MIB Viewer

CAMBIUM-NETWORKS-CABLE-DIAG-MIB

19 objects
This MIB module contains objects related to the cable diagnostics support.
Imported Objects
IF-MIBifIndex
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCRowStatus TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.17713.24.7IdentitycnCableDiagMibThis MIB module contains objects related to the cable diagnostics support.
1.3.6.1.4.1.17713.24.7.0NodecnCableDiagObjects
1.3.6.1.4.1.17713.24.7.0.1TablecnCableDiagPortTablenot-accessiblecurrentA table of por-port entries containing control and status information related to cable diagnostics
1.3.6.1.4.1.17713.24.7.0.1.1RowcnCableDiagPortEntrynot-accessiblecurrentPer-port entry for control and status information related to cable diagnostics
1.3.6.1.4.1.17713.24.7.0.1.1.1ColumncnCableDiagPortIndexnot-accessiblecurrentThis object uniquely defines the ethernet port index
1.3.6.1.4.1.17713.24.7.0.1.1.2ColumncnCableDiagTestResultPair1read-onlycurrentThis object uniquely identifies the results of the cable diagnostics test
1.3.6.1.4.1.17713.24.7.0.1.1.3ColumncnCableDiagTestResultPair2read-onlycurrentThis object uniquely identifies the results of the cable diagnostics test
1.3.6.1.4.1.17713.24.7.0.1.1.4ColumncnCableDiagTestResultPair3read-onlycurrentThis object uniquely identifies the results of the cable diagnostics test
1.3.6.1.4.1.17713.24.7.0.1.1.5ColumncnCableDiagTestResultPair4read-onlycurrentThis object uniquely identifies the results of the cable diagnostics test
1.3.6.1.4.1.17713.24.7.0.1.1.6ColumncnCableDiagFaultLengthPair1read-onlycurrentThis object uniquely identifies the length at which the fault occurs
1.3.6.1.4.1.17713.24.7.0.1.1.7ColumncnCableDiagFaultLengthPair2read-onlycurrentThis object uniquely identifies the length at which the fault occurs
1.3.6.1.4.1.17713.24.7.0.1.1.8ColumncnCableDiagFaultLengthPair3read-onlycurrentThis object uniquely identifies the length at which the fault occurs
1.3.6.1.4.1.17713.24.7.0.1.1.9ColumncnCableDiagFaultLengthPair4read-onlycurrentThis object uniquely identifies the length at which the fault occurs
1.3.6.1.4.1.17713.24.7.0.1.1.10ColumncnCableDiagTimeStampread-onlycurrentThis object uniquely identifies the UNIX time stamp of the last successfull test
1.3.6.1.4.1.17713.24.7.0.1.1.11ColumncnCableDiagStartTestread-writecurrentThis object starts the cable diagnostics cable tester. For reading results use other objects.
1.3.6.1.4.1.17713.24.7.0.1.1.12ColumncnCableDiagLengthPair1read-onlycurrentThis object representes the length of a normal cable
1.3.6.1.4.1.17713.24.7.0.1.1.13ColumncnCableDiagLengthPair2read-onlycurrentThis object representes the length of a normal cable
1.3.6.1.4.1.17713.24.7.0.1.1.14ColumncnCableDiagLengthPair3read-onlycurrentThis object representes the length of a normal cable
1.3.6.1.4.1.17713.24.7.0.1.1.15ColumncnCableDiagLengthPair4read-onlycurrentThis object representes the length of a normal cable