexread-onlymandatoryThe module index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.10.1.2ColumnsRPCBreakersPortIndexread-onlymandatoryThe port index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.10.1.3ColumnsRPCBreakersBreakersIndexread-onlymandatoryThe breaker index into the RPC breaker table.
1.3.6.1.4.1.4779.1.3.5.10.1.4ColumnsRPCBreakersCircuitBreakerread-onlymandatoryStatus of circuit breaker in power strip. 0=off 1=on.
1.3.6.1.4.1.4779.1.3.5.10.1.5ColumnsRPCBreakersCurrentread-onlymandatoryThe detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.6ColumnsRPCBreakersMaxCurrentread-onlymandatoryThe maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.7ColumnsRPCBreakersVoltageread-onlymandatoryThe voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.8ColumnsRPCBreakersPowerread-onlymandatoryThe power reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.9ColumnsRPCBreakersVAread-onlymandatoryThe volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
1.3.6.1.4.1.4779.1.3.5.10.1.10ColumnsRPCBreakersCurrentAlarmThresholdread-writemandatoryThe current alarm threshold level x10. A value of 105 will set the level to 10.5.
1.3.6.1.4.1.4779.1.3.6NodesBTAModulesSerial
1.3.6.1.4.1.4779.1.3.7NodesBTAModulesModem
1.3.6.1.4.1.4779.1.4NodesBTAControl
1.3.6.1.4.1.4779.1.4.1ScalarsBTAControlResetUnitread-writemandatorySetting this value to 1 will cause the unit to reset. A get of this OID will return 0.
1.3.6.1.4.1.4779.1.4.2ScalarsBTAControlResetModulesread-writemandatorySetting this value to 1 will cause the unit to reset modules simular to the telnet RM command. A get of this OID will return 0.
1.3.6.1.4.1.4779.1.4.3ScalarsBTAControlNumOfLoggedUsersread-onlymandatoryNumber of users logged in via telnet or SSH.
1.3.6.1.4.1.4779.1.4.4TablesBTAControlUserTablenot-accessiblemandatoryA list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
1.3.6.1.4.1.4779.1.4.4.1RowsBTAControlUserEntrynot-accessiblemandatoryThe users to get status on.
1.3.6.1.4.1.4779.1.4.4.1.1ColumnsBTAControlUserIndexread-onlymandatoryThe index to the user entry.
1.3.6.1.4.1.4779.1.4.4.1.2ColumnsBTAControlUserNameread-onlymandatoryThe username of the user.
1.3.6.1.4.1.4779.1.4.4.1.3ColumnsBTAControlUserAddressread-onlymandatoryThe IP address of the user.
1.3.6.1.4.1.4779.1.4.4.1.4ColumnsBTAControlUserConnectionread-onlymandatoryType of connection. If unknown, user is logging out or the connection is invalid.
1.3.6.1.4.1.4779.1.4.4.1.5ColumnsBTAControlUserConnModuleread-onlymandatoryIf the user is connected to a module, this value will report the module number connected to. If the value is 0 the user is not connected to a module.
1.3.6.1.4.1.4779.1.4.4.1.6ColumnsBTAControlUserConnPortread-onlymandatoryThe port number with in a module that the user is connected to. This usually only applies to connections to DS74 serial modules. Intelligent modules connection…
1.3.6.1.4.1.4779.1.4.4.1.7ColumnsBTAControlUserTerminateUserread-writemandatorySettings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.
1.3.6.1.4.1.4779.1.5NodesBTAFileTransfer
1.3.6.1.4.1.4779.1.5.1ScalarsBTAFileTransferEnableUpgradeFTPFileTransferread-writemandatorySetting this OID to enableUpgradeFileTransferDownloadViaFTP (1) will start the FTP server and place the DS72 in upgrade mode. An FTP connection may then be est…
1.3.6.1.4.1.4779.1.6NodesBTAEnvironmental
1.3.6.1.4.1.4779.1.6.1TablesBTAModulesEnvironmentalObjectsTablenot-accessiblemandatoryAllows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.6.1.1RowsBTAModulesEnvironmentalObjectsEntrynot-accessiblemandatoryStatus organization by sensor.
1.3.6.1.4.1.4779.1.6.1.1.1ColumnsBTAModulesEnvironmentalModulesIndexread-onlymandatoryModule Index for Environemntal table
1.3.6.1.4.1.4779.1.6.1.1.2ColumnsBTAModulesEnvironmentalSensorsIndexread-onlymandatorySensor Index for Environemntal table
1.3.6.1.4.1.4779.1.6.1.1.3ColumnsBTAModulesEnvironmentalTyperead-onlymandatoryEnvironmental Object Type.
1.3.6.1.4.1.4779.1.6.1.1.4ColumnsBTAModulesEnvironmentalNameread-writemandatoryThe name for the environmental object.
1.3.6.1.4.1.4779.1.6.1.1.5ColumnsBTAModulesEnvironmentalMeasurementread-onlymandatoryThe measurement or state for the object.
1.3.6.1.4.1.4779.1.6.1.1.6ColumnsBTAModulesEnvironmentalHiThresholdread-writemandatoryHi threshold for object.
1.3.6.1.4.1.4779.1.6.1.1.7ColumnsBTAModulesEnvironmentalLoThresholdread-writemandatoryLo threshold for object.
1.3.6.1.4.1.4779.1.6.1.1.8ColumnsBTAModulesEnvironmentalMaxread-writemandatoryMax value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.1.1.9ColumnsBTAModulesEnvironmentalMinread-writemandatoryMin value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.1.1.10ColumnsBTAModulesEnvironmentalHiThresholdEnread-writemandatoryHi threshold enable for object.
1.3.6.1.4.1.4779.1.6.1.1.11ColumnsBTAModulesEnvironmentalLoThresholdEnread-writemandatoryLo threshold enable for object.
1.3.6.1.4.1.4779.1.6.1.1.12ColumnsBTAModulesEnvironmentalStateTrapEnread-writemandatoryTrap enable for environmental sensors with contacts.
1.3.6.1.4.1.4779.1.6.2TablesRPCEnvironmentalObjectsTablenot-accessiblemandatoryAllows monitoring of individual outlet strips on RPCs.
1.3.6.1.4.1.4779.1.6.2.1RowsRPCEnvironmentalObjectsEntrynot-accessiblemandatoryStatus organization by sensor.
1.3.6.1.4.1.4779.1.6.2.1.1ColumnsRPCEnvironmentalModuleIndexread-onlymandatoryModule Index for Environemntal table
1.3.6.1.4.1.4779.1.6.2.1.2ColumnsRPCEnvironmentalPortIndexread-onlymandatoryPort Index for Environemntal table
1.3.6.1.4.1.4779.1.6.2.1.3ColumnsRPCEnvironmentalSensorsIndexread-onlymandatorySensor Index for Environemntal table
1.3.6.1.4.1.4779.1.6.2.1.4ColumnsRPCEnvironmentalTyperead-onlymandatoryEnvironmental Object Type.
1.3.6.1.4.1.4779.1.6.2.1.5ColumnsRPCEnvironmentalNameread-writemandatoryThe name for the environmental object.
1.3.6.1.4.1.4779.1.6.2.1.6ColumnsRPCEnvironmentalMeasurementread-onlymandatoryThe measurement or state for the object.
1.3.6.1.4.1.4779.1.6.2.1.7ColumnsRPCEnvironmentalHiThresholdread-writemandatoryHi threshold for object.
1.3.6.1.4.1.4779.1.6.2.1.8ColumnsRPCEnvironmentalLoThresholdread-writemandatoryLo threshold for object.
1.3.6.1.4.1.4779.1.6.2.1.9ColumnsRPCEnvironmentalMaxread-writemandatoryMax value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.2.1.10ColumnsRPCEnvironmentalMinread-writemandatoryMin value recorded for object since last reset.
1.3.6.1.4.1.4779.1.6.2.1.11ColumnsRPCEnvironmentalHiThresholdEnread-writemandatoryHi threshold enable for object.
1.3.6.1.4.1.4779.1.6.2.1.12ColumnsRPCEnvironmentalLoThresholdEnread-writemandatoryLo threshold enable for object.
1.3.6.1.4.1.4779.1.6.2.1.13ColumnsRPCEnvironmentalStateTrapEnread-writemandatoryTrap enable for environmental sensors with contacts.
1.3.6.1.4.1.4779.1.6.3ScalarsBTAEnvironmentalAllTemperatureSensorsHiThresholdread-writemandatoryHi Threshold for all temperature sensors.
1.3.6.1.4.1.4779.1.6.4ScalarsBTAEnvironmentalAllTemperatureSensorsLoThresholdread-writemandatoryLo Threshold for all temperature sensors.
1.3.6.1.4.1.4779.1.6.5ScalarsBTAEnvironmentalAllTemperatureSensorsHiThresholdTrapEnableread-writemandatoryHi Threshold trap enable for all temperature sensors.
1.3.6.1.4.1.4779.1.6.6ScalarsBTAEnvironmentalAllTemperatureSensorsLoThresholdTrapEnableread-writemandatoryLo Threshold trap enable for all temperature sensors.
1.3.6.1.4.1.4779.1.6.7ScalarsBTAEnvironmentalAllSensorsStateTrapEnableread-writemandatoryState change environmental sensor (ex: contact) trap enable.
1.3.6.1.4.1.4779.2NodecommunicationEstablishedINFORMATION: Communication with the unit has been established. Argument is timeTicks when communication was established.
1.3.6.1.4.1.4779.3Nodemtrapargs
1.3.6.1.4.1.4779.3NodeoutletOnWARNING: The specified RPC outlet has turned on. If sBTAOutletIndex equals zero, then all outlets have turned on.
1.3.6.1.4.1.4779.3.1ScalarmtrapargsIntegerread-onlymandatoryThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.2ScalarmtrapargsIpAddressread-onlymandatoryThis OID allows bayteh traps to be sent with an IP address argument that may not be defined in the baytech MIB. A get of this OID will return 0.0.0.0.
1.3.6.1.4.1.4779.3.3ScalarmtrapargsStringread-onlymandatoryThis OID allows baytech traps to be sent with an octet string argument that may not be defined in the baytech MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.4779.3.4ScalarmtrapargsGaugeread-onlymandatoryThis OID allows baytech traps to be sent with a Gauge argument that may not be defined in the baytech MIB. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.5ScalarmtrapargsTimeTicksread-onlymandatoryThis OID allows baytech traps to be sent with a TimeTicks argument that may not be defined in the baytech MIB. A get of this OID will return 0.
1.3.6.1.4.1.4779.3.6ScalarsBTAModuleIndexread-onlymandatoryThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific DS module. Value w…
1.3.6.1.4.1.4779.3.7ScalarsBTAOutletIndexread-onlymandatoryThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS mod…
1.3.6.1.4.1.4779.3.8ScalarsBTAPortIndexread-onlymandatoryThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS mod…
1.3.6.1.4.1.4779.3.9ScalarsBTAVoltageSourceread-writemandatoryThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the voltage so…
1.3.6.1.4.1.4779.3.10ScalarsBTASourceSwitchCountread-onlymandatoryThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the number of …
1.3.6.1.4.1.4779.3.11ScalarsBTASensorIndexread-onlymandatoryThis OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific sensor in a DS mod…
1.3.6.1.4.1.4779.3.12ScalarsBTABreakerIndexread-onlymandatoryThis is an object which is sent along with a trap to designate a breaker number pertinent to a particular trap. This value will range from 1 to the total numbe…
1.3.6.1.4.1.4779.4NodeoutletOffWARNING: The specified RPC outlet has turned off. If sBTAOutletIndex equals zero, then all outlets have turned off.
1.3.6.1.4.1.4779.5NodeoutletRebootWARNING: The specified RPC outlet has rebooted. If sBTAOutletIndex equals zero, then all outlets have rebooted.
1.3.6.1.4.1.4779.6NodeoutletLockedWARNING: The specified RPC outlet has been locked. If sBTAOutletIndex equals zero, then all outlets have been locked.
1.3.6.1.4.1.4779.7NodeoutletUnlockedWARNING: The specified RPC outlet has been unlocked. If sBTAOutletIndex equals zero, then all outlets have been unlocked.
1.3.6.1.4.1.4779.8NodeconfigChangeSNMPWARNING: The SNMP configuration has been changed.
1.3.6.1.4.1.4779.9NodeconfigChangeOutletWARNING: The specified outlet has changed configuration.
1.3.6.1.4.1.4779.10NodeaccessViolationConsoleWARNING: Someone has attempted to login via the console with the incorrect password.
1.3.6.1.4.1.4779.11NodeaccessViolationNetworkWARNING: Someone has attempted to login via the network with the incorrect password.
1.3.6.1.4.1.4779.12NodeuserPasswordChangeWARNING: The password for the specified user has been changed.
1.3.6.1.4.1.4779.13NodeuserAddedWARNING: The specified user has been added.
1.3.6.1.4.1.4779.14NodeuserLoggedInINFORMATIONAL: The specified user has logged in.
1.3.6.1.4.1.4779.15NodetemperatureThresholdViolationWARNING: A temperature threshold has been violated. The argument is the rpc index.
1.3.6.1.4.1.4779.16NodetemperatureThresholdViolationClearedINFORMATIONAL: A temperature threshold violated has been cleared. The argument is the rpc index.
1.3.6.1.4.1.4779.17NodecurrentThresholdViolationWARNING: The preset current threshold has been violated. The argument is the rpc index.
1.3.6.1.4.1.4779.18NodecurrentThresholdViolationClearedINFORMATIONAL: A current threshold violation has been cleared. The argument is the rpc index.
1.3.6.1.4.1.4779.19NoderesetModulesEventWARNING: A reset modules (RM) command has been executed.
1.3.6.1.4.1.4779.20NoderesetModulesCompleteWARNING: A reset modules (RM) command has been completed.
1.3.6.1.4.1.4779.21NodeerrorExecutingSNMPCommandWARNING: unable to execute SNMP command. String contains reason and command.
1.3.6.1.4.1.4779.22NodefileTransferCompleteINFORMATIONAL: file transfer to unit complete.
1.3.6.1.4.1.4779.23NodeuserTerminatedWARNING: user terminated. Argument specifies user.
1.3.6.1.4.1.4779.24NodevoltageOverThresholdViolationWARNING: Over voltage. Argument specifies rpc.
1.3.6.1.4.1.4779.25NodevoltageOverThresholdViolationClearedINFORMATIONAL: Over voltage cleared. Argument specifies rpc.
1.3.6.1.4.1.4779.26NodevoltageUnderThresholdViolationWARNING: Under voltage. Argument specifies rpc.
1.3.6.1.4.1.4779.27NodevoltageUnderThresholdViolationClearedINFORMATIONAL: Under voltage cleared. Argument specifies rpc.
1.3.6.1.4.1.4779.28NodecircuitBreakerAlarmWARNING: Circuit breaker is blown. Argument specifies rpc.
1.3.6.1.4.1.4779.29NoderpcFailureAlarmWARNING: Unable to communicate to an RPC. Argument specifies port number of RPC.
1.3.6.1.4.1.4779.30NodeuserDeletedINFORMATIONAL: The specified user has logged in.
1.3.6.1.4.1.4779.31NodewarningThresholdViolation
1.3.6.1.4.1.4779.32NodewarningThresholdViolationClear
1.3.6.1.4.1.4779.33NodeemergencyThresholdViolation
1.3.6.1.4.1.4779.34NodeemergencyThresholdViolationClear
1.3.6.1.4.1.4779.35NodecircuitBreakerAlarmClearTrapCircuit breaker has been reset. Argument specifies rpc.
1.3.6.1.4.1.4779.36NodecurrentUnderThresholdViolationWARNING: Low current. Argument specifies rpc.
1.3.6.1.4.1.4779.37NodecurrentUnderThresholdViolationClearedINFORMATIONAL: Low current cleared. Argument specifies rpc.
1.3.6.1.4.1.4779.38NodevoltageSourceChangeAlarmWARNING: RPC voltage source has changed. Arguments specify modules index, current voltage source, and count of number of times source has been switched.
1.3.6.1.4.1.4779.39NodesensorTempThreshHiAlarmTrapWARNING: Hi threshold exceeded. Arguments specify module, sensor number
1.3.6.1.4.1.4779.40NodesensorTempThreshHiAlarmClearedTrapWARNING: Hi threshold alarm cleared. Arguments specify module, sensor number
1.3.6.1.4.1.4779.41NodesensorTempThreshLoAlarmTrapWARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
1.3.6.1.4.1.4779.42NodesensorTempThreshLoAlarmClearedTrapWARNING: Lo threshold alarm cleared. Arguments specify module, sensor number
1.3.6.1.4.1.4779.43NodesensorStateChangeTrapWARNING: Sensor state (contact, detector, etc) has changed. Arguments specify module, sensor number
1.3.6.1.4.1.4779.44NodeconfigChangeSensorWARNING: The specified environmental sensor has changed configuration.
1.3.6.1.4.1.4779.45NodesensorTypeChangeWARNING: The specified environmental sensor is now a different type.