MIB Viewer

CENTRECOM-MIB

93 objects
Atkk Switch System objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.207Nodeati
1.3.6.1.4.1.207.1Nodeproducts
1.3.6.1.4.1.207.1.4NodecentreCom
1.3.6.1.4.1.207.1.4.16Nodecentrecom8500sx
1.3.6.1.4.1.207.1.4.17Nodecentrecom8500lx
1.3.6.1.4.1.207.1.4.18Nodecentrecom9100sx
1.3.6.1.4.1.207.1.4.19Nodecentrecom9100lx
1.3.6.1.4.1.207.8NodemibObjects
1.3.6.1.4.1.207.8.12NodeatkkSwitchMIB
1.3.6.1.4.1.207.8.12.2NodeextSwitchMIB
1.3.6.1.4.1.207.8.12.2.3IdentityatiSwitchSystemAtkk Switch System objects
1.3.6.1.4.1.207.8.12.2.3.3ScalaratiSaveConfigurationwrite-onlymandatoryWhen this object is set, the device will copy the contents of the configuration database to a buffer and save it to the persistant store specified by the value…
1.3.6.1.4.1.207.8.12.2.3.4ScalaratiSaveStatusread-onlymandatoryThis object will return the status of a save operation invoked by setting the atiSaveConfiguration object. A network management application can read this objec…
1.3.6.1.4.1.207.8.12.2.3.5ScalaratiCurrentConfigInUseread-onlymandatoryShows which NVRAM configuration store was used at last boot
1.3.6.1.4.1.207.8.12.2.3.6ScalaratiConfigToUseOnRebootread-writemandatoryControls which NVRAM configuration store will be used on next reboot.
1.3.6.1.4.1.207.8.12.2.3.7ScalaratiOverTemperatureAlarmread-onlymandatoryAlarm status of overtemperature sensor in device enclosure.
1.3.6.1.4.1.207.8.12.2.3.8ScalaratiCurrentTemperatureread-onlymandatoryCurrent temperature in degrees celcius measured inside device enclosure.
1.3.6.1.4.1.207.8.12.2.3.9TableatiFanStatusTablenot-accessiblemandatoryTable of operational status of all internal cooling fans.
1.3.6.1.4.1.207.8.12.2.3.9.1RowatiFanStatusEntrynot-accessiblemandatoryEntry in table of all internal cooling fans.
1.3.6.1.4.1.207.8.12.2.3.9.1.1ColumnatiFanNumberread-onlymandatoryIdentifier of cooling fan, numbered from the front and/or left side of device.
1.3.6.1.4.1.207.8.12.2.3.9.1.2ColumnatiFanOperationalread-onlymandatoryOperational status of a cooling fan.
1.3.6.1.4.1.207.8.12.2.3.10ScalaratiPrimaryPowerOperationalread-onlymandatoryOperational status of internal power supply of a device.
1.3.6.1.4.1.207.8.12.2.3.11ScalaratiRedundantPowerStatusread-onlymandatoryOperational status of an external redundant power supply to a device.
1.3.6.1.4.1.207.8.12.2.3.12ScalaratiRedundantPowerAlarmread-onlymandatoryAlarm state of an external redundant power supply to a device. Alarm state indicates either fan failure or overtemperature condition.
1.3.6.1.4.1.207.8.12.2.3.13ScalaratiPrimarySoftwareRevread-onlymandatoryThe software revision of the primary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This …
1.3.6.1.4.1.207.8.12.2.3.14ScalaratiSecondarySoftwareRevread-onlymandatoryThe software revision of the secondary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. Thi…
1.3.6.1.4.1.207.8.12.2.3.15ScalaratiImageToUseOnRebootread-writemandatoryControls which image will be used on next reboot.
1.3.6.1.4.1.207.8.12.2.3.16ScalaratiSystemIDread-onlymandatoryThis represents the System ID of the Switch.
1.3.6.1.4.1.207.8.12.2.3.17ScalaratiSystemBoardIDread-onlymandatoryThis represents the Board ID of the Switch.
1.3.6.1.4.1.207.8.12.2.3.18ScalaratiSystemLeftBoardIDread-onlymandatoryThis represents the Left Board ID of the Summit Switch.
1.3.6.1.4.1.207.8.12.2.3.19ScalaratiSystemRightBoardIDread-onlymandatoryThis represents the Right Board ID of the Summit Switch.
1.3.6.1.4.1.207.8.12.2.4IdentityatiVlanAtkk Virtual LAN objects
1.3.6.1.4.1.207.8.12.2.4.1NodeatiVlanGroup
1.3.6.1.4.1.207.8.12.2.4.1.2TableatiVlanIfTablenot-accessiblemandatoryThis table lists VLAN interfaces that exist within a device. A single entry exists in this list for each VLAN interface in the system. A VLAN interface may be …
1.3.6.1.4.1.207.8.12.2.4.1.2.1RowatiVlanIfEntrynot-accessiblemandatoryAn individual VLAN interface entry. When an NMS wishes to create a new entry in this table, it must obtain a non-zero index from the atiNextAvailableVirtIfInde…
1.3.6.1.4.1.207.8.12.2.4.1.2.1.1ColumnatiVlanIfIndexread-writemandatoryThe index value of this row and the vlan's ifIndex in the ifTable. The NMS obtains the index value for this row by reading the atiNextAvailableVirtIfIndex obje…
1.3.6.1.4.1.207.8.12.2.4.1.2.1.2ColumnatiVlanIfDescrread-writemandatoryThis is a description of the VLAN interface.
1.3.6.1.4.1.207.8.12.2.4.1.2.1.3ColumnatiVlanIfTyperead-writemandatoryThe VLAN interface type.
1.3.6.1.4.1.207.8.12.2.4.1.2.1.4ColumnatiVlanIfGlobalIdentifierread-writemandatoryAn administratively assigned global VLAN identifier. The binding between a global identifier and a VLAN interface can be created or removed. To create a bindin…
1.3.6.1.4.1.207.8.12.2.4.1.2.1.6ColumnatiVlanIfStatusread-writemandatoryThe status column for this VLAN interface. This OBJECT can be set to: active(1) createAndGo(4) createAndWait(5) destroy(6) The following values may be read: ac…
1.3.6.1.4.1.207.8.12.2.4.2NodeatiVirtualGroup
1.3.6.1.4.1.207.8.12.2.4.2.1ScalaratiNextAvailableVirtIfIndexread-onlymandatoryThe value of the next available virtual ifIndex. This object is used by an NMS to select an index value for row-creation in tables indexed by ifIndex. The curr…
1.3.6.1.4.1.207.8.12.2.4.3NodeatiEncapsulationGroup
1.3.6.1.4.1.207.8.12.2.4.3.1TableatiVlanEncapsIfTablenot-accessiblemandatoryThis table lists VLAN encapsulation interfaces that exist within a device. A single entry exists in this list for each VLAN encapsulation interface in the syst…
1.3.6.1.4.1.207.8.12.2.4.3.1.1RowatiVlanEncapsIfEntrynot-accessiblemandatoryAn individual VLAN encapsulation interface entry. When an NMS wishes to create a new entry in this table, it must obtain a non-zero index from the atiNextAvail…
1.3.6.1.4.1.207.8.12.2.4.3.1.1.1ColumnatiVlanEncapsIfIndexread-writemandatoryThe index value of this row and the encapsulation interface's ifIndex in the ifTable. The NMS obtains the index value used for creating a row in this table by …
1.3.6.1.4.1.207.8.12.2.4.3.1.1.2ColumnatiVlanEncapsIfTyperead-writemandatoryThe encapsulation algorithm used when encapsulating packets transmitted, or de-encapsulating packets received through this interface.
1.3.6.1.4.1.207.8.12.2.4.3.1.1.3ColumnatiVlanEncapsIfTagread-writemandatoryThe tag used when encapsulating packets transmitted, or de-encapsulating packets received through this interface.
1.3.6.1.4.1.207.8.12.2.4.3.1.1.4ColumnatiVlanEncapsIfStatusread-writemandatoryThe row status for this VLAN encapsulation interface. This OBJECT can be set to: active(1) createAndGo(4) createAndWait(5) destroy(6) The following values may …
1.3.6.1.4.1.207.8.12.2.4.5NodeatiProtocolGroup
1.3.6.1.4.1.207.8.12.2.4.5.1TableatiVlanProtocolTablenot-accessiblemandatoryTable of defined combinations of protocol IDs that make up one protocol definition name. All members of one protocol definition share the same atiVlanProtocolI…
1.3.6.1.4.1.207.8.12.2.4.5.1.1RowatiVlanProtocolEntrynot-accessiblemandatoryOne member protocol ID of a protocol definition.
1.3.6.1.4.1.207.8.12.2.4.5.1.1.1ColumnatiVlanProtocolIndexread-writemandatoryAn index representing a protocol grouping of protocol ID values. A limited number of protocol groupings may be defined (up to 7).
1.3.6.1.4.1.207.8.12.2.4.5.1.1.2ColumnatiVlanProtocolIdIndexread-writemandatoryAn index representing a particular protocol ID within a protocol grouping. A limited number of protocol IDs may be defined per atiVlanProtocolIndex (up to 6).
1.3.6.1.4.1.207.8.12.2.4.5.1.1.3ColumnatiVlanProtocolNameread-writemandatoryA human-readable string representing this protocol. This string should be the same for all entries sharing a given atiVlanProtocolIndex. A atiVlanProtocolEntry…
1.3.6.1.4.1.207.8.12.2.4.5.1.1.4ColumnatiVlanProtocolDllEncapsTyperead-writemandatoryRepresents the type of data-link encapsulation in which the atiVlanProtocolId protocol ID is carried. The value any(1) is used to indicate a wildcard and match…
1.3.6.1.4.1.207.8.12.2.4.5.1.1.5ColumnatiVlanProtocolIdread-writemandatoryThe protocol ID: for entries of type ethertype(2) or llcSnapEthertype(4) this represents a 16-bit protocol ID. For entries of type llc(3) it represents a conca…
1.3.6.1.4.1.207.8.12.2.4.5.1.1.6ColumnatiVlanProtocolStatusread-writemandatoryThe row status variable, used according to row installation and removal conventions.
1.3.6.1.4.1.207.8.12.2.4.5.2TableatiVlanProtocolVlanTablenot-accessiblemandatoryTable to apply one of the protocol definitions in atiVlanProtocolTable to a given VLAN This applies to all ports that are untagged in this VLAN). A limited num…
1.3.6.1.4.1.207.8.12.2.4.5.2.1RowatiVlanProtocolVlanEntrynot-accessiblemandatoryA mapping of untagged packets of one protocol onto a particular VLAN.
1.3.6.1.4.1.207.8.12.2.4.5.2.1.1ColumnatiVlanProtocolVlanIfIndexread-writemandatoryThe index value of this row and the vlan's ifIndex in the ifTable. The NMS obtains the index value for this row by reading the atiNextAvailableVirtIfIndex obje…
1.3.6.1.4.1.207.8.12.2.4.5.2.1.2ColumnatiVlanProtocolVlanProtocolIndexread-writemandatoryAn index representing a protocol grouping of protocol ID values. A limited number of protocol groupings may be defined (up to 7).
1.3.6.1.4.1.207.8.12.2.4.5.2.1.3ColumnatiVlanProtocolVlanStatusread-writemandatoryThe row status variable, used according to row installation and removal conventions.
1.3.6.1.4.1.207.8.12.2.5IdentityatiQosAtkk Quality-of-Service objects
1.3.6.1.4.1.207.8.12.2.5.1NodeatiQosCommon
1.3.6.1.4.1.207.8.12.2.5.1.4ScalaratiQosModeread-writemandatoryIndicates which QoS mode the device should use. ingress(1) applies priority-based QoS based on the incoming packet's destination IP or MAC address, 802.1p prio…
1.3.6.1.4.1.207.8.12.2.5.1.5ScalaratiQosUnconfigureread-writemandatorySetting this to true will reset all QoS settings in the device to factory defaults. Reads from this value return an undefined value.
1.3.6.1.4.1.207.8.12.2.5.1.6TableatiQosProfileTablenot-accessiblemandatoryThis table lists QoS profiles.
1.3.6.1.4.1.207.8.12.2.5.1.6.1RowatiQosProfileEntrynot-accessiblemandatoryAn individual QoS profile Entry.
1.3.6.1.4.1.207.8.12.2.5.1.6.1.1ColumnatiQosProfileIndexread-writemandatoryAn index that uniquely identifies an entry in the qos table.
1.3.6.1.4.1.207.8.12.2.5.1.6.1.2ColumnatiQosProfileNameread-writemandatoryA unique qos profile name.
1.3.6.1.4.1.207.8.12.2.5.1.6.1.3ColumnatiQosProfileMinBwread-writemandatoryThe minumum percentage of bandwidth that this queue requires. The Switch is required to provide the minumum amount of bandwidth to the queue. The lowest possib…
1.3.6.1.4.1.207.8.12.2.5.1.6.1.4ColumnatiQosProfileMaxBwread-writemandatoryThe maximum percentage of bandwidth that this queue is permitted to use
1.3.6.1.4.1.207.8.12.2.5.1.6.1.5ColumnatiQosProfilePriorityread-writemandatoryThe level of priority in which this queue will be serviced by the Switch.
1.3.6.1.4.1.207.8.12.2.5.1.6.1.6ColumnatiQosProfileRowStatusread-writemandatoryThe status of the atiQosProfile entry. This OBJECT can be set to: active(1) createAndGo(4) createAndWait(5) destroy(6) The following values may be read: active…
1.3.6.1.4.1.207.8.12.2.5.1.7TableatiQosByVlanMappingTablenot-accessiblemandatoryTable to associate a Vlan with the QoS profile that the Vlan is using. Every Vlan is assigned a Qos Profile and hence there is an entry in this table correspon…
1.3.6.1.4.1.207.8.12.2.5.1.7.1RowatiQosByVlanMappingEntrynot-accessiblemandatoryThe QoS associated with a particular Vlan.
1.3.6.1.4.1.207.8.12.2.5.1.7.1.1ColumnatiQosByVlanMappingQosProfileIndexread-writemandatoryValue of atiQosProfileIndex that uniquely identifies a QoS Profile entry in atiQosProfileTable. This indicates the QoS to be given to traffic for this Vlan in …
1.3.6.1.4.1.207.8.12.2.6IdentityatiPortAtkk network port objects
1.3.6.1.4.1.207.8.12.2.6NodeoverheatA overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has sufficiently cooled such th…
1.3.6.1.4.1.207.8.12.2.6.1TableatiPortLoadshareTablenot-accessiblemandatoryA table of bindings between a master port and its load-sharing slaves: create/delete entries here to add/delete a port to/from a load-sharing group. Default is…
1.3.6.1.4.1.207.8.12.2.6.1.1RowatiPortLoadshareEntrynot-accessiblemandatoryA binding between a master port and one of its load-sharing slave ports.
1.3.6.1.4.1.207.8.12.2.6.1.1.1ColumnatiPortLoadshareMasterIfIndexread-writemandatoryThe ifIndex value which identifies the port controlling a loadsharing group of ports which includes atiPortLoadshareSlaveIfIndex.
1.3.6.1.4.1.207.8.12.2.6.1.1.2ColumnatiPortLoadshareSlaveIfIndexread-writemandatoryThe ifIndex value which identifies the port which is a member of a loadsharing group controlled by atiPortLoadshareMasterIfIndex.
1.3.6.1.4.1.207.8.12.2.6.1.1.3ColumnatiPortLoadshareGroupingread-writemandatoryThe Grouping value which identifies if load sharing is in pair or quad.
1.3.6.1.4.1.207.8.12.2.6.1.1.4ColumnatiPortLoadshareStatusread-writemandatoryThe row status variable, used according to row installation and removal conventions.
1.3.6.1.4.1.207.8.12.2.7NodefanfailedA fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation.
1.3.6.1.4.1.207.8.12.2.8NodefanOKA fan has transitioned out of a failure state and is now operating correctly.
1.3.6.1.4.1.207.8.12.2.9NodeinvalidLoginAttemptA user attempted to login to console or by telnet but was refused access due to incorrect username or password
1.3.6.1.4.1.207.8.12.2.10NodepowerSupplyFailOne or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over.
1.3.6.1.4.1.207.8.12.2.11NodepowerSupplyGoodOne or more previously bad sources of power to this agent has come back to life without causing an agent restart.
1.3.6.1.4.1.207.8.12.2.12NoderpsAlarmAttached Redundant Power Supply device is indicating an alarm condition.
1.3.6.1.4.1.207.8.12.2.13NoderpsNoAlarmAttached Redundant Power Supply device is no longer indicating an alarm condition.